<strong>Chip</strong>BLASTER, Inc. 43<br />

Fault Systems Cure<br />

Solenoid Valve Is<br />

No Coolant Flowing Sticking<br />

Replace Solenoid<br />

When High Pressure Is<br />

Operating<br />

Solenoid Coil Is Faulty Replace Coil<br />

Coolant Is Pulsating<br />

From High Pressure<br />

Nozzle<br />

Coolant Continues To<br />

Flow During Tool<br />

Changes(Lathes Only)<br />

Return Pump Not<br />

Operating<br />

Return Pump Coolant<br />

Flow Rate Is Slow<br />

Coolant Is Foaming<br />

High Pressure Pump<br />

Shuts Down After 5<br />

Seconds<br />

High Pressure Pump<br />

Valve Is Sticking<br />

Hose Plugged<br />

CR3 Or CR4 Not<br />

Working<br />

Solenoid (SOL A Or B)<br />

Sticking<br />

MR3 Motor Protector<br />

Tripped Or Not Turned<br />

On<br />

Center Float Sticking<br />

Plugged Inlet<br />

Low On Coolant<br />

<strong>Chip</strong>s Stuck Inside Pump<br />

Vane<br />

Motor Wired In Reverse<br />

Incorrect Coolant<br />

Faulty Optional Low<br />

Pressure Detect Switch<br />

Seals Bad In High<br />

Pressure Pump<br />

Clean Or Replace The Valve<br />

Replace Hose<br />

Check Circuit<br />

Change Solenoid<br />

Reset Breaker<br />

Turn On MR3<br />

Free Up Float<br />

Clean Inlet<br />

Add Coolant<br />

Clean <strong>Chip</strong>s From Inside Pump<br />

Change Motor Rotation<br />

Use Coolant With Anti-Foaming<br />

Agents For High Pressure<br />

Replace Low Pressure Detect<br />

Switch<br />

Change High Pressure Pump<br />

Check For Leaks And Repair<br />

ES Relay Not Energized<br />

System Won't Operate<br />

Motor Overload Trip<br />

AFD Trip<br />

Low Limit Coolant<br />

Circuit Breaker Trip<br />

Loss Of 120VAC<br />

Reset Motor Overload<br />

Reset Power To AFD<br />

Add Coolant<br />

Reset Circuit Breaker<br />

Check Transformer, Reset 3CB<br />

And Or 4CB