<strong>Chip</strong>BLASTER, Inc. 24<br />
12.0. OPERATION (Cont.):<br />
12.2.4. The RETURN (TRANSFER) PUMP is a separate system but is very important.<br />
It must maintain the levels of the coolant in the <strong>Chip</strong>BLASTER’s coolant tank<br />
and the machining center’s coolant tank. The return pump returns coolant from<br />
the machining center’s sump to the <strong>Chip</strong>BLASTER’s coolant tank. The float<br />
assembly in the <strong>Chip</strong>BLASTER’s coolant tank will maintain all coolant levels<br />
including the machining center’s sump.<br />
12.2.5. If the <strong>Chip</strong>BLASTER is to operated from a CENTRAL COOLANT SUPPLY<br />
the <strong>Chip</strong>BLASTER will be supplied with a fill solenoid valve and regulator in<br />
place of a return pump. The fill solenoid will operate based on the float<br />
assembly in the <strong>Chip</strong>BLASTER’s coolant tank and will maintain the tank coolant<br />
level. The central supply system must be capable of supplying at least 1.5 times<br />
the flow rate of the <strong>Chip</strong>BLASTER model being used. The supply pressure<br />
should be in the range of 20 to 30 PSIG (1.4 to 2 bar) The maximum particle size<br />
should not exceed 100 micron.<br />
12.2.6. LOW PRESSURE FLOOD is a factory installed feature. It is designed to be<br />
used to supply filtered coolant at 5 gpm (18.9 liters/minute) 35 psig (2.4bar)<br />
maximum. The flow and pressure is dependent on orifice diameter. The low<br />
pressure flood is controlled by a separate maintained “M” code from the machine<br />
tool. The low pressure, as supplied from the factory, is available at coolant outlet<br />
number 1 and/or 2, depending on <strong>Chip</strong>BLASTER model. The low pressure flood<br />
is used to flush parts, tool plates and general chip clearing.<br />
NOTE: If the low pressure flood coolant is in use; high pressure coolant is<br />
not available.<br />
12.2.7. HIGH / LOW PRESSURE is available as a factory option if high pressure<br />
coolant is required from one coolant outlet and low pressure flood coolant is<br />
required from the other coolant outlet at the same time. The low pressure coolant<br />
as supplied from the factory is available, as standard, on coolant outlet number 1.<br />
NOTE: If HIGH/LOW PRESSURE is required for both coolant outlets a second<br />
HIGH/LOW PRESSURE option must be purchased. The low pressure is designed<br />
to be used to supply filtered coolant at 5 gpm (18.9 liters/minute) 35 psig (2.4bar)<br />
maximum. The flow and pressure is dependent on orifice diameter. The low<br />
pressure flood is controlled by a separate maintained “M” code from the machine<br />
tool.<br />
12.2.8. LOW PRESSURE HOSE WASH DOWN is also available as an option to<br />
provide low pressure filtered coolant through a 20’-0” (6 meter)“garden” hose.<br />
Refer to SECTION 27.19 for a complete description of this option.<br />
12.2