<strong>Chip</strong>BLASTER, Inc. 31<br />
14.0. PREVENTATIVE MAINTENANCE (Cont.):<br />
14.3.2. OIL CHANGE PROCEDURE (Cont.):<br />
14.3.2.4. After oil is drained from pump reinstall the plug in oil sight<br />
gauge assembly. Torque to 180 In LB. (20 Nm).<br />
BE SURE TO INSPECT NYLON WASHER TO INSURE IT IS<br />
NOT DAMAGED.<br />
!<br />
PROPERLY DISPOSE OF OIL PER LOCAL REGULATIONS.<br />
DO NOT REUSE OIL.<br />
14.3.2.5. Locate High Pressure Pump (p/n 2106) and remove dip stick<br />
(LOCATED AT TOP OF PUMP) Place a small funnel in<br />
dipstick opening.<br />
OIL FILL<br />
CAP<br />
Single pump unit<br />
Refilling pump with MOBIL 1 TRI-<br />
SYNTHETIC 15W-50<br />
NOTE: IN A TWO PUMP<br />
UNIT ONLY ONE PUMP<br />
WILL NEED FILLING AS<br />
FLUID WILL SELF<br />
LEVEL.<br />
14.3