6.2.11 Dismantling of Valve.<br />

Dismantling is not necessary when;<br />

1. Valve has been tested at the appropriate interval ( <strong>API</strong> 510 the<br />

guidance in 6.2.9) for determining the “as received”<br />

2. the results of the “as received” test show that the valve tests<br />

properly<br />

Unless restoration of the valve to the “as new” condition is required.<br />

Pressure relief devices<br />

Five years for typical process services; and<br />

Ten years for clean (non-fouling) and noncorrosive<br />

services.<br />