Chip Blaster manual - Salvex
Chip Blaster manual - Salvex
Chip Blaster manual - Salvex
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
<strong>Chip</strong>BLASTER, Inc. 42<br />
15.0. TROUBLESHOOTING:<br />
15.1. TROUBLESHOOTING CHART:<br />
FAULT SYMPTOMS CURE<br />
<strong>Chip</strong>blaster Has No<br />
Power<br />
CR1 Or CR3 Not<br />
Energized<br />
High Pressure Motor<br />
Not Operating With<br />
"CALL FOR<br />
COOLANT" (CR1 And<br />
Or CR3) Energized<br />
High Pressure Motor<br />
Running Slow<br />
High Pressure Motor<br />
Running Fast<br />
Cannot Achieve<br />
Required Outlet<br />
Pressure<br />
Disconnect Switch Is Off<br />
Machine Tool Off<br />
Overload Tripped<br />
No Command Voltage<br />
From Machining Center<br />
Faulty Relay<br />
Faulty Transducer<br />
Faulty Solenoid<br />
CR1 Or CR7 Not<br />
Working<br />
ES Relay De-Energized<br />
CR8 Not Working<br />
Faulty Transducer<br />
Faulty Solenoid (Sol A Or<br />
B)<br />
Nozzle To Large<br />
Leak In Pressure Line<br />
Faulty Transducer<br />
Faulty Solenoid<br />
Faulty Unloader<br />
Faulty AFD<br />
Pump Seals Are Bad<br />
Faulty Solenoid<br />
Faulty Unloader<br />
Incorrect Nozzle Size<br />
Unloader Not Set Properly<br />
Faulty AFD<br />
Plugged Or Kinked Hose<br />
Turn On Main Power.<br />
Turn On Disconnect.<br />
Turn On Machine Tool<br />
Correct Problem, Reset Overload<br />
Check Command Voltage<br />
Replace Relay<br />
Changes Transducer<br />
Change Solenoid<br />
Check Circuits<br />
Correct Problem And Press<br />
Reset/Air Purge Pushbutton.<br />
Check CR8 Circuit<br />
Replace Transducer<br />
Replace Solenoid<br />
Replace Nozzle<br />
Repair Leak<br />
Replace Transducer<br />
Replace Solenoid<br />
Check Unloader<br />
Repair AFD<br />
Replace Seals<br />
Replace Solenoid<br />
Check Unloader<br />
Replace Nozzle With A<br />
Recommended Standard Size.<br />
Adjust Unloader<br />
Repair AFD<br />
Replace Coil