29.08.2014 Views

Chip Blaster manual - Salvex

Chip Blaster manual - Salvex

Chip Blaster manual - Salvex

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>Chip</strong>BLASTER, Inc. 45<br />

15.0. TROUBLESHOOTING (Cont.):<br />

15.3. Troubleshooting Flow Chart<br />

TROUBLE SHOOTING FLOW CHART<br />

DO YOU HAVE CORRECT<br />

PRESSURE AT<br />

THE MACHINE TOOL?<br />

DO YOU HAVE PRESSURE<br />

ON <strong>Chip</strong>BLASTER's HIGH<br />

PRESSURE GAUGE?<br />

YES<br />

NO<br />

DO YOU HAVE ANY<br />

PRESSURE ON<br />

<strong>Chip</strong>BLASTER's HIGH<br />

PRESSURE GAUGE?<br />

YES<br />

NO<br />

YES<br />

NO<br />

<strong>Chip</strong>BLASTER IS<br />

OKAY<br />

HIGH PRESSURE<br />

GAUGE NOT<br />

WORKING<br />

IS PRESSURE<br />

HIGHER OR<br />

LOWER<br />

THAN NORMAL?<br />

FAULTY UNLOADER,<br />

BYPASS SOLENOID<br />

NOT WORKING,<br />

BROKEN BELT<br />

HIGHER<br />

LOWER<br />

N/C SOLENOID NOT<br />

WORKING, NOZZLE<br />

PLUGGED WITH CHIPS,<br />

NOZZLE TOO SMALL<br />

IS HIGH PRESSURE<br />

PUMP RUNNING?<br />

YES<br />

NO<br />

NOZZLE OPENING TOO LARGE,<br />

LEAKAGE BETWEEN<br />

<strong>Chip</strong>BLASTER AND<br />

MACHINE TOOL NOZZLE<br />

AFD DRIVE TRIPPED,<br />

CR7 NOT ENERGIZED,<br />

FAULTY AFD DRIVE,<br />

FAULTY MOTOR<br />

Figure 7<br />

15.3