h. Temperature monitoring system calibrated.<br />

i. Local heating bandwidth is adequate.<br />

j. Insulation applied to the component where required for local heating.<br />

k. Temperature and hold time is correct.<br />

l. Heating rate and cooling rate is correct.<br />

m. Distortion is acceptable after completion of the thermal cycle.<br />

n. Hardness indicates an acceptable heat treatment (see 10.7).<br />

4.4.3.2 Potential inspector actions:<br />

a. Calibrate temperature-monitoring equipment.<br />

b. Correct deficiencies before heat treatment.<br />

c. Repeat the heat treatment cycle.