ChipBLASTER, Inc. 20 9.0. ELECTRICAL INSTALLATION (Cont.): 9.1. CONTROL INTERFACE EV For Control Interface instructions please refer to The Chipblaster with THINC ® Control Installation Procedure received with the Chipblaster. 9.3. POWER SUPPLY CONNECTIONS: ! REFER TO ChipBLASTER DATA NAMEPLATE FOR CORRECT SUPPLY VOLTAGE. DO NOT EXCEED AMP RATING OF MACHINING CENTER BREAKER IF CONNECTING TO LOAD SIDE. IF CONNECTING TO A MAIN DROP, SIZE DISCONNECT AND WIRE BASED ON INFORMATION SUPPLIED ON THE ChipBLASTER NAMEPLATE. 9.3.1. The EV is supplied from the factory with a 12 pin plug and receptacle. If the receptacle is not used wire L1, L2 and L3 to the line (top) of the main circuit breaker (1CB). Wire the PE from the machining center to the ground terminal in the ChipBLASTER control panel, otherwise connecL1 to terminal 1, L2 to terminal 2 and L3 to terminal 3. Connect PE to the ground terminal of the receptacle. 10.0. START – UP: 10.1. Fill the ChipBLASTER reservoir with clean coolant to within 3” (76 mm) of top. DO NOT OVERFILL. 10.1. If machine tool sump is not full, top off as required. DO NOT OVERFILL. 10.2. If ChipBLASTER’s optional return (transfer) pump is used; the pump must be primed. 10.3.1. Remove the fill line form the inlet of the ChipBLASTER tank. 10.3.2. Fill line with clean coolant. 10.3.3. Manually energize return (transfer) pump motor starter (MR3). 10.3.4. The return (transfer) pump should now pull from machine tool sump. 10.3.5. If pump does not pull fluid from machine tool sump repeat the above steps. 9.7 – 9.8 ! CHECK MOTOR ROTATIONS. PLEASE REFER TO BELOW. ! CHECK FILTER PUMP ROTATION. ROTATION IS CLOCKWISE VIEWED FROM FAN END 9.3 – 9.4 ! ! CHECK MAIN PUMP ROTATION. ROTATION IS COUNTER CLOCKWISE VIEWED FROM THE SHAFT END. CHECK RETURN PUMP ROTATION (IF USED). ROTATION IS CLOCKWISE VIEWED FROM FAN END.

ChipBLASTER, Inc. 21 11.0. SYSTEM AIR PURGE: 11.1. SINGLE FILTER 11.1.1. Open the 1/4” petcock located on both the filter and post filter, so that trapped air can escape both filters. 11.1.2. Press the (RESET / AIR PURGE) push button, to remove the air from the filters. When all of the air has escaped, close the petcocks. This will lower the tank level and start the return (transfer) pump and lower the sump level. Depending on the capacity of the machine tool sump, the lower level will allow the ChipBLASTER high pressure to fill the sump without overflowing the machine tool sump. Unless the sump is completely emptied DO NOT REFILL MACHINE TOOL SUMP. 11.1.3. Start the ChipBLASTER and check for any coolant leaks. 11.1.4. Insure that all electrical circuits are operating correctly. 11.1.5. The coolant outlet pressure is factory preset to run at 1000 PSIG (69 bar), or a customer specified pressure. Refer to Pressure Adjustment Procedure. (Section 16.0).11.0. SYSTEM AIR PURGE (Cont.): 11.2. DUAL FILTER 11.2.1. Open the 1/4” petcock located on both the filters and post filter, so that trapped air can escape both filters. 11.2.2. Rotate the ball valve handle to the “RUN FILTER A” position. See Figure 4. Figure 4 “Run filter A” 11.2.3. Press the (RESET / AIR PURGE) push button , to remove air from the filter and post filter. When all the air has escaped from the filters close the 1/4” petcock on filter “A”. 11.2.4. Rotate the ball valve handle to the “RUN FILTER B” position. See figure 5. Figure 5 “Run filter B”

<strong>Chip</strong>BLASTER, Inc. 21<br />

11.0. SYSTEM AIR PURGE:<br />

11.1. SINGLE FILTER<br />

11.1.1. Open the 1/4” petcock located on both the filter and post filter, so that trapped air<br />

can escape both filters.<br />

11.1.2. Press the (RESET / AIR PURGE) push button, to remove the air from<br />

the filters. When all of the air has escaped, close the petcocks. This will lower the<br />

tank level and start the return (transfer) pump and lower the sump level.<br />

Depending on the capacity of the machine tool sump, the lower level will allow<br />

the <strong>Chip</strong>BLASTER high pressure to fill the sump without overflowing the<br />

machine tool sump. Unless the sump is completely emptied DO NOT REFILL<br />

MACHINE TOOL SUMP.<br />

11.1.3. Start the <strong>Chip</strong>BLASTER and check for any coolant leaks.<br />

11.1.4. Insure that all electrical circuits are operating correctly.<br />

11.1.5. The coolant outlet pressure is factory preset to run at 1000 PSIG (69 bar), or a<br />

customer specified pressure. Refer to Pressure Adjustment Procedure. (Section<br />

16.0).11.0. SYSTEM AIR PURGE (Cont.):<br />

11.2. DUAL FILTER<br />

11.2.1. Open the 1/4” petcock located on both the filters and post filter, so that trapped air<br />

can escape both filters.<br />

11.2.2. Rotate the ball valve handle to the “RUN FILTER A” position. See Figure 4.<br />

Figure 4<br />

“Run filter A”<br />

11.2.3. Press the (RESET / AIR PURGE) push button , to remove air from the<br />

filter and post filter. When all the air has escaped from the filters close the 1/4”<br />

petcock on filter “A”.<br />

11.2.4. Rotate the ball valve handle to the “RUN FILTER B” position. See figure 5.<br />

Figure 5<br />

“Run filter B”