6.2.14 Reassembly of Valve<br />

it should be reassembled in accordance with the manufacturer’s<br />

instructions.<br />

• The nozzle and disk seating surfaces should not be oiled.<br />

• The spring should be adjusted to pop at set pressure.<br />

• Blowdown rings should be set in accordance with the manufacture’s<br />

recommendations for the appropriate vapor or liquid service.<br />

• the blowdown settings should be noted for future reference.<br />

Most test blocks do not have enough capacity to measure the actual<br />

blowdown, manufacturer’s recommendations and past performance<br />

should be evaluated to estimate any necessary adjustment.<br />