17.07.2014 Views

2 - AA Electric

2 - AA Electric

2 - AA Electric

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

9-4<br />

Rotary cam switches<br />

GX series<br />

electric<br />

9<br />

U version<br />

front mounting.<br />

Motor switches<br />

U version<br />

front mounting.<br />

Voltmeter switches.<br />

Ammeter switches<br />

General Rated Front Catalog number Price<br />

purpose current plate<br />

AC21A size<br />

[A] [A] [mm] $ each<br />

MOTOR SWITCHES❶.<br />

Reversing switches. Three-pole – 3 wafers – scheme 11.<br />

12 16 ■ 48 GX16 11 U 49.00<br />

15 20 ■ 48 GX20 11 U 58.00<br />

32 32 ■ 65 GX32 11 U 79.00<br />

40 40 ■ 65 GX40 11 U 88.00<br />

Pole-changing switches. 4 wafers – scheme 13.<br />

12 16 ■ 48 GX16 13 U 70.00<br />

15 20 ■ 48 GX20 13 U 78.00<br />

32 32 ■ 65 GX32 13 U 110.00<br />

40 40 ■ 65 GX40 13 U 116.00<br />

Wye-delta switches. 2 wafers – scheme 12.<br />

12 16 ■ 48 GX16 12 U 70.00<br />

15 20 ■ 48 GX20 12 U 78.00<br />

32 32 ■ 65 GX32 12 U 110.00<br />

40 40 ■ 65 GX40 12 U 116.00<br />

3-pole motor reversing switches with spring return to 0.<br />

3 wafers – scheme 26.<br />

12 16 ■ 48 GX16 26 U 52.00<br />

15 20 ■ 48 GX20 26 U 59.00<br />

32 32 ■ 65 GX32 26 U 80.00<br />

❶ See side table for UL horsepower ratings.<br />

General Rated Front Catalog number Price<br />

purpose current plate<br />

AC21A size<br />

[A] [A] [mm] $ each<br />

VOLTMETER SWITCHES.<br />

Phase-Neutral L1-N/L2-N/L3-N – 2 wafers – scheme 68.<br />

12 16 ■ 48 0<br />

L1N GX16 68 U 51.00<br />

L2N<br />

L3N<br />

0 2<br />

1<br />

0 2<br />

1<br />

0 2<br />

1<br />

0 2<br />

1<br />

General characteristics<br />

- 16 to 40A capacity for motor switches<br />

- 16A capacity for voltmeter and ammeter switches<br />

- Extended mechanical and electrical life<br />

- Switching angles: 30°, 45°, 60° and 90°<br />

- Silver-alloy dual-breaking contacts. Direct<br />

(positive-guided) opening operation ; safety<br />

function per IEC/EN 60947-5-1<br />

- IP65 front degree of protection; IP20 contact degree<br />

of protection<br />

- Legend marking is standard supplied as illustrated in<br />

the catalog number table; any other on request.<br />

Selection guide<br />

See pages TC-34 and 35.<br />

Optional<br />

Enlarged front plate for GX16-GX20 (65x65mm instead<br />

of standard 48x48): Add “H” after the switch rating in<br />

the catalog number E.g. GX16H 11 U.<br />

Enlarged front plate for GX32-GX40 (90x90mm instead<br />

of standard 65x65): Add “H” after the switch rating in<br />

the catalog number E.g. GX32H 11 U.<br />

Special versions<br />

In addition to standard types, particular versions are<br />

available with special operating circuit schemes.<br />

Contact Sales & Technical Support or complete the form;<br />

refer to the page just after TC-48.<br />

UL horsepower ratings<br />

Max AC23A<br />

Type 1 phase 3 phase power<br />

at 440V<br />

120V 240V 120V 240V 480V 600V [kW]<br />

GX16 3 /4 1 1 1 /2 3 5 5 6.5<br />

GX20 3 /4 1 1 /2 1 1 /2 3 5 5 7.5<br />

GX32 1 1 /2 3 3 7 1 /2 15 15 15<br />

GX40 2 5 5 10 15 15 18.5<br />

Example of U version switch mounting<br />

Phase-Phase L1-L2/L2-L3/L3-L1 – 2 wafers – scheme 67.<br />

12 16 ■ 48 0<br />

L1-L2 GX16 67 U 51.00<br />

L2-L3<br />

L3-L1<br />

For 3 phase to phase voltage and 3 phase voltage readings<br />

3 wafers – scheme 66.<br />

12 16 ■ 48 L1-L2<br />

0<br />

L1-N GX16 66 U 78.00<br />

L2-L3<br />

L3-L1<br />

L2-N<br />

L3-N<br />

For 1 phase voltage and 3 phase to phase voltage readings<br />

3 wafers – scheme 60.<br />

12 16 ■ 48 0<br />

L1N L1-L2 GX16 60 U 78.00<br />

L2-L3<br />

L3-L1<br />

Certifications and compliance<br />

UL listed for USA and Canada, File E155982.<br />

Compliant to standards: IEC/EN 60947-1,<br />

IEC/EN 60947-3, IEC/EN 60204-1, IEC/EN 61058-1.<br />

AMMETER SWITCHES.<br />

Direct L1-L2-L3 current readings – 5 wafers – scheme 97.<br />

12 16 ■ 48 0 GX16 97 U 80.00<br />

L3<br />

L1<br />

L2<br />

For L1-L2-L3 readings via 3 CTs – 3 wafers – scheme 98.<br />

12 16 ■ 48 0 GX16 98 U 62.00<br />

L3<br />

L1<br />

L2<br />

Front plate sizes<br />

48x48mm = 1.9x1.9in<br />

65x65mm = 2.6x2.6in<br />

90x90mm = 3.5x3.5in<br />

Accessories<br />

page 9-16<br />

Dimensions<br />

page D-27<br />

Wiring diagrams<br />

pages W-7 and 8<br />

Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />

Web : www.A-Aelectric.com Email: njsales@a-aelectric.com<br />

Technical characteristics<br />

pages TC-34 and 35