Parameter Overview<br />
Operation manual<br />
11<br />
11.3 List of the primary communication parameters<br />
You will need the following parameters when commissioning an inverter on<br />
PROFIBUS:<br />
A00 Save values & start:<br />
When this parameter is activated, the inverter saves the current configuration<br />
and the parameter values in the Paramodule. After po<strong>we</strong>r-off, the inverter starts<br />
with the saved configuration. If the configuration data on the inverter and<br />
Paramodul are identical, only the parameters are saved (speeds up the<br />
procedure).<br />
NOTE<br />
Do not turn off the po<strong>we</strong>r of the control section (device version /L:24V, device<br />
version /H: supply voltage) while the action is being executed. If the po<strong>we</strong>r is<br />
turned off while the action is running this causes incomplete storage. After the<br />
device starts up again the fault "*<strong>Co</strong>nfigStartERROR parameters lost" appears<br />
on the display.<br />
Only several 1000 storage procedures are possible per Paramodul. When this<br />
limit has almost been reached, result 14 is indicated after the storage procedure.<br />
When this happens, replace Paramodul as soon as possible.<br />
Axes: Global<br />
Data type: —<br />
Value: 0, 0, 0<br />
PNU:<br />
2000 hex<br />
Subindex: 3<br />
A83 Busaddress:<br />
Specifies the device address for operation with fieldbus. A83 has no effect on<br />
communication via X3 with POSITool or another USS master.<br />
Axes: Global<br />
Data type: 5<br />
Value: 3<br />
PNU:<br />
2053 hex<br />
Subindex: 1<br />
A84 PROFIBUS Baudrate:<br />
When operated with a device of the 5 th generation of STÖBER inverters with<br />
option board "PROFIBUS DP," the baud rate found on the bus is indicated.<br />
Axes: Global<br />
Data type: 5<br />
Value: 0=9600 Baud, ...<br />
PNU:<br />
2054 hex<br />
Subindex: 1<br />