220 V Revelation by Draper Page 8 of 8 VIC12 Kit Installation Instructions The VIC 12 KIT includes all the components necessary for the VIC 12 to work with the Revelation. Follow these steps to install the components in this KIT. ➀ Close the door to the Revelation. FIGURE #1 ➁ DISCONNECT POWER TO THE REVELATION. ➂ ➃ ➄ Remove the covers from the electrical enclosure. Attach the pre-wired limit switch [1] to the shaft mounting bracket which is closest to the motor as shown in FIGURE #1. Using the #6–32 x 1" [2] long screws and #6 lock washers [2] provided. Run the wires through the open grommet in the end of the electrical enclosure that is toward the motor as shown in FIGURE #1 and connect them as fol lows: Connect the black wire to screw #1 of TB2 CR 1 CR 2 C 1 TB 2 12345678 910 Black Blue Motor Pre-wired limit switch 12V Actuator lever Connect the blue wire to screw #2 of TB2. (Be sure that wires do not interfere with moving linkage or the sliding inner pan) ➅ ➆ Put the 12V ACTIVATOR LEVER [3] onto the shaft as shown in Figure #2. The 12V ACTUATOR LEVER will need to be spread out before it will fit onto the shaft. The door to the Revelation must be closed before going on to step #7 Position the 12V ACTUATOR LEVER by rotating it into the limit switch until the limit switch clicks and secure the lever onto the shaft using the #10-32 screw [4] and lock washer [5] supplied with the lever. (Be sure that the screw on the lever is tightened so that the lever does not twist on the shaft.) FIGURE #2 12V actuator lever ➇ ➈ ➉ After the VIC 12 [7] is installed with the screen, run the wiring to the Revelation using the cord strain relief [6] and connect to TB1 as shown in the Rev e la tion wiring diagram. Put the covers back on to the electrical enclosure. Reconnect power to the revelation. Rotate lever until the limit switch clicks. Tighten lever onto shaft. Pre-wired limit switch VIC 12 OR VIC 12 MODIFIED INSTALLATION PART LIST ITEM # DESCRIPTION QTY 1 PRE-WIRED LIMIT SWITCH 1 2 SCREW #6–32 X 1"(25.4mm) LONG 2 PHIL PAN HD W/ EXT LOCK WASHER 3 12v ACTUATOR LEVER 1 4 SCREW #10–32 X 3/8" (9.525mm) LONG SHCS 1 5 WASHER #10–.190" I.D. X .375" (9.525mm) O.D. 1 ZINC INTERNAL TOOTH 6 FITTING CORD CRIMP STRAIN RELIEF 1 7 VIC 12 OR VIC 12 MODIFIED 1 TOOLS NEEDED MED POINT PHILLIP SCREW DRIVER I /8" FLAT BLADE SCREW DRIVER 3 /16" ALLEN WRENCH www.draperinc.com (765) 987-7999

220 V <strong>Revelation</strong> by <strong>Draper</strong> Page 8 of 8<br />

VIC12 Kit Installation <strong>Instructions</strong><br />

The VIC 12 KIT includes all the components necessary for the VIC 12 to work<br />

with the <strong>Revelation</strong>. Follow these steps to install the components in this KIT.<br />

➀ Close the door to the <strong>Revelation</strong>.<br />

FIGURE #1<br />

➁<br />

DISCONNECT POWER TO THE REVELATION.<br />

➂<br />

➃<br />

➄<br />

Remove the covers from the electrical enclosure.<br />

Attach the pre-wired limit switch [1] to the shaft mounting bracket which<br />

is closest to the motor as shown in FIGURE #1. Using the<br />

#6–32 x 1" [2] long screws and #6 lock washers [2] provided.<br />

Run the wires through the open grommet in the end of the electrical<br />

enclosure that is toward the motor as shown in FIGURE #1 and connect<br />

them as fol lows:<br />

Connect the black wire to screw #1 of TB2<br />

CR 1<br />

CR 2<br />

C 1<br />

TB 2<br />

12345678 910<br />

Black<br />

Blue<br />

Motor<br />

Pre-wired limit switch<br />

12V Actuator lever<br />

Connect the blue wire to screw #2 of TB2. (Be sure that wires do not<br />

interfere with moving linkage or the sliding inner pan)<br />

➅<br />

➆<br />

Put the 12V ACTIVATOR LEVER [3] onto the shaft as shown in Figure<br />

#2. The 12V ACTUATOR LEVER will need to be spread out before it will<br />

fit onto the shaft. The door to the <strong>Revelation</strong> must be closed before going<br />

on to step #7<br />

Position the 12V ACTUATOR LEVER by rotating it into the limit switch<br />

until the limit switch clicks and secure the lever onto the shaft using the<br />

#10-32 screw [4] and lock washer [5] supplied with the lever. (Be sure<br />

that the screw on the lever is tightened so that the lever does not twist on<br />

the shaft.)<br />

FIGURE #2<br />

12V actuator lever<br />

➇<br />

➈<br />

➉<br />

After the VIC 12 [7] is installed with the screen, run the wiring to the<br />

<strong>Revelation</strong> using the cord strain relief [6] and connect to TB1 as shown<br />

in the Rev e la tion wiring diagram.<br />

Put the covers back on to the electrical enclosure.<br />

Reconnect power to the revelation.<br />

Rotate lever<br />

until the limit<br />

switch clicks.<br />

Tighten lever<br />

onto shaft.<br />

Pre-wired<br />

limit switch<br />

VIC 12 OR VIC 12 MODIFIED INSTALLATION PART LIST<br />

ITEM # DESCRIPTION QTY<br />

1 PRE-WIRED LIMIT SWITCH 1<br />

2 SCREW #6–32 X 1"(25.4mm) LONG 2<br />

PHIL PAN HD W/ EXT LOCK WASHER<br />

3 12v ACTUATOR LEVER 1<br />

4 SCREW #10–32 X 3/8" (9.525mm) LONG SHCS 1<br />

5 WASHER #10–.190" I.D. X .375" (9.525mm) O.D. 1<br />

ZINC INTERNAL TOOTH<br />

6 FITTING CORD CRIMP STRAIN RELIEF 1<br />

7 VIC 12 OR VIC 12 MODIFIED 1<br />

TOOLS NEEDED<br />

MED POINT PHILLIP SCREW DRIVER<br />

I<br />

/8" FLAT BLADE SCREW DRIVER<br />

3<br />

/16" ALLEN WRENCH<br />

www.draperinc.com (765) 987-7999