22.07.2014 Views

EXCEL D and BASEX D - Soredex

EXCEL D and BASEX D - Soredex

EXCEL D and BASEX D - Soredex

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>EXCEL</strong> D <strong>and</strong> <strong>BASEX</strong> D


<strong>EXCEL</strong> D <strong>and</strong> <strong>BASEX</strong> D<br />

This year <strong>Soredex</strong> introduces a range of new<br />

features for the highly acclaimed CRANEX<br />

digital panoramic X-ray units. These new<br />

features make the units even easier to use<br />

<strong>and</strong> enhance the acquisition of diagnostic<br />

information - highly developed features that<br />

have been improved even more. The objective<br />

is to produce optimal usability <strong>and</strong> imaging<br />

results with less effort from the user.


<strong>EXCEL</strong> D, <strong>BASEX</strong> D<br />

MiniDose function<br />

The new MiniDose function ensures that patients receive<br />

the minimum x-ray dose, while the image quality remains<br />

first class. The technical factors are a constant 65 kV, 6 mA,<br />

<strong>and</strong> there are no adjustments on the control panel, because<br />

the CCD sensor is extremely sensitive <strong>and</strong> the advanced<br />

electronics <strong>and</strong> software guarantee the correct exposure. This<br />

makes using CRANEX digital units even easier than before.<br />

There is no need to select exposure values for<br />

different patients<br />

– the exposure dose is minimal for every patient <strong>and</strong> no<br />

retakes are normally needed. Just position the patient,<br />

press the exposure button <strong>and</strong> a perfectly exposed<br />

image will appear on the computer screen.<br />

The AE function<br />

The software of the digital CCD sensor automatically adjusts<br />

the image data distribution so that dense <strong>and</strong> soft tissue<br />

structures of the anatomy become more visible. This<br />

Automatic Equalization feature reduces the need for<br />

further image manipulations <strong>and</strong> adjustments; the original<br />

image that appears on the computer screen can normally be<br />

used directly as a basis for diagnosis. Time can be saved <strong>and</strong><br />

clinical efficiency <strong>and</strong> throughput times can be improved.<br />

0.4 focal spot<br />

A new tube is implemented in the Cranex Excel D model.<br />

A 0.4 focal spot increases the image quality even more.<br />

The smaller focal spot size increases the resolving power of the<br />

unit, so that even very small details become visible <strong>and</strong> more<br />

diagnostically critical information can be obtained from the<br />

image.<br />

All these new features really do increase the benefits to the users <strong>and</strong> patients.<br />

The cost-effectiveness of the enhanced CRANEX series is even better than before.<br />

More image information with less radiation.


<strong>EXCEL</strong> D <strong>and</strong> <strong>BASEX</strong> D<br />

MAIN DIMENSIONS<br />

150<br />

(6")<br />

1200 (47")<br />

850-1700 (33" - 67")<br />

2200 (88")<br />

2170 ±20 (86±1")<br />

406 (16")<br />

970 (38")<br />

Main Office:<br />

Nahkelantie 160, Tuusula<br />

P.O.Box 148, FI-04301 TUUSULA,<br />

Finl<strong>and</strong><br />

info@soredex.com<br />

SOREDEX, U.S.A.<br />

300 W. Edgerton Ave.<br />

Milwaukee, WI 53207 U.S.A.<br />

Tel: +1 800 235 8854<br />

Fax: +1 414 481 8665<br />

info@soredexusa.com<br />

SOREDEX, Germany<br />

Siemenstrasse 12, 77694 Kehl,<br />

Postfach 20 44,<br />

77680 Kehl, Deutschl<strong>and</strong><br />

Fax: 07851/ 93 29-30<br />

kontakt@soredex.de<br />

General<br />

Generator<br />

High frequency DC generator, operating frequency 40 kHz<br />

X-ray tube<br />

oPX 105 or equal<br />

Focal spot size<br />

0.4 mm IEC 336 in Cranex Excel D, 0.5 mm IEC 336 in <strong>BASEX</strong> D<br />

Minimum total filtration 2.5 mm Al<br />

Anode voltage<br />

65 kV<br />

Anode current<br />

6 mA<br />

Exposure time<br />

19/16 s (50/60 Hz) panoramic<br />

SID<br />

520 mm panoramic<br />

Line voltage<br />

230/240 Vac ±10% (50/60 HZ)<br />

Fusing<br />

8 A slow<br />

Weight<br />

150 kg (331 lbs)<br />

Colour rAL 7035 <strong>and</strong> 9003<br />

Electrical safety<br />

classification<br />

iEC 601-1 class 1/B (UL listed)<br />

Digital panoramic units<br />

CCD sensor<br />

PDC<br />

Active sensor surface<br />

147.5 x 6.1 mm<br />

Pixel size<br />

0.096 mm<br />

File size<br />

Approximately 4.2 MB per full panoramic image<br />

Application software DIGORA ® for Windows ® 2.1<br />

computer requirements (minimum)<br />

DIGORA® is a registered trademark of SOREDEX, PaloDEx<br />

Group Oy. Other product names / trademarks are property of<br />

their respective owners. CE marked, CE number 0537. Electric<br />

safety according to IEC 60601-1. Operations comply with<br />

ISO 13485:2003, ISO 9001:2000 <strong>and</strong> ISO 14001:1996.<br />

SOREDEX reserves the right to make changes in specification<br />

<strong>and</strong> features shown herein at any time without notice or<br />

obligation. Contact your SOREDEX Representative for the<br />

most current information.<br />

© 2006 SOREDEX<br />

03/06 72069<br />

Operating system<br />

CPU<br />

RAM<br />

HDD<br />

Video RAM<br />

Network<br />

Display<br />

Windows ® NT 4.0, 2000 or XP<br />

(Service Packs: NT 4/SP 4, 2000/SP 2, XP/SP 1)<br />

Pentium III<br />

256 MB<br />

20 GB<br />

16 MB of video memory<br />

10/100 Mbit/s, Base T x2<br />

or two (2) equivalent network interface cards<br />

19” CRT or 17” TFT-LCD,<br />

1280x1024 pixels, True Color<br />

CD-RW Drive<br />

www.soredex.com • www.soredex.de • www.soredexusa.com