NB: L = L A +L F : The maximum extension is given by the sum of the length of the air intake section and that of the fume discharge section. C 52 types must comply with the following requirements: - The exhaust pipe vent cap must extend at least 0.5 m above the ridge of the roof if it is located on a side other than that for the air intake (this is not obligatory if the exhaust and air intake pipes are located on the same side of the building); • The exhaust and air intake pipes must have the same diameter of ø 80 mm; • The maximum pipe length of the exhaust flue may include a 1 metre section for intake and 16 metres for discharge. 3.1 Installation Examples No. of Units Description Code A 1 Adapter for Twin Pipe Systems 705757 E D B 3 ø80 Pipe 705761 F D B C A C 2 ø80 Elbow (MF90) 705758 D 4 ø80 Cover Plate 705784 E 1 ø80 Stainless Steel Vent Cap 705113 GENUS. model shown F 1 Intake Vent Cap 704738 B064 21
No. of Units Description Code F A 1 Adapter for Twin Pipe Systems 705757 E B 4 ø80 Elbow (MF90) 705758 A C D C 4 ø80 Pipe 705761 D 1 ø80 Flue Bridge 705767 B E 1 Vent Cap/Roof Discharge 705764 GENUS. model shown F 1 Lead Vent Cap Base 704830 2.1 Installation of the restrictor on the air intake side 2.1 Removal of the air intake cap GENUS - EuroCombi Models 22 B064
- Page 1 and 2: INDEX GENUS - EuroCombi Models 1.0
- Page 3 and 4: 1.0 General Information This catalo
- Page 5 and 6: Type B Appliances with Forced Draft
- Page 7 and 8: Table of admissible maximum lengths
- Page 9 and 10: Discharge Type Description Maximum
- Page 11 and 12: 2.1 Insertion of the restrictor on
- Page 13 and 14: 705958 1 Leq = 1 m* E C D B A * F D
- Page 15 and 16: 705790 1 A Leq = 0.5m B Coaxial Ext
- Page 17 and 18: 705724 1 Lead Flashing Red Base Cap
- Page 19 and 20: 3.0 Twin Pipe The diagram shows the
- Page 21: Discharge Type Description Maximum
- Page 25 and 26: 3.2 List of Components Key Code Qty
- Page 27 and 28: 705761 1 Leq = 1m A ø80mm Pipe (10
- Page 29 and 30: 704830 1 Vent Cap Base for Flat Roo
- Page 31 and 32: 705775 1 Must be connected to Code
- Page 33 and 34: 4.0 List of Insulated Components Ke
- Page 35 and 36: 4.1 List of Components for Flue Pip
- Page 37 and 38: Notes: 36 B064
NB: L = L A +L F : The maximum extension is given by the sum of the length of the air intake section and that<br />
of the fume discharge section.<br />
C 52 types must comply with the following requirements:<br />
- The exhaust <strong>pipe</strong> vent cap must extend at least 0.5 m above the ridge of the roof if it is located on a side<br />
other than that for the air intake (this is not obligatory if the exhaust and air intake <strong>pipe</strong>s are located on the<br />
same side of the building);<br />
• The exhaust and air intake <strong>pipe</strong>s must have the same diameter of ø 80 mm;<br />
• The maximum <strong>pipe</strong> length of the exhaust <strong>flue</strong> may include a 1 metre section for intake and 16 metres for<br />
discharge.<br />
3.1 Installation<br />
Examples<br />
No. of<br />
Units<br />
Description<br />
Code<br />
A<br />
1<br />
Adapter for Twin Pipe<br />
Systems<br />
705757<br />
E<br />
D<br />
B 3<br />
ø80 Pipe 705761<br />
F<br />
D<br />
B<br />
C<br />
A<br />
C 2 ø80 Elbow (MF90) 705758<br />
D 4<br />
ø80 Cover Plate 705784<br />
E<br />
1<br />
ø80 Stainless<br />
Steel Vent Cap<br />
705113<br />
GENUS. model shown<br />
F 1<br />
Intake Vent Cap 704738<br />
B064<br />