CABLES FOR OIL INDUSTRY
Any enquiry or questions, please feel free to contact us! www.caledonian-cables.co.uk www.caledonian-tech.net sales6@caledonian-cables.co.uk rose@caledonian-tech.com rose@caledonian-cables.com
Any enquiry or questions, please feel free to contact us!
www.caledonian-cables.co.uk
www.caledonian-tech.net
sales6@caledonian-cables.co.uk
rose@caledonian-tech.com
rose@caledonian-cables.com
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
Caledonian<br />
Cables for Oil Industry<br />
Overall Screened Thermocouple Cable<br />
Special PVC sheath<br />
Positive electrode-nickel-chromium<br />
Negative electrode-nickel-aluminum<br />
PVC insulation<br />
Tinned copper drain wire<br />
Plastic tape<br />
Aluminum tape overall screen<br />
KX Overall Screened Thermocouple Cable<br />
Applications<br />
These cables are used with thermocouples for temperature measurements where hydrocarbon may be<br />
present.<br />
Standards<br />
IEC 60584-3; NF C 42-324<br />
Construction<br />
Conductor: Metal according to thermocouple type<br />
Insulation: PVC<br />
Overall screen: Aluminum/polyester tape with tinned copper drain wire<br />
Sheath: Special PVC. Color depends on thermocouple type<br />
Properties<br />
Flame retardance: NFC 32070 C2, IEC 60332-1-2<br />
Operating voltage: 250V<br />
Operating temperature: -20~60°C<br />
Max. conductor temperature in service: 70°C<br />
Chemical resistance: Aliphatic and aromatic hydrocarbon resistance<br />
mm 2<br />
Conductor Size<br />
Solid or<br />
Stranding<br />
No. of Pairs Min. O.D. (mm) Max. O.D. (mm)<br />
Approx. Weight<br />
(kg/km)<br />
1 14 x 0.30 mm 1 6.3 7.4 70<br />
1.34 1 x 1.30 mm 1 6.3 7.4 75<br />
0.5 1 x 0.8 mm 3 8.0 9.3 95<br />
0.5 1 x 0.8 mm 7 10.5 12.1 165<br />
0.5 1 x 0.8 mm 12 13.3 15.3 255<br />
0.5 1 x 0.8 mm 19 16.5 19.0 380<br />
0.5 1 x 0.8 mm 27 19.2 22.0 510<br />
10<br />
sales@caledonian-cables.co.uk