2 - AA Electric
2 - AA Electric
2 - AA Electric
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
3-14<br />
IEC style contactors<br />
Add-on blocks and accessories for BF series contactors<br />
electric<br />
3<br />
Add-on blocks<br />
BFX10 (02-11-20)<br />
11 G484<br />
(03-12-21-30)<br />
BFX10<br />
(04-13-22-31-40)<br />
11 G418<br />
11 G481<br />
11 G482<br />
11 G485 - 11 G486<br />
11 G487<br />
11 G218<br />
11 G428 (01-01D-10-10A)<br />
Characteristics Maximum Catalog Price<br />
number per number<br />
contactor<br />
$ each<br />
Instantaneous auxiliary contacts with front center mounting.<br />
Screw terminals.<br />
2NC 1 BFX10 02 ❶ 14.00<br />
1NO + 1NC 1 BFX10 11 ❶ 14.00<br />
2NO 1 BFX10 20 ❶ 14.00<br />
4NC 1 BFX10 04 ❷ 28.00<br />
1NO + 3NC 1 BFX10 13 ❷ 28.00<br />
2NO + 2NC 1 BFX10 22 ❷ 28.00<br />
3NO + 1NC 1 BFX10 31 ❷ 28.00<br />
4NO 1 BFX10 40 ❷ 28.00<br />
3NC 1 11 G484 03 ❶ 22.00<br />
1NO + 2NC 1 11 G484 12 ❶ 22.00<br />
2NO + 1 NC 1 11 G484 21 ❶ 22.00<br />
3NO 1 11 G484 30 ❶ 22.00<br />
Instantaneous auxiliary contacts with front lateral mounting.<br />
Screw terminals.<br />
1NO 2 11 G418 10 13.20<br />
1EM early make 2 11 G418 10A 13.20<br />
1NC 2 11 G418 01 13.20<br />
1LB late break 2 11 G418 01D 13.20<br />
Faston terminals.<br />
1NO or 1NC reversible 2 11 G218 12.20<br />
2NO 2 11 G481 20 16.50<br />
1NO + 1NC 2 11 G481 11 16.50<br />
2NC 2 11 G481 02 16.50<br />
Double-throw❸ 2 11 G482❹ 30.80<br />
Side mount adapters.<br />
For G218 2 11 G280 3.50<br />
For G481 and G482 2 11 G483 4.60<br />
Auxiliary contacts for side mounting, duly fitted on side-mount<br />
adapter. Screw terminals.<br />
1NC 2 11 G428 01 17.40<br />
1LB late break 2 11 G428 01D 17.40<br />
1NO 2 11 G428 10 17.40<br />
1EM early make 2 11 G428 10E 17.40<br />
Delayed auxiliary contacts 1NO + 1NC (pneumatic operation)<br />
on energization ❶. Screw terminals.<br />
3 seconds 1 11 G485 3 112.00<br />
6 seconds 1 11 G485 6 112.00<br />
15 seconds 1 11 G485 15 112.00<br />
30 seconds 1 11 G485 30 112.00<br />
60 seconds 1 11 G485 60 112.00<br />
120 seconds 1 11 G485 120 112.00<br />
Delayed auxiliary contacts 1NO + 1NC (pneumatic operation)<br />
on de-energization ❶. Screw terminals.<br />
3 seconds 1 11 G486 3 112.00<br />
6 seconds 1 11 G486 6 112.00<br />
15 seconds 1 11 G486 15 112.00<br />
30 seconds 1 11 G486 30 112.00<br />
60 seconds 1 11 G486 60 112.00<br />
120 seconds 1 11 G486 120 112.00<br />
70 milliseconds 1 11 G487 112.00<br />
Operational characteristics for add-on auxiliary contacts<br />
Type G418 BFX10 G218 G482❻<br />
G428 G484 G481<br />
G485❺<br />
G486❺<br />
G487❺<br />
Rated current Ith A 10 10 10 0.1❼<br />
Rated insulation V 690 690 690 690<br />
voltage Ui<br />
Terminals: Screw M 3.5 M 3 –– ––<br />
Width mm 7 6.9 –– ––<br />
(0.2in) (0.2in)<br />
Faston mm –– –– 1-6.35 1-6.35<br />
2-2.8 2-2.8<br />
Conductor section<br />
maximum with 1<br />
or 2 wires<br />
flexible w/o lug mm 2 2.5 2.5 –– ––<br />
flexible c/w lug mm 2 2.5 2.5 2.5 2.5<br />
AWG n° 14 14 14 14<br />
Terminal protection IP20❽ IP20 IP20❿ IP20❿<br />
according to<br />
IEC/EN 60529<br />
UL AC A600 A600 A600 ––<br />
designation❹ DC P600❾ Q600 P600 ––<br />
Mechanical life cycles 10 11 10 10 10<br />
(in millions)<br />
❹ See page TC-25 for details.<br />
❺ For particularly severe ambient conditions, contact Sales & Technical<br />
Support.<br />
❻ Gold-plated contacts inside tight enclosure for use in pollutant<br />
environments.<br />
❼ Referred to 125VAC and 30VDC.<br />
❽ Finger safe IP20 protection is warranted to equipment wired with<br />
0.75mm 2 /18 AWG minimum conductor section for G418 or G428<br />
and 1mm 2 /18 AWG minimum for G480, G485, G486 and G487<br />
types.<br />
❾ Q600 for G418...<br />
❿ Finger safe IP20 protection is warranted to equipment wired with<br />
insulated Faston terminals.<br />
11 3 million cycles for G485, G486, G487.<br />
Positively guided contacts<br />
See page 3-21 or TC-21 for blocks with both NO and NC<br />
auxiliary contacts.<br />
SM1 manual starter - contactor connecting kits<br />
See page 1-5.<br />
Certifications and compliance<br />
BFX contacts: UL Listed for USA and Canada, file<br />
E93601; pending for BFX10 04, BFX10 13, BFX10 22,<br />
BFX10 31, BFX10 40.<br />
All others: UL Recognized for USA, file E93601 and CSA<br />
certified, file LR 54332-15.<br />
Compliant with standards: IEC/EN 60947-1,<br />
IEC/EN 60947-5-1.<br />
Maximum assembly combination of add-on blocks<br />
See page TC-28.<br />
❶ Highly conductive contacts. The contacts can<br />
also be fitted on B type contactors using the<br />
adapter G358. See pages 3-24 and 3-25.<br />
❷ Available during 2007; contact Sales & Technical<br />
Support for details.<br />
❸ Highly conductive contact.<br />
Dimensions<br />
page D-11 and 12<br />
Wiring diagrams<br />
pages W-3 and 4<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com<br />
Technical characteristics<br />
pages TC-4 to 29