<strong>Chip</strong>BLASTER, Inc. 110<br />

27.0. OPTIONAL EQUIPMENT (Cont.):<br />

27.21. OPTIONAL DROP IN CHILLER (Cont.):<br />

27.21.8.2. AIR FILTER: Keep Clean<br />

27.21.8.3. CONDENSER: Condenser fins should be cleaned of dust and dirt<br />

regularly.<br />

27.21.8.4. PUMP: See attached pump instructions.<br />

27.21.9. TROUBLE SHOOTING<br />

PROBLEM CAUSE SOLUTION<br />

Cooler operative A. Low Coolant Level Add Coolant<br />

but not cooling B. Dirty Air Filter Clean<br />

C. Blocked Air Flow Remove Blockage<br />

D. Condenser Clogged Clean<br />

E. Faulty Controller Repair/Replace<br />

F. Low Refrigerant Charge Repair *<br />

G. Faulty Compressor Repair/Replace *<br />

H. Faulty Solenoid Valve/ Replace *<br />

Coil<br />

I. Incorrect Expansion Adjust Expansion Valve to proper setting *<br />

Valve setting<br />

Cooler inoperative A. Faulty Power Source Check & Correct<br />

or does not start B. Cooler OFF on Low Check for:<br />

Pressure<br />

Low Coolant Level<br />

No Coolant Flow across the coils<br />

Low Ambient<br />

Wrong Setting on Pressure Switch<br />

Low or Lost Refrigerant Charge *<br />

Incorrect Expansion Valve Setting *<br />

• Actions designated with * should only be done by a Qualified Refrigeration Service Person.<br />