Chip Blaster manual - Salvex
Chip Blaster manual - Salvex
Chip Blaster manual - Salvex
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
<strong>Chip</strong>BLASTER, Inc. 43<br />
Fault Systems Cure<br />
Solenoid Valve Is<br />
No Coolant Flowing Sticking<br />
Replace Solenoid<br />
When High Pressure Is<br />
Operating<br />
Solenoid Coil Is Faulty Replace Coil<br />
Coolant Is Pulsating<br />
From High Pressure<br />
Nozzle<br />
Coolant Continues To<br />
Flow During Tool<br />
Changes(Lathes Only)<br />
Return Pump Not<br />
Operating<br />
Return Pump Coolant<br />
Flow Rate Is Slow<br />
Coolant Is Foaming<br />
High Pressure Pump<br />
Shuts Down After 5<br />
Seconds<br />
High Pressure Pump<br />
Valve Is Sticking<br />
Hose Plugged<br />
CR3 Or CR4 Not<br />
Working<br />
Solenoid (SOL A Or B)<br />
Sticking<br />
MR3 Motor Protector<br />
Tripped Or Not Turned<br />
On<br />
Center Float Sticking<br />
Plugged Inlet<br />
Low On Coolant<br />
<strong>Chip</strong>s Stuck Inside Pump<br />
Vane<br />
Motor Wired In Reverse<br />
Incorrect Coolant<br />
Faulty Optional Low<br />
Pressure Detect Switch<br />
Seals Bad In High<br />
Pressure Pump<br />
Clean Or Replace The Valve<br />
Replace Hose<br />
Check Circuit<br />
Change Solenoid<br />
Reset Breaker<br />
Turn On MR3<br />
Free Up Float<br />
Clean Inlet<br />
Add Coolant<br />
Clean <strong>Chip</strong>s From Inside Pump<br />
Change Motor Rotation<br />
Use Coolant With Anti-Foaming<br />
Agents For High Pressure<br />
Replace Low Pressure Detect<br />
Switch<br />
Change High Pressure Pump<br />
Check For Leaks And Repair<br />
ES Relay Not Energized<br />
System Won't Operate<br />
Motor Overload Trip<br />
AFD Trip<br />
Low Limit Coolant<br />
Circuit Breaker Trip<br />
Loss Of 120VAC<br />
Reset Motor Overload<br />
Reset Power To AFD<br />
Add Coolant<br />
Reset Circuit Breaker<br />
Check Transformer, Reset 3CB<br />
And Or 4CB