23.07.2014 Views

measuring maximum subwoofer output according ansi/cea-2010 ...

measuring maximum subwoofer output according ansi/cea-2010 ...

measuring maximum subwoofer output according ansi/cea-2010 ...

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

MEASURING MAXIMUM SUBWOOFER OUTPUT ACCORDING CEA-<strong>2010</strong> (ANSI)<br />

f LOW (Hz) f HIGH (Hz) Limit (dB) Notes<br />

16 1.59 f 0 0 Fundamental<br />

1.59 f 0 2.52 f 0 -10 2 nd harmonic<br />

2.52 f 0 3.78 f 0 -15 3 rd harmonic<br />

3.78 f 0 5.61 f 0 -20 4 th , 5 th harmonic<br />

5.61 f 0 8.50 f 0 -30 6 th , 7 th , 8 th<br />

8.50 f 0 10 k -40 Hi order >9 th<br />

Figure 3: Limit curve for fundamental frequency of 100 Hz and table with<br />

ANSI/CEA-<strong>2010</strong> limits<br />

PERFORMING A CEA-<strong>2010</strong> BURST TEST WITH CLIO<br />

The CLIO 10.31 software release features a new generator stimulus and custom<br />

FFT options that, when used together, allow to perform a CEA-<strong>2010</strong> burst test in a<br />

very simple way.<br />

CLIO CEA-<strong>2010</strong> TONE BURST GENERATOR<br />

A powerful hann-burst tone option has been added to the Signal Generator. Selecting<br />

the CEA Burst option in the generator opens a dialog with the burst options (figure 4).<br />

The generator settings are: burst frequency f 0 in Hz, Number of Cycles and Repetition<br />

Time in ms. While the CEA-<strong>2010</strong> standard requests for a 6.5 cycles burst, we left<br />

the possibility to modify this parameter as it gives the opportunity to use different<br />

“burst-on” durations. For example it is possible to use a 7 cycles burst which is amplitude<br />

symmetrical, instead of 6.5 cycles which is not amplitude symmetrical, while<br />

4/12 www.audiomatica.com