flue_pipe_accessorie.. - Heatweb
flue_pipe_accessorie.. - Heatweb flue_pipe_accessorie.. - Heatweb
Model microGENUS Model microCombi Model microSYSTEM Model GENUS 27 PLUS 2.1 Connection of the flues for air intake and fume discharge 198 mm 98 mm GENUS - EuroCombi Models Model GENUS 27 PLUS 205 mm 98 mm 198 mm 99 mm Model microGENUS Model microCombi Model microSYSTEM B064 23
3.2 List of Components Key Code Qty DESCRIPTION OF COMPONENT PARTS Design Leq Code Qty = Item Part Number = Quantity in Package Design Leq = Schematic Drawing of the Components = Length Equivalency of the Component 706026 1 H C F C E Leq = 3.3m* Twin Pipe Flue Kit A n°1 Adaptor (ø 60/80mm) for Twin Pipe Systems B n°1 Clamp (ø 100mm) with Seal and Screws C n°5 Silicone Lip O-rings - ø 80mm D n°1 Restrictor (ø 60mm) outer diam. of hole ø 41mm n°1 Restrictor (ø 60mm) outer diam. of hole ø 42mm n°1 Restrictor (ø 60mm) outer diam. of hole ø 47mm E n°290° MF Elbow (ø80) with large radius F n°2 Pipe (ø 80mm) x 1000mm with housing for Lip O-ring H n°1 End Piece for Vent n°1 Instruction Sheet C A D B C F C 705757 1 C Leq = * A * The adaptor is taken into consideration in the value for the maximum length. Adapter (ø 60/80mm) for Twin Pipe Systems A n°1 Adaptor (ø 60/80mm) for Twin Pipe Systems B n°1 Clamp (ø 100mm) with Seal and Screws C n°1 Silicone Lip O-ring - ø 80mm D n°1 Restrictor (ø 60mm) outer diam. of hole ø 42mm n°1 Instruction Sheet B D 24 B064
- Page 1 and 2: INDEX GENUS - EuroCombi Models 1.0
- Page 3 and 4: 1.0 General Information This catalo
- Page 5 and 6: Type B Appliances with Forced Draft
- Page 7 and 8: Table of admissible maximum lengths
- Page 9 and 10: Discharge Type Description Maximum
- Page 11 and 12: 2.1 Insertion of the restrictor on
- Page 13 and 14: 705958 1 Leq = 1 m* E C D B A * F D
- Page 15 and 16: 705790 1 A Leq = 0.5m B Coaxial Ext
- Page 17 and 18: 705724 1 Lead Flashing Red Base Cap
- Page 19 and 20: 3.0 Twin Pipe The diagram shows the
- Page 21 and 22: Discharge Type Description Maximum
- Page 23: No. of Units Description Code F A 1
- Page 27 and 28: 705761 1 Leq = 1m A ø80mm Pipe (10
- Page 29 and 30: 704830 1 Vent Cap Base for Flat Roo
- Page 31 and 32: 705775 1 Must be connected to Code
- Page 33 and 34: 4.0 List of Insulated Components Ke
- Page 35 and 36: 4.1 List of Components for Flue Pip
- Page 37 and 38: Notes: 36 B064
Model microGENUS<br />
Model microCombi<br />
Model microSYSTEM<br />
Model GENUS 27 PLUS<br />
2.1 Connection of the <strong>flue</strong>s for<br />
air intake and fume discharge<br />
198 mm<br />
98 mm<br />
GENUS - EuroCombi Models<br />
Model GENUS 27 PLUS<br />
205 mm<br />
98 mm<br />
198 mm<br />
99 mm<br />
Model microGENUS<br />
Model microCombi<br />
Model microSYSTEM<br />
B064<br />
23