<strong>Chip</strong>BLASTER, Inc. 52<br />

15.0. TROUBLESHOOTING (Cont.):<br />

15.8. ALTIVAR 31 DRIVE AS SET PARAMETERS 230 VAC W/ and W/O<br />

PRESETS (Cont.):<br />

Code Label Value Default value logical address Menu<br />

R1 Relay R1 Drive fault Drive fault 5001<br />

R2 Relay R2 Not assigned Not assigned 5002<br />

RFC Enable switching refs. Configuration reference 1 Configuration reference 1 8411<br />

RIG<br />

RP2<br />

RP3<br />

RP4<br />

Integral gain PI regulator<br />

2nd PI preset reference<br />

3rd PI preset reference<br />

4th PI preset reference<br />

3.75<br />

ALL MODELS<br />

36.0%<br />

ALL MODELS<br />

24.0%<br />

ALL MODELS<br />

10.0 %<br />

ALL MODELS<br />

1.00 11942<br />

30.0% 11921<br />

60.0% 11922<br />

90.0% 11923<br />

RPG PI Proportional gain 1.50 1.00 11941<br />

RPI Internal PI reference 45.0% 0.0% 11920<br />

RPS Ramp switching Not assigned Not assigned 9010<br />

RPT<br />

RRS<br />

Type of Ramp<br />

Reverse<br />

U-Ramp<br />

ALL MODELS<br />

Not assigned<br />

ALL MODELS<br />

Linear ramp 9004<br />

Logic input Ll2 11105<br />

RSC Cold stator resistance Inactiv. Inactiv. 9643<br />

RSF Fault reset Not assigned Not assigned 7124<br />

SA2 Summing input 2<br />

Not configured<br />

ALL MODELS<br />

Analog input AI2 11801<br />

SA3 Summing input 3 Not configured Not configured 11802<br />

SDC1 DC current at standstill 19.2A 19.2A 10403<br />

SDC2 DC current at standstill 2<br />

13.7 A<br />

ALL MODELS<br />

9.5A 10405<br />

SDS Display scale factor 30.0 30.0 12001<br />

SFR Drive switching frequency 4.0 kHz 4.0 kHz 3102<br />

SLL Stop mode at Modbus SLF Freewheel Freewheel 7010<br />

SLP Slip Compensation 100% 100 % 9625<br />

SRF Disable speed loop filter No No 9101<br />

STA Frequency loop stability 20% 20% 9621<br />

SIP Ctrld stop on power loss Lock drive freewheel stop Lock drive freewheel stop 7004<br />

sn Normal stop mode On ramp On ramp 11201<br />

TCC 2 wire or 3 wire control 2-wire control 2-wire control 11101<br />

TCT Type of 2 wire control Edge triggered Edge triggered 11102<br />

TDC1 DC injection time 0.5 s O.5"s 10402<br />

TDC2 2nd DC injection time 0.0 s 0.0 s 10404<br />

TFR<br />

Max. output frequency<br />

JV4 & 8 68.0 Hz, EV 75.0 Hz<br />

GV & CV 80.0 Hz<br />

72.0 Hz 3103<br />

TLS Low speed time out O.Os 0.0 s 11701<br />

TNL Auto-tuning fault config. Yes Yes 7012<br />

nD Motor thermal threshold 100% 100 % 11002<br />

TUN Automatic tuning Not assigned Not assigned 9608<br />

UFR Voltage boost 20% 20% 9623<br />

UFT Select type of U/F ratio Sensorless flux vector ctrl Sensorless flux vector ctrl 9607<br />

NS Nominal motor voltage 240 V All MODELS 230V 9601<br />