<strong>Chip</strong>BLASTER, Inc. 50<br />

15.0. TROUBLESHOOTING (Cont.):<br />

15.8. ALTIVAR 31 DRIVE AS SET PARAMETERS 230 VAC W/ and W/O<br />

PRESETS:<br />

Code Label Value Default value Logical address Menu<br />

ACC<br />

Acceleration ramp time<br />

1.0 s<br />

ALL MODELS<br />

3.0 s 9001<br />

ADC Automatic DC Injection Yes: DC inj. for adj. time Yes: DC inj. for adj. time 10401<br />

ADCO Drive CANopen address 0 0 6051<br />

AI1A<br />

AI2A<br />

Configuration of AI1<br />

Configuration of AI2<br />

Not configured<br />

ALL MODELS<br />

Configuration reference 1 PI<br />

regulator feedback<br />

ALL MODELS<br />

Configuration reference 1 4821<br />

Summing input 2 4822<br />

AI3A Configuration of AI3 Not configured Not configured 4823<br />

AO1T Configuration of AO1 Configuration 0 - 20 mA Configuration 0 - 20 mA 4601<br />

ATR Automatic restart No No 7122<br />

BDCO CANopen trans. speed 125 kbitls 125 kbitls 6053<br />

BFR<br />

Std. motor frequency<br />

60Hz<br />

ALL MODELS<br />

50 Hz 3015<br />

BLC Brake control Not assigned Not assigned 10001<br />

BRA Decel ramp adaptation Yes Yes 9003<br />

CHP Switching, motor 2 Not assigned Not assigned 8011<br />

CLI Internal current limit 41.2A 41.2A 9201<br />

COL Stop for CANopen fit. COF Freewheel Freewheel 7011<br />

cas Motor power factor 0.85 0.85 9606<br />

CRH3 Value for high speed AI3 20.0 mA 20.0 mA 4444<br />

CRL3 Value for low speed AI3 4.0mA 4.0mA 4434<br />

CTD Motor current detection 27.5 A 27.5 A 11001<br />

DCI DC brake via logic input Not assigned Not assigned 11203<br />

DEC<br />

Deceleration ramp time<br />

0.5 s<br />

ALL MODELS<br />

3.0 s 9002<br />

DO AOC/AOVassignment Not assigned Not assigned 5031<br />

DRN Derating for undervoltage No No 7007<br />

EPL Stop mode at external fit. Freewheel Freewheel 7006<br />

ERCO Error registry CANopen 0 0 6056<br />

ETF External fault Not assigned Not assigned 7131<br />

FBS PI multiplication coef. 1.0 1.0 11903<br />

FLG Frequency loop gain 20% 20% 9620<br />

FLO Forced local mode Not assigned Not assigned 8431<br />

FLR Catch on fly No No 3110<br />

FR1 Configuration reference 1<br />

Analog input AI2<br />

ALL MODELS<br />

Analog input AI1 8413<br />

FR2 Configuration reference 2 Not configured Not configured 8414<br />

FRS Nominal motor frequency 60.0 Hz 60.0 Hz 9602<br />

FRT Ramp 2 switch frequency 0.0 Hz 0.0 Hz 9011<br />

FST Fast stop Not assigned Not assigned 11204<br />

FTD Motor freq. threshold 60.0 Hz 60.0 Hz 11003<br />

HSP<br />

High Speed<br />

68.0 Hz JV4 & 8, 75.0 Hz EV<br />

80.0 Hz GV & CV<br />

60.0 Hz 3104<br />

15.8