29.08.2014 Views

Chip Blaster manual - Salvex

Chip Blaster manual - Salvex

Chip Blaster manual - Salvex

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>Chip</strong>BLASTER, Inc. 57<br />

16.0. PRESSURE ADJUSTMENT PROCEDURE ALTIVAR 31<br />

DRIVES: (Cont.)<br />

16.0.10. Turn the main disconnect on to repower the <strong>Chip</strong>BLASTER unit to alter the<br />

program pressure setting changes to the AFD (Adjustable Frequency Drive).<br />

USE EXTREME CAUTION WHEN WORKING ON LIVE<br />

EQUIPMENT.<br />

16.0.11. FOR ALTIVAR 31 DRIVES without setpoints - Adjust the PID setpoint as<br />

follows:<br />

16.0.11.1. At the rdY promp on the display PRESS ENT. SEt will be displayed.<br />

16.0.11.2.Press ENT. rPI will be displayed.<br />

16.0.11.3.Press ENT, 50.0 will be displayed.<br />

16.0.11.4. Press the up or down arrow keys as required to change hertz setting<br />

of the drive. Decreasing the hertz setting will reduce the output<br />

pressure like wise increasing the hertz setting will increase the output<br />

pressure. Do not exceed the maximum pressure rating of the<br />

machine tool.<br />

16.0.11.5. When the revised pressure setting is reached (indicated on the high<br />

pressure gauge) PRESS ENT.<br />

16.0.11.6. PRESS ESC three times to return to the rdy screen.<br />

NOTE:<br />

-Lowering the setpoint will decrease the output pressure.<br />

-Raising the setpoint will increase the output pressure.<br />

To view the load on the motor:<br />

With display showing rdY.<br />

Press ENT display will show Set.<br />

Press the “DOWN” arrow three times until SUP is displayed.<br />

Display will show FrH.<br />

Press the “DOWN” arrow key four times until LCr is displayed.<br />

This will display the motor current in amps.<br />

To return to the rdY display press ESC.<br />

DO NOT PRESS ENT.<br />

16.0.11.7. Test run the machine and check the output pressure on the high -<br />

pressure gauge and make the necessary adjustments to achieve the<br />

desired working pressure.<br />

16.0