SINGULUS MASTERING Internati<strong>on</strong>al GmbH<br />
Document number: 051006 AM Direct Annex<br />
9.4 DI water <strong>system</strong> requirements<br />
Electrical power<br />
DI Water System 230VAC, +6%, -10%<br />
50Hz/ 60Hz<br />
1-Phase<br />
Neutral<br />
Protective earth<br />
Fuse protecti<strong>on</strong>: 16A circuit breaker<br />
Power c<strong>on</strong>sumpti<strong>on</strong>: 0.25kVA<br />
Heat load to room: 0.25kW<br />
Feedwater<br />
DI Water System<br />
Water quality: Potable tap water<br />
C<strong>on</strong>ductivity: < 2000 µS/cm <str<strong>on</strong>g>for</str<strong>on</strong>g> max. Per<str<strong>on</strong>g>for</str<strong>on</strong>g>mance<br />
Temperature: 2 – 35 °C<br />
Fouling index: Progard 1: