<strong>Chip</strong>BLASTER, Inc. 30<br />

14.0. PREVENTATIVE MAINTENANCE (Cont.):<br />

14.3. OIL CHANGE PROCEDURE:<br />

IT IS EXTREMELY IMPORTANT TO DISCONNECT AND LOCKOUT<br />

ANY AND ALL POWER SOURCES BEFORE ANY WORK IS TO BE<br />

PERFORMED ON the <strong>Chip</strong>BLASTER UNIT.<br />

14.3.1. <strong>Chip</strong>BLASTER High-Pressure Pump: Change the crankcase oil every<br />

2000 hours.<br />

USE:<br />

For <strong>Chip</strong>BLASTER Inc. pump 2106 - Mobil 1 fully-synthetic 15W-50.<br />

!<br />

FAILURE TO USE<br />

MOBIL 1 FULLY-SYNTHETIC 15W-50 WILL<br />

VOID YOUR WARRANTY<br />

Other Pumps and Motors: All have sealed bearings, no lubrication is necessary.<br />

14.3.2. Oil Change Procedure.<br />

14. 3.2.1 <strong>Chip</strong><strong>Blaster</strong> High Pressure pump: Change the crankcase oil<br />

every 2000 hrs.<br />

14.3.2.2. Remove accesses panel (use 6mm hex wrench).<br />

Typical access panel<br />

14.3.2.3. Locate OIL SIGHT GAUGE ASSEMBLY and remove plug.<br />

(use 8mm hex wrench). Allow to drain into a container. For a<br />

single pump unit there will be 32 ounces (0.9 liters) for a two<br />

pump unit there will be 64 ounces (1.9 liters). NOTE: In a two<br />

pump unit both pumps will be drained at the same time.<br />

DRAIN<br />

PLUG<br />

LOCATION<br />

14.3