PL1 LED Luminaires<br />
Installation & User’s Manual<br />
Note: For more information on DMX512 networking and systems, refer to "Additional Resources for DMX512" on<br />
page 1. For PL1 LED Luminaire DMX Mapping, refer to "DMX CONTROL" on page 18.<br />
DMX512<br />
(from console or<br />
control device)<br />
DMX512 (out from first<br />
to second luminaire)<br />
See DMX512<br />
Cable Options Below<br />
DMX512 (out to the next luminaire or<br />
DMX512 controlled device)<br />
PL1 LED Luminaires<br />
DMX512 Cable Options<br />
PL1 LED Luminaire DMX Cables (DMX to RJ45)<br />
Sold Separately<br />
To Luminaire (RJ45)<br />
DMX512 (XLR) Male<br />
DMX512 Connections<br />
DMX512 Signal XLR Pin RJ45 Pin<br />
Common (Drain) 1 7<br />
DMX512 - 2 2<br />
DMX512 + 3 1<br />
Note: Remaining pins on each connector are not used.<br />
To Luminaire (RJ45)<br />
DMX512 (XLR) Female<br />
Note: For cables required to operate and control<br />
PL1 LED Luminaires via DMX512, see "PL1<br />
LED Luminaire DMX512 Cables" on page 4.<br />
4. Mounting<br />
There are several ways to mount PL1 LED Luminaires (depending on mounting option purchased). Below are the<br />
various mounting options from Philips <strong>Selecon</strong>. Refer to "Product Descriptions" on page 3 for additional information.<br />
Note: For track mounted luminaires, refer to the track manufacturer’s requirements and instructions for installation<br />
procedures. For ceiling mounted models, you must follow local and national codes for fixture installation.<br />
Mounting 7