80 Technical data – optional extras Optional upgrades for air conditioners 3.39 Generators TEC 29 TEC 29LPG TEC 30EV TEC 40D T 2500H Ref. No. 9102900200 9102900179 9102900033 9102900201 9102900005 Operating mode / fuel Normal ROZ 91 petrol Gas: LPG containing at least 60% of propane Diesel Diesel Normal ROZ 91 petrol Consumption max. 1.2 l/h max. 1.0 kg/h max. 0.7 l/h max. 1.4 l/h max. 1.2 l/h Continuous output (W) 2.600 2.600 2.500 3.500 2.000 Peak output (W) 2.900 2.900 2.900 3.900 2.200 Output voltage 230 volts AC ±1% (continuous) / pure sine wave 230 volts AC ±1% (continuous) / pure sine wave 230 volts AC ±1% (continuous) / pure sine wave 230 volts AC ±1% (continuous) / pure sine wave 230 volts AC ±1% (continuous) / pure sine wave Short circuit protection Max. starting current (A) 33 33 33 45 24 Sound level at 7 metres (dBA) 54 – 59 54 – 59 60 64 60 Soundproofed Operation via external control panel Test marks CE, E13 CE, E13 CE, E13 CE, E24 CE, E3 Engine output (kW (PS)) 4.0 (5.5) 4.0 (5.5) 3.3 (4.5) 4.7 (6.4) 4.0 (5.5) Width with suspension (mm) Size (W x H x D mm) 580 580 572 765 640 480 x 290 x 385 480 x 290 x 385 465 x 465 x 466 765 x 457 x 467 530 x 290 x 385 Housing finish Stainless steel Stainless steel Stainless steel Stainless steel Stainless steel Weight (kg) 44.0 44.0 70.0 96.5 50.0 Compatible with Dometic air conditioners FreshLight 1600 FreshLight 2200 FreshJet 1100 FreshJet 1700 FreshJet 2200 B 2200 more infos p. 111 more infos p. 111 more infos p. 111 more infos p. 111 B 2600 — B 3200 — HB 2500 — FreshWell 2000 more infos p. 111 Contents, specifications and availability are subject to change due to the technical improvement.
Technical data – optional extras 81 Standard solutions 2.08 Comfort solutions 2.08 DC kits for 12-volt operation DC-Kit-1 DC-Kit-2 DC-Kit-3 DC-Kit-4 Ref. No. 9100300003 9100300001 9100300002 9100300044 Power consumption 30 – 40 100 – 150 30 – 113 100 – 150 (12 Volt DC) (A)* 1 Recommended generator ≥ 75 ≥ 150 ≥ 150 ≥ 150 capacity (A)* 2 Recommended total battery ≥ 80 ≥ 250 ≥ 250 ≥ 250 capacity (Ah)* 3 Continuous output (watts) 1000 1600 1500 2000 Mobile climate solutions Size (W x H x D mm) Inverter Mains priority circuit 210 x 77 x 300 — 210 x 77 x 410 — 191 x 88 x 415 190 x 80 x 80 349 x 116 x 516 — Scope of delivery Inverter sine sine similar output voltage Mains priority circuit + 2 sockets Remote control, control cable (m) 2 battery cables, 1.5 m long (mm 2 ) 230-volt connection cable (piece) Charging current distributor with relay with power relay — — 5 16 1 — — — 5 25 1 — — 7.5 35 2 — — — 7.5 35 2 — Compatible with Dometic air conditioners FreshLight 1600 — — FreshLight 2200 — — FreshJet 1100 — — FreshJet 1700 — — FreshJet 2200 — — B 2200 — — B 2600 — — — B 3200 — — — HB 2500 — — — FreshWell 2000 — — — — * 1 Power consumption depends on the type of air conditioner and ambient temperatures. * 2 Generator capacity depends on the type of air conditioner and ambient temperatures. * 3 Total battery capacity depends on the type of air conditioner and ambient temperatures. Contents, specifications and availability are subject to change due to the technical improvement.
- Page 29 and 30: Technical data - portable coolers 2
- Page 31 and 32: Waeco tropicool 4.01 Thermo electri
- Page 33 and 34: all technical data, see p. 54 - 61
- Page 35 and 36: Simply swap! All technical data, se
- Page 37 and 38: All technical data, see p. 54 - 61
- Page 39 and 40: enefits ≥ Patented, easy-to-remov
- Page 41 and 42: enefits of the “big guys”: ≥
- Page 43 and 44: all technical data, see p. 54 - 61
- Page 45 and 46: all technical data, see p. 54 - 61
- Page 47 and 48: All technical data, see p. 54 - 61
- Page 49 and 50: All technical data, see p. 54 - 61
- Page 51 and 52: All technical data, see p. 54 - 61
- Page 53 and 54: all technical data, see p. 54 - 61
- Page 55 and 56: RMS 8500 / 8501 / 8505 RMS 8500 RMS
- Page 57 and 58: Technical data - refrigerators Dome
- Page 59 and 60: Technical data - refrigerators WAEC
- Page 61 and 62: accessories for coolers and compres
- Page 63 and 64: Mobile climate solutions 63 Mobile
- Page 65 and 66: Mobile climate solutions 65 Roof ai
- Page 67 and 68: for all technical data, see page 78
- Page 69 and 70: for all technical data, see page 78
- Page 71 and 72: For all technical data, see page 78
- Page 73 and 74: for all technical data, see page 79
- Page 75 and 76: for all technical data, see page 79
- Page 77 and 78: Optional extras - air conditioners
- Page 79: Technical data - air conditioners 7
- Page 83 and 84: Mobile energy systems 83 Mobile Ene
- Page 85 and 86: Mobile energy systems 85 battery co
- Page 87 and 88: Battery controller 87 exact battery
- Page 89 and 90: All technical data, see P. 96 - 97
- Page 91 and 92: All technical data, see P. 96 - 97
- Page 93 and 94: All technical data, see P. 96 - 97
- Page 95 and 96: All technical data, see P. 96 - 97
- Page 97 and 98: Technical data - Chargers / IU char
- Page 99 and 100: All technical data, see P. 112 - 11
- Page 101 and 102: VerSionS WitHoUt MAinS Priority Cir
- Page 103 and 104: All technical data, see P. 112 - 11
- Page 105 and 106: All technical data, see P. 114 - 11
- Page 107 and 108: All technical data, see P. 113 or w
- Page 109 and 110: Battery package 109 “JUiCe” for
- Page 111 and 112: All technical data, see P. 116- 117
- Page 113 and 114: Technical data - Inverters 113 Waec
- Page 115 and 116: Technical data - Inverters 115 Waec
- Page 117 and 118: Technical data - Generators 117 TEC
- Page 119 and 120: Mobile safety solutions 119 Mobile
- Page 121 and 122: all technical data, see p. 130 - 13
- Page 123 and 124: all technical data, see p. 130 - 13
- Page 125 and 126: all technical data, see p. 130 - 13
- Page 127 and 128: all technical data, see p. 130 - 13
- Page 129 and 130: all technical data, see p. 130 - 13
Technical data – optional extras<br />
81<br />
Standard solutions<br />
2.08 Comfort solutions<br />
2.08<br />
DC kits<br />
for 12-volt operation<br />
DC-Kit-1 DC-Kit-2 DC-Kit-3 DC-Kit-4<br />
Ref. No. 9100300003 9100300001 9100300002 9100300044<br />
Power consumption<br />
30 – 40 100 – 150 30 – 113 100 – 150<br />
(12 Volt DC) (A)* 1<br />
Recommended generator<br />
≥ 75 ≥ 150 ≥ 150 ≥ 150<br />
capacity (A)* 2<br />
Recommended total battery ≥ 80 ≥ 250 ≥ 250 ≥ 250<br />
capacity (Ah)* 3<br />
Continuous output (watts) 1000 1600 1500 2000<br />
Mobile climate solutions<br />
Size (W x H x D mm)<br />
Inverter<br />
Mains priority circuit<br />
210 x 77 x 300<br />
—<br />
210 x 77 x 410<br />
—<br />
191 x 88 x 415<br />
190 x 80 x 80<br />
349 x 116 x 516<br />
—<br />
Scope of delivery<br />
Inverter<br />
sine<br />
sine similar output voltage<br />
Mains priority circuit<br />
+ 2 sockets<br />
Remote control, control cable (m)<br />
2 battery cables, 1.5 m long (mm 2 )<br />
230-volt connection cable (piece)<br />
Charging current distributor<br />
with relay<br />
with power relay<br />
—<br />
—<br />
5<br />
16<br />
1<br />
—<br />
—<br />
—<br />
5<br />
25<br />
1<br />
—<br />
—<br />
7.5<br />
35<br />
2<br />
—<br />
—<br />
—<br />
7.5<br />
35<br />
2<br />
—<br />
Compatible with Dometic<br />
air conditioners<br />
FreshLight 1600 — —<br />
FreshLight 2200 — —<br />
FreshJet 1100 — —<br />
FreshJet 1700 — —<br />
FreshJet 2200 — —<br />
B 2200 — —<br />
B 2600 — — —<br />
B 3200 — — —<br />
HB 2500 — — —<br />
FreshWell 2000 — — — —<br />
* 1 Power consumption depends on the type of air conditioner and ambient temperatures.<br />
* 2 Generator capacity depends on the type of air conditioner and ambient temperatures.<br />
* 3 Total battery capacity depends on the type of air conditioner and ambient temperatures.<br />
Contents, specifications and availability are subject to change due to the technical improvement.