Chip Blaster manual - Salvex
Chip Blaster manual - Salvex
Chip Blaster manual - Salvex
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
<strong>Chip</strong>BLASTER, Inc. 18<br />
7.0. PLACING A <strong>Chip</strong>BLASTER (Cont.):<br />
Mounting feet installation<br />
Figure 1<br />
Recommended<br />
1 inch (25.4 mm)<br />
EV<br />
!<br />
Upon positioning the unit, go ahead and level the machine. The <strong>Chip</strong>BLASTER must be<br />
level to insure proper operation. Remember the <strong>Chip</strong>BLASTER unit has float switches<br />
and an overflow, if the unit is not level these items may not work properly.<br />
After <strong>Chip</strong>BLASTER is in place and level, remove all items from inside of the tank..<br />
Items located in the tank are: hoses, filter bag(s), and pre-filters. Place all hoses at the<br />
back of the unit (same end as filters).<br />
7.2.10. After you remove everything from inside the tank, you are now ready to either<br />
contact <strong>Chip</strong>BLASTER, Inc. to schedule installation or proceed yourself<br />
depending on your agreement.<br />
!<br />
POWER FOR <strong>Chip</strong>BLASTER MUST BE AVAILABLE BEFORE<br />
SCHEDULING INSTALLATION.<br />
7.0