17.07.2014 Views

2 - AA Electric

2 - AA Electric

2 - AA Electric

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

electric<br />

IEC style contactors<br />

Spare parts<br />

3-29<br />

Coils for<br />

B115-B630<br />

contactors<br />

Bridge rectifier<br />

Coil protection<br />

Coil assembly<br />

For contactor Catalog number Price<br />

§ each<br />

Bridge rectifier (Faston terminals).<br />

B115-B145-B180 11 BA1575 1 81.00<br />

B250-B310-B400 11 BA1700 1 95.00<br />

B500-B630-B630 1000 11 BA1799 172.00<br />

B1250-B1600<br />

Coil protection.<br />

B115-B145-B180 11 BA1553 25.00<br />

B250-B310-B400 11 BA1678 45.00<br />

B500-B630-B630 1000 11 BA1803 97.00<br />

B1250-B1600<br />

Coil assembly (Coil, rectifier and coil protection).<br />

B115-B145-B180 11 BA1546 ❶ 234.00<br />

B250-B310-B400 11 BA1671 ❶ 378.00<br />

B500-B630-B630 1000 11 BA1796 ❷ 670.00<br />

B1250-B1600<br />

❶ Complete catalog number with coil digit per following table.<br />

Coil digit<br />

Voltage range<br />

AC/DC<br />

024 24V<br />

110 110/125V<br />

220 220/240V<br />

460 440/480V<br />

Other coil voltage values are available on request.<br />

❷ Complete catalog number with coil digit per following table.<br />

Coil digit<br />

Voltage range<br />

AC/DC<br />

110 110/125V<br />

220 220/240V<br />

460 440/480V<br />

Other coil voltage values are available on request.<br />

Operational characteristics<br />

AC and DC control<br />

For contactor type<br />

B115 - B145 - B180<br />

Supply voltage<br />

AC and DC<br />

Rated control voltage V 24-480<br />

Operating limits pick-up % Us 80-110<br />

drop-out % Us 30-60<br />

Consumption in-rush VA/W 300<br />

holding VA/W 10<br />

Dissipation W 10<br />

For contactor type<br />

B250 - B310 - B400<br />

Supply voltage<br />

AC and DC<br />

Rated control voltage V 24-480<br />

Operating limits pick-up % Us 80-110<br />

drop-out % Us 30-60<br />

Consumption in-rush VA/W 300<br />

holding VA/W 10<br />

Dissipation W 10<br />

For contactor type<br />

B500 - B630<br />

B630 1000<br />

Supply voltage<br />

AC and DC<br />

Rated control voltage V 48-480<br />

Operating limits pick-up % Us 80-110<br />

drop-out % Us 30-60<br />

Consumption in-rush VA/W 400<br />

holding VA/W 18<br />

Dissipation W 18<br />

3<br />

AC control<br />

For contactor type<br />

B1250 - B1600<br />

Supply voltage<br />

in AC<br />

Rated control voltage V 110-240-480<br />

Operating limits pick-up % Us 80-110<br />

drop-out % Us 30-60<br />

Consumption in-rush VA/W 800<br />

holding VA/W 45<br />

Dissipation W 40<br />

Operating limits for ambient temperatures up to<br />

105°F (40°C) are 0.8 to 1.1 times rated voltage.<br />

NOTE: For use at ambient temperatures exceeding 130°F<br />

(55°C), contact Sales & Technical Support.<br />

Materials<br />

Class F enamelled copper wire.<br />

Coil assembly<br />

Comprises the coil, bridge rectifier, fixed magnetic core, coil<br />

protection, cross piece and fixing screws.<br />

Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />

Web : www.A-Aelectric.com Email: njsales@a-aelectric.com

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!