MP2600iec Hardware Manual
MP2600iec Hardware Manual
MP2600iec Hardware Manual
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
4.4.2 Outputs<br />
4.4 Controller Digital I/O<br />
4.4.2 Outputs<br />
• 8 general purpose<br />
• Optically isolated<br />
• 24 V @ 50 mA<br />
• Current source or sink (connection to both emitter and collector are<br />
provided)<br />
• High speed digital output feature can set DO_07 within 13s of passing a<br />
specified encoder position. See Axis Parameters in the PLCopen Plus<br />
Function Block <strong>Manual</strong> to configure.<br />
Digital Output Circuit<br />
Connection Examples of Output Circuits<br />
• Relay Circuit Example<br />
SERVOPACK<br />
5 to 24 VDC<br />
Relay<br />
0V<br />
• Line Receiver Circuit Example<br />
SERVOPACK<br />
5 to 12 VDC<br />
17