In System Programming (ISP) for ATMEL chips
In System Programming (ISP) for ATMEL chips
In System Programming (ISP) for ATMEL chips
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
<strong>In</strong> <strong>System</strong> Programmer (<strong>ISP</strong>) <strong>for</strong> <strong>ATMEL</strong> micro controllers<br />
http://www.ikalogic.com/isp.php<br />
Page 22 of 29<br />
26-02-2008<br />
Amit<br />
Reply With Quote<br />
Posted by:<br />
MVS Sarma<br />
on: 15 Nov 2007<br />
Posted by:<br />
amit<br />
on: 26 Nov 2007<br />
Hi Amit, As I understand it byte 4 is DATA ,<br />
if it is read mode itis output from, and if in write mode it is input to, the controller.<br />
the mode is perhaps defined in byte 1<br />
Sarma<br />
Hi,<br />
I am using DB9 connector. reference circuit down.<br />
Reply With Quote<br />
The program Enable instruction on AT89S51 does not shows<br />
0x69 value on MOSI to confirm <strong>Programming</strong> mode enabled.<br />
Can any bodu help?<br />
Vcc o<br />
|<br />
|10 uF<br />
___<br />
___<br />
/ | \\<br />
|<br />
|<br />
| 1.22 KOhms RST<br />
-----------/\\/\\/\\/\\--------------<br />
|<br />
|<br />
|<br />
| Pin 3----------------------------------- MOSI<br />
| Pin 7___________________________________ MISO<br />
/ Pin 8___________________________________ SCK<br />
\\<br />
/9.22 KOhms<br />
\\<br />
/<br />
|<br />
|<br />
|<br />
|<br />
| GND<br />
-----<br />
---<br />
-<br />
Moreover, I am reading 0xff values on alternate byte addresses not on every byte address<br />
after chip erase.<br />
e.g. Address Data<br />
0xfa 00<br />
0xfb 0xff<br />
0xfc 00<br />
and so on, and this is conssitent <strong>for</strong> memory location.<br />
Reply With Quote<br />
Posted by:<br />
mvs sarma<br />
on: 26 Nov 2007<br />
[Quoting: amit] Hi,I am using DB9 connector. reference circuit down.The program Enable<br />
instruction on AT89S51 does not shows0x69 value on MOSI to confirm <strong>Programming</strong> mode<br />
enabled.Can any bodu help?..........Moreover, I am reading 0xff values on alternate byte<br />
addresses not on every byte address after chip erase.e.g. Address Data 0xfa 00 0xfb 0xff<br />
0xfc 00 and so on, and this is conssitent <strong>for</strong> memory location.<br />
Hi, Amit,<br />
you have not mentioned asto which driver software you are using <strong>for</strong> db9 socket and<br />
programming 89S51.<br />
i wonder whether you have written a driver software. if so I would be interested to test it .<br />
Sarma<br />
Reply With Quote