It is important to understand that the operating pressure of the protected equipment should<br />

remain below the reseating pressure of the valve. Most manufacturers and codes and<br />

standards recommend a difference of 3-5% between reseating pressure and operating<br />

pressure to allow proper reseating of the valve and achieve good seat tightness again.<br />

1. Set pressure.<br />

2. Popping pressure.<br />

(over-pressure)<br />

3. Relieving pressure.<br />

4. Max. overpressure.<br />

5. Reseating pressure.<br />

6. Max. blowdown<br />

7. Operating pressure.<br />

Fion Zhang/ Charlie Chong