<strong>Chip</strong>BLASTER, Inc. 31<br />

14.0. PREVENTATIVE MAINTENANCE (Cont.):<br />

14.3.2. OIL CHANGE PROCEDURE (Cont.):<br />

14.3.2.4. After oil is drained from pump reinstall the plug in oil sight<br />

gauge assembly. Torque to 180 In LB. (20 Nm).<br />

BE SURE TO INSPECT NYLON WASHER TO INSURE IT IS<br />

NOT DAMAGED.<br />

!<br />

PROPERLY DISPOSE OF OIL PER LOCAL REGULATIONS.<br />

DO NOT REUSE OIL.<br />

14.3.2.5. Locate High Pressure Pump (p/n 2106) and remove dip stick<br />

(LOCATED AT TOP OF PUMP) Place a small funnel in<br />

dipstick opening.<br />

OIL FILL<br />

CAP<br />

Single pump unit<br />

Refilling pump with MOBIL 1 TRI-<br />

SYNTHETIC 15W-50<br />

NOTE: IN A TWO PUMP<br />

UNIT ONLY ONE PUMP<br />

WILL NEED FILLING AS<br />

FLUID WILL SELF<br />

LEVEL.<br />

14.3