Switchable scaling Operation manual 10 10 Switchable scaling Some of the device parameters can be scaled for the fieldbus transmission in the process data in two ways: Scaled as standard or with the native raw resolution of the 5th generation of STÖBER inveters. The scaling can be set with the parameter A100. With A100=0, all values are scaled as standard. With A100=1, the raw values are transferred to PROFIBUS. In this case there is no scaling to user-defined or physical units and the values are forwarded in the internal-inverter format instead. This relieves the main processor of the inverter. WE KEEP THINGS MOVING ID 441687.03 32
Parameter Overview Operation manual 11 11 Parameter Overview All parameters of the inverter are available as communication objects via the PKW service (PKW0 or PKW1). 11.1 PROFIDRIVE parameter PNU Subindex Parameter name STÖBER address Data type Value / meaning 918 hex 0 Node address A83 5 Bus address 964 hex 0 Device Identification / Manufacturer — 6 (U16) 267 dez = STÖBER 964 hex 1 Device Identification / Device type 964 hex 2 Device Identification / Version 964 hex 3 Device Identification / Firmware year 964 hex 4 Device Identification / Firmware day / month 965 hex 0 PROFIBUS profilnumber — 6 (U16) 4D44 hex = ASCII "MD" for MDS 5000 — 6 (U16) 0500 hex = V 5.00 — 6 (U16) — — 6 (U16) — — — 0303 hex für PROFIdrive profile version 3 WE KEEP THINGS MOVING ID 441687.03 33
- Page 1 and 2: PROFIBUS Operation manual Fundament
- Page 3 and 4: Table of contents Operation manual
- Page 5 and 6: Introduction Operation manual 1 You
- Page 7 and 8: Notes on Safety Operation manual 2
- Page 9 and 10: Notes on Safety Operation manual 2
- Page 11 and 12: Mounting Operation manual 3 2 Remov
- Page 13 and 14: Mounting Operation manual 3 3.2 Ins
- Page 15 and 16: Mounting Operation manual 3 7 Secur
- Page 17 and 18: Electrical installation Operation m
- Page 19 and 20: Fundamentals of PROFIBUS Operation
- Page 21 and 22: Fundamentals of PROFIBUS Operation
- Page 23 and 24: Bus diagnosis/LEDs Operation manual
- Page 25 and 26: Configuration of the bus system Ope
- Page 27 and 28: Configuration of the bus system Ope
- Page 29 and 30: Prozess data transmission PZD Opera
- Page 31: Control with control and status bit
- Page 35 and 36: Parameter Overview Operation manual
- Page 37 and 38: Parameter Overview Operation manual
- Page 39 and 40: Parameter Overview Operation manual
- Page 41 and 42: Appendix A Operation manual 12 12 A
- Page 43 and 44: Appendix A Operation manual 12 •
- Page 45 and 46: Appendix A Operation manual 12 Erro
- Page 47 and 48: Appendix A Operation manual 12 12.3
- Page 49 and 50: Appendix A Operation manual 12 DPV1
- Page 51 and 52: SPM Appendix B PKW0 telegram Operat
- Page 53 and 54: Appendix B PKW0 telegram Operation
- Page 55 and 56: Global Presence Address registers A
Parameter Overview<br />
Operation manual<br />
11<br />
11 Parameter Overview<br />
All parameters of the inverter are available as communication objects via the<br />
PKW service (PKW0 or PKW1).<br />
11.1 PROFIDRIVE parameter<br />
PNU<br />
Subindex<br />
Parameter name<br />
STÖBER<br />
address<br />
Data<br />
type<br />
Value / meaning<br />
918 hex 0 Node address A83 5 Bus address<br />
964 hex 0 Device<br />
Identification /<br />
Manufacturer<br />
— 6 (U16) 267 dez = STÖBER<br />
964 hex 1 Device<br />
Identification /<br />
Device type<br />
964 hex 2 Device<br />
Identification /<br />
Version<br />
964 hex 3 Device<br />
Identification /<br />
Firmware year<br />
964 hex 4 Device<br />
Identification /<br />
Firmware day /<br />
month<br />
965 hex 0 PROFIBUS<br />
profilnumber<br />
— 6 (U16) 4D44 hex = ASCII<br />
"MD" for MDS 5000<br />
— 6 (U16) 0500 hex = V 5.00<br />
— 6 (U16) —<br />
— 6 (U16) —<br />
— — 0303 hex für<br />
PROFIdrive profile<br />
version 3<br />
WE KEEP THINGS MOVING<br />
ID 441687.03<br />
33