14.0. PREVENTATIVE MAINTENANCE: (Cont.):<br />

14.17. FILTER BAG ASSEMBLIES – CHECK FOR LEAKS:<br />

14.17.1. Check inlet and outlet hoses for leaks especially at hose clamps. If leaks are<br />

found replace hoses. THE <strong>Chip</strong>BLASTER MUST BE SHUT DOWN.<br />

14.18. POST FILTER - CHANGING:<br />

!<br />

!<br />

THIS CAN ONLY BE REPLACED WHEN THE <strong>Chip</strong>BLASTER IS SHUT<br />

DOWN.<br />

14.18.1. Change post filter when the filter light is on steady.<br />

14.18.2. Unscrew and remove the post filter when dirty,<br />

14.18.3. Remove gasket if it does not come off with filter.<br />

14.18.4. Fill the new filter with clean coolant before replacing. This will speed up the<br />

purge time. USE THE SUPPLIED GASKET, install in groove in the post filter<br />

mounting base. Screw the filter into place being careful not to cross thread the<br />

filter. If the post filter is equipped with a petcock, open the petcock, and<br />

press the air purge button, (on the electrical panel), to remove air from<br />

the filter. When all of the air is purged from the filter, close the petcock.<br />

14.19. SOCK FILTER - CHANGING:<br />

14.19.1. This can only be replaced when the <strong>Chip</strong>BLASTER is shut down.<br />

14.19.2. To remove, cut or untie the cord holding sock filter in place.<br />

14.19.3. Slide the replacement sock filter in place over the fitting and tie securely.<br />

14.19.4. To reorder sock pre-filters refer to form in SCTION 14.16.13.<br />

14.23. FLOAT SWITCH - CLEANING:<br />

14.23.1. Check float switch rod for build up of particulate material, BE<br />

CAREFUL NOT TO BEND THE ROD.<br />

14.23.2. If float switch barrel has dirt build up inside it will be necessary<br />

to disassemble the switch assembly.<br />

14.23.2.1. Remove the plug from the top using a 3/16” hex key.<br />

14.23.2.2. Unscrew the float bulb from the brass rod.<br />

14.23.2.3. Push the brass rod and magnetic carrier up until the<br />

magnetic carrier can be pulled out of the housing.<br />

14.23.2.4. Clean the barrel of the housing with a round soft bristle<br />

brush.<br />

DO NOT LUBRICATE THE FLOAT ASSEMBLY AS THIS<br />

WILL CAUSE IMPROPER OPERATION.<br />

14.23.3. Re-assemble float switch. BE CAREFUL NOT TO BEND THE<br />

ROD.<br />

14.23.4. Clean the float bulb also.<br />

14.23.5. After cleaning insure the rod moves up and down freely without<br />

any binding.<br />

NOTE: FLOAT STEM CLEANING MAY REQUIRE MORE FREQUENT<br />

CLEANING IF LARGE AMOUNTS OF TRAMP OIL IS PRESENT IN<br />

COOLANT RESERVOIR OR CUTTING OILS ARE USED.