29.07.2014 Views

Submerged Arc Welding Technical Handbook - Esab

Submerged Arc Welding Technical Handbook - Esab

Submerged Arc Welding Technical Handbook - Esab

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

OK Flux 10.50 – Electro slag flux<br />

for vertical up welding<br />

Classification flux Basicity index Density Grain size<br />

Not applicable 2.0 ~ 1.5 kg/dm 3 0.2 - 1.6 mm<br />

Slag type Polarity Alloy transfer<br />

Fluoride-basic<br />

Classification<br />

Wire<br />

Non alloying<br />

Weld metal<br />

OK Autrod EN / AWS EN / AW<br />

12.20 S2 / EM12 Not applicable<br />

12.32 S3Si / EH12K Not applicable<br />

12.34 S3Mo; S MnMo / EA4 Not applicable<br />

12.40 S4 / EH14 Not applicable<br />

Approvals<br />

ABS BV DNV GL LR TÜV DB CE<br />

OK Flux 10.50<br />

with OK Autrod<br />

12.20 x<br />

12.32 x<br />

12.34 x<br />

12.40 x<br />

Typical weld metal chemical composition (%), DC+<br />

C Si Mn Cr Ni Mo Other<br />

With OK Autrod<br />

12.20 0.1 0.1 1.0<br />

12.32 0.1 0.3 1.3<br />

12.34 0.1 0.1 1.0 0.5<br />

12.40 0.1 0.1 1.9<br />

Typical weld metal mechanical properties, DC+<br />

ReL / Rp0.2<br />

(MPa)<br />

Rm<br />

(MPa)<br />

A4 / A5<br />

(%)<br />

CVN<br />

(J at °C)<br />

AW/<br />

SR<br />

Remarks<br />

With OK Autrod +20<br />

12.20 300 420 26 70 AW welded in steel<br />

with ReL > 275 MPa<br />

12.32 450 600 30 35 AW welded in steel<br />

with ReL > 355 MPa<br />

12.34 390 540 20 50 AW welded in Mo-alloyed steel with ReL<br />

> 275 MPa<br />

12.40 360 590 17 20 AW welded in steel<br />

with ReL > 275 MPa<br />

With the ES process, the mechanical values of the weld metal are highly dependent on procedure and base material.<br />

OK Flux 10.50 is a fused, highbasic<br />

flux for electro slag<br />

welding (vertically up). In this<br />

process, resistive heating of the<br />

liquid slag melts the wire.<br />

Depositions rates of 40 kg/h<br />

are easily achievable with<br />

multi-wire systems.<br />

The flux is suitable for single<br />

and multi-wire procedures, for<br />

DC and AC welding and is<br />

used for unlimited plate<br />

thicknesses.<br />

Once the welding process<br />

begins, the OK Flux 10.50<br />

suppresses the welding arc.<br />

Water-cooled copper bars that<br />

slide vertically-up parallel to the<br />

proceeding welding process<br />

support the molten weld pool.<br />

The mechanical values of the<br />

weld metal can be influenced<br />

by the choice of the wire<br />

electrode or welding procedure.<br />

Due to the high dilution the<br />

base material also has a major<br />

influence. Electro slag welding<br />

vertically-up can be applied to<br />

a wide range of steels such as<br />

structural steels, fine-grained<br />

steels and pressure vessel<br />

steels.<br />

For more information view the Product Data Sheets or contact ESAB.<br />