Chip Blaster manual - Salvex
Chip Blaster manual - Salvex
Chip Blaster manual - Salvex
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
<strong>Chip</strong>BLASTER, Inc. 37<br />
14.0. PREVENTATIVE MAINTENANCE (Cont.):<br />
14.16. AUTO CROSS OVER: ("A" filter change while unit is in operation).<br />
14.16.1. Change the filter only when the "CHANGE FILTER LIGHT" is<br />
flashing.<br />
14.16.2. Place the "CHANGE FILTER" key switch in the change filter position.<br />
Remove the key.<br />
14.16.3. Open the "A" filter petcock to make sure there is no pressure coming out of the filter<br />
housing.<br />
14.16.4. If air or coolant is coming out of this valve. DO NOT PROCEED, PLEASE CALL<br />
THE FACTORY FOR ASSISTANCE.<br />
14.16.5. Remove lid and inspect for damage. Be careful not to damage filter<br />
hold down plate, seal or springs. Set lid aside.<br />
14.16.6. Remove optional hydrocyclonic filter (if used) from center of bag.<br />
14.16.7. Pull the filter bag out of the housing. Close the filter air purge petcock.<br />
14.16.8. Install the new filter bag in the housing.<br />
14.16.9. Replace the optional hydrocyclonic filter (if used).<br />
14.16.10. Inspect the O-ring for cracks or tears, replace if damaged.<br />
14.16.11. Inspect filter hold down seal for cracks or tears, replace if damaged.<br />
14.16.12. Replace the filter lid. Make sure the O-ring is in the proper groove before<br />
replacing the lid. Replace the filter lid by setting straight down so that the filter<br />
hold down plate will contact filter bag.<br />
14.16.13. Torque filter lid cap screws to 30 FT LB (41Nm) in a star pattern.<br />
14.16.14. Refer to SECTION 11 START UP FOR FILTER PURGE.<br />
DO NOT CHANGE THE "B" FILTER WHILE THE UNIT IS RUNNING.<br />
THE "B" FILTER IS USED ONLY AS A BACKUP FILTER TANK TO<br />
CHANGE THE "A" FILTER WHILE THE UNIT IS RUNNING.<br />
14.16.11. Both filters can be changed while the unit is shut off.<br />
14.16.12. Refer to SECTION 11 START UP FOR FILTER PURGE after the<br />
filter(s) have been changed.