<strong>Chip</strong>BLASTER, Inc. 55<br />
15.0. TROUBLESHOOTING (Cont.):<br />
15.9. ALTIVAR 31 DRIVE AS SET PARAMETERS 460 VAC W/ and W/O<br />
PRESETS (Cont.):<br />
Code Label Value Default value logical address Menu<br />
R1 Relay R1 Drive fault Drive fault 5001<br />
R2 Relay R2 Not assigned Not assigned 5002<br />
RFC Enable switching refs. Configuration reference 1 Configuration reference 1 8411<br />
RIG<br />
RP2<br />
RP3<br />
RP4<br />
Integral gain PI regulator<br />
2nd PI preset reference<br />
3rd PI preset reference<br />
4th PI preset reference<br />
3.75<br />
ALL MODELS<br />
36.0%<br />
ALL MODELS<br />
24.0%<br />
ALL MODELS<br />
10.0 %<br />
ALL MODELS<br />
1.00 11942<br />
30.0% 11921<br />
60.0% 11922<br />
90.0% 11923<br />
RPG PI Proportional gain 1.50 1.00 11941<br />
RPI Internal PI reference 45.0% 0.0% 11920<br />
RPS Ramp switching Not assigned Not assigned 9010<br />
RPT<br />
RRS<br />
Type of Ramp<br />
Reverse<br />
U-Ramp<br />
ALL MODELS<br />
Not assigned<br />
ALL MODELS<br />
Linear ramp 9004<br />
Logic input Ll2 11105<br />
RSC Cold stator resistance Inactiv. Inactiv. 9643<br />
RSF Fault reset Not assigned Not assigned 7124<br />
SA2 Summing input 2<br />
Not configured<br />
ALL MODELS<br />
Analog input AI2 11801<br />
SA3 Summing input 3 Not configured Not configured 11802<br />
SDC1 DC current at standstill 19.2A 19.2A 10403<br />
SDC2 DC current at standstill 2 9.5A ALL MODELS 9.5A 10405<br />
SDS Display scale factor 30.0 30.0 12001<br />
SFR Drive switching frequency 4.0 kHz 4.0 kHz 3102<br />
SLL Stop mode at Modbus SLF Freewheel Freewheel 7010<br />
SLP Slip Compensation 100% 100 % 9625<br />
SRF Disable speed loop filter No No 9101<br />
STA Frequency loop stability 20% 20% 9621<br />
SIP Ctrld stop on power loss Lock drive freewheel stop Lock drive freewheel stop 7004<br />
sn Normal stop mode On ramp On ramp 11201<br />
TCC 2 wire or 3 wire control 2-wire control 2-wire control 11101<br />
TCT Type of 2 wire control Edge triggered Edge triggered 11102<br />
TDC1 DC injection time 0.5 s O.5"s 10402<br />
TDC2 2nd DC injection time 0.0 s 0.0 s 10404<br />
TFR<br />
Max. output frequency<br />
JV4 & 8 68.0 Hz, EV 75.0 Hz<br />
GV & CV 80.0 Hz<br />
72.0 Hz 3103<br />
TLS Low speed time out O.Os 0.0 s 11701<br />
TNL Auto-tuning fault config. Yes Yes 7012<br />
nD Motor thermal threshold 100% 100 % 11002<br />
TUN Automatic tuning Not assigned Not assigned 9608<br />
UFR Voltage boost 20% 20% 9623<br />
UFT Select type of U/F ratio Sensorless flux vector ctrl Sensorless flux vector ctrl 9607<br />
UNS<br />
Nominal motor voltage<br />
460 V<br />
ALL MODELS<br />
460V 9601<br />
15.9