General catalog<br />
2007-2008<br />
Control solutions<br />
for industry<br />
PC01 US/CD 09 06<br />
2007-2008 USA CAN<br />
®<br />
electric<br />
100% electricity<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com
In the U.S.A.<br />
In Canada<br />
Sales & Technical Support<br />
Tel (757) 545-4700 Tel (450) 681-9200<br />
Fax (757) 545-2900 Fax (450) 681-9884<br />
E-mail info@LovatoUsa.com<br />
E-mail info@Lovato.ca<br />
at the customer’s<br />
service<br />
On line information<br />
www.LovatoUsa.com<br />
www.Lovato.ca<br />
Business Address<br />
LOVATO <strong>Electric</strong> Inc.<br />
LOVATO <strong>Electric</strong> Corp.<br />
124 Robert Hall Court 109 3200 Avenue Jacques Bureau<br />
CHESAPEAKE, VA 23324<br />
LAVAL, QC H7P 0A9<br />
USA<br />
Canada<br />
This catalog is for information purposes<br />
only and is subject to change without<br />
notice. Catalog descriptions, technical and<br />
operational data as well as other details<br />
herein specified do not have any contractual<br />
value so must be considered only as<br />
indication. The products, illustrated in this<br />
publication, are also subject to change or<br />
improvement at any moment and without<br />
prior notice so LOVATO ELECTRIC assume<br />
no responsibility for the effects of such<br />
changes. The products, given in this catalog,<br />
should be installed and used by qualified<br />
personnel and in compliance with the<br />
regulations in force for electric systems in<br />
order to avoid damages and safety hazards.<br />
The products, described in this catalog,<br />
do have a variety of uses; those<br />
responsible for the application and use of<br />
this control equipment must satisfy themselves<br />
that all necessary actions have been<br />
taken to ensure that each application and<br />
use meet all performance and safety<br />
requirements, including any applicable<br />
laws, regulations, codes and standards.<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com
WI THDRAW<br />
A01LOW BATERY VOLTAG<br />
A02HI BATERY VOLTAG GH<br />
A03LINE 1SWI TCH FAUL<br />
AT<br />
O<br />
OF<br />
TRI<br />
O<br />
LINE<br />
AUTOMATICTRANSFER SWI TCH CONTROLE<br />
A04LINE 2SWI TCH FAUL<br />
A05LINE PHASE SEQ 1WRONG<br />
A06LINE 2WRONG PHASE SEQ<br />
LOA<br />
LINE<br />
A07LOADNOT T.OU POWERED<br />
A08GENERATOR READ NOT<br />
A09EMERGENCY STO<br />
O<br />
WI THDRAW<br />
TRI<br />
O<br />
OF<br />
ALAR<br />
TES<br />
TES<br />
AU<br />
MA<br />
OF<br />
RESE<br />
Planet<br />
1 – Manual motor starters and protectors<br />
SWITCH<br />
2–Disconnect switches<br />
3–IEC style contactors<br />
4–Definite purpose contactors<br />
5–IEC style overload relays<br />
6–IEC style starters<br />
7–Push buttons and pilot devices, 22mm<br />
8–Limit, micro and foot switches<br />
9–Rotary cam switches<br />
our<br />
products<br />
Planet<br />
10 – Timers<br />
LOGIC DIN<br />
Planet<br />
L L L H<br />
L L L H<br />
11 – Protection relays<br />
12 – Liquid level control relays<br />
13 – Digital metering instruments and current transformers<br />
14 – Soft starters<br />
15 – Automatic power factor controllers<br />
16 – Automatic transfer switch controllers<br />
17 – Programmable logic relays<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com
newest<br />
products<br />
Motor starting and power control<br />
• Manual motor starters and protectors Page 1-2<br />
• IEC style contactors Page 3-2<br />
• IEC style overload relays Page 4-2<br />
• IEC style starters Page 5-2<br />
Digital measuring instruments<br />
• Modular Pages 13-2 and 13-3<br />
• Flush-mount Pages 13-4 and 13-5<br />
Add-on block with<br />
4 contacts for BF<br />
contactors<br />
Page 3-18<br />
12VAC/DC<br />
LED-integrated<br />
pilot lights<br />
Page 7-16<br />
Maintained illuminated<br />
mushroom-head<br />
operator plastic series<br />
Page 7-14<br />
Bi-directional<br />
limit switch<br />
Pages 8-6 8-7<br />
8-8 8-11<br />
Phase sequence<br />
and loss relay<br />
Page 11-2<br />
Liquid level<br />
control relay<br />
Page 11-2<br />
Start-up priority<br />
change relay<br />
Page 12-5<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com
Limit and micro switches<br />
• Prewired limit switches Page 8-18<br />
• Micro switches Page 8-26<br />
newest<br />
products<br />
Programmable logic relays<br />
• Master modules with 10, 12 or 10<br />
Inputs/Outputs, 24VDC-24VAC-110/240VAC Page 17-2<br />
• Expansion and communications modules Page 17-2<br />
Modular protection relays<br />
• Voltage monitoring at 600V Page 11-2<br />
• Current monitoring Page 11-4<br />
• Phase shift relays Page 11-5<br />
Soft starters<br />
up to 40HP at 600V<br />
Page 14-2<br />
Automatic transfer<br />
switch controllers<br />
Page 16-2<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com
COMPANY<br />
About us<br />
How to reach<br />
Quality<br />
PRODUCTS<br />
Our products<br />
News<br />
OnLine news<br />
FAQ<br />
INFORMATION<br />
Library-Download<br />
Fairs-Events<br />
Sales Organisation<br />
Contact us<br />
our internet<br />
site<br />
Our products<br />
The entire range of LOVATO<br />
<strong>Electric</strong> products with<br />
photographs, part numbers,<br />
characteristics and technical<br />
descriptions.<br />
News<br />
Up to date information and data<br />
of new products.<br />
Library-Download<br />
All available pubblications for our<br />
products.<br />
Software up-grades for our electronic<br />
products.<br />
Catalogs, brochures, technical<br />
instructions and data, software<br />
downloads, advertizing, etc., are<br />
available in English, Italian, Czech,<br />
French, Spanish, German, Polish,<br />
Portuguese and Russian.<br />
Fairs-Events<br />
The presence of LOVATO <strong>Electric</strong> at<br />
the main fair exhibitions during the<br />
current year, with handy links and<br />
indications.<br />
Calendars of LOVATO <strong>Electric</strong><br />
initiatives: Meetings, training courses<br />
for entire production or dedicated<br />
sectors.<br />
Sponsorships and sports events.<br />
www.Lovato.ca (for Canada)<br />
www.LovatoUsa.com (for USA)<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com
LOVATO <strong>Electric</strong>, solid tradition with 85 years<br />
of on-going activity, is leader in<br />
electromechanical and automation product<br />
manufacturing field for industry.<br />
Equipment of early<br />
LOVATO <strong>Electric</strong><br />
production.<br />
The presence of Lovato <strong>Electric</strong> in the most<br />
important world markets is the result of the<br />
company’s constant international strategy.<br />
Lovato <strong>Electric</strong> Italy, together with the ten<br />
foreign branches and official sales affiliates,<br />
represent the reference point for the<br />
distribution of the Lovato <strong>Electric</strong> products<br />
in over 80 countries.<br />
tradition and<br />
innovation<br />
LOVATO <strong>Electric</strong> in the world:<br />
LOVATO ELECTRIC S.P.A. (Italy)<br />
LOVATO ELECTRIC INC. (USA)<br />
LOVATO ELECTRIC CORP. (Canada)<br />
LOVATO ASIA (LTD (Hong Kong - China)<br />
LOVATO (U.K.) LTD (England)<br />
LOVATO DELTEC GMBH (Germany)<br />
LOVATO ELECTRIC SL (Spain)<br />
LOVATO ELECTRIC SP. Z O.O. (Poland)<br />
LOVATO SRO (Czech Republic)<br />
LOVATO REZ LTD (Latvia)<br />
LOVATO ELECTRIC DE MEXICO SA (Mexico)<br />
Modern technology for research,<br />
development, design and manufacture<br />
consent LOVATO <strong>Electric</strong> to offer products<br />
and solutions to enhance efficiency,<br />
reliability and safety in industrial and<br />
electrical systems.<br />
Manual motor starters, contactors, push<br />
buttons and selectors, digital multimeters,<br />
soft starters, automatic power factor<br />
controllers are just a few of the products<br />
entirely designed, developed and made by<br />
LOVATO <strong>Electric</strong>.<br />
Our products comply with major<br />
international standard requirements.<br />
LOVATO <strong>Electric</strong>, among the first in Italy, in<br />
1992, to hold the certification of the<br />
company’s quality management system, in<br />
compliance with ISO 9001 standards, has<br />
obtained the ISO 14001 certification for the<br />
environment management system as well.<br />
The company’s laboratories are, in addition,<br />
qualified and certified to conduct type<br />
testing, under ACAE direct control, for the<br />
emission of ACAE/LOVAG certifications.<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com
solutions and products<br />
Contactors for<br />
power factor<br />
correction<br />
Automatic<br />
power factor<br />
controllers<br />
Programmable logic<br />
relays<br />
Automatic transfer<br />
switch controllers<br />
Manual<br />
motor<br />
starters<br />
Disconnect<br />
switches<br />
Manual<br />
motor<br />
starters<br />
Timers<br />
Push buttons<br />
and selectors<br />
Contactors<br />
Contactors<br />
Voltage<br />
and<br />
current<br />
relays<br />
Contactors<br />
Overload<br />
relays<br />
Limit switches<br />
Micro<br />
switches<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com
for industrial automation<br />
Digital<br />
multimeters<br />
Digital<br />
multimeters<br />
Current<br />
transformers<br />
3-phase combined<br />
voltmeter, ammeter and<br />
wattmeter<br />
Disconnect<br />
switches<br />
IEC<br />
starters<br />
Soft sarters<br />
Rotary cam<br />
switches<br />
Limit switches<br />
IEC starters<br />
Liquid level<br />
control relays<br />
Foot switches<br />
Limit switches<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com
PAGE 1-2<br />
SM1B<br />
• Thermal trip adjustment ranges 0.1-32A<br />
(15 choices).<br />
PAGE 1-3<br />
SM2A<br />
• Thermal trip adjustment ranges 22-50A<br />
(4 choices).<br />
PAGE 1-3<br />
SM3A<br />
• Thermal trip adjustment ranges 45-100A<br />
(4 choices).<br />
PAGE 1-10<br />
LMS25<br />
• Thermal trip adjustment ranges 0.1-25A<br />
(13 choices)<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com
1<br />
MANUAL MOTOR STARTERS AND PROTECTORS<br />
Complete range from 0.1 to<br />
100 Amps<br />
Control and protection for<br />
individual or group motor<br />
applications<br />
Adjustable, single phase sensitive<br />
internal overload thermal trip<br />
class 10<br />
Short circuit protection<br />
Single lever circuit breaker type<br />
handle for SM types<br />
Terminals are IP20 touch-safe<br />
design<br />
Separate trip indicator/reset and<br />
test button<br />
Extensive assortment of<br />
accessories available<br />
RoHS compliant products available<br />
PLANET -SWITCH<br />
With thermal and magnetic trip releases<br />
SEC. PAGE<br />
Manual starters SM1B . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1- 2<br />
Manual starters SM2A and SM3A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1- 3<br />
Add-on blocks and accessories for SM1B . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1- 4<br />
Add-on blocks and accessories for SM2A and SM3A . . . . . . . . . . . . . . . . . . . . . . . . 1- 8<br />
Manual starters LMS25 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1- 10<br />
Add-on blocks and accessories for LMS25... . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1- 11<br />
Short-circuit tripping indicator, standard supplied<br />
on all SM1B starters.<br />
Reset the indicator, as illustrated, to restore the<br />
manual starter.<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com
Lovato<br />
L<br />
TEST<br />
1-2<br />
Manual motor starters and protectors<br />
electric<br />
1<br />
Manual motor<br />
starters SM1B<br />
up to 32A<br />
11 SM1B<br />
L<br />
Lovato<br />
TEST<br />
Setting range UL maximum horsepower ratings Catalog number Price<br />
of thermal trip ❶ Single-phase ❷ Three-phase<br />
120V 240V 200V 240V 480V 600V<br />
[A] [HP] [HP] [HP] [HP] [HP] [HP] $ each<br />
0.1-0.16 – – – – – – 11 SM1B 00 95.00<br />
0.16-0.25 – – – – – – 11 SM1B 04 95.00<br />
0.25-0.4 – – – – – – 11 SM1B 08 95.00<br />
0.4-0.63 – – – – – – 11 SM1B 12 100.00<br />
0.63-1 – – – – 1<br />
/2<br />
1<br />
/2 11 SM1B 16 100.00<br />
1-1.6 – 1<br />
/10 – – 3<br />
/4 1 11 SM1B 20 100.00<br />
1.6-2.5 – 1<br />
/6 – 1<br />
/2 1 1 1 /2 11 SM1B 24 100.00<br />
2.5-4 1<br />
/8<br />
1<br />
/3<br />
1<br />
/2<br />
3<br />
/4 2 3 11 SM1B 28 100.00<br />
4-6.5 1<br />
/4<br />
1<br />
/2<br />
3<br />
/4 1 1 /2 3 5 11 SM1B 32 100.00<br />
6.3-10 1<br />
/2 1 1 /2 1 1 /2 3 5 7 1 /2 11 SM1B 36 118.00<br />
9-14 3<br />
/4 2 2 3 10 10 11 SM1B 40 118.00<br />
13-18 1 3 5 5 10 15 11 SM1B 44 122.00<br />
17-23 1 1 /2 3 5 7 1 /2 15 20 11 SM1B 48 129.00<br />
20-25 2 3 7 1 /2 7 1 /2 15 20 11 SM1B 52 147.00<br />
24-32 2 5 10 10 20 30 11 SM1B 56 195.00<br />
❶ The appropriate thermal trip range of the manual starter should be selected on<br />
the basis of the motor nameplate full-load current since the horsepower<br />
General characteristics<br />
ratings given in the table are for reference only.<br />
❷ Single-phase horsepower ratings are based on wiring the three poles in series; The SM1B series is a new generation of manual starters<br />
see wiring scheme on page W-2..<br />
with thermal and magnetic trip releases. Motor control<br />
and protection, up to 20HP at 460V, are possible by the<br />
choice of suitable adjustment range, 0.1 to 32A.<br />
A magnetic trip indicator integrated on the SM1B<br />
starters avoids dangerous closing operations during<br />
short-circuit conditions, previously disconnected by the<br />
starter.<br />
The SM1B types are suitable for isolation.<br />
Operational characteristics<br />
– Rated insulation voltage Ui: 690V<br />
– Rated impulse voltage: 6kV<br />
– Rated frequency: 50/60Hz<br />
– Maximum rated current: 32A<br />
– Number of adjustment ranges: 15 (0.1 to 32A)<br />
– Power dissipation per phase: 2.2-9.7W<br />
– Magnetic tripping: 12 In max<br />
– Thermal tripping time class: 10A<br />
– Single-phase sensitive<br />
– Mechanical life: 100,000 cycles<br />
– <strong>Electric</strong>al life 32A (AC3): 100,000 cycles<br />
– Utilization category: A<br />
– Mounting on 35mm DIN rail (IEC/EN 60715)<br />
– Mounting position: any<br />
– Degree of protection: IP20.<br />
Certifications and compliance<br />
UL listed, for USA and Canada, file E93602.<br />
Compliant with standards: IEC/EN 60947-1,<br />
IEC/EN 60947-2, IEC/EN 60947-4-1.<br />
2.3Nm or<br />
20in lb max<br />
1Nm or<br />
9in lb max<br />
1Nm or<br />
9in lb max<br />
NOTE: When more than one starter are mounted, side by side, without<br />
leaving space between each to consent free air circulation on the<br />
starter sides, and have simultaneous operation, the thermal trip<br />
adjuster must be positioned at a value 15% higher than the rated<br />
motor current.<br />
Add-on blocks/Accessories<br />
pages 1-4 to 7<br />
Dimensions<br />
page D-2<br />
Wiring diagrams<br />
page W-2<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com<br />
Technical characteristics<br />
page TC-2
electric<br />
Manual motor starters and protectors<br />
1-3<br />
Manual motor<br />
starters SM2A-SM3A<br />
up to 100A<br />
11 SM2A<br />
11 SM3A<br />
Setting range UL maximum horsepower ratings Maximum short Catalog number Price<br />
of thermal trip ❶ Three-phase ciruit current<br />
rating<br />
200V 240V 480V 600V 480V 600V<br />
[A] [HP] [HP] [HP] [HP] [kA] [kA] $ each<br />
22-32 10 10 25 30 50 10 11 SM2A 64 340.00<br />
28-40 10 15 30 40 50 10 11 SM2A 68 365.00<br />
36-45 15 15 30 40 50 10 11 SM2A 72 429.00<br />
40-50 15 20 40 50 50 10 11 SM2A 76 429.00<br />
45-63 20 25 50 60 50 10 11 SM3A 84 454.00<br />
57-75 25 30 60 75 50 10 11 SM3A 88 518.00<br />
70-90 30 30 75 100 50 10 11 SM3A 92 544.00<br />
80-100 30 40 75 100 50 10 11 SM3A 96 608.00<br />
❶ The appropriate thermal trip range of the manual starter should be selected on<br />
the basis of the motor nameplate full-load current since the horsepower<br />
General characteristics<br />
ratings given in the table are for reference only.<br />
NOTE: These types can be used as components in Group Installation as per NEC The SM2 and SM3 types are manual motor starters with<br />
430.53 (C). This means that multiple manual starters can be installed a wide adjustment range, 22 to 100A, in only two frame<br />
below one circuit breaker, with each manual starter controlling and<br />
protecting its own motor.<br />
sizes enabling motor control and protection up to 60HP<br />
at 460V.<br />
A magnetic trip indicator and padlockable operating<br />
handle are integrated on the SM2 and SM3 starters.<br />
Both are suitable for isolation.<br />
Their high breaking capacity consents to exclude<br />
protection fuses on the majority of the installations.<br />
Operational characteristics<br />
– Rated insulation voltage Ui: 690V<br />
– Rated impulse voltage: 6kV<br />
– Rated frequency: 50/60Hz<br />
– Maximum rated current: 50A (SM2A) and<br />
100A (SM3A)<br />
– Number od adjustment ranges:<br />
SM2A: 4 (22 to 50A)<br />
SM3A: 4 (45 to 100A)<br />
– Power dissipation per phase<br />
SM2A: 7.1-20W<br />
SM3A: 10-38W<br />
– Magnetic tripping: 13 In max<br />
– Thermal tripping time class: 10<br />
– Single-phase sensitive<br />
– Life (cycles): Mechanical <strong>Electric</strong>al (Ie AC3)<br />
SM2A 50,000 25,000<br />
SM3A 50,000 25,000<br />
– Utilization category: A<br />
– Mounting:<br />
SM2A - screw fixing or on 35mm DIN rail<br />
(IEC/EN 60715)<br />
SM3A - screw fixing or on DIN rail 35mm<br />
(IEC/EN 60715) or 75mm (IEC/EN 60715)<br />
– Mounting position: Any<br />
– Degree of protection: IP00.<br />
Certifications and compliance<br />
UL listed, for USA and Canada, file E155982;<br />
CSA certified, file LR 73212.<br />
Compliant with standards: IEC/EN 60947-1,<br />
IEC/EN 60947-2, IEC/EN 60947-4-1.<br />
1<br />
NOTE: When more than one starter are mounted, side by side, without<br />
leaving space between each to consent free air circulation on the<br />
starter sides, and have simultaneous operation, the thermal trip<br />
adjuster must be positioned at a value 15% higher than the rated<br />
motor current.<br />
Add-on blocks/Accessories<br />
page 1-8 and 9<br />
Dimensions<br />
page D-3<br />
Wiring diagrams<br />
page W-2<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com<br />
Technical characteristics<br />
pages TC-2 and 3
1-4<br />
Manual motor starters and protectors<br />
Add-on blocks and accessories for SM1B types<br />
electric<br />
1<br />
11 SMX11... 11 SMX12...<br />
11 SMX13 11<br />
11 SMX15 11 SMX16<br />
11 SMX18 10<br />
11 SMX90 3<br />
11 SMX90 4<br />
11 SMX14<br />
11 SMX90 50 11 SMX90 31<br />
Characteristics Catalog Price<br />
number<br />
$ each<br />
Add-on auxiliary contacts.<br />
Front mount 2NO 11 SMX11 20 23.00<br />
Front mount 1NO+1NC 11 SMX11 11 23.00<br />
Side mount 1NO+1NC 11 SMX12 11 23.00<br />
Side mount 2NO 11 SMX12 20 23.00<br />
Side mount 2NC 11 SMX12 02 23.00<br />
Side mount indicator contacts 11 SMX13 11 34.00<br />
1NO+1NC for thermal and<br />
magnetic tripping ❶<br />
Undervoltage trip releases.<br />
110-127VAC 50/60Hz 11 SMX14 BC 57.00<br />
220-240VAC 50/60Hz 11 SMX14 CL 57.00<br />
380-400VAC 50/60Hz 11 SMX14 EA 57.00<br />
220-240VAC 50/60Hz 11 SMX15 CL 72.00<br />
with early-make contacts<br />
380-400VAC 50/60Hz 11 SMX15 EA 72.00<br />
with early-make contacts<br />
Shunt trip releases.<br />
24VAC 50/60Hz 11 SMX16 AF 57.00<br />
110-127VAC 50/60Hz 11 SMX16 BC 57.00<br />
220-240VAC 50/60Hz 11 SMX16 CL 57.00<br />
400-480VAC 50/60Hz 11 SMX16 EA 57.00<br />
Padlockable attachment for operating lever.<br />
3 padlocks max 11 SMX18 10 10.00<br />
Adjuster anti-tamper.<br />
For all types 11 SMX18 12 8.00<br />
Padlockable door interlock rotary operators.<br />
3 padlocks max.Red-yellow color 11 SMX18 14 95.00<br />
3 padlocks max. Black color 11 SMX18 15 95.00<br />
Terminal block for busbar supply.<br />
For all types 11 SMX90 50 21.00<br />
Three-phase connection busbars 13/4in (45mm) spacing.<br />
For 2 breakers without 11 SMX90 32 18.00<br />
side-mount contacts<br />
For 3 breakers without 11 SMX90 33 21.00<br />
side-mount contacts<br />
For 4 breakers without 11 SMX90 34 24.00<br />
side-mount contacts<br />
For 5 breakers without 11 SMX90 35 30.00<br />
side-mount contacts<br />
Safety cover.<br />
For unused busbar terminals 11 SMX 90 31 4.00<br />
Three-phase connection busbars 21/8in (54mm) spacing.<br />
For 2 breakers complete with 11 SMX90 42 18.00<br />
side-mount contacts<br />
For 3 breakers complete with 11 SMX90 43 21.00<br />
side-mount contacts<br />
For 4 breakers complete with 11 SMX90 44 24.00<br />
side-mount contacts<br />
For 5 breakers complete with 11 SMX90 45 30.00<br />
side-mount contacts<br />
Screw fixing adapter.<br />
Universal base for starter screw BFX89 01 3.00<br />
fixing<br />
❶ Tripping is viewed by the flag indicator on front.<br />
General and operational characteristics<br />
ADD-ON AUXILIARY BLOCKS<br />
– Snap on to the front or the right side of the starter<br />
– Maximum combination: 6 auxiliary contacts of which<br />
2 on front and 4 on the side (2 normal contacts and<br />
2 indicators)<br />
– Rated thermal current Ith: 6A (2.5A for SMX11...)<br />
– Rated insulation voltage Ui: 690V (250V for SMX11...)<br />
– UL designation: C600 Q600 (C300 R300 for SMX11...);<br />
see details on page TC-3.<br />
– Conductor cross section connectable (1 or 2 wires)<br />
min/max: 0.75/2.5 mm 2 or AWG 18/14.<br />
UNDERVOLTAGE TRIP RELEASE<br />
– Connectable to the left side of the starter<br />
– Consumption in-rush/holding: 12/3.5VA<br />
– Drop-out voltage: 0.35-0.7 Us<br />
– Pick-up voltage: 0.85-1.1 Us<br />
– Conductor cross section connectable (1 or 2 wires)<br />
min/max: 0.75/2.5mm 2 or AWG 18/14.<br />
SHUNT TRIP RELEASE<br />
– Connectable to the left side of the starter<br />
– Inrush consumption: 20VA<br />
– Operating voltage: 0.7-1.1 Us<br />
– Conductor cross section connectable (1 or 2 wires)<br />
min/max: 0.75/2.5mm 2 or AWG 18/14.<br />
THREE-PHASE CONNECTION BUSBAR<br />
– Imax 63A<br />
– SMX90 3... 45mm spacing to reduce the width to the<br />
minimum<br />
– SMX90 4... 54mm spacing to consent to fit one<br />
side-mount auxiliary contact block on the starter<br />
– Conductor cross section connectable to terminal<br />
block for busbar supply min/max: 4/25mm 2 or<br />
AWG 10/4.<br />
TERMINAL BLOCK FOR BUSBAR SUPPLY<br />
– Imax 63A<br />
– Conductor cross section connectable min/max:<br />
4/25mm 2 or AWG 10/4.<br />
Certifications and compliance<br />
UL listed, for USA and Canada, file E93602 (contacts,<br />
releases and padlockable attachment).<br />
Compliant with standards: IEC/EN 60947-1,<br />
IEC/EN 60947-5-1.<br />
BFX89 01<br />
Dimensions<br />
page D-2<br />
Wiring diagrams<br />
page W-2<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com<br />
Technical characteristics<br />
pages TC-2 and 3
electric<br />
Manual motor starters and protectors<br />
Add-on blocks and accessories for SM1B types<br />
1-5<br />
11 SMX90 03<br />
11 SMX17 10<br />
11 SMX17 11<br />
11 SMX31 41<br />
11 SMX32 41<br />
11 SMX90 10 11 SMX90 12<br />
11 SMX90 14<br />
11 SMX17 20<br />
Characteristics Catalog Price<br />
number<br />
$ each<br />
Rigid starter contactor connections.<br />
For SM1B starter with BG 11 SMX90 03 11.00<br />
mini-contactor.<br />
For SM1B starter with BF09A, SMX31 41 ❶ 15.00<br />
BF12A, BF18A or BF25A contactor.<br />
Complete with cover<br />
For SM1B starter with BF26A, SMX32 41 ❶ 23.00<br />
BF32A or BF38A contactor.<br />
Complete with cover<br />
Adapter plate for full-voltage 11 SMX90 10 14.00<br />
starter with SM1B starter and BG<br />
or BF09A - BF38A contactor<br />
Adapter plate for reversing 11 SMX90 12 24.00<br />
contactor assembly with SM1B<br />
starter and BG or BF9-BF25<br />
or BF09A - BF38A contactors<br />
Adapter plate for wye-delta 11 SMX90 14 28.00<br />
starter with SM1B starter and<br />
45mm wide contactors<br />
(BF09A-BF38A-BF9C-BF25C)<br />
DIN rail for wire 11 SMX90 18 3.80<br />
bypass of contactor used<br />
with SMX90 14 plate<br />
DIN rail extension 11 SMX90 19 2.00<br />
for 55mm wide contactors<br />
Surface mount enclosures.<br />
IP40, 4in (100mm) wide 11 SMX17 10 38.00<br />
IP40 ❷, 3.3in (85mm) wide 11 SMX17 11 32.00<br />
Flush mount enclosure.<br />
IP40, 4in (100mm) wide 11 SMX17 20 24.00<br />
Accessories for enclosures.<br />
Padlockable rotary operators.<br />
IP65. Grey/Black color. 11 SMX17 30❷ 12.00<br />
For SMX17 10 and<br />
SMX17 20 enclosures<br />
IP65. Red-yellow color. 11 SMX17 35❷ 12.00<br />
For SMX17 10 and<br />
SMX17 20 enclosures<br />
Operator with emergency stop button.<br />
IP65. For SMX17 11 and 11 SMX17 40❷ 33.00<br />
SMX17 21 enclosures<br />
IP65 membrane complete with rim.<br />
For SMX17 11 enclosure 11 SMX17 45 12.00<br />
Neutral connection.<br />
For SMX17 10 and SMX17 20 11 SMX17 50 6.00<br />
Pilot lights.<br />
Green 23 NEONV❸V 18.00<br />
Red 23 NEONR❸V 18.00<br />
PG adapters for enclosures.<br />
Metal, for PG16 to 1 /2” NPT G616 3.00<br />
Plastic, for PG16 to 1 /2” NPT G617 9.00<br />
❶ To obtain IP65 degree of protection, mount the 11 SMX17 45 membrane.<br />
❷ The device obtained with this operator is not suitable for isolation per<br />
IEC/EN 60947-2 standards.<br />
❸ Complete with required voltage as follows: 24, 110 for 110/120, or 230VAC.<br />
General and operational characteristics<br />
SM1 - CONTACTOR CONNECTION<br />
The SMX90 03, SMX31 41 and SMX32 41 rigid<br />
connections electrically fasten the breaker together with<br />
the contactor forming a single-unit starter for quick<br />
installation on 35mm DIN rail (IEC/EN 60715).<br />
STARTER ASSEMBLY ADAPTER PLATES<br />
The elements consent to preassemble starters and to<br />
form trim and compact single-unit equipment for quick<br />
and easy installation.<br />
The starter adapter plates install on 35mm DIN rail<br />
(IEC/EN 60715).<br />
SURFACE MOUNT ENCLOSURE<br />
– Top or bottom entry<br />
• PG16 thread for SMX17 10;<br />
• 22.5mm knockout for SMX17 11<br />
– Rear entry<br />
• 22.5mm knockout<br />
– Holds a SM1B starter equipped with one side-mount<br />
contact block (100mm wide version only), one frontmount<br />
block and either one shunt or undervoltage<br />
release<br />
– Ground terminal included.<br />
FLUSH MOUNT ENCLOSURE<br />
– Use with starter, complete with 1 front-mount and<br />
1 side-mount blocks and one shunt or undervoltage<br />
release<br />
– Ground terminal included<br />
– Cut-out size, 4.02x5.62in (102x142.8mm).<br />
PADLOCKABLE ROTARY ACTUATOR<br />
– Suitable for SMX17 10 and SMX17 20 enclosures<br />
– Raises the degree of protection of the enclosure to<br />
IP65<br />
– 3 padlocks maximum.<br />
ACTUATOR WITH EMERGENCY PUSH-BUTTON<br />
– Suitable for SMX17 11 enclosures<br />
– Raises the degree of protection of the enclosure to<br />
IP65.<br />
Certifications and compliance<br />
UL listing for USA and Canada pending for SMX90 03,<br />
SMX31 41 and SMX32 41 connections.<br />
Compliant with standards: IEC/EN 60947-1.<br />
1<br />
11 SMX17 35<br />
11 SMX17 40<br />
11 SMX17 45<br />
Dimensions<br />
page D-2<br />
Wiring diagrams<br />
page W-2<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com<br />
Technical characteristics<br />
pages TC-2 and 3
®<br />
®<br />
®<br />
®<br />
®<br />
®<br />
TEST<br />
®<br />
®<br />
1-6<br />
Manual motor starters and protectors<br />
Add-on blocks and accessories for SM1B types<br />
electric<br />
1<br />
Combinations<br />
Front-mount contacts.<br />
Side-mount contacts.<br />
Undervoltage trip release.<br />
Shunt trip release.<br />
Side-mount contacts.<br />
Undervoltage trip release with auxiliary contacts.<br />
SMX14❶<br />
SMX16❶<br />
SMX15<br />
SMX1311❷<br />
SMX12❷<br />
SMX1311❷<br />
SMX12❷<br />
SMX11<br />
❶ Only one add-on block can be fitted on the left side of the breaker.<br />
❷ One of the following combinations can be mounted on the right side of the breaker:<br />
– One each of SMX13 11 and SMX12<br />
or one only SMX13 11<br />
or one only SMX12<br />
Three-phase connection busbars<br />
SMX90 50<br />
SMX90 35<br />
SMX90 31<br />
SMX90 34<br />
SMX90 32<br />
SMX90 33<br />
® ®<br />
® ®<br />
® ®<br />
® ®<br />
TEST TEST<br />
TEST TEST TEST<br />
TEST TEST TEST TEST<br />
TEST<br />
Three-phase connection busbar,<br />
1 3 /4 (45mm) spacing (starters<br />
without add-on blocks).<br />
SMX90 45<br />
SMX90 50<br />
SMX90 31<br />
SMX90 42<br />
SMX90 44<br />
SMX90 43<br />
® ®<br />
TEST TEST<br />
TEST<br />
TEST<br />
TEST<br />
TEST<br />
TEST<br />
® ®<br />
TEST TEST TEST<br />
Three-phase connection<br />
busbar, 2 1 /8 (54mm)<br />
spacing (starters with<br />
add-on blocks).<br />
Dimensions<br />
page D-2<br />
Wiring diagrams<br />
page W-2<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com<br />
Technical characteristics<br />
pages TC-2 and 3
®<br />
®<br />
®<br />
®<br />
®<br />
L<br />
®<br />
electric<br />
Manual motor starters and protectors<br />
Add-on blocks and accessories for SM1B types<br />
1-7<br />
Combinations<br />
Rigid starter-contactor connection and protection cover<br />
1<br />
TEST<br />
SM1B<br />
TEST<br />
SM1B<br />
TEST<br />
SM1B<br />
SMX31 41<br />
SMX32 41<br />
SMX90 03<br />
BG<br />
BF09A-BF25A<br />
BF26A-BF38A<br />
Padlockable attachment for<br />
operating lever<br />
Adjuster sealing kit<br />
Padlockable door interlock handle<br />
SMX18 14<br />
SMX18 15<br />
Lovato<br />
SMX18 10<br />
SMX18 12<br />
Surface mount enclosure SMX17 10 or SMX17 11<br />
Surface mount enclosure SMX17 11 complete with<br />
emergency stop button SMX17 40.<br />
❶<br />
SMX12...<br />
TEST<br />
SMX13...<br />
SMX15...<br />
SMX11...<br />
SMX17 40<br />
SMX16...<br />
Flush mount enclosure SMX17 20<br />
SMX14...<br />
❶ Only one contact block can be fitted on<br />
the right and on front and one release<br />
on the left.<br />
SMX17 11<br />
Dimensions<br />
page D-2<br />
Wiring diagrams<br />
page W-2<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com<br />
Technical characteristics<br />
pages TC-2 and 3
1-8<br />
Manual motor starters and protectors<br />
Add-on blocks and accessories for SM2A and SM3A types<br />
electric<br />
1<br />
11 SMX20 11<br />
11 SMX21 11<br />
11 SMX22<br />
11 SMX23 11<br />
Characteristics Catalog Price<br />
number<br />
$ each<br />
Add-on auxiliary contacts.<br />
Front mount 1 double throw 11 SMX20 11 23.00<br />
Front mount 1NO+1NC 11 SMX21 11 23.00<br />
Side mount 1NO+1NC 11 SMX22 11 23.00<br />
Side mount 2NO 11 SMX22 20 23.00<br />
Side mount 2NC 11 SMX22 02 23.00<br />
Side mount indicator 11 SMX23 11 34.00<br />
contacts (1NO+1NC) for<br />
thermal trip and (1NO+1NC)<br />
for magnetic trip ❶<br />
Undervoltage trip releases.<br />
110-127VAC 50/60Hz 11 SMX24 BC 57.00<br />
220-240VAC 50/60Hz 11 SMX24 CL 57.00<br />
380-400VAC 50/60Hz 11 SMX24 EA 57.00<br />
220-240VAC (50/60Hz) 11 SMX25 CL 72.00<br />
with early-make contacts<br />
380-400VAC (50/60Hz) 11 SMX25 EA 72.00<br />
with early-make contacts<br />
Shunt trip releases.<br />
24VAC 50/60Hz 11 SMX26 AF 57.00<br />
110-127VAC 50/60Hz 11 SMX26 BC 57.00<br />
220-240VAC 50/60Hz 11 SMX26 CL 57.00<br />
400-480VAC 50/60Hz 11 SMX26 EA 57.00<br />
Padlockable door interlock rotary operator.<br />
3 padlocks max, black 11 SMX28 05 99.00<br />
3 padlocks max, red/yellow 11 SMX28 10 99.00<br />
General and operational characteristics<br />
ADD-ON AUXILIARY BLOCKS<br />
– Snap on to the front or the left side of the starter<br />
– Maximum combination: 8 auxiliary contacts of which<br />
2 on front and 6 on the side (2 normal contacts and<br />
4 indicators)<br />
– Rated thermal current Ith: 10A (2.5A for SMX21 11)<br />
– Rated insulation voltage Ui: 690V (250V for SMX20<br />
and SMX22)<br />
– UL designation: A600 Q300 (C300 R300 for SMX20<br />
and SMX21); see page TC-3 for details.<br />
– Conductor cross section connectable (1 or 2 wires)<br />
min/max: 0.5/2.5mm 2 and AWG 18/14.<br />
UNDERVOLTAGE TRIP RELEASE<br />
– Snap on to the right side of the starter<br />
– Consumption inrush/holding: 20.2/7.2 VA; 13/2.4 W<br />
– Dropout voltage: 0.35-0.7 Us<br />
– Pickup voltage: 0.85-1.1 Us<br />
– Conductor cross section connectable (1 or 2 wires)<br />
min/max: 0.5/2.5mm 2 and AWG 18/14.<br />
SHUNT TRIP RELEASE<br />
– Snap on to the right side of the starter<br />
– Inrush consumption: 20.2VA; 13W<br />
– Operating voltage: 0.7-1.1 Us<br />
– Conductor cross section connectable (1 or 2 wires)<br />
min/max: 0.5/2.5mm 2 and AWG 18/14.<br />
Certifications and compliance<br />
For contacts and releases, UL listed, for USA and<br />
Canada, file E93601, CSA certified, file LR 703212.<br />
Compliant with standards: IEC/EN 60947-5-1.<br />
❶ See diagram on page W-2 for the exact operation.<br />
11 SMX24<br />
11 SMX25<br />
11 SMX26<br />
Dimensions<br />
page D-3<br />
Wiring diagrams<br />
page W-2<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com<br />
Technical characteristics<br />
pages TC-2 and 3
electric<br />
Manual motor starters and protectors<br />
Add-on blocks and accessories for SM2A and SM3A types<br />
1-9<br />
Mounting position<br />
1<br />
SMX24<br />
SMX25<br />
SMX26<br />
L<br />
Lovato<br />
SMX23 11<br />
SMX22<br />
SMX20 11<br />
SMX21 11<br />
Padlockable door interlock rotary operator SMX28 05 - SMX28 10<br />
L<br />
Lovato<br />
max.<br />
max ¿ 8 Ø mm 0.32in (8mm)<br />
Dimensions<br />
page D-3<br />
Wiring diagrams<br />
page W-2<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com<br />
Technical characteristics<br />
pages TC-2 and 3
1-10<br />
Manual motor starters and protectors<br />
Manual motor starter LMS25 up to 25A<br />
electric<br />
1<br />
Manual motor<br />
starter LMS25<br />
up to 25A<br />
11 LMS 25<br />
Setting range UL maximum horsepower ratings Catalog number Price<br />
of thermal trip ❶ Single-phase ❷ Three-phase<br />
120V 240V 200V 240V 480V 600V<br />
[A] [HP] [HP] [HP] [HP] [HP] [HP] $ each<br />
0.1-0.16 – – – – – – 11 LMS25 016T 85.00<br />
0.16-0.25 – – – – – – 11 LMS25 025T 85.00<br />
0.25-0.4 – – – – – – 11 LMS25 04T 85.00<br />
0.4-0.63 – – – – – – 11 LMS25 063T 85.00<br />
0.63-1 – – – – – 1<br />
/2 11 LMS25 1T 85.00<br />
1-1.6 – – – – 3<br />
/4<br />
3<br />
/4 11 LMS25 1V6T 85.00<br />
1.6-2.5 – 1<br />
/6<br />
1<br />
/2<br />
1<br />
/2 1 1 1 /2 11 LMS25 2V5T 85.00<br />
2.5-4 1<br />
/8<br />
1<br />
/4<br />
3<br />
/4 1 2 3 11 LMS25 4T 85.00<br />
4-6.3 1<br />
/4<br />
1<br />
/2 1 1 /2 1 1 /2 3 5 11 LMS25 6V3T 85.00<br />
6.3-10 1<br />
/2 1 2 3 5 7 1 /2 11 LMS25 10T 100.00<br />
10-16 1 2 3 5 10 10 11 LMS25 16T 100.00<br />
16-20 1 3 5 5 10 15 11 LMS25 20T 102.00<br />
20-25 2 3 5 7 1 /2 15 20 11 LMS25 25T 132.00<br />
❶ The appropriate thermal trip range of the manual starter should be selected on<br />
the basis of the motor nameplate full-load current since the horsepower<br />
ratings given in the table are for reference only.<br />
❷ Single-phase horsepower ratings are based on wiring the three poles in series.<br />
General characteristics<br />
The LMS25 manual motor starter is particularly suitable for<br />
controlling small operating machines.<br />
Releases and auxiliary contacts make it also suitable for<br />
more complex uses.<br />
Wall and flush-mount enclosures allow to install the LMS25<br />
starter in the most disparate environmental conditions<br />
(dust, humidity, aggressive environmental agents, etc.).<br />
Operational characteristics<br />
– Rated insulation voltage Ui: 690V<br />
– Rated impulse voltage: 6kV<br />
– Rated frequency: 50/60Hz<br />
– Maximum rated current: 25A<br />
– Number of adjustment ranges: 13 (0.1 to 25A)<br />
– Power dissipation per phase: 2-15W<br />
– Magnetic tripping: 12 In max<br />
– Thermal tripping time class: 10<br />
– Utilization category: A<br />
– Single-phase sensitive<br />
– Trip free<br />
– Mechanical life: 100,000 cycles<br />
– <strong>Electric</strong>al life 25A (AC3): 100,000 cycles<br />
– Mounting on 35mm DIN rail (IEC/EN 60715) or screw<br />
fixing<br />
– Mounting position: Any<br />
– Degree of protection: IP20.<br />
Certifications and compliance<br />
UL listed for USA and Canada, file E155982.<br />
Compliant with standards: IEC/EN 60947-1, IEC/EN 60947-2,<br />
IEC/EN 60947-4-1.<br />
Dimensions<br />
page D-3<br />
Wiring diagrams<br />
page W-2<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com<br />
Technical characteristics<br />
pages TC-2 and 3
electric<br />
Manual motor starters and protectors<br />
Add-on blocks and accessories for LMS25 types<br />
1-11<br />
11 LMH 11 LMU - 11 LMA<br />
11 SMX90 32<br />
11 SMX90 50<br />
11 LMZ111 - 11 LMZ112<br />
11 LMZ113 - 11 LMZ114<br />
11 LMZ105 11 LMZ106<br />
Description Catalog Price<br />
number<br />
$ each<br />
Add-on auxiliary contacts. Side mount.<br />
1NO + 1NC 11 LMH 11 5.00<br />
2NO 11 LMH 20 5.00<br />
1NO 11 LMH 10 5.00<br />
1NC 11 LMH 01 5.00<br />
Undervoltage trip release.<br />
To fit inside starter 11 LMU❶ 41.00<br />
Shunt trip release.<br />
To fit inside starter 11 LMA❶ 41.00<br />
Terminal block for busbar supply.<br />
For all types 11 SMX90 50 21.00<br />
Three-phase connection busbars 1 3 /4in (45mm) spacing.<br />
For 2 breakers without 11 SMX90 32 18.00<br />
side-mount contacts<br />
For 3 breakers without 11 SMX90 33 21.00<br />
side-mount contacts<br />
For 4 breakers without 11 SMX90 34 24.00<br />
side-mount contacts<br />
For 5 breakers without 11 SMX90 35 30.00<br />
side-mount contacts<br />
Three-phase connection busbars 2 1 /8in (54mm) spacing.<br />
For 2 breakers complete with 11 SMX90 42 18.00<br />
side-mount contacts<br />
For 3 breakers complete with 11 SMX90 43 21.00<br />
side-mount contacts<br />
For 4 breakers complete with 11 SMX90 44 24.00<br />
side-mount contacts<br />
For 5 breakers complete with 11 SMX90 45 30.00<br />
side-mount contacts<br />
Surface mount enclosures.<br />
IP41. 3.1in (80mm) wide 11 LMZ 112 22.00<br />
IP55. 3.1in (80mm) wide 11 LMZ 111 23.00<br />
Flush mount enclosures.<br />
IP41. 3.3in (85mm) wide 11 LMZ 114 19.00<br />
IP55. 3.3in (85mm) wide 11 LMZ 113 20.00<br />
Accessories for enclosures.<br />
Locking mechanism.<br />
3 padlocks maximum 11 LMZ 105 14.00<br />
Emergency stop button.<br />
For all types 11 LMZ 106 32.00<br />
Neutral connection.<br />
For all types 11 LMN PE 14.00<br />
Pilot light.<br />
Green 23 NEONV❷V 7.00<br />
Red 23 NEONR❷V 7.00<br />
Spare IP55 membrane complete with rim.<br />
For all types 11 LMM 4.00<br />
Adapter for PG16 to M25 entry.<br />
For LMZ111 and LMZ112 11 LM M25PG16 4.00<br />
❶ Complete with required voltage and frequency. Available voltages:<br />
24, 48, 110, 220 for 220/240, 380 for 380/415, 440 for 440/460, 480, 575VAC.<br />
➋ Indicate required voltage value as follows:<br />
24, 110 for 110/120 or 230VAC.<br />
General and operational characteristics<br />
ADD-ON AUXILIARY CONTACTS<br />
– Connectable to right or left side of starter<br />
– Maximum combination: 4 auxiliary contacts<br />
– Rated insulation voltage Ui: 500V<br />
– Rated thermal current Ith: 6A<br />
– Operational current AC15: 3.5A 230V; 2A 400V<br />
– Protection fuse (gL or gG): 6A max<br />
– Conductor cross section connectable (1 or 2 wires)<br />
min/max: 0.75-2.5mm 2 or AWG 18/14<br />
– Width of the auxiliary contacts LMH equal to 0.5<br />
standard DIN43880 modules.<br />
UNDERVOLTAGE AND SHUNT TRIP RELEASES<br />
– Must be fitted inside the motor starter.<br />
Undervoltage Shunt<br />
Rated frequency 50 or 60Hz 50 or 60Hz<br />
Release range 0.35-0.7 Us ––<br />
Operating range 0.85-1.1 Us 0.7-1.1 Us<br />
On-load factor 100% ––<br />
THREE-PHASE CONNECTION BUSBAR<br />
– Imax 63A<br />
– SMX90 3... 1 3 /4in (45mm) spacing to reduce the width to<br />
the minimum<br />
– SMX90 4... 2 1 /8in (54mm) spacing to consent to fit one<br />
side-mount auxiliary contact block on the starter<br />
– Conductor cross section connectable to terminal block<br />
for busbar supply min/max: 4/25mm 2 or AWG 10/4.<br />
TERMINAL BLOCK FOR BAR SUPPLY<br />
– Imax 63A<br />
– Conductor cross section connectable min/max: 4/25mm 2<br />
or AWG 10/4.<br />
SURFACE MOUNT ENCLOSURE<br />
– Top or bottom entry:<br />
• M25 threaded knockouts<br />
– Rear entry:<br />
• 0.6in (15.5mm) knockouts<br />
– Up to two auxiliary contact blocks may be mounted<br />
– Ground terminal included.<br />
FLUSH MOUNT ENCLOSURE<br />
– Window size 2.8x4.5in (70x115mm)<br />
– Up to two auxiliary contact blocks may be mounted<br />
– Ground terminal included.<br />
ACCESSORIES FOR ENCLOSURES<br />
Locking mechanism:<br />
– Prevents closing operation; 3 padlocks maximum.<br />
Emergency stop button:<br />
– Turn to release<br />
– Red push-button Ø 1.4in (35mm)<br />
NOTE: Once mounted on the enclosure, these accessories<br />
raise the degree of protection from IP41 to IP55.<br />
Certifications and compliance<br />
UL listed for USA and Canada, file E155982 for contacts<br />
and releases.<br />
Compliant with standards: IEC/EN 60947-1,<br />
IEC/EN 60947-5-1.<br />
1<br />
11 LMNPE<br />
23 NEON...V<br />
Dimensions<br />
page D-3<br />
Wiring diagrams<br />
page W-2<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com<br />
Technical characteristics<br />
pages TC-2 and 3
PAGE 2-2<br />
PANEL MOUNTING PLATE VERSION<br />
• 30A to 100A ratings<br />
• To complete with extension and handle.<br />
ACCESSORIES<br />
• Padlockable IP65 handles<br />
• Door interlock extensions.<br />
PAGE 2-3<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com
2<br />
DISCONNECT SWITCHES<br />
30, 40, 60, 80 and 100 Amp ratings<br />
Suitable for motor disconnect<br />
Three-pole door interlock version<br />
Modular and compact size<br />
Door mounting kit<br />
PLANET -SWITCH<br />
Disconnect switches<br />
SEC. PAGE<br />
Three pole switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2- 2<br />
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2- 3<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com
2-2<br />
Disconnect switches<br />
electric<br />
2<br />
Three-pole<br />
switches<br />
GUS040A<br />
General AC23A Description Catalog Price<br />
purpose rating<br />
number<br />
400V<br />
[A] [kW] $ each<br />
For panel plate or DIN rail mounting. To be completed with<br />
extension and handle. Suitable to break all lines.<br />
30 10 3-pole switch body GUS030A 50.00<br />
40 13 3-pole switch body GUS040A 55.30<br />
60 22 3-pole switch body GUS060A 68.00<br />
80 35 3-pole switch body GUS080A 82.90<br />
100 37 3-pole switch body GUS100A 110.20<br />
HORSEPOWER RATINGS<br />
Rated voltage 1 phase 2 or 3 phase<br />
[VAC]<br />
GUS030A motor ratings.<br />
110-120 2 2<br />
200-208<br />
230-240<br />
3 7 1 /2<br />
265-277 3 7 1 /2<br />
380-415 5 10<br />
440-480 7 1 /2 15<br />
550-600 10 20<br />
GUS040A motor ratings.<br />
110-120 2 2<br />
200-208<br />
230-240<br />
3 7 1 /2<br />
General characteristics<br />
– Suitable as motor disconnect and motor controller<br />
– Use with design B, C, D motors<br />
– Fixing on panel mounting plate<br />
– Mounting on 35mm DIN rail (IEC/EN 60715)<br />
– Padlockable in 0 position with no tools<br />
Opertional characteristics<br />
– Rated insulation voltage Ui: 690V<br />
– Rated impulse withstand voltage Uimp: 8kV<br />
– Rated short-time withstand current (1s) Icw: 1260A<br />
– Tightening torque: 35 inlb/4Nm<br />
– Maximum voltage for motors, general use and<br />
resistive loads<br />
• 600V for GUS30, GUS40 and GUS80<br />
• 480V for GUS60 and GUS100<br />
– Conductor cross section (1 wire) min/max:<br />
2.5/16mm 2 or AWG 14/4 if stranded; 2.5/6mm 2 or<br />
AWG 14/10 if solid.<br />
Certifications and compliance<br />
UL listed for USA and Canada, File E155982.<br />
Compliant with standards: IEC/EN 60947-1,<br />
IEC/EN 60947-3 and UL508.<br />
265-277 3 7 1 /2<br />
380-415 5 10<br />
440-480 7 1 /2 20<br />
550-600 10 25<br />
GUS060A motor ratings.<br />
110-120 2 2<br />
200-208 5 10<br />
230-240 5 10<br />
265-277 5 10<br />
380-415 7 1 /2 15<br />
440-480 10 25<br />
GUS080A motor ratings.<br />
110-120 3 2<br />
200-208 7 1 /2 15<br />
230-240 10 20<br />
265-277 10 20<br />
380-415 15 30<br />
440-480 20 40<br />
550-600 30 50<br />
GUS100A motor ratings.<br />
110-120 5 2<br />
200-208 10 20<br />
230-240 15 25<br />
265 15 25<br />
277 15 30<br />
380-415 20 40<br />
440-480 30 50<br />
Accessories<br />
page 2-3<br />
Dimensions<br />
page D-4<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com
OFF<br />
electric<br />
Disconnect switches 2-3<br />
Accessories<br />
GUSH2<br />
Characteristics Catalog Price<br />
number<br />
$ each<br />
Handles.<br />
Black padlockable IP65 handle GUSH2 15.20<br />
Red/yellow padlockable IP65 handle GUSH3 15.20<br />
Door interlock extensions.<br />
3 1 /2in (90mm) long GUSS090 4.70<br />
6in (150mm) long GUSS150 5.50<br />
8in (200mm) long GUSS200 6.30<br />
12in (300mm) long GUSS300 8.00<br />
Front mounting adapter.<br />
Kit complete with shaft GUS00C 17.00<br />
General characteristics<br />
The handle is supplied complete with:<br />
– Front plate (bezel)<br />
– Shaft guide collar<br />
– 3 plastic-threading screws, one of which to attach the<br />
front plate to the panel and the other two to attach the<br />
collar to the front plate<br />
– Rotary knob with gasket.<br />
Certifications and compliance<br />
UL listed for USA and Canada, File E155982.<br />
Compliant with standards: IEC/EN 60947-1,<br />
IEC/EN 60947-3 and UL508.<br />
2<br />
ON<br />
GUSS150<br />
Dimensions<br />
page D-4<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com
PAGE 3-4<br />
THREE-POLE CONTACTORS<br />
• Ith ratings in AC1 duty at ≤40°C: 16A to 1600A<br />
• Ie ratings in AC3 440V duty: 6A to 630A<br />
• Power ratings in AC3 400V duty: 2.2kW to<br />
335kW<br />
• AC or DC control coil.<br />
PAGE 3-6<br />
FOUR-POLE CONTACTORS<br />
• Ith ratings in AC1 duty at ≤40°C: 20A to 1600A<br />
• Power ratings in AC3 400V duty: 14kW to<br />
950kW<br />
• AC or DC control coil.<br />
PAGE 3-8<br />
CONTACTORS FOR POWER FACTOR CORRECTION<br />
• With limiting resistors included<br />
• Power ratings at 400V: 8kvar to 60kvar<br />
• AC control coil.<br />
PAGE 3-9<br />
FOUR-POLE CONTACTORS WITH 2NO+2NC AND 4NC<br />
MAIN POLES<br />
• Ith ratings in AC1 duty at ≤40°C: 20A to 60A<br />
• AC or DC control coil.<br />
PAGE 3-9<br />
FOUR-POLE CONTACTORS<br />
WITH 4NC MAIN POWER POLES<br />
• Ith ratings in AC1 duty at ≤40°C: 25 to 40A<br />
• AC or DC control coil.<br />
PAGE 3-10<br />
CONTROL RELAYS<br />
• AC, DC or low consumption supply coil<br />
• Screw or Faston termination<br />
• 4, 8 or 11 auxiliary contact composition.<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com
3<br />
IEC STYLE CONTACTORS<br />
IEC style contactors - long<br />
electrical and mechanical life<br />
Complete range from<br />
mini-contactors to 630 Amp<br />
inductive AC3 ratings<br />
Wide range coils +10% to -20%<br />
Finger safe terminals<br />
Four-pole versions available<br />
2NO + 2NC and 4NC power pole<br />
versions available<br />
Extensive assortment of add-on<br />
blocks and accessories<br />
PLANET -SWITCH<br />
SEC. PAGE<br />
Contactors<br />
Three-pole . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3- 4<br />
Four-pole . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3- 6<br />
For power factor correction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3- 8<br />
Special four-pole. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3- 9<br />
Control relays . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3- 10<br />
Add-on blocks and accessories<br />
For BG series mini-contactors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3- 12<br />
For BF series contactors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3- 14<br />
For B series contactors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3- 22<br />
Positively guided contacts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3- 24<br />
Spare parts<br />
AC coils for contactors BF00A and BF09A-BF38A . . . . . . . . . . . . . . . . . . . . . . . . . . 3- 26<br />
AC coils for contactors BF50-BF110 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3- 27<br />
DC coils for contactors BF...C . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3- 28<br />
AC/DC coils for contactors B115-B1600 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3- 29<br />
Main contacts for BF series contactors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3- 30<br />
Main contacts and arc chutes for B series contactors. . . . . . . . . . . . . . . . . . . . . . . . 3- 31<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com
3-2<br />
IEC style contactors<br />
General information - IEC contactors<br />
electric<br />
Lovato <strong>Electric</strong> comprehensive line of contactors can be divided in to three basic configurations. Each of these have<br />
unique features but all are designed for long life and have finger-safe protection. Lovato <strong>Electric</strong> facilities, where these<br />
contactors are manufactured, work under ISO 9001 quality conditions, per IQNet certification since 1992 and constantly<br />
maintained by passing yearly quality assurance audits. The design and manufacture of the contactors and accessories<br />
have taken into consideration the most demanding international standards requirements.<br />
3<br />
BG series<br />
6A/3HP - 12A/7.5HP<br />
• Highly conductive auxiliary contacts with four contact points<br />
• AC and DC versions of same size<br />
• Quick connect - snap on accessory mounting<br />
• Distinct contact status indication<br />
• Up to four auxiliary contacts can be mounted<br />
• Mechanical interlock only 5mm deep<br />
• Low DC consumption interface version<br />
• Positively guided contacts (mechanically-linked per IEC)<br />
3 poles 4 poles<br />
Ie (AC3) AC DC Ith (AC1) AC DC<br />
BG06 6A ● ● –– –– ––<br />
BG09 9A ● ● 20A ● ●<br />
BGF09 9A ● ● 20A ● ●<br />
BGP09 9A ● ● 20A ● ●<br />
BG12 12A ● ● –– –– ––<br />
BF series<br />
9A/5HP - 110A/75HP<br />
• 4 different contactor frame sizes up to 75HP<br />
• Anti-shock magnetic core design<br />
• Straight through wiring<br />
• Captive raised terminal screws to reduce wiring time<br />
• Wide coil operating range<br />
• Coil removable without disconnecting power wiring<br />
• Oversized main contacts<br />
• Easy contact inspection and replacement<br />
• Special main pole configurations<br />
• Specific version for power factor correction systems<br />
• Positively guided contacts (mechanically-linked per IEC)<br />
3 poles 4 poles<br />
Ie (AC3) AC DC Ith (AC1) AC DC<br />
BF09 9A ● ● 25A ● ●<br />
BF12 12A ● ● 28A ● ––<br />
BF16 16A –– ● 25A –– ●<br />
BF18 18A ● –– 32A ● ––<br />
BF20 20A –– ● –– –– ––<br />
BF25 25A ● ● 32A –– ●<br />
BF26 26A ● –– 45A ● ––<br />
BF32 32A ● ● –– –– ––<br />
BF38 38A ● –– 56A ● ––<br />
BF40 40A –– ● 60A –– ●<br />
BF50 50A ● ● 90A ● ––<br />
BF65 65A ● ● 110A ● ●<br />
BF80 80A ● ● 125A ● ●<br />
BF95 95A ● ● –– –– ––<br />
BF110 110A ● ● –– –– ––<br />
B series<br />
110A/75HP -<br />
630A/500HP<br />
• 3 frame sizes offering 11 different contactors<br />
• Coil operate indifferently on AC or DC supply voltage<br />
• Coil with low in-rush and holding<br />
• Coil removable without disconnecting power wiring<br />
• Red indicator when contactor is energized<br />
• Unique right-angle magnet design - limits contact bounce<br />
• Safety feature prevents contactor to be energized without arc chute in<br />
place and locked<br />
• Convertible auxiliary contact block (2NO + 1NC or 1NO + 2NC),<br />
maximum of 4 blocks per contactor for a total of 12 contacts<br />
• Contactor terminals furnished with bolt, washer and nut<br />
• Simple horizontal or vertical interlock<br />
• Positively guided contacts (mechanically-linked per IEC)<br />
3 poles 4 poles<br />
Ie (AC3) AC DC Ith (AC1) AC DC<br />
B115 110A ● ● 160A ● ●<br />
B145 150A ● ● 250A ● ●<br />
B180 185A ● ● 275A ● ●<br />
B250 265A ● ● 350A ● ●<br />
B310 320A ● ● 450A ● ●<br />
B400 420A ● ● 550A ● ●<br />
B500 520A ● ● 700A ● ●<br />
B630 630A ● ● 800A ● ●<br />
B630 1000 ❶ ● ● 1000A ● ●<br />
B1250 ❶ ● –– 1250A ● ––<br />
B1600 ❶ ● –– 1600A ● ––<br />
❶ For AC1 duty only.<br />
Non-reversing and<br />
reversing IEC<br />
starters<br />
Contactors can be combined with either manual motor starters of the SM series, providing thermal and magnetic protection up to 100A, or<br />
single or three-pole thermal bimetallic overload relays, with or without single-phase protection up to 420A, to obtain non-reversing or<br />
reversing starters. Equipment can be assembled together or independently mounted through the use of specifically designed accessories.<br />
Non-reversing starter Non-reversing starter Reversing starter<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com
electric<br />
IEC style contactors<br />
Contactors BF00, BF09A-BF38A<br />
3-3<br />
Simplicity<br />
4-TERMINAL COIL<br />
Connecting cables can be coupled to<br />
the coil both on the line and load ends<br />
of the contactor.<br />
SIDE ADD-ON FOURTH POLE<br />
For the 45A and 55A AC1 ratings, a side-mount<br />
fourth power pole can be snapped on the threepole<br />
contactor.<br />
This solution helps to optimize Inventory.<br />
.<br />
MECHANICAL INTERLOCK<br />
Smaller contactors, 9 to 25A in AC3, can be<br />
mechanically and electrically interlocked with<br />
larger contactors, 26 to 38A AC3.<br />
The new BFX50 02 mechanical interlock includes<br />
two built-in NC auxiliary contacts to make the<br />
electrical interlock as well.<br />
A1<br />
A1<br />
A2<br />
A2<br />
STARTER ASSEMBLY<br />
The assembly and wiring of<br />
electromechanical starters is<br />
extremely fast and reliable.<br />
Versatile electrical and<br />
mechanical connecting<br />
systems provide easy and<br />
foolproof assembly of<br />
compact starters.<br />
EFFORTLESS THERMAL<br />
OVERLOAD RELAY LINK<br />
During the connection of the<br />
thermal overload relay to the<br />
contactor, its auxiliary contact<br />
is simultaneously linked to the<br />
contactor coil terminal rigid<br />
connector.<br />
The complete overload relay<br />
fixing is obtained with one<br />
single operation and without<br />
other connections.<br />
TERMINAL ADAPTABILITY<br />
Terminals are suitable for every type of cable: flexible, rigid,<br />
according to AWG standards and interlocked with any type<br />
of cable terminal.<br />
Power pole, auxiliary and coil screws can be tightened using<br />
one single type of screwdriver.<br />
3<br />
35MM DIN RAIL MOUNTING AND FIXING<br />
Contactor mounting on and removal from a 35mm DIN rail<br />
are tool less operations and are done by simply applying<br />
pressure on the contactor.<br />
SNAP-ON INSTALLATION<br />
Mounting and removal of the add-on auxiliary contacts and<br />
accessories, along with contactor coil replacement are quick<br />
and easy operations and are done with no tools.<br />
Safety<br />
FRONT PROTECTION COVER FOR<br />
MANUAL STARTERS - CONTACTOR<br />
CONNECTIONS<br />
The front cover, fixed between manual<br />
starters and contactor, provide protection<br />
to the connections.<br />
RUBBER PAD INSERT FOR NO DIN<br />
RAIL SLIDING<br />
A rubber insert prevents the<br />
contactors from sliding on the<br />
35mm DIN rail even when out of<br />
tolerance or mounted vertically.<br />
CONNECTION SECURITY -<br />
IP20<br />
The ease of terminal access<br />
and space is combined with<br />
IP20 finger safety, to prevent<br />
touching of live parts.<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com
3-4<br />
IEC style contactors<br />
Three-pole non-reversing contactors with operating coil in AC<br />
electric<br />
3<br />
BG06A-BG09A-<br />
BG12A<br />
BF09A-BF12A-<br />
BF18A-BF25A<br />
BF26A-BF32A-<br />
BF38A<br />
BF50-BF65-BF80<br />
BF95-BF110<br />
Maximum horsepower ratings UL UL Maximum current<br />
Single phase Three phase Amp resistive Inductive Resistive<br />
120V 240V 200V 240V 480V 600V rating Amps AC3 AC1<br />
[HP] [HP] [HP] [HP] [HP] [HP] [A] [A] [A] [A]<br />
1<br />
/3 1 1 1 /2 2 3 3 16 –– 6 16<br />
1<br />
/2 1 1 /2 2 3 5 5 20 –– 9 20<br />
1<br />
/2 1 1 /2 2 3 5 5 20 –– 9 20<br />
1<br />
/2 1 1 /2 2 3 5❷ –– 20 –– 9 20<br />
1<br />
/2 1 1 /2 3 3 7 1 /2 10 20 –– 12 20<br />
3<br />
/4 2 3 3 5 7 1 /2 25 –– 9 25<br />
1 2 5 5 7 1 /2 10 28 –– 12 28<br />
1 3 5 5 10 15 32 –– 18 32<br />
2 3 7 1 /2 7 1 /2 15 15 32 –– 25 32<br />
2 5 7 1 /2 7 1 /2 15 20 45 –– 26 45<br />
3 7 1 /2 10 10 20 25 55 –– 32 56<br />
3 7 1 /2 10 15 30 30 55 –– 38 56<br />
5 10 10 15 30 40 90 –– 50 90<br />
–– –– 20 25 50 60 110 –– 65 110<br />
–– –– 25 30 60 75 125 –– 80 125<br />
–– –– 30 30 60 75 125 –– 95 125<br />
–– –– 30 40 75 100 125 –– 110 125<br />
–– –– 30 40 75 100 110 160 110 160<br />
–– –– 50 50 100 125 150 220 150 250<br />
–– –– 60 75 150 150 180 260 185 275<br />
–– –– 75 100 200 250 250 350 265 350<br />
–– –– 100 125 250 300 315 400 320 450<br />
–– –– 125 150 350 400 400 450 420 550<br />
–– –– –– –– –– –– No UL No UL 520 700<br />
–– –– –– –– –– –– No UL No UL 630 800<br />
–– –– –– –– –– –– No UL No UL None 1000<br />
–– –– –– –– –– –– No UL No UL None 1250<br />
–– –– –– –– –– –– No UL No UL None 1600<br />
B115-B145-B180-B250<br />
B310-B400-B500-B630<br />
B1250-B1600<br />
Incorporated Type of Catalog number Price<br />
auxiliary termination<br />
contacts<br />
AC coil<br />
NO NC $ each<br />
1❺ 0 Clamp-screw 11 BG06 10 A ❶ 49.00<br />
0 1❺ 11 BG06 01 A ❶ 49.00<br />
1❺ 0 Clamp-screw 11 BG09 10 A ❶❻ 60.00<br />
0 1❺ 11 BG09 01 A ❶❻ 60.00<br />
1❺ 0 Faston 11 BGF09 10 A ❶ 70.00<br />
0 1❺ 11 BGF09 01 A ❶ 70.00<br />
1❺ 0 Rear PCB solder pin 11 BGP09 10 A ❶❷ 70.00<br />
0 1❺ 11 BGP09 01 A ❶❷ 70.00<br />
1❺ 0 Clamp-screw 11 BG12 10 A ❶ 76.00<br />
0 1❺ 11 BG12 01 A ❶ 76.00<br />
1❺ 0 Clamp-screw BF09 10A ❶ 81.00<br />
0 1❺ BF09 01A ❶ 81.00<br />
1❺ 0 Clamp-screw BF12 10A ❶ 102.00<br />
0 1❺ BF12 01A ❶ 102.00<br />
1❺ 0 Clamp-screw BF18 10A ❶ 117.00<br />
0 1❺ BF18 01A ❶ 117.00<br />
1❺ 0 Clamp-screw BF25 10A ❶ 130.00<br />
0 1❺ BF25 01A ❶ 130.00<br />
–– –– Clamp-screw BF26 00A ❶ 150.00<br />
–– –– Clamp-screw BF32 00A ❶ 154.00<br />
–– –– Clamp-screw BF38 00A ❶ 188.00<br />
–– –– Lug-clamp 11 BF50 00 ❶ 238.00<br />
–– –– Lug-clamp 11 BF65 00 ❶ 308.00<br />
–– –– Lug-clamp 11 BF80 00 ❶ 362.00<br />
–– –– Lug-clamp 11 BF95 00 ❶ 388.00<br />
–– –– Lug-clamp 11 BF110 00 ❶ 424.00<br />
–– –– Screw-nut 11 B115 00 ❸ 541.00<br />
–– –– Screw-nut 11 B145 00 ❸ 770.00<br />
–– –– Screw-nut 11 B180 00 ❸ 1080.00<br />
–– –– Screw-nut 11 B250 00 ❸ 1318.00<br />
–– –– Screw-nut 11 B310 00 ❸ 1859.00<br />
–– –– Screw-nut 11 B400 00 ❸ 2318.00<br />
–– –– Screw-nut 11 B500 00 ❸ 4522.00<br />
–– –– Screw-nut 11 B630 00 ❸ 6390.00<br />
–– –– Screw-nut 11 B630 1000 00 ❸ 7056.00<br />
2 4 Screw-nut 11 B1250 24 ❹ ❹<br />
2 4 Screw-nut 11 B1600 24 ❹ ❹<br />
❶ Complete catalog number with coil digit per following table.<br />
AC coil digit Voltage range<br />
02460 24V 60Hz<br />
12060 120V 60Hz<br />
23060 200-240V 60Hz<br />
46060 440-480V 60Hz<br />
57560 575V 60Hz<br />
Other coil voltage and frequency values are available on request.<br />
NOTE: No coil change or replacement is possible for BG types.<br />
❷ Limited to 300V UL rating only. For other type suitable up to<br />
600V UL rating, contact Sales & Technical Support for details and<br />
pricing.<br />
❸ Complete catalog number with coil digit per following table.<br />
Voltage range<br />
Coil digit<br />
AC/DC<br />
024 24V<br />
110 110-125V<br />
220 220-240V<br />
460 440-480V<br />
Other coil voltage values are available on request.<br />
24V type is not possible for B500-B1600 contactors.<br />
❹ Complete catalog number with coil digit 110 for 110-125VAC, 220<br />
for 220-240VAC or 460 for 440-480VAC only. Contact Sales &<br />
Technical Support for pricing.<br />
❺ Highly conductive auxiliary contact.<br />
Positively guided contacts<br />
See page 3-24 or TC-26 for contactors with NC contacts.<br />
See page 3-25 or TC-27 for add-on auxiliary contacts.<br />
Certifications and compliance<br />
BG mini-contactors: UL listed for USA and Canada,<br />
file E93602 except for BFP09 which is UL Recognized for<br />
USA and Canada, file E93602, with 300V rating maximum.<br />
BF contactors: UL listed for USA and Canada, file E93602.<br />
BF50-BF95 types are also CSA certified, file LR 54332-1<br />
and LR 54332-26.<br />
B115-B400 contactors: UL listed for USA and Canada, file<br />
E93602; CSA certified, file LR 54332-1 and LR 54332-26.<br />
B500-B600 contactors: UL listed for USA and Canada<br />
pending completion.<br />
Compliant with standards: IEC/EN 60947-1,<br />
IEC/EN 60947-4-1.<br />
Add-on blocks/Accessories<br />
pages 3-12 to 23<br />
Spare parts<br />
pages 3-26 to 31<br />
Dimensions<br />
pages D-4 to 10<br />
Wiring diagrams<br />
page W-2<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com<br />
Technical characteristics<br />
pages TC-4 to 31
electric<br />
IEC style contactors<br />
Three-pole non-reversing contactors with operating coil in DC<br />
3-5<br />
BG06D-BG09D BF9C-BF12C BF20C-BF25C BF32C-BF40C BF50C-BF65C-BF80C B115-B145-B180-B250<br />
BG12D<br />
BF16C BF95C-BF110C B310-B400-B500-B630<br />
B630 1000<br />
Maximum horsepower ratings UL UL Maximum current Incorporated Type of Catalog number Price<br />
Single phase Three phase Amp resistive Inductive Resistive auxiliary termination<br />
120V 240V 200V 240V 480V 600V rating Amps AC3 AC1 contacts<br />
AC coil<br />
[HP] [HP] [HP] [HP] [HP] [HP] [A] [A] [A] [A] NO NC $ each<br />
1<br />
/3 1 1 1 /2 2 3 3 16 –– 6 16 1❹ 0 Clamp-screw 11 BG06 10 D ❶ 65.00<br />
0 1❹ 11 BG06 01 D ❶ 65.00<br />
1<br />
/2 1 1 /2 2 3 5 5 20 –– 9 20 1❹ 0 Clamp-screw 11 BG09 10 D ❶ 80.00<br />
0 1❹ 11 BG09 01 D ❶ 80.00<br />
1<br />
/2 1 1 /2 2 3 5 5 20 –– 9 20 1❹ 0 Clamp-screw 11 BG09 10 L ❷ 96.00<br />
0 1❹ 11 BG09 01 L ❷ 96.00<br />
1<br />
/2 1 1 /2 2 3 5 5 20 –– 9 20 1❹ 0 Faston 11 BGF09 10 D ❶ 95.00<br />
0 1❹ 11 BGF09 01 D ❶ 95.00<br />
1<br />
/2 1 1 /2 2 3 5 5 20 –– 9 20 1❹ 0 Faston 11 BGF09 10 L ❷ 105.00<br />
0 1❹ 11 BGF09 01 L ❷ 105.00<br />
1<br />
/2 1 1 /2 2 3 5❺ –– 20 –– 9 20 1❹ 0 Rear PCB solder pin 11 BGP09 10 D ❶❺ 93.00<br />
0 1❹ 11 BGP09 01 D ❶❺ 93.00<br />
1<br />
/2 1 1 /2 3 3 7 1 /2 10 20 –– 12 20 1❹ 0 Clamp-screw 11 BG12 10 D ❶ 93.00<br />
0 1❹ 11 BG12 01 D ❶ 93.00<br />
3<br />
/4 2 3 3 5 7 1 /2 22 –– 12 25 1❹ 0 Clamp-screw 11 BF9C 10 ❶ 106.00<br />
0 1❹ 11 BF9C 01 ❶ 106.00<br />
1 2 5 5 7 1 /2 10 24 –– 12 25 1❹ 0 Clamp-screw 11 BF12C 10 ❶ 131.00<br />
0 1❹ 11 BF12C 01 ❶ 131.00<br />
1 2 5 5 7 1 /2 10 24 –– 12 25 1 0 Clamp-screw 11 BF16C 10 ❶ 139.00<br />
0 1 11 BF16C 01 ❶ 139.00<br />
1 1 /2 3 5 5 10 15 32 –– 20 40 1 0 Clamp-screw 11 BF20C 10 ❶ 147.00<br />
0 1 11 BF20C 01 ❶ 147.00<br />
2 5 7 1 /2 7 1 /2 15 20 40 –– 25 40 –– –– Clamp-screw 11 BF25C 00 ❶ 165.00<br />
–– –– 11 BF25C 00 ❶ 165.00<br />
3 7 1 /2 7 1 /2 10 20 25 52 –– 32 55 –– –– Clamp-screw 11 BF32C 00 ❶ 198.00<br />
3 7 1 /2 10 15 30 30 52 –– 40 60 –– –– Clamp-screw 11 BF40C 00 ❶ 237.00<br />
5 10 10 15 30 40 90 –– 50 90 –– –– Lug-clamp 11 BF50C 00 ❶ 276.00<br />
–– –– 20 25 50 60 110 –– 65 110 –– –– Lug-clamp 11 BF65C 00 ❶ 347.00<br />
–– –– 25 30 60 75 125 –– 80 125 –– –– Lug-clamp 11 BF80C 00 ❶ 405.00<br />
–– –– 30 30 60 75 125 –– 95 125 –– –– Lug-clamp 11 BF95C 00 ❶ 451.00<br />
–– –– 30 40 75 100 125 –– 110 125 –– –– Lug-clamp 11 BF110C 00 ❶ 491.00<br />
–– –– 30 40 75 100 110 160 110 160 –– –– Screw-nut 11 B115 00 ❸ 541.00<br />
–– –– 50 50 100 125 150 220 150 250 –– –– Screw-nut 11 B145 00 ❸ 770.00<br />
–– –– 60 75 150 150 180 260 185 275 –– –– Screw-nut 11 B180 00 ❸ 1008.00<br />
–– –– 75 100 200 250 250 350 265 350 –– –– Screw-nut 11 B250 00 ❸ 1318.00<br />
–– –– 100 125 250 300 315 400 320 450 –– –– Screw-nut 11 B310 00 ❸ 1859.00<br />
–– –– 125 150 350 400 400 450 420 550 –– –– Screw-nut 11 B400 00 ❸ 2318.00<br />
–– –– –– –– –– –– No UL No UL 520 700 –– –– Screw-nut 11 B500 00 ❸ 4522.00<br />
–– –– –– –– –– –– No UL No UL 630 800 –– –– Screw-nut 11 B630 00 ❸ 6390.00<br />
–– –– –– –– –– –– No UL No UL None 1000 –– –– Screw-nut 11 B630 1000 00 ❸ 7056.00<br />
❶ Complete the catalog number with coil digit.<br />
❸ Complete catalog number with coil digit per following table.<br />
Standard voltages (coil digit) are: 024-110V.<br />
Certifications and compliance<br />
Voltage range<br />
Other coil voltage values are available on request.<br />
Coil digit<br />
BG mini-contactors: UL listed for USA and Canada,<br />
AC/DC<br />
NOTE: No coil change or replacement is possible for BG<br />
024 24V<br />
file E93602 except for BFP09 which is UL Recognized for<br />
mini-contactors.<br />
110 110-125V<br />
USA and Canada, file E93602, with 300V rating maximum.<br />
❷ Low-consumption version.<br />
220 220-240V<br />
BF contactors: UL listed for USA and Canada, file E93602.<br />
No additional auxiliary contacts or the mechanical interlock<br />
460 440-480V<br />
BF50-BF95 types are also CSA certified, file LR 54332-1<br />
BGX50 00 can be mounted.<br />
Other coil voltage values are available on request.<br />
and LR 54332-26.<br />
Complete the catalog number with coil digit.<br />
24V type is not possible for B500-B630 1000 contactors.<br />
Standard voltages (coil digit) are: 024-048V.<br />
❹ Highly conductive auxiliary contact.<br />
B115-B400 contactors: UL listed for USA and Canada, file<br />
NOTE: No coil change or replacement is possible.<br />
❺ Limited to 300V UL rating only. For other type suitable up to 600V E93602; CSA certified, file LR 54332-1 and LR 54332-26.<br />
UL rating, contact Sales & Technical Support for details and pricing. B500-B600 contactors: UL listed for USA and Canada<br />
Positively guided contacts<br />
pending completion.<br />
See page 3-24 or TC-26 for contactors with NC contacts.<br />
See page 3-25 or TC-27 for add-on auxiliary contacts.<br />
Compliant with standards: IEC/EN 60947-1, IEC/EN 60947-4-1.<br />
3<br />
Add-on blocks/Accessories<br />
pages 3-12 to 23<br />
Spare parts<br />
pages 3-26 to 31<br />
Dimensions<br />
pages D-4 to 10<br />
Wiring diagrams<br />
page W-2<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com<br />
Technical characteristics<br />
pages TC-4 to 31
3-6<br />
IEC style contactors<br />
Four-pole non-reversing contactors with operating coil in AC<br />
electric<br />
3<br />
BG09 T4A<br />
BF09 T4A<br />
BF12A T4A<br />
BF18 T4A<br />
BF26 T4A<br />
BF38 T4A<br />
BF50 40<br />
BF65 40<br />
BF80 40<br />
B115 4 - B145 4 - B180 4<br />
B250 4 - B310 4 - B400 4<br />
B500 4 - B630 4<br />
B1250-B1600 4<br />
UL UL Maximum current Operating current (AC1) Type of Catalog number Price<br />
Amp resistive Inductive Resistive ≤55°C ≤70°C termination<br />
rating Amps AC3 AC1 (131°F) (158°F)<br />
[A] [A] [A] [A] [A] [A] $ each<br />
20 –– 9 20 18 15 Clamp-screw 11 BG09 T4A ❶ 62.00<br />
20 –– 9 20 18 15 Faston 11 BGF09 T4A ❶ 70.00<br />
20 –– 9 20 18 15 PCB solder pin 11 BGP09 T4A ❶❷ 68.00<br />
25 –– 9 25 20 18 Clamp-screw BF09 T4A ❶ 90.00<br />
28 –– 12 28 23 20 Clamp-screw BF12 T4A ❶ 111.00<br />
32 –– 18 32 26 23 Clamp-screw BF18 T4A ❶ 142.00<br />
45 –– 26 45 36 32 Clamp-screw BF26 T4A ❶ 162.00<br />
56 –– 38 56 45 40 Clamp-screw BF38 T4A ❶ 269.00<br />
90 –– 50 90 80 65 Lug-clamp 11 BF50 40 ❶ 297.00<br />
110 –– 65 110 90 70 Lug-clamp 11 BF65 40 ❶ 398.00<br />
125 –– 80 125 100 80 Lug-clamp 11 BF80 40 ❶ 463.00<br />
110 160 110 160 150 110 Screw-nut 11 B115 4 00 ❸ 682.00<br />
150 220 150 250 235 190 Screw-nut 11 B145 4 00 ❸ 911.00<br />
180 260 185 275 250 200 Screw-nut 11 B180 4 00 ❸ 1398.00<br />
250 350 265 350 300 250 Screw-nut 11 B250 4 00 ❸ 1682.00<br />
315 400 320 450 370 300 Screw-nut 11 B310 4 00 ❸ 2467.00<br />
400 450 420 550 430 360 Screw-nut 11 B400 4 00 ❸ 2841.00<br />
No UL No UL 520 780 550 500 Screw-nut 11 B500 4 00 ❸ 5208.00<br />
No UL No UL 630 800 640 540 Screw-nut 11 B630 4 00 ❸ 7098.00<br />
No UL No UL None 1000 850 700 Screw-nut 11 B630 1000 4 00 ❸ 7957.00<br />
No UL No UL None 1250 1050 880 Screw-nut 11 B1250 4 24 ❹ ❹<br />
No UL No UL None 1600 1360 1120 Screw-nut 11 B1600 4 24 ❹ ❹<br />
❶ Complete catalog number with coil digit per following table.<br />
AC coil digit Voltage range<br />
02460 24V 60Hz<br />
12060 120V 60Hz<br />
23060 200-240V 60Hz<br />
46060 440-480V 60Hz<br />
57560 575V 60Hz<br />
Other coil voltage and frequency values are available on request.<br />
NOTE: No coil change or replacement is possible for BG types.<br />
❷ Limited to 300V UL rating only. For other type suitable up to<br />
600V UL rating, contact Sales & Technical Support for details<br />
and pricing.<br />
❸ Complete catalog number with coil digit per following table.<br />
Coil digit<br />
Voltage range<br />
AC/DC<br />
024 24V<br />
110 110-125V<br />
220 220-240V<br />
460 440-480V<br />
Other coil voltage values are available on request.<br />
24V type is not possible for B500-B1600 contactors.<br />
❹ Complete catalog number with coil digit 110 for 110-125VAC,<br />
220 for 220-240VAC or 460 for 440-480VAC only. Contact Sales<br />
& Technical Support for pricing.<br />
Positively guided contacts<br />
See page 3-24 or TC-27 for add-on auxiliary contacts.<br />
Certifications and compliance<br />
BG mini-contactors: UL listed for USA and Canada,<br />
file E93602 except for BFP09 which is UL Recognized for<br />
USA and Canada, file E93602, with 300V rating<br />
maximum.<br />
BF contactors: UL listed for USA and Canada,<br />
file E93602. BF50-BF95 types are also CSA certified,<br />
file LR 54332-1 and LR 54332-26.<br />
B115-B400 contactors: UL listed for USA and Canada,<br />
file E93602; CSA certified, file LR 54332-1 and<br />
LR 54332-26.<br />
B500-B600 contactors: UL listed for USA and Canada<br />
pending completion.<br />
Compliant with standards: IEC/EN 60947-1,<br />
IEC/EN 60947-4-1.<br />
Add-on blocks/Accessories<br />
pages 3-12 to 23<br />
Spare parts<br />
pages 3-26 to 31<br />
Dimensions<br />
pages D-4 to 10<br />
Wiring diagrams<br />
page W-2<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com<br />
Technical characteristics<br />
pages TC-4 to 31
electric<br />
IEC style contactors<br />
Four-pole non-reversing contactors with operating coil in DC<br />
3-7<br />
BG09 T4D BF9C 40<br />
BF25C 40 BF40C 40<br />
BF50C 40-BF65C 40 B115 4-B145 4-B180 4<br />
BF16C 40<br />
BF80C 40<br />
B250 4-B310 4-B400 4 B630 1000 4<br />
B500 4-B630 4<br />
UL UL Maximum current Operating current (AC1) Type of Catalog number Price<br />
Amp resistive Inductive Resistive ≤55°C ≤70°C termination<br />
rating Amps AC3 AC1 (131°F) (158°F)<br />
[A] [A] [A] [A] [A] [A] $ each<br />
20 –– 9 20 18 15 Clamp-screw 11 BG09 T4 D ❶ 82.00<br />
20 –– 9 20 18 15 Faston 11 BGF09 T4 D ❶ 98.00<br />
20 –– 9 20 18 15 PCB solder pin 11 BGP09 T4 D ❶❸ 95.00<br />
22 –– 9 25 20 18 Clamp-screw 11 BF9C 40 ❶ 114.00<br />
24 –– 16 25 20 18 Clamp-screw 11 BF12C 40 ❶ 142.00<br />
40 –– 25 40 32 28 Clamp-screw 11 BF25C 40 ❶ 202.00<br />
52 –– 40 60 5 40 Clamp-screw 11 BF40C 40 ❶ 326.00<br />
110 –– 65 110 90 70 Lug-clamp 11 BF65C 40 ❶ 456.00<br />
125 –– 80 125 100 80 Lug-clamp 11 BF80C 40 ❶ 512.00<br />
110 160 110 160 150 110 Screw-nut 11 B115 4 00 ❷ 682.00<br />
150 220 150 250 235 190 Screw-nut 11 B145 4 00 ❷ 911.00<br />
180 260 185 275 250 200 Screw-nut 11 B180 4 00 ❷ 1398.00<br />
250 350 265 350 300 250 Screw-nut 11 B250 4 00 ❷ 1682.00<br />
315 400 320 450 370 300 Screw-nut 11 B310 4 00 ❷ 2467.00<br />
400 450 420 550 430 360 Screw-nut 11 B400 4 00 ❷ 2841.00<br />
No UL No UL 520 780 550 500 Screw-nut 11 B500 4 00 ❷ 5208.00<br />
No UL No UL 630 800 640 540 Screw-nut 11 B630 4 00 ❷ 7098.00<br />
No UL No UL None 1000 850 700 Screw-nut 11 B630 1000 4 00 ❷ 7957.00<br />
3<br />
❶ Complete the catalog number with coil digit.<br />
Standard voltages (coil digit) are: 024-110V.<br />
Other coil voltage values are available on request.<br />
❷ Complete catalog number with coil digit per following table.<br />
Coil digit<br />
Voltage range<br />
AC/DC<br />
024 24V<br />
110 110-125V<br />
220 220-240V<br />
460 440-480V<br />
Other coil voltage values are available on request.<br />
24V type is not possible for B500-B1600 contactors.<br />
❸ Limited to 300V UL rating only. For other type suitable up to<br />
600V UL rating, contact Sales & Technical Support for details<br />
and pricing.<br />
Positively guided contacts<br />
See page 3-25 or TC-28 for add-on auxiliary contacts.<br />
Certifications and compliance<br />
BG mini-contactors: UL listed for USA and Canada,<br />
file E93602 except for BFP09 which is UL Recognized for<br />
USA and Canada, file E93602, with 300V rating<br />
maximum.<br />
BF contactors: UL listed for USA and Canada,<br />
file E93602. BF50-BF95 types are also CSA certified,<br />
file LR 54332-1 and LR 54332-26.<br />
B115-B400 contactors: UL listed for USA and Canada,<br />
file E93602; CSA certified, file LR 54332-1 and<br />
LR 54332-26.<br />
B500-B600 contactors: UL listed for USA and Canada<br />
pending completion.<br />
Compliant with standards: IEC/EN 60947-1,<br />
IEC/EN 60947-4-1.<br />
Add-on blocks/Accessories<br />
pages 3-12 to 23<br />
Spare parts<br />
pages 3-26 to 31<br />
Dimensions<br />
pages D-4 to 10<br />
Wiring diagrams<br />
page W-2<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com<br />
Technical characteristics<br />
pages TC-4 to 31
3-8<br />
IEC style contactors<br />
Special contactors for power factor correction with AC coil<br />
electric<br />
3<br />
BFK contactors<br />
(including limiting<br />
resistors)<br />
11 BFK<br />
Maximum UL operating Catalog number Price<br />
power ❸ at<br />
240V 480V 600V ❷<br />
[kvar] [kvar] [kvar] NO $ each<br />
AC coil.<br />
4.5 8 10 1 BFK09 10A ❶ 134.00<br />
7 14 16 1 BFK12 10A ❶ 155.00<br />
9 17 20 1 BFK18 10A ❶ 175.00<br />
11 22 37.6 – BFK26 00A ❶ 188.00<br />
15 27.5 32 – BFK32 00A ❶ 220.00<br />
17 33 36 – BFK38 00A ❶ 256.00<br />
22 41 46 – 11 BF50K 00 ❶ 315.00<br />
26 50 56 – 11 BF65K 00 ❶ 385.00<br />
30 60 65 – 11 BF70K 00 ❶ 400.00<br />
34 65 70 – 11 BF80K 00 ❶ 430.00<br />
❶ Complete catalog number with coil digit per following table.<br />
AC coil digit Voltage range<br />
02460 24V 60Hz<br />
12060 120V 60Hz<br />
23060 200-240V 60Hz<br />
46060 440-480V 60Hz<br />
57560 575V 60Hz<br />
Other coil voltage and frequency values are available on request.<br />
❷ One normally open (NO) auxiliary contact incorporated.<br />
❸ Consult Sales & Technical Support for the use at contactors to switch with delta<br />
connection.<br />
Refer to page TC-13 for IEC ratings.<br />
Operational characteristics<br />
Type Rated Fuse<br />
current Sc/gG<br />
[A] [A]<br />
BFK09 12 16<br />
BFK12 16 25<br />
BFK20 22 40<br />
BFK26 26.5 40<br />
BFK32 36 63<br />
BFK38 40 63<br />
BF50K 58 80<br />
BF65K 68 100<br />
BF70K 72 125<br />
BF80K 78 125<br />
Ambient operating temperature: ≤120°F (50°C).<br />
For ambient temperatures higher than 50°C (120°F) and up<br />
to 160°F (70°C), the maximum operating power values<br />
indicated in the table must be reduced by a percentage<br />
equal to the difference between the operating ambient<br />
temperature and 120°F (50°C).<br />
E.g.: Using a BF25K 00 contactor at the ambient<br />
temperature of 140°F (60°C), the maximum operating<br />
power (at 400V) of the contactor will be equal to<br />
20 kvar – 10% = 18 kvar.<br />
Operating cycle: ≤120 cycles/h<br />
<strong>Electric</strong>al life: ≥200,000 cycles.<br />
Certifications and compliance<br />
UL listed for USA and Canada, file E93602.<br />
Compliant with standards:IEC/EN 60947-1,<br />
IEC/EN 60947-4-1.<br />
Kits to assemble<br />
BFK contactors<br />
For contactor Catalog number Price<br />
$ each<br />
BF09 10A - BF12 10A - BF18 10A 11 G460 49.00<br />
BF26 00A - BF32 00A<br />
BF38 00A<br />
BF50 00 - BF65 00 - BF80 00 11 G464 68.00<br />
To optimise contactor stock management, a kit is available<br />
to transform normal three-pole contactors into BF..K<br />
types for power factor correction. The table to the left<br />
indicates which kits to purchase depending on the standard<br />
contactor in stock.<br />
11 G460 - 11 G464<br />
Add-on blocks/Accessories<br />
page 3-14<br />
Spare parts<br />
pages 3-26, 27 and 30<br />
Dimensions<br />
page D-11<br />
Wiring diagrams<br />
page W-2<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com<br />
Technical characteristics<br />
pages TC-4 to 31
electric<br />
IEC style contactors<br />
Four-pole non-reversing contactors with operating coil in AC and DC<br />
3-9<br />
Special<br />
configurations of<br />
power poles<br />
(2NO+2NC and 4NC)<br />
11 BG09 T2 A<br />
UL Maximum current Power pole Catalog number Price<br />
Amp Inductive Resistive arrangement<br />
rating AC3 AC1<br />
[A] [A] [A] NO NC $ each<br />
AC COIL. With terminals: Clamp-screw.<br />
Mini-contactors.<br />
20 9 20 2 2 11 BG09 T2 A ❶ 71.00<br />
Contactors.<br />
25 9 25 2 2 BF09 T2A ❶ 90.00<br />
32 18 32 2 2 BF18 T2A ❶ 120.00<br />
45 26 45 2 2 BF26 T2A ❶ 175.00<br />
56 38 56 2 2 BF38 T2A ❶ 280.00<br />
32 18 32 0 4 BF18 T0A ❶ 120.00<br />
DC COIL. With terminals: Clamp-screw.<br />
Mini-contactors.<br />
20 9 20 2 2 11 BG09 T2 D ❷ 86.00<br />
Contactors.<br />
24 16 40 2 2 11 BF16C 22 ❷ 151.00<br />
40 25 40 2 2 11 BF25C 22 ❷ 212.00<br />
52 40 60 2 2 11 BF40C 22 ❷❸ 344.00<br />
24 16 40 0 4 11 BF16C 04 ❷ 151.00<br />
40 25 40 0 4 11 BF25C 04 ❷ 212.00<br />
3<br />
BF09 T2A<br />
❶ Complete catalog number with coil digit per following table.<br />
AC coil digit Voltage range<br />
02460 24V 60Hz<br />
12060 120V 60Hz<br />
23060 200-240V 60Hz<br />
46060 440-480V 60Hz<br />
57560 575V 60Hz<br />
Other coil voltage and frequency values are available on request.<br />
NOTE: No coil change or replacement is possible for BG contactor.<br />
❷ Complete the catalog number with coil digit.<br />
Standard voltages (coil digit) are: 024-110V.<br />
Other coil voltage values are available on request.<br />
NOTE: No coil change or replacement is possible for BG mini-contactors.<br />
❸ No side-mount auxiliary contacts can be added..<br />
Positively guided contacts<br />
See page 3-25 or TC-28 for add-on auxiliary contacts.<br />
Certifications and compliance<br />
UL listing for USA and Canada, file E93602.<br />
Compliant with standards: IEC/EN 60947-1,<br />
IEC/EN 60947-4-1.<br />
BF18 T0<br />
Add-on blocks/Accessories<br />
pages 3-12 to 20<br />
Spare parts<br />
pages 3-27, 28 and 30<br />
Dimensions<br />
pages D-4 to 6<br />
Wiring diagrams<br />
pages W-3 and 4<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com<br />
Technical characteristics<br />
pages TC-4 to 31
3-10<br />
IEC style contactors<br />
Control relays<br />
electric<br />
3<br />
Control relay<br />
BG type<br />
11 BG00<br />
11 BGF00<br />
Number Configuration Catalog number Price<br />
of contacts ❹<br />
NO NC $ each<br />
AC COIL. Terminals: clamp-screw.<br />
4 4 0 11 BG00 40 A❶ 45.00<br />
4 3 1 11 BG00 31 A❶ 45.00<br />
4 2 2 11 BG00 22 A❶ 45.00<br />
Terminals: Faston<br />
4 4 0 11 BGF00 40 A❶ 50.00<br />
4 3 1 11 BGF00 31 A❶ 50.00<br />
4 2 2 11 BGF00 22 A❶ 50.00<br />
DC COIL. Terminals: clamp-screw.<br />
4 4 0 11 BG00 40 D❷ 59.00<br />
4 3 1 11 BG00 31 D❷ 59.00<br />
4 2 2 11 BG00 22 D❷ 59.00<br />
Terminals: Faston<br />
4 4 0 11 BGF00 40 D❷ 65.00<br />
4 3 1 11 BGF00 31 D❷ 65.00<br />
4 2 2 11 BGF00 22 D❷ 65.00<br />
LOW-CONSUMPTION DC COIL. Terminals: clamp-screw.<br />
4 4 0 11 BG00 40 L❸ 72.00<br />
4 3 1 11 BG00 31 L❸ 72.00<br />
4 2 2 11 BG00 22 L❸ 72.00<br />
Terminals: Faston<br />
4 4 0 11 BGF00 40 L❸ 77.00<br />
4 3 1 11 BGF00 31 L❸ 77.00<br />
4 2 2 11 BGF00 22 L❸ 77.00<br />
Operational characteristics<br />
– Rated insulation voltage Ui 690V<br />
– Rated thermal current Ith 10A<br />
– UL designation: A600-Q600; see page TC-25 for details<br />
– Low-consumption version available.<br />
Positively guided contacts<br />
See page 3-24 or TC-27 for control relays with NC contacts.<br />
See page 3-25 or TC-28 for add-on auxiliary contacts.<br />
Certifications and compliance<br />
UL listed for USA and Canada, file E93602.<br />
Compliant with standards:IEC/EN 60947-1,<br />
IEC/EN 60947-5-1.<br />
❶ Complete catalog number with coil digit per following table.<br />
AC coil digit Voltage range<br />
02460 24V 60Hz<br />
12060 120V 60Hz<br />
23060 200-240V 60Hz<br />
46060 440-480V 60Hz<br />
57560 575V 60Hz<br />
Other coil voltage and frequency values are available on request.<br />
❷ Complete the catalog number with coil digit.<br />
Standard voltages (coil digit) are: 024-110V.<br />
Other coil voltage values are available on request.<br />
❸ Low-consumption version.<br />
No additional auxiliary contacts or the mechanical interlock BGX50 00 can be<br />
mounted.<br />
Complete the catalog number with coil digit.<br />
Standard voltages (coil digit) are: 024-048V.<br />
❹ Highly conductive contacts.<br />
NOTE: No coil change or replacement is possible.<br />
Add-on blocks/Accessories<br />
page 3-12 and 13<br />
Dimensions<br />
page D-4<br />
Wiring diagrams<br />
page W-3<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com<br />
Technical characteristics<br />
pages TC-4 to 27
electric<br />
IEC style contactors<br />
Control relays<br />
3-11<br />
Control relay<br />
BF type<br />
BF00A<br />
Number of Configuration Catalog number Price<br />
auxiliary ❷<br />
contacts<br />
NO NC $ each<br />
AC COIL<br />
Terminals: clamp-screw.<br />
4 4 0 BF00 40A ❶ 56.00<br />
4 3 1 BF00 31A ❶ 56.00<br />
4 2 2 BF00 22A ❶ 56.00<br />
4 0 4 BF00 04A ❶ 56.00<br />
❶ Complete catalog number with coil digit per following table.<br />
AC coil digit Voltage range<br />
02460 24V 60Hz<br />
12060 120V 60Hz<br />
23060 200-240V 60Hz<br />
46060 440-480V 60Hz<br />
57560 575V 60Hz<br />
Other coil voltage and frequency values are available on request.<br />
❷ Highly conductive contacts.<br />
Operational characteristics<br />
– Rated insulation voltage Ui 690V<br />
– Rated thermal current Ith 10A<br />
– UL designation: A600-P600; see page TC-25 for details.<br />
Positively guided contacts<br />
See page 3-24 or TC-27 for control relays with NC contacts.<br />
See page 3-25 or TC-28 for add-on auxiliary contacts.<br />
Certifications and compliance<br />
UL listed for USA and Canada, file E93602.<br />
Compliant with standards:IEC/EN 60947-1,<br />
IEC/EN 60947-5-1.<br />
3<br />
Add-on blocks/Accessories<br />
pages 3-18 to 20<br />
Spare parts<br />
page 3-28<br />
Dimensions<br />
page D-4<br />
Wiring diagrams<br />
page W-3<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com<br />
Technical characteristics<br />
pages TC-4 to 27
3-12<br />
IEC style contactors<br />
Add-on blocks and accessories for BG series mini-contactors<br />
electric<br />
3<br />
Add-on blocks<br />
11 BGX10... (20-11-02)<br />
11 BGX10... (40-31-22-13-04)<br />
11 BGXF...<br />
Accessories<br />
Characteristics Max Catalog number Price<br />
number<br />
per<br />
contactor<br />
n° $ each<br />
Auxiliary contacts with screw terminals.<br />
2NC 1 11 BGX10 02 13.80<br />
1NO + 1NC 1 11 BGX10 11 13.80<br />
2NO 1 11 BGX10 20 13.80<br />
4NC❷ 1 11 BGX10 04❷ 24.00<br />
1NO + 3NC❷ 1 11 BGX10 13❷ 24.00<br />
2NO + 2NC 1 11 BGX10 22 24.00<br />
3NO + 1NC 1 11 BGX10 31 24.00<br />
4NO 1 11 BGX10 40 24.00<br />
Auxiliary contacts with Faston terminals.<br />
2NC 1 11 BGXF10 02 16.00<br />
1NO + 1NC 1 11 BGXF10 11 16.00<br />
2NO 1 11 BGXF10 20 16.00<br />
4NC❷ 1 11 BGXF10 04❷ 27.00<br />
1NO + 3NC❷ 1 11 BGXF10 13❷ 27.00<br />
2NO + 2NC 1 11 BGXF10 22❷ 27.00<br />
3NO + 1NC 1 11 BGXF10 31 27.00<br />
4NO 1 11 BGXF10 40 27.00<br />
Mechanical interlock.<br />
All types 1 11 BGX50 00 12.00<br />
Quick connect surge suppressors.<br />
Varistor ≤48VAC/DC 11 BGX77 048 15.00<br />
48-125VAC/DC 11 BGX77 125 15.00<br />
125-240VAC/DC 11 BGX77 240 15.00<br />
Diode ≤225VDC 11 BGX78 225 15.00<br />
assembly<br />
RC-element ≤48VAC 11 BGX79 048 15.00<br />
(Resistor- 48-125VAC 11 BGX79 125 15.00<br />
condenser) 125-240VAC 11 BGX79 240 15.00<br />
Operational characteristics for add-on auxiliary contacts<br />
Type<br />
BGX<br />
Rated thermal current Ith A 10<br />
Rated insulation voltage Ui V 690<br />
Terminals Screw M 3<br />
Width mm 6.9 (0.2 in)<br />
Faston mm 1-6.3<br />
2-2.8<br />
Conductor section<br />
maximum with 1 or 2 wires<br />
flexible without lug mm 2 2.5<br />
flexible with lug mm 2 2.5<br />
AWG n° 14<br />
UL designation ❶ AC A600<br />
DC Q600<br />
Mechanical life (in millions) cycles 20<br />
Positively guided contacts<br />
See page 3-25 or TC-28 for blocks with both NO and NC<br />
auxiliary contacts.<br />
SM1 manual starter - mini-contactor connecting kits<br />
See page 1-5.<br />
Certifications and compliance<br />
BGX contacts, BGX50 00 interlock and all surge<br />
suppressors: UL listed for USA and Canada, file E93602<br />
SMX90 21 and SMX90 22:UL Recognized, file E197069.<br />
Auxiliary contacts comply with following standards:<br />
IEC/EN 60947-5-1; all others with IEC/EN 60947-1.<br />
11 BGX50 00<br />
11 BGX77 -<br />
11 BGX78 225 -<br />
11 BGX79<br />
240-415VAC 11 BGX79 415 15.00<br />
Modular cover❸.<br />
All types 1 11 BGX80 00 3.50<br />
Paralleling links. Clamp-screw terminals.<br />
For 2 poles 11 G323❹ 6.90<br />
11 G324 6.90<br />
For 4 poles 11 G325❹ 7.90<br />
11 G326 7.90<br />
Rigid connecting kits.<br />
Rigid connection kit for wye-delta 11 SMX90 21 21.00<br />
starter with combination<br />
of 3 BG mini-contactors<br />
Rigid connecting kit for reversing 11 SMX90 22 16.00<br />
contactor assembly with two<br />
BG contactors ❺❻<br />
11 SMX90 22<br />
❶ See page TC-25 for details.<br />
❷ Cannot be used with BG contactors with DC coil.<br />
❸ The cover can be used with BG types with screw termination only<br />
and with no auxiliary contacts, surge suppressor or mechanical<br />
interlock mounted.<br />
❹ Cannot be used with BGX80 00 cover.<br />
❺ Normally used with contactors having 1NC auxiliary contact<br />
(BG...01).<br />
❻ The RF9 relay cannot be directly mounted on the contactor. Use the<br />
RF38 or RF25 type and the RFX38 04 or G230 independent<br />
mounting base respectively.<br />
Dimensions<br />
page D-11<br />
Wiring diagrams<br />
page W-3<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com<br />
Technical characteristics<br />
pages TC-4 to 27
electric<br />
IEC style contactors<br />
Add-on blocks and accessories for BG series mini-contactors<br />
3-13<br />
Combinations<br />
Mounting position<br />
G325<br />
G326<br />
G323<br />
G324<br />
BGX77...<br />
BGX78 225<br />
BGX79...<br />
3<br />
BGX80 00❶<br />
BG...<br />
BGX10 40 - BGXF10 40<br />
BGX10 31 - BGXF10 31<br />
BGX10 22 - BGXF10 22<br />
BGX10 13 - BGXF10 13<br />
BGX10 04 - BGXF10 04<br />
BGX10 10 - BGXF10 10<br />
BGX10 11 - BGXF10 11<br />
BGX10 01 - BGXF10 01<br />
❶ Suitable for screw-termination contactors without BGX auxiliaries, BGX50 00 interlock or BGX7 surge suppressor.<br />
BGX77...<br />
BGX78 225<br />
BGX79...<br />
BG...<br />
BGX50 00<br />
BGX10 40 - BGXF10 40<br />
BGX10 31 - BGXF10 31<br />
BGX10 22 - BGXF10 22<br />
BGX10 13 - BGXF10 13<br />
BGX10 04 - BGXF10 04<br />
BGX10 40 - BGXF10 40<br />
BGX10 31 - BGXF10 31<br />
BGX10 22 - BGXF10 22<br />
BGX10 13 - BGXF10 13<br />
BGX10 04 - BGXF10 04<br />
BGX77...<br />
BGX78 225<br />
BGX79...<br />
BGX10 10 - BGXF10 10<br />
BGX10 11 - BGXF10 11<br />
BGX10 02 - BGXF10 02<br />
BGX10 10 - BGXF10 10<br />
BGX10 11 - BGXF10 11<br />
BGX10 02 - BGXF10 02<br />
Connections for reversing contactor<br />
assembly<br />
Connections for wye-delta assembly<br />
SMX90 22<br />
SMX90 21<br />
BGX50 00<br />
BG<br />
BG<br />
SMX90 21<br />
SMX90 22<br />
Dimensions<br />
page D-11<br />
Wiring diagrams<br />
page W-3<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com<br />
Technical characteristics<br />
pages TC-3 to 27
3-14<br />
IEC style contactors<br />
Add-on blocks and accessories for BF series contactors<br />
electric<br />
3<br />
Add-on blocks<br />
BFX10 (02-11-20)<br />
11 G484<br />
(03-12-21-30)<br />
BFX10<br />
(04-13-22-31-40)<br />
11 G418<br />
11 G481<br />
11 G482<br />
11 G485 - 11 G486<br />
11 G487<br />
11 G218<br />
11 G428 (01-01D-10-10A)<br />
Characteristics Maximum Catalog Price<br />
number per number<br />
contactor<br />
$ each<br />
Instantaneous auxiliary contacts with front center mounting.<br />
Screw terminals.<br />
2NC 1 BFX10 02 ❶ 14.00<br />
1NO + 1NC 1 BFX10 11 ❶ 14.00<br />
2NO 1 BFX10 20 ❶ 14.00<br />
4NC 1 BFX10 04 ❷ 28.00<br />
1NO + 3NC 1 BFX10 13 ❷ 28.00<br />
2NO + 2NC 1 BFX10 22 ❷ 28.00<br />
3NO + 1NC 1 BFX10 31 ❷ 28.00<br />
4NO 1 BFX10 40 ❷ 28.00<br />
3NC 1 11 G484 03 ❶ 22.00<br />
1NO + 2NC 1 11 G484 12 ❶ 22.00<br />
2NO + 1 NC 1 11 G484 21 ❶ 22.00<br />
3NO 1 11 G484 30 ❶ 22.00<br />
Instantaneous auxiliary contacts with front lateral mounting.<br />
Screw terminals.<br />
1NO 2 11 G418 10 13.20<br />
1EM early make 2 11 G418 10A 13.20<br />
1NC 2 11 G418 01 13.20<br />
1LB late break 2 11 G418 01D 13.20<br />
Faston terminals.<br />
1NO or 1NC reversible 2 11 G218 12.20<br />
2NO 2 11 G481 20 16.50<br />
1NO + 1NC 2 11 G481 11 16.50<br />
2NC 2 11 G481 02 16.50<br />
Double-throw❸ 2 11 G482❹ 30.80<br />
Side mount adapters.<br />
For G218 2 11 G280 3.50<br />
For G481 and G482 2 11 G483 4.60<br />
Auxiliary contacts for side mounting, duly fitted on side-mount<br />
adapter. Screw terminals.<br />
1NC 2 11 G428 01 17.40<br />
1LB late break 2 11 G428 01D 17.40<br />
1NO 2 11 G428 10 17.40<br />
1EM early make 2 11 G428 10E 17.40<br />
Delayed auxiliary contacts 1NO + 1NC (pneumatic operation)<br />
on energization ❶. Screw terminals.<br />
3 seconds 1 11 G485 3 112.00<br />
6 seconds 1 11 G485 6 112.00<br />
15 seconds 1 11 G485 15 112.00<br />
30 seconds 1 11 G485 30 112.00<br />
60 seconds 1 11 G485 60 112.00<br />
120 seconds 1 11 G485 120 112.00<br />
Delayed auxiliary contacts 1NO + 1NC (pneumatic operation)<br />
on de-energization ❶. Screw terminals.<br />
3 seconds 1 11 G486 3 112.00<br />
6 seconds 1 11 G486 6 112.00<br />
15 seconds 1 11 G486 15 112.00<br />
30 seconds 1 11 G486 30 112.00<br />
60 seconds 1 11 G486 60 112.00<br />
120 seconds 1 11 G486 120 112.00<br />
70 milliseconds 1 11 G487 112.00<br />
Operational characteristics for add-on auxiliary contacts<br />
Type G418 BFX10 G218 G482❻<br />
G428 G484 G481<br />
G485❺<br />
G486❺<br />
G487❺<br />
Rated current Ith A 10 10 10 0.1❼<br />
Rated insulation V 690 690 690 690<br />
voltage Ui<br />
Terminals: Screw M 3.5 M 3 –– ––<br />
Width mm 7 6.9 –– ––<br />
(0.2in) (0.2in)<br />
Faston mm –– –– 1-6.35 1-6.35<br />
2-2.8 2-2.8<br />
Conductor section<br />
maximum with 1<br />
or 2 wires<br />
flexible w/o lug mm 2 2.5 2.5 –– ––<br />
flexible c/w lug mm 2 2.5 2.5 2.5 2.5<br />
AWG n° 14 14 14 14<br />
Terminal protection IP20❽ IP20 IP20❿ IP20❿<br />
according to<br />
IEC/EN 60529<br />
UL AC A600 A600 A600 ––<br />
designation❹ DC P600❾ Q600 P600 ––<br />
Mechanical life cycles 10 11 10 10 10<br />
(in millions)<br />
❹ See page TC-25 for details.<br />
❺ For particularly severe ambient conditions, contact Sales & Technical<br />
Support.<br />
❻ Gold-plated contacts inside tight enclosure for use in pollutant<br />
environments.<br />
❼ Referred to 125VAC and 30VDC.<br />
❽ Finger safe IP20 protection is warranted to equipment wired with<br />
0.75mm 2 /18 AWG minimum conductor section for G418 or G428<br />
and 1mm 2 /18 AWG minimum for G480, G485, G486 and G487<br />
types.<br />
❾ Q600 for G418...<br />
❿ Finger safe IP20 protection is warranted to equipment wired with<br />
insulated Faston terminals.<br />
11 3 million cycles for G485, G486, G487.<br />
Positively guided contacts<br />
See page 3-21 or TC-21 for blocks with both NO and NC<br />
auxiliary contacts.<br />
SM1 manual starter - contactor connecting kits<br />
See page 1-5.<br />
Certifications and compliance<br />
BFX contacts: UL Listed for USA and Canada, file<br />
E93601; pending for BFX10 04, BFX10 13, BFX10 22,<br />
BFX10 31, BFX10 40.<br />
All others: UL Recognized for USA, file E93601 and CSA<br />
certified, file LR 54332-15.<br />
Compliant with standards: IEC/EN 60947-1,<br />
IEC/EN 60947-5-1.<br />
Maximum assembly combination of add-on blocks<br />
See page TC-28.<br />
❶ Highly conductive contacts. The contacts can<br />
also be fitted on B type contactors using the<br />
adapter G358. See pages 3-24 and 3-25.<br />
❷ Available during 2007; contact Sales & Technical<br />
Support for details.<br />
❸ Highly conductive contact.<br />
Dimensions<br />
page D-11 and 12<br />
Wiring diagrams<br />
pages W-3 and 4<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com<br />
Technical characteristics<br />
pages TC-4 to 29
electric<br />
IEC style contactors<br />
Add-on blocks and accessories for BF series contactors<br />
3-15<br />
Add-on blocks and<br />
accessories<br />
BFX42<br />
BFX50 00 BFX50 01<br />
BFX50 02<br />
11 G223<br />
11 G222<br />
11 G272<br />
BFX50 03<br />
11 G269 1<br />
11 G269 2<br />
Characteristics Maximum Catalog Price<br />
number per number<br />
contactor<br />
$ each<br />
Fourth pole.<br />
For BF26A-BF32A 1 BFX42 72.00<br />
and BF38A<br />
Mechanical interlock.<br />
Side mount for 1 BFX50 00 ❶ 25.00<br />
BF00A, BF09A-BF38A<br />
Side mount with 2NC 1 BFX50 01 ❶ 36.00<br />
contacts for BF00A,<br />
BF09A-BF38A<br />
Front mount low profile for 1 BFX50 02 10.00<br />
BF00A, BF09A-BF38A<br />
Front mount for 1 BFX50 03 30.00<br />
BF00A, BF09A-BF38A<br />
Front mount for BF9C-BF40C 1 11 G223 8.00<br />
(BF40C three-pole only) 1 11 G269 1 24.00<br />
Front mount for BF40C 40, 1 11 G269 2 24.00<br />
BF50-BF110<br />
Mechanical latch.<br />
For BF00A, 1 11 G222 ❷ 74.00<br />
BF09A-BF38A,<br />
BF9C-BF40C (BF40C<br />
three-pole type only)<br />
For BF40C four pole, 11 G272 ❷ 74.00<br />
BF50-BF110<br />
Quick-connect surge suppressors for BF...A contactors,<br />
top mount.<br />
Varistor ≤48VAC BFX77 048 17.00<br />
48-125VAC BFX77 125 17.00<br />
125-240VAC BFX77 240 17.00<br />
Resistor- ≤48VAC BFX79 048 21.00<br />
Condenser 48-125VAC BFX79 125 21.00<br />
125-240VAC BFX79 240 21.00<br />
240-415VAC BFX79 415 21.00<br />
Surge suppressors for BC...C or BF50-B110 contactors,<br />
front mount, Faston terminals.<br />
Varistor ≤48VAC 11 G318 48 22.00<br />
48-125VAC 11 G318 125 22.00<br />
125-240VAC 11 G318 240 22.00<br />
240-415VAC/DC 11 G315 415 22.00<br />
Diode ≤225VDC 11 G319 225 22.00<br />
RC-element ≤48VAC 11 G319 225 22.00<br />
(resistor- 48-240VAC 11 G322 220 22.00<br />
condenser)<br />
240-415VAC 11 G322 380 22.00<br />
Suppressor holder.<br />
For 35 mm DIN rail (IEC/EN 60715) 11 RE244 4.00<br />
Operational characteristics for mechanical latch<br />
Type BFX42 BFX50 01<br />
Conventinal free air A 55 10<br />
thermal Current Ith<br />
Rated insulation<br />
voltage Ui V 690 690<br />
Terminals: Screw M4 M3<br />
Width mm 12.5 7<br />
Conductor section<br />
Maximum with<br />
1 or 2 cables<br />
flexible w/o lug mm 2 16 2.5<br />
flexible c/w lug mm 2 16 2.5<br />
AWG n° 6 14<br />
Terminal protection IP20❸ IP20<br />
per IEC/EN60529<br />
UL designation ❹ AC –– A600<br />
DC –– Q600<br />
Mechanical life (in millions) cycles 10 10<br />
Type G222 G272<br />
Control circuit<br />
voltage AC (50/60 Hz) V 12-380 12-380<br />
DC V 12-220 12-220<br />
Power consumption<br />
with control AC VA 40 40<br />
DC W 70 70<br />
Minimum energising<br />
drop-out ms 10 10<br />
pick-up ms 50 100<br />
❸ See pages CT-18 to 20 to warrant finger-safe IP20 protection.<br />
❹ See page TC-25 for details.<br />
Maximum assembly combination of add-on blocks<br />
See page TC-28.<br />
Certifications and compliance<br />
BFX42 fourth pole, BFX50 interlocks, BFX77 and BFX79<br />
suppressors: UL listings for USA and Canada, pending<br />
completion.<br />
G223 and G269 interlocks, G222 and G272 latches: UL<br />
Recognized for USA, file E93601 and CSA certified for<br />
Canada, file LR 54332-15.<br />
Compliant with standards: IEC/EN 60947-1,<br />
IEC/EN 60947-5-1.<br />
3<br />
❶ Different sized contactors can be interlocked.<br />
Example: BF09A-BF25A with BF26A-BF38A.<br />
❷ Complete catalog number with voltage digit per following table.<br />
BFX77<br />
BFX79<br />
Voltage digit Voltage range<br />
AC type<br />
50/60Hz<br />
024 24V<br />
110 110/125V<br />
220 200/240V<br />
DC type<br />
DC<br />
C024<br />
24V<br />
C110 110/125V<br />
C220<br />
220V<br />
Other coil voltage and frequency values are available on request.<br />
11 G318<br />
11 G319 225<br />
11 G322<br />
11 RE244<br />
Dimensions<br />
pages D-11 and 12<br />
Wiring diagrams<br />
pages W-3 and 4<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com<br />
Technical characteristics<br />
pages TC-4 to 27
3-16<br />
IEC style contactors<br />
Add-on blocks and accessories for BF series contactors<br />
electric<br />
3<br />
Accessories<br />
BFX31...<br />
BFX32...<br />
BFX 80<br />
Characteristics Catalog Price<br />
number<br />
$ each<br />
Rigid connecting kits for three-pole reversing contactor<br />
assembly.<br />
For contactors BFX31 01❶ 24.00<br />
BF09A - BF25A side by side<br />
For contactors BFX32 01❷ 58.00<br />
BF26A - BF38A side by side<br />
Rigid connecting kits for wye-delta starters.<br />
For contactors BF09A-BF25A BFX31 31 36.00<br />
(line-wye-delta)<br />
For contactors BF26A-BF38A BFX32 31 64.00<br />
(line-wye-delta)<br />
For contactors BF26A-BF38A BFX32 32 64.00<br />
(line-delta) and<br />
BF09A-BF25A (wye)<br />
Sealing cover.<br />
For contactors BFX80 5.00<br />
BF00A, BF09A-BF38A<br />
Screw fixing adapters for contactors.<br />
Universal base to screw fix BFX89 01 4.00<br />
BF09A-BF38A contactors<br />
Screw fixing brackets for BFX89 02 3.00<br />
BF09A-BF38A contactors<br />
❶ Mechanical interlock BFX50 02 or BFX50 03 can be used only.<br />
❷ Any type of BFX50 mechanical interlock can be used.<br />
Certifications and compliance<br />
BFX31 and BFX32 rigid kits: UL Recognized for USA and<br />
Canada, pending completion.<br />
Compliant with standards: IEC/EN 60947-1.<br />
BFX89 01<br />
BFX89 02<br />
Dimensions<br />
page D-12<br />
Wiring diagrams<br />
page W-4<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com<br />
Technical characteristics<br />
pages TC-4 to 28
electric<br />
IEC style contactors<br />
Add-on blocks and accessories for BF series contactors<br />
3-17<br />
Accessories<br />
Characteristics Catalog Price<br />
number<br />
$ each<br />
Power terminal cover ❶.<br />
11 G265<br />
11 BA135<br />
11 BA235<br />
11 G231<br />
11 G232<br />
11 BA435<br />
11 G285<br />
Finger safe IP20 protection for 3-pole 11 G265 6.50<br />
BF50-BF110<br />
Paralleling links.<br />
2-pole configuration (BF09A-BF25A and 11 BA135 3.00<br />
BF9-BF16)<br />
2-pole configuration (BF26A-BF38A and 11 BA235 4.00<br />
BF20-BF40)<br />
3-pole configuration (BF50-BF110) 11 BA435 6,70<br />
Enlarged terminals, single pole.<br />
1-6 mm 2 /10 AWG for BF09-BF25A and 11 G231 5.50<br />
BF9-BF16)<br />
1-10 mm 2 /8 AWG for BF26A-BF38A and 11 G232 6.50<br />
BF20-BF25)<br />
Enlarged terminals, three poles.<br />
1-35 mm 2 /3 AWG for BF32-BF40 11 G281 25.00<br />
1-50 mm 2 /1/0 AWG for BF50-BF110 11 G271 35.00<br />
Enlarged terminals, four poles.<br />
1-50 mm 2 /1/0 AWG for BF50-BF110 11 G288 65.00<br />
Auxiliary terminal.<br />
For BF50-BF95 11 G285 6.50<br />
Marking element for BF00A, BF09A-B110 contactors<br />
Blank label for writing BFX30 2.00<br />
Marking element for BF...C and BF50-BF110 contactors.<br />
Blank label for writing 11 BA126 2 1.00<br />
3<br />
11 G281<br />
❶ For 3-pole contactors, BF50-BF110 types only.<br />
NOTE: Two pieces are required per contactor.<br />
11 G271<br />
G288<br />
11 BA126 2<br />
Dimensions<br />
pagesD-12<br />
Technical characteristics<br />
pages TC-4 to 28<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com
3-18<br />
IEC style contactors<br />
Add-on blocks and accessories for BF series contactors<br />
electric<br />
Combinations<br />
Mounting position on BF contactors<br />
without mechanical latch mounted<br />
3<br />
BFX10<br />
G485<br />
G486<br />
G487<br />
G222❷<br />
G272<br />
G484<br />
BFX10<br />
G418<br />
BFX77<br />
BFX79<br />
(for contactors<br />
BF...A)<br />
BFX50 00<br />
BFX50 01<br />
(for contactors BF00A, BF09A-BF38A only)<br />
BF<br />
G218<br />
G481<br />
G482<br />
G419❶<br />
G280❶<br />
❶<br />
G318<br />
G319<br />
G322<br />
BFX50 02<br />
(for contactors BF00A, BF09A-BF38A)<br />
G223<br />
(for contactors BF9C-BF40C)<br />
G418❶<br />
G483❶<br />
G428...❶<br />
BFX50 03<br />
(for contactors BF00A, BF09A-BF38A)<br />
G269 1<br />
(for contactors BF9C-BF40C)<br />
G218❶<br />
G481❶<br />
G482❶<br />
G269 2<br />
(for contactors BF40C 40, BF50-BF110)<br />
❶ Mounting not possible if front lateral contacts or mechanical interlock BFX50 00 or BFX50 01 are mounted.<br />
❷ If the G222 latch is mounted, no front lateral contacts can be fitted.<br />
Dimensions<br />
page D-12 and 13<br />
Wiring diagrams<br />
page W-3 and 4<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com
electric<br />
IEC style contactors<br />
Add-on blocks and accessories for BF series contactors<br />
3-19<br />
Combinations<br />
Mounting position on BF contactors<br />
with mechanical latch G222 mounted.<br />
Control relay<br />
BF00A<br />
Contactors<br />
BF09A-BF38A<br />
BF9C-BF40C<br />
G484<br />
BFX10<br />
G48<br />
G486<br />
G487<br />
3<br />
BFX10<br />
BF00A<br />
BF09A-BF38A<br />
BF9C-BF40C<br />
BFX77<br />
BFX79<br />
(for contactors<br />
BF...A)<br />
G222<br />
Combinations<br />
Mounting position on BF contactors<br />
with mechanical latch G272 mounted.<br />
Contactors<br />
BF50-BF110<br />
BF40C 40<br />
BF40C 22<br />
BFX10<br />
G484<br />
BFX10<br />
G485<br />
G486<br />
G487<br />
BF50-BF110<br />
BF40C 40<br />
BF40C 22❷<br />
G418<br />
G419❶<br />
G280❶<br />
❶<br />
G272<br />
G218<br />
G481<br />
G482<br />
G318<br />
G319<br />
G322<br />
G483❶<br />
G418<br />
G428❶<br />
G269 2<br />
G218<br />
G481<br />
G482<br />
❶ Mounting not possible if front lateral contacts are mounted.<br />
❷ No side-mount contacts can be fitted on BF40C 22.<br />
Dimensions<br />
page D-12 and 13<br />
Wiring diagrams<br />
pages W-3 and 4<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com<br />
Technical characteristics<br />
pages TC-4 to 28
3-20<br />
IEC style contactors<br />
Add-on blocks and accessories for BF series contactors<br />
electric<br />
Combinations<br />
Accessories<br />
Wire<br />
6-50mm 2 /<br />
1/0AWG<br />
Plate<br />
2.5x9mm (max)<br />
0.1x0.35in (max)<br />
3<br />
G271<br />
BA435<br />
G265<br />
G285<br />
BF50-BF110 contactors<br />
G281<br />
G232<br />
BA235<br />
G231<br />
BA135<br />
BF50-BF110<br />
BF32C - BF40C<br />
BF00A<br />
BF09A-BF25A<br />
BF9C-BF16C<br />
BF26A-BF38A<br />
BF20C - BF25C<br />
BA126 2<br />
(except BF...A types)<br />
BFX80<br />
(for contactors BF...A)<br />
Dimensions<br />
page D-12<br />
Wiring diagrams<br />
pages W-3 and 4<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com<br />
Technical characteristics<br />
pages TC-4 to 28
electric<br />
IEC style contactors<br />
Add-on blocks and accessories for BF series contactors<br />
3-21<br />
Rigid reversing contactor assembly connecting kits for BF09A-BF25A types<br />
Rigid reversing contactor assembly connecting kits for BF26A-BF38A types<br />
BFX50 02<br />
BFX31 01<br />
BFX50 02<br />
BFX32 01<br />
BFX50 02<br />
BFX50 02<br />
BFX50 03<br />
3<br />
BFX50 03<br />
BFX31 01<br />
RF38<br />
BFX32 01<br />
RF38<br />
BFX50 00<br />
BFX50 01<br />
RF38 thermal overload relay can be mounted only on left side contactor.<br />
Rigid wye-delta starter connecting kits for BF09A-BF25A types<br />
RF38 thermal overload relay can be mounted only on left side contactor.<br />
Rigid wye-delta starter connecting kits for BF26A-BF38A types<br />
BFX31 31<br />
BFX32 31<br />
BFX31 31<br />
RF38<br />
RF38<br />
BFX32 31<br />
Rigid wye-delta starter connecting kits with BF26A-BF38A (line-delta) and BF09A-BF25A (wye) contactors<br />
BFX32 32<br />
BFX32 32<br />
RF38<br />
Dimensions<br />
pages D-12 and 13<br />
Wiring diagrams<br />
page W-4<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com<br />
Technical characteristics<br />
pages TC-4 to 28
3-22<br />
IEC style contactors<br />
Add-on blocks and accessories for B series contactors<br />
electric<br />
3<br />
Add-on blocks and<br />
accessories<br />
11 G350 - 11 G354<br />
11 G358<br />
11 G360 - 11 G361 - 11 G363<br />
11 G527 - 11 G528<br />
11 G529 - 11 G530<br />
11 G370<br />
Characteristics Max. number Catalog Price<br />
per<br />
number<br />
contactor<br />
Instantaneous auxiliary contacts.<br />
$ each<br />
2NO+1NC or 1NO+2NC 4❶ 11 G350❶ 42.00<br />
reversible<br />
1NO+1NC 4❶ 11 G354❶ 34.00<br />
Contact block adapter.<br />
To fit auxiliary contacts 4 11 G358 25.00<br />
BFX10 with 2 contacts,<br />
G484, G485, G486 and<br />
G487 types, on<br />
B115-B630 contactors;<br />
see page 3-14.<br />
Mechanical interlocks.<br />
Side by side 11 G355❷ 47.00<br />
One on top of other 11 G356 1❷ 96.00<br />
One on top of other 11 G356 2❷ 96.00<br />
One on top of other 11 G356 3❷ 96.00<br />
One on top of other 11 G356 4❷ 96.00<br />
One on top of other 11 G356 5❷ 96.00<br />
One on top of other 11 G356 6❷❸ 96.00<br />
Power terminal covers.<br />
For contactor B115 11 G360❹ 12.00<br />
For contactors B145-B180 11 G361❹ 15.00<br />
For contactors B250-B310-B400 11 G363❹ 28.00<br />
For contactors B500 11 G527 122.00<br />
For contactors B500 4 11 G528 139.00<br />
For contactors B630 11 G529 127.00<br />
For contactors B630 4 11 G530 144.00<br />
3 pole wye connecting bars.<br />
For B115-B145-B180 11 BA1595 18.00<br />
For B250-B310-B400 11 BA1721 22.00<br />
For B500-B630 11 BA1846 28.00<br />
2 pole bars for parallel configuration.<br />
For B115-B145-B180 11 BA1594 24.00<br />
For B250-B310-B400 11 BA1720 38.00<br />
For B500-B630 11 BA1845 54.00<br />
Terminal adapters.<br />
To individually transform 11 G370 4.00<br />
Faston terminals of auxiliary<br />
contacts and coils into screw<br />
terminals<br />
To transform both coil Faston 11 G371 14.00<br />
terminals into screw terminals<br />
Marking element.<br />
Label for writing 11 BA126 2 1.00<br />
❶ Only one piece can be mounted on B1250 or B1600 type.<br />
❷ For choice and allowed distances see page TC-30. One piece must be used to<br />
interlock two contactors of B115-B630 type.<br />
❸ Two pieces are needed to interlock B1250 or B1600 type.<br />
❹ Provided for one pole terminal only. Example: For three-pole contactors, purchase<br />
3 pieces for the upper terminals only or 6 pieces for all upper and lower terminals.<br />
Operational characteristics of auxiliary contacts<br />
Type<br />
G350<br />
G354<br />
Rated thermal current Ith A 16<br />
Rated insulation voltage Ui V 690<br />
Terminals Faston 1-6.35<br />
2-2.8<br />
Max cross section connectable<br />
with 1 or 2 conductors<br />
flexible c/w lug mm 2 2.5<br />
AWG n° 14<br />
UL designation ❺ AC A600<br />
DC P600<br />
Mechanical life (in millions) cycles 5<br />
❺ See page TC-25 for details.<br />
Positively guided contacts<br />
See page 3-21 or TC-21 for blocks with both NO and NC<br />
auxiliary contacts.<br />
Maximum assembly combination<br />
See pages TC-27 to TC-28.<br />
Certifications and compliance<br />
G350 and G354 contacts, all interlocks, G360-G361-G363<br />
power terminal covers: UL Recognized for USA, file<br />
E93601; CSA certified for Canada, file LR 54332-15.<br />
G270 adapter:CSA certfified for Canada, file LR 54332-15.<br />
Add-on auxiliary contacts comply with the following<br />
standards: IEC/EN 60947-1, IEC/EN 60947-5-1.<br />
11 G371<br />
Dimensions<br />
pages D-13 and 14<br />
Wiring diagrams<br />
page W-4<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com<br />
Technical characteristics<br />
pages TC-24 to 31
F<br />
E<br />
G<br />
D<br />
C<br />
A<br />
B<br />
electric<br />
IEC style contactors<br />
Add-on blocks and accessories for B series contactors<br />
3-23<br />
Combination<br />
Mounting position<br />
G527 (per B500 00)<br />
G528 (per B500 4 00)<br />
G529 (per B630 00)<br />
G530 (per B630 4 00)<br />
3<br />
G370<br />
G356...<br />
G371<br />
G363 (per B310-B400)<br />
G355<br />
G350<br />
G354<br />
M 8<br />
G360 (per B115)<br />
G361 (per B145-B180)<br />
M 6<br />
BA1846<br />
B500<br />
B630<br />
BA1845<br />
BA1720<br />
B250<br />
B310<br />
B400<br />
BA1721<br />
BA1595<br />
BA1594<br />
BA126 2<br />
BFX10<br />
B115<br />
B145<br />
B180<br />
G484<br />
G485<br />
G486<br />
G487<br />
G371<br />
G358<br />
G358<br />
G358<br />
G358<br />
NB. Also refer to combinations given on page TC-29.<br />
Dimensions<br />
pages D-13 and 14<br />
Wiring diagrams<br />
pages W-3 and 4<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com<br />
Technical characteristics<br />
pages TC-24 to 31
3-24<br />
IEC style contactors<br />
Positively guided contacts<br />
electric<br />
3<br />
Positively guided<br />
contacts for types<br />
with incorporated<br />
auxiliary contacts<br />
Positively guided contacts are a requirement in safety circuits<br />
to correctly monitor the status of normally open contacts.<br />
Guided contacts imply that Normally Open (NO) and Normally<br />
Closed (NC) will operate together reciprocally but can never be<br />
simultaneously closed, even in case of NO contacts weld. This<br />
requirement is obtained by particular constructional details,<br />
such as reduced gap tolerance through which the mobile<br />
contact travels and the points of actuation are closer to the<br />
actual contact position.<br />
Positively Guided Contacts are also called positively safety<br />
contacts, forced contacts, linked contacts, force or positive<br />
guided or positively driven contacts.<br />
The positively guided contacts assume different meanings and<br />
terminologies in compliance with the product standards which<br />
are given below.<br />
IEC 60947-4-1/A1 ed. 2 - Annex F<br />
In this case, positively guided contacts are called auxiliary<br />
contacts linked with power contacts (mirror contact).<br />
The requirement is that when power poles weld, the auxiliary<br />
NC contacts remain open.<br />
This requirement is standard supplied on all our contactors<br />
having an integrated NC auxiliary contacts:<br />
BG..01, BF09 01A, BF12 01A, BF18 01A, BF25 01A, BF9C..01,<br />
BF12C..01, BF16C..01, BF20C..01 or BF25C..01 types.<br />
PHYSICAL PROPERTIES OF MIRROR CONTACT<br />
MIRROR CONTACT<br />
CONVENTIONAL<br />
NC CONTACT<br />
DE-ENERGIZED<br />
NC<br />
mirror contact<br />
NO<br />
power contacts<br />
NC NO<br />
contact power contacts<br />
(monitoring)<br />
ENERGIZED<br />
NC<br />
mirror contact<br />
(monitoring)<br />
NO<br />
power contacts<br />
NC NO<br />
contact power contacts<br />
(monitoring)<br />
DE-ENERGIZED<br />
WELD<br />
WELD<br />
NC<br />
mirror contact<br />
(monitoring)<br />
WILL<br />
REMAIN<br />
OPEN<br />
NO<br />
power contacts<br />
NC<br />
contact<br />
(monitoring)<br />
WILL<br />
CLOSE<br />
NO<br />
power contacts<br />
IEC 60947-5-1/A2 ed. 2 - Annex L<br />
In this case, positively guided contacts are called<br />
mechanically linked contacts.<br />
The requirement is that NO and NC contacts can never be<br />
simultaneously closed, even if the NO contact or NC contact<br />
welds in closed position.<br />
This requirement applies to auxiliary safety contacts included<br />
in control circuit devices where the actuating positively is<br />
provided internally; therefore, this does not apply to push<br />
buttons or limit switches.<br />
Lovato control relays, such as BG00 and BF00, which have at<br />
least one NO and one NC contact, fall into this category.<br />
(See Physical properties of mechanically linked contacts on<br />
page 3-29).<br />
Note:<br />
Control circuit devices, operated externally (e.g. push-button or limit-switches) can not have mechanically linked contact elements.<br />
Such devices, in safety applications, generally have contacts with Direct Opening Actuation.<br />
Add-on blocks/Accessories<br />
pages 3-12 to 22<br />
Spare parts<br />
pages 3-26 to 30<br />
Dimensions<br />
pages D-4 and 5<br />
Wiring diagrams<br />
pages W-2 to 4<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com<br />
Technical characteristics<br />
pages TC-3 to 31
electric<br />
IEC style contactors<br />
Positively guided contacts<br />
3-25<br />
Positively guided<br />
contacts for add-on<br />
auxiliary contact<br />
blocks<br />
IEC 60947-5-1/A2 ed. 2 - Annex L<br />
In this case, positively guided contacts are called mechanically<br />
linked contacts.<br />
The requirement is that NO and NC contacts can never be<br />
simultaneously closed, even if the NO contact or NC contact<br />
welds in closed position.<br />
This requirement applies to auxiliary safety contacts included<br />
in control circuit devices where the actuating positively is<br />
provided internally; therefore, this does not apply to push<br />
PHYSICAL PROPERTIES OF MECHANICAL LINKED CONTACTS<br />
buttons or limit switches.<br />
Several auxiliary contact blocks, which have at least one NO<br />
and one NC contact, fall into this category. These blocks<br />
include:<br />
BGX10 11, BGX10 31, BGX10 22, BGX10 13, BFX10 02,<br />
BFX10 11, BFX10 13, BFX10 22, BFX10 31, BGXF10 11,<br />
BGXF10 31, BGXF10 22, BGXF10 13, G350, G354, G481 11,<br />
G484 12 and G484 21.<br />
3<br />
MECHANICALLY<br />
LINKED CONTACT<br />
CONVENTIONAL CONTACT<br />
DE-ENERGIZED<br />
NC<br />
contacts<br />
(monitoring)<br />
NO<br />
contacts<br />
NC<br />
contacts<br />
(monitoring)<br />
NO<br />
contacts<br />
ENERGIZED<br />
NC<br />
contacts<br />
(monitoring)<br />
NO<br />
contacts<br />
NC<br />
contacts<br />
(monitoring)<br />
NO<br />
contacts<br />
DE-ENERGIZED<br />
WELD<br />
WELD<br />
NC<br />
contacts<br />
(monitoring)<br />
WILL<br />
REMAIN<br />
OPEN<br />
NC<br />
contacts<br />
(monitoring)<br />
WILL<br />
CLOSE<br />
NO<br />
contacts<br />
Add-on blocks/Accessories<br />
pages 3-12 to 22<br />
Spare parts<br />
pages 3-26 to 31<br />
Dimensions<br />
pages D-11 to 13<br />
Wiring diagrams<br />
pages W-3 and 4<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com<br />
Technical characteristics<br />
pages TC-3 to 31
3-26<br />
IEC style contactors<br />
Spare parts<br />
electric<br />
3<br />
AC coils for<br />
contactors BF00A<br />
and BF09A-BF25A<br />
(standard voltages)<br />
Rated Catalog number Price<br />
frequency<br />
and voltage<br />
[Hz] [V] $ each<br />
For contactors BF00A-BF09A-BF12A-BF18A-BF25A<br />
60 24 BFX91A 024 60❶ 27.00<br />
120 BFX91A 120 60❶ 27.00<br />
230 BFX91A 230 60❶ 27.00<br />
460 BFX91A 460 60❶ 27.00<br />
575 BFX91A 575 60❶ 27.00<br />
❶ Four-terminal coil.<br />
Operational characteristics<br />
AC control<br />
Rated voltage from V 12<br />
at 60Hz to V 600<br />
Operating limits from % Us 80<br />
pick up<br />
to % Us 110<br />
drop out<br />
from % Us 20<br />
to % Us 55<br />
Consumption<br />
in-rush VA 70<br />
60Hz<br />
holding VA 6.5<br />
Dissipation W 2.5<br />
Materials<br />
Class F enamelled copper wire.<br />
11 BFX91A..<br />
Special versions<br />
For coils with non standard voltages, contact Sales &<br />
Technical Support.<br />
AC coils for<br />
contactors BF26A,<br />
BF32A and BF38A<br />
(standard voltages)<br />
Rated Catalog number Price<br />
frequency<br />
and voltage<br />
[Hz] [V] $ each<br />
For contactors BF26A-BF32A-BF38A.<br />
60 24 BFX92A 024 60❶ 33.00<br />
120 BFX92A 120 60❶ 33.00<br />
230 BFX92A 230 60❶ 33.00<br />
460 BFX92A 460 60❶ 33.00<br />
575 BFX92A 575 60❶ 33.00<br />
❶ Four-terminal coil.<br />
Operational characteristics<br />
AC control<br />
Rated voltage from V 12<br />
at 60Hz: to V 600<br />
Operating limits from % Us 80<br />
pick up<br />
to % Us 110<br />
drop out<br />
from % Us 20<br />
to % Us 55<br />
Consumption<br />
in-rush VA 70<br />
60Hz<br />
holding VA 6.5<br />
Dissipation W 2.5<br />
Materials<br />
Class F enamelled copper wire.<br />
Special versions<br />
For coils with non standard voltages, contact Sales &<br />
Technical Support.<br />
11 BFX92A<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com
electric<br />
IEC style contactors<br />
Spare parts<br />
3-27<br />
AC coils for BF<br />
contactors<br />
(standard voltages)<br />
11 BA705<br />
Rated Catalog number Price<br />
frequency<br />
and voltage<br />
[Hz] [V] $ each<br />
For contactors BF50 to BF110.<br />
60 24 11 BA705 024 60 46.00<br />
120 11 BA705 120 60 46.00<br />
200-240 11 BA705 230 60 46.00<br />
440-480 11 BA705 460 60 46.00<br />
575 11 BA705 575 60 46.00<br />
NOTE. Other coil voltage and frequency values are available on request.<br />
Contact Sales & Technical Support.<br />
Operational characteristics<br />
AC control<br />
Rated voltage at 60Hz: V 12 - 600<br />
Operating limits pick up % Us 80 - 110<br />
at 60Hz drop out % Us 40 - 55<br />
Consumption<br />
in-rush VA 252<br />
60Hz<br />
holding VA 21.6<br />
Dissipation W 6<br />
Materials<br />
Class F enamelled copper wire.<br />
3<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com
3-28<br />
IEC style contactors<br />
Spare parts<br />
electric<br />
3<br />
DC coils for BF…C<br />
contactors<br />
(standard voltages)<br />
Rated Catalog number Price<br />
voltage<br />
[V]<br />
$ each<br />
For BF9C-BF12C-BF16C-BF20C-BF25C-BF32C-BF40C contactors.<br />
24 11 BA904 024 49.00<br />
110 11 BA904 110 49.00<br />
NOTE. Other coil voltage values are available on request.<br />
Contact Sales & Technical Support.<br />
Operational characteristics<br />
DC control<br />
Rated voltage V 12 - 660<br />
Operating limits pick-up % Us 80 - 110<br />
drop-out % Us 10 - 25<br />
Average consumption W 9<br />
Materials<br />
Class F enamelled copper wire.<br />
11 BA904<br />
Rated Catalog number Price<br />
voltage<br />
[V]<br />
$ each<br />
For BF40C 40-BF50C-BF65C-BF80C-BF95C-BF110C contactors.<br />
24 11 BA911 024 74.00<br />
110 11 BA911 110 74.00<br />
NOTE. Other coil voltage values are available on request.<br />
Contact Sales & Technical Support.<br />
Operational characteristics<br />
DC control<br />
Rated voltage V 12 - 660<br />
Operating limits pick-up % Us 80 - 110<br />
drop-out % Us 10 - 25<br />
Average consumption W 15<br />
Materials<br />
Class F enamelled copper wire.<br />
11 BA911<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com
electric<br />
IEC style contactors<br />
Spare parts<br />
3-29<br />
Coils for<br />
B115-B630<br />
contactors<br />
Bridge rectifier<br />
Coil protection<br />
Coil assembly<br />
For contactor Catalog number Price<br />
§ each<br />
Bridge rectifier (Faston terminals).<br />
B115-B145-B180 11 BA1575 1 81.00<br />
B250-B310-B400 11 BA1700 1 95.00<br />
B500-B630-B630 1000 11 BA1799 172.00<br />
B1250-B1600<br />
Coil protection.<br />
B115-B145-B180 11 BA1553 25.00<br />
B250-B310-B400 11 BA1678 45.00<br />
B500-B630-B630 1000 11 BA1803 97.00<br />
B1250-B1600<br />
Coil assembly (Coil, rectifier and coil protection).<br />
B115-B145-B180 11 BA1546 ❶ 234.00<br />
B250-B310-B400 11 BA1671 ❶ 378.00<br />
B500-B630-B630 1000 11 BA1796 ❷ 670.00<br />
B1250-B1600<br />
❶ Complete catalog number with coil digit per following table.<br />
Coil digit<br />
Voltage range<br />
AC/DC<br />
024 24V<br />
110 110/125V<br />
220 220/240V<br />
460 440/480V<br />
Other coil voltage values are available on request.<br />
❷ Complete catalog number with coil digit per following table.<br />
Coil digit<br />
Voltage range<br />
AC/DC<br />
110 110/125V<br />
220 220/240V<br />
460 440/480V<br />
Other coil voltage values are available on request.<br />
Operational characteristics<br />
AC and DC control<br />
For contactor type<br />
B115 - B145 - B180<br />
Supply voltage<br />
AC and DC<br />
Rated control voltage V 24-480<br />
Operating limits pick-up % Us 80-110<br />
drop-out % Us 30-60<br />
Consumption in-rush VA/W 300<br />
holding VA/W 10<br />
Dissipation W 10<br />
For contactor type<br />
B250 - B310 - B400<br />
Supply voltage<br />
AC and DC<br />
Rated control voltage V 24-480<br />
Operating limits pick-up % Us 80-110<br />
drop-out % Us 30-60<br />
Consumption in-rush VA/W 300<br />
holding VA/W 10<br />
Dissipation W 10<br />
For contactor type<br />
B500 - B630<br />
B630 1000<br />
Supply voltage<br />
AC and DC<br />
Rated control voltage V 48-480<br />
Operating limits pick-up % Us 80-110<br />
drop-out % Us 30-60<br />
Consumption in-rush VA/W 400<br />
holding VA/W 18<br />
Dissipation W 18<br />
3<br />
AC control<br />
For contactor type<br />
B1250 - B1600<br />
Supply voltage<br />
in AC<br />
Rated control voltage V 110-240-480<br />
Operating limits pick-up % Us 80-110<br />
drop-out % Us 30-60<br />
Consumption in-rush VA/W 800<br />
holding VA/W 45<br />
Dissipation W 40<br />
Operating limits for ambient temperatures up to<br />
105°F (40°C) are 0.8 to 1.1 times rated voltage.<br />
NOTE: For use at ambient temperatures exceeding 130°F<br />
(55°C), contact Sales & Technical Support.<br />
Materials<br />
Class F enamelled copper wire.<br />
Coil assembly<br />
Comprises the coil, bridge rectifier, fixed magnetic core, coil<br />
protection, cross piece and fixing screws.<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com
3-30<br />
IEC style contactors<br />
Spare parts<br />
electric<br />
3<br />
Main contacts and<br />
arc chutes<br />
11 G234 - 11 G235 - 11 G236<br />
11 G237 - 11 G470<br />
11 G273 - 11 G279<br />
11 G274 - 11 G275<br />
11 G276 - 11 G475<br />
For contactor Catalog number Price<br />
$ each<br />
Main contacts❶.<br />
3 or 4 pole set complete with screws.<br />
BF9C 11 G234 18.00<br />
BF9C 40 11 G234 4 24.00<br />
BF12C 11 G235 22.00<br />
BF16C 11 G470 26.00<br />
BF16C 40 11 G470 4 34.00<br />
BF20C 11 G236 31.00<br />
BF20C 40 11 G236 4 41.00<br />
BF25C 11 G237 35.00<br />
BF25C 40 11 G237 4 46.00<br />
BF26A BFX99 026T 46.00<br />
BF26A T4A BFX99 026F 61.00<br />
BF32A BFX99 032T 84.00<br />
BF32C 11 G273 63.00<br />
BF38A BFX99 038T 113.00<br />
BF38 T4A BFX99 038F 150.00<br />
BF40C 11 G279 85.00<br />
BF40C 40 11 G279 4 113.00<br />
BF50 11 G274 122.00<br />
BF50 40 11 G274 4 161.00<br />
BF65 11 G275 155.00<br />
BF65 40 11 G275 4 206.00<br />
BF80 11 G276 192.00<br />
BF80 40 11 G276 4 254.00<br />
BF95 11 G475 241.00<br />
BF110 11 G476 297.00<br />
Special versions<br />
For non standard spare contact configurations, contact<br />
Sales & Technical Support.<br />
❶ Proper selection requires date code of contactor. Contact Sales & Technical<br />
Support for assistance.<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com
electric<br />
IEC style contactors<br />
Spare parts<br />
3-31<br />
Main contacts and<br />
arc chutes<br />
11 G380 - 11 G381 - 11 G382<br />
11 G383 - 11 G384 - 11 G385<br />
11 G525 - 11 G526<br />
Arc chute<br />
For contactor Catalog number Price<br />
$ each<br />
Main contacts.<br />
3 or 4 pole set complete with Allen screws and key for<br />
contact replacement.<br />
B115 11 G380 226.00<br />
B115 4 11 G380 4 278.00<br />
B145 11 G381 330.00<br />
B145 4 11 G381 4 395.00<br />
B180 11 G382 356.00<br />
B180 4 11 G382 4 466.00<br />
B250 11 G383 598.00<br />
B250 4 11 G383 4 808.00<br />
B310 11 G385 728.00<br />
B310 4 11 G385 4 998.00<br />
B400 11 G384 911.00<br />
B400 4 11 G384 4 1231.00<br />
B500 11 G525 1414.00<br />
B500 4 11 G525 4 2206.00<br />
B630 11 G526 2376.00<br />
B630 4 11 G526 4 3141.00<br />
B630 1000 11 G537 2727.00<br />
B630 1000 4 11 G537 4 3510.00<br />
B1250 11 G538 2877.00<br />
B1250 4 11 G538 4 3839.00<br />
B1600 11 G539 4752.00<br />
B1600 4 11 G539 4 6338.00<br />
Arc chutes.<br />
B115-B145-B180 11 BA1588 96.00<br />
B115 4-B145 4-B180 4 11 BA1589 126.00<br />
B250-B310-B400 11 BA1713 268.00<br />
B250 4-B310 4-B400 4 11 BA1714 308.00<br />
B500-B630 11 BA1838 349.00<br />
B630 1000<br />
B500 4-B630 4 11 BA1839 572.00<br />
B630 1000 4<br />
Special versions<br />
For non standard spare contact configurations, contact<br />
Sales & Technical Support.<br />
For B1250 and B1600 contactor spares, contact Sales &<br />
Technical Support for details.<br />
3<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com
THREE-POLE DP CONTACTORS<br />
• Up to 50A motor FLA<br />
• Up to 55A resistive loads<br />
• Low coil consumption.<br />
PAGE 4-2<br />
FOUR-POLE DP CONTACTORS<br />
• Up to 50A motor FLA<br />
• Up to 55A resistive loads<br />
• Low coil consumption.<br />
PAGE 4-2<br />
ACCESSORIES<br />
• Auxiliary contacts blocks<br />
• Surge suppressors<br />
• Mechanical interlocks<br />
• Fourth pole.<br />
PAGE 4-3<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com
4<br />
DEFINITE PURPOSE CONTACTORS<br />
Ideal contactors for air<br />
conditioning, heating,<br />
refrigeration, ventilation<br />
Wide range coils +10% to -20%<br />
Finger safe terminals<br />
Four-pole versions available<br />
Extensive assortment of add-on<br />
blocks and accessories<br />
Compact design<br />
PLANET -SWITCH<br />
SEC. PAGE<br />
Definite purpose contactors<br />
Three-pole . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4- 2<br />
Four-pole . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4- 2<br />
Add-on blocks and accessories<br />
For DPBG types . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4- 3<br />
For DPBF...A types . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4- 4<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com
4-2<br />
Definite purpose contactors<br />
Three-pole and four-pole non-reversing DP contactors 600VAC<br />
®<br />
electric<br />
MINI-CONTACTORS<br />
CONTACTORS<br />
4<br />
DPBG12<br />
DPBF09 T4<br />
DPBF12 T4<br />
DPBF09A<br />
DPBF12A<br />
DPBF18A<br />
DPBF26A<br />
DPBF26 T4<br />
DPBF32A<br />
Motor Locked Rotor Resistive Maximum Horsepower Incorporated Type of Catalog Number Price<br />
Full auxiliary termination<br />
Load 1 Phase 3 Phase contacts<br />
600V 240V 480V 600V 600V 120V 240V 200V 240V 480V 600V<br />
[A] [A] [A] [A] [A] [HP] [HP] [HP] [HP] [HP] [HP] NO NC $ each<br />
THREE POWER POLES<br />
14 84 84 84 20 3<br />
/4 2 3 3 10 10 0 1 Clamp-screw DPBG12 01 A❶ 76.00<br />
1 0 DPBG12 10 A❶ 76.00<br />
20 120 120 100 30 1 1 /2 3 5 5 10 10 0 1 Clamp-screw DPBF09 01 A❶ 81.00<br />
1 0 DPBF09 10 A❶ 81.00<br />
25 150 150 125 30 2 3 5 5 10 15 0 1 Clamp-screw DPBF12 01 A❶ 102.00<br />
1 0 DPBF12 10 A❶ 102.00<br />
30 180 180 150 32 2 5 7 1 /2 7 1 /2 15 20 0 1 Clamp-screw DPBF18 01 A❶ 117.00<br />
1 0 DPBF18 10 A❶ 117.00<br />
40 240 240 200 50 3 7 1 /2 10 10 30 30 0 0 Clamp-screw DPBF26 00 A❶ 150.00<br />
50 300 300 250 55 3 10 15 15 30 40 0 0 Clamp-screw DPBF32 00 A❶ 154.00<br />
FOUR POWER POLES ❷<br />
14 84 84 84 20 3<br />
/4 2 3 3 10 10 0 0 Clamp-screw DPBG12 T4 A❶ 79.00<br />
20 120 120 100 30 1 1 /2 3 5 5 10 10 0 0 Clamp-screw DPBF09 T4 A❶ 90.00<br />
25 150 150 125 30 2 3 5 5 10 15 0 0 Clamp-screw DPBF12 T4 A❶ 111.00<br />
30 180 180 150 32 2 5 7 1 /2 7 1 /2 15 20 0 0 Clamp-screw DPBF18 T4 A❶ 142.00<br />
40 240 240 200 50 3 7 1 /2 10 10 30 30 0 0 Clamp-screw DPBF26 T4 A❶ 162.00<br />
❶ Complete catalog number with coil code as follow:<br />
Code<br />
Voltage range<br />
024 60 24VAC 60Hz<br />
120 60 120VAC 60Hz<br />
230 60 230VAC 60Hz<br />
460 60 460VAC 60Hz<br />
575 60 575VAC 60Hz<br />
Complete starter can be assembled using overload relays<br />
indicated in Section 5.<br />
❷ The DPBF32A 3-pole type can be retrofitted with fourth pole, catalog<br />
number BFX42. Refer to page 4-5.<br />
Positively guided contacts<br />
See page TC-26 for details.<br />
Certifications and compliance<br />
UL listed for USA and Canada, file E93602.<br />
Compliant with standards: UL508.<br />
Add-on blocks/Accessories<br />
page 4-3 to 5<br />
Dimensions<br />
page D-4<br />
Wiring diagrams<br />
pags W-2 and 3<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com<br />
Technical characteristics<br />
pages TC-4 to 28
®<br />
electric<br />
Definite purpose contactors<br />
Add-on blocks and accessories for DPBG12 contactors<br />
4-3<br />
11 BGX10 11<br />
11 BGX11 11<br />
11 BGX10 31<br />
11 BGX77<br />
11 BGX78 225<br />
11 BGX79<br />
Characteristics Maximum Catalog Price<br />
qty per number<br />
contactor<br />
$ each<br />
Auxiliary contacts with screw terminals.<br />
2NC 1 11 BGX10 02 13.80<br />
1NO + 1NC 1 11 BGX10 11 13.80<br />
2NO 1 11 BGX10 20 13.80<br />
4NC ❶ 1 11 BGX10 04❶ 24.00<br />
1NO + 3NC ❶ 1 11 BGX10 13❶ 24.00<br />
2NO + 2NC 1 11 BGX10 22 24.00<br />
3NO + 1NC 1 11 BGX10 31 24.00<br />
4NO 1 11 BGX10 40 24.00<br />
Mechanical interlock.<br />
For both DPBG types 1 11 BGX50 00 12.00<br />
Quick connect surge suppressors (Faston terminals).<br />
≤48VAC/DC (Varistor) 11 BGX77 048 15.00<br />
48-125VAC/DC (Varistor) 11 BGX77 125 15.00<br />
125-240VAC/DC (Varistor) 11 BGX77 240 15.00<br />
≤225VDC (Diode) 11 BGX78 225 15.00<br />
≤48VAC (Resistor-Capacitor) 11 BGX79 048 15.00<br />
48-125VAC (Resistor-Capacitor) 11 BGX79 125 15.00<br />
125-240VAC (Resistor-Capacitor) 11 BGX79 240 15.00<br />
240-415VAC (Resistor-Capacitor) 11 BGX79 415 15.00<br />
Modular cover ❷.<br />
For both DPBG types 1 11 BGX80 00 3.50<br />
❶ Connot be used with DPBG with DC coil.<br />
❷ Connot be fitted if other accessories are mounted.<br />
Operational characteristics for add-on auxiliary contacts<br />
Type<br />
BGX10...<br />
BGX11...<br />
Rated conventional free air A 10<br />
thermal current Ith<br />
Rated insulation voltage Ui V 690<br />
voltage Ui<br />
Terminals Screw M3<br />
Width mm 6.9<br />
Conductor section<br />
maximum with 1 or 2 cables<br />
flexible without lug mm 2 2.5<br />
flexible with lug mm 2 2.5<br />
AWG n° 14<br />
UL designation ❸ AC A600<br />
DC Q600<br />
Mechanical life cycles 20<br />
(in millions)<br />
❸ See page TC-25 for details.<br />
Positively guided contacts<br />
See page TC-27 with both NO and NC auxiliary contacts.<br />
Certifications and compliance<br />
UL listed for USA and Canada file E93602 for auxiliary<br />
contacts.<br />
Compliant with standards: IEC/EN 60947-1,<br />
IEC/EN 60947-5-1.<br />
4<br />
11 BGX50 00<br />
Dimensions<br />
page D-11<br />
Wiring diagrams<br />
page W-3<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com<br />
Technical characteristics<br />
pages TC-25 to 27
4-4<br />
Definite purpose contactors<br />
Add-on blocks and accessories for DPBF series contactors<br />
®<br />
electric<br />
4<br />
Add-on blocks<br />
BFX10 (02-11-20)<br />
11 G484<br />
(03-12-21-30)<br />
BFX10<br />
(04-13-22-31-40)<br />
11 G418<br />
11 G481<br />
11 G482<br />
11 G218<br />
11 G428... (01-01D-10-10A)<br />
Characteristics Maximum Catalog Price<br />
number per number<br />
contactor<br />
$ each<br />
Instantaneous auxiliary contacts with front center mounting.<br />
Screw terminals.<br />
2NC 1 BFX10 02 ❶ 14.00<br />
1NO + 1NC 1 BFX10 11 ❶ 14.00<br />
2NO 1 BFX10 20 ❶ 14.00<br />
4NC 1 BFX10 04 ❶❷ 28.20<br />
1NO + 3NC 1 BFX10 13 ❶❷ 28.20<br />
2NO + 2NC 1 BFX10 22 ❶❷ 28.20<br />
3NO + 1NC 1 BFX10 31 ❶❷ 28.20<br />
4NO 1 BFX10 40 ❶❷ 28.20<br />
3NC 1 11 G484 03 ❶ 22.00<br />
1NO + 2NC 1 11 G484 12 ❶ 22.00<br />
2NO + 1 NC 1 11 G484 21 ❶ 22.00<br />
3NO 1 11 G484 30 ❶ 22.00<br />
Instantaneous auxiliary contacts with front lateral mounting.<br />
Screw terminals.<br />
1NO 2 11 G418 10 12.00<br />
1EM early make 2 11 G418 10A 12.00<br />
1NC 2 11 G418 01 12.00<br />
1LB late break 2 11 G418 01D 12.00<br />
Faston terminals.<br />
1NO or 1NC reversible 2 11 G218 11.00<br />
2NO 2 11 G481 20 15.00<br />
1NO + 1NC 2 11 G481 11 15.00<br />
2NC 2 11 G481 02 15.00<br />
Double-throw❸ 2 11 G482❸ 28.00<br />
Side mount adapters.<br />
For G218 2 11 G280 3.20<br />
For G481 and G482 2 11 G483 4.20<br />
Auxiliary contacts for side mounting, duly fitted on side-mount<br />
adapter. Screw terminals.<br />
1NC 2 11 G428 01 17.40<br />
1LB late break 2 11 G428 01D 17.40<br />
1NO 2 11 G428 10 17.40<br />
1EM early make 2 11 G428 10E 17.40<br />
Delayed auxiliary contacts 1NO + 1NC (pneumatic operation)<br />
on energization ❶. Screw terminals.<br />
3 seconds 1 11 G485 3 102.00<br />
6 seconds 1 11 G485 6 102.00<br />
15 seconds 1 11 G485 15 102.00<br />
30 seconds 1 11 G485 30 102.00<br />
60 seconds 1 11 G485 60 102.00<br />
120 seconds 1 11 G485 120 102.00<br />
Delayed auxiliary contacts 1NO + 1NC (pneumatic operation)<br />
on de-energization ❶. Screw terminals.<br />
3 seconds 1 11 G486 3 102.00<br />
6 seconds 1 11 G486 6 102.00<br />
15 seconds 1 11 G486 15 102.00<br />
30 seconds 1 11 G486 30 102.00<br />
60 seconds 1 11 G486 60 102.00<br />
120 seconds 1 11 G486 120 102.00<br />
70 milliseconds 1 11 G487 102.00<br />
Operational characteristics for add-on auxiliary contacts<br />
Type G418 BFX10 G218 G482❻<br />
G428 G484 G481<br />
G485❺<br />
G486❺<br />
G487❺<br />
Rated current Ith A 10 10 10 0.1❼<br />
Rated insulation V 690 690 690 690<br />
voltage Ui<br />
Terminals: Screw M 3.5 M 3 –– ––<br />
Width mm 7 6.9 –– ––<br />
(0.2in) (0.2in)<br />
Faston mm –– –– 1-6.35 1-6.35<br />
2-2.8 2-2.8<br />
Conductor section<br />
maximum with 1<br />
or 2 wires<br />
flexible w/o lug mm 2 2.5 2.5 –– ––<br />
flexible c/w lug mm 2 2.5 2.5 2.5 2.5<br />
AWG n° 14 14 14 14<br />
Terminal protection IP20❽ IP20 IP20❿ IP20❿<br />
according to<br />
IEC/EN 60529<br />
UL AC A600 A600 A600 ––<br />
designation❹ DC P600❾ Q600 P600 ––<br />
Mechanical life cycles 10 11 10 10 10<br />
(in millions)<br />
❹ See TC-25 for details.<br />
❺ For particularly severe ambient conditions, contact Sales & Technical<br />
Support.<br />
❻ Gold-plated contacts inside tight enclosure for use in pollutant environments.<br />
❼ Referred to 125VAC and 30VDC.<br />
❽ Finger safe IP20 protection is warranted to equipment wired with<br />
0.75mm 2 /18 AWG minimum conductor section for G418 or G428<br />
and 1mm 2 /18 AWG minimum for G480, G485, G486 and G487<br />
types.<br />
❾ Q600 for G418.<br />
❿ Finger safe IP20 protection is warranted to equipment wired with<br />
11 insulated Faston terminals.<br />
12 3 million cycles for G485, G486, G487.<br />
Positively guided contacts<br />
See page TC-27 for blocks with both NO and NC auxiliary<br />
contacts.<br />
Certifications and compliance<br />
BFX contacts: UL Listed for USA and Canada, file<br />
E93601; pending for BFX10 04, BFX10 13, BFX10 22,<br />
BFX10 31, BFX10 40.<br />
All others: UL Recognized for USA, file E93601 and CSA<br />
certified, file LR 54332-15.<br />
Compliant with standards: IEC/EN 60947-1,<br />
IEC/EN 60947-5-1.<br />
Maximum assembly combination of add-on blocks<br />
See page TC-28.<br />
11 G485 - 11 G486<br />
11 G487<br />
❶ Highly conductive contacts.<br />
❷ Available during 2007; contact Sales & Technical Support for availability.<br />
❸ Highly conductive contact.<br />
Add-on blocks/Accessories<br />
page 4-3 to 5<br />
Dimensions<br />
page D-12<br />
Wiring diagrams<br />
pages W-3 and 4<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com<br />
Technical characteristics<br />
pages TC-25 to 28
®<br />
electric<br />
Definite purpose contactors<br />
Add-on blocks and accessories for DPBF series contactors<br />
4-5<br />
Add-on blocks and<br />
accessories<br />
BFX42<br />
BFX50 00 BFX50 01<br />
Characteristics Maximum Catalog Price<br />
number per number<br />
contactor<br />
$ each<br />
Fourth pole<br />
For DPBF26A and 1 BFX42 72.00<br />
DPBF32A<br />
Mechanical interlock for all DPBF types.<br />
Side mount 1 BFX50 00 ❶ 25.00<br />
Side mount with 2NC 1 BFX50 01 ❶ 36.00<br />
contacts<br />
Front mount 1 BFX50 02 10.00<br />
low profile<br />
Front mount 1 BFX50 03 30.00<br />
Quick-connect surge suppressors top mount for all DPBF types.<br />
Varistor ≤48VAC BFX77 048 17.00<br />
48-125VAC BFX77 125 17.00<br />
125-240VAC BFX77 240 17.00<br />
Resistor- ≤48VAC BFX79 048 21.00<br />
Condenser 48-125VAC BFX79 125 21.00<br />
125-240VAC BFX79 240 21.00<br />
240-415VAC BFX79 415 21.00<br />
Sealing cover.<br />
For DPBF contactors BFX80 5.00<br />
Screw fixing adapters.<br />
Universal base to screw fix DPBF contactors BFX89 01 4.00<br />
Screw fixing brackets for DPBF contactors BFX89 02 3.00<br />
Marking element for all DPBF contactors.<br />
Blank label for writing BFX30 2.00<br />
Operational characteristics for mechanical latch<br />
Type BFX42 BFX50 01<br />
Conventinal free air A 55 10<br />
thermal Current Ith<br />
Rated insulation<br />
voltage Ui V 690 690<br />
Terminals: Screw M4 M3<br />
Width mm 12.5 7<br />
Conductor section<br />
Maximum with<br />
1 or 2 cables<br />
flexible w/o lug mm 2 16 2.5<br />
flexible c/w lug mm 2 16 2.5<br />
AWG n° 6 14<br />
Terminal protection IP20❷ IP20<br />
per IEC/EN60529<br />
UL designation ❸ AC A600 ––<br />
DC –– Q600<br />
Mechanical life (in millions) cycles 10 10<br />
Type G222 G272<br />
Control circuit<br />
voltage AC (50/60 Hz) V 12-380 12-380<br />
DC V 12-220 12-220<br />
Power consumption<br />
with control AC VA 40 40<br />
DC W 70 70<br />
Minimum energising<br />
drop-out ms 10 10<br />
pick-up ms 50 100<br />
4<br />
❶ Different sized contactors can be interlocked.<br />
Example: DPBF09A-DPBF18A with DPBF26A-BF38A.<br />
❷ See pages TC-18 and 19 to warrant finger-safe IP20 protection.<br />
❸ See page TC-25 for details.<br />
BFX50 02 BFX50 03<br />
Maximum assembly combination of add-on blocks<br />
See page TC-28.<br />
Certifications and compliance<br />
UL listing for USA and Canada, pending completion.<br />
Compliant with standards: IEC 60947-1, IEC/EN 60947-5-1.<br />
BFX77<br />
BFX79<br />
BFX 80<br />
BFX89 01<br />
BFX89 02<br />
Dimensions<br />
page D-12<br />
Wiring diagrams<br />
pages W-3 and 4<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com<br />
Technical characteristics<br />
pages TC-25 to 28
PAGE 5-2<br />
FOR BG SERIES MINI-CONTACTORS<br />
• Type RF9, single phase sensitive, three poles,<br />
manual reset<br />
• Type RFA9, single phase sensitive, three poles,<br />
automatic reset<br />
• Type RFS9, single phase sensitive, two poles,<br />
manual reset<br />
• Type RFSA9, single phase sensitive, two poles,<br />
automatic reset.<br />
PAGE 5-4<br />
FOR BF SERIES CONTACTORS<br />
• Type RF38, single phase sensitive, three poles,<br />
manual or automatic reset<br />
• Types RF25 and RF95, single phase sensitive,<br />
three poles, manual reset<br />
• Types RFA25 and RFA95, single phase sensitive,<br />
three poles, automatic reset<br />
• Types RFS25 and RFS95, single phase sensitive,<br />
two poles, manual reset<br />
• Types RFSA25 and RFSA95, single phase<br />
sensitive, two poles, automatic reset.<br />
PAGE 5-8<br />
FOR B SERIES CONTACTORS<br />
• Type RF200 and RF420, single phase sensitive,<br />
three poles, manual or automatic reset.<br />
RF38 features<br />
FRONT PROTECTION COVER OF<br />
THERMAL OVERLOAD RELAYS<br />
A sealable protection cover is<br />
available. When fitted on to the<br />
relay front, it precludes all<br />
possible adjuster tampering and<br />
involuntary activation of the<br />
“Reset” and “Stop” buttons of the<br />
thermal overload relay.<br />
CLEAR IDENTIFICATION OF THERMAL OVERLOAD<br />
RELAY MANUAL OR AUTOMATIC RESET<br />
The RF38 thermal<br />
overload relay is supplied<br />
configured for manual<br />
resetting. By breaking<br />
the two tabs, the “Reset”<br />
button can be rotated to automatic resetting.<br />
The broken tabs and the index indicator provides<br />
for immediate and distinct identification of the<br />
selected configuration.<br />
FIXING EASE OF THE THERMAL<br />
OVERLOAD RELAY<br />
While the thermal overload<br />
relay is being linked to the<br />
contactor, its auxiliary contact<br />
fits on and connects to the coil<br />
terminal by rigid terminal.<br />
Complete relay fixing is done in<br />
a single operation, without the<br />
need of other connections.<br />
SEALABLE RELAY COVER<br />
A handy closing flap<br />
feature excludes any<br />
tampering with the thermal<br />
overload relay adjuster.<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com
5<br />
IEC STYLE OVERLOAD RELAYS<br />
IEC style adjustable bimetallic<br />
overload relays<br />
Class 10A thermal overload relays<br />
for motor currents 0.14 to 630A<br />
Ambient compensated<br />
Three phase (3-pole) and single<br />
phase (2-pole) types<br />
Three phase units are single phase<br />
sensitive for better motor<br />
protection<br />
Automatic and/or manual reset<br />
Direct mount to contactor or<br />
separate mount<br />
PLANET -SWITCH<br />
SEC. PAGE<br />
IEC style overload relays<br />
With BG series mini-contactors<br />
For three-phase starters, RF9 and RFA9 types . . . . . . . . . . . . . . . . . . . . . . . . . . . 5- 2<br />
For single-phase starters, RFS9 and RFSA9 types . . . . . . . . . . . . . . . . . . . . . . . . 5- 3<br />
With BF series contactors<br />
For three-phase starters, RF38 - RF25 - RF95 - RFA25 - RFA95 types . . . . . . . . 5- 4<br />
For single-phase starters, RFS38 - RFS25 - RFSA25 - RFSA95 types . . . . . . . . 5- 6<br />
With B series contactors<br />
For three-phase starters, RF200 and RF420 types . . . . . . . . . . . . . . . . . . . . . . . . 5- 8<br />
Accessories for all versions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5- 9<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com
5-2<br />
IEC style overload relays<br />
For three-phase starters with BG series mini-contactors<br />
electric<br />
5<br />
Three poles, single<br />
phase sensitive<br />
(three phase)<br />
11 RF9<br />
11 RFA9<br />
Adjustment Catalog number Price<br />
range<br />
[A]<br />
$ each<br />
MANUAL RESET.<br />
For direct mounting on BG06-BG09 and BG12 mini-contactors ❶.<br />
0.14 - 0.23 11 RF9 023 55.00<br />
0.2 - 0.33 11 RF9 033 55.00<br />
0.3 - 0.5 11 RF9 05 55.00<br />
0.45 - 0.75 11 RF9 075 55.00<br />
0.6 - 1 11 RF9 1 55.00<br />
0.9 - 1.5 11 RF9 1V5 55.00<br />
1.4 - 2.3 11 RF9 2V3 55.00<br />
2 - 3.3 11 RF9 33 55.00<br />
3 - 5 11 RF9 5 55.00<br />
4.5 - 7.5 11 RF9 75 55.00<br />
6 - 10 11 RF9 10 55.00<br />
9 - 15 11 RF9 15 55.00<br />
AUTOMATIC RESET.<br />
For direct mounting on BG06-BG09 and BG12 mini-contactors ❶.<br />
0.14 - 0.23 11 RFA9 023 60.00<br />
0.2 - 0.33 11 RFA9 033 60.00<br />
0.3 - 0.5 11 RFA9 05 60.00<br />
0.45 - 0.75 11 RFA9 075 60.00<br />
0.6 - 1 11 RFA9 1 60.00<br />
0.9 - 1.5 11 RFA9 1V5 60.00<br />
1.4 - 2.3 11 RFA9 2V3 60.00<br />
2 - 3.3 11 RFA9 33 60.00<br />
3 - 5 11 RFA9 5 60.00<br />
4.5 - 7.5 11 RFA9 75 60.00<br />
6 - 10 11 RFA9 10 60.00<br />
9 - 15 11 RFA9 15 60.00<br />
Operational characteristics<br />
– Tripping class: 10A<br />
– Normal operating limits: -4...+130°F (-20...+55°C);<br />
compensation from 5°F (-15°C)<br />
– Storage temperature: -65...+160°F (-55...+70°C)<br />
– Maximum altitude: 9800ft (3000m)<br />
– Mounting position: normally on vertical plane,<br />
±30° admissible<br />
– Fixed to contactor<br />
– Includes: test button and trip indicator<br />
– Auxiliary contacts: 1NO + 1NC.<br />
Version without single-phase sensitivity is available on<br />
request. Contact Sales & Technical Support for the relative<br />
catalog numbers and pricing.<br />
The appropriate adjustment range of the overload relay<br />
should be selected on the basis of the motor nameplate<br />
full-load current when across the line starting is considered.<br />
NOTE: To facilitate connection between the auxiliary NC<br />
contact of the thermal relay RF9 or RFA9 and terminal A2 of<br />
the contactor, insert the wire lead into the appropriate<br />
conduit as shown.<br />
Certification and compliance<br />
UL listed, for USA and Canada, file E93601.<br />
CSA certified, file LR 054332_0_000, class 3211-03.<br />
Compliant with standards: IEC/EN 60947-1, IEC/EN 60947-4-1.<br />
❶ Suitable for definite-purpose contactor DPBG12.<br />
Accessories<br />
page 5-9<br />
Dimensions<br />
page D-4<br />
Wiring diagrams<br />
page W-5<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com<br />
Technical characteristics<br />
pages TC-32 and 33
electric<br />
IEC style overload relays<br />
For single-phase starters with BG series mini-contactors<br />
5-3<br />
Two poles<br />
(single phase)<br />
11 RFS9<br />
Adjustment Catalog number Price<br />
range<br />
[A]<br />
$ each<br />
MANUAL RESET.<br />
Direct mounting on BG06-BG09 and BG12 mini-contactors ❶.<br />
0.14 - 0.23 11 RFS9 023 50.00<br />
0.2 - 0.33 11 RFS9 033 50.00<br />
0.3 - 0.5 11 RFS9 05 50.00<br />
0.45 - 0.75 11 RFS9 075 50.00<br />
0.6 - 1 11 RFS9 1 50.00<br />
0.9 - 1.5 11 RFS9 1V5 50.00<br />
1.4 - 2.3 11 RFS9 2V3 50.00<br />
2 - 3.3 11 RFS9 33 50.00<br />
3 - 5 11 RFS9 5 50.00<br />
4.5 - 7.5 11 RFS9 75 50.00<br />
6 - 10 11 RFS9 10 50.00<br />
9 - 15 11 RFS9 15 50.00<br />
Operational characteristics<br />
– Tripping class: 10A<br />
– Normal operating limits: -4...+130°F (-20...+55°C);<br />
compensation from 5°F (-15°C)<br />
– Storage temperature: -65...+160°F (-55...+70°C)<br />
– Maximum altitude: 9800ft (3000m)<br />
– Mounting position: normally on vertical plane,<br />
±30° admissible<br />
– Fixed to contactor<br />
– Includes: test button and trip indicator<br />
– Auxiliary contacts: 1NO + 1NC.<br />
The appropriate adjustment range of the overload relay<br />
should be selected on the basis of the motor nameplate<br />
full-load current when across the line starting is considered.<br />
NOTE: To facilitate connection between the auxiliary NC<br />
contact of the thermal relay RFS9 and terminal A2 of the<br />
contactor, insert the wire lead into the appropriate conduit<br />
as shown.<br />
5<br />
❶ Suitable for definite-purpose contactor DPBG12.<br />
Certification and compliance<br />
UL listed, for USA and Canada, file E93601.<br />
CSA certified, file LR 054332_0_000, class 3211-03.<br />
Compliant with standards: IEC/EN 60947-1, IEC/EN 60947-4-1.<br />
Accessories<br />
page 5-9<br />
Dimensions<br />
page D-4<br />
Wiring diagrams<br />
page W-5<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com<br />
Technical characteristics<br />
pages TC-32 and 33
5-4<br />
IEC style overload relays<br />
For three-phase starters with BF series contactors<br />
electric<br />
5<br />
Three poles, single<br />
phase sensitive<br />
(three phase)<br />
RF38<br />
11 RF25<br />
11 RF95<br />
❶ Also suitable for earlier BF9-BF40 types with AC<br />
coil and definite-purpose contactors.<br />
❷ Also suitable for earlier BF20 10-BF20 01-<br />
BF20 40- BF25 10-BF25 01-BF25 40 types.<br />
For overload relay 11RF95 0 23, suitable for<br />
BF20 00-BF25 00 types and defnite-purpose<br />
contactor DPBF26A, contact Sales & Technical<br />
Support for pricing and details<br />
❸ Also suitable for earlier BF32-BF40 types with<br />
AC coil and definite-purpose contactor<br />
DPBF32A.<br />
❹ To use with the G270 base, remove the mounted<br />
links and assemble the ones supplied with the<br />
G270.<br />
Adjustment Catalog number Price<br />
range<br />
[A]<br />
$ each<br />
MANUAL OR AUTOMATIC RESET.<br />
Direct mounting on BF09A - BF12A - BF18A - BF25A - BF26A -<br />
BF32A - BF38A contactors ❶.<br />
Independent mounting with RFX38 04 base.<br />
0.1-0.16 RF38 0016 55.00<br />
0.16-0.25 RF38 0025 55.00<br />
0.25-0.4 RF38 0040 55.00<br />
0.4-0.63 RF38 0063 55.00<br />
0.63-1 RF38 0100 55.00<br />
1-1.6 RF38 0160 55.00<br />
1.6-2.5 RF38 0250 55.00<br />
2.5-4 RF38 0400 55.00<br />
4-6.5 RF38 0650 55.00<br />
6.3-10 RF38 1000 55.00<br />
9-14 RF38 1400 55.00<br />
13-18 RF38 1800 63.00<br />
17-23 RF38 2300 63.00<br />
20-25 RF38 2500 63.00<br />
24-32 RF38 3200 98.00<br />
32-38 RF38 3800 98.00<br />
MANUAL RESET.<br />
Direct mounting on BF9C-BF12C-BF16C-BF20C-BF25C-BF32C-<br />
BF40C contactors ❶.<br />
Independent mounting with G230 base.<br />
0.14 - 0.23 11 RF25 023 55.00<br />
0.2 - 0.33 11 RF25 033 55.00<br />
0.3 - 0.5 11 RF25 05 55.00<br />
0.45 - 0.75 11 RF25 075 55.00<br />
0.6 - 1 11 RF25 1 55.00<br />
0.9 - 1.5 11 RF25 1V5 55.00<br />
1.4 - 2.3 11 RF25 2V3 55.00<br />
2 - 3.3 11 RF25 33 55.00<br />
3 - 5 11 RF25 5 55.00<br />
4.5 - 7.5 11 RF25 75 55.00<br />
6 - 10 11 RF25 10 55.00<br />
9 - 15 11 RF25 15 55.00<br />
14 - 23 11 RF25 23 63.00<br />
17 - 26 11 RF25 26 73.00<br />
Direct mounting on BF20C-BF25C contactors ❷.<br />
Complete with G291 links.<br />
Independent mounting with G270 base ❹.<br />
20 - 33 11 RF95 1 33 130.00<br />
28 - 42 11 RF95 1 42 145.00<br />
Direct mounting on BF32C-BF40C contactors ❸.<br />
Complete with G260 links. Independent mounting with G270 base ❹.<br />
20 - 33 11 RF95 2 33 130.00<br />
28 - 42 11 RF95 2 42 145.00<br />
35 - 50 11 RF95 2 50 151.00<br />
46 - 65 11 RF95 2 65 170.00<br />
Direct mounting on BF50-BF110 and BF50C-BF110C<br />
contactors. Complete with G261 links.<br />
Independent mounting with G270 base ❹.<br />
20 - 33 11 RF95 3 33 130.00<br />
28 - 42 11 RF95 3 42 145.00<br />
35 - 50 11 RF95 3 50 151.00<br />
46 - 65 11 RF95 3 65 170.00<br />
60 - 82 11 RF95 3 82 186.00<br />
70 - 95 11 RF95 3 95 203.00<br />
90 - 110 11 RF95 3 110 227.00<br />
Operational characteristics<br />
– Tripping class: 10A<br />
– Normal operating limits: -4...+130°F (-20...+55°C);<br />
compensation from 5°F (-15°C)<br />
– Storage temperature: -65...+160°F (-55...+70°C)<br />
– Maximum altitude: 9800ft (3000m)<br />
– Mounting position: normally on vertical plane,<br />
±30° admissible<br />
– Fixed to contactor<br />
– Includes: test button and trip indicator<br />
– Auxiliary contacts: 1NO + 1NC.<br />
Version without single-phase sensitivity is available on<br />
request. Contact Sales & Technical Support for the relative<br />
catalog numbers and pricing.<br />
The appropriate adjustment range of the overload relay<br />
should be selected on the basis of the motor nameplate<br />
full-load current when across the line starting is considered.<br />
NOTE: To facilitate connection between the auxiliary NC<br />
contact of the thermal relay RF25 or RF95 and terminal A2<br />
of the contactor, insert the wire lead into the appropriate<br />
conduit as shown.<br />
Certification and compliance<br />
UL listed, for USA and Canada, file E93601.<br />
CSA certified, file LR 054332_0_000, class 3211-03 except<br />
for RF38.<br />
Compliant with standards: IEC/EN 60947-1, IEC/EN 60947-4-1.<br />
Accessories<br />
page 5-9<br />
Dimensions<br />
pages D-4 to 6<br />
Wiring diagrams<br />
page W-5<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com<br />
Technical characteristics<br />
pages TC-32 and 33
electric<br />
IEC style overload relays<br />
For three-phase starters with BF series contactors<br />
5-5<br />
Three poles, single<br />
phase sensitive<br />
(three phase)<br />
11 RFA25<br />
11 RFA95<br />
Adjustment Catalog number Price<br />
range<br />
[A]<br />
$ each<br />
AUTOMATIC RESET.<br />
Direct mounting on BF9C-BF12C-BF16C-BF20C-BF25C-BF32C-<br />
BF40C contactors ❶.<br />
Independent mounting with G230 base.<br />
0.14 - 0.23 11 RFA25 023 60.00<br />
0.2 - 0.33 11 RFA25 033 60.00<br />
0.3 - 0.5 11 RFA25 05 60.00<br />
0.45 - 0.75 11 RFA25 075 60.00<br />
0.6 - 1 11 RFA25 1 60.00<br />
0.9 - 1.5 11 RFA25 1V5 60.00<br />
1.4 - 2.3 11 RFA25 2V3 60.00<br />
2 - 3.3 11 RFA25 33 60.00<br />
3 - 5 11 RFA25 5 60.00<br />
4.5 - 7.5 11 RFA25 75 60.00<br />
6 - 10 11 RFA25 10 60.00<br />
9 - 15 11 RFA25 15 60.00<br />
14 - 23 11 RFA25 23 70.00<br />
17 - 26 11 RFA25 26 81.00<br />
Direct mounting on BF20C-BF25C contactors.<br />
Complete with G291 links ❷.<br />
Independent mounting with G270 base ❹.<br />
20 - 33 11 RFA95 1 33 135.00<br />
28 - 42 11 RFA95 1 42 150.00<br />
Direct mounting on BF32C-BF40C.<br />
Complete with G260 links ❸.<br />
Independent mounting with G270 base ❹.<br />
20 - 33 11 RFA95 2 33 135.00<br />
28 - 42 11 RFA95 2 42 150.00<br />
35 - 50 11 RFA95 2 50 156.00<br />
46 - 65 11 RFA95 2 65 175.00<br />
Direct mounting on BF50-BF110 and BF50C-BF110C<br />
contactors.<br />
Complete with G261 links.<br />
Independent mounting with G270 base ❹.<br />
20 - 33 11 RFA95 3 33 139.00<br />
28 - 42 11 RFA95 3 42 150.00<br />
35 - 50 11 RFA95 3 50 156.00<br />
46 - 65 11 RFA95 3 65 175.00<br />
60 - 82 11 RFA95 3 82 191.00<br />
70 - 95 11 RFA95 3 95 208.00<br />
90 - 110 11 RFA95 3 110 232.00<br />
❶ Also suitable for earlier BF9-BF40 types with AC coil and definite-purpose<br />
contactors.<br />
❷ Also suitable for earlier BF20 10-BF20 01-BF20 40- BF25 10-BF25 01-BF25 40<br />
types.<br />
For overload relay 11RFA95, suitable for BF20 00-BF25 00 types and<br />
definite-purpose contactor, DPBF26A contact Sales & Technical Support for<br />
pricing and details.<br />
❸ Also suitable for earlier BF32-BF40 types with AC coil and definite-purpose<br />
contactor DPBF32A.<br />
❹ To use with the G270 base, remove the mounted links and assemble the ones<br />
supplied with the G270.<br />
Operational characteristics<br />
– Tripping class: 10A<br />
– Normal operating limits: -4...+130°F (-20...+55°C);<br />
compensation from 5°F (-15°C)<br />
– Storage temperature: -65...+160°F (-55...+70°C)<br />
– Maximum altitude: 9800ft (3000m)<br />
– Mounting position: normally on vertical plane,<br />
±30° admissible<br />
– Fixed to contactor or independent mounting<br />
– Includes: test button and trip indicator<br />
– Auxiliary contacts: 1NO + 1NC.<br />
The appropriate adjustment range of the overload relay<br />
should be selected on the basis of the motor nameplate<br />
full-load current when across the line starting is considered.<br />
NOTE: To facilitate connection between the auxiliary NC<br />
contact of the thermal relay RFA25 or RFA95 and terminal<br />
A2 of the contactor, insert the wire lead into the appropriate<br />
conduit as shown.<br />
Certification and compliance<br />
UL listed, for USA and Canada, file E93601.<br />
CSA certified, file LR 054332_0_000, class 3211-03.<br />
Compliant with standards: IEC/EN 60947-1,<br />
IEC/EN 60947-4-1.<br />
5<br />
Accessories<br />
page 5-9<br />
Dimensions<br />
pages D-4 to 6<br />
Wiring diagrams<br />
page W-5<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com<br />
Technical characteristics<br />
pages TC-32 and 33
5-6<br />
IEC style overload relays<br />
For single-phase starters with BF series contactors<br />
electric<br />
5<br />
Two poles<br />
(single phase)<br />
RFS38<br />
11 RFS25<br />
11 RFS95<br />
Adjustment Catalog number Price<br />
range<br />
[A]<br />
$ each<br />
MANUAL OR AUTOMATIC RESET.<br />
Direct mounting on BF09A - BF12A - BF18A - BF25A - BF26A -<br />
BF32A - BF38A contactors ❶.<br />
Independent mounting with RFX38 04 base.<br />
0.1-0.16 RFS38 0016 50.00<br />
0.16-0.25 RFS38 0025 50.00<br />
0.25-0.4 RFS38 0040 50.00<br />
0.4-0.63 RFS38 0063 50.00<br />
0.63-1 RFS38 0100 50.00<br />
1-1.6 RFS38 0160 50.00<br />
1.6-2.5 RFS38 0250 50.00<br />
2.5-4 RFS38 0400 50.00<br />
4-6.5 RFS38 0650 50.00<br />
6.3-10 RFS38 1000 50.00<br />
9-14 RFS38 1400 50.00<br />
13-18 RFS38 1800 58.00<br />
17-23 RFS38 2300 58.00<br />
20-25 RFS38 2500 58.00<br />
24-32 RFS38 3200 93.00<br />
32-38 RFS38 3800 93.00<br />
MANUAL RESETTING.<br />
Direct mounting on BF9C-BF12C-BF16C-BF20C-BF25C-BF32C-<br />
BF40C contactors ❶.<br />
Independent mounting with G230 base.<br />
0.14 - 0.23 11 RFS25 023 50.00<br />
0.2 - 0.33 11 RFS25 033 50.00<br />
0.3 - 0.5 11 RFS25 05 50.00<br />
0.45 - 0.75 11 RFS25 075 50.00<br />
0.6 - 1 11 RFS25 1 50.00<br />
0.9 - 1.5 11 RFS25 1V5 50.00<br />
1.4 - 2.3 11 RFS25 2V3 50.00<br />
2 - 3.3 11 RFS25 33 50.00<br />
3 - 5 11 RFS25 5 50.00<br />
4.5 - 7.5 11 RFS25 75 50.00<br />
6 - 10 11 RFS25 10 50.00<br />
9 - 15 11 RFS25 15 50.00<br />
14 - 23 11 RFS25 23 58.00<br />
17 - 26 11 RFS25 26 68.00<br />
Direct mounting on BF20C-BF25C contactors.<br />
Complete with G291 links ❷.<br />
Independent mounting with G270 base ❹.<br />
20 - 33 11 RFS95 1 33 115.00<br />
28 - 42 11 RFS95 1 42 130.00<br />
Direct mounting on BF32C-BF40C contactors ❸.<br />
Complete with G260 links.<br />
Independent mounting with G270 base ❹.<br />
20 - 33 11 RFS95 2 33 115.00<br />
28 - 42 11 RFS95 2 42 130.00<br />
Operational characteristics<br />
– Tripping class: 10A<br />
– Normal operating limits: -4...+130°F (-20...+55°C);<br />
compensation from 5°F (-15°C)<br />
– Storage temperature: -65...+160°F (-55...+70°C)<br />
– Maximum altitude: 9800ft (3000m)<br />
– Mounting position: normally on vertical plane,<br />
±30° admissible<br />
– Fixed to contactor or independent mounting<br />
– Includes: test button and trip indicator<br />
– Auxiliary contacts: 1NO + 1NC.<br />
The appropriate adjustment range of the thermal overload<br />
relay should be selected on the basis of the motor<br />
nameplate full-load current when direct starting is<br />
considered.<br />
NOTE: To facilitate connection between the auxiliary NC<br />
contact of the thermal relay RFS25 or RFS95 and terminal<br />
A2 of the contactor, insert the wire lead into the appropriate<br />
conduit as shown.<br />
Certification and compliance<br />
UL listed, for USA and Canada, file E93601.<br />
CSA certified, file LR 054332_0_000, class 3211-03 except<br />
for RFS38.<br />
Compliant with standards: IEC/EN 60947-1, IEC/EN 60947-4-1.<br />
❶ Also suitable for earlier BF9-BF40 types with AC coil and definite-purpose<br />
contactors.<br />
❷ Also suitable for earlier BF20 10-BF20 01-BF20 40- BF25 10-BF25 01-BF25 40<br />
types.<br />
❸ Also suitable for earlier BF32-BF40 types with AC coil and definite-purpose<br />
contactor DPBF32A.<br />
❹ To use with the G270 base, remove the mounted links and assemble the ones<br />
supplied with the G270.<br />
Accessories<br />
page 5-9<br />
Dimensions<br />
pages D-4 to 7<br />
Wiring diagrams<br />
page W-5<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com<br />
Technical characteristics<br />
pages TC-32 and 33
electric<br />
IEC style overload relays<br />
For single-phase starters with BF series contactors<br />
5-7<br />
Two poles<br />
(single phase)<br />
11 RFSA25<br />
Adjustment Catalog number Price<br />
range<br />
[A]<br />
$ each<br />
AUTOMATIC RESET.<br />
Direct mounting on BF9C-BF12C-BF16C-BF20C-BF25C-BF32C-<br />
BF40C contactors ❶.<br />
Independent mounting with G230 base.<br />
0.14 - 0.23 11 RFSA25 023 55.00<br />
0.2 - 0.33 11 RFSA25 033 55.00<br />
0.3 - 0.5 11 RFSA25 05 55.00<br />
0.45 - 0.75 11 RFSA25 075 55.00<br />
0.6 - 1 11 RFSA25 1 55.00<br />
0.9 - 1.5 11 RFSA25 1V5 55.00<br />
1.4 - 2.3 11 RFSA25 2V3 55.00<br />
2 - 3.3 11 RFSA25 33 55.00<br />
3 - 5 11 RFSA25 5 55.00<br />
4.5 - 7.5 11 RFSA25 75 55.00<br />
6 - 10 11 RFSA25 10 55.00<br />
9 - 15 11 RFSA25 15 55.00<br />
14 - 23 11 RFSA25 23 65.00<br />
17 - 26 11 RFSA25 26 76.00<br />
Operational characteristics<br />
– Tripping class: 10A<br />
– Normal operating limits: -4...+130°F (-20...+55°C);<br />
compensation from 5°F (-15°C)<br />
– Storage temperature: -65...+160°F (-55...+70°C)<br />
– Maximum altitude: 9800ft (3000m)<br />
– Mounting position: normally on vertical plane,<br />
±30° admissible<br />
– Fixed to contactor or independent mounting<br />
– Includes: test button and trip indicator<br />
– Auxiliary contacts: 1NO + 1NC.<br />
The appropriate adjustment range of the overload relay<br />
should be selected on the basis of the motor nameplate<br />
full-load current when across the line starting is considered.<br />
NOTE: To facilitate connection between the auxiliary NC<br />
contact of the thermal relay RFSA25 and terminal A2 of the<br />
contactor, insert the wire lead into the appropriate conduit<br />
as shown.<br />
5<br />
❶ Also suitable for earlier BF9-BF40 types with AC coil and definite-purpose<br />
contactors.<br />
Certification and compliance<br />
UL listed, for USA and Canada, file E93601.<br />
CSA certified, file LR 054332_0_000, class 3211-03.<br />
Compliant with standards: IEC/EN 60947-1, IEC/EN 60947-4-1.<br />
Accessories<br />
page 5-9<br />
Dimensions<br />
page D-4<br />
Wiring diagrams<br />
page W-5<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com<br />
Technical characteristics<br />
pages TC-32 and 33
5-8<br />
IEC style overload relays<br />
For three-phase starters<br />
electric<br />
5<br />
Three-pole, single<br />
phase sensitive<br />
(three phase)<br />
RF200 - RF420<br />
Adjustment Catalog number Price<br />
range<br />
[A]<br />
$ each<br />
MANUAL OR AUTOMATIC RESET.<br />
Separate mounting ❶.<br />
60 - 100 11 RF200 100 400.00<br />
75 - 125 11 RF200 125 400.00<br />
90 - 150 11 RF200 150 400.00<br />
120 - 200 11 RF200 200 400.00<br />
Separate mounting ❶.<br />
150 - 250 11 RF420 250 500.00<br />
180 - 300 11 RF420 300 500.00<br />
250 - 420 11 RF420 420 500.00<br />
❶ Connecting links between contactor and relay are not included.<br />
Direct mounting on contactor is possible with the following links:<br />
G372 to fix RF200 on B115-B145-B180<br />
G373 to fix RF200 on B250-B310-B400<br />
G375 to fix RF420 on B145-B180<br />
G376 to fix RF420 on B250-B310-B400.<br />
See page 5-9 for connecting link details.<br />
NOTE: Contact Sales & Technical Support for overload relays to be used with<br />
B500-B630 contactors.<br />
Operational characteristics<br />
– Tripping class: 10A<br />
– Normal operating limits: -4...+130°F (-20...+55°C);<br />
compensation from 5°F (-15°C)<br />
– Storage temperature: -65...+160°F (-55...+70°C)<br />
– Maximum altitude: 9800ft (3000m)<br />
– Mounting position: normally on vertical plane,<br />
±30° admissible<br />
– Fixed to contactor or independent mounting<br />
– Includes: test button and trip indicator<br />
– Auxiliary contacts: 1NO + 1NC.<br />
Version without single-phase sensitivity is available on<br />
request. Contact Sales & Technical Support for the relative<br />
catalog numbers and pricing.<br />
The appropriate adjustment range of the overload relay<br />
should be selected on the basis of the motor nameplate<br />
full-load current when across the line starting is considered.<br />
Certification and compliance<br />
UL listed, for USA and Canada, file E93601.<br />
Compliant with standards: IEC/EN 60947-1, IEC/EN 60947-4-1.<br />
Combinations<br />
G258<br />
(for RF...95 2)<br />
G262<br />
(for RF...95 3)<br />
G372<br />
G373<br />
G375<br />
G376<br />
G270<br />
G361<br />
G363<br />
RF...200<br />
RF...420<br />
G230<br />
RFX38 04<br />
RF...95 1<br />
RF...95 2<br />
RF...95 3<br />
G233<br />
G228<br />
RF...9<br />
RF...25<br />
G244<br />
RF...38<br />
RB6<br />
RFX38 01<br />
Accessories<br />
page 5-9<br />
Dimensions<br />
pages D-4 to 7<br />
Wiring diagrams<br />
page W-5<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com<br />
Technical characteristics<br />
pages TC-32 and 33
electric<br />
IEC style overload relays<br />
Accessories for overload relays<br />
5-9<br />
RFX38 02<br />
Description Catalog number Price<br />
$ each<br />
Set of links for direct contactor mounting.<br />
RF..95 on BF20 00-BF25 00 11 G430 ❶ 8.00<br />
contactor: BF20 10-BF20 01 11 G291 8.00<br />
BF25 10-BF25 01<br />
BF20 40-BF25 40<br />
AC and DC types<br />
BF32-BF40 11 G260 ❷ 8.00<br />
AC and DC types<br />
BF50-BF110 11 G261 11.00<br />
AC and DC types<br />
RF...200 on B115-B145-B180 11 G372 29.00<br />
contactor: B250-B310-B400 11 G373 44.00<br />
Remote reset (G228) operational characteristics<br />
Control circuit voltage<br />
AC (50/60Hz) V 12 - 550<br />
Power consumption in AC VA 300<br />
Minimum reset time ms 20<br />
NOTE: Coil can remain supplied for a maximum interval of<br />
500ms; 3 consecutive operations are allowed, followed by a<br />
5 minute interval.<br />
It is recommended to use the wiring diagram on page W-5.<br />
Certification and compliance<br />
UL recognition listed, for USA and Canada, file E93601.<br />
CSA certified, file LR 054332_0_000, class 3211-02 for<br />
links and G361 and G363 protections..<br />
Compliant with standards: IEC/EN 60947-1, IEC/EN 60947-4-1.<br />
RFX38 03<br />
11 G258<br />
11 G262<br />
RF...420 on B145-B180 11 G375 39.00<br />
contactor: B250-B310-B400 11 G376 46.00<br />
Protection cover for thermal overload relay-contactor assembly.<br />
RF38 on contactor BF09A - BF12A - RFX38 02 4.00<br />
BF18A - BF25A ❸<br />
RF38 on contactor BF26A - BF32A - RFX38 03 4.00<br />
BF38A ❸<br />
Finger protection for power terminals.<br />
RF...95 2 11 G258 ❹ 4.50<br />
RF...95 3 11 G262 ❹ 4.50<br />
RF...200 11 G361 17.00<br />
RF...420 11 G363 33.00<br />
Independent mounting.<br />
Screw fixing or 35mm DIN rail (IEC/EN 60715) mounting.<br />
RF...38 RFX38 04 12.50<br />
RF25 11 G230 11.50<br />
RF95 11 G270❺ 42.00<br />
Remote reset.<br />
All types 11 G228❻ 46.00<br />
Anti-tamper shield.<br />
RF...38 BFX38 01 5.00<br />
All types 11 G233 2.50<br />
<strong>Electric</strong> button with 1NO contact.<br />
RF...9 - RF...25 - RF...95 11 G244 7.00<br />
Marking element.<br />
RF...9 - RF...25 - RF...95 11 RB6 3.20<br />
5<br />
11 G230<br />
RFX38 04<br />
Protection cover for thermal overload relay-contactor assembly<br />
BF09A-BF25A<br />
BF26A-BF38A<br />
11 G228<br />
11 G244<br />
❶ G430 can be used for connection between RF...95<br />
and definite purpose contactor DPBF26A.<br />
❷ G260 can also be used for connection between<br />
RF...95 and definite-purpose contactor DPBF32A.<br />
❸ Suitable con definite-purpose contactors<br />
DPBF...A too.<br />
❹ Front finger protection IP20 is warranted to<br />
contactor-thermal relay connections.<br />
❺ To use with the G270 base, remove the mounted<br />
links and assemble the ones supplied with the<br />
G270.<br />
❻ Replace with voltage digits.<br />
Indicate: 024 for 24V, 120 for 110-125V and 230<br />
for 200-240V.<br />
All are suitable for 50/60Hz.<br />
Other voltage values are available on request.<br />
Contact Sales & Technical Support for details.<br />
RF...38<br />
RFX38 02<br />
RF...38<br />
RFX38 03<br />
Dimensions<br />
page D-15<br />
Wiring diagrams<br />
page W-5<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com
PAGE 6-2<br />
ENCLOSED COMPACT STARTERS<br />
WITH OVERLOAD RELAY<br />
• Single and three-phase motor ratings, 1A to 95A<br />
• With reset button or with start-stop/reset<br />
buttons.<br />
PAGE 6-4<br />
EMPTY NON-METALLIC ENCLOSURES<br />
• Versions without pushbuttons, with reset button<br />
only or with start-stop/reset buttons<br />
• Suitable to contain BG mini-contactors or BF09A<br />
to BF95 contactors, up to 95A rating.<br />
REVERSING CONTACTOR ASSEMBLIES<br />
• Unwired and wired versions<br />
• Single and three-phase motor ratings,<br />
6A to 185A<br />
• AC or DC control coil.<br />
PAGE 6-8<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com
6<br />
IEC STYLE STARTERS<br />
Compact, economical IEC style<br />
starters, full voltage<br />
non-reversing<br />
Non-metallic enclosures<br />
Available with RESET or<br />
START/STOP push buttons in cover<br />
Enclosures available separately for<br />
customer assembly<br />
Reversing contactor assemblies<br />
PLANET -SWITCH<br />
SEC. PAGE<br />
Full-voltage - accross the line - starters<br />
Non-reversing - three phase<br />
Enclosed compact starter with overload relay . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6- 2<br />
Empty non-metallic enclosures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6- 4<br />
Reversing - three poles<br />
With operating coil in AC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6- 8<br />
With operating coil in DC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6- 9<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com
6-2<br />
IEC style starters<br />
Full-voltage - across the line - non reversing - three-phase type<br />
electric<br />
M0 R M0 P M1 R M1 P M2 R M2 P<br />
Maximum horsepower ratings Catalog number Price<br />
Single Phase ❶ Three Phase ❶ ❷ ❸ ❹<br />
120V 240V 200V 240V 480V 600V $ each<br />
M0 ENCLOSURE<br />
Reset button only<br />
1<br />
/2 1 1 /2 2 3 5 5 M0 R009 12 ❶ ❷ ❸ 163.00<br />
1<br />
/2 1 1 /2 3 3 7 1 /2 10 M0 R012 12 ❶ ❷ ❸ 179.00<br />
6<br />
Start - Stop/Reset Pushbuttons<br />
1<br />
/2 1 2 3 5 5 M0 P009 12 ❶ ❷ ❸ 177.00<br />
1<br />
/2 1 1 /2 3 3 7 1 /2 10 M0 P012 12 ❶ ❷ ❸ 193.00<br />
M1 ENCLOSURE<br />
Reset button only<br />
3<br />
/4 2 3 3 5 7 1 /2 M1 R009 12 ❶ ❷ ❸ 194.00<br />
1 3 5 5 10 15 M1 R018 12 ❶ ❷ ❸ 221.00<br />
Start - Stop/Reset Pushbuttons<br />
3<br />
/4 2 3 3 5 7 1 /2 M1 P009 12 ❶ ❷ ❸ 208.00<br />
1 3 5 5 10 15 M1 P018 12 ❶ ❷ ❸ 235.00<br />
M2 ENCLOSURE<br />
Reset button only<br />
2 3 7 1 /2 7 1 /2 15 15 M2 R025 12 ❶ ❷ ❸ 270.00<br />
3 7 1 /2 10 10 20 25 M2 R032 12 ❶ ❷ ❸ 344.00<br />
Start - Stop/Reset Pushbuttons<br />
2 3 7 1 /2 7 1 /2 15 15 M2 P025 12 ❶ ❷ ❸ 284.00<br />
3 7 1 /2 10 10 20 25 M2 P032 12 ❶ ❷ ❸ 358.00<br />
M3 ENCLOSURE<br />
Reset button only<br />
5 10 10 15 30 40 11 M3 BRF R50 ❶ ❷ ❸ 481.00<br />
–– –– 20 25 50 60 11 M3 BRF R65 ❶ ❷ ❸ 570.00<br />
–– –– 25 30 60 75 11 M3 BRF R80 ❶ ❷ ❸ 672.00<br />
–– –– 30 30 60 75 11 M3 BRF R95 ❶ ❷ ❸ 696.00<br />
Start - Stop/Reset Pushbuttons<br />
5 10 10 15 30 40 11 M3 BRF P50 ❶ ❷ ❸ 496.00<br />
–– –– 20 25 50 60 11 M3 BRF P65 ❶ ❷ ❸ 585.00<br />
–– –– 25 30 60 75 11 M3 BRF P65 ❶ ❷ ❸ 585.00<br />
–– –– 30 30 60 75 11 M3 BRF P95 ❶ ❷ ❸ 711.00<br />
Accessories<br />
page 6-4<br />
Dimensions<br />
pages D-16 and 17<br />
Wiring diagrams<br />
page W-6<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com
electric<br />
IEC style starters<br />
Full-voltage - across the line - non reversing - three-phase type<br />
6-3<br />
11 M3 BRF R 11 M3 BRF P<br />
Contactor<br />
included<br />
Enclosure<br />
Size Size Degree of protection<br />
BG09 10A M0 RA IP65<br />
BG12 10A M0 RA IP65<br />
BG09 10A M0 PA IP65<br />
BG12 10A M0 PA IP65<br />
BF09 10A M1 RA IP65<br />
BF18 10A M1 RA IP65<br />
BF09 10A M1 PA IP65<br />
BF18 10A M1 PA IP65<br />
BF25 10A M2 RA IP65<br />
BF32 00A M2 RA IP65<br />
BF25 10A M2 RA IP65<br />
BF32 00A M2 RA IP65<br />
BF50 00 M3 IP54<br />
BF65 00 M3 IP54<br />
BF80 00 M3 IP54<br />
BF95 00 M3 IP54<br />
BF50 00 M3 IP54<br />
BF65 00 M3 IP54<br />
BF80 00 M3 IP54<br />
BF95 00 M3 IP54<br />
General characteristics<br />
Full-voltage starters in non-metallic enclosure are<br />
supplied complete with three-pole single-phase sensitive<br />
thermal overload relay.<br />
The enclosure has knockout entries. The M0 and M1<br />
versions have all entries with diameter 0.8in / 21mm<br />
while the M2, diameter 0.8/1in - 21/26mm and M3,<br />
diameter 1.5in / 37mm. Entries are located on upper and<br />
lower surfaces and must be completed with adequate wire<br />
conduits to maintain the enclosure degree of protection.<br />
Protection fuses are to be mounted externally by the user.<br />
<strong>Electric</strong>al life<br />
500,000 cycles at the maximum rate of 600 cycles/hour.<br />
Certifications and compliance<br />
UL listings for USA and Canada pending for M0 - M1 -<br />
M2 types only.<br />
Compliant with standards: IEC/EN 60947-1,<br />
IEC/EN 60947-4-1, UL508.<br />
Coil codes ❶❷<br />
Voltage range 60Hz<br />
Coil Code<br />
24V 02460<br />
120V 12060<br />
220-240V 23060<br />
440-480V 46060<br />
575V 57560<br />
Overload relay codes ❶❸<br />
For M0 types<br />
For M1-M2 types<br />
Amp Range Relay code Amp Range Relay code<br />
0.14 - 0.23 023 0.1-0.16 A0<br />
0.2 - 0.33 033 0.16-0.25 A1<br />
0.3 - 0.5 05 0.25-0.4 A2<br />
0.45 - 0.75 075 0.4-0.63 A3<br />
0.6 - 1 1 0.63-1 A4<br />
0.9 - 1.5 1V5 1-1.6 A5<br />
1.4 - 2.3 2V3 1.6-2.5 A6<br />
2 - 3.3 33 2.5-4 A7<br />
3 - 5 5 4-6.5 A8<br />
4.5 - 7.5 75 6.3-10 A9<br />
6 - 10 10 9-14 B0<br />
9 - 15 15 13-18 B1<br />
For M3 types 17-23 B2<br />
14 - 23 23 20-25 B3<br />
20 - 33 33 24-32 B4<br />
28 - 42 42 32-38 B5<br />
35 - 50 50<br />
46 - 65 65<br />
60 - 82 82<br />
70 - 95 95<br />
❶ For a starter without overload relay, replace “12” of the catalog<br />
number with “10” and complete with a coil code only. Consult Sales<br />
& Technical Support for pricing. Example: M1 P009 10 02460.<br />
For single phase starter, replace “12” of the catalog number with<br />
“13” and complete with coil and relay codes as mentioned below.<br />
For a M0 starter with automatic reset relay, replace “12” of the<br />
catalog number with “15 and complete with coil and relay codes as<br />
mentioned below.<br />
❷ Select the coil voltage required from the coil codes table and add<br />
the coil code to the catalog number.<br />
❸ After adding the coil code, select the Amp range required from the<br />
Overload relay codes tables, depending on the enclosure type, and<br />
add the relay code to the catalog number.<br />
For single phase starters, refer to note ❶ above.<br />
Three-phase starters can be used on single phase provided they are<br />
wired properly, refer to wiring diagrams on page W-6 or see the<br />
instructions leaflet with the starter.<br />
Examples of complete catalog numbers:<br />
M1 P009 12 12060 A9<br />
M2 R032 13 23060 B4<br />
M1 enclosure, Start-Stop/Reset buttons,<br />
BF09A contactor, 6.3-10A overload, 3 phase,<br />
and 120VAC coil<br />
M2 enclosure, Reset only, BF32A contactor,<br />
24-32A overload, single phase, and<br />
230VAC coil.<br />
❹ See page 6-5 for main starter components. Contact Sales &<br />
Technical Support for catalog numbers and pricing not listed.<br />
6<br />
Accessories<br />
page 6-4<br />
Dimensions<br />
pages D-16 and 17<br />
Wiring diagrams<br />
page W-6<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com
6-4<br />
IEC style starters<br />
Full-voltage - across the line - starters - Accessories<br />
electric<br />
6<br />
Empty non-metallic<br />
enclosures<br />
M...N<br />
M...PA<br />
M...RA<br />
Accessories and<br />
spare parts<br />
MX 00<br />
Contactor type Overload Degree Catalog Price<br />
❶ relay of number<br />
❷ protect. ❸<br />
$ each<br />
Enlcosures without external push-buttons.<br />
BG06, BG09, RFA9 IP65 M0N 25.00<br />
BG12<br />
BF09A, BF12A, RF38 IP65 M1N 28.00<br />
BF18A<br />
BF25A, BF26A RF38 IP65 M2N 47.00<br />
BF32A❹<br />
BF50, BF65, RF95 3 IP54 11 M3 172.00<br />
BF80, BF95<br />
Enclosures with Start-Stop/Reset buttons.<br />
BG06, BG09, RF9 IP65 M0PA 45.00<br />
BG12<br />
BF09A, BF12A, RF38 IP65 M1PA 48.00<br />
BF18A<br />
BF25A, BF26A, RF38 IP65 M2PA 67.00<br />
BF32A❹<br />
BF50, BF65, RF95 3 IP54 11 M3P 196.00<br />
BF80, BF95<br />
Enclosures with Reset button.<br />
BG06, BG09, RF9 IP65 M0RA 31.00<br />
BG12<br />
BF09A, BF12A, RF38 IP65 M1RA 34.00<br />
BF18A<br />
BF25A, BF26A RF38 IP65 M2RA 53.00<br />
BF32A❹<br />
BF50, BF65, RF95 3 IP54 11 M3R 185.00<br />
BF80, BF95<br />
❶ To be purchased separately; refer to page 3-4 for contactor choice.<br />
❷ To be purchased separately; refer to pages 4-2 to 4-6 for thermal overload<br />
relay choice.<br />
❸ Contact Sales & Technical Support also for catalog number not listed.<br />
❹ Reversing contactor assemblies can be fitted as well. Refer to illustrations on<br />
page 6-7.<br />
Description Catalog Price<br />
number<br />
$ each<br />
Button actuator fixing adapter MX 00 4.50<br />
for M0, M1 and M2 enclosures<br />
Stop/Reset button extension MX 10 1.50<br />
rod for M0 enclosure<br />
Stop/Reset button extension MX 11 1.50<br />
rod for M1 enclosure<br />
Stop/Reset button extension MX 12 1.50<br />
rod for M2 enclosure<br />
Mounting base for 8LM2T C... MX 20 3.00<br />
contact on M0 enclosure<br />
Mounting base for 8LM2T C... MX 21 3.00<br />
contact on M1 or M2 enclosure<br />
Enclosure<br />
type<br />
A<br />
M0 12<br />
M1 18<br />
M2 32<br />
M3 95<br />
Maximum operating current<br />
(≤440V)<br />
General characteristics<br />
Enclosures are supplied with the following accessories:<br />
Enclosure M0 RA M1 RA M2 RA M0 PA M1 PA M2 PA<br />
Mounting MX 20 1<br />
base MX 21 1 1<br />
Stop/Reset<br />
button<br />
8 LP2T B1176 1 1 1<br />
8 LP2T B2104 1 1 1<br />
Start button<br />
8 LP2T B1113 1 1 1<br />
Contact element<br />
for Start button<br />
8 LM2T E10 1 1 1<br />
Operator mounting<br />
adapter MX 00 1 1 1 2 2 2<br />
Start/Reset button<br />
extension rod<br />
MX 10 1 1<br />
MX 11 1 1<br />
MX 12 1 1<br />
Threaded plug for<br />
unused holes<br />
8 LM2T A129 1 1 1<br />
M3 P and M3 R type enclosures are equipped with the<br />
following accessories::<br />
– Enclsoure with Reset button: Earth terminal and 2<br />
G285 auxiliary terminals<br />
– Enclosure with Start and Stop/Reset buttons: N/O<br />
contact for start function, earth terminal and 2 G285<br />
auxiliary terminals.<br />
NOTE: Enclosures can house the following contactors with<br />
the relative overload relay:<br />
M0 = BG<br />
M1 = BF09A-BF18A<br />
M2 = BF25A-BF32A❹<br />
M3 = BF50-BF95<br />
Certifications and compliance<br />
UL listing for USA and Canada for M0 - M1 - M2 types<br />
only is pending completion.<br />
Compliant with standards: IEC/EN 60947-1,<br />
IEC/EN 60947-4-1.<br />
MX 20<br />
MX 21<br />
Dimensions<br />
pages D-16 and 17<br />
Wiring diagrams<br />
page W-6<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com
electric<br />
IEC style starters<br />
Full-voltage - across the line - non reversing - accessories<br />
6-5<br />
M0 R009 12 M0 P0012 12<br />
M1 R009 12 M1 P018 12<br />
Composition of complete starters or components to be assembled by the customer.<br />
The customer can choose to purchase the various components as per list below.<br />
The three columns in boldface indicate components for full-voltage starters consenting the customer to assemble different<br />
contactor-relay combinations. The column on the extreme right indicates the completely-assembled types given on page 6-2 and 6-3.<br />
For catalog numbers of each component, refer to the relevant section; e.g. for contactors, see section 3.<br />
Enclosure Protection Push Contactor Overload Auxiliary Complete<br />
degree buttons Relay Contacts ❶ Starter available<br />
3-Phase 1-Phase<br />
M0RA IP65 RESET BG06 10A RF9 RFS9 1 NO ––<br />
BG09 10A RF9 RFS9 1 NO M0 R009<br />
BG12 10A RF9 RFS9 1 NO M0 R012<br />
M0PA IP65 START and BG06 10A RF9 RFS9 1 NO ––<br />
STOP/RESET BG09 10A RF9 RFS9 1 NO M0 P009<br />
BG12 10A RF9 RFS9 1 NO M0 P012<br />
M1RA IP65 RESET BF09 10A RF38 RFS38 1 NO M1 R009<br />
BF12 10A RF38 RFS38 1 NO ––<br />
BF18 10A RF38 RFS38 1 NO M1 R018<br />
M1PA IP65 START and BF09 10A RF38 RFS38 1 NO M1 P009<br />
STOP/RESET BF12 10A RF38 RFS38 1 NO ––<br />
BF18 10A RF38 RFS38 1 NO M1 R018<br />
M2RA IP65 RESET BF25 10A RF38 RFS38 1 NO M2 R025<br />
BF26 00A RF38 RFS38 –– ––<br />
BF32 00A RF38 RFS38 –– M2 R032<br />
M2PA IP65 START and BF25 10A RF38 RFS38 1 NO M2 P025<br />
STOP/RESET BF26 00A RF38 RFS38 –– ––<br />
BF32 00A RF38 RFS38 –– M2 P032<br />
M3R IP54 RESET BF50 00 RF95 3 RFS95 –– M3BRF R50<br />
BF65 00 RF95 3 –– –– M3BRF R65<br />
BF80 00 RF95 3 –– –– M3BRF R80<br />
BF95 00 RF95 3 –– –– M3BRF R95<br />
M3P IP54 START and BF50 00 RF95 3 RFS95 –– M3BRF P50<br />
STOP/RESET BF65 00 RF95 3 –– –– M3BRF P65<br />
BF80 00 RF95 3 –– –– M3BRF P80<br />
BF95 00 RF95 3 –– –– M3BRF P95<br />
❶ All versions are suitable for mounting other NO (normally open) and NC (normally closed) auxiliary contacts. Contact Sales & Technical Support for information<br />
about possible configurations.<br />
NOTE: These starters have an electric life rating of 500,000 cycles, at the maximum rate of 600 cycles per hour.<br />
6<br />
Dimensions<br />
pages D-16 and 17<br />
Wiring diagrams<br />
page W-6<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com
6-6<br />
IEC style starters<br />
Full-voltage - across the line - starters - Composition<br />
electric<br />
M0 P009 12...<br />
M0 P012 12...<br />
M0 P009 10...<br />
M0 P012 10...<br />
M0PA<br />
M0 R009 12...<br />
M0 R012 12...<br />
M0 R009 10...<br />
M0 R012 10...<br />
M0RA<br />
M0N<br />
6<br />
M1 P009 12...<br />
M1 P018 12...<br />
M1 P009 10...<br />
M1 P018 10...<br />
M1PA<br />
M1 R009 12...<br />
M1 R018 12...<br />
M1 R009 10...<br />
M1 R018 10...<br />
M1RA<br />
M1N<br />
M2 P02512...<br />
M2 P032 12...<br />
M2 P025 10...<br />
M2 P032 10...<br />
M2PA<br />
M2 R025 12...<br />
M2 R032 12...<br />
M2 R025 10...<br />
M2 R032 10...<br />
M2RA<br />
M2N<br />
Dimensions<br />
pages D-16 and 17<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com
electric<br />
IEC style starters<br />
Full-voltage - across the line - starters - Composition<br />
6-7<br />
The starter enclosures are designed to facilitate<br />
numerous circuit and assembly variations.<br />
Inside the enclosure, in addition to the starter,<br />
composed by a contactor and thermal overload<br />
relay, timers, level control and protection relays of<br />
the Modulo series can be fitted. These devices can<br />
be the 1-module type for the M0 and M1<br />
enclosures or 2-module type for the M2.<br />
The enclosure covers can be equipped with<br />
various type of actuators and pilot lights, per the<br />
following details.<br />
1) Upper position 1: The cover must be drilled in<br />
this position, with a 0.89in (22.5mm) diameter,<br />
by the user; 8LM2TIL10 or 8LP2TIL pilot light<br />
can be fitted.<br />
To fit the 8LM2TIL pilot light, the MX 00 fixing<br />
adapter and the mounting base, type<br />
MX 20 for M0, or type MX 21 for M1 and M2,<br />
must also be purchased. The lamp holder is<br />
snapped on to this mounting base.<br />
2) Middle position 2: Based on the enclosure<br />
type, in this position, the user finds either the<br />
Start button or a plug in the 0.89in (22.5mm)<br />
hole.<br />
Various actuators can be fitted in this position,<br />
such as flush or extended push buttons,<br />
selectors or pilot lights, as illustrated in the<br />
drawing. To fit the actuators, the MX 00 fixing<br />
adapter, not required for LP2TIL pilot lights,<br />
and the mounting base, type MX 20 for M0, or<br />
type MX 21 for M1 and M2, must also be<br />
purchased. The contact or lamp holder<br />
elements are snapped on to this mounting<br />
base.<br />
3) Lower position 3: The Stop/Reset button is<br />
mounted in this position, except for the<br />
enclosure without buttons. This button<br />
activates the thermal overload relay via a<br />
mechanical operator. In eventual applications<br />
without thermal overload relay, this button can<br />
be removed and the hole stopped up by the<br />
threaded plug 8 LM2T A129.<br />
8 LM2T C<br />
8 LM2T L<br />
8 LM2T EL400<br />
8 LM2T ZL230<br />
❶<br />
MX 00<br />
8 LM2T C<br />
MX 20 (M0)<br />
MX 21 (M1 - M2)<br />
1<br />
2<br />
3<br />
8 LM2T A140<br />
8 LM2T A140<br />
8 LM2T IL10<br />
8 LP2T IL<br />
8 L...2T BL<br />
8 L...2T B1<br />
8 L...2T B2<br />
6<br />
❶ 0.69in.<br />
1.4in/35.8mm for M2 enclosure only.<br />
8 L...2T S3<br />
8 L...2T S<br />
8 L...2T B71...<br />
8 L...2T B72...<br />
8 L...2T BL71...<br />
8 L...2T BL72...<br />
8 L...2T B73...<br />
N. 2 BF09A<br />
BG<br />
BF09A<br />
BF18A<br />
BF25A<br />
BF32A<br />
N. 2 BF25A<br />
BFX50 02<br />
RF9<br />
RF38<br />
RF38<br />
RF38<br />
Dimensions<br />
pages D-16 and 17<br />
Wiring diagrams<br />
page W-6<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com
6-8<br />
IEC style contactors<br />
Three-pole reversing contactors with operating coil in AC<br />
electric<br />
UL maximum horsepower ratings UL UL Maximum current Auxiliary Catalog number Price<br />
Single phase Three phase Amp resistive Inductive Resistive contacts<br />
115V 230V 200V 230V 460V 575V rating Amps AC3 AC1 (per contactor)<br />
[HP] [HP] [HP] [HP] [HP] [HP] [A] [A] [A] NO NC $ each<br />
Unwired version - AC coil<br />
Reversing mini-contactor assembly, mechanically interlocked. Terminals: clamp screw.<br />
1<br />
/3 1 1 1 /2 2 3 3 16 –– 6 16 1 0 11 BGU06 10 A ❶ 147.00<br />
0 1 11 BGU06 01 A ❶ 147.00<br />
1<br />
/2 1 1 /2 2 3 5 5 20 –– 9 20 1 0 11 BGU09 10 A ❶ 177.00<br />
6<br />
11 BGU09 01A<br />
BFU...A<br />
11 BGR09 01A<br />
0 1 11 BGU09 01 A ❶ 177.00<br />
1<br />
/2 1 1 /2 3 3 7 1 /2 10 20 –– 12 20 1 0 11 BGU12 10 A ❶ 203.00<br />
0 1 11 BGU12 01 A ❶ 203.00<br />
Reversing contactor assembly, mechanically interlocked.<br />
Terminals: clamp screw for BFU09-BFU40; lug clamp for BFU50-BFU110.<br />
3<br />
/4 2 3 3 5 7 1 /2 25 –– 9 25 1 0 BFU09 10A ❶ 180.00<br />
0 1 BFU09 01A ❶ 180.00<br />
1 2 5 5 7 1 /2 10 28 –– 12 25 1 0 BFU12 10A ❶ 222.00<br />
0 1 BFU12 01A ❶ 222.00<br />
1 3 5 5 102 15 32 –– 18 32 1 0 BFU18 10A ❶ 238.00<br />
0 1 BFU18 01A ❶ 238.00<br />
2 3 7 1 /2 7 1 /2 15 15 32 –– 25 32 1 0 BFU25 10A ❶ 266.00<br />
0 1 BFU25 01A ❶ 266.00<br />
2 5 7 1 /2 7 1 /2 15 20 45 –– 26 45 0 0 BFU26 00A ❶ 278.00<br />
3 7 1 /2 10 10 20 25 55 –– 32 56 0 0 BFU32 00A ❶ 326.00<br />
3 7 1 /2 10 15 30 30 55 –– 38 56 0 0 BFU38 00A ❶ 394.00<br />
5 10 10 15 30 40 90 –– 50 90 0 0 11 BFU50 00 ❶ 470.00<br />
–– –– 20 25 50 60 110 –– 65 110 0 0 11 BFU65 00 ❶ 598.00<br />
–– –– 25 30 60 75 125 –– 80 125 0 0 11 BFU80 00 ❶ 696.00<br />
–– –– 30 30 60 75 125 –– 95 125 0 0 11 BFU95 00 ❶ 744.00<br />
–– –– 30 40 75 100 125 –– 110 125 0 0 11 BFU110 00 ❶ 848.00<br />
AC/DC coil<br />
Reversing contactor assembly, mechanically interlocked. Terminals: Screw nut.<br />
–– –– 30 40 75 100 110 160 110 160 0 0 11 BFU115 00 ❷ 1149.00<br />
–– –– 50 60 100 125 150 220 150 250 0 0 11 BFU145 00 ❷ 1607.00<br />
–– –– 60 75 150 150 180 260 185 275 0 0 11 BFU180 00 ❷ 2083.00<br />
Wired version - AC coil<br />
Reversing mini-contactor assembly, mechanically interlocked, pre-wired with load and line power and auxiliary wiring.<br />
Terminals: clamp screw ❸.<br />
1<br />
/2 1 1 /2 2 3 5 5 20 –– 9 20 0 1 11 BGR09 01 A ❶ 148.00<br />
1<br />
/2 1 1 /2 3 3 7 1 /2 10 20 –– 12 20 0 1 11 BGR12 01 A ❶ 180.00<br />
Reversing contactor assemblies, mechanically interlocked, pre-wired with load and line power wiring. Terminals: clamp screw ❹.<br />
3<br />
/4 2 3 3 5 7 1 /2 25 –– 9 25 0 1 BFA009 42 ❶ 214.00<br />
1 2 5 5 7 1 /2 10 24 –– 12 25 0 1 BFA012 42 ❶ 268.00<br />
1 2 5 5 7 1 /2 10 24 –– 16 25 0 1 BFA018 42 ❶ 285.00<br />
2 5 7 1 /2 7 1 /2 15 20 40 –– 25 40 0 1 BFA025 42 ❶ 311.00<br />
❶ Complete catalog number with coil digit per following table.<br />
AC coil digit Voltage range<br />
02460 24V 60Hz<br />
12060 120V 60Hz<br />
23060 200-240V 60Hz<br />
46060 440-480V 60Hz<br />
57560 575V 60Hz<br />
Other coil voltage and frequency values are available on request.<br />
NOTE: No coil change or replacement is possible.<br />
❷ Complete catalog number with coil digit per following table.<br />
Voltage range<br />
AC coil digit<br />
AC/DC<br />
024 24V<br />
120 110/125V<br />
220 200/240V<br />
460 440/480V<br />
Other coil voltage values are available on request.<br />
❸ Mini-contactor assembly for mounting on printed circuit boards<br />
is available on request. Contact Sales & Technical Support for<br />
details.<br />
An overload relay cannot be directly mounted on the contactors.<br />
Use the RF25 and the G230 independent mounting base.<br />
❹ An overload relay can be directly mounted on the contactors. Use<br />
the RF38 type and consult page 5-4 for details.<br />
Positively guided contacts<br />
See page TC-26 for contactors with NC contacts.<br />
See page TC-27 for add-on auxiliary contacts.<br />
Certifications and compliance<br />
BGR types: UL listed for USA and Canada, file E93602.<br />
BFA types: cULus pending.<br />
Compliant with standards: IEC/EN 60947-1, UL508,<br />
IEC/EN 60947-4-1.<br />
Dimensions<br />
page D-18<br />
Wiring diagrams<br />
page W-5<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com
electric<br />
IEC style contactors<br />
Three-pole reversing contactors with operating coil in DC<br />
6-9<br />
UL maximum horsepower ratings UL UL Maximum current Auxiliary Catalog number Price<br />
Single phase Three phase Amp resistive Inductive Resistive contacts<br />
115V 230V 200V 230V 460V 575V rating Amps AC3 AC1 (per contactor)<br />
[HP] [HP] [HP] [HP] [HP] [HP] [A] [A] [A] NO NC $ each<br />
Unwired version - DC coil.<br />
Reversing mini-contactor assembly, mechanically interlocked. Terminals: clamp screw.<br />
1<br />
/3 1 1 1 /2 2 3 3 16 –– 6 16 1 0 11 BGU06 10 D ❶ 147.00<br />
0 1 11 BGU06 01 D ❶ 147.00<br />
1<br />
/2 1 1 /2 2 3 5 5 20 –– 9 20 1 0 11 BGU09 10 D ❶ 177.00<br />
11 BGU09 01D<br />
0 1 11 BGU09 01 D ❶ 177.00<br />
1<br />
/2 1 1 /2 3 3 7 1 /2 10 20 –– 12 20 1 0 11 BGU12 10 D ❶ 203.00<br />
11 BFU...C<br />
11 BGR09 01D<br />
0 1 11 BGU12 01 D ❶ 203.00<br />
Reversing contactor assembly, mechanically interlocked.<br />
Terminals: clamp screw for BFU9C-BFU40C; lug clamp for BFU50C-BFU110C.<br />
3<br />
/4 2 3 3 5 7 1 /2 22 –– 9 25 1 0 11 BFU9C 10 ❷ 230.00<br />
0 1 11 BFU9C 01 ❷ 230.00<br />
1 2 5 5 7 1 /2 10 24 –– 12 25 1 0 11 BFU12C 10 ❷ 280.00<br />
0 1 11 BFU12C 01 ❷ 280.00<br />
1 2 5 5 7 1 /2 10 24 –– 16 25 1 0 11 BFU16C 10 ❷ 296.00<br />
0 1 11 BFU16C 01 ❷ 296.00<br />
1 1 /2 3 5 5 10 15 32 –– 20 40 1 0 11 BFU20C 10 ❷ 312.00<br />
0 1 11 BFU20C 01 ❷ 312.00<br />
2 5 7 1 /2 7 1 /2 15 20 40 –– 25 40 1 0 11 BFU25C 10 ❷ 348.00<br />
0 1 11 BFU25C 01 ❷ 348.00<br />
3 7 1 /2 7 1 /2 10 20 25 52 –– 32 55 0 0 11 BFU32C 00 ❷ 414.00<br />
3 7 1 /2 10 15 30 30 52 –– 40 60 0 0 11 BFU40C 00 ❷ 492.00<br />
5 10 10 15 30 40 90 –– 50 90 0 0 11 BFU50C 00 ❷ 596.00<br />
–– –– 20 25 50 60 110 –– 65 110 0 0 11 BFU65C 00 ❷ 732.00<br />
–– –– 25 30 60 75 125 –– 80 125 0 0 11 BFU80C 00 ❷ 848.00<br />
–– –– 30 30 60 75 125 –– 95 125 0 0 11 BFU95C 00 ❷ 940.00<br />
–– –– 30 40 75 100 125 –– 110 125 0 0 11 BFU110C 00 ❷ 1048.00<br />
AC/DC coil. Unwired reversing contactors, mechanically interlocked.<br />
–– –– 30 40 75 100 110 160 110 160 0 0 11 BFU115 00 ❸ 1149.00<br />
–– –– 50 60 100 125 150 220 150 250 0 0 11 BFU145 00 ❸ 1607.00<br />
–– –– 60 75 150 150 180 260 185 275 0 0 11 BFU180 00 ❸ 2083.00<br />
Wired version. DC coil.<br />
Reversing mini-contactors assembly, mechanically interlocked, pre-wired with load and line power and auxiliary wiring.<br />
Terminals: clamp screw ❹❺.<br />
1<br />
/2 1 1 /2 2 3 5 5 20 –– 9 20 0 1 11 BGR09 01 D ❶ 188.00<br />
1<br />
/2 1 1 /2 3 3 7 1 /2 10 20 –– 12 20 0 1 11 BGR12 01 D ❶ 214.00<br />
Reversing contactor assembly, mechanically interlocked, pre-wired with load and line power wiring. Terminals: clamp screw ❺.<br />
3<br />
/4 2 3 3 5 7 1 /2 22 –– 9 25 0 1 11 BFT9C 01 ❷ 257.00<br />
1 2 5 5 7 1 /2 10 24 –– 12 25 0 1 11 BFT12C 01 ❷ 309.00<br />
1 2 5 5 7 1 /2 10 24 –– 16 25 0 1 11 BFT16C 01 ❷ 326.00<br />
2 5 7 1 /2 7 1 /2 15 20 40 –– 25 40 0 1 11 BFT25C 01 ❷ 376.00<br />
6<br />
❶ Complete the catalog number with coil digit. Standard voltages (coil digit)<br />
are: 024-110V. Other coil voltage values are available on request.<br />
NOTE: No coil change or replacement is possible.<br />
❷ Complete the catalog number with coil digit. Standard voltages (coil digit)<br />
are: 024-110V. Other coil voltage values are available on request.<br />
❸ Complete catalog number with coil digit per following table.<br />
Voltage range<br />
AC coil digit<br />
AC/DC<br />
024 24V<br />
120 110/125V<br />
220 200/240V<br />
460 440/480V<br />
Other coil voltage values are available on request.<br />
❹ Mini-contactor assembly for mounting on printed circuit boards is<br />
available on request. Contact Sales & Technical Support for details.<br />
❺ An overload relay can not be directly mounted on the contactors. Use the<br />
RF25 type with the G230 independent mounting base.<br />
Positively guided contacts<br />
See page TC-26 for contactors with NC contacts.<br />
See page TC-27 for add-on auxiliary contacts.<br />
Certifications and compliance<br />
BGR types: UL listed for USA and Canada, file E93602.<br />
Compliant with standards: IEC/EN 60947-1,<br />
IEC/EN 60947-4-1, UL508.<br />
Dimensions<br />
page D-18<br />
Wiring diagrams<br />
page W-5<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com
PAGES 7-2 TO 6<br />
METAL BUTTON OPERATORS<br />
• Momentary flush, extended and guarded<br />
• Push-push flush and extended<br />
• Mushroom-head<br />
• Mechanical reset<br />
• Illuminated.<br />
PAGES 7-4 AND 7<br />
DOUBLE AND TRIPLE TOUCH OPERATORS<br />
• Double touch with or without indicator<br />
• Triple touch.<br />
METAL SELECTOR OPERATORS<br />
• Knob<br />
• Lever<br />
• Key<br />
• Illuminated.<br />
PAGES 7-5 AND 7<br />
METAL POTENTIOMETER DRIVES<br />
• Graduated scale<br />
• Variable index.<br />
PAGE 7-8<br />
METAL JOYSTICKS<br />
• 2 directions<br />
• 4 directions<br />
• 2 directions with mechanical interlock<br />
• 4 directions with mechanical interlock<br />
• Complete with auxiliary contacts.<br />
PAGE 7-9<br />
PAGES 7-10 TO 14<br />
PLASTIC BUTTON OPERATORS<br />
• Momentary flush, extended and guarded<br />
• Push-push flush and extended<br />
• Mushroom-head<br />
• Mechanical reset<br />
• Illuminated.<br />
PAGES 7-12 AND 15<br />
PLASTIC DOUBLE AND TRIPLE TOUCH OPERATORS<br />
• Double touch with or without indicator<br />
• Triple touch.<br />
PLASTIC SELECTOR OPERATORS<br />
• Knob<br />
• Lever<br />
• Key<br />
• Illuminated.<br />
PAGES 7-13 AND 15<br />
PILOT LIGHTS<br />
• Monoblock LED<br />
• Conventional monoblock.<br />
PAGE 7-16<br />
CONTROL STATIONS<br />
• 1 to 5 positions without operators<br />
• Complete units with 1 button.<br />
PAGE 7-16<br />
ADD-ON ELEMENTS<br />
• Mounting adapter<br />
• Contact elements<br />
• Lamp holders<br />
• LED integrated lamp holders.<br />
PAGE 7-17<br />
ACCESSORIES<br />
• Labelling<br />
• Label holders<br />
• Bulbs<br />
• Spare parts.<br />
PAGES 7-19 TO 21<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com
7<br />
PUSH BUTTONS AND PILOT DEVICES - 22MM<br />
Metal and plastic series<br />
Oil tight and water tight type 4/4X<br />
IP65 construction<br />
Rugged, modular construction with<br />
rear of panel locking screws on<br />
mounting adapter<br />
Contacts with double break,<br />
positive opening and self cleaning<br />
Contacts rated for low electronic<br />
applications-5 milliamps at<br />
12 volts.<br />
PLANET -SWITCH<br />
CLICK<br />
These operators consent to easy and quick<br />
installation with neither the use of special tools<br />
nor the need for subsequent adjustments or<br />
rotations.<br />
SEC. PAGE<br />
Metal series<br />
Push-button operators, momentary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7- 2<br />
Push-push button operators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7- 3<br />
Mushroom-head push-button operators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7- 3<br />
Mechanical reset button, momentary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7- 4<br />
Double-touch button operators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7- 4<br />
Triple-touch button operators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7- 4<br />
Selector operators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7- 5<br />
Illuminated button actuators, momentary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7- 6<br />
Illuminated push-push operators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7- 6<br />
Illuminated mushroom-head actuators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7- 6<br />
Illuminated selector operators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7- 7<br />
Double-touch button operators with indicator . . . . . . . . . . . . . . . . . . . . . . . . . . . 7- 7<br />
Pilot light heads . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7- 8<br />
Potentiometer drives . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7- 8<br />
Joysticks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7- 9<br />
Plastic series<br />
Push-button operators, momentary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7- 10<br />
Push-push button operators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7- 11<br />
Mushroom-head push-button operators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7- 11<br />
Mechanical reset button, momentary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7- 12<br />
Double-touch button operators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7- 12<br />
Triple-touch button operators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7- 12<br />
Selector operators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7- 13<br />
Illuminated button operators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7- 14<br />
Illuminated mushroom-head operators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7- 14<br />
Illuminated selector operators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7- 14<br />
Double-touch button operators with indicator . . . . . . . . . . . . . . . . . . . . . . . . . . 7- 15<br />
Monoblock LED pilot lights, steady light . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7- 16<br />
Monoblock pilot lights . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7- 16<br />
Control stations 7- 16<br />
Add-on elements 7- 17<br />
Accessories and spare parts 7- 19<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com
7-2<br />
Push buttons and pilot devices, 22mm<br />
Metal series<br />
electric<br />
7<br />
Push-button<br />
operators,<br />
momentary<br />
8 LM2T B104<br />
8 LM2T B204<br />
8 LM2T B303<br />
Push-button<br />
operators,<br />
momentary, with<br />
inscription<br />
8 LM2T B1104<br />
8 LM2T B2104<br />
Color Catalog number Price<br />
$ each<br />
Flush (without mounting adapter), momentary.<br />
Black 8 LM2T B102 6.50<br />
Green 8 LM2T B103 6.50<br />
Red 8 LM2T B104 6.50<br />
Yellow 8 LM2T B105 6.50<br />
Blue 8 LM2T B106 6.50<br />
White 8 LM2T B108 6.50<br />
Extended (without mounting adapter), momentary.<br />
Black 8 LM2T B202 7.00<br />
Green 8 LM2T B203 7.00<br />
Red 8 LM2T B204 7.00<br />
Yellow 8 LM2T B205 7.00<br />
Blue 8 LM2T B206 7.00<br />
White 8 LM2T B208 7.00<br />
Guarded (without mounting adapter), momentary.<br />
Black 8 LM2T B302 12.00<br />
Green 8 LM2T B303 12.00<br />
Red 8 LM2T B304 12.00<br />
Yellow 8 LM2T B305 12.00<br />
Blue 8 LM2T B306 12.00<br />
White 8 LM2T B308 12.00<br />
Inscription Color Catalog number Price<br />
$ each<br />
Flush (without mounting adapter), momentary.<br />
O Black 8 LM2T B1102 8.00<br />
Red 8 LM2T B1104 8.00<br />
I Green 8 LM2T B1113 8.00<br />
White 8 LM2T B1118 8.00<br />
II Green 8 LM2T B1123 8.00<br />
White 8 LM2T B1128 8.00<br />
STOP Black 8 LM2T B1132 8.00<br />
Red 8 LM2T B1134 8.00<br />
❶<br />
Black 8 LM2T B1142 8.00<br />
White 8 LM2T B1148 8.00<br />
❷<br />
Black 8 LM2T B1152 8.00<br />
White 8 LM2T B1158 8.00<br />
START Green 8 LM2T B1163 8.00<br />
White 8 LM2T B1168 8.00<br />
R Blue 8 LM2T B1176 8.00<br />
White 8 LM2T B1178 8.00<br />
RESET Blue 8 LM2T B1196 8.00<br />
Black 8 LM2T B1502 8.00<br />
Black 8 LM2T B1512 8.00<br />
Extended (without mounting adapter), momentary.<br />
O Black 8 LM2T B2102 9.50<br />
Red 8 LM2T B2104 9.50<br />
STOP Black 8 LM2T B2132 9.50<br />
Red 8 LM2T B2134 9.50<br />
❶ Arrow inscription can be used to indicate right or left.<br />
❷ Arrow inscription can be used to indicate up or down.<br />
Operational characteristics<br />
– Ambient conditions:<br />
• Operating temperature: -13...+140°F (-25...+60°C)<br />
• Storage temperature: -40...+158°F (-40...+70°C)<br />
– Any mounting position is allowed<br />
– Degree of protection: IP65.<br />
Materials<br />
An aluminum and zinc alloy (zama) is used for the metal<br />
part whereas plastic parts are made of polyamide and<br />
polycarbonate.<br />
Mechanical endurance<br />
Operating force: 1.76lb / 0.8kg (operator).<br />
Mechanical life: 1,000,000 cycles.<br />
Mounting adapter<br />
See page 7-17.<br />
Catalog number: 8 LM2T AU120.<br />
Operators latch onto the mounting adapter with a simple<br />
rotation.<br />
The adapter is fixed to the mounting surface by means of<br />
incorporated screws (Tmax = 7.1lbin / 0.8 Nm).<br />
Contactselements<br />
See page 7-17.<br />
Catalog numbers:<br />
8 LM2T C10 (1NO)<br />
8 LM2T CF10 (1NO Faston)<br />
8 LM2T C10A (EM)<br />
8 LM2T C01 (1NC)<br />
8 LM2T CF01 (1NC Faston)<br />
8 LM2T C01D (LB)<br />
Contact elements snap onto the mounting adapter.<br />
Up to 6 contacts can be fitted on the mounting adapter:<br />
2 on the left, 2 at the center and 2 on the right.<br />
To mount contacts in the center position, use the<br />
accessory: LM2T A140 (see page 7-21).<br />
CLICK<br />
LM2T A140❸<br />
❸ The action plug LM2T A140 for the center position is not standard<br />
supplied and must be purchased separately.<br />
Certifications and compliance<br />
UL listed for USA and Canada, File E93601.<br />
Compliant with standards: IEC/EN 60947-1, IEC/EN 60947-5-1.<br />
Add-on blocks<br />
pages 7-17 and 18<br />
Accessories and spare parts<br />
pages 7-19 to 21<br />
Dimensions<br />
page D-19<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com
electric<br />
Push buttons and pilot devices, 22mm<br />
Metal series<br />
7-3<br />
Push-push button<br />
operators<br />
8 LM2T Q104<br />
8 LM2T Q204<br />
Color Catalog number Price<br />
$ each<br />
Flush (without mounting adapter). Maintained, push to release.<br />
Black 8 LM2T Q102❶ 16.00<br />
Green 8 LM2T Q103❶ 16.00<br />
Red 8 LM2T Q104❶ 16.00<br />
Yellow 8 LM2T Q105❶ 16.00<br />
Blue 8 LM2T Q106❶ 16.00<br />
White 8 LM2T Q108❶ 16.00<br />
Extended (without mounting adapter). Maintained, push to<br />
release.<br />
Black 8 LM2T Q202❶ 19.00<br />
Green 8 LM2T Q203❶ 19.00<br />
Red 8 LM2T Q204❶ 19.00<br />
Yellow 8 LM2T Q205❶ 19.00<br />
Blue 8 LM2T Q206❶ 19.00<br />
White 8 LM2T Q208❶ 19.00<br />
❶ Use only the early-make type, LM2T C10A.<br />
No normally open contact element, LM2T C10 must be used with this type of<br />
button operator.<br />
A maximum of 2 contact elements can be mounted only.<br />
Operational characteristics<br />
– Ambient conditions:<br />
• Operating temperature: -13...+140°F (-25...+60°C)<br />
• Storage temperature: -40...+158°F (-40...+70°C)<br />
– Any mounting position is allowed<br />
– Degree of protection: IP66 (IP65 only for LM2T B654<br />
operator).<br />
Materials<br />
An aluminum and zinc alloy (zama) is used for the metal<br />
part whereas plastic parts are made of polyamide and<br />
polycarbonate.<br />
Mechanical endurance<br />
Operating force: 1.76lb / 0.8kg (operator).<br />
Mechanical life:<br />
– Push-push operators: 500,000 cycles.<br />
– Mushroom head buttons: 1,000,000 cycles.<br />
– Mushroom head latch buttons: 300,000 cycles.<br />
Mounting adapter<br />
See page 7-17.<br />
Catalog number: 8 LM2T AU120.<br />
Operators latch onto the mounting adapter with a simple<br />
rotation.<br />
The adapter is fixed to the mounting surface by means of<br />
incorporated screws (Tmax = 7.14lbin / 0.8 Nm).<br />
Mushroom head<br />
push-button<br />
operators<br />
8 LM2T B6144<br />
8 LM2T B6164<br />
8 LM2T B6244<br />
8 LM2T B6344<br />
8 LM2T B6544<br />
Color Catalog number Price<br />
$ each<br />
Momentary. Ø 40 mm (1.6in)<br />
(without mounting adapter).<br />
Black 8 LM2T B6142 12.50<br />
Green 8 LM2T B6143 12.50<br />
Red 8 LM2T B6144 12.50<br />
Yellow 8 LM2T B6145 12.50<br />
Blue 8 LM2T B6146 12.50<br />
Momentary. Ø 60 mm (2.4in)<br />
(without mounting adapter).<br />
Black 8 LM2T B6162 16.00<br />
Green 8 LM2T B6163 16.00<br />
Red 8 LM2T B6164 16.00<br />
Yellow 8 LM2T B6165 16.00<br />
Blue 8 LM2T B6166 16.00<br />
Maintained, pull to release. Ø 40 mm (1.6in)<br />
(without mounting adapter).<br />
Black 8 LM2T B6242 19.80<br />
Red 8 LM2T B6244 19.80<br />
Maintained, twist to release. Ø 40 mm (1.6in)<br />
(without mounting adapter).<br />
Black 8 LM2T B6342 22.00<br />
Red 8 LM2T B6344 22.00<br />
Maintained, twist key to release. Ø 40 mm (1.6in), keyed<br />
(without mounting adapter).<br />
Black 8 LM2T B6542 47.00<br />
8 LM2T B6542G...❷ 50.00<br />
Red 8 LM2T B6544 47.00<br />
8 LM2T B6544G...❷ 50.00<br />
Maintained, twist to release, mechanical latching EN418<br />
compliant. Ø 40 mm (1.6in) (without mounting adapter).<br />
Red 8 LM2T B6644 42.00<br />
❷ Versions with different key codes.<br />
Complete with the numeric code of the key. The following versions are available:<br />
501, 502, 503, 504, 505, 506, 507, 508, 509, 510.<br />
Example of complete catalog number: 8 LM2T B6542G505.<br />
Contact elements for push-push operators<br />
See page 7-17.<br />
Catalog numbers: 8 LM2T C10A (EM)<br />
8 LM2T C01 (1NC)<br />
Contact elements snap onto the mounting adapter.<br />
Up to 2 contacts can be fitted on the mounting adapter:<br />
1 each on the right and left.<br />
Contact elements for mushroom-head button operators<br />
Catalog numbers: 8 LM2T C10 (1NO)<br />
8 LM2T CF10 (1NO Faston)<br />
8 LM2T C10A (EM)<br />
8 LM2T C01 (1NC)<br />
8 LM2T CF01 (1NC Faston)<br />
8 LM2T C01D (LB)<br />
Contact elements snap onto the mounting adapter.<br />
Up to 4 contacts can be fitted on the mounting adapter<br />
with LM2T B624... and LM2T B6644 types.<br />
Up to 6 contacts can be fitted on the mounting adapter<br />
with all the rest: 2 on the left, 2 at the right and 2 at the<br />
center LM2T A140 (see page 7-21).<br />
To mount the contacts in the center position with<br />
LM2T B614... and LM2T B616... types only, use the action<br />
plug LM2T A140 (see page 7-21).<br />
CLICK<br />
LM2T A140❸<br />
❸ The action plug LM2T A140 for the center position is not standard<br />
supplied and must be purchased separately.<br />
7<br />
Certifications and compliance<br />
UL listed for USA and Canada, File E93601.<br />
Compliant with standards: IEC/EN 60947-1, IEC/EN 60947-5-1.<br />
8 LM2T B6644<br />
Add-on blocks<br />
pages 7-17 and 18<br />
Accessories and spare parts<br />
pages 7-19 to 21<br />
Dimensions<br />
page D-19<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com
7-4<br />
Push buttons and pilot devices, 22mm<br />
Metal series<br />
electric<br />
Mechanical reset<br />
buttons, complete<br />
unit, momentary<br />
8 LM2T R1196<br />
Color Catalog number Price<br />
$ each<br />
Flush (0.12in / 5.2 mm stroke).<br />
Adjustable length 0-5in (0-123 mm).<br />
Black 8 LM2T R1002 12.00<br />
Green 8 LM2T R1003 12.00<br />
Red 8 LM2T R1004 12.00<br />
Blue 8 LM2T R1006 12.00<br />
Blue (RESET) 8 LM2T R1196❶ 13.00<br />
Extended (0.12in / 5.2 mm stroke).<br />
Adjustable length 0-5in (0-123 mm).<br />
Red 8 LM2T R2004 13.00<br />
Complete with mounting adapter as well as the rod.<br />
❶ With “RESET” inscription on operator.<br />
Operational characteristics<br />
– Ambient conditions:<br />
• Operating temperature: -13...+140°F (-25...+60°C)<br />
• Storage temperature: -40...+158°F (-40...+70°C)<br />
– Any mounting position is allowed<br />
– Degree of protection: IP65 for reset buttons; IP40 for<br />
touch operators.<br />
Materials<br />
An aluminum and zinc alloy (zama) is used for the metal<br />
part whereas plastic parts are made of polyamide and<br />
polycarbonate.<br />
Mechanical endurance<br />
Operating force for reset buttons: 1.76lb / 0.8kg (operator)<br />
Mechanical life: 1,000,000 cycles.<br />
7<br />
Double-touch<br />
operators,<br />
momentary<br />
8 LM2T B713<br />
Color Symbols Catalog number Price<br />
$each<br />
Two flush push-buttons (without mounting adapter).<br />
Both momentary.<br />
Black/Red none 8 LM2T B7112 9.60<br />
Green/Red none 8 LM2T B7113 9.60<br />
White/Black none 8 LM2T B7114 9.60<br />
Black/Red I-O 8 LM2T B7122 10.90<br />
Green/Red I-O 8 LM2T B7123 10.90<br />
White/Black I-O 8 LM2T B7124 10.90<br />
Green/Red Start/Stop 8 LM2T B7133 10.90<br />
One extended and one flush push-buttons (without<br />
mounting adapter). Both momentary.<br />
Black/Red none 8 LM2T B7212 10.50<br />
Green/Red none 8 LM2T B7213 10.50<br />
White/Black none 8 LM2T B7214 10.50<br />
Black/Red I-O 8 LM2T B7222 10.60<br />
Green/Red I-O 8 LM2T B7223 10.60<br />
White/Black I-O 8 LM2T B7224 10.60<br />
Green/Red Start/Stop 8 LM2T B7233 10.60<br />
Mounting adapter<br />
See page 7-17.<br />
Catalog number: 8 LM2T AU120.<br />
Operartors latch onto the mounting adapter with a simple<br />
rotation.<br />
The adapter is fixed to the mounting surface by means of<br />
incorporated screws (Tmax = 7.1lbin / 0.8 Nm).<br />
Contact elements for touch operators<br />
See page 7-17.<br />
Catalog numbers: 8 LM2T C10 (1NO)<br />
8 LM2T CF10 (1NO Faston)<br />
8 LM2T C10A (EM)<br />
8 LM2T C01 (1NC)<br />
8 LM2T CF01 (1NC Faston)<br />
8 LM2T C01D (LB)<br />
Contact elements snap onto the mounting adapter.<br />
DOUBLE-TOUCH OPERATORS<br />
Up to 4 contacts can be fitted on the mounting adapter:<br />
2 on the left and 2 on the right.<br />
TRIPLE-TOUCH OPERATORS<br />
Up to 6 contacts can be fitted on the mounting adapter:<br />
2 on the left, 2 in the centre and 2 on the right.<br />
8 LM2T B723<br />
Triple-touch<br />
operators,<br />
momentary<br />
8 LM2T B73...<br />
Colors Marked Catalog Price<br />
in white number $ each<br />
Two external flush and one middle extended buttons<br />
(without mounting adapter) All momentary.<br />
Green 8 LM2T B7345 14.20<br />
Red<br />
Green<br />
STOP<br />
Green 8 LM2T B7355 14.20<br />
Red<br />
Green<br />
STOP<br />
Certifications and compliance<br />
UL listed, for USA and Canada, file E93601.<br />
Compliant with standards: IEC/EN 60947-1, IEC/EN 60947-5-1.<br />
Green 8 LM2T B7365 14.20<br />
Red<br />
Green<br />
STOP<br />
Green 8 LM2T B7375 14.20<br />
Red<br />
Green<br />
STOP<br />
Add-on blocks<br />
pages 7-17 and 18<br />
Accessories and spare parts<br />
pages 7-19 to 21<br />
Dimensions<br />
page D-19<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com
electric<br />
Push buttons and pilot devices, 22mm<br />
Metal series<br />
7-5<br />
Selector switch<br />
operators, knob<br />
8 LM2T S120<br />
Selector switch<br />
operators, lever<br />
8 LM2T S231<br />
Selector switch<br />
operators, key<br />
8 LM2T S320<br />
Type of Catalog number Price<br />
positions<br />
$ each<br />
2 position (without mounting adapter).<br />
8 LM2T S120 11.80<br />
8 LM2T S121 14.00<br />
3 position (without mounting adapter).<br />
8 LM2T S130 11.80<br />
8 LM2T S131 14.00<br />
8 LM2T S132 14.00<br />
8 LM2T S133 14.00<br />
Type of Catalog number Price<br />
positions<br />
$ each<br />
2 position (without mounting adapter).<br />
8 LM2T S220 12.60<br />
8 LM2T S221 14.50<br />
3 position (without mounting adapter).<br />
8 LM2T S230 12.60<br />
8 LM2T S231 14.50<br />
8 LM2T S232 14.50<br />
8 LM2T S233 14.50<br />
Type of Catalog number Price<br />
positions<br />
$ each<br />
2 position (without mounting adapter).<br />
8 LM2T S320 35.00<br />
8 LM2T S320G...❶ 38.00<br />
8 LM2T S321 35.00<br />
8 LM2T S321G...❶ 38.00<br />
8 LM2T S340 36.00<br />
8 LM2T S340G...❶ 39.00<br />
3 position (without mounting adapter).<br />
8 LM2T S330 35.00<br />
8 LM2T S330G...❶ 38.00<br />
8 LM2T S331 35.00<br />
8 LM2T S331G...❶ 38.00<br />
8 LM2T S332❷ 35.00<br />
8 LM2T S332G...❶❷ 38.00<br />
8 LM2T S333❷ 35.00<br />
8 LM2T S333G...❶❷ 38.00<br />
8 LM2T S350 36.00<br />
8 LM2T S350G...❶ 39.00<br />
8 LM2T S360 36.00<br />
8 LM2T S360G...❶ 39.00<br />
8 LM2T S370❷ 36.00<br />
8 LM2T S370G...❶❷ 39.00<br />
8 LM2T S380❷ 36.00<br />
8 LM2T S380G...❶❷ 39.00<br />
8 LM2T S390❷ 36.00<br />
8 LM2T S390G...❶❷ 39.00<br />
❶ Versions with different key codes.<br />
Complete with the numeric code of the key. The following versions are available:<br />
501, 502, 503, 504, 505, 506, 507, 508, 509, 510.<br />
Example of complete code: 8 LM2T S320G505.<br />
❷ Available only on specific request.<br />
Operational characteristics<br />
– Ambient conditions:<br />
• Operating temperature: -13...+140°F (-25...+60°C)<br />
• Storage temperature: -40...+158°F (-40...+70°C)<br />
– Any mounting position is allowed<br />
– Degree of protection: IP65.<br />
Materials<br />
An aluminium and zinc alloy (zama) is used for the metal<br />
part whereas plastic parts are made of polyamide and<br />
polycarbonate.<br />
Mechanical endurance<br />
Mechanical life: 300,000 cycles.<br />
Mounting adapter<br />
See page 6-17.<br />
Catalog number: 8 LM2T AU120.<br />
Operartors latch onto the mounting adapter with a simple<br />
rotation.<br />
The adapter is fixed to the mounting surface by means of<br />
incorporated screws (Tmax = 7.1lbin / 0.8 Nm).<br />
Contact elements for selector operators<br />
See page 7-17.<br />
Catalog numbers: 8 LM2T C10 (1NO)<br />
8 LM2T CF10 (1NO Faston)<br />
8 LM2T C10A (EM)<br />
8 LM2T C01 (1NC)<br />
8 LM2T CF01 (1NC Faston)<br />
8 LM2T C01D (LB)<br />
Contact elements snap onto the mounting adapter.<br />
Up to 4 contacts can be fitted on the mounting adapter:<br />
2 on the left and 2 on the right. For more, contact Sales &<br />
Technical Support for details.<br />
Positions<br />
Angles<br />
2 position 3 position<br />
90°<br />
Maintained position.<br />
Spring return position.<br />
Key withdrawal position.<br />
Special versions<br />
Versions with colored keys are available upon request.<br />
Contact Sales & Technical Support.<br />
Certifications and compliance<br />
UL listed, for USA and Canada, file E93601.<br />
Compliant with standards: IEC/EN 60947-1, IEC/EN 60947-5-1.<br />
45°<br />
45°<br />
7<br />
Add-on blocks<br />
pages 7-17 and 18<br />
Accessories and spare parts<br />
pages 7-19 to 21<br />
Dimensions<br />
page D-19<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com
7-6<br />
Push buttons and pilot devices, 22mm<br />
Metal series<br />
electric<br />
7<br />
Illuminated button<br />
operators<br />
8 LM2T BL104<br />
8 LM2T BL204<br />
Illuminated<br />
push-push button<br />
operators<br />
8 LM2T QL104<br />
8 LM2T QL204<br />
Illuminated<br />
mushroom head<br />
button operators<br />
8 LM2T BL6144<br />
8 LM2T BL6245<br />
Color Catalog number Price<br />
$ each<br />
Flush (with side visibility), momentary<br />
(without mounting adapter).<br />
Green 8 LM2T BL103 10.50<br />
Red 8 LM2T BL104 10.50<br />
Yellow 8 LM2T BL105 10.50<br />
Blue 8 LM2T BL106 10.50<br />
Transparent 8 LM2T BL107 10.50<br />
Extended (without mounting adapter), momentary.<br />
Green 8 LM2T BL203 9.50<br />
Red 8 LM2T BL204 9.50<br />
Yellow 8 LM2T BL205 9.50<br />
Blue 8 LM2T BL206 9.50<br />
Transparent 8 LM2T BL207 9.50<br />
Color Catalog number Price<br />
$ each<br />
Flush (without mounting adapter). Maintained, push to release.<br />
Green 8 LM2T QL103❶ 27.00<br />
Red 8 LM2T QL104❶ 27.00<br />
Yellow 8 LM2T QL105❶ 27.00<br />
Blue 8 LM2T QL106❶ 27.00<br />
Transparent 8 LM2T QL107❶ 27.00<br />
Extended (without mounting adapter). Maintained, push to release.<br />
Green 8 LM2T QL203❶ 30.00<br />
Red 8 LM2T QL204❶ 30.00<br />
Yellow 8 LM2T QL205❶ 30.00<br />
Blue 8 LM2T QL206❶ 30.00<br />
Transparent 8 LM2T QL207❶ 30.00<br />
❶ Use only the early-make type, LM2T C10A.<br />
No normally open contact element, LM2T C10, must be used with this type of<br />
button operator.<br />
A maximum of 2 contact elements can be mounted only.<br />
Color Catalog number Price<br />
$ each<br />
Momentary. Ø 40 mm (1.6in) (without mounting adapter). ❷<br />
Green 8 LM2T BL6143 17.00<br />
Red 8 LM2T BL6144 17.00<br />
Yellow 8 LM2T BL6145 17.00<br />
Blue 8 LM2T BL6146 17.00<br />
White 8 LM2T BL6148 17.00<br />
Maintained, pull to release. Ø 40 mm (1.6in)<br />
(without mounting adapter). ❷<br />
Green 8 LM2T BL6243 31.00<br />
Red 8 LM2T BL6244 31.00<br />
Yellow 8 LM2T BL6245 31.00<br />
Blue 8 LM2T BL6246 31.00<br />
White 8 LM2T BL6248 31.00<br />
❷ The number of contact elements to be mounted is given in the side notes.<br />
Operational characteristics<br />
– Ambient conditions:<br />
• Operating temperature: -13...+140°F (-25...+60°C)<br />
• Storage temperature: -40...+158°F (-40...+70°C)<br />
– Any mounting position is allowed<br />
– Degree of protection: IP65.<br />
Materials<br />
An aluminum and zinc alloy (zama) is used for the metal<br />
part whereas plastic parts are made of polyamide and<br />
polycarbonate.<br />
Mechanical endurance<br />
Operating force: 1.76lb / 0.8kg (operator).<br />
Mechanical life:<br />
– Push-push operators: 500,000 cycles.<br />
– Mushroom head latch operators: 300,000 cycles<br />
– All others: 1,000,000 cycles.<br />
Mounting adapter<br />
See page 7-17.<br />
Catalog number: 8 LM2T AU120.<br />
Operators latch onto the mounting adapter with a simple<br />
rotation.<br />
The adapter is fixed to the mounting surface by means of<br />
incorporated screws (Tmax = 7.14lbin / 0.8 Nm).<br />
Contact elements for push-push operators:<br />
See page 7-17.<br />
Catalog number:<br />
8 LM2T C10A (EM)<br />
8 LM2T C01 (1NC)<br />
Contact elements snap on to the mounting adapter.<br />
Up to 2 contacts can be fitted on the mounting adapter in<br />
a row, 1 each on the right and left, along with the lampholder<br />
in the center position, of which<br />
LM2T DL400, LM2T EL400, LM2T VL230, LM2T ZL230,<br />
LM2T L or LM2T M (see page 7-18).<br />
With lamp-holder LM2T XL, LM2T YL, LM2T FL or LM2T GL,<br />
one contact can be mounted only (see page 7-18).<br />
Contact elements for illuminated momentary button and<br />
mushroom-head operators<br />
See page 7-17.<br />
Catalog numbers: 8 LM2T C10 (1NO)<br />
8 LM2T CF10 (1NO Faston)<br />
8 LM2T C10A (EM)<br />
8 LM2T C01 (1NC)<br />
8 LM2T CF01 (1NC Faston)<br />
8 LM2T C01D (LB)<br />
Contact elements snap onto the mounting adapter.<br />
On LM2T BL1, LM2T BL2 or LM2T BL61 operators, the<br />
following can be fitted on the mounting adapter:<br />
– Up to 4 contacts, 2 each on the left and right, when<br />
one of the following lamp-holders is used:<br />
LM2T DL400, LM2T EL400, LM2T VL230,<br />
LM2T ZL230, LM2T L or LM2T M (see page 7-18).<br />
– Up to 2 contacts, one on top of the other of the same<br />
type only, when one of the following lamp-holders is<br />
used LM2T XL, LM2T YL, LM2T FL or LM2T GL (see<br />
page 7-18).<br />
On LM2T BL62... operator, the following can be fitted on<br />
the mounting adapter:<br />
– Up to 2 contacts, 1 each on the right and left, when<br />
one of the following lamp-holders is used:<br />
LM2T DL400, LM2T EL400, LM2T VL230,<br />
LM2T ZL230, LM2T L or LM2T M (see page 7-18)<br />
– Up to 2 contacts, one on top of the other of the same<br />
type only, when one of the following lamp-holders is<br />
used: LM2T XL, LM2T YL, LM2T FL or LM2T GL (see<br />
page 7-18).<br />
Lamp-holder elements<br />
See pages 7-18.<br />
Bulbs<br />
Maximum recommended power: 1.2W. See page 7-20.<br />
Certifications and compliance<br />
UL listed for USA and Canada, file E93601.<br />
Compliant with standards: IEC/EN 60947-1, IEC/EN 60947-5-1.<br />
Add-on blocks<br />
pages 7-17 and 18<br />
Accessories and spare parts<br />
pages 7-19 to 21<br />
Dimensions<br />
page D-19<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com
electric<br />
Push buttons and pilot devices, 22mm<br />
Metal series<br />
7-7<br />
Double-touch<br />
operators,<br />
momentary, white<br />
indicator<br />
8 LM2T BL7133 8 LM2T BL7233<br />
Illuminated selector<br />
operators<br />
8 LM2T SL1205<br />
8 LM2TA12... A12...❶<br />
❶ The operator is standard supplied with a white<br />
diffuser. Colored diffusers LM2T A12... can be<br />
purchased separately. Refer to page 7-21.<br />
Color Symbol Catalog number Price<br />
$ each<br />
Two flush push-buttons (without mounting adapter).<br />
Both momentary.<br />
Black/Red none 8 LM2T BL7112 10.50<br />
Green/Red none 8 LM2T BL7113 10.50<br />
White/Black none 8 LM2T BL7114 10.50<br />
Black/Red I-O 8 LM2T BL7122 11.60<br />
Green/Red I-O 8 LM2T BL7123 11.60<br />
White/Black I-O 8 LM2T BL7124 11.60<br />
Green/Red Start/Stop 8 LM2T BL7133 11.60<br />
One extended push-buttons (without mounting adapter).<br />
Both momentary.<br />
Black/Red none 8 LM2T BL7212 11.10<br />
Green/Red none 8 LM2T BL7213 11.10<br />
White/Black none 8 LM2T BL7214 11.10<br />
Black/Red I-O 8 LM2T BL7222 12.80<br />
Green/Red I-O 8 LM2T BL7223 12.80<br />
White/Black I-O 8 LM2T BL7224 12.80<br />
Green/Red Start/Stop 8 LM2T BL7233 12.80<br />
Color Type of Catalog number Price<br />
positions<br />
$ each<br />
2 position (without mounting adapter).<br />
Green 8 LM2T SL1203 15.00<br />
Red 8 LM2T SL1204 15.00<br />
Yellow 8 LM2T SL1205 15.00<br />
Blue 8 LM2T SL1206 15.00<br />
White 8 LM2T SL1208 15.00<br />
Green 8 LM2T SL1213 18.00<br />
Red 8 LM2T SL1214 18.00<br />
Yellow 8 LM2T SL1215 18.00<br />
Blue 8 LM2T SL1216 18.00<br />
White 8 LM2T SL1218 18.00<br />
3 position (without mounting adapter).<br />
Green 8 LM2T SL1303 15.00<br />
Red 8 LM2T SL1304 15.00<br />
Yellow 8 LM2T SL1305 15.00<br />
Blue 8 LM2T SL1306 15.00<br />
White 8 LM2T SL1308 15.00<br />
Green 8 LM2T SL1313 18.00<br />
Red 8 LM2T SL1314 18.00<br />
Yellow 8 LM2T SL1315 18.00<br />
Blue 8 LM2T SL1316 18.00<br />
White 8 LM2T SL1318 18.00<br />
Green 8 LM2T SL1323 18.00<br />
Red 8 LM2T SL1324 18.00<br />
Yellow 8 LM2T SL1325 18.00<br />
Blue 8 LM2T SL1326 18.00<br />
White 8 LM2T SL1328 18.00<br />
Green 8 LM2T SL1333 18.00<br />
Red 8 LM2T SL1334 18.00<br />
Yellow 8 LM2T SL1335 18.00<br />
Blue 8 LM2T SL1336 18.00<br />
White 8 LM2T SL1338 18.00<br />
Operational characteristics<br />
– Ambient conditions:<br />
• Operating temperature: -13...+140°F (-25...+60°C)<br />
• Storage temperature: -40...+158°F (-40...+70°C)<br />
– Any mounting position is allowed<br />
– Degree of protection: IP40 for touch operators; IP65<br />
for selectors.<br />
Materials<br />
An aluminum and zinc alloy (zama) is used for the metal<br />
part whereas plastic parts are made of polyamide and<br />
polycarbonate.<br />
Mechanical endurance<br />
Mechanical life: 300,000 cycles for selectors;<br />
1,000,000 cycles for touch operators.<br />
Mounting adapter<br />
See page 7-17.<br />
Catalog number: 8 LM2T AU120.<br />
Operators latch onto the mounting adapter with a simple<br />
rotation.<br />
The adapter is fixed to the mounting surface by means of<br />
incorporated screws (Tmax = 7.1lbin / 0.8 Nm).<br />
Contact elements<br />
See page 7-17.<br />
Catalog numbers:<br />
8 LM2T C10 (1NO)<br />
8 LM2T CF10 (1NO Faston)<br />
8 LM2T C10A (EM)<br />
8 LM2T C01 (1NC)<br />
8 LM2T CF01 (1NC Faston)<br />
8 LM2T C01D (LB)<br />
Contact elements snap onto the mounting adapter.<br />
DOUBLE-TOUCH OPERATORS<br />
– Up to 4 contacts can be fitted on the mounting<br />
adapter, 2 each on the left and right, when one of the<br />
following lamp-holders is used: LM2T DL400,<br />
LM2T VL230, LM2T EL400, LM2T ZL230, LM2T L or<br />
LM2T M (see page 7-18).<br />
SELECTOR OPERATORS<br />
On 2-position illuminated selectors, the following can be<br />
fitted on the mounting adapter:<br />
– Up to 4 contacts, 2 each on the left and right, when<br />
one of the following lamp-holders is used:<br />
LM2T DL400, LM2T VL230, LM2T EL400,<br />
LM2T ZL230, LM2T L or LM2T M (see page 7-18).<br />
– Up to 2 contacts, 2 each on the left and right, when<br />
one of the following lamp-holders is used: LM2T XL,<br />
LM2T YL, LM2T FL or LM2T GL (see page 7-18).<br />
On 3-position illuminated selectors, the following can be<br />
fitted on the mounting adapter:<br />
– Up to 4 contacts, 2 each on the left and right, when<br />
one of the following lamp-holders is used:<br />
LM2T DL400, LM2T VL230, LM2T EL400,<br />
LM2T ZL230, LM2T L or LM2T M (see page 7-18).<br />
– NOTE: The following lamp-holders cannot be used:<br />
LM2T XL, LM2T YL, LM2T FL or LM2T GL.<br />
Selector positions<br />
Maintained position.<br />
Spring return position.<br />
Selector angles<br />
2 position 3 position<br />
90°<br />
Lamp-holder elements<br />
See page 7-18.<br />
45°<br />
45°<br />
Bulbs<br />
Maximum recommended power: 1.2W.<br />
See page 7-20.<br />
Certifications and compliance<br />
UL listed for USA and Canada, file E93601.<br />
Compliant with standards: IEC/EN 60947-1, IEC/EN 60947-5-1.<br />
7<br />
Add-on blocks<br />
pages 7-17 and 18<br />
Accessories and spare parts<br />
pages 7-19 to 21<br />
Dimensions<br />
page D-19<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com
7-8<br />
Push buttons and pilot devices, 22mm<br />
Metal series<br />
electric<br />
7<br />
Pilot light head Color Catalog number Price<br />
$ each<br />
8 LM2T IL103<br />
Without mounting adapter.<br />
Green 8 LM2T IL103 5.00<br />
Red 8 LM2T IL104 5.00<br />
Yellow 8 LM2T IL105 5.00<br />
Blue 8 LM2T IL106 5.00<br />
Transparent 8 LM2T IL107 5.00<br />
White 8 LM2T IL108 5.00<br />
Transparent ❶ 8 LM2T IL1187 6.50<br />
❶ With inscription indicating dangerous voltage (IEC 60417 5036-a).<br />
LM2T AU120❸<br />
LM2T AU160❸<br />
LM2T AL...❸<br />
LM2T A160❸<br />
LM2T DL400❷<br />
LM2T FL...❷<br />
LM2T GL... LM2T A190<br />
LM2T EL400<br />
LM2T AT...❸<br />
LM2T VL230❷<br />
LM2T ZL230<br />
LM2T T100<br />
LM2T YL...<br />
LM2T XL...❷<br />
LM2T L...<br />
LM2T M...<br />
❷ The mounting adapter is standard supplied so there is no need to purchase it<br />
as a separate accessory.<br />
❸ Can be purchased separately. Refer to pages 7-20 and 21.<br />
Operational characteristics<br />
– Ambient conditions:<br />
• Operating temperature: -13...+140°F (-25...+60°C)<br />
• Storage temperature: -40...+158°F (-40...+70°C)<br />
– Any mounting position is allowed<br />
– Degree of protection: IP65.<br />
Materials<br />
An aluminum and zinc alloy (zama) is used for the metal<br />
part whereas plastic parts are made of polyamide and<br />
polycarbonate.<br />
Mounting adapter<br />
See page 7-17.<br />
Catalog number: 8 LM2T AU120.<br />
Operators latch onto the mounting adapter with a simple<br />
rotation.<br />
The adapter is fixed to the mounting surface by means of<br />
incorporated screws (Tmax = 7.1lbin / 0.8 Nm).<br />
Lamp-holder elements<br />
See page 7-18.<br />
Bulbs<br />
Maximum recommended power: 1.2W.<br />
See page 7-20.<br />
Certifications and compliance<br />
UL listed for USA and Canada, file E93601.<br />
Compliant with standards: IEC/EN 60947-1, IEC/EN 60947-5-1.<br />
Potentiometer<br />
drive<br />
8 LM2T P100<br />
(complete with mounting adapter)<br />
8 LM2T P110<br />
(complete with mounting adapter)<br />
Inscription Catalog number Price<br />
$ each<br />
Graduated scale 8 LM2T P100❶ 45.40<br />
Variable index 8 LM2T P110❶ 45.40<br />
❶ Potentiometer not included, for assembly by the user.<br />
Operational characteristics<br />
– Suitable for potentiometers with 1 /4in (6-6.3mm)<br />
diameter shaft<br />
– Minimum 1 1 /2in (40mm) shaft length<br />
– Ambient conditions:<br />
• Operating temperature: -13...+140°F (-25...+60°C)<br />
• Storage temperature: -40...+158°F (-40...+70°C)<br />
– Any mounting position is allowed<br />
– Degree of protection: IP65 (warranted by potentiometers<br />
with a cylindrical shaft).<br />
Materials<br />
An aluminum and zinc alloy (zama) is used for the metal<br />
part whereas plastic parts are made of polyamide and<br />
polycarbonate.<br />
Mechanical endurance<br />
Mechanical life: 300,000 cycles.<br />
Mounting adapter<br />
Standard supply with operator.<br />
Operators latch onto the mounting adapter with a simple<br />
rotation.<br />
The adapter is fixed to the mounting surface by means of<br />
incorporated screws (Tmax = 7.1lbin / 0.8 Nm).<br />
Add-on blocks<br />
pages 7-17 and 18<br />
Accessories and spare parts<br />
pages 7-19 to 21<br />
Dimensions<br />
page D-19<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com
electric<br />
Push buttons and pilot devices, 22mm<br />
Metal series<br />
7-9<br />
Joysticks<br />
Type of Number of Catalog number Price<br />
positions elements $ each<br />
Without mechanical interlock. Label holder excluded.<br />
Complete with auxiliary contacts.<br />
2 8 LM2T J200 51.00<br />
Operational characteristics<br />
– Ambient conditions:<br />
• Operating temperature: -13...+140°F (-25...+60°C)<br />
• Storage temperature: -40...+158°F (-40...+70°C)<br />
– Any mounting position is allowed<br />
– Degree of protection: IP65.<br />
2 8 LM2T J201 51.00<br />
Materials<br />
An aluminum and zinc alloy (zama) is used for the metal<br />
parts whereas plastic parts are made of polyamide and<br />
polycarbonate.<br />
The sealing boot is made of NBR rubber.<br />
4 8 LM2T J400 62.00<br />
Mechanical endurance<br />
Mechanical life: 1,000,000 cycles<br />
8 LM2T J200<br />
without mechanical interlock<br />
4 8 LM2T J401 62.00<br />
With mechanical interlock in center position.<br />
Label holder excluded.<br />
Complete with auxiliary contacts.<br />
2 8 LM2T J210 58.00<br />
2 8 LM2T J211 58.00<br />
Mounting adapter and contact elements<br />
The joystick is standard supplied with the mounting<br />
adapter and contacts.<br />
The joystick latches onto the mounting adapter with a<br />
simple rotation.<br />
The adapter is fixed to the mounting surface by means<br />
of incorporated screws (Tmax = 7.1lbin / 0.8Nm).<br />
Contacts snap onto the mounting adapter.<br />
Two LM2T CJ contacts are mounted with the LM2T J2<br />
types while four on the LM2T J4 versions.<br />
Terminal tightening torque: 8.8lbin / 1Nm.<br />
UL designation: A/300, Q/300.<br />
7<br />
4 8 LM2T J410 70.00<br />
1<br />
4 8 LM2T J411 70.00<br />
2<br />
8 LM2T J410<br />
with mechanical interlock<br />
Joystick positions and contact engerizing<br />
2 instable 2 maintained 4 instable 4 maintained<br />
Accessories<br />
Description Catalog number Price<br />
$ each<br />
2-4 directional holder 8 LM2T AU101 4.00<br />
for adhesive legends<br />
1<br />
2<br />
A<br />
LM2TCJ10<br />
A B<br />
1 ●<br />
2 ●<br />
8 LM2T AU101<br />
B<br />
2<br />
4<br />
3<br />
A B C D<br />
LM2TCJ10 1 ●<br />
LM2TCJ01 2 ●<br />
LM2TCJ10 3 ●<br />
LM2TCJ01 4 ●<br />
A<br />
1<br />
D<br />
C<br />
B<br />
Certifications and compliance<br />
UL listed for USA and Canada, file E93601.<br />
Compliant with standards: IEC/EN 60947-1, IEC/EN 60947-5-1.<br />
Accessories<br />
page 7-19<br />
Dimensions<br />
page D-20<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com
7-10<br />
Push buttons and pilot devices, 22mm<br />
Plastic series<br />
electric<br />
7<br />
Push-button<br />
operators,<br />
momentary<br />
8 LP2T B104<br />
8 LP2T B204<br />
8 LP2T B303<br />
Color Catalog number Price<br />
$ each<br />
Flush (complete with mounting adapter), momentary.<br />
Black 8 LP2T B102 7.50<br />
Green 8 LP2T B103 7.50<br />
Red 8 LP2T B104 7.50<br />
Yellow 8 LP2T B105 7.50<br />
Blue 8 LP2T B106 7.50<br />
White 8 LP2T B108 7.50<br />
Extended (complete with mounting adapter), momentary.<br />
Black 8 LP2T B202 8.00<br />
Green 8 LP2T B203 8.00<br />
Red 8 LP2T B204 8.00<br />
Yellow 8 LP2T B205 8.00<br />
Blue 8 LP2T B206 8.00<br />
White 8 LP2T B208 8.00<br />
Guarded (complete with mounting adapter), momentary.<br />
Black 8 LP2T B302 13.00<br />
Green 8 LP2T B303 13.00<br />
Red 8 LP2T B304 13.00<br />
Yellow 8 LP2T B305 13.00<br />
Blue 8 LP2T B306 13.00<br />
White 8 LP2T B308 13.00<br />
Operational characteristics<br />
– Ambient conditions:<br />
• Operating temperature: -13...+140°F (-25...+60°C)<br />
• Storage temperature: -40...+158°F (-40...+70°C)<br />
– Any mounting position is allowed<br />
– Degree of protection: IP65.<br />
Materials<br />
Polyamide and polycarbonate.<br />
Mechanical endurance<br />
Operating force: 1.76lb / 0.8 kg (operator).<br />
Mechanical life: 1,000,000 cycles.<br />
Mounting adapter<br />
Standard supply with the operator.<br />
Operators latch onto the mounting adapter with a simple<br />
rotation.<br />
The adapter is fixed to the mounting surface by means of<br />
incorporated screws (Tmax = 5.3lbin / 0.6 Nm).<br />
Contact elements<br />
See page 7-17.<br />
Catalog numbers: 8 LM2T C10 (1NO)<br />
8 LM2T CF10 (1NO Faston)<br />
8 LM2T C10A (EM)<br />
8 LM2T C01 (1NC)<br />
8 LM2T CF01 (1NC Faston)<br />
8 LM2T C01D (LB)<br />
Contact elements snap onto the mounting adapter.<br />
Up to 6 contacts can be fitted on the mounting adapter: 2<br />
on the left, 2 at the center and 2 on the right.<br />
To mount the auxiliary contacts in the center position, use<br />
the accessory: LM2T A140 (see page 7-21).<br />
Push-button<br />
operators,<br />
momentary, with<br />
inscription<br />
8 LP2T B1104<br />
8 LP2T B2104<br />
Inscription Color Catalog number Price<br />
$ each<br />
Flush (complete with mounting adapter), momentary.<br />
O Black 8 LP2T B1102 9.00<br />
Red 8 LP2T B1104 9.00<br />
I Green 8 LP2T B1113 9.00<br />
White 8 LP2T B1118 9.00<br />
II Green 8 LP2T B1123 9.00<br />
White 8 LP2T B1128 9.00<br />
STOP Black 8 LP2T B1132 9.00<br />
Red 8 LP2T B1134 9.00<br />
❶<br />
Black 8 LP2T B1142 9.00<br />
White 8 LP2T B1148 9.00<br />
❷<br />
Black 8 LP2T B1152 9.00<br />
White 8 LP2T B1158 9.00<br />
START Green 8 LP2T B1163 9.00<br />
White 8 LP2T B1168 9.00<br />
R Blue 8 LP2T B1176 9.00<br />
White 8 LP2T B1178 9.00<br />
RESET Blue 8 LP2T B1196 9.00<br />
Black 8 LP2T B1502 9.00<br />
Black 8 LP2T B1512 9.00<br />
Extended (complete with mounting adapter), momentary.<br />
O Black 8 LP2T B2102 10.50<br />
Red 8 LP2T B2104 10.50<br />
STOP Black 8 LP2T B2132 10.50<br />
Red 8 LP2T B2134 10.50<br />
❶ Arrow inscription can be used to indicate right or left.<br />
❷ Arrow inscription can be used to indicate up or down.<br />
CLICK<br />
LM2T A140❸<br />
❸ The action plug LM2T A140 for the center position is not standard<br />
supplied and must be purchased separately.<br />
Certifications and compliance<br />
UL listed for USA and Canada, file E93601.<br />
Compliant with standards: IEC/EN 60947-1, IEC/EN 60947-5-1.<br />
Add-on blocks<br />
pages 7-17 and 18<br />
Accessories and spare parts<br />
pages 7-19 to 21<br />
Dimensions<br />
page D-19<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com
electric<br />
Push buttons and pilot devices, 22mm<br />
Plastic series<br />
7-11<br />
Push-push button<br />
operators<br />
8 LP2T Q10<br />
8 LP2T Q20<br />
Mushroom head<br />
button operators<br />
8 LP2T B614<br />
8 LP2T B616<br />
8 LP2T B624<br />
8 LP2T B634<br />
Color Catalog number Price<br />
$ each<br />
Flush (complete with mounting adapter).<br />
Maintained, push to release.<br />
Black 8 LP2T Q102❶ 21.50<br />
Green 8 LP2T Q103❶ 21.50<br />
Red 8 LP2T Q104❶ 21.50<br />
Yellow 8 LP2T Q105❶ 21.50<br />
Blue 8 LP2T Q106❶ 21.50<br />
White 8 LP2T Q108❶ 21.50<br />
Extended (complete with mounting adapter).<br />
Maintained, push to release.<br />
Black 8 LP2T Q202❶ 23.50<br />
Green 8 LP2T Q203❶ 23.50<br />
Red 8 LP2T Q204❶ 23.50<br />
Yellow 8 LP2T Q205❶ 23.50<br />
Blue 8 LP2T Q206❶ 23.50<br />
White 8 LP2T Q208❶ 23.50<br />
❶ Use the early-make type, LM2T C10A only.<br />
No normally open contact element, LM2T C10, must be used with this type of<br />
button operators.<br />
A maximum of 2 contact elements can be mounted only.<br />
Color Catalog number Price<br />
$ each<br />
Momentary. Ø 40 mm (1.6in)<br />
(complete with mounting adapter).<br />
Black 8 LP2T B6142 14.00<br />
Green 8 LP2T B6143 14.00<br />
Red 8 LP2T B6144 14.00<br />
Yellow 8 LP2T B6145 14.00<br />
Blue 8 LP2T B6146 14.00<br />
Momentary. Ø 60 mm (2.4in)<br />
(complete with mounting adapter).<br />
Black 8 LP2T B6162 17.00<br />
Green 8 LP2T B6163 17.00<br />
Red 8 LP2T B6164 17.00<br />
Yellow 8 LP2T B6165 17.00<br />
Blue 8 LP2T B6166 17.00<br />
Maintained, pull to release. Ø 40 mm (1.6in)<br />
(complete with mounting adapter).<br />
Black 8 LP2T B6242 22.00<br />
Red 8 LP2T B6244 22.00<br />
Maintained, twist to release. Ø 40 mm (1.6in)<br />
(complete with mounting adapter).<br />
Black 8 LP2T B6342 24.00<br />
Red 8 LP2T B6344 24.00<br />
Maintained, twist key to release. Ø 40 mm (1.6in), keyed<br />
(complete with mounting adapter).<br />
Black 8 LP2T B6542 45.00<br />
8 LP2T B6542G...❶ 47.00<br />
Red 8 LP2T B6544 45.00<br />
8 LP2T B6544G...❶ 47.00<br />
Maintained, twist to release, mechanical latching EN418<br />
compliant Ø 40 mm (1.6in) (complete with mounting adapter).<br />
Red 8 LP2T B6644 40.00<br />
Operational characteristics<br />
– Ambient conditions:<br />
• Operating temperature: -13...+140°F (-25...+60°C)<br />
• Storage temperature: -40...+158°F (-40...+70°C)<br />
– Any mounting position is allowed.<br />
– Degree of protection: IP65 for push-push and<br />
LP2T B654 operators; IP66 for others.<br />
Materials<br />
Polyamide and polycarbonate.<br />
Mechanical endurance<br />
Operating force: 1.76lb / 0.8 kg (operator).<br />
Mechanical life:<br />
– Push-push operators: 500,000 cycles<br />
– Mushroom-head latch operators: 300,000 cycles<br />
– All others: 1,000,000 cycles.<br />
Mounting adapter<br />
Standard supply with the operator.<br />
Operators latch onto the mounting adapter with a simple<br />
rotation.<br />
The adapter is fixed to the mounting surface by means of<br />
incorporated screws (Tmax = 5.3lbin / 0.6 Nm).<br />
Contact elements for push-push button actuators<br />
See page 7-17.<br />
Catalog number:<br />
CLICK<br />
8 LM2T C10A (EM)<br />
8 LM2T C01 (1NC)<br />
Contact elements snap onto the mounting adapter.<br />
Up to 2 contacts can be fitted on the mounting adapter:<br />
1 each on the right and left.<br />
Contact elements for mushroom-head operators<br />
See page 7-17.<br />
Catalog numbers: 8 LM2T C10 (1NO)<br />
8 LM2T CF10 (1NO Faston)<br />
8 LM2T C10A (EM)<br />
8 LM2T C01 (1NC)<br />
8 LM2T CF01 (1NC Faston)<br />
8 LM2T C01D (LB)<br />
Contact elements snap onto the mounting adapter<br />
Up to 4 contacts can be fitted on the mounting adapter<br />
with the LP2T B624... and LP2T B6644 types.<br />
Up to 6 contacts can be fitted on the mounting adapter with<br />
all the rest: 2 on the left, 2 at the center and 2 on the right.<br />
To mount the auxiliary contacts in the center position with<br />
LP2T B614... and LP2T B616... types only, use the action<br />
plug LM2T A140 (see page 7-21).<br />
LM2T A140❸<br />
7<br />
8 LP2T B654<br />
❶ Versions with different key codes.<br />
Complete with the numeric code of the key. The following versions are available:<br />
501, 502, 503, 504, 505, 506, 507, 508, 509, 510.<br />
Example of complete catalog number: 8 LM2T B6542G505.<br />
❸ The action plug LM2T A140 for the center position is not standard<br />
supplied and must be purchased separately.<br />
Certifications and compliance<br />
UL listed for USA and Canada, file E93601.<br />
Compliant with standards: IEC/EN 60947-1, IEC/EN 60947-5-1.<br />
8 LP2T B6644<br />
Add-on blocks<br />
pages 7-17 and 18<br />
Accessories and spare parts<br />
pages 7-19 to 21<br />
Dimensions<br />
pages D-19<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com
7-12<br />
Push buttons and pilot devices, 22mm<br />
Plastic series<br />
electric<br />
7<br />
Mechanical reset<br />
buttons, complete<br />
unit, momentary<br />
8 LP2T R1196<br />
(complete with mounting adapter and rod)<br />
Double-touch<br />
operators,<br />
momentary<br />
8 LP2T B7113<br />
8 LP2T B7223<br />
Color Catalog number Price<br />
$ each<br />
Flush (0.2in / 5.2 mm stroke). Adjustable length 0-5in (0-123 mm).<br />
Black 8 LP2T R1002 10.00<br />
Green 8 LP2T R1003 10.00<br />
Red 8 LP2T R1004 10.00<br />
Yellow 8 LP2T R1005 10.00<br />
Blue 8 LP2T R1006 10.00<br />
Blue (RESET) 8 LP2T R1196❷ 12.00<br />
Extended (0.2in /5.2 mm stroke). Adjustable length 0-5in (0-123 mm).<br />
Red 8 LP2T R2004 12.00<br />
❷ With “RESET” inscription on the operator.<br />
Colors Marked Catalog Price<br />
in white number $ each<br />
Two flush push-buttons (complete with mounting adapter).<br />
Both momentary.<br />
Black/Red –– 8 LP2T B7112 10.00<br />
Green/Red –– 8 LP2T B7113 10.00<br />
White/Black –– 8 LP2T B7114 10.00<br />
Black/Red I-O 8 LP2T B7122 11.00<br />
Green/Red I-O 8 LP2T B7123 11.00<br />
White/Black I-O 8 LP2T B7124 11.00<br />
Green/Red Start/Stop 8 LP2T B7133 11.00<br />
One extended and one flush button (c/w mounting adapter).<br />
Both momentary.<br />
Black/Red –– 8 LP2T B7212 10.00<br />
Green/Red –– 8 LP2T B7213 10.00<br />
White/Black –– 8 LP2T B7214 10.00<br />
Black/Red I-O 8 LP2T B7222 11.00<br />
Green/Red I-O 8 LP2T B7223 11.00<br />
White/Black I-O 8 LP2T B7224 11.00<br />
Green/Red Start/Stop 8 LP2T B7233 11.00<br />
Operational characteristics<br />
– Ambient conditions:<br />
• Operating temperature: -13...+140°F (-25...+60°C)<br />
• Storage temperature: -40...+158°F (-40...+70°C)<br />
– Any mounting position is allowed.<br />
– Degree of protection: IP65 for mechanical reset buttons<br />
and IP40 for double and triple touch operators.<br />
Materials<br />
Polyamide and polycarbonate.<br />
Mechanical endurance<br />
Operating force: 1.76lb / 0.8 kg (operator).<br />
Mechanical life: 1,000,000 cycles.<br />
Mounting adapter<br />
Standard supply with the operator.<br />
Operators latch onto the mounting adapter with a simple<br />
rotation.<br />
The adapter is fixed to the mounting surface by means of<br />
incorporated screws (Tmax = 5.3lbin / 0.6 Nm).<br />
Contact elements for touch operators<br />
See page 7-17.<br />
Catalog numbers: 8 LM2T C10 (1NO)<br />
8 LM2T CF10 (1NO Faston)<br />
8 LM2T C10A (EM)<br />
8 LM2T C01 (1NC)<br />
8 LM2T CF01 (1NC Faston)<br />
8 LM2T C01D (LB)<br />
Contact elements snap onto the mounting adapter.<br />
DOUBLE-TOUCH OPERATORS<br />
Up to 4 auxiliary contacts can be fitted on the mounting<br />
adapter: 2 on the left and 2 on the right.<br />
TRIPLE-TOUCH OPERATORS<br />
Up to 6 auxiliary contacts can be fitted on the mounting<br />
adapter: 2 on the left, 2 in the center and 2 on the right.<br />
Triple-touch<br />
operators,<br />
momentary<br />
Colors Marked Catalog Price<br />
in white number $ each<br />
Two external flush and one middle extended buttons.<br />
Complete with mounting adapter. All momentary.<br />
Green 8 LP2T B7345 14.00<br />
Red<br />
Green<br />
STOP<br />
Certifications and compliance<br />
UL listed for USA and Canada, file E93601.<br />
Compliant with standards: IEC/EN 60947-1, IEC/EN 60947-5-1.<br />
8 LP2T B7355<br />
Green 8 LP2T B7355 14.00<br />
Red<br />
Green<br />
STOP<br />
Green 8 LP2T B7365 14.00<br />
Red<br />
Green<br />
STOP<br />
Green 8 LP2T B7375 14.00<br />
Red<br />
Green<br />
STOP<br />
Add-on blocks<br />
pages 7-17 and 18<br />
Accessories and spare parts<br />
pages 7-19 to 21<br />
Dimensions<br />
page D-19<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com
electric<br />
Push buttons and pilot devices, 22mm<br />
Plastic series<br />
7-13<br />
Selector switch<br />
operators, knob<br />
8 LP2T S120<br />
Selector switch<br />
operators, lever<br />
8 LP2T S230<br />
Selector switch<br />
operators, key<br />
Type of Catalog number Price<br />
positions<br />
$ each<br />
2 position (complete with mounting adapter).<br />
8 LP2T S120 14.00<br />
8 LP2T S121 16.00<br />
3 position (complete with mounting adapter).<br />
8 LP2T S130 14.00<br />
8 LP2T S131 16.00<br />
8 LP2T S132 16.00<br />
8 LP2T S133 16.00<br />
Type of Catalog number Price<br />
positions<br />
$ each<br />
2 position (complete with mounting adapter).<br />
8 LP2T S220 14.00<br />
8 LP2T S221 16.00<br />
3 position (complete with mounting adapter).<br />
8 LP2T S230 14.00<br />
8 LP2T S231 16.00<br />
8 LP2T S232 16.00<br />
8 LP2T S233 16.00<br />
Type of Catalog number Price<br />
positions<br />
$ each<br />
2 position (complete with mounting adapter).<br />
8 LP2T S320 35.00<br />
8 LP2T S320G...❶ 38.00<br />
8 LP2T S321 35.00<br />
8 LP2T S321G...❶ 38.00<br />
8 LP2T S340 36.00<br />
8 LP2T S340G...❶ 39.00<br />
3 position (complete with mounting adapter).<br />
8 LP2T S330 35.00<br />
8 LP2T S330G...❶ 38.00<br />
8 LP2T S331 35.00<br />
8 LP2T S331G...❶ 38.00<br />
8 LP2T S332❷ 35.00<br />
8 LP2T S332G...❶❷ 38.00<br />
8 LP2T S333❷ 35.00<br />
8 LP2T S333G...❶❷ 38.00<br />
8 LP2T S350 36.00<br />
8 LP2T S350G...❶ 40.00<br />
8 LP2T S360 36.00<br />
8 LP2T S360G...❶ 40.00<br />
8 LP2T S370❷ 36.00<br />
8 LP2T S370G...❶❷ 40.00<br />
8 LP2T S380❷ 36.00<br />
8 LP2T S380G...❶❷ 40.00<br />
8 LP2T S390❷ 36.00<br />
8 LP2T S390G...❶❷ 40.00<br />
Operational characteristics<br />
– Ambient conditions:<br />
• Operating temperature: -13...+140°F (-25...+60°C)<br />
• Storage temperature: -40...+158°F (-40...+70°C)<br />
– Any mounting position is allowed<br />
– Degree of protection: IP65.<br />
Materials<br />
Polyamide and polycarbonate.<br />
Mechanical endurance<br />
Mechanical life: 300,000 cycles.<br />
Mounting adapter<br />
Standard supply with the operator.<br />
Operators latch onto the mounting adapter with a simple<br />
rotation.<br />
The adapter is fixed to the mounting surface by means of<br />
incorporated screws (Tmax = 5.3lbin / 0.6 Nm).<br />
Contact elements<br />
See page 7-17.<br />
Contact elements snap onto the mounting adapter.<br />
Catalog numbers: 8 LM2T C10 (1NO)<br />
8 LM2T CF10 (1NO Faston)<br />
8 LM2T C10A (EM)<br />
8 LM2T C01 (1NC)<br />
8 LM2T CF01 (1NC Faston)<br />
8 LM2T C01D (LB)<br />
Up to 4 contacts can be fitted on the mounting adapter:<br />
2 on the left and 2 on the right. For more, contact Sales &<br />
Technical Support.<br />
Positions<br />
8 LP2T S330 Maintained position.<br />
Spring return position.<br />
Key withdrawal position.<br />
Angles<br />
2 position 3 position<br />
90°<br />
Special versions<br />
Versions with colored keys are available upon request.<br />
Contact Sales & Technical Support.<br />
Certifications and compliance<br />
UL listed for USA and Canada, file E93601.<br />
Compliant with standards: IEC/EN 60947-1, IEC/EN 60947-5-1.<br />
45°<br />
45°<br />
7<br />
❶ Versions with different key codes.<br />
Complete with the numeric code of the key. The following versions are available:<br />
501, 502, 503, 504, 505, 506, 507, 508, 509, 510.<br />
Example of complete catalog number: 8 LP2T S320G505.<br />
❷ Available only on specific request.<br />
Add-on blocks<br />
pages 7-17 and 18<br />
Accessories and spare parts<br />
pages 7-19 to 21<br />
Dimensions<br />
page D-19<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com
7-14<br />
Push buttons and pilot devices, 22mm<br />
Plastic series<br />
electric<br />
7<br />
Illuminated button<br />
operators<br />
8 LP2T BL104<br />
8 LP2T BL204<br />
Push-push button<br />
operators<br />
8 LP2T QL104<br />
8 LP2T QL204<br />
Illuminated<br />
mushroom head<br />
button operators<br />
8 LP2T BL6144<br />
Color Catalog number Price<br />
$ each<br />
Flush (with side visibility), momentary<br />
(complete with mounting adapter).<br />
Green 8 LP2T BL103 11.00<br />
Red 8 LP2T BL104 11.00<br />
Yellow 8 LP2T BL105 11.00<br />
Blue 8 LP2T BL106 11.00<br />
Transparent 8 LP2T BL107 11.00<br />
Extended (complete with mounting adapter), momentary.<br />
Green 8 LP2T BL203 12.00<br />
Red 8 LP2T BL204 12.00<br />
Yellow 8 LP2T BL205 12.00<br />
Blue 8 LP2T BL206 12.00<br />
Transparent 8 LP2T BL207 12.00<br />
Color Catalog number Price<br />
$ each<br />
Flush (complete with mounting adapter).<br />
Maintained, push to release.<br />
Green 8 LP2T QL103❶ 32.50<br />
Red 8 LP2T QL104❶ 32.50<br />
Yellow 8 LP2T QL105❶ 32.50<br />
Blue 8 LP2T QL106❶ 32.50<br />
Transparent 8 LP2T QL107❶ 32.50<br />
Extended (complete with mounting adapter).<br />
Maintained, push to release.<br />
Green 8 LP2T QL203❶ 38.50<br />
Red 8 LP2T QL204❶ 38.50<br />
Yellow 8 LP2T QL205❶ 38.50<br />
Blue 8 LP2T QL206❶ 38.50<br />
White 8 LP2T QL207❶ 38.50<br />
❶ Use the early-make type, LM2T C10A only.<br />
No normally open contact element, LM2T C10, must be used with this type of<br />
button operators.<br />
A maximum of 2 contact elements can be mounted only.<br />
Color Catalog number Price<br />
$ each<br />
Momentary. Ø 40mm (1.6in)<br />
(complete with mounting adapter)❷.<br />
Green 8 LP2T BL6143 18.00<br />
Red 8 LP2T BL6144 18.00<br />
Yellow 8 LP2T BL6145 18.00<br />
Blue 8 LP2T BL6146 18.00<br />
White 8 LP2T BL6148 18.00<br />
Maintained, pull to release. Ø 40mm (1.6in)<br />
(complete with mounting adapter)❷.<br />
Green 8 LP2T BL6243 37.50<br />
Red 8 LP2T BL6244 37.50<br />
Yellow 8 LP2T BL6245 37.50<br />
Blue 8 LP2T BL6246 37.50<br />
White 8 LP2T BL6248 37.50<br />
❷ The number of contact elements to be mounted is given in the side notes.<br />
Operational characteristics<br />
– Ambient conditions:<br />
• Operating temperature: -13...+140°F (-25...+60°C)<br />
• Storage temperature: -40...+158°F (-40...+70°C)<br />
– Any mounting position is allowed<br />
– Degree of protection: IP65.<br />
Materials<br />
Polyamide and polycarbonate.<br />
Mechanical endurance<br />
Operating force: 1.76lb / 0.8kg (operator).<br />
Mechanical life:<br />
– Push-push operators: 500,000 cycles<br />
– Mushroom head latch operators: 300,000 cycles<br />
– All others: 1,000,000 cycles.<br />
Mounting adapter<br />
Standard supply with the operator.<br />
Operators latch onto the mounting adapter with a simple<br />
rotation.<br />
The adapter is fixed to the mounting surface by means of<br />
incorporated screws (Tmax = 5.3lbin / 0.6 Nm).<br />
Contact elements for illuminated push-push operators:<br />
See page 7-17.<br />
Catalog number:<br />
8 LM2T C10A (EM)<br />
8 LM2T C01 (1NC)<br />
Contact elements snap onto the mounting adapter.<br />
Up to 2 contacts can be fitted on the mounting adapter<br />
in a row, 1 each on the right and left, along with the<br />
lamp-holder in the center position, of which<br />
LM2T EL400, LM2T ZL230, LM2T L... or LM2T M... (see<br />
page 7-18).<br />
With lamp-holder LM2T YL... or LM2T GL..., one<br />
auxiliary contact can be mounted only (see page 7-18).<br />
Contact elements for illuminated momentary button and<br />
mushroom-head operators:<br />
See page 7-17.<br />
Catalog numbers: 8 LM2T C10 (1NO)<br />
8 LM2T CF10 (1NO Faston)<br />
8 LM2T C10A (EM)<br />
8 LM2T C01 (1NC)<br />
8 LM2T CF01 (1NC Faston)<br />
8 LM2T C01D (LB)<br />
Contact elements snap onto the mounting adapter.<br />
On LP2T BL1, LP2T BL2 or LP2T BL61 operators, the<br />
following can be fitted on the mounting adapter:<br />
– Up to 4 contacts, 2 each on the left and right, when<br />
one of the following lamp-holders is used:<br />
LM2T DL400, LM2T EL400, LM2T VL230,<br />
LM2T ZL230, LM2T L or LM2T M (see page 7-18).<br />
– Up to 2 contacts, one on top of the other of the same<br />
type only, when one of the following lamp-holders is<br />
used LM2T XL, LM2T YL, LM2T FL or LM2T GL (see<br />
page 7-18).<br />
On LP2T BL62... operator, the following can be fitted on<br />
the mounting adapter:<br />
– Up to 2 contacts, 1 each on the right and left, when<br />
one of the following lamp-holders is used:<br />
LM2T DL400, LM2T EL400, LM2T VL230,<br />
LM2T ZL230, LM2T L or LM2T M (see page 7-18)<br />
– Up to 2 contacts, one on top of the other of the same<br />
type only, when one of the following lamp-holders is<br />
used: LM2T XL, LM2T YL, LM2T FL or LM2T GL (see<br />
page 7-18).<br />
8 LP2T BL6245<br />
Lamp-holder elements<br />
See pages 7-18.<br />
Bulbs<br />
Maximum recommended power: 1.2W. See page 7-20.<br />
Certifications and compliance<br />
UL listed for USA and Canada, file E93601.<br />
Compliant with standards: IEC/EN 60947-1, IEC/EN 60947-5-1.<br />
Add-on blocks<br />
pages 7-17 and 18<br />
Accessories and spare parts<br />
pages 7-19 to 21<br />
Dimensions<br />
page D-19<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com
electric<br />
Push buttons and pilot devices, 22mm<br />
Plastic series<br />
7-15<br />
Double-touch<br />
operators<br />
momentary, white<br />
indicator<br />
8 LP2T BL7113 8 LP2T BL7223<br />
Illuminated<br />
selector operators<br />
8 LP2T SL1205<br />
Color Marked Catalog Price<br />
in white number $ each<br />
Two flush push-buttons (complete with mounting adapter).<br />
Both momentary.<br />
Black/Red –– 8 LP2T BL7112 11.00<br />
Green/Red –– 8 LP2T BL7113 11.00<br />
White/Black –– 8 LP2T BL7114 11.00<br />
Black/Red I-O 8 LP2T BL7122 12.00<br />
Green/Red I-O 8 LP2T BL7123 12.00<br />
White/Black I-O 8 LP2T BL7124 12.00<br />
Green/Red Start/Stop 8 LP2T BL7133 12.00<br />
One extended and one flush button (c/w mounting adapter).<br />
Both momentary.<br />
Black/Red –– 8 LP2T BL7212 11.00<br />
Green/Red –– 8 LP2T BL7213 11.00<br />
White/Black –– 8 LP2T BL7214 11.00<br />
Black/Red I-O 8 LP2T BL7222 12.00<br />
Green/Red I-O 8 LP2T BL7223 12.00<br />
White/Black I-O 8 LP2T BL7224 12.00<br />
Green/Red Start/Stop 8 LP2T BL7233 12.00<br />
Color Type of Catalog number Price<br />
positions<br />
$ each<br />
2 position (complete with mounting adapter).<br />
Green 8 LP2T SL1203 16.00<br />
Red 8 LP2T SL1204 16.00<br />
Yellow 8 LP2T SL1205 16.00<br />
Blue 8 LP2T SL1206 16.00<br />
White 8 LP2T SL1208 16.00<br />
Green 8 LP2T SL1213 17.00<br />
Red 8 LP2T SL1214 17.00<br />
Yellow 8 LP2T SL1215 17.00<br />
Blue 8 LP2T SL1216 17.00<br />
White 8 LP2T SL1218 17.00<br />
3 position (complete with mounting adapter).<br />
Green 8 LP2T SL1303 16.00<br />
Red 8 LP2T SL1304 16.00<br />
Yellow 8 LP2T SL1305 16.00<br />
Blue 8 LP2T SL1306 16.00<br />
White 8 LP2T SL1308 16.00<br />
Green 8 LP2T SL1313 17.00<br />
Red 8 LP2T SL1314 17.00<br />
Yellow 8 LP2T SL1315 17.00<br />
Blue 8 LP2T SL1316 17.00<br />
White 8 LP2T SL1318 17.00<br />
Green 8 LP2T SL1323 17.00<br />
Red 8 LP2T SL1324 17.00<br />
Yellow 8 LP2T SL1325 17.00<br />
Blue 8 LP2T SL1326 17.00<br />
White 8 LP2T SL1328 17.00<br />
Green 8 LP2T SL1333 17.00<br />
Red 8 LP2T SL1334 17.00<br />
Yellow 8 LP2T SL1335 17.00<br />
Blue 8 LP2T SL1336 17.00<br />
White 8 LP2T SL1338 17.00<br />
Operational characteristics<br />
– Ambient conditions:<br />
• Operating temperature: -13...+140°F (-25...+60°C)<br />
• Storage temperature: -40...+158°F (-40...+70°C)<br />
– Any mounting position is allowed<br />
– Degree of protection: IP40 for touch operators;<br />
IP65 for selector operators.<br />
Materials<br />
Polyamide and polycarbonate.<br />
Mechanical endurance<br />
Operating force: 1.76lb / 0.8kg (operator).<br />
Mechanical life for 1,000,000 cycles touch-buttons; 300,000<br />
cycles for selectors.<br />
Mounting adapter<br />
Standard supply with the operartor.<br />
Operators latch onto the mounting adapter with a simple<br />
rotation.<br />
The adapter is fixed to the mounting surface by means of<br />
incorporated screws (Tmax = 5.3lbin / 0.6 Nm).<br />
Contact elements for button operators<br />
See page 7-17.<br />
Catalog numbers:<br />
8 LM2T C10 (1NO)<br />
8 LM2T CF10 (1NO Faston)<br />
8 LM2T C10A (EM)<br />
8 LM2T C01 (1NC)<br />
8 LM2T CF01 (1NC Faston)<br />
8 LM2T C01D (LB)<br />
Contact elements snap onto the mounting adapter.<br />
DOUBLE-TOUCH OPERATORS<br />
– Up to 4 contacts can be fitted on the mounting<br />
adapter, 2 each on the left and right, when one of the<br />
following lamp-holders is used: LM2T DL400,<br />
LM2T VL230, LM2T EL400, LM2T ZL230, LM2T L or<br />
LM2T M (see page 7-18).<br />
SELECTOR OPERATORS<br />
On 2-position illuminated selectors, the following can be<br />
fitted on the mounting adapter:<br />
– Up to 4 contacts, 2 each on the left and right, when<br />
one of the following lamp-holders is used:<br />
LM2T DL400, LM2T VL230, LM2T EL400,<br />
LM2T ZL230, LM2T L or LM2T M (see page 7-18).<br />
– Up to 2 contacts, 2 each on the left and right, when<br />
one of the following lamp-holders is used: LM2T XL,<br />
LM2T YL, LM2T FL or LM2T GL (see page 7-18).<br />
On 3-position illuminated selectors, the following can be<br />
fitted on the mounting adapter:<br />
– Up to 4 contacts, 2 each on the left and right, when<br />
one of the following lamp-holders is used:<br />
LM2T DL400, LM2T VL230, LM2T EL400,<br />
LM2T ZL230, LM2T L or LM2T M (see page 7-18).<br />
– NOTE: The following lamp-holders cannot be used:<br />
LM2T XL, LM2T YL, LM2T FL or LM2T GL.<br />
Selector positions<br />
Maintained position.<br />
Spring return position.<br />
Selector angles<br />
2 position 3 position<br />
90°<br />
Lamp-holder elements<br />
See page 7-18.<br />
45°<br />
Bulbs<br />
Maximum recommended power: 1.2W.<br />
See page 7-20.<br />
45°<br />
7<br />
Certifications and compliance<br />
UL listed for USA and Canada, file E93601.<br />
Compliant with standards: IEC/EN 60947-1, IEC/EN 60947-5-1.<br />
Add-on blocks<br />
pages 7-17 and 18<br />
Accessories and spare parts<br />
pages 7-19 to 21<br />
Dimensions<br />
page D-19<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com
7-16<br />
Push buttons and pilot devices, 22mm<br />
Pilot lights - Empty control stations<br />
electric<br />
LED integrated<br />
monoblock pilot<br />
lights, steady light<br />
8 LP2T ILB3<br />
Voltage LED Catalog Price<br />
color number $ each<br />
12VAC/DC Green 8 LP2T ILA3 12.00<br />
Red 8 LP2T ILA4 12.00<br />
Yellow 8 LP2T ILA5 12.00<br />
Blue 8 LP2T ILA6 12.00<br />
Transparent 8 LP2T ILA8 12.00<br />
24VAC/DC Green 8 LP2T ILB3 12.00<br />
Red 8 LP2T ILB4 12.00<br />
Yellow 8 LP2T ILB5 12.00<br />
Blue 8 LP2T ILB6 12.00<br />
Transparent 8 LP2T ILB8 12.00<br />
110VAC Green 8 LP2T ILE3 14.00<br />
Red 8 LP2T ILE4 14.00<br />
Yellow 8 LP2T ILE5 14.00<br />
Blue 8 LP2T ILE6 14.00<br />
Transparent 8 LP2T ILE8 14.00<br />
230VAC Green 8 LP2T ILM3 14.00<br />
Red 8 LP2T ILM4 14.00<br />
Yellow 8 LP2T ILM5 14.00<br />
Blue 8 LP2T ILM6 14.00<br />
Transparent 8 LP2T ILM8 14.00<br />
Operational characteristics<br />
– Supply voltage: 12VAC/DC; 24VAC/DC; 110VAC; 230VAC<br />
– Consumption ≤20mA<br />
– <strong>Electric</strong>al life: >30,000 hours<br />
– Screw termination<br />
– Maximum tightening torque: 7.14lbin/0.8Nm<br />
– Side wire entry<br />
– Ambient conditions:<br />
• Operating temperature: +23...+104°F (-5...+40°C)<br />
• Degree of protection: IP65 on front, IP20 at rear.<br />
Materials<br />
Polyamide and polycarbonate.<br />
Maximum conductor cross section<br />
1 or 2 1.5mm 2 or 16 AWG wires.<br />
Wiring diagram<br />
LED<br />
X1<br />
X2<br />
Certifications and compliance<br />
UL listed for USA and Canada, file E93602.<br />
Compliant with standards: IEC/EN 60947-1, IEC/EN 60947-5-1.<br />
7<br />
Direct wire<br />
pilot lights with<br />
diffuser<br />
8 LP2T IL214<br />
8 LP2T IL224<br />
8 LP2T IL234<br />
Color Bulb Catalog Price<br />
supplied number $ each<br />
Screw terminals without protection.<br />
Green no 8 LP2T IL213 6.00<br />
Red no 8 LP2T IL214 6.00<br />
Yellow no 8 LP2T IL215 6.00<br />
Blue no 8 LP2T IL216 6.00<br />
Transparent no 8 LP2T IL217 6.00<br />
White no 8 LP2T IL218 6.00<br />
Screw terminals with protection.<br />
Green no 8 LP2T IL223 6.00<br />
Red no 8 LP2T IL224 6.00<br />
Yellow no 8 LP2T IL225 6.00<br />
Blue no 8 LP2T IL226 6.00<br />
Transparent no 8 LP2T IL227 6.00<br />
White no 8 LP2T IL228 6.00<br />
Faston terminals without protection ❶.<br />
Green no 8 LP2T IL233 5.00<br />
Red no 8 LP2T IL234 5.00<br />
Yellow no 8 LP2T IL235 5.00<br />
Blue no 8 LP2T IL236 5.00<br />
Transparent no 8 LP2T IL237 5.00<br />
White no 8 LP2T IL238 5.00<br />
❶ LP2T IL23... pilot lights have Faston terminals, 1-6.35 or 2-2.8.<br />
Operational characteristics<br />
– Ambient conditions:<br />
• Operating temperature: -13...+140°F (-25...+60°C)<br />
• Storage temperature: : -40...+158°F (-40...+70°C)<br />
– Any mounting poisition is allowed<br />
– Degree of protection: IP65 on front; IP20 at rear.<br />
Materials<br />
Polyamide and polycarbonate.<br />
Maximum conductor cross section<br />
1 or 2 1.5mm 2 or 16 AWG wires.<br />
Wiring diagram<br />
X1<br />
X2<br />
Bulbs<br />
Maximum recommended power: 2.6W. See page 7-20.<br />
LM2T A190❷<br />
LM2T A180❸<br />
❷ To be purchased separately .<br />
See page 7-20.<br />
❸ Standard supplied for LM2T A190❷<br />
8 LP2T IL22 only.<br />
LM2T AL...❷<br />
LM2T AT...❷<br />
Certifications and compliance<br />
UL listed for USA and Canada, file E93601 for LP2T IL21<br />
and LP2T IL22 types; UL recognized for USA and<br />
Canada, file E93601 for LP2T IL23.<br />
Compliant with standards IEC/EN 60947-1;<br />
IEC/EN 60947-5-1.<br />
Empty control<br />
station enclosures<br />
8 L2PP 2A8<br />
Description Cover Catalog Price<br />
color number $ each<br />
For 1 operator Yellow 8 L2PP 1A5 13.00<br />
For 1 operator White 8 L2PP 1A8 12.00<br />
For 2 operators White 8 L2PP 2A8 15.00<br />
For 3 operators White 8 L2PP 3A8 17.00<br />
For 4 operators White 8 L2PP 4A8 25.00<br />
For 5 operators White 8 L2PP 5A8 30.00<br />
General characteristics<br />
Control stations have wire entry through the top or the<br />
bottom and come fitted with a conduit (0.84in / 21.3 mm<br />
entry diameter).<br />
Operational characteristics<br />
Degree of protection: IP65 using adequate wire glands, not<br />
included in the supply; except 8 L2PP 5AB IP52 only.<br />
Tightening torque of cover fixing screws: 7.1lbin / 0.8 Nm.<br />
Materials<br />
Self-extinguishing ABS plastic.<br />
Certifications and compliance<br />
UL listed for USA and Canada, file E300050.<br />
Compliant with standards: IEC/EN 60947-1, IEC/EN 60947-5-1.<br />
Accessories and spare parts<br />
pages 7-19 to 20<br />
Dimensions<br />
pages D-19 and 20<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com
electric<br />
Push buttons and pilot devices, 22mm<br />
Complete control stations - Add-on contact elements<br />
7-17<br />
Complete control<br />
stations<br />
8 L2PP 160<br />
❶ Red mushroom head, twist to release, yellow cover<br />
(EN418 compliant), no label and no label holder.<br />
Mounting adapter<br />
8 LM2T AU120<br />
Contact elements<br />
8 LM2T C<br />
8 LM2T E<br />
8 LM2T CF10<br />
Description Catalog Price<br />
Enclosure + operator number $ each<br />
8 L2PP 1A8 + 8 LP2T B6244 8 L2PP 100 48.00<br />
8 L2PP 1A8 + 8 LP2T B6344 8 L2PP 110 47.00<br />
8 L2PP 1A5 + 8 LP2T B6344 8 L2PP 115 49.00<br />
8 L2PP 1A8 + 8 LP2T B6544 8 L2PP 120 52.00<br />
8 L2PP 1A5 + 8 LP2T B6644 8 L2PP 130❶ 50.00<br />
8 L2PP 1A8 + 8 LM2T B6244 8 L2PP 150 49.00<br />
8 L2PP 1A8 + 8 LM2T B6344 8 L2PP 160 48.00<br />
8 L2PP 1A5 + 8 LM2T B6344 8 L2PP 165 49.00<br />
8 L2PP 1A8 + 8 LM2T B6544 8 L2PP 170 65.00<br />
8 L2PP 1A5 + 8 LM2T B6644 8 L2PP 180❶ 58.00<br />
Description Catalog number Price<br />
$ each<br />
Only for metal series operators.<br />
Mounting adapter 8 LM2T AU120 4.00<br />
Metal series operators are supplied without mounting adapter.<br />
Plastic series operators are supplied complete with mounting<br />
adapter (type LP2T AU120).<br />
Function Catalog number Price<br />
$ each<br />
Screw termination without mounting adapter.<br />
.3<br />
NO❶<br />
8 LM2T C10❶ 6.00<br />
.4<br />
.7<br />
EM❷<br />
8 LM2T C10A 7.00<br />
.8<br />
.1<br />
NC❸<br />
8 LM2T C01 6.00<br />
.2<br />
.5<br />
LB❹<br />
8 LM2T C01D❶ 7.00<br />
.6<br />
Screw termination with mounting adapter<br />
(only for metal series operators LM2T).<br />
.3<br />
NO❶<br />
8 LM2T E10❶ 10.00<br />
.4<br />
.1<br />
NC❶❸<br />
8 LM2T E01 10.00<br />
.2<br />
Faston termination.<br />
Without mounting adapter.<br />
.3<br />
NO❶<br />
8 LM2T CF10❶ 7.60<br />
.4<br />
.1<br />
NC❸<br />
8 LM2T CF01 7.60<br />
.2<br />
❶ Not suitable for push-push operators Use LM2T C10A (EM) or LM2T C01 (NC)<br />
type only with alternate-push operators.<br />
❷ Normally open contact with early make operation.<br />
❸ Direct (positive-guided) opening operation ; safety function per<br />
IEC/EN 60947-5-1.<br />
❹ Normally closed contact with late break operation.<br />
General characteristics<br />
Control stations are supplied assembled and complete with<br />
the indicated push-button operator, mounting adapter,<br />
legend holder, “STOP” label (except for L2PP 115, L2PP<br />
130, L2PP 165 and L2PP 180) and one NC auxiliary contact.<br />
Control stations have wire entry through the top of the<br />
bottom and come fitted with a conduit (0.84in / 21.3 mm<br />
entry diameter).<br />
Operational characteristics<br />
Degree of protection: IP65 using adequate wire glands, not<br />
included in the supply.<br />
Tightening torque of cover fixing screws: 7.1lbin / 0.8 Nm.<br />
Materials<br />
Self-extinguishing ABS plastic.<br />
Reference standards<br />
IEC/EN 60947-1, IEC/EN 60947-5-1.<br />
Operational characteristics<br />
– Ambient conditions:<br />
• Operating temperature: -13...+140°F (-25...+60°C)<br />
• Storage temperature: -40...+158°F (-40...+70°C)<br />
– Any mounting position is allowed<br />
– Degree of protection: IP 20 for contacts elements with<br />
screw termination; IP00 for contact elements with Faston<br />
connection.<br />
General characteristics of contact elements<br />
Self-cleaning with dual effect, wiping and oscillating.<br />
Rated insulation voltage: 690V.<br />
Conventional free-air thermal current Ith: 10A.<br />
UL designation: A600 Q600<br />
Operational power in AC15:<br />
[V] 12 24 48 120 240 400 480 500 600<br />
[A] 6 6 6 6 3 1.9 1.5 1.4 1.2<br />
Operational power in DC13:<br />
[V] 12 24 48 125 250 440 500 600<br />
[A] 3 3 1.5 0.55 0.27 0.15 0.13 0.1<br />
Contact capacity: ≤20 mΩ.<br />
Terminals: screw with washer; Faston 1 - 0.25in (6.35mm)<br />
or 2 - 0.11in (2.8mm).<br />
Maximum tightening torque: 8.8lbin / 1Nm (Faston excluded).<br />
Stroke of auxiliary contacts [mm (in)]<br />
EM<br />
NO<br />
NC<br />
LB<br />
1(0.04) 2 (0.08) 3 (0.12) 4 (0.16) 4.8 mm (0.19in)<br />
1.8 (0.07) 2.8 (0.11in)<br />
Closed contact<br />
Open contact<br />
Maximum wire cross section<br />
1 or 2 12 AWG / 2.5 mm 2 conductors.<br />
Mechanical and electrical endurance<br />
Operating force: 1 lb / 0.5 kg (auxiliary contacts).<br />
<strong>Electric</strong>al life LM2T C10 1,000,000 cycles<br />
LM2T CF10 1,000,000 cycles<br />
LM2T C01 1,000,000 cycles<br />
LM2T CF01 1,000,000 cycles<br />
LM2T C10A 600,000 cycles<br />
LM2T C01D 600,000 cycles<br />
50 (1.97")<br />
42.4 (1.67")<br />
22.5 (0.89")<br />
30<br />
(1.18")<br />
65 (2.56") ❺<br />
7<br />
8 LM2T CF01<br />
❺ When using Faston, vertical interaxes is 35in (90mm) minimum.<br />
Certifications and compliance<br />
UL listed for USA and Canada, file E93601.<br />
Compliant with standards: IEC/EN 60947-1, IEC/EN 60947-5-1.<br />
Accessories and spare parts<br />
pages 7-20 and 21<br />
Dimensions<br />
pages D-19 and 20<br />
Wiring diagrams<br />
page W-9<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com
7-18<br />
Push buttons and pilot devices, 22mm<br />
Lamp-holders<br />
electric<br />
Lamp-holders<br />
without mounting<br />
adapter<br />
8 LM2T EL400<br />
8 LM2T ZL230<br />
8 LM2T T100<br />
8 LM2T YL<br />
8 LM2T GL<br />
Voltage Bulb Catalog number Price<br />
supplied<br />
$ each<br />
For operators of plastic and metal series.<br />
Direct supply type.<br />
≤415V no 8 LM2T EL400❶ 8.00<br />
Resistor-diode type.<br />
230VAC yes 130V 8 LM2T ZL230❹ 9.00<br />
50/60Hz (2W)<br />
Transformer type.<br />
110-120VAC yes 24V 8 LM2T YL110❷ 30.00<br />
50/60Hz (1.2W)<br />
220-240VAC yes 24V 8 LM2T YL230❷ 30.00<br />
50/60Hz (1.2W)<br />
380-415VAC yes 24V 8 LM2T YL400❷ 32.00<br />
50/60Hz (1.2W)<br />
Flashing type<br />
24-48VAC no 8 LM2T GL048❷❸ 25.00<br />
110-230VAC no 8 LM2T GL230❷❸ 25.00<br />
Test element for lamp-holders.<br />
Test element ❺❻❼ 8 LM2T T100 12.00<br />
Operational characteristics<br />
Common to all types<br />
– Ambient conditions:<br />
• Operating temperature: -13...+140°F (-25...+60°C)<br />
• Storage temperature: -40...+158°F (-40...+70°C)<br />
– Any mounting position is allowed<br />
– Degree of protection: IP 20<br />
– Maximum tightening torque: 8.8lbin/1Nm.<br />
For LED integrated lamp-holders only<br />
– Over-voltage protection<br />
– Inverse polarity protection<br />
– Shock and vibration insensitivity<br />
– Front and side visibility<br />
– Maximum consumption:<br />
• 33mA for 18-30VAC/DC<br />
• 28mA for 85-140VAC<br />
• 25mA for 187-265VAC<br />
– <strong>Electric</strong> life: 100,000 hours.<br />
For test element only<br />
– To periodically test light bulbs<br />
– AC circuits are tested with half wave so bulb<br />
luminosity is low<br />
– With DC circuits, L2 must be connected to positive (+)<br />
terminal of LM2T T100.<br />
7<br />
Lamp-holders with<br />
mounting adapter<br />
8 LM2T DL400<br />
8 LM2T VL230<br />
Voltage Bulb Catalog number Price<br />
supplied<br />
$ each<br />
Only for operators of metal series.<br />
Direct supply type.<br />
≤415V no 8 LM2T DL400❶ 11.00<br />
Resistor-diode type.<br />
230VAC yes 130V 8 LM2T VL230❹ 13.00<br />
50/60Hz (2W)<br />
Transfomer type.<br />
110-120VAC yes 24V 8 LM2T XL110❷ 35.00<br />
50/60Hz (1.2W)<br />
220-240VAC yes 24V 8 LM2T XL230❷ 35.00<br />
50/60Hz (1.2W)<br />
380-415VAC yes 24V 8 LM2T XL400❷ 37.00<br />
50/60Hz (1.2W)<br />
Flashing type.<br />
24-48VAC no 8 LM2T FL048❷❸ 30.00<br />
110-230VAC no 8 LM2T FL230❷❸ 30.00<br />
Maximum wire cross section<br />
1 or 2 12 AWG / 2.5 mm 2 conductors.<br />
Wiring diagram for lamp-holder elements<br />
Direct supply<br />
Resistor-diode<br />
LM2T EL400<br />
X1<br />
LM2T ZL230<br />
LM2T DL400<br />
LM2T VL230<br />
Transformer<br />
LM2T YL<br />
LM2T XL<br />
LED<br />
LM2T L<br />
LM2T M<br />
Assembly<br />
X1<br />
X1<br />
X2<br />
LED<br />
X2<br />
Operators latch onto the<br />
mounting adapter with a<br />
simple rotation.<br />
X2<br />
Flashing<br />
LM2T GL<br />
LM2T FL<br />
Test<br />
element<br />
X1<br />
X2<br />
X1<br />
X5<br />
TEST<br />
X1<br />
X2<br />
8 LM2T XL<br />
8 LM2T FL<br />
LED integrated<br />
lamp-holders<br />
without mounting<br />
adapter. Steady or<br />
flashing light.<br />
8 LM2T LM3<br />
Voltage LED Catalog number Price Catalog number Price<br />
❽ color for steady $ each for flashing $ each<br />
For operators of plastic and metal series.<br />
Mounting adapter excluded ❼.<br />
18-30V Green 8 LM2T LB3 9.50 8 LM2T MB3 19.00<br />
AC/DC Red 8 LM2T LB4 9.50 8 LM2T MB4 19.00<br />
Yellow 8 LM2T LB5 9.50 8 LM2T MB5 19.00<br />
Blue 8 LM2T LB6 9.50 8 LM2T MB6 19.00<br />
White 8 LM2T LB8 9.50 8 LM2T MB8 19.00<br />
85-140V Green 8 LM2T LE3 13.50 8 LM2T ME3 27.00<br />
AC Red 8 LM2T LE4 13.50 8 LM2T ME4 27.00<br />
Yellow 8 LM2T LE5 13.50 8 LM2T ME5 27.00<br />
Blue 8 LM2T LE6 13.50 8 LM2T ME6 27.00<br />
White 8 LM2T LE8 13.50 8 LM2T ME8 27.00<br />
187-265V Green 8 LM2T LM3 13.50 8 LM2T MM3 27.00<br />
AC Red 8 LM2T LM4 13.50 8 LM2T MM4 27.00<br />
Yellow 8 LM2T LM5 13.50 8 LM2T MM5 27.00<br />
Blue 8 LM2T LM6 13.50 8 LM2T MM6 27.00<br />
White 8 LM2T LM8 13.50 8 LM2T MM8 27.00<br />
❽ Steady light 9-15VAC/DC types are available on request. Contact Sales &<br />
Technical Support.<br />
Fixing to the mounting surface is<br />
by means of incorporated screws<br />
Certifications and compliance<br />
UL listed for USA and Canada, file E 93601.<br />
Compliant with standards: IEC/EN 60947-1, IEC/EN 60947-5-1.<br />
❶ Filament bulb, BA9s U≤130V max 2.6W (not supplied); max dimensions<br />
11x28 mm (0.4x1.1in). For higher voltages, use neon bulbs.<br />
❷ Not suitable for 3-position selectors.<br />
❸ Filament bulb, BA9s (not supplied); max dimensions 11x28 mm<br />
(0.4x1.1in). Suitable for AC duty only.<br />
Use bulbs with rated voltage equal to that of the power supply.<br />
E.g.: With LM2T FL230 use 120V bulbs if power supply is 120V and<br />
230V bulbs if power supply 230V. 2.6W max bulb rating.<br />
❹ MultiLED bulbs must not be fitted.<br />
❺ In case of test circuits for lamp-holders having load in parallel, two<br />
LM2T T100 elements are required for each bulb. Refer to the wiring<br />
diagram attached to the product or contact Sales & Technical Support.<br />
❻ In case of neon bulbs, contact Sales & Technical Support.<br />
❼ Luminosity is reduced during test with test element LM2T T100.<br />
Accessories and spare parts<br />
pages 7-20 and 21<br />
Dimensions<br />
page D-19<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com
electric<br />
Push buttons and pilot devices, 22mm<br />
Accessories and spare parts<br />
7-19<br />
Labels with text for<br />
8 LM2T AU100<br />
legend holder<br />
8 LM2T AGB230<br />
Inscription Catalog number Price<br />
$ each<br />
General use.<br />
Blank for writing 8 LM2T AU206 1.00<br />
Custom printed inscription ❶ 8 LM2T AU208❷ 2.50<br />
CLOSE 8 LM2T AGB216 1.50<br />
EMERGENCY 8 LM2T AGB220 1.50<br />
FAST 8 LM2T AGB231 1.50<br />
FAULT 8 LM2T AGB263 1.50<br />
FORWARD 8 LM2T AGB215 1.50<br />
LEFT 8 LM2T AGB228 1.50<br />
LOWER 8 LM2T AGB218 1.50<br />
OFF 8 LM2T AGB221 1.50<br />
ON 8 LM2T AGB223 1.50<br />
OPEN 8 LM2T AGB211 1.50<br />
POWER ON 8 LM2T AGB229 1.50<br />
RAISE 8 LM2T AGB227 1.50<br />
RESET 8 LM2T AGB226 1.50<br />
REVERSE 8 LM2T AGB222 1.50<br />
RIGHT 8 LM2T AGB217 1.50<br />
RUNNING 8 LM2T AGB241 1.50<br />
SLOW 8 LM2T AGB224 1.50<br />
START 8 LM2T AGB225 1.50<br />
STOP 8 LM2T AGB230 1.50<br />
STOP RESET 8 LM2T AGB214 1.50<br />
THERMAL FAULT 8 LM2T AGB240 1.50<br />
TRIP 8 LM2T AGB237 1.50<br />
For selector switches.<br />
AUTO-MAN 8 LM2T AI233 1.50<br />
AUTO-O-MAN 8 LM2T AI234 1.50<br />
MAN-AUTO 8 LM2T AI241 1.50<br />
MAN-O-AUTO 8 LM2T AI242 1.50<br />
FWD-O-REV 8 LM2T AGB235 1.50<br />
OFF-ON 8 LM2T AGB236 1.50<br />
STOP-START 8 LM2T AGB232 1.50<br />
International labels for push-buttons.<br />
O 8 LM2T AU200 1.50<br />
I 8 LM2T AU201 1.50<br />
II 8 LM2T AU202 1.50<br />
International labels for selector switches.<br />
O-I 8 LM2T AU203 1.50<br />
I-II 8 LM2T AU204 1.50<br />
I-O-II 8 LM2T AU205 1.50<br />
General characteristics<br />
The labels have indelible scratch-proof black lettering on<br />
metalized grey polycarbonate background (adhesive).<br />
Special versions<br />
Labels in different languages are available.<br />
Contact Sales & Technical Support.<br />
7<br />
❶ Recommended use with LM2T AU206 blank label.<br />
❷ Complete catalog number with text requided.<br />
Plastic disks for<br />
mushroom-head<br />
push-buttons<br />
Inscription Catalog number Price<br />
$ each<br />
EMERGENCY STOP Ø90mm 8 LM2T AU113 3.00<br />
EMERGENCY STOP Ø60mm 8 LM2T AU115 3.00<br />
90mm = 3.5in; 60mm = 2.4in<br />
General characteristics<br />
The disks are made of non-adhesive plastic.<br />
Special versions<br />
The disk text in different languages is available.<br />
Contact Sales & Technical Support.<br />
EMERGENCY<br />
STOP<br />
Accessories and spare parts<br />
page 7-21<br />
Dimensions<br />
page D-20<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com
7-20<br />
Push buttons and pilot devices, 22mm<br />
Accessories and spare parts<br />
electric<br />
7<br />
Accessories and<br />
spare parts<br />
8 LM2T AL...<br />
8 LM2T AU100<br />
8 LM2T AU105<br />
8 LM2T AU108<br />
8 LM2T AU106<br />
8 LM2T AU170<br />
Description Catalog number Price<br />
$ each<br />
Rod for mechanical reset 8 LM2T A150 3.00<br />
button (l=5in/123mm)<br />
BA9s bulb extractor 8 LM2T A160 0.50<br />
30mm hole size adapter 8 LM2T A161 1.00<br />
for 22mm units<br />
(2 per hole)<br />
Spare key set for 8 LM2T A170 5.00<br />
selector or mushroom<br />
head button<br />
Spare key set for 8 LM2T A170G❶ 5.00<br />
G series selector or<br />
mushroom-head button<br />
Diffuser for pilot light 8 LM2T A190 1.00<br />
Filament bulb BA9s 8 LM2T ALA024 1.50<br />
BA9s 24V - 1.2W 10x28mm<br />
Filament bulb 8 LM2T ALB024 1.50<br />
BA9s 24V - 2W 10x28mm<br />
Filament bulb 8 LM2T ALB048 1.50<br />
BA9s 48V - 2W 10x28mm<br />
Filament bulb 8 LM2T ALB130 3.00<br />
BA9s 130V - 2W 10x28mm<br />
MultiLED bulb BA9s 8 LM2T ALL006❸ 23.00<br />
6VAC/DC 10x28mm<br />
MultiLED bulb BA9s 8 LM2T ALL024❸ 23.00<br />
24VAC/DC 10x28mm<br />
MultiLED bulb BA9s 8 LM2T ALL048❸ 23.00<br />
48VAC/DC 10x28mm<br />
Neon bulb ❹ BA9s 8 LM2T ALN130❺ 8.00<br />
110/125VAC 10x28mm<br />
Neon bulb ❹ BA9s 8 LM2T ALN250❺ 8.00<br />
220/250VAC 10x28mm<br />
Neon bulb ❹ BA9s 8 LM2T ALN400❺ 8.00<br />
380/400VAC 10x28mm<br />
Neon bulb ❹ BA9s 8 LM2T ALP130❻ 1.50<br />
110/125VAC 10x28mm<br />
Neon bulb ❹ BA9s 8 LM2T ALP250❻ 1.50<br />
220/250VAC 10x28mm<br />
Neon bulb ❹ BA9s 8 LM2T ALP400❻ 1.50<br />
380/400VAC 10x28mm<br />
Blank paper label for 8 LM2T AU106 0.20<br />
writing (for LM2T AU105)<br />
Blank plastic label for 8 LM2T AU108 1.00<br />
engraving (for LM2T AU105)<br />
IP66 cap for 8 LM2T AU13❷ 2.50<br />
flush push-buttons<br />
IP66 cap for extended and 8 LM2T AU14❷ 2.50<br />
illuminated push-buttons<br />
IP66 cap for double or triple touch 8 LM2T AU157 7.00<br />
operators (transparent)<br />
Transparent protective cap 8 LM2T AU167 15.00<br />
for 8 L...2T B634 buttons<br />
Operator gasket ring 8 LM2T AU170 0.50<br />
LM2T AU170<br />
LM2T A180<br />
LM2T AL...<br />
LM2T A190<br />
LM2T AT...<br />
❶ Versions with different key code. Complete with the numeric code<br />
of the key. The following versions are available: 501, 502, 503, 504,<br />
505, 506, 507, 508, 509, 510.<br />
Example of complete catalog number: 8 LM2T A170G505.<br />
Coloured key versions are available on request; contact Sales &<br />
Technical Support.<br />
❷ For push-buttons, add the digit of the required color:<br />
2 (black); 3 (green); 4 (red); 5 (yellow); 6 (blue); 7 (transparent); 8 (white).<br />
For illuminated push-buttons, add only digit 7 (transparent).<br />
❸ Add the digit of the selected color: 3 (green); 4 (red); 5 (yellow).<br />
It is advisable to use the same color of bulb as of the actuator to<br />
obtain adequate light emission.<br />
Not suitable for resistor-diode lamp-holders.<br />
❹ Neon bulbs emit an amber light and may not be suitable for use with<br />
green or blue pilot lights and illuminated actuators.<br />
❺ Glass with diffuser lens.<br />
❻ Plastic neon bulb.<br />
Dimensions<br />
page D-20<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com
electric<br />
Push buttons and pilot devices, 22mm<br />
Accessories and spare parts<br />
7-21<br />
Accessories and<br />
spare parts<br />
8 LM2T A130<br />
8 LM2T A140<br />
Description Catalog number Price<br />
$ each<br />
Colored diffuser for double 8 LM2T A12❶ 1.00<br />
touch operators<br />
Threaded plug for unused 8 LM2T A130 3.00<br />
holes<br />
Action plug for center 8 LM2T A140 1.00<br />
contact<br />
Guard for knob selector 8 LM2T A185 4.80<br />
switches<br />
Printed label to be 8 LM2T AT❸ 1.50<br />
inserted in pilot lights<br />
and push-buttons<br />
Legend holder 8 LM2T AU100❸ 1.00<br />
Legend holder (for paper 8 LM2T AU105❸ 2.00<br />
or plastic labels)<br />
Transparent protection 8 LM2T AU107 0.50<br />
for 8 LM2T AU106 label<br />
CLICK<br />
LM2T A140<br />
LM2T AU100<br />
LM2T AU105<br />
LM2T AU170<br />
8 LM2T A185<br />
❶ Add the digit of the selected color: 3 (green); 4 (red); 5 (yellow); 6 (blue);<br />
7 (transparent); 8 (white).<br />
❷ Available only on specific request, contact Sales & Technical Support.<br />
❸ To preserve operator degree of protection (IP65), place its gasket ring between the<br />
legend holder and mounting surface.<br />
8 LM2T AT...<br />
7<br />
Accessories and<br />
spare parts for<br />
LP2T (plastic)<br />
series only<br />
Description Catalog number Price<br />
$ each<br />
IP20 terminal protection 8 LM2T A180 0.50<br />
for direct supply pilot light<br />
Socket wrench 8 LM2T A200 12.00<br />
for monoblock pilot light<br />
Mounting adapter 8 LP2T AU120 3.40<br />
LM2T AU170<br />
LM2T A180<br />
LM2T AT...<br />
LM2T AL...<br />
LM2T A190<br />
8 LM2T A180<br />
Dimensions<br />
page D-20<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com
PAGE 8-2<br />
PLASTIC LIMIT SWITCHES KB-KC TYPES<br />
• Dimensions to EN 50047 standards for KB type<br />
• Dimensions compatible to EN 50047 for KC types<br />
• Self-extinguishing polymer thermoplastic housing<br />
• Removable and interchangeable auxiliary contact<br />
blocks<br />
• Heads interchangeable and rotatable in 8 different<br />
45° angle positions<br />
• Unique fixing mechanism of operating head<br />
• IP65 protection<br />
• 1 /2 NPT or M20.<br />
PAGE 8-2<br />
METAL LIMIT SWITCHES KM-KN TYPES<br />
• Dimensions to EN 50047 standards for KM type<br />
• Dimensions compatble to EN 50047 for KN type<br />
• Aluminum-zinc alloy housing<br />
• Removable and interchangeable auxiliary contact<br />
blocks<br />
• Heads interchangeable and rotatable in 8<br />
different 45° angle positions<br />
• Unique fixing mechanism of operating head<br />
• IP65 protection<br />
• 1 /2 NPT or M20 cable entry.<br />
PAGE 8-18<br />
METAL PREWIRED LIMIT SWITCHES KP TYPE<br />
• Fixing compatible to EN 50047 standards<br />
• Aluminium-zinc alloy housing<br />
• Adjustable and capsizable levers<br />
• 2m long wire; 1m long wire types available<br />
• IP67 protection.<br />
PAGE 8-19<br />
PLASTIC LIMIT SWITCHES T SERIES<br />
• Dimensions to EN 50041 standards<br />
• Self-extinguishing polymer thermoplastic<br />
housing<br />
• Heads rotatable in 4 different 90° angle<br />
positions<br />
• IP66 protection<br />
• PG13.5 cable entry.<br />
PAGE 8-21<br />
ROPE-PULL LEVER LIMIT SWITCHES<br />
FOR NORMAL STOPPING<br />
• Self-extinguishing polymer thermoplastic<br />
housing<br />
• Aluminium-zinc alloy housing<br />
• IP40, IP65 and IP66 protection<br />
• PG11 or PG13.5 cable entry.<br />
ROPE-PULL LEVER SAFETY LIMIT SWITCHES<br />
FOR EMERGENCY STOPPING<br />
• Compliant to EN 418 standards<br />
• IP65 and IP66 protection<br />
• PG11 and PG13.5 cable entry.<br />
PAGE 8-22<br />
PLASTIC MICRO SWITCHES KS TYPE<br />
• Dimensions to EN 50047 standards<br />
• Thermoplastic reinforced resin housing<br />
• Aluminum-zinc alloy operating head<br />
• 15A 250VAC rated contact switch<br />
• 3 types of termination available.<br />
PAGE 8-23<br />
PAGES 8-24 AND 25<br />
FOOT SWITCHES<br />
• Versions with or without protection cover<br />
• Self-extinguishing polymer thermoplastic<br />
housing<br />
• Aluminum-zinc alloy housing<br />
• IP54 and IP65 protection<br />
• M20 cable entry.<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com
8<br />
LIMIT, MICRO AND FOOT SWITCHES<br />
Dimensions to EN 50047 standards<br />
Dimensions compatible to<br />
EN 50047 standards<br />
Dimensions to EN 50041 standards<br />
Direct positive operation of NC<br />
contacts<br />
Extensive range of operating heads<br />
Micro switches for general use<br />
Insertable and interchangeable<br />
auxiliary contact blocks.<br />
Micro switches for general use<br />
Prewired types with 1 or 2 meter<br />
wire length.<br />
PLANET -SWITCH<br />
The locking bayonet fixing is easily removed to<br />
allow rotation or exchange of heads, without use<br />
of tools.<br />
Heads have 45° angle axial rotation, in 8 positions.<br />
Metal and plastic limit switches, K series<br />
SEC. PAGE<br />
(dimensions to/compatible to EN 50047)<br />
Top push rod plunger limit switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8- 2<br />
Top roller push plunger limit switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8- 3<br />
Roller center push lever limit switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8- 4<br />
Roller side push lever limit switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8- 5<br />
Roller lever limit switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8- 6<br />
Adjustable roller lever limit switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8- 8<br />
Ceramic rod lever limit switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8- 10<br />
Adjustable rod lever limit switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8- 11<br />
Wobble stick, omnidirectional limit switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8- 12<br />
Hinge operating limit switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8- 13<br />
Slotted lever limit switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8- 14<br />
Key operated limit switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8- 15<br />
Prewired metal limit switches, K series . . . . . . . . . . . . . . . 8- 18<br />
Plastic limit switches, T series (dimensions to EN 50041)<br />
Top push rod plunger and roller lever limit switches . . . . . . . . . . . . . . . . . . . . . . 8- 19<br />
Wobble stick, omnidirectional and key operated limit switches . . . . . . . . . . . . . 8- 20<br />
Rope-pull lever limit switches for normal stopping . . . 8- 21<br />
Safety switches for emergency stopping<br />
EN 418 compliant . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8- 22<br />
Micro switches, K series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8- 23<br />
Foot switches, K series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8- 24<br />
Accessories and spare parts<br />
For KB - KC - KM - KN types . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8- 16<br />
PG adapters for T and RS types . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8- 21<br />
For rope-pull lever types . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8- 22<br />
For KS types . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8- 23<br />
For foot switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8- 25<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com
8<br />
8-2<br />
Top push rod plunger<br />
KB A - KM A<br />
KC A - KN A<br />
1 /2 NPT ENTRY<br />
For types with M20 entry,<br />
remove the letter N at the end of the<br />
catalog number.<br />
E.g. KB A1 S11<br />
Limit, micro and foot switches<br />
Limit switches, K series<br />
One bottom entry. Two side entries<br />
Contacts Plunger Catalog number<br />
material Plastic Metal<br />
body Price body Price<br />
$ each $ each<br />
One bottom entry. Dimensions to EN 50047.<br />
1NO+1NC Metal KB A1 S11N 29.00 KM A1 S11N 38.00<br />
Snap action❶<br />
2NC Metal KB A1 S02N 38.00 KM A1 S02N 47.00<br />
Snap action❶<br />
1NO+1NC Metal KB A1 A11N 27.00 KM A1 A11N 36.00<br />
Slow break make<br />
before break❶<br />
1NO+1NC Metal KB A1 L11N 27.00 KM A1 L11N 36.00<br />
Slow break❶<br />
2NC Metal KB A1 L02N 29.00 KM A1 L02N 38.00<br />
Slow break❶<br />
2NO Metal KB A1 L20N 29.00 KM A1 L20N 38.00<br />
Slow break<br />
1NO+2NC Metal KB A1 L12N 40.00 KM A1 L12N 49.00<br />
Slow break❶<br />
2NO+1NC Metal KB A1 L21N 40.00 KM A1 L21N 49.00<br />
Slow break❶<br />
3NC Metal KB A1 L03N 40.00 KM A1 L03N 49.00<br />
Slow break❶<br />
Two side entries. Dimensions compatible to EN 50047.<br />
1NO+1NC Metal KC A1 S11N 34.00 KN A1 S11N 42.00<br />
Snap action❶<br />
2NC Metal KC A1 S02N 42.00 KN A1 S02N 51.00<br />
Snap action❶<br />
1NO+1NC Metal KC A1 A11N 32.00 KN A1 A11N 40.00<br />
Slow break make<br />
before break❶<br />
1NO+1NC Metal KC A1 L11N 32.00 KN A1 L11N 40.00<br />
Slow break❶<br />
2NC Metal KC A1 L02N 34.00 KN A1 L02N 42.00<br />
Slow break❶<br />
2NO Metal KC A1 L20N 34.00 KN A1 L20N 42.00<br />
Slow break<br />
❶ Direct (positive-guided) opening operation<br />
IEC/EN 60947-5-1.<br />
; safety function per<br />
electric<br />
General characteristics<br />
The LOVATO ELECTRIC limit switches have been<br />
designed to satisfy requirements for quick installation,<br />
wiring ease, simple setup, modularity, sturdiness and<br />
reliability.<br />
The body cover is hinged at the bottom and removable.<br />
The innovative locking bayonet mechanism provides for<br />
easy removal and repositioning of the operating head in<br />
the required configuration without tools. The heads have<br />
axial rotation of 45° angles.<br />
The auxiliary contact blocks are removable assuring<br />
wiring simplicity. The heads are made of metal while the<br />
body housing of self-extinguishing polymer<br />
thermoplastic for the KB and KC types or of<br />
aluminum-zinc alloy (zama) for the KM and KN types.<br />
Operational characteristics<br />
– Maximum operating rate: 3600 cycles/h<br />
– Switching time: 0.5-1.5m/s<br />
– Mechanical life: >10 million cycles<br />
– Conventional thermal current Ith: 10A<br />
– UL designation:<br />
• A600 Q300 for KB-KC types<br />
• A300 Q300 for KM-KN types<br />
– Rated insulation voltage Ui:<br />
• 690VAC for KB-KC types<br />
• 440VAC for KM-KN types<br />
– Rated impulse withstand voltage Uimp:<br />
• 6kV for KB-KC types<br />
• 4kV for KM-KN types<br />
– Class II insulation for KB-KC only<br />
– Contact resistance:
electric<br />
Top roller push<br />
plunger<br />
KB B - KM B<br />
KC B - KN B<br />
1 /2 NPT ENTRY<br />
For types with M20 entry,<br />
remove the letter N at the end of the<br />
catalog number.<br />
E.g. KB B1 S11<br />
Limit, micro and foot switches<br />
Limit switches, K series<br />
One bottom entry. Two side entries<br />
Contacts Roller Catalog number<br />
material Plastic Metal<br />
body Price body Price<br />
$ each $ each<br />
One bottom cable entry. Dimensions to EN 50047.<br />
1NO+1NC Plastic KB B1 S11N 33.00 KM B1 S11N 42.00<br />
Snap action❶ Metal KB B2 S11N 35.00 KM B2 S11N 44.00<br />
2NC Plastic KB B1 S02N 42.00 KM B1 S02N 51.00<br />
Snap action❶ Metal KB B2 S02N 43.00 KM B2 S02N 52.00<br />
1NO+1NC Plastic KB B1 A11N 31.00 KM B1 A11N 40.00<br />
Slow break make<br />
before break❶<br />
Metal KB B2 A11N 33.00 KM B2 A11N 42.00<br />
1NO+1NC Plastic KB B1 L11N 31.00 KM B1 L11N 40.00<br />
Slow break❶ Metal KB B2 L11N 33.00 KM B2 L11N 44.00<br />
2NC Plastic KB B1 L02N 31.00 KM B1 L02N 42.00<br />
Slow break❶ Metal KB B2 L02N 35.00 KM B2 L02N 44.00<br />
2NO Plastic KB B1 L20N 33.00 KM B1 L20N 42.00<br />
Slow break Metal KB B2 L20N 35.00 KM B2 L20N 44.00<br />
1NO+2NC Plastic KB B1 L12N 44.00 KM B1 L12N 53.00<br />
Slow break❶ Metal KB B2 L12N 46.00 KM B2 L12N 55.00<br />
2NO+1NC Plastic KB B1 L21N 44.00 KM B1 L21N 53.00<br />
Slow break❶ Metal KB B2 L21N 46.00 KM B2 L21N 55.00<br />
3NC Plastic KB B1 L03N 44.00 KM B1 L03N 53.00<br />
Slow break❶ Metal KB B2 L03N 46.00 KM B2 L03N 55.00<br />
Two side entries. Dimensions compatible to EN 50047.<br />
1NO+1NC Plastic KC B1 S11N 38.00 KN B1 S11N 46.00<br />
Snap action❶ Metal KC B2 S11N 40.00 KN B2 S11N 48.00<br />
2NC Plastic KC B1 S02N 47.00 KN B1 S02N 55.00<br />
Snap action❶ Metal KC B2 S02N 48.00 KN B2 S02N 57.00<br />
1NO+1NC Plastic KC B1 A11N 36.00 KN B1 A11N 44.00<br />
Slow break make<br />
before break❶<br />
Metal KC B2 A11N 37.00 KN B2 A11N 46.00<br />
1NO+1NC Plastic KC B1 L11N 36.00 KN B1 L11N 44.00<br />
Slow break❶ Metal KC B2 L11N 37.00 KN B2 L11N 46.00<br />
2NC Plastic KC B1 L02N 38.00 KN B1 L02N 48.00<br />
Slow break❶ Metal KC B2 L02N 40.00 KN B2 L02N 48.00<br />
2NO Plastic KC B1 L20N 38.00 KN B1 L20N 46.00<br />
Slow break Metal KC B2 L20N 40.00 KN B2 L20N 48.00<br />
❶ Direct (positive-guided) opening operation ; safety function per<br />
IEC/EN 60947-5-1.<br />
8-3<br />
General characteristics<br />
The LOVATO ELECTRIC limit switches have been<br />
designed to satisfy requirements for quick installation,<br />
wiring ease, simple setup, modularity, sturdiness and<br />
reliability.<br />
The body cover is hinged at the bottom and removable.<br />
The innovative locking bayonet mechanism provides for<br />
easy removal and repositioning of the operating head in<br />
the required configuration without tools. The heads have<br />
axial rotation of 45° angles.<br />
The auxiliary contact blocks are removable assuring<br />
wiring simplicity. The heads are made of metal while the<br />
body housing of self-extinguishing polymer<br />
thermoplastic for the KB and KC types or of<br />
aluminum-zinc alloy (zama) for the KM and KN types.<br />
Operational characteristics<br />
– Maximum operating rate: 3600 cycles/h<br />
– Switching time: 0.5-1.5m/s<br />
– Mechanical life: >10 million cycles<br />
– Conventional thermal current Ith: 10A<br />
– UL designation:<br />
• A600 Q300 for KB-KC types<br />
• A300 Q300 for KM-KN types<br />
– Rated insulation voltage Ui:<br />
• 690VAC for KB-KC types<br />
• 440VAC for KM-KN types<br />
– Rated impulse withstand voltage Uimp:<br />
• 6kV for KB-KC types<br />
• 4kV for KM-KN types<br />
– Class II insulation for KB-KC only<br />
– Contact resistance:
8<br />
8-4<br />
Roller center push<br />
lever<br />
KB C - KM C<br />
KC C - KN C<br />
1 /2 NPT ENTRY<br />
For types with M20 entry,<br />
remove the letter N at the end of the<br />
catalog number.<br />
E.g. KB C1 S11<br />
Limit, micro and foot switches<br />
Limit switches, K series<br />
One bottom entry. Two side entries<br />
Contacts Roller Catalog number<br />
material Plastic Metal<br />
body Price body Price<br />
$ each $ each<br />
One bottom entry. Dimensions to EN 50047.<br />
1NO+1NC Plastic KB C1 S11N 34.00 KM C1 S11N 43.00<br />
Snap action❶ Metal KB C2 S11N 35.00 KM C2 S11N 44.00<br />
2NC Plastic KB C1 S02N 42.00 KM C1 S02N 51.00<br />
Snap action❶ Metal KB C2 S02N 44.00 KM C2 S02N 53.00<br />
1NO+1NC Plastic KB C1 A11N 32.00 KM C1 A11N 41.00<br />
Slow break make<br />
before break❶<br />
Metal KB C2 A11N 33.00 KM C2 A11N 42.00<br />
1NO+1NC Plastic KB C1 L11N 32.00 KM C1 L11N 41.00<br />
Slow break❶ Metal KB C2 L11N 33.00 KM C2 L11N 42.00<br />
2NC Plastic KB C1 L02N 34.00 KM C1 L02N 43.00<br />
Slow break❶ Metal KB C2 L02N 35.00 KM C2 L02N 44.00<br />
2NO Plastic KB C1 L20N 34.00 KM C1 L20N 43.00<br />
Slow break Metal KB C2 L20N 35.00 KM C2 L20N 44.00<br />
1NO+2NC Plastic KB C1 L12N 45.00 KM C1 L12N 54.00<br />
Slow break❶ Metal KB C2 L12N 46.00 KM C2 L12N 55.00<br />
2NO+1NC Plastic KB C1 L21N 45.00 KM C1 L21N 54.00<br />
Slow break❶ Metal KB C2 L21N 46.00 KM C2 L21N 55.00<br />
3NO Plastic KB C1 L03N 45.00 KM C1 L03N 54.00<br />
Slow break❶ Metal KB C2 L03N 46.00 KM C2 L03N 55.00<br />
Two side entries. Dimensions compatible to EN 50047.<br />
1NO+1NC Plastic KC C1 S11N 38.00 KN C1 S11N 47.00<br />
Snap action❶ Metal KC C2 S11N 40.00 KN C2 S11N 48.00<br />
2NC Plastic KC C1 S02N 47.00 KN C1 S02N 56.00<br />
Snap action❶ Metal KC C2 S02N 49.00 KN C2 S02N 57.00<br />
1NO+1NC Plastic KC C1 A11N 36.00 KN C1 A11N 45.00<br />
Slow break make<br />
before break❶<br />
Metal KC C2 A11N 38.00 KN C2 A11N 46.00<br />
1NO+1NC Plastic KC C1 L11N 36.00 KN C1 L11N 45.00<br />
Slow break❶ Metal KC C2 L11N 38.00 KN C2 L11N 46.00<br />
2NC Plastic KC C1 L02N 38.00 KN C1 L02N 47.00<br />
Slow break❶ Metal KC C2 L02N 40.00 KN C2 L02N 48.00<br />
2NO Plastic KC C1 L20N 38.00 KN C1 L20N 47.00<br />
Slow break Metal KC C2 L20N 40.00 KN C2 L20N 48.00<br />
Ø11x4mm =0.43x0.16in<br />
❶ Direct (positive-guided) opening operation ; safety function per<br />
IEC/EN 60947-5-1.<br />
electric<br />
General characteristics<br />
The LOVATO ELECTRIC limit switches have been<br />
designed to satisfy requirements for quick installation,<br />
wiring ease, simple setup, modularity, sturdiness and<br />
reliability.<br />
The body cover is hinged at the bottom and removable.<br />
The innovative locking bayonet mechanism provides for<br />
easy removal and repositioning of the operating head in<br />
the required configuration without tools. The heads have<br />
axial rotation of 45° angles.<br />
The auxiliary contact blocks are removable assuring<br />
wiring simplicity. The heads are made of metal while the<br />
body housing of self-extinguishing polymer<br />
thermoplastic for the KB and KC types or of<br />
aluminum-zinc alloy (zama) for the KM and KN types.<br />
Operational characteristics<br />
– Maximum operating rate: 3600 cycles/h<br />
– Switching time: 0.5-1.5m/s<br />
– Mechanical life: >10 million cycles<br />
– Conventional thermal current Ith: 10A<br />
– UL designation:<br />
• A600 Q300 for KB-KC types<br />
• A300 Q300 for KM-KN types<br />
– Rated insulation voltage Ui:<br />
• 690VAC for KB-KC types<br />
• 440VAC for KM-KN types<br />
– Rated impulse withstand voltage Uimp:<br />
• 6kV for KB-KC types<br />
• 4kV for KM-KN types<br />
– Class II insulation for KB-KC only<br />
– Contact resistance:
electric<br />
Roller side push<br />
lever<br />
KB D - KM D<br />
KC D - KN D<br />
1 /2 NPT ENTRY<br />
For types with M20 entry,<br />
remove the letter N at the end of the<br />
catalog number.<br />
E.g. KB D1 S11<br />
Limit, micro and foot switches<br />
Limit switches, K series<br />
One bottom entry. Two side entries<br />
Contacts Roller Catalog number<br />
material Plastic Metal<br />
body Price body Price<br />
$ each $ each<br />
One bottom entry. Dimensions to EN 50047.<br />
1NO+1NC Plastic KB D1 S11N 34.00 KM D1 S11N 43.00<br />
Snap action❶ Metal KB D2 S11N 35.00 KM D2 S11N 44.00<br />
2NC Plastic KB D1 S02N 42.00 KM D1 S02N 51.00<br />
Snap action❶ Metal KB D2 S02N 43.00 KM D2 S02N 53.00<br />
1NO+1NC Plastic KB D1 A11N 32.00 KM D1 A11N 41.00<br />
Slow break make<br />
before break❶<br />
Metal KB D2 A11N 33.00 KM D2 A11N 42.00<br />
1NO+1NC Plastic KB D1 L11N 32.00 KM D1 L11N 41.00<br />
Slow break❶ Metal KB D2 L11N 33.00 KM D2 L11N 42.00<br />
2NC Plastic KB D1 L02N 34.00 KM D1 L02N 43.00<br />
Slow break❶ Metal KB D2 L02N 35.00 KM D2 L02N 44.00<br />
2NO Plastic KB D1 L20N 34.00 KM D1 L20N 43.00<br />
Slow break Metal KB D2 L20N 35.00 KM D2 L20N 44.00<br />
1NO+2NC Plastic KB D1 L12N 45.00 KM D1 L12N 54.00<br />
Slow break❶ Metal KB D2 L12N 46.00 KM D2 L12N 55.00<br />
2NO+1NC Plastic KB D1 L21N 45.00 KM D1 L21N 54.00<br />
Slow break❶ Metal KB D2 L21N 46.00 KM D2 L21N 55.00<br />
3NC Plastic KB D1 L03N 45.00 KM D1 L03N 54.00<br />
Slow break❶ Metal KB D2 L03N 46.00 KM D2 L03N 55.00<br />
Two side entries. Dimensions compatible to EN 50047.<br />
1NO+1NC Plastic KC D1 S11N 38.00 KN D1 S11N 47.00<br />
Snap action❶ Metal KC D2 S11N 40.00 KN D2 S11N 48.00<br />
2NC Plastic KC D1 S02N 47.00 KN D1 S02N 56.00<br />
Snap action❶ Metal KC D2 S02N 49.00 KN D2 S02N 57.00<br />
1NO+1NC Plastic KC D1 A11N 36.00 KN D1 A11N 45.00<br />
Slow break make<br />
before break❶<br />
Metal KC D2 A11N 38.00 KN D2 A11N 46.00<br />
1NO+1NC Plastic KC D1 L11N 36.00 KN D1 L11N 45.00<br />
Slow break❶ Metal KC D2 L11N 38.00 KN D2 L11N 46.00<br />
2NC Plastic KC D1 L02N 38.00 KN D1 L02N 47.00<br />
Slow break❶ Metal KC D2 L02N 40.00 KN D2 L02N 48.00<br />
2NO Plastic KC D1 L20N 38.00 KN D1 L20N 47.00<br />
Slow break Metal KC D2 L20N 40.00 KN D2 L20N 48.00<br />
Ø11x4mm =0.43x0.16in<br />
❶ Direct (positive-guided) opening operation ; safety function per<br />
IEC/EN 60947-5-1.<br />
8-5<br />
General characteristics<br />
The LOVATO ELECTRIC limit switches have been<br />
designed to satisfy requirements for quick installation,<br />
wiring ease, simple setup, modularity, sturdiness and<br />
reliability.<br />
The body cover is hinged at the bottom and removable.<br />
The innovative locking bayonet mechanism provides for<br />
easy removal and repositioning of the operating head in<br />
the required configuration without tools. The heads have<br />
axial rotation of 45° angles.<br />
The auxiliary contact blocks are removable assuring<br />
wiring simplicity. The heads are made of metal while the<br />
body housing of self-extinguishing polymer<br />
thermoplastic for the KB and KC types or of<br />
aluminum-zinc alloy (zama) for the KM and KN types.<br />
Operational characteristics<br />
– Maximum operating rate: 3600 cycles/h<br />
– Switching time: 0.5-1.5m/s<br />
– Mechanical life: >10 million cycles<br />
– Conventional thermal current Ith: 10A<br />
– UL designation:<br />
• A600 Q300 for KB-KC types<br />
• A300 Q300 for KM-KN types<br />
– Rated insulation voltage Ui:<br />
• 690VAC for KB-KC types<br />
• 440VAC for KM-KN types<br />
– Rated impulse withstand voltage Uimp:<br />
• 6kV for KB-KC types<br />
• 4kV for KM-KN types<br />
– Class II insulation for KB-KC only<br />
– Contact resistance:
8<br />
8-6<br />
Roller lever plunger<br />
KB E1 - KB E2<br />
KM E1 - KM E2<br />
KB E3 - KM E3<br />
Limit, micro and foot switches<br />
Limit switches, K series<br />
One bottom entry<br />
Contacts Roller Catalog number<br />
material Plastic Metal<br />
body Price body Price<br />
$ each $ each<br />
One bottom entry. Dimensions to EN 50047.<br />
1NO+1NC Plastic❶ KB E1 S11N 36.00 KM E1 S11N 45.00<br />
Snap action❸ Metal❶ KB E2 S11N 38.00 KM E2 S11N 47.00<br />
Rubber❷ KB E3 S11N 42.00 KM E3 S11N 51.00<br />
2NC Plastic❶ KB E1 S02N 44.00 KM E1 S02N 53.00<br />
Snap action❸ Metal❶ KB E2 S02N 47.00 KM E2 S02N 56.00<br />
Rubber❷ KB E3 S02N 51.00 KM E3 S02N 60.00<br />
1NO+1NC Plastic❶ KB E1 A11N 34.00 KM E1 A11N 43.00<br />
Slow break make Metal❶ KB E2 A11N 36.00 KM E2 A11N 45.00<br />
before break❸ Rubber❷ KB E3 A11N 40.00 KM E3 A11N 49.00<br />
1NO+1NC Plastic❶ KB E1 L11N 34.00 KM E1 L11N 43.00<br />
Slow break❸ Metal❶ KB E2 L11N 36.00 KM E2 L11N 45.00<br />
Rubber❷ KB E3 L11N 40.00 KM E3 L11N 49.00<br />
2NC Plastic❶ KB E1 L02N 36.00 KM E1 L02N 45.00<br />
Slow break❸ Metal❶ KB E2 L02N 38.00 KM E2 L02N 47.00<br />
Rubber❷ KB E3 L02N 42.00 KM E3 L02N 51.00<br />
2NO Plastic❶ KB E1 L20N 36.00 KM E1 L20N 45.00<br />
Slow break Metal❶ KB E2 L20N 38.00 KM E2 L20N 47.00<br />
Rubber❷ KB E3 L20N 42.00 KM E3 L20N 51.00<br />
1NO+2NC Plastic❶ KB E1 L12N 47.00 KM E1 L12N 56.00<br />
Slow break❸ Metal❶ KB E2 L12N 49.00 KM E2 L12N 58.00<br />
Rubber❷ KB E3 L12N 53.00 KM E3 L12N 62.00<br />
2NO+1NC Plastic❶ KB E1 L21N 47.00 KM E1 L21N 56.00<br />
Slow break❸ Metal❶ KB E2 L21N 49.00 KM E2 L21N 58.00<br />
Rubber❷ KB E3 L21N 53.00 KM E3 L21N 62.00<br />
3NC Plastic❶ KB E1 L03N 47.00 KM E1 L03N 56.00<br />
Slow break❸ Metal❶ KB E2 L03N 49.00 KM E2 L03N 58.00<br />
Rubber❷ KB E3 L03N 53.00 KM E3 L03N 62.00<br />
BI-DIRECTIONAL.<br />
One bottom entry. Dimensions to EN 50047.<br />
2NC❸ Plastic❶ KB E1 D02N 50.00 KM E1 D02N 58.00<br />
Independent<br />
❶ Ø19x5mm = 0.75x0.2in<br />
❷ Ø50x10mm = 1.97x0.39in<br />
❸ Direct (positive-guided) opening operation ; safety function per<br />
IEC/EN 60947-5-1.<br />
electric<br />
General characteristics<br />
The LOVATO ELECTRIC limit switches have been<br />
designed to satisfy requirements for quick installation,<br />
wiring ease, simple setup, modularity, sturdiness and<br />
reliability.<br />
The body cover is hinged at the bottom and removable.<br />
The innovative locking bayonet mechanism provides for<br />
easy removal and repositioning of the operating head in<br />
the required configuration without tools. The heads have<br />
axial rotation of 45° angles.<br />
The auxiliary contact blocks are removable assuring<br />
wiring simplicity. The heads are made of metal while the<br />
body housing of self-extinguishing polymer<br />
thermoplastic for the KB types or of<br />
aluminum-zinc alloy (zama) for the KM types.<br />
Operational characteristics<br />
– Maximum operating rate: 3600 cycles/h<br />
– Switching time: 0.5-1.5m/s<br />
– Mechanical life: >10 million cycles<br />
– Conventional thermal current Ith: 10A<br />
– UL designation:<br />
• A600 Q300 for KB types<br />
• A300 Q300 for KM types<br />
– Rated insulation voltage Ui:<br />
• 690V for KB types<br />
• 440V for KM types<br />
– Rated impulse withstand voltage Uimp:<br />
• 6kVAC for KB types<br />
• 4kVAC for KM types<br />
– Class II insulation for KB only<br />
– Contact resistance:
electric<br />
Roller lever plunger<br />
KC E1 - KC E2<br />
KN E1 - KN E2<br />
KC E3 - KN E3<br />
Limit, micro and foot switches<br />
Limit switches, K series<br />
Two side entries.<br />
Contacts Roller Catalog number<br />
material Plastic Metal<br />
body Price body Price<br />
$ each $ each<br />
Two side entries. Dimensions compatible to EN 50047.<br />
1NO+1NC Plastic❶ KC E1 S11N 40.00 KN E1 S11N 49.00<br />
Snap action❸ Metal❶ KC E2 S11N 43.00 KN E2 S11N 51.00<br />
Rubber❷ KC E3 S11N 47.00 KN E3 S11N 55.00<br />
2NC Plastic❶ KC E1 S02N 49.00 KN E1 S02N 57.00<br />
Snap action❸ Metal❶ KC E2 S02N 52.00 KN E2 S02N 60.00<br />
Rubber KC E3 S02N 56.00 KN E3 S02N 64.00<br />
1NO+1NC Plastic❶ KC E1 A11N 38.00 KN E1 A11N 47.00<br />
Slow break make Metal❶ KC E2 A11N 41.00 KN E2 A11N 49.00<br />
before break❸ Rubber❷ KC E3 A11N 45.00 KN E3 A11N 53.00<br />
1NO+1NC Plastic❶ KC E1 L11N 38.00 KN E1 L11N 47.00<br />
Slow break❸ Metal❶ KC E2 L11N 41.00 KN E2 L11N 49.00<br />
Rubber❷ KC E3 L11N 45.00 KN E3 L11N 53.00<br />
2NC Plastic❶ KC E1 L02N 40.00 KN E1 L02N 49.00<br />
Slow break❸ Metal❶ KC E2 L02N 43.00 KN E2 L02N 51.00<br />
Rubber❷ KC E3 L02N 47.00 KN E3 L02N 55.00<br />
2NO Plastic❶ KC E1 L20N 40.00 KN E1 L20N 49.00<br />
Slow break Metal❶ KC E2 L20N 43.00 KN E2 L20N 51.00<br />
Rubber❷ KC E3 L20N 47.00 KN E3 L20N 55.00<br />
BI-DIRECTIONAL.<br />
One bottom entry. Dimensions to EN 50047.<br />
2NC❸ Plastic❶ KC E1 D02N 54.00 KN E1 D02N 61.00<br />
Independent<br />
❶ Ø19x5mm = 0.75x0.2in<br />
❷ Ø50x10mm = 1.97x0.39in<br />
❸ Direct (positive-guided) opening operation ; safety function per<br />
IEC/EN 60947-5-1.<br />
8-7<br />
General characteristics<br />
The LOVATO ELECTRIC limit switches have been<br />
designed to satisfy requirements for quick installation,<br />
wiring ease, simple setup, modularity, sturdiness and<br />
reliability.<br />
The body cover is hinged at the bottom and removable.<br />
The innovative locking bayonet mechanism provides for<br />
easy removal and repositioning of the operating head in<br />
the required configuration without tools. The heads have<br />
axial rotation of 45° angles.<br />
The auxiliary contact blocks are removable assuring<br />
wiring simplicity. The heads are made of metal while the<br />
body housing of self-extinguishing polymer<br />
thermoplastic for the KC types or of<br />
aluminum-zinc alloy (zama) for the KN types.<br />
Operational characteristics<br />
– Maximum operating rate: 3600 cycles/h<br />
– Switching time: 0.5-1.5m/s<br />
– Mechanical life: >10 million cycles<br />
– Conventional thermal current Ith: 10A<br />
– UL designation:<br />
• A600 Q300 for KC types<br />
• A300 Q300 for KN types<br />
– Rated insulation voltage Ui:<br />
• 690VAC for KC types<br />
• 440VAC for KN types<br />
– Rated impulse withstand voltage Uimp:<br />
• 6kV for KC types<br />
• 4kV for KN types<br />
– Class II insulation for KC only<br />
– Contact resistance:
8<br />
8-8<br />
Adjustable roller<br />
lever<br />
KB F - KM F<br />
1 /2 NPT ENTRY<br />
For types with M20 entry,<br />
remove the letter N at the end of the<br />
catalog number.<br />
E.g. KB F1 S11<br />
❶ Ø19x5mm = 0.75x0.2in<br />
❷ Ø50x10mm = 1.97x0.39in<br />
❸ Ø50x10mm = 1.97x0.39in off alignment<br />
❹ Direct (positive-guided) opening operation ;<br />
safety function per IEC/EN 60947-5-1.<br />
Limit, micro and foot switches<br />
Limit switches, K series<br />
One side entry<br />
Contacts Roller Catalog number<br />
material Plastic Metal<br />
body Price body Price<br />
$ each $ each<br />
One bottom entry. Dimensions to EN 50047.<br />
1NO+1NC Plastic❶ KB F1 S11N 37.00 KM F1 S11N 46.00<br />
Snap action❹ Metal❶ KB F2 S11N 40.00 KM F2 S11N 49.00<br />
Rubber❷ KB F3 S11N 43.00 KM F3 S11N 52.00<br />
Rubber❸ KB F4 S11N 45.00 KM F4 S11N 54.00<br />
2NC Plastic❶ KB F1 S02N 46.00 KM F1 S02N 55.00<br />
Snap action❹ Metal❶ KB F2 S02N 48.00 KM F2 S02N 57.00<br />
Rubber❷ KB F3 S02N 52.00 KM F3 S02N 61.00<br />
Rubber❸ KB F4 S02N 54.00 KM F4 S02N 63.00<br />
1NO+1NC Plastic❶ KB F1 A11N 35.00 KM F1 A11N 44.00<br />
Slow break make Metal❶ KB F2 A11N 38.00 KM F2 A11N 47.00<br />
before break❹ Rubber❷ KB F3 A11N 41.00 KM F3 A11N 50.00<br />
Rubber❸ KB F4 A11N 43.00 KM F4 A11N 52.00<br />
1NO+1NC Plastic❶ KB F1 L11N 35.00 KM F1 L11N 44.00<br />
Slow break❹ Metal❶ KB F2 L11N 38.00 KM F2 L11N 47.00<br />
Rubber❷ KB F3 L11N 41.00 KM F3 L11N 50.00<br />
Rubber❸ KB F4 L11N 43.00 KM F4 L11N 52.00<br />
2NC Plastic❶ KB F1 L02N 37.00 KM F1 L02N 46.00<br />
Slow break❹ Metal❶ KB F2 L02N 40.00 KM F2 L02N 49.00<br />
Rubber❷ KB F3 L02N 43.00 KM F3 L02N 52.00<br />
Rubber❸ KB F4 L02N 45.00 KM F4 L02N 54.00<br />
2NO Plastic❶ KB F1 L20N 37.00 KM F1 L20N 46.00<br />
Slow break Metal❶ KB F2 L20N 40.00 KM F2 L20N 49.00<br />
Rubber❷ KB F3 L20N 43.00 KM F3 L20N 52.00<br />
Rubber❸ KB F4 L20N 45.00 KM F4 L20N 54.00<br />
1NO+2NC Plastic❶ KB F1 L12N 48.00 KM F1 L12N 57.00<br />
Slow break❹ Metal❶ KB F2 L12N 51.00 KM F2 L12N 60.00<br />
Rubber❷ KB F3 L12N 54.00 KM F3 L12N 63.00<br />
Rubber❸ KB F4 L12N 56.00 KM F4 L12N 65.00<br />
2NO+1NC Plastic❶ KB F1 L21N 48.00 KM F1 L21N 57.00<br />
Slow break❹ Metal❶ KB F2 L21N 51.00 KM F2 L21N 60.00<br />
Rubber❷ KB F3 L21N 54.00 KM F3 L21N 63.00<br />
Rubber❸ KB F4 L21N 56.00 KM F4 L21N 65.00<br />
3NC Plastic❶ KB F1 L03N 48.00 KM F1 L03N 57.00<br />
Slow break❹ Metal❶ KB F2 L03N 51.00 KM F2 L03N 60.00<br />
Rubber❷ KB F3 L03N 54.00 KM F3 L03N 63.00<br />
Rubber❸ KB F4 L03N 56.00 KM F4 L03N 65.00<br />
BI-DIRECTIONAL.<br />
One bottom entry. Dimensions to EN 50047.<br />
2NC❸ Plastic❶ KB F1 D02N 52.00 KM F1 D02N 60.00<br />
Independent<br />
electric<br />
General characteristics<br />
The LOVATO ELECTRIC limit switches have been<br />
designed to satisfy requirements for quick installation,<br />
wiring ease, simple setup, modularity, sturdiness and<br />
reliability.<br />
The body cover is hinged at the bottom and removable.<br />
The innovative locking bayonet mechanism provides for<br />
easy removal and repositioning of the operating head in<br />
the required configuration without tools.<br />
The auxiliary contact blocks are removable assuring<br />
wiring simplicity. The heads are made of metal while the<br />
body housing of self-extinguishing polymer<br />
thermoplastic for the KB types or of<br />
aluminum-zinc alloy (zama) for the KM types.<br />
Operational characteristics<br />
– Maximum operating rate: 3600 cycles/h<br />
– Switching time: 0.5-1.5m/s<br />
– Mechanical life: >10 million cycles<br />
– Conventional thermal current Ith: 10A<br />
– UL designation:<br />
• A600 Q300 for KB types<br />
• A300 Q300 for KM types<br />
– Rated insulation voltage Ui:<br />
• 690V for KB types<br />
• 440V for KM types<br />
– Rated impulse withstand voltage Uimp:<br />
• 6kVAC for KB types<br />
• 4kVAC for KM types<br />
– Class II insulation for KB only<br />
– Contact resistance:
electric<br />
Adjustable roller<br />
lever<br />
KC F - KN F<br />
1 /2 NPT ENTRY<br />
For types with M20 entry,<br />
remove the letter N at the end of the<br />
catalog number.<br />
E.g. KC F1 S11<br />
Limit, micro and foot switches<br />
Limit switches, K series<br />
Two side entries<br />
Contacts Roller Catalog number<br />
material Plastic Metal<br />
body Price body Price<br />
$ each $ each<br />
Two side entries. Dimensions compatible to EN 50047.<br />
1NO+1NC Plastic❶ KC F1 S11N 42.00 KN F1 S11N 50.00<br />
Snap action❹ Metal❶ KC F2 S11N 45.00 KN F2 S11N 53.00<br />
Rubber❷ KC F3 S11N 48.00 KN F3 S11N 56.00<br />
Rubber❸ KC F4 S11N 50.00 KN F4 S11N 59.00<br />
2NC Plastic❶ KC F1 S02N 51.00 KN F1 S02N 59.00<br />
Snap action❹ Metal❶ KC F2 S02N 53.00 KN F2 S02N 62.00<br />
Rubber❷ KC F3 S02N 57.00 KN F3 S02N 65.00<br />
Rubber❸ KC F4 S02N 59.00 KN F4 S02N 67.00<br />
1NO+1NC Plastic❶ KC F1 A11N 40.00 KN F1 A11N 48.00<br />
Slow break make Metal❶ KC F2 A11N 43.00 KN F2 A11N 51.00<br />
before break❹ Rubber❷ KC F3 A11N 46.00 KN F3 A11N 54.00<br />
Rubber❸ KC F4 A11N 48.00 KN F4 A11N 56.00<br />
1NO+1NC Plastic❶ KC F1 L11N 40.00 KN F1 L11N 48.00<br />
Slow break❹ Metal❶ KC F2 L11N 43.00 KN F2 L11N 51.00<br />
Rubber❷ KC F3 L11N 46.00 KN F3 L11N 54.00<br />
Rubber❸ KC F4 L11N 48.00 KN F4 L11N 56.00<br />
2NC Plastic❶ KC F1 L02N 42.00 KN F1 L02N 50.00<br />
Slow break❹ Metal❶ KC F2 L02N 45.00 KN F2 L02N 53.00<br />
Rubber❷ KC F3 L02N 48.00 KN F3 L02N 56.00<br />
Rubber❸ KC F4 L02N 50.00 KN F4 L02N 59.00<br />
2NO Plastic❶ KC F1 L20N 42.00 KN F1 L20N 50.00<br />
Slow break Metal❶ KC F2 L20N 45.00 KN F2 L20N 53.00<br />
Rubber❷ KC F3 L20N 48.00 KN F3 L20N 56.00<br />
Rubber❸ KC F4 L20N 50.00 KN F4 L20N 59.00<br />
❶ Ø19x5mm = Ø0.75x0.2in<br />
❷ Ø50x10mm = Ø1.97x0.39in<br />
❸ Ø50x10mm = Ø1.97x0.39in off alignment<br />
❹ Direct (positive-guided) opening operation<br />
IEC/EN 60947-5-1.<br />
; safety function per<br />
8-9<br />
General characteristics<br />
The LOVATO ELECTRIC limit switches have been<br />
designed to satisfy requirements for quick installation,<br />
wiring ease, simple setup, modularity, sturdiness and<br />
reliability.<br />
The body cover is hinged at the bottom and removable.<br />
The innovative locking bayonet mechanism provides for<br />
easy removal and repositioning of the operating head in<br />
the required configuration without tools.<br />
The auxiliary contact blocks are removable assuring<br />
wiring simplicity. The heads are made of metal while the<br />
body housing of self-extinguishing polymer<br />
thermoplastic for the KC types or of<br />
aluminum-zinc alloy (zama) for the KN types.<br />
Operational characteristics<br />
– Maximum operating rate: 3600 cycles/h<br />
– Switching time: 0.5-1.5m/s<br />
– Mechanical life: >10 million cycles<br />
– Conventional thermal current Ith: 10A<br />
– UL designation:<br />
• A600 Q300 for KC types<br />
• A300 Q300 for KN types<br />
– Rated insulation voltage Ui:<br />
• 690VAC for KC types<br />
• 440VAC for KN types<br />
– Rated impulse withstand voltage Uimp:<br />
• 6kV for KC types<br />
• 4kV for KN types<br />
– Class II insulation for KC only<br />
– Contact resistance:
8<br />
8-10<br />
Ceramic rod lever<br />
KB H - KM H<br />
KC H - KN H<br />
1 /2 NPT ENTRY<br />
For types with M20 entry,<br />
remove the letter N at the end of the<br />
catalog number.<br />
E.g. KB H1 S11<br />
Limit, micro and foot switches<br />
Limit switches, K series<br />
One bottom entry. Two side entries<br />
Contacts Rod Catalog number<br />
material Plastic Metal<br />
body Price body Price<br />
$ each $ each<br />
One bottom entry. Dimensions to EN 50047.<br />
1NO+1NC Ceramic KB H1 S11N 52.00 KM H1 S11N 62.00<br />
Snap action❶<br />
2NC Ceramic KB H1 S02N 61.00 KM H1 S02N 70.00<br />
Snap action❶<br />
1NO+1NC Ceramic KB H1 A11N 51.00 KM H1 A11N 60.00<br />
Slow break make<br />
before break❶<br />
1NO+1NC Ceramic KB H1 L11N 51.00 KM H1 L11N 60.00<br />
Slow break❶<br />
2NC Ceramic KB H1 L02N 52.00 KM H1 L02N 62.00<br />
Slow break❶<br />
2NO Ceramic KB H1 L20N 52.00 KM H1 L20N 62.00<br />
Slow break<br />
1NO+2NC Ceramic KB H1 L12N 64.00 KM H1 L12N 73.00<br />
Slow break❶<br />
2NO+1NC Ceramic KB H1 L21N 64.00 KM H1 L21N 73.00<br />
Slow break❶<br />
3NC Ceramic KB H1 L03N 64.00 KM H1 L03N 73.00<br />
Slow break❶<br />
Two side entries. Dimensions compatible to EN 50047.<br />
1NO+1NC Ceramic KC H1 S11N 58.00 KN H1 S11N 66.00<br />
Snap action❶<br />
2NC Ceramic KC H1 S02N 67.00 KN H1 S02N 75.00<br />
Snap action❶<br />
1NO+1NC Ceramic KC H1 A11N 56.00 KN H1 A11N 64.00<br />
Slow break make<br />
before break❶<br />
1NO+1NC Ceramic KC H1 L11N 56.00 KN H1 L11N 64.00<br />
Slow break❶<br />
2NC Ceramic KC H1 L02N 58.00 KN H1 L02N 66.00<br />
Slow break❶<br />
2NO Ceramic KC H1 L20N 58.00 KN H1 L20N 66.00<br />
Slow break<br />
❶ Direct (positive-guided) opening operation ; safety function per<br />
IEC/EN 60947-5-1.<br />
electric<br />
General characteristics<br />
The LOVATO ELECTRIC limit switches have been<br />
designed to satisfy requirements FOR quick installation,<br />
wiring ease, simple setup, modularity, sturdiness and<br />
reliability.<br />
The body cover is hinged at the bottom and removable.<br />
The innovative locking bayonet mechanism provides for<br />
easy removal and repositioning of the operating head in<br />
the required configuration without tools. The heads have<br />
axial rotation of 45° angles.<br />
The auxiliary contact blocks are removable assuring<br />
wiring simplicity. The heads are made of metal while the<br />
body housing of self-extinguishing polymer<br />
thermoplastic for the KB and KC types or of<br />
aluminum-zinc alloy (zama) for the KM and KN types.<br />
Operational characteristics<br />
– Maximum operating rate: 3600 cycles/h<br />
– Switching time: 0.5-1.5m/s<br />
– Mechanical life: >10 million cycles<br />
– Conventional thermal current Ith: 10A<br />
– UL designation:<br />
• A600 Q300 for KB-KC types<br />
• A300 Q300 for KM-KN types<br />
– Rated insulation voltage Ui:<br />
• 690VAC for KB-KC types<br />
• 440VAC for KM-KN types<br />
– Rated impulse withstand voltage Uimp:<br />
• 6kV for KB-KC types<br />
• 4kV for KM-KN types<br />
– Class II insulation for KB-KC only<br />
– Contact resistance:
electric<br />
Adjustable rod lever<br />
KB L - KM L<br />
KC L - KN L<br />
Limit, micro and foot switches<br />
Limit switches, K series<br />
One bottom entry. Two side entries<br />
Contacts Rod Catalog number<br />
material Plastic Metal<br />
body Price body Price<br />
$ each $ each<br />
One bottom entry. Dimensions to EN 50047.<br />
1NO+1NC Plastic KB L1 S11N 39.00 KM L1 S11N 48.00<br />
Snap action❶ Metal KB L2 S11N 39.00 KM L2 S11N 48.00<br />
2NC Plastic KB L1 S02N 48.00 KM L1 S02N 57.00<br />
Snap action❶ Metal KB L2 S02N 48.00 KM L2 S02N 57.00<br />
1NO+1NC Plastic KB L1 A11N 37.00 KM L1 A11N 46.00<br />
Slow break make<br />
before break❶<br />
Metal KB L2 A11N 37.00 KM L2 A11N 46.00<br />
1NO+1NC Plastic KB L1 L11N 37.00 KM L1 L11N 46.00<br />
Slow break❶ Metal KB L2 L11N 37.00 KM L2 L11N 46.00<br />
2NC Plastic KB L1 L02N 39.00 KM L1 L02N 48.00<br />
Slow break❶ Metal KB L2 L02N 39.00 KM L2 L02N 48.00<br />
2NO Plastic KB L1 L20N 39.00 KM L1 L20N 48.00<br />
Slow break Metal KB L2 L20N 39.00 KM L2 L20N 48.00<br />
1NO+2NC Plastic KB L1 L12N 50.00 KM L1 L12N 59.00<br />
Slow break❶ Metal KB L2 L12N 50.00 KM L2 L12N 59.00<br />
2NO+1NC Plastic KB L1 L21N 50.00 KM L1 L21N 59.00<br />
Slow break❶ Metal KB L2 L21N 50.00 KM L2 L21N 59.00<br />
3NC Plastic KB L1 L03N 50.00 KM L1 L03N 59.00<br />
Slow break❶ Metal KB L2 L03N 50.00 KM L2 L03N 59.00<br />
Two side entries. Dimensions compatible to EN 50047.<br />
1NO+1NC Plastic KC L1 S11N 44.00 KN L1 S11N 52.00<br />
Snap action❶ Metal KC L2 S11N 44.00 KN L2 S11N 52.00<br />
2NC Plastic KC L1 S02N 53.00 KN L1 S02N 61.00<br />
Snap action❶ Metal KC L2 S02N 53.00 KN L2 S02N 61.00<br />
1NO+1NC Plastic KC L1 A11N 42.00 KN L1 A11N 50.00<br />
Slow break make<br />
before break❶<br />
Metal KC L2 A11N 42.00 KN L2 A11N 50.00<br />
1NO+1NC Plastic KC L1 L11N 42.00 KN L1 L11N 50.00<br />
Slow break❶ Metal KC L2 L11N 42.00 KN L2 L11N 50.00<br />
2NC Plastic KC L1 L02N 44.00 KN L1 L02N 52.00<br />
Slow break❶ Metal KC L2 L02N 44.00 KN L2 L02N 52.00<br />
2NO Plastic KC L1 L20N 44.00 KN L1 L20N 52.00<br />
Slow break Metal KC L2 L20N 44.00 KN L2 L20N 52.00<br />
BI-DIRECTIONAL.<br />
1 /2 NPT ENTRY<br />
One bottom entry. Dimensions to EN 50047.<br />
For types with M20 entry,<br />
2NC❶ Plastic KB L1 D02N 54.00 KM L1 D02N 60.00<br />
remove the letter N at the end of the<br />
catalog number.<br />
Independent Metal KB L2 D02N 54.00 KM L2 D02N 60.00<br />
E.g. KB L1 S11 ❶ Direct (positive-guided) opening operation ; safety function per<br />
IEC/EN 60947-5-1.<br />
8-11<br />
General characteristics<br />
The LOVATO ELECTRIC limit switches have been<br />
designed to satisfy requirements for quick installation,<br />
wiring ease, simple setup, modularity, sturdiness and<br />
reliability.<br />
The body cover is hinged at the bottom and removable.<br />
The innovative locking bayonet mechanism provides for<br />
easy removal and repositioning of the operating head in<br />
the required configuration without tools.<br />
The auxiliary contact blocks are removable assuring<br />
wiring simplicity. The heads are made of metal while the<br />
body housing of self-extinguishing polymer<br />
thermoplastic for the KB and KC types or of<br />
aluminum-zinc alloy (zama) for the KM and KN types.<br />
Operational characteristics<br />
– Maximum operating rate: 3600 cycles/h<br />
– Switching time: 0.5-1.5m/s<br />
– Mechanical life: >10 million cycles<br />
– Conventional thermal current Ith: 10A<br />
– UL designation:<br />
• A600 Q300 for KB-KC types<br />
• A300 Q300 for KM-KN types<br />
– Rated insulation voltage Ui:<br />
• 690VAC for KB-KC types<br />
• 440VAC for KM-KN types<br />
– Rated impulse withstand voltage Uimp:<br />
• 6kV for KB-KC types<br />
• 4kV for KM-KN types<br />
– Class II insulation for KB-KC only<br />
– Contact resistance:
8<br />
8-12<br />
Wobble stick,<br />
omnidirectional<br />
KB M - KM M<br />
KC M - KN M<br />
1 /2 NPT ENTRY<br />
For types with M20 entry,<br />
remove the letter N at the end of the<br />
catalog number.<br />
E.g. KB M1 S11<br />
Limit, micro and foot switches<br />
Limit switches, K series<br />
One bottom entry. Two side entries<br />
Contacts Rod Catalog number<br />
material Plastic Metal<br />
body Price body Price<br />
$ each $ each<br />
One bottom entry. Dimensions to EN 50047.<br />
1NO+1NC Plastic KB M1 S11N 38.00 KM M1 S11N 47.00<br />
Snap action Metal KB M2 S11N 36.00 KM M2 S11N 45.00<br />
2NC Plastic KB M1 S02N 47.00 KM M1 S02N 56.00<br />
Snap action Metal KB M2 S02N 44.00 KM M2 S02N 53.00<br />
1NO+1NC Plastic KB M1 A11N 36.00 KM M1 A11N 45.00<br />
Slow break make Metal KB M2 A11N 34.00 KM M2 A11N 43.00<br />
before break<br />
1NO+1NC Plastic KB M1 L11N 36.00 KM M1 L11N 45.00<br />
Slow break Metal KB M2 L11N 34.00 KM M2 L11N 43.00<br />
2NC Plastic KB M1 L02N 38.00 KM M1 L02N 4700<br />
Slow break Metal KB M2 L02N 36.00 KM M2 L02N 45.00<br />
2NO Plastic KB M1 L20N 38.00 KM M1 L20N 47.00<br />
Slow break Metal KB M2 L20N 36.00 KM M2 L20N 45.00<br />
1NO+2NC Plastic KB M1 L12N 49.00 KM M1 L12N 58.00<br />
Slow break Metal KB M2 L12N 47.00 KM M2 L12N 56.00<br />
2NO+1NC Plastic KB M1 L21N 49.00 KM M1 L21N 58.00<br />
Slow break Metal KB M2 L21N 47.00 KM M2 L21N 56.00<br />
3NC Plastic KB M1 L03N 49.00 KM M1 L03N 58.00<br />
Slow break Metal KB M2 L03N 47.00 KM M2 L03N 56.00<br />
Two side entries. Dimensions compatible to EN 50047.<br />
1NO+1NC Plastic KC M1 S11N 43.00 KN M1 S11N 52.00<br />
Snap action Metal KC M2 S11N 41.00 KN M2 S11N 49.00<br />
2NC Plastic KC M1 S02N 52.00 KN M1 S02N 60.00<br />
Snap action Metal KC M2 S02N 49.00 KN M2 S02N 58.00<br />
1NO+1NC Plastic KC M1 A11N 41.00 KN M1 A11N 49.00<br />
Slow break make Metal KC M2 A11N 38.00 KN M2 A11N 47.00<br />
before break<br />
1NO+1NC Plastic KC M1 L11N 41.00 KN M1 L11N 49.00<br />
Slow break Metal KC M2 L11N 38.00 KN M2 L11N 47.00<br />
2NC Plastic KC M1 L02N 43.00 KN M1 L02N 52.00<br />
Slow break Metal KC M2 L02N 41.00 KN M2 L02N 49.00<br />
2NO Plastic KC M1 L20N 43.00 KN M1 L20N 52.00<br />
Slow break Metal KC M2 L20N 41.00 KN M2 L20N 49.00<br />
electric<br />
General characteristics<br />
The LOVATO ELECTRIC limit switches have been<br />
designed to satisfy requirements for quick installation,<br />
wiring ease, simple setup, modularity, sturdiness and<br />
reliability.<br />
The body cover is hinged at the bottom and removable.<br />
The innovative locking bayonet mechanism provides for<br />
easy removal and repositioning of the operating head in<br />
the required configuration without tools.<br />
The auxiliary contact blocks are removable assuring<br />
wiring simplicity. The heads are made of metal while the<br />
body housing of self-extinguishing polymer<br />
thermoplastic for the KB and KC types or of<br />
aluminum-zinc alloy (zama) for the KM and KN types.<br />
Operational characteristics<br />
– Maximum operating rate: 3600 cycles/h<br />
– Switching time: 0.5-1.5m/s<br />
– Mechanical life: >10 million cycles<br />
– Conventional thermal current Ith: 10A<br />
– UL designation:<br />
• A600 Q300 for KB-KC types<br />
• A300 Q300 for KM-KN types<br />
– Rated insulation voltage Ui:<br />
• 690VAC for KB-KC types<br />
• 440VAC for KM-KN types<br />
– Rated impulse withstand voltage Uimp:<br />
• 6kV for KB-KC types<br />
• 4kV for KM-KN types<br />
– Class II insulation for KB-KC only<br />
– Contact resistance:
electric<br />
Limit, micro and foot switches<br />
Limit switches, K series<br />
One bottom entry. Two side entries<br />
8-13<br />
Hinge operating Contacts Shaft Catalog number<br />
features Plastic Metal<br />
body Price body Price<br />
KB P - KM P<br />
KC P - KN P<br />
1 /2 NPT ENTRY<br />
For types with M20 entry,<br />
remove the letter N at the end of the<br />
catalog number.<br />
E.g. KB Q1 L11<br />
$ each $ each<br />
One bottom entry. Dimensions to EN 50047.<br />
1NO+1NC Short KB P1 L11N 70.00 KM P1 L11N 79.00<br />
Slow break❶ cylinder<br />
1NO+1NC Long KB P2 L11N 73.00 KM P2 L11N 82.00<br />
Slow break❶ solid<br />
1NO+1NC Long KB P3 L11N 73.00 KM P3 L11N 82.00<br />
Slow break❶ solid w/<br />
reduction<br />
2NC Short KB P1 L02N 72.00 KM P1 L02N 81.00<br />
Slow break❶ cylinder<br />
2NC Long KB P2 L02N 75.00 KM P2 L02N 84.00<br />
Slow break❶ solid<br />
2NC Long KB P3 L02N 75.00 KM P3 L02N 84.00<br />
Slow break❶ solid w/<br />
reduction<br />
1NO+2NC Short KB P1 L12N 83.00 KM P1 L12N 92.00<br />
Slow break❶ cylinder<br />
1NO+2NC Long KB P2 L12N 86.00 KM P2 L12N 96.00<br />
Slow break❶ solid<br />
1NO+2NC Long KB P3 L12N 86.00 KM P3 L12N 96.00<br />
Slow break❶ solid w/<br />
reduction<br />
2NO+1NC Short KB P1 L21N 83.00 KM P1 L21N 92.00<br />
Slow break❶ cylinder<br />
2NO+1NC Long KB P2 L21N 86.00 KM P2 L21N 96.00<br />
Slow break❶ solid<br />
2NO+1NC Long KB P3 L21N 86.00 KM P3 L21N 96.00<br />
Slow break❶ solid w/<br />
reduction<br />
3NC Short KB P1 L03N 83.00 KM P1 L03N 92.00<br />
Slow break❶ cylinder<br />
3NC Long KB P2 L03N 86.00 KM P2 L03N 96.00<br />
Slow break❶ solid<br />
3NC Long KB P3 L03N 86.00 KM P3 L03N 96.00<br />
Slow break❶ solid w/<br />
reduction<br />
Two side entries. Dimensions compatible to EN 50047.<br />
1NO+1NC Short KC P1 L11N 76.00 KN P1 L11N 84.00<br />
Slow break❶ cylinder<br />
2NC Long KC P2 L11N 79.00 KN P2 L11N 88.00<br />
Slow break❶ solid<br />
1NO+1NC Long KC P3 L11N 79.00 KN P3 L11N 88.00<br />
Slow break❶ solid w/<br />
reduction<br />
2NC Short KC P1 L02N 78.00 KN P1 L02N 86.00<br />
Slow break❶ cylinder<br />
2NC Long KC P2 L02N 81.00 KN P2 L02N 90.00<br />
Slow break❶ solid<br />
2NC Long KC P3 L02N 81.00 KN P3 L02N 90.00<br />
Slow break❶ solid w/<br />
reduction<br />
❶ Direct (positive-guided) opening operation ; safety function per<br />
IEC/EN 60947-5-1.<br />
General characteristics<br />
The LOVATO ELECTRIC limit switches have been<br />
designed to satisfy requirements for quick installation,<br />
wiring ease, simple setup, modularity, sturdiness and<br />
reliability.<br />
The body cover is hinged at the bottom and removable.<br />
The innovative locking bayonet mechanism provides for<br />
easy removal and repositioning of the operating head in<br />
the required configuration without tools. The heads have<br />
axial rotation of 45° angles.<br />
The auxiliary contact blocks are removable assuring<br />
wiring simplicity. The heads are made of metal while the<br />
body housing of self-extinguishing polymer<br />
thermoplastic for the KB and KC types or of<br />
aluminum-zinc alloy (zama) for the KM and KN types.<br />
Operational characteristics<br />
– Maximum operating rate: 3600 cycles/h<br />
– Switching time: 0.5-1.5m/s<br />
– Mechanical life: >10 million cycles<br />
– Conventional thermal current Ith: 10A<br />
– UL designation:<br />
• A600 Q300 for KB-KC types<br />
• A300 Q300 for KM-KN types<br />
– Rated insulation voltage Ui:<br />
• 690VAC for KB-KC types<br />
• 440VAC for KM-KN types<br />
– Rated impulse withstand voltage Uimp:<br />
• 6kV for KB-KC types<br />
• 4kV for KM-KN types<br />
– Class II insulation for KB-KC only<br />
– Contact resistance:
8<br />
8-14<br />
Slotted lever<br />
KB Q - KM Q<br />
KC Q - KN Q<br />
Limit, micro and foot switches<br />
Limit switches, K series<br />
One bottom entry. Two side entries<br />
Contacts<br />
Catalog number<br />
Plastic<br />
Metal<br />
body Price body Price<br />
$ each $ each<br />
One bottom entry. Dimensions to EN 50047.<br />
1NO+1NC Slow break❶ KB Q1 L11N 63.00 KM Q1 L11N 72.00<br />
2NC Slow break❶ KB Q1 L02N 65.00 KM Q1 L02N 74.00<br />
1NO+2NC Slow break❶ KB Q1 L12N 76.00 KM Q1 L12N 85.00<br />
2NO+1NC Slow break❶ KB Q1 L21N 76.00 KM Q1 L21N 85.00<br />
3NC Slow break❶ KB Q1 L03N 76.00 KM Q1 L03N 85.00<br />
Two side entries. Dimensions compatible to EN 50047.<br />
1NO+1NC Slow break❶ KC Q1 L11N 69.00 KN Q1 L11N 77.00<br />
2NC Slow break❶ KC Q1 L02N 71.00 KN Q1 L02N 80.00<br />
❶ Direct (positive-guided) opening operation<br />
IEC/EN 60947-5-1.<br />
; safety function per<br />
electric<br />
General characteristics<br />
The LOVATO ELECTRIC limit switches have been<br />
designed to satisfy requirements for quick installation,<br />
wiring ease, simple setup, modularity, sturdiness and<br />
reliability.<br />
The body cover is hinged at the bottom and removable.<br />
The innovative locking bayonet mechanism provides for<br />
easy removal and repositioning of the operating head in<br />
the required configuration without tools. The heads have<br />
axial rotation of 45° angles.<br />
The auxiliary contact blocks are removable assuring<br />
wiring simplicity. The heads are made of metal while the<br />
body housing of self-extinguishing polymer<br />
thermoplastic for the KB and KC types or of<br />
aluminum-zinc alloy (zama) for the KM and KN types.<br />
Operational characteristics<br />
– Maximum operating rate: 3600 cycles/h<br />
– Switching time: 0.5-1.5m/s<br />
– Mechanical life: >10 million cycles<br />
– Conventional thermal current Ith: 10A<br />
– UL designation:<br />
• A600 Q300 for KB-KC types<br />
• A300 Q300 for KM-KN types<br />
– Rated insulation voltage Ui:<br />
• 690VAC for KB-KC types<br />
• 440VAC for KM-KN types<br />
– Rated impulse withstand voltage Uimp:<br />
• 6kV for KB-KC types<br />
• 4kV for KM-KN types<br />
– Class II insulation for KB-KC only<br />
– Contact resistance:
electric<br />
Key operated<br />
KB N1 L11N<br />
KC N1 L02N<br />
1 /2 NPT ENTRY<br />
For types with M20 entry,<br />
remove the letter N at the end of the<br />
catalog number.<br />
E.g. KB N1 L11<br />
Limit, micro and foot switches<br />
Limit switches, K series<br />
One bottom entry. Two side entries<br />
Contacts Key Catalog Price<br />
shape❷ number<br />
Plastic body<br />
$ each<br />
One bottom entry. Dimensions to EN 50047.<br />
1NO+1NC Straight KB N1 L11N 64.00<br />
Slow break❶ Angled KB N2 L11N 64.00<br />
Straight “T” KB N3 L11N 63.00<br />
Angled “T” KB N4 L11N 63.00<br />
2NC Straight KB N1 L02N 66.00<br />
Slow break❶ Angled KB N2 L02N 66.00<br />
Straight “T” KB N3 L02N 65.00<br />
Angled “T” KB N4 L02N 65.00<br />
1NO+2NC Straight KB N1 L12N 77.00<br />
Slow break❶ Angled KB N2 L12N 77.00<br />
Straight “T” KB N3 L12N 76.00<br />
Angled “T” KB N4 L12N 76.00<br />
2NO+1NC Straight KB N1 L21N 77.00<br />
Slow break❶ Angled KB N2 L21N 77.00<br />
Straight “T” KB N3 L21N 76.00<br />
Angled “T” KB N4 L21N 76.00<br />
3NC Straight KB N1 L03N 77.00<br />
Slow break❶ Angled KB N2 L03N 77.00<br />
Straight “T” KB N3 L03N 76.00<br />
Angled “T” KB N4 L03N 76.00<br />
Two side entries. Dimensions compatible to EN 50047.<br />
1NO+1NC Straight KC N1 L11N 70.00<br />
Slow break❶ Angled KC N2 L11N 70.00<br />
Straight “T” KC N3 L11N 68.00<br />
Angled “T” KC N4 L11N 68.00<br />
2NC Straight KC N1 L02N 72.00<br />
Slow break❶ Angled KC N2 L02N 72.00<br />
Straight “T” KC N3 L02N 71.00<br />
Angled “T” KC N4 L02N 71.00<br />
❶ Direct (positive-guided) opening operation ; safety function per<br />
IEC/EN 60947-5-1.<br />
❷ The key is standard supplied.<br />
8-15<br />
General characteristics<br />
The LOVATO ELECTRIC limit switches have been<br />
designed to satisfy requirements for quick installation,<br />
wiring ease, simple setup, modularity, sturdiness and<br />
reliability.<br />
The body cover is hinged at the bottom and removable.<br />
The heads have axial rotation in any of 4 positions at 90°<br />
angles.<br />
The auxiliary contact blocks are removable assuring<br />
wiring simplicity. The heads are made of metal while the<br />
body housing of self-extinguishing polymer<br />
thermoplastic.<br />
Operational characteristics<br />
– Maximum operating rate: 3600 cycles/h<br />
– Switching time: 0.5-1.5m/s<br />
– Mechanical life: >10 million cycles<br />
– Conventional thermal current Ith: 10A<br />
– UL designation: A600 Q600<br />
– Rated insulation voltage Ui: 690V<br />
– Rated impulse withstand voltage Uimp: 6kV<br />
– Class II insulation<br />
– Contact resistance:
8<br />
8-16<br />
Auxiliary contact<br />
blocks<br />
K X B S02<br />
K X B L03<br />
Body complete with<br />
auxiliary contacts<br />
KX CB - KX CM<br />
KX CC - KX CN<br />
1 /2 NPT ENTRY<br />
For types with M20 entry,<br />
remove the letter N at the end of the<br />
catalog number.<br />
E.g. KB Q1 L11<br />
Forward travel of snap action contacts<br />
Return travel of snap action contacts<br />
KX ... S11<br />
KX ... S02<br />
KX ... A11<br />
KX ... L11<br />
open<br />
closed<br />
21-22<br />
13-14<br />
21-22<br />
13-14<br />
0 0.5 2.3 6mm<br />
(0.02in) (0.09in) (0.24in)<br />
11-12<br />
21-22<br />
11-12<br />
21-22<br />
0 0.5 2.3 6mm<br />
(0.02in) (0.09in) (0.24in)<br />
13-14<br />
21-22<br />
0 1.1 2.1 6mm<br />
(0.04in) (0.08in)<br />
(0.24in)<br />
13-14<br />
21-22<br />
0 2.1 2.9 6mm<br />
(0.08in) (0.11in) (0.24in)<br />
Limit, micro and foot switches<br />
Accessories and spare parts<br />
for KB, KC, KM and KN limit switches<br />
Contacts<br />
Catalog number Price<br />
$ each<br />
1NO+1NC Snap action❶❷ KX B S11 15.70<br />
2NC Snap action❶❷ KX B S02 24.90<br />
1NO+1NC Slow break, make before break❶❷ KX B A11 13.50<br />
1NO+1NC Slow break❷ KX B L11 13.50<br />
2NC Slow break❷ KX B L02 15.70<br />
2NO Slow break KX B L20 15.70<br />
1NO+2NC Slow break❷❸ KX B L12 27.70<br />
2NO+1NC Slow break❷❸ KX B L21 27.70<br />
3NC Slow break❷❸ KX B L03 27.70<br />
❶ Not suitable for key operated KBN / KCN, hinged operating KBP / KCP / KMP /<br />
KNP and slotted lever KBQ / KCQ / KMQ / KNQ types.<br />
❷ Direct (positive-guided) opening operation ; safety function per<br />
IEC/EN 60947-5-1.<br />
❸ Not suitable for KC and KN types.<br />
Contacts<br />
Catalog number<br />
Plastic<br />
Metal<br />
body Price body Price<br />
$ each $ each<br />
One bottom entry. Dimensions to EN 50047.<br />
1NO+1NC Snap action❶❷ KX CB S11N 21.90 KX CM S11N 30.90<br />
2NC Snap action❶❷ KX CB S02N 30.40 KX CM S02N 39.40<br />
1NO+1NC Slow break, KX CB A11N 19.90 KX CM A11N 28.90<br />
make before break❶❷<br />
1NO+1NC Slow break❷ KX CB L11N 19.90 KX CM L11N 28.90<br />
2NC Slow break❷ KX CB L02N 21.90 KX CM L02N 30.90<br />
2NO Slow break KX CB L20N 21.90 KX CM L20N 30.90<br />
1NO+2NC Slow break❷❸ KX CB L12N 32.90 KX CM L12N 41.90<br />
2NO+1NC Slow break❷❸ KX CB L21N 32.90 KX CM L21N 41.90<br />
3NC Slow break❷❸ KX CB L03N 32.90 KX CM L03N 41.90<br />
Two side entries. Dimensions compatible to EN 50047.<br />
1NO+1NC Snap action❶❷ KX CC S11N 26.00 KX CN S11N 34.00<br />
2NC Snap action❶❷ KX CC S02N 35.00 KX CN S02N 43.00<br />
1NO+1NC Slow break, KX CC A11N 24.00 KX CN A11N 32.00<br />
make before break❶❷<br />
1NO+1NC Slow break❷ KX CC L11N 24.00 KX CN L11N 32.00<br />
2NC Slow break❷ KX CC L02N 26.00 KX CN L02N 34.00<br />
2NO Slow break KX CC L20N 26.00 KX CN L20N 34.00<br />
❶ Not suitable for key operated KBN / KCN, hinged operating KBP / KCP / KMP /<br />
KNP and slotted lever KBQ / KCQ / KMQ / KNQ types.<br />
❷ Direct (positive-guided) opening operation ; safety function per<br />
IEC/EN 60947-5-1.<br />
❸ Not suitable for KC and KN types.<br />
KX ... L02<br />
KX ... L20<br />
KX ... L12<br />
KX ... L21<br />
KX ... L03<br />
11-12<br />
21-22<br />
0 2.1 6mm<br />
(0.08in)<br />
(0.24in)<br />
13-14<br />
23-24<br />
0 2.1 6mm<br />
(0.08in)<br />
(0.24in)<br />
21-22<br />
31-32<br />
13-14<br />
0 2.2 2.7 6mm<br />
(0.08in) (0.11in)<br />
(0.24in)<br />
21-22<br />
13-14<br />
33-34<br />
0 2.2 2.7 6mm<br />
(0.08in) (0.11in)<br />
(0.24in)<br />
11-12<br />
21-22<br />
31-32<br />
0 2.2 6mm<br />
(0.08in)<br />
(0.24in)<br />
electric<br />
General characteristics<br />
The KX B contact blocks can be used with KB, KC, KM<br />
and KN limit switches. Combinations of 2 contacts with<br />
slow-break or snap action and 3 slow-break contacts, for<br />
KB and KM types only, are available.<br />
The NC contacts have direct opening operation, a<br />
specific safety principle.<br />
The particular four-point contacts warrant high<br />
conductivity in any sort of application. The removal of<br />
the contacts from the limit switch body provides wiring<br />
ease and reduces installation time as well.<br />
The KX C... bodies, complete with auxiliary contacts, can<br />
be used as spare parts for the KB, KC, KM and KN limit<br />
switches or coupled with the KX A... operating heads, to<br />
obtain complete limit switches in the required<br />
configurations.<br />
The body cover is hinged at the bottom and removable<br />
to have the best access. Each body includes the<br />
innovative locking bayonet mechanism of the operating<br />
head. Plastic and metal types are available.<br />
Operational characteristics<br />
– Mechanical life: >10 million cycles<br />
– Conventional thermal current Ith: 10A<br />
– UL designation:<br />
• A600 Q300 for KX CB-KX CC types<br />
• A300 Q300 for KX CM-KX CN types<br />
– Rated insulation voltage Ui:<br />
• 690VAC for KX CB-KX CC types<br />
• 440VAC for KX CM-KX CN types<br />
– Rated impulse withstand voltage Uimp:<br />
• 6kV for KX CB-KX CC types<br />
• 4kV for KX CM-KX CN types<br />
– Class II insulation for KX CB-KX CC only<br />
– Contact resistance:
electric<br />
Limit, micro and foot switches<br />
Accessories and spare parts<br />
for KB, KC, KM and KN limit switches<br />
8-17<br />
Operating heads Description Catalog number Price<br />
KX A A1 KX A B1 KX A B2<br />
KX A C1<br />
KX A D1<br />
KX A C2<br />
KX A D2<br />
KX A E1 KX A E2 KX A E3<br />
$ each<br />
Top push rod plunger KX A A1 7.30<br />
Plastic top roller push plunger KX A B1 11.30<br />
Metal top roller push plunger KX A B2 13.00<br />
Plastic roller centre push lever KX A C1 12.10<br />
Metal roller centre push lever KX A C2 13.40<br />
Plastic roller side push lever KX A D1 12.10<br />
Metal roller side push lever KX A D2 13.40<br />
Plastic roller lever plunger KX A E1 13.70<br />
Metal roller lever plunger KX A E2 16.30<br />
Rubber Ø50x10mm (1.97x0.34in) KX A E3 20.20<br />
roller lever plunger<br />
Adjustable plastic roller lever KX A F1 15.30<br />
Adjustable metal roller lever KX A F2 18.00<br />
Adjustable rubber Ø50x10mm KX A F3 21.30<br />
(1.97x0.34in) roller lever<br />
Adjustable offset rubber KX A F4 23.20<br />
Ø50x10mm (1.97x0.34in) roller<br />
lever<br />
Ceramic rod lever KX A H1 30.70<br />
Adjustable plastic rod lever KX A L1 17.20<br />
Adjustable metal rod lever KX A L2 17.20<br />
Flexible wobble stick KX A M1 16.50<br />
Semirigid wobble stick KX A M2 14.00<br />
General characteristics<br />
The KX A operating heads can be used as spare parts for<br />
the KB, KC, KM and KN limit switches or coupled with<br />
the KX C bodies to obtain complete limit switches in the<br />
required configurations.<br />
The heads are made of metal, providing sturdiness and<br />
operating reliability in all conditions.<br />
The shape of the coupling section with the body of the<br />
KB, KC, KM and KN switches allows for orientation of<br />
the head in any 45° angle position while the initial level<br />
and rod position can be adjusted 360° at 15° angle<br />
positions.<br />
The head fixing to the body is achieved by the innovative<br />
locking bayonet mechanism so there is no need for<br />
tools.<br />
8<br />
KX A F1<br />
KX A F2<br />
KX A F3 KX A F4 KX A H1<br />
KX A L1 KX A L2 KX A M1 KX A M2<br />
Accessories Description Catalog number Price<br />
$ each<br />
M20 cable gland KX P01 1.50<br />
PG13.5 cable gland KX P02 1.50<br />
M20 rubber grommet KX P03 1.00<br />
KX P... KX P03<br />
General characteristics for cable glands<br />
The cable glands are in plastic with either M20 or PG13.5<br />
thread and provide to keep the cable in place and<br />
maintain the proper IP protection of the limit switch after<br />
installation.<br />
Operational characteristics for cable glands<br />
– Material: Self-extinguishing polyamide<br />
– Degree of protection: IP68<br />
– Gland seal with wire diameter: 6-12mm / 0.24-0.47 in.<br />
Certifications and compliance for cable glands<br />
UL listed for USA and Canada, file E93601.<br />
Compliant with standards: EN 50262.<br />
Dimensions<br />
pages D-21 and 22<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com
8<br />
8-18<br />
Prewired limit<br />
switches<br />
KP A1<br />
KP B1<br />
KP B3<br />
KP B5<br />
KP B7<br />
KP A2<br />
KP B2<br />
KP B4<br />
KP B6<br />
KP B8<br />
Limit, micro and foot switches<br />
KP types prewired metal limit switches<br />
Dimensions compatible to EN 50047<br />
Contacts Catalog Price<br />
number❻<br />
$ each<br />
Top push metal rod plunger.<br />
1NO+1NC Snap action❶ KP A1 S11 55.90<br />
1NO+1NC Slow break❶ KP A1 L11 55.90<br />
Top plastic roller push plunger.<br />
1NO+1NC Snap action❶ KP B1 S11 60.20<br />
1NO+1NC Slow break❶ KP B1 L11 60.20<br />
1NO+1NC Snap action❶ KP B3 S11❷ 60.20<br />
1NO+1NC Slow break❶ KP B3 L11❷ 60.20<br />
Top metal roller push plunger.<br />
1NO+1NC Snap action❶ KP B2 S11 62.30<br />
1NO+1NC Slow break❶ KP B2 L11 62.30<br />
1NO+1NC Snap action❶ KP B4 S11❷ 62.30<br />
1NO+1NC Slow break❶ KP B4 L11❷ 62.30<br />
M12 fixing head. Top push metal rod plunger.<br />
1NO+1NC Snap action❶ KP A2 S11 58.80<br />
1NO+1NC Slow break❶ KP A2 L11 58.80<br />
M12 fixing head. Top plastic roller push plunger.<br />
1NO+1NC Snap action❶ KP B5 S11 63.10<br />
1NO+1NC Slow break❶ KP B5 L11 63.10<br />
1NO+1NC Snap action❶ KP B7 S11❷ 63.10<br />
1NO+1NC Slow break❶ KP B7 L11❷ 63.10<br />
M12 fixing head. Top plastic roller push plunger.<br />
1NO+1NC Snap action❶ KP B6 S11 64.80<br />
1NO+1NC Slow break❶ KP B6 L11 64.80<br />
1NO+1NC Snap action❶ KP B8 S11❷ 64.80<br />
1NO+1NC Slow break❶ KP B8 L11❷ 64.80<br />
Roller lever plunger.<br />
1NO+1NC Snap action❶ KP E1 S11❷ 57.20<br />
1NO+1NC Slow break❶ KP E1 L11❷ 57.20<br />
1NO+1NC Snap action❶ KP E1 S11❹ 57.20<br />
1NO+1NC Slow break❶ KP E1 L11❹ 57.20<br />
Adjustable plastic roller rod lever ❺.<br />
1NO+1NC Snap action❶ KP F1 S11 58.50<br />
1NO+1NC Slow break❶ KP F1 L11 58.50<br />
Adjustable metal rod lever.<br />
1NO+1NC Snap action❶ KP L2 S11 60.80<br />
1NO+1NC Slow break❶ KP L2 L11 60.80<br />
Omnidirectional metal rod wobble stick.<br />
1NO+1NC Snap action❶ KP M2 S11 62.10<br />
Forward travel of snap action contacts<br />
Return travel of snap action contacts<br />
open<br />
closed<br />
electric<br />
General characteristics<br />
The prewired metal limit switches come equipped with a<br />
multicore wire connected to the electrical contacts and<br />
firmly fixed to the body by means of resin. As a result,<br />
these limit switches have a combination of unique<br />
features: a very reduced depth - 16mm only - and a<br />
high degree of production - IP67.<br />
They are suitable to detect the position of mobile<br />
mechanisms and parts in many operating conditions,<br />
which can be found in the industrial field. They are<br />
particularly ideal when a high protection degree is<br />
required, for example on machinery and equipment for<br />
outdoor use or where very compact size is essential.<br />
Each can be simply fixed to the machinery by screws,<br />
inserting them in the apposite openings on the switch<br />
body and then connected to the circuit; the different<br />
colors of the cores and the contact scheme on the front<br />
ease wiring as well.<br />
The operating heads have axial rotation while levers are<br />
adjustable and capsizable.<br />
Operational characteristics<br />
– Maximum operating rate: 3600 cy/h<br />
– Mechanical life: >10 million cycles<br />
– Conventional thermal current Ith: 5A<br />
– UL designation: B300 R300<br />
– Rated insulation voltage Ui: 400V<br />
– Rated impulse withstand voltage Uimp: 4kV<br />
– Class 1 insulation<br />
– Contact resistance:
electric<br />
Top push rod plunger<br />
TS1 01 10 - TL1 01 10<br />
Limit, micro and foot switches<br />
T plastic series limit switches<br />
Dimensions to EN 50041<br />
Contacts Plunger Catalog number Price<br />
material<br />
$ each<br />
Without reset button.<br />
1NO+1NC Steel TS1 01 10 54.00<br />
Snap action<br />
1NO+1NC ❶ Steel TL1 01 10 54.00<br />
Slow break<br />
With reset button on front.<br />
1NO+1NC Steel TS2 01 10 64.00<br />
Snap action<br />
1NO+1NC ❶ Steel TL2 01 10 64.00<br />
Slow break<br />
❶ Direct (positive-guided) opening operation ; safety function per<br />
IEC/EN 60947-5-1.<br />
Type<br />
TS1 01 10<br />
TS2 01 10<br />
TL1 01 10<br />
TL2 01 10<br />
TS1 05<br />
TS2 05<br />
TL1 05<br />
TL2 05<br />
Forward travel of snap action contacts<br />
Return travel of snap action contacts<br />
21-22<br />
13-14<br />
21-22<br />
13-14<br />
0 [mm]<br />
8-19<br />
open<br />
closed<br />
6 (0.24in)<br />
21-22<br />
13-14<br />
0 [mm] 6 (0.24in)<br />
21-22<br />
13-14<br />
21-22<br />
13-14<br />
0 60°<br />
21-22<br />
13-14<br />
0 60°<br />
TS2 01 10 - TL2 01 10<br />
Roller lever<br />
TS1 - TL1 05<br />
(Ø 20x5mm)<br />
Contacts Roller Catalog number Price<br />
material<br />
$ each<br />
Without reset button.<br />
1NO+1NC Plastic 20x5 TS1 05 20 A❷ 62.00<br />
Snap action Metal 20x5 TS1 05 21 A 64.00<br />
Rubber 50x10 TS1 05 24 A❸ 66.00<br />
1NO+1NC ❶ Plastic 20x5 TL1 05 20 A❷ 62.00<br />
Slow break Metal 20x5 TL1 05 21 A 64.00<br />
Rubber 50x10 TL1 05 24 A❸ 66.00<br />
With reset button on the left.<br />
1NO+1NC Plastic 20x5 TS2 05 20 AS❷ 72.00<br />
Snap action Metal 20x5 TS2 05 21 AS 74.00<br />
Rubber 50x10 TS2 05 24 AS❸ 76.00<br />
1NO+1NC ❶ Plastic 20x5 TL2 05 20 AS❷ 72.00<br />
Slow break Metal 20x5 TL2 05 21 AS 74.00<br />
Rubber 50x10 TL2 05 24 AS❸ 76.00<br />
❶ Direct (positive-guided) opening operation ; safety function per<br />
IEC/EN 60947-5-1.<br />
❷ Version with Ø30x15mm plastic roller is available; replace 20 with 23 in the<br />
catalg number.<br />
❸ Version with Ø30x15mm rubber roller is available; replace 24 with 22 in the<br />
catalg number.<br />
Roller sizes:<br />
Ø 20x5mm = Ø 0.79x0.2in<br />
Ø 50x10mm = Ø1.97x0.39in<br />
Ø 30x5mm = Ø 1.18x0.2in<br />
Ø 35x15mm = Ø 1.38x0.59in<br />
General characteristics<br />
The TS-TL series limit switches are designed and<br />
manufactured per European standards<br />
EN 50041 for dimensions.<br />
The insulated housing of the limit switch is made of<br />
self-extinguishing thermoplastic giving excellent<br />
mechanical stability and is suitable, as a result, for<br />
assembly on machinery or installations in the<br />
general-purpose industrial field.<br />
The housing sturdiness makes these switches ideal for<br />
use in heavy duty applications.<br />
The double-insulated housing of the limit switch protects<br />
internal circuits against shocks or impacts in industrial<br />
environments, against accidental ingress of tools, and<br />
accidental contact.<br />
The contacts are designed to ensure self cleaning of the<br />
silver-alloy contact surfaces. Contacts (NC) of the TL<br />
series have direct (positive) opening operation to prevent<br />
sticking or welding.<br />
Operational characteristics<br />
– Maximum operating rate: 1200 cy/h<br />
– Switching time: 0.5-1.5m/s<br />
– Mechanical life: >10 million cycles<br />
– Utilization category (UL designation):<br />
• DC13 duty: 1.5A 24V (R150)<br />
• AC15 duty: 6A 250V (B600)<br />
– Conventional thermal current Ith: 6A<br />
– Rated insulation voltage Ui: 250VAC<br />
– Contact resistance:
8-20 Limit, micro and foot switches<br />
electric<br />
T plastic series<br />
Dimensions to EN 50041<br />
Wobble stick,<br />
omnidirectional<br />
Contacts Rod Catalog number Price<br />
material<br />
$ each<br />
Without reset button.<br />
1NO+1NC Flexible TS1 09 92 62.00<br />
Snap action<br />
1NO+1NC Flexible TL1 09 92 62.00<br />
Slow break<br />
Type<br />
TS1 09 92<br />
TL1 09 92<br />
TL2 10<br />
Forward travel of snap action contacts<br />
Return travel of snap action contacts<br />
open<br />
closed<br />
21-22<br />
13-14<br />
21-22<br />
13-14<br />
0 36°<br />
21-22<br />
13-14<br />
0 36°<br />
21-22<br />
13-14<br />
0 [mm] 4.2 (0.17in)<br />
8<br />
TS1 09 92 - TL1 09 92<br />
Key operated<br />
TL2 10<br />
Accessories and<br />
spare parts<br />
Contacts Key Catalog number Price<br />
shape ❷<br />
$ each<br />
Front key withdrawal ❶.<br />
1NO+1NC ❸ Straight TL2 10 10 68.00<br />
Slow break Angled TL2 10 11 68.00<br />
Angled “T” TL2 10 12 68.00<br />
Straight “T” TL2 10 13 68.00<br />
❶ Version with key withdrawal on the left or on the right is available; replace the<br />
last letter (A) of the catalog number respectively with S or D<br />
(e.g. TS2 10 10S - left or TS2 10 10D - right). For further assistance, contact<br />
Sales & Technical Support.<br />
❷ The key is standard supplied.<br />
❸ Direct (positive-guided) opening operation ; safety function per<br />
IEC/EN 60947-5-1.<br />
Description Catalog number Price<br />
$ each<br />
Extra keys.<br />
Straight key A 20746 6.00<br />
Angled key A 20747 6.00<br />
Angled “T” key P 32753 6.00<br />
Straight “T” key P 32752 6.00<br />
Toggle key A 20748 10.00<br />
General characteristics<br />
The TS-TL series limit switches are designed and<br />
manufactured per European standards<br />
EN 50041 for dimensions.<br />
The insulated housing of the limit switch is made of<br />
self-extinguishing thermoplastic giving excellent<br />
mechanical stability and is suitable, as a result, for<br />
assembly on machinery or installations in the<br />
general-purpose industrial field.<br />
The housing sturdiness makes these switches ideal for<br />
use in heavy duty applications.<br />
The double-insulated housing of the limit switch protects<br />
internal circuits against shocks or impacts in industrial<br />
environments, against accidental ingress of tools, and<br />
accidental contact.<br />
The contacts are designed to ensure self cleaning of the<br />
silver-alloy contact surfaces. Contacts (NC) of the TL<br />
series have direct (positive-guided) opening operation to<br />
prevent sticking or welding.<br />
Operational characteristics<br />
– Maximum operating rate: 1200 cy/h<br />
– Switching time: 0.5-1.5m/s<br />
– Mechanical life: >10 million cycles<br />
– Utilization category (UL designation):<br />
• DC13 duty: 1.5A 24V (R150)<br />
• AC15 duty: 6A 250V (B600)<br />
– Rated thermal current Ith: 6A<br />
– Rated insulation voltage Ui: 250VAC<br />
– Contact resistance:
electric<br />
Rope lever for<br />
normal stopping<br />
RS1 13 10<br />
RS2 13 10<br />
RS3 13 10<br />
Limit, micro and foot switches<br />
Rope-pull lever limit switches<br />
Normal stopping<br />
Contacts Ring Catalog number Price<br />
material<br />
$ each<br />
Without reset button.<br />
1NO+1NC Steel RS1 13 10 48.00<br />
Snap action<br />
1NO+1NC Steel RS2 13 10 46.00<br />
Slow break<br />
2NO Steel RS3 13 10 48.00<br />
Slow break<br />
Type<br />
RS1 13 10<br />
RS2 13 10<br />
RS3 13 10<br />
TS1 13 10<br />
TL1 13 10<br />
Forward travel of snap action contacts<br />
Return travel of snap action contacts<br />
8-21<br />
open<br />
closed<br />
21-22<br />
13-14<br />
21-22<br />
13-14<br />
0 [mm] 6 (0.24in)<br />
21-22<br />
13-14<br />
0 [mm] 6 (0.24in)<br />
21-22<br />
11-12<br />
0 [mm] 6 (0.24in)<br />
21-22<br />
13-14<br />
21-22<br />
13-14<br />
0 [mm] 6 (0.24in)<br />
21-22<br />
13-14<br />
0 [mm] 6 (0.24in)<br />
Rope lever for<br />
normal stopping<br />
Contacts Ring Catalog number Price<br />
material<br />
$ each<br />
Without reset button.<br />
1NO+1NC Steel TS1 13 10 65.00<br />
Snap action<br />
1NO+1NC Steel TL1 13 10 63.00<br />
Slow break<br />
General characteristics<br />
The RS and T series limit switches are designed and<br />
manufactured according to European standards for<br />
dimensions EN 50041 and EN 50047, and operating<br />
characteristics.<br />
The double-insulated housing of the limit switch is made<br />
of glass-reinforced self-extinguishing polyamide resin to<br />
protect internal circuits against shocks or impacts in<br />
industrial environments, against accidental ingress of<br />
tools and accidental contact.<br />
The contacts are designed to ensure self cleaning of the<br />
silver-alloy contact surfaces.<br />
8<br />
TS1 1310 - TL1 13 10<br />
PG adapters for all<br />
RS and T types<br />
Description Catalog number Price<br />
$ each<br />
Metal, for PG11 to 1 /2 NPT G611 2.50<br />
Plastic, for PG11 to 1 /2 NPT G612 1.50<br />
Metal, for PG13.5 to 1 /2 NPT G613 2.50<br />
Plastic, for PG13.5 to 1 /2 NPT G614 1.50<br />
Operational characteristics<br />
– Maximum operating rate: 3600 cycles/h for<br />
RS...13 10; 1200 cycles/h for T...13 10<br />
– Switching time: 0.5-1.5m/s<br />
– Mechanical life: >10 million cycles<br />
– Utilization category (UL designation):<br />
• DC13 duty: 1.5A 24V (R150)<br />
• AC15 duty: 6A 250V (B600)<br />
– Conventional thermal current Ith: 10A<br />
– Rated insulation voltage Ui: 250VAC<br />
– Contact resistance:
8<br />
8-22<br />
Rope lever for<br />
emergency stopping<br />
RS13 13 10<br />
TL13 13 10<br />
Limit, micro and foot switches<br />
Rope-pull lever safety switches. EN418 compliant<br />
Accessories and spare parts<br />
Contacts Force Catalog Price<br />
number<br />
[N]<br />
$ each<br />
With reset button.<br />
1NO + 1NC❶ 25 (5.6lb) RS13 13 10 54.00<br />
1NO + 1NC❶ 25 (5.6lb) TL13 13 10 69.00<br />
❶ Direct (positive-guided) opening operation<br />
IEC/EN 60947-5-1.<br />
Example of wiring diagram<br />
R<br />
S<br />
T<br />
MOTORE<br />
M<br />
3<br />
N<br />
MARCIA START<br />
STOP ARRESTO<br />
; safety function per<br />
ROPE FUNE<br />
INTERRUTTORE<br />
ROPE LEVER<br />
DI SWITCH SICUREZZA A FUNE<br />
ELEMENTO CONTACT<br />
DI ELEMENT CONTATTO<br />
Type<br />
RS...<br />
T...<br />
General characteristics<br />
The rope-operated safety switches for emergency stop<br />
are mainly suitable for emergency stop or alarm systems<br />
for machinery which occupies a large space. This<br />
emergency stop can be achieved from any point when<br />
the rope is manually pulled each time.<br />
The choice of the body, between plastic and metal, can<br />
satisfy the most diversified requirements for sturdiness<br />
and size.<br />
Operational characteristics<br />
– Maximum operating rate: 1800 cy/h<br />
– Mechanical life: 100,000 cycles<br />
– Utilization category (UL designation):<br />
• DC13 duty: 1.5A 24V (R150)<br />
• AC15 duty: 6A 250V (B600)<br />
– Conventional thermal current Ith: 10A<br />
– Rated insulation voltage Ui: 250VAC<br />
– Contact resistance:
electric<br />
Limit, micro and foot switches<br />
Micro switches<br />
8-23<br />
Micro switches<br />
KS A1...<br />
KS A2...<br />
KS A3...<br />
KS A4...<br />
KS A9...<br />
KS B1...<br />
KS B2...<br />
KS C1...<br />
KS C2...<br />
KS C3...<br />
KS C9...<br />
KS L1...<br />
KS L2...<br />
KS L3...<br />
Description Type of Catalog Price<br />
terminal number<br />
$ each<br />
Top push rod - metal plunger.<br />
Pin Solder KS A1 S 9.50<br />
Pin Screw KS A1 V 9.80<br />
Pin Faston KS A1 F 10.50<br />
High rod plunger Solder KS A2 S 11.80<br />
High rod plunger Screw KS A2 V 12.00<br />
High rod plunger Faston KS A2 F 12.70<br />
Low rod plunger Solder KS A3 S 11.00<br />
Low rod plunger Screw KS A3 V 11.30<br />
Low rod plunger faston KS A3 F 12.00<br />
M12 fixing head.<br />
Rod plunger Solder KS A4 S 14.30<br />
Rod plunger Screw KS A4 V 14.70<br />
Rod plunger Faston KS A4 F 15.40<br />
Push button.<br />
Hand operation Solder KS A9 S 10.20<br />
Hand operation Screw KS A9 V 10.40<br />
Hand operation Faston KS A9 F 11.10<br />
M12 fixing head.<br />
Top roller push plunger Solder KS B1 S 17.50<br />
Top roller push plunger Screw KS B1 V 17.90<br />
Top roller push plunger Faston KS B1 F 18.60<br />
Top roller push plunger 90°❶ Solder KS B2 S 17.90<br />
Top roller push plunger 90°❶ Screw KS B2 V 17.50<br />
Top roller push plunger 90°❶ Faston KS B2 F 18.60<br />
Roller center push lever.<br />
26.6mm (1.05in) lever Solder KS C1 S 11.50<br />
26.6mm (1.05in) lever Screw KS C1 V 11.80<br />
26.6mm (1.05in) lever Faston KS C1 F 12.50<br />
48.5mm (1.91in) lever Solder KS C2 S 11.80<br />
48.5mm (1.91in) lever Screw KS C2 V 12.20<br />
48.5mm (1.91in) lever Faston KS C2 F 12.90<br />
38mm (1.5in) lever Solder KS C3 S 11.80<br />
38mm (1.5in) lever Screw KS C3 V 12.20<br />
38mm (1.5in) lever Faston KS C3 F 12.90<br />
One-way roller lever Solder KS C9 S 13.90<br />
One-way roller lever Screw KS C9 V 14.30<br />
One-way roller lever Faston KS C9 F 14.90<br />
Operating lever.<br />
Flat 63mm (2.48in) long, Solder KS L1 S 10.50<br />
reverse acting<br />
Flat 63mm (2.48in) long, Screw KS L1 V 10.80<br />
reverse acting<br />
Flat 63mm (2.48in) long, Faston KS L1 F 11.50<br />
reverse acting<br />
Flat 54mm (2.13in) long, Solder KS L2 S 10.50<br />
reverse acting<br />
Flat 54mm (2.13in) long, Screw KS L2 V 10.80<br />
reverse acting<br />
Flat 54mm (2.13in) long, Faston KS L2 F 11.50<br />
reverse acting<br />
Round 168.3mm (6.63in) long Solder KS L3 S 14.30<br />
Round 168.3mm (6.63in) long Screw KS L3 V 14.70<br />
Round 168.3mm (6.63in) long Faston KS L3 F 15.40<br />
Accessories.<br />
Terminal protection cover KSS C01 0.80<br />
Terminal protection cover with grommet KSS CB2 1.90<br />
General characteristics<br />
Micro switches are very compact and simple<br />
electromechanical limit switches, universally used for<br />
many years in many applications to detect the position<br />
of mobile parts not closely related with the safety of<br />
machinery.<br />
Typically micro switches are composed by a plastic body<br />
which contains contacts in 1NO, NC, common SPDT<br />
switch configuration; the terminals for electric<br />
connection are directly accessible and are not protected,<br />
except with appropriate accessories.<br />
Owing to their structure, the direct opening operation of<br />
NC contacts cannot be ensured; therefore these micro<br />
switches are not suitable for safety applications, such as<br />
machinery protection control.<br />
Since electric contact terminals, as mentioned above, are<br />
easily accessible and not protected, micro switches must<br />
be positioned in a suitable ambient, sheltered from<br />
external agents or equipped with appropriate terminal<br />
covers.<br />
Operational characteristics<br />
– Maximum operating rate: 240 cycles/min<br />
– Switching time: 0.01 - 1m/s<br />
– Mechanical life: 20 million cycles<br />
– Contacts: 1NO, 1NC and common SPDT switch<br />
– Conventional thermal current Ith: 15A<br />
– UL designation: A600 P300<br />
– Contact resistance:
8-24<br />
Limit, micro and foot switches<br />
Foot switches<br />
electric<br />
8<br />
Foot switches<br />
KG2 00 S11<br />
KG2 20 L11<br />
KG1 10 L11<br />
M20 ENTRY<br />
For types with PG13.5 entry,<br />
add the letter P at the end of<br />
the catalog number.<br />
E.g. KG1 00 S11P<br />
KR2 00 L11<br />
KR2 20 S11<br />
KR2 10 L11<br />
KR2 11 S22<br />
Model Contacts Catalog number<br />
Plastic<br />
Metal<br />
body Price body Price<br />
$ each $ each<br />
ONE PEDAL FOOT SWITCHES.<br />
With free actuation.<br />
Open 1NO+1NC KG1 00 S11 65.00 KR1 00 S11 120.00<br />
Snap action ❶<br />
Open 1NO+1NC KG1 00 L11 62.00 KR1 00 L11 117.00<br />
Slow break ❶<br />
With 1NO+1NC KG2 00 S11 78.00 KR2 00 S11 144.00<br />
cover Snap action ❶<br />
With 1NO+1NC KG2 00 L11 75.00 KR2 00 L11 141.00<br />
cover Slow break ❶<br />
With safety lever.<br />
Open 1NO+1NC KG1 10 S11 67.00 KR1 10 S11 122.00<br />
Snap action ❶<br />
Open 1NO+1NC KG1 10 L11 64.00 KR1 10 L11 119.00<br />
Slow break ❶<br />
With 1NO+1NC KG2 10 S11 80.00 KR2 10 S11 146.00<br />
cover Snap action ❶<br />
With 1NO+1NC KG2 10 L11 77.00 KR2 10 L11 143.00<br />
cover Slow break ❶<br />
With 2NO+2NC KG2 10 S22 96.00 KR2 10 S22 178.00<br />
cover Snap action ❶<br />
With pedal actuator lock.<br />
Open 1NO+1NC KG1 20 S11 72.00 KR1 20 S11 131.00<br />
Snap action ❶<br />
Open 1NO+1NC KG1 20 L11 69.00 KR1 20 L11 128.00<br />
Slow break ❶<br />
With 1NO+1NC KG2 20 S11 84.00 KR2 20 S11 153.00<br />
cover Snap action ❶<br />
With 1NO+1NC KG2 20 L11 81.00 KR2 20 L11 150.00<br />
cover Slow break ❶<br />
With two-stage safety lever.<br />
With 2NO+2NC KG2 11 S22 112.00 KR2 11 S22 207.00<br />
cover 2-stage<br />
snap action ❶<br />
❶ Direct (positive-guided) opening ; safety function per IEC/EN 60947-5-1.<br />
General characteristics<br />
The KG and KR series foot switches are used to control<br />
machinery and other equipment, leaving the operator’s<br />
hands free to do other functions. The sturdiness of the metal<br />
and plastic body and the wide range of the available versions<br />
provide the proper solution for each control need.<br />
Main features are:<br />
– Thermoplastic or metal version.<br />
The plastic or metal body gives adequate robustness to<br />
the foot switch, for installation in all ambient and<br />
application conditions.<br />
– Versions complete with or without pedal protection cover.<br />
The cover assures protection against accidental foot<br />
switch operation, due to sudden tool or heavy material<br />
dropping or other shock or vibration. The type without<br />
cover, open version, is instead immediately accessible<br />
and is preferred when the most important pedal operation<br />
is to stop a machine.<br />
– Versions with safety lever.<br />
The safety mechanism prevents unintentional foot switch<br />
activation and excludes the pedal to be pressed if the<br />
operator’s foot is not completely in place.<br />
– Stable pedal base.<br />
The foot switch is equipped with rubber feet and metalreinforced<br />
base for a firm and non-sliding position and a<br />
more reliable and safe activation.<br />
Operational characteristics<br />
– Mechanical life: >10 million cycles<br />
– Conventional thermal current Ith: 10A<br />
– UL designation:<br />
• A600 Q600 for KG series<br />
• A300 Q300 for KR series<br />
– Tightening torque for contacts: 0.74lbft / 1Nm<br />
– Rated insulation voltage Ui:<br />
• 690VAC for KG series<br />
• 440VAC for KR series<br />
– Rated impulse withstand voltage Uimp:<br />
• 6kV for KG series<br />
• 4kV for KR series<br />
– Class II insulation (KG series only)<br />
– Contact resistance:
electric<br />
Limit, micro and foot switches<br />
Foot switches and accessories<br />
8-25<br />
Foot switches<br />
KGD 003 - KGD 004<br />
M20 ENTRY<br />
For types with PG13.5 entry,<br />
add the letter P at the end of<br />
the catalog number.<br />
E.g. KG1 00 S11P<br />
Model Contacts Catalog number<br />
(for each Plastic Metal<br />
pedal) body Price body Price<br />
$ each $ each<br />
TWO PEDAL FOOT SWITCHES.<br />
With safety lever on both pedals.<br />
Both 1NO+1NC KGD 001 202.00 KRD 001 373.00<br />
with Snap action ❶<br />
cover<br />
Both 2NO+2NC KGD 002 240.00 KRD 002 441.00<br />
with Snap action ❶<br />
cover<br />
Left pedal with free actuation and right pedal with safety lever.<br />
Left 1NO+1NC KGD 003 187.00 KRD 003 345.00<br />
open Snap action ❶<br />
Right<br />
with<br />
cover<br />
Left 1NO+1NC KGD 004 205.00 KRD 004 380.00<br />
open Snap action ❶<br />
Right 2NO+2NC<br />
with Snap action ❶<br />
cover<br />
❶ Direct (positive-guided) opening ; safety function per IEC/EN 60947-5-1.<br />
General characteristics<br />
The KG and KR series foot switches are used to control<br />
machinery and other equipment, leaving the operator’s<br />
hands free to do other functions. The sturdiness of the metal<br />
and plastic body and the wide range of the available versions<br />
provide the proper solution for each control need.<br />
Main features are:<br />
– Thermoplastic or metal version.<br />
The plastic or metal body gives adequate robustness to<br />
the foot switch, for installation in all ambient and<br />
application conditions.<br />
– Versions complete with or without pedal protection cover.<br />
The cover assures protection against accidental foot<br />
switch operation, due to sudden tool or heavy material<br />
dropping or other shock or vibration. The type without<br />
cover, open version, is instead immediately accessible<br />
and is preferred when the most important pedal operation<br />
is to stop a machine.<br />
– Versions with safety lever.<br />
The safety mechanism prevents unintentional foot switch<br />
activation and excludes the pedal to be pressed if the<br />
operator’s foot is not completely in place.<br />
– Stable pedal base.<br />
The foot switch is equipped with rubber feet and metalreinforced<br />
base for a firm and non-sliding position and a<br />
more reliable and safe activation.<br />
Operational characteristics<br />
– Mechanical life: >10 million cycles<br />
– Conventional thermal current Ith: 10A<br />
– UL designation:<br />
• A600 Q600 for KG series<br />
• A300 Q300 for KR series<br />
– Tightening torque for contacts: 0.74lbft / 1Nm<br />
– Rated insulation voltage Ui:<br />
• 690VAC for KG series<br />
• 440VAC for KR series<br />
– Rated impulse withstand voltage Uimp:<br />
• 6kV for KG series<br />
• 4kV for KR series<br />
– Class II insulation (KG series only)<br />
– Contact resistance:
PAGE 9-2<br />
GX SERIES<br />
• 16A to 40A capacity<br />
• Square-shaped contact body<br />
• IP20 degree of protection of terminals<br />
• IP65 degree of protection on front, standard<br />
supplied.<br />
PAGE 9-10<br />
GN SERIES<br />
• 12A to 125A capacity<br />
• Round-shaped contact body<br />
• IP00 degree of protection of terminals<br />
• IP40 degree of protection on front, standard<br />
supplied.<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com
9<br />
ROTARY CAM SWITCHES<br />
Suitable for use as isolation switch<br />
for motor or non-motor loads<br />
General purpose ratings from 10 to<br />
100 Amp<br />
On/off, Double-Throw, Reversing<br />
and custom power switching<br />
applications<br />
Ammeter, voltmeter and custom<br />
control switching<br />
Finger protection, enclosures and<br />
other accessories available<br />
IP65 Type 4/4X protection available<br />
PLANET -SWITCH<br />
SEC. PAGE<br />
Front mounting versions<br />
GX GN<br />
On/Off switches. U version, front mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . 9- 2 8<br />
Double-throw switches with or without O (OFF). U version, front mounting . 9- 3 9<br />
Motor switches. U version, front mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . 9- 4 10<br />
Voltmeter switches. Ammeter switches. U version, front mounting . . . . . . . . 9- 4 11<br />
On/Off switches. U11 version, front mounting with handle operation for<br />
22mm center fixing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9- 5 12<br />
On/Off switches. U12 version, front mounting with key operation for<br />
22mm center fixing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9- 5 12<br />
On/Off switches. U25-U65 version, front mounting with padlock<br />
system, red/yellow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9- 5 12<br />
Mounting plate versions<br />
On/Off switches. O88-O98-O99 version, door-coupling and padlock system,<br />
red/yellow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9- 6 13<br />
On/Off switches. O68-O78-O79 version, door-coupling system . . . . . . . . . . . 9- 6 13<br />
Versions in enclosure<br />
On/Off switches. Double-throw switches. P version . . . . . . . . . . . . . . . . . . . . 9- 7 14<br />
Motor switches. P version with rotating handle . . . . . . . . . . . . . . . . . . . . . . . . 9- 7 15<br />
On/Off switches. P25 version with padlockable handle . . . . . . . . . . . . . . . . . . 9- 7 15<br />
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9- 16 17<br />
PAGE<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com
9-2<br />
Rotary cam switches<br />
GX series<br />
electric<br />
9<br />
U version<br />
front mounting.<br />
ON/OFF switches<br />
General Rated Front Catalog number Price<br />
purpose current plate<br />
AC21A size<br />
[A] [A] [mm] $ each<br />
ON/OFF SWITCHES.<br />
One-pole – 1 wafer – scheme 90.<br />
12 16 ■ 48 GX16 90 U 30.00<br />
1<br />
15 20 ■ 48 GX20 90 U 34.00<br />
32 32 ■ 65 GX32 90 U 45.00<br />
40 40 ■ 65 GX40 90 U 51.00<br />
Two-pole – 1 wafer – scheme 91.<br />
12 16 ■ 48 GX16 91 U 35.00<br />
1<br />
15 20 ■ 48 GX20 91 U 39.00<br />
32 32 ■ 65 GX32 91 U 51.00<br />
40 40 ■ 65 GX40 91 U 58.00<br />
Three-pole – 2 wafers – scheme 10.<br />
12 16 ■ 48 GX16 10 U 41.00<br />
1<br />
15 20 ■ 48 GX20 10 U 46.00<br />
32 32 ■ 65 GX32 10 U 61.00<br />
40 40 ■ 65 GX40 10 U 69.00<br />
Four-pole – 2 wafers – scheme 92.<br />
12 16 ■ 48 GX16 92 U 47.00<br />
1<br />
15 20 ■ 48 GX20 92 U 52.00<br />
32 32 ■ 65 GX32 92 U 71.00<br />
40 40 ■ 65 GX40 92 U 78.00<br />
Front plate sizes<br />
48x48mm = 1.9x1.9in<br />
65x65mm = 2.6x2.6in<br />
90x90mm = 3.5x3.5in<br />
0<br />
0<br />
0<br />
0<br />
General characteristics<br />
- 16 to 40A capacity<br />
- Extended mechanical and electrical life<br />
- Switching angles: 30°, 45°, 60° and 90°<br />
- Silver-alloy dual-breaking contacts. Direct<br />
(positive-guided) opening operation ; safety<br />
function per IEC/EN 60947-5-1<br />
- IP65 front degree of protection; IP20 protection of<br />
contacts<br />
- Legend marking is standard supplied as illustrated in<br />
the catalog number table; any other on request.<br />
Selection guide<br />
See pages TC-34 and 35.<br />
Optional<br />
Enlarged front plate for GX16-GX20 (65x65mm instead<br />
of standard 48x48):<br />
Add “H” after the switch rating in the order code<br />
E.g. GX16H 10 U.<br />
Enlarged front plate for GX32-GX40 (90x90mm instead<br />
of standard 65x65):<br />
Add “H” after the switch rating in the catalog number<br />
E.g. GX32H 10 U.<br />
Special versions<br />
In addition to standard types, particular versions are<br />
available with special operating circuit schemes.<br />
Contact Sales & Technical Support or complete the form;<br />
refer to the page just after TC-48.<br />
UL horsepower ratings<br />
Max AC23A<br />
Type 1 phase 3 phase power<br />
at 440V<br />
120V 240V 120V 240V 480V 600V [kW]<br />
GX16 3 /4 1 1 1 /2 3 5 5 6.5<br />
GX20 3 /4 1 1 /2 1 1 /2 3 5 5 7.5<br />
GX32 1 1 /2 3 3 7 1 /2 15 15 15<br />
GX40 2 5 5 10 15 15 18.5<br />
Example of U version switch mounting<br />
Certifications and compliance<br />
UL listed for USA and Canada, File E155982.<br />
Compliant to standards: IEC/EN 60947-1,<br />
IEC/EN 60947-3, IEC/EN 60204-1, IEC/EN 61058-1.<br />
Accessories<br />
page 9-16<br />
Dimensions<br />
page D-27<br />
Wiring diagrams<br />
page W-7<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com<br />
Technical characteristics<br />
pages TC-34 and 35
electric<br />
Rotary cam switches<br />
GX series<br />
9-3<br />
U version<br />
front mounting.<br />
Double-throw<br />
switches with 0<br />
position.<br />
Double-throw<br />
switches without 0<br />
position<br />
General Rated Front Catalog number Price<br />
purpose current plate<br />
AC21A size<br />
[A] [A] [mm] $ each<br />
DOUBLE-THROW SWITCHES WITH 0.<br />
One-pole – 1 wafer – scheme 51.<br />
12 16 ■ 48 GX16 51 U 40.00<br />
15 20 ■ 48 GX20 51 U 44.00<br />
32 32 ■ 65 GX32 51 U 59.00<br />
40 40 ■ 65 GX40 51 U 70.00<br />
Two-pole – 2 wafers – scheme 52.<br />
12 16 ■ 48 GX16 52 U 48.00<br />
15 20 ■ 48 GX20 52 U 51.00<br />
32 32 ■ 65 GX32 52 U 68.00<br />
40 40 ■ 65 GX40 52 U 81.00<br />
Three-pole – 3 wafers – scheme 53.<br />
12 16 ■ 48 GX16 53 U 60.00<br />
15 20 ■ 48 GX20 53 U 65.00<br />
32 32 ■ 65 GX32 53 U 87.00<br />
40 40 ■ 65 GX40 53 U 104.00<br />
Four-pole – 4 wafers – scheme 75.<br />
12 16 ■ 48 GX16 75 U 74.00<br />
15 20 ■ 48 GX20 75 U 79.00<br />
32 32 ■ 65 GX32 75 U 111.00<br />
40 40 ■ 65 GX40 75 U 116.00<br />
DOUBLE-THROW SWITCHES WITHOUT 0.<br />
One-pole – 1 wafer – scheme 54.<br />
12 16 ■ 48 GX16 54 U 39.00<br />
15 20 ■ 48 1 GX20 54 U 42.00<br />
32 32 ■ 65 GX32 54 U 57.00<br />
Two-pole – 2 wafers – scheme 55.<br />
12 16 ■ 48 2 GX16 55 U 44.00<br />
15 20 ■ 48 1 GX20 55 U 49.00<br />
32 32 ■ 65 GX32 55 U 66.00<br />
Three-pole – 3 wafers – scheme 56.<br />
12 16 ■ 48 2 GX16 56 U 59.00<br />
15 20 ■ 48 1 GX20 56 U 65.00<br />
32 32 ■ 65 GX32 56 U 87.00<br />
Four-pole – 4 wafers – scheme 69.<br />
12 16 ■ 48 2 GX16 69 U 71.00<br />
15 20 ■ 48 1 GX20 69 U 77.00<br />
32 32 ■ 65 GX32 69 U 116.00<br />
Front plate sizes<br />
48x48mm = 1.9x1.9in<br />
65x65mm = 2.6x2.6in<br />
90x90mm = 3.5x3.5in<br />
1<br />
0 2<br />
0 2<br />
1<br />
0 2<br />
1<br />
Certifications and compliance<br />
1<br />
2<br />
0 2<br />
General characteristics<br />
- 16 to 40A capacity<br />
- Extended mechanical and electrical life<br />
- Switching angles: 30°, 45°, 60° and 90°<br />
- Silver-alloy dual-breaking contacts. Direct<br />
(positive-guided) opening operation ; safety<br />
function per IEC/EN 60947-5-1<br />
- IP65 front degree of protection; IP20 protection of<br />
contacts<br />
- Legend marking is standard supplied as illustrated in<br />
the catalog number table; any other on request.<br />
Selection guide<br />
See pages TC-34 and 35.<br />
Optional<br />
Enlarged front plate for GX16-GX20 (65x65mm instead<br />
of standard 48x48):<br />
Add “H” after the switch rating in the catalog number<br />
E.g. GX16H 52 U.<br />
Enlarged front plate for GX32-GX40 (90x90mm instead<br />
of standard 65x65):<br />
Add “H” after the switch rating in the catalog number<br />
E.g. GX32H 52 U.<br />
Special versions<br />
In addition to standard types, particular versions are<br />
available with special operating circuit schemes.<br />
Contact Sales & Technical Support or complete the form;<br />
refer to the page just after TC-48.<br />
UL horsepower ratings<br />
Max AC23A<br />
Type 1 phase 3 phase power<br />
at 440V<br />
120V 240V 120V 240V 480V 600V [kW]<br />
GX16 3 /4 1 1 1 /2 3 5 5 6.5<br />
GX20 3 /4 1 1 /2 1 1 /2 3 5 5 7.5<br />
GX32 1 1 /2 3 3 7 1 /2 15 15 15<br />
GX40 2 5 5 10 15 15 18.5<br />
Example of U version switch mounting<br />
9<br />
UL listed for USA and Canada, File E155982.<br />
Compliant to standards: IEC/EN 60947-1,<br />
IEC/EN 60947-3, IEC/EN 60204-1, IEC/EN 61058-1.<br />
Accessories<br />
page 9-16<br />
Dimensions<br />
page D-27<br />
Wiring diagrams<br />
page W-7<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com<br />
Technical characteristics<br />
pages TC-34 and 35
9-4<br />
Rotary cam switches<br />
GX series<br />
electric<br />
9<br />
U version<br />
front mounting.<br />
Motor switches<br />
U version<br />
front mounting.<br />
Voltmeter switches.<br />
Ammeter switches<br />
General Rated Front Catalog number Price<br />
purpose current plate<br />
AC21A size<br />
[A] [A] [mm] $ each<br />
MOTOR SWITCHES❶.<br />
Reversing switches. Three-pole – 3 wafers – scheme 11.<br />
12 16 ■ 48 GX16 11 U 49.00<br />
15 20 ■ 48 GX20 11 U 58.00<br />
32 32 ■ 65 GX32 11 U 79.00<br />
40 40 ■ 65 GX40 11 U 88.00<br />
Pole-changing switches. 4 wafers – scheme 13.<br />
12 16 ■ 48 GX16 13 U 70.00<br />
15 20 ■ 48 GX20 13 U 78.00<br />
32 32 ■ 65 GX32 13 U 110.00<br />
40 40 ■ 65 GX40 13 U 116.00<br />
Wye-delta switches. 2 wafers – scheme 12.<br />
12 16 ■ 48 GX16 12 U 70.00<br />
15 20 ■ 48 GX20 12 U 78.00<br />
32 32 ■ 65 GX32 12 U 110.00<br />
40 40 ■ 65 GX40 12 U 116.00<br />
3-pole motor reversing switches with spring return to 0.<br />
3 wafers – scheme 26.<br />
12 16 ■ 48 GX16 26 U 52.00<br />
15 20 ■ 48 GX20 26 U 59.00<br />
32 32 ■ 65 GX32 26 U 80.00<br />
❶ See side table for UL horsepower ratings.<br />
General Rated Front Catalog number Price<br />
purpose current plate<br />
AC21A size<br />
[A] [A] [mm] $ each<br />
VOLTMETER SWITCHES.<br />
Phase-Neutral L1-N/L2-N/L3-N – 2 wafers – scheme 68.<br />
12 16 ■ 48 0<br />
L1N GX16 68 U 51.00<br />
L2N<br />
L3N<br />
0 2<br />
1<br />
0 2<br />
1<br />
0 2<br />
1<br />
0 2<br />
1<br />
General characteristics<br />
- 16 to 40A capacity for motor switches<br />
- 16A capacity for voltmeter and ammeter switches<br />
- Extended mechanical and electrical life<br />
- Switching angles: 30°, 45°, 60° and 90°<br />
- Silver-alloy dual-breaking contacts. Direct<br />
(positive-guided) opening operation ; safety<br />
function per IEC/EN 60947-5-1<br />
- IP65 front degree of protection; IP20 contact degree<br />
of protection<br />
- Legend marking is standard supplied as illustrated in<br />
the catalog number table; any other on request.<br />
Selection guide<br />
See pages TC-34 and 35.<br />
Optional<br />
Enlarged front plate for GX16-GX20 (65x65mm instead<br />
of standard 48x48): Add “H” after the switch rating in<br />
the catalog number E.g. GX16H 11 U.<br />
Enlarged front plate for GX32-GX40 (90x90mm instead<br />
of standard 65x65): Add “H” after the switch rating in<br />
the catalog number E.g. GX32H 11 U.<br />
Special versions<br />
In addition to standard types, particular versions are<br />
available with special operating circuit schemes.<br />
Contact Sales & Technical Support or complete the form;<br />
refer to the page just after TC-48.<br />
UL horsepower ratings<br />
Max AC23A<br />
Type 1 phase 3 phase power<br />
at 440V<br />
120V 240V 120V 240V 480V 600V [kW]<br />
GX16 3 /4 1 1 1 /2 3 5 5 6.5<br />
GX20 3 /4 1 1 /2 1 1 /2 3 5 5 7.5<br />
GX32 1 1 /2 3 3 7 1 /2 15 15 15<br />
GX40 2 5 5 10 15 15 18.5<br />
Example of U version switch mounting<br />
Phase-Phase L1-L2/L2-L3/L3-L1 – 2 wafers – scheme 67.<br />
12 16 ■ 48 0<br />
L1-L2 GX16 67 U 51.00<br />
L2-L3<br />
L3-L1<br />
For 3 phase to phase voltage and 3 phase voltage readings<br />
3 wafers – scheme 66.<br />
12 16 ■ 48 L1-L2<br />
0<br />
L1-N GX16 66 U 78.00<br />
L2-L3<br />
L3-L1<br />
L2-N<br />
L3-N<br />
For 1 phase voltage and 3 phase to phase voltage readings<br />
3 wafers – scheme 60.<br />
12 16 ■ 48 0<br />
L1N L1-L2 GX16 60 U 78.00<br />
L2-L3<br />
L3-L1<br />
Certifications and compliance<br />
UL listed for USA and Canada, File E155982.<br />
Compliant to standards: IEC/EN 60947-1,<br />
IEC/EN 60947-3, IEC/EN 60204-1, IEC/EN 61058-1.<br />
AMMETER SWITCHES.<br />
Direct L1-L2-L3 current readings – 5 wafers – scheme 97.<br />
12 16 ■ 48 0 GX16 97 U 80.00<br />
L3<br />
L1<br />
L2<br />
For L1-L2-L3 readings via 3 CTs – 3 wafers – scheme 98.<br />
12 16 ■ 48 0 GX16 98 U 62.00<br />
L3<br />
L1<br />
L2<br />
Front plate sizes<br />
48x48mm = 1.9x1.9in<br />
65x65mm = 2.6x2.6in<br />
90x90mm = 3.5x3.5in<br />
Accessories<br />
page 9-16<br />
Dimensions<br />
page D-27<br />
Wiring diagrams<br />
pages W-7 and 8<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com<br />
Technical characteristics<br />
pages TC-34 and 35
electric<br />
Rotary cam switches<br />
GX series<br />
9-5<br />
U11 version<br />
front mounting with<br />
handle operation,<br />
for central 22mm<br />
fixing.<br />
ON/OFF switches<br />
General Rated Front Catalog number Price<br />
purpose current plate<br />
AC21A size<br />
[A] [A] [mm] $ each<br />
ON/OFF SWITCHES. One-pole – 1 wafer – scheme 90.<br />
12 16 none 0 GX16 90 U11 60.00<br />
Two-pole – 1 wafer – scheme 91.<br />
12 16 none 0 GX16 91 U11 70.00<br />
1<br />
1<br />
General characteristics<br />
- 16 to 40A capacity<br />
- Extended mechanical and electrical life<br />
- Switching angles: 30°, 45°, 60° and 90°<br />
- Silver-alloy dual-breaking contacts. Direct<br />
(positive-guided) opening operation ; safety<br />
function per IEC/EN 60947-5-1<br />
- IP65 front degree of protection; IP20 protection of<br />
contacts<br />
- Legend marking for U11 and U12 versions is for<br />
reference only while for U25 and U65 types standard<br />
supplied as illustrated in the catalog number table;<br />
any other on request.<br />
U12 version<br />
front mounting<br />
with key operation,<br />
for central 22mm<br />
fixing.<br />
ON/OFF switches<br />
Three-pole – 2 wafers – scheme 10.<br />
12 16 none 0 GX16 10 U11 80.00<br />
Four-pole – 2 wafers – scheme 92.<br />
12 16 none 0 GX16 92 U11 90.00<br />
General Rated Front Catalog number Price<br />
purpose current plate<br />
AC21A size<br />
[A] [A] [mm] $ each<br />
ON/OFF SWITCHES. One-pole – 1 wafer – scheme 90.<br />
12 16 none 0 GX16 90 U12 64.00<br />
Two-pole – 1 wafer – scheme 91.<br />
12 16 none 0 GX16 91 U12 74.00<br />
Three-pole – 2 wafers – scheme 10.<br />
12 16 none 0 GX16 10 U12 84.00<br />
1<br />
1<br />
1<br />
1<br />
1<br />
Selection guide<br />
See pages TC-34 and 35.<br />
Optional<br />
Enlarged front plate for GX16-GX20 (65x65mm instead<br />
of standard 48x48):<br />
Add “H” after the switch rating in the catalog number<br />
E.g. GX16H 10 U25.<br />
Enlarged front plate for GX32-GX40 (90x90mm instead<br />
of standard 65x65):<br />
Add “H” after the switch rating in the catalog number<br />
E.g. GX32H 10 U25.<br />
Special versions<br />
In addition to standard types, particular versions are<br />
available with special operating circuit schemes.<br />
Contact Sales & Technical Support or complete the form;<br />
refer to the page just after TC-48.<br />
UL horsepower ratings<br />
Max AC23A<br />
Type 1 phase 3 phase power<br />
at 440V<br />
120V 240V 120V 240V 480V 600V [kW]<br />
GX16 3 /4 1 1 1 /2 3 5 5 6.5<br />
GX20 3 /4 1 1 /2 1 1 /2 3 5 5 7.5<br />
GX32 1 1 /2 3 3 7 1 /2 15 15 15<br />
GX40 2 5 5 10 15 15 18.5<br />
Example of U25-U65 switch mounting<br />
9<br />
Four-pole – 2 wafers – scheme 92.<br />
12 16 none 0 GX16 92 U12 94.00<br />
1<br />
U25-U65 versions<br />
front mounting with<br />
red/yellow padlock<br />
system.<br />
ON/OFF switches<br />
General Rated Front Catalog number Price<br />
purpose current plate<br />
AC21A size<br />
[A] [A] [mm] $ each<br />
ON/OFF SWITCHES. Three-pole – 2 wafers – scheme 10.<br />
12 16 ■ 48 GX16 10 U25 43.00<br />
1<br />
15 20 ■ 48 GX20 10 U25 51.00<br />
32 32 ■ 65 GX32 10 U25 63.00<br />
40 40 ■ 65 GX40 10 U65 74.00<br />
Four-pole – 2 wafers – scheme 92.<br />
12 16 ■ 48 GX16 92 U25 49.00<br />
1<br />
15 20 ■ 48 GX20 92 U25 56.00<br />
32 32 ■ 65 GX32 92 U25 73.00<br />
40 40 ■ 65 GX40 92 U65 80.00<br />
Front plate sizes<br />
48x48mm = 1.9x1.9in<br />
65x65mm = 2.6x2.6in<br />
90x90mm = 3.5x3.5in<br />
0<br />
0<br />
Certifications and compliance<br />
UL listed for USA and Canada, File E155982.<br />
Compliant to standards: IEC/EN 60947-1,<br />
IEC/EN 60947-3, IEC/EN 60204-1, IEC/EN 61058-1.<br />
Accessories<br />
page 9-16<br />
Dimensions<br />
page D-27<br />
Wiring diagrams<br />
page W-7<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com<br />
Technical characteristics<br />
pages TC-34 and 35
9-6<br />
Rotary cam switches<br />
GX series<br />
electric<br />
O88 - O98 versions<br />
door coupling with<br />
red/yellow padlock<br />
system.<br />
ON/OFF switches<br />
General Rated Front Catalog number Price<br />
purpose current plate<br />
AC21A size<br />
[A] [A] [mm] $ each<br />
ON/OFF SWITCHES.<br />
Three-pole – 2 wafers – scheme 10.<br />
12 16 ■ 48 GX16 10 O88 64.00<br />
1<br />
15 20 ■ 48 GX20 10 O88 72.00<br />
32 32 ■ 65 GX32 10 O88 82.00<br />
40 40 ■ 65 GX40 10 O88 104.00<br />
Four-pole – 2 wafers – scheme 92.<br />
12 16 ■ 48 GX16 92 O88 68.00<br />
1<br />
15 20 ■ 48 GX20 92 O88 75.00<br />
32 32 ■ 65 GX32 92 O88 90.00<br />
40 40 ■ 65 GX40 92 O98 116.00<br />
Front plate sizes<br />
48x48mm = 1.9x1.9in<br />
65x65mm = 2.6x2.6in<br />
90x90mm = 3.5x3.5in<br />
0<br />
0<br />
General characteristics<br />
- 16 to 40A capacity<br />
- Extended mechanical and electrical life<br />
- Switching angles: 30°, 45°, 60° and 90°<br />
- Silver-alloy dual-breaking contacts. Direct<br />
(positive-guided) opening operation ; safety<br />
function per IEC/EN 60947-5-1<br />
- IP65 front degree of protection; IP20 contact degree<br />
of protection<br />
- Suitable for screw fixing or mounting on 35mm DIN<br />
rail (IEC/EN 60715)<br />
- Self alignment feature<br />
- Legend marking is standard supplied as illustrated in<br />
the catalog number table; any other on request.<br />
Selection guide<br />
See pages TC-34 and 35.<br />
Optional<br />
Enlarged front plate for GX16-GX20 (65x65mm instead<br />
of standard 48x48):<br />
Add “H” after the switch rating in the catalog number<br />
E.g. GX16H 10 O88.<br />
9<br />
O68 - O78 versions<br />
door coupling.<br />
ON/OFF switches<br />
General Rated Front Catalog number Price<br />
purpose current plate<br />
AC21A size<br />
[A] [A] [mm] $ each<br />
ON/OFF SWITCHES.<br />
Three-pole – 2 wafers – scheme 10.<br />
12 16 ■ 48 GX16 10 O68 62.00<br />
1<br />
15 20 ■ 48 GX20 10 O68 67.00<br />
32 32 ■ 65 GX32 10 O68 80.00<br />
40 40 ■ 65 GX40 10 O78 99.00<br />
Four-pole – 2 wafers – scheme 92.<br />
12 16 ■ 48 GX16 92 O68 66.00<br />
1<br />
15 20 ■ 48 GX20 92 O68 72.00<br />
32 32 ■ 65 GX32 92 O68 85.00<br />
40 40 ■ 65 GX40 92 O78 114.00<br />
Front plate sizes<br />
48x48mm = 1.9x1.9in<br />
65x65mm = 2.6x2.6in<br />
90x90mm = 3.5x3.5in<br />
0<br />
0<br />
Enlarged front plate for GX32-GX40 (90x90mm instead<br />
of standard 65x65):<br />
Add “H” after the switch rating in the catalog number<br />
E.g. GX32H 10 O88.<br />
Special versions<br />
In addition to standard types, particular versions are<br />
available with special operating circuit schemes.<br />
Contact Sales & Technical Support or complete the form;<br />
refer to the page just after TC-48.<br />
UL horsepower ratings<br />
Max AC23A<br />
Type 1 phase 3 phase power<br />
at 440V<br />
120V 240V 120V 240V 480V 600V [kW]<br />
GX16 3 /4 1 1 1 /2 3 5 5 6.5<br />
GX20 3 /4 1 1 /2 1 1 /2 3 5 5 7.5<br />
GX32 1 1 /2 3 3 7 1 /2 15 15 15<br />
GX40 2 5 5 10 15 15 18.5<br />
Example of O version switch mounting<br />
Certifications and compliance<br />
UL listed for USA and Canada, File E155982.<br />
Compliant to standards: IEC/EN 60947-1,<br />
IEC/EN 60947-3, IEC/EN 60204-1, IEC/EN 61058-1.<br />
Accessories<br />
page 9-16<br />
Dimensions<br />
page D-27<br />
Wiring diagrams<br />
page W-7<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com<br />
Technical characteristics<br />
pages TC-34 and 35
electric<br />
Rotary cam switches<br />
GX series<br />
9-7<br />
P version in<br />
enclosure with<br />
rotating handle.<br />
On/Off switches.<br />
Double-throw<br />
switches<br />
1<br />
General Rated Type Catalog number Price<br />
purpose current size<br />
AC21A<br />
[A] [A] [mm] $ each<br />
ON/OFF SWITCHES.<br />
Three poles - scheme 10.<br />
12 16 90x90 GX16 10 P 117.00<br />
0<br />
15 20 90x90<br />
1<br />
GX20 10 P 124.00<br />
32 32 110x110 GX32 10 P 136.00<br />
40 40 110x110 GX40 10 P 144.00<br />
Four poles - scheme 92.<br />
12 16 90x90 GX16 92 P 128.00<br />
0<br />
15 20 90x90<br />
1<br />
GX20 92 P 132.00<br />
32 32 110x110 GX32 92 P 150.00<br />
40 40 110x110 GX40 92 P 161.00<br />
DOUBLE-THROW SWICTHES.<br />
Three poles - scheme 53.<br />
12 16 90x90 GX16 53 P 138.00<br />
15 20 90x90<br />
0 2<br />
GX20 53 P 142.00<br />
32 32 110x110 GX32 53 P 167.00<br />
40 40 110x110 GX40 53 P 178.00<br />
Four poles - scheme 75.<br />
12 16 90x90 GX16 75 P 146.00<br />
15 20 90x90<br />
1<br />
0 2<br />
GX20 75 P 149.00<br />
32 32 110x110 GX32 75 P 179.00<br />
40 40 110x110 GX40 75 P 193.00<br />
General characteristics<br />
– 16 to 40A capacity<br />
– Extended mechanical and electrical life<br />
– Switching angles: 30°, 45°, 60° and 90°<br />
- Silver-alloy dual-breaking contacts. Direct<br />
(positive-guided) opening operation ; safety<br />
function per IEC/EN 60947-5-1<br />
– IP65 degree of protection<br />
– Top and bottom entry: 4 PG16 threaded knockouts for<br />
90x90mm types and 4 PG21 for 110x110mm; metric<br />
entry available on request. NPT adapters are given on<br />
page 9-16<br />
– Legend marking is standard supplied as illustrated in<br />
the catalog number table; any other on request.<br />
Selection guide<br />
See pages TC-34 and 35.<br />
Special versions<br />
In addition to standard types, particular versions are<br />
available with special operating circuit schemes.<br />
Contact Sales & Technical Support or complete the form;<br />
refer to the page just after TC-48.<br />
UL horsepower ratings<br />
Max AC23A<br />
Type 1 phase 3 phase power<br />
at 440V<br />
120V 240V 120V 240V 480V 600V [kW]<br />
GX16 3 /4 1 1 1 /2 3 5 5 6.5<br />
GX20 3 /4 1 1 /2 1 1 /2 3 5 5 7.5<br />
GX32 1 1 /2 3 3 7 1 /2 15 15 15<br />
GX40 2 5 5 10 15 15 18.5<br />
P version in<br />
enclosure with<br />
rotating handle.<br />
Motor switches<br />
General Rated Type Catalog number Price<br />
purpose current size<br />
AC21A<br />
[A] [A] [mm] $ each<br />
MOTOR SWITCHES❶.<br />
Three-pole reversing switches - scheme 11.<br />
12 16 90x90 GX16 11 P 136.00<br />
15 20 90x90<br />
1<br />
0 2<br />
GX20 11 P 145.00<br />
32 32 110x110 GX32 11 P 166.00<br />
40 40 110x110 GX40 11 P 175.00<br />
Certifications and compliance<br />
UL listed for USA and Canada, File E155982.<br />
Compliant to standards: IEC/EN 60947-1,<br />
IEC/EN 60947-3, IEC/EN 60204-1, IEC/EN 61058-1.<br />
9<br />
❶ See side table for UL horsepower ratings.<br />
P version in<br />
enclosure with<br />
padlockable<br />
rotating handle.<br />
On/Off switches<br />
General Rated Type Catalog number Price<br />
purpose current size<br />
AC21A<br />
[A] [A] [mm] $ each<br />
ON/OFF SWITCHES.<br />
Three poles - scheme 10.<br />
12 16 90x90 0<br />
1<br />
GX16 10 P25 124.00<br />
15 20 90x90 GX20 10 P25 130.00<br />
32 32 110x110 GX32 10 P25 145.00<br />
Four poles - scheme 92.<br />
12 16 90x90 0<br />
1<br />
GX16 92 P25 132.00<br />
15 20 90x90 GX20 92 P25 144.00<br />
32 32 110x110 GX32 92 P25 162.00<br />
Enclosure type sizes<br />
90x90mm = 3.5x3.5in<br />
110x110mm = 4.3x4.3in<br />
Accessories<br />
page 9-16<br />
Dimensions<br />
page D-27<br />
Wiring diagrams<br />
page W-7<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com<br />
Technical characteristics<br />
pages TC-34 and 35
9-8<br />
Rotary cam switches<br />
GN series<br />
electric<br />
9<br />
U version<br />
front mounting.<br />
On/Off switches<br />
General Rated Front Catalog number Price<br />
purpose current plate<br />
AC21A size<br />
[A] [A] [mm] $ each<br />
ON/OFF SWITCHES.<br />
One pole - 1 wafer - scheme 90.<br />
10 12 ■ 48 7 GN12 90 U 30.00<br />
15 20 ■ 48 7 GN20 90 U 34.00<br />
1<br />
20 25 ■ 48 7 GN25 90 U 39.00<br />
32 32 ■ 65 7 GN32 90 U 45.00<br />
35 40 ■ 65 7 GN40 90 U 51.00<br />
55 63 ■ 65 7 GN63 90 U 68.00<br />
2 poles - 1 wafer - scheme 91.<br />
10 12 ■ 48 7 GN12 91 U 35.00<br />
15 20 ■ 48 7 GN20 91 U 39.00<br />
1<br />
20 25 ■ 48 7 GN25 91 U 45.00<br />
32 32 ■ 65 7 GN32 91 U 51.00<br />
35 40 ■ 65 7 GN40 91 U 58.00<br />
55 63 ■ 65 7 GN63 91 U 74.00<br />
3 poles - 2 wafers - scheme 10.<br />
10 12 ■ 48 7 GN12 10 U 41.00<br />
15 20 ■ 48 7 GN20 10 U 46.00<br />
20 25 ■ 48 0 7 GN25 10 U 53.00<br />
32 32 ■ 65 7 GN32 10 U 61.00<br />
35 40 ■ 65 7 GN40 10 U 69.00<br />
55 63 ■ 65 7 GN63 10 U 97.00<br />
100 125 ■ 90 7 GN125 10 U 293.00<br />
4 poles - 2 wafers - scheme 92.<br />
10 12 ■ 48 7 GN12 92 U 47.00<br />
15 20 ■ 48 7 GN20 92 U 52.00<br />
20 25 ■ 48 0 7 GN25 92 U 61.00<br />
22 32 ■ 65 7 GN32 92 U 71.00<br />
35 40 ■ 65 7 GN40 92 U 78.00<br />
55 63 ■ 65 7 GN63 92 U 109.00<br />
100 125 ■ 90 7 GN125 92 U 313.00<br />
Front plate sizes<br />
48x48mm = 1.9x1.9in<br />
65x65mm = 2.6x2.6in<br />
90x90mm = 3.5x3.5in<br />
0<br />
0<br />
1<br />
1<br />
General characteristics<br />
– 12 to 125A capacity<br />
– Extended mechanical and electrical life<br />
– Switching angles: 30°, 45°, 60° and 90°<br />
- Silver-alloy dual-breaking contacts. Direct<br />
(positive-guided) opening operation ; safety<br />
function per IEC/EN 60947-5-1<br />
– Open type<br />
– IP40 front degree of protection (for IP65 see<br />
Optional-front plate), IP00 for contacts<br />
– Legend marking is per standard supplied, as<br />
illustrated in the catalog number table; any other on<br />
request.<br />
Selection guide<br />
See pages TC-34 and 35.<br />
Optional<br />
IP65 front plate<br />
Add “51” at the end of the catalog number.<br />
E.g. 7 GN12 92 U 51.<br />
Enlarged plate for GN12-20-25 (65x65 instead of 48x48)<br />
Add the letter “H” after the switch size of the catalog<br />
number.<br />
E.g. 7 GN12H 10 U.<br />
Enlarged plate for GN32-40-63 (90x90 instead of 65x65)<br />
Add the letter “H” after the switch size of the catalog<br />
number.<br />
E.g. 7 GN32H 10 U.<br />
Special versions<br />
In addition to standard types, particular versions are<br />
available with special operating circuit diagrams.<br />
Contact Sales & Technical Support or complete the form;<br />
refer to the page just after TC-48.<br />
UL horsepower ratings<br />
Max AC23A<br />
Type 1 phase 3 phase power<br />
at 440V<br />
120V 240V 120V 240V 480V 600V [kW]<br />
GN12 3 /4 1 1 1 /2 3 –– –– 6<br />
GN20 3 /4 2 1 1 /2 3 –– –– 7.5<br />
GN25 1 1 /2 3 3 5 10 10 11<br />
GN32 2 5 5 10 15 15 15<br />
GN40 2 5 5 10 20 20 18.5<br />
GN63 5 10 7 1 /2 15 25 25 30<br />
GN125 7 1 /2 15 15 25 50 40 45<br />
Certifications and compliance<br />
UL listed for USA, File E 155982.<br />
CSA certified for Canada and USA, File LR 207767.<br />
Compliant with standards: IEC/EN 60947,<br />
IEC/EN 60947-3, IEC/EN 60204-1, IEC/EN 61058-1.<br />
Accessories<br />
page 9-17<br />
Dimensions<br />
page D-28<br />
Wiring diagrams<br />
page W-7<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com<br />
Technical characteristics<br />
pages TC-34 and 35
electric<br />
Rotary cam switches<br />
GN series<br />
9-9<br />
U version, front<br />
mounting.<br />
Double-throw<br />
switch with or<br />
without 0 (OFF)<br />
General characteristics<br />
General Rated Front Catalog number Price<br />
15 20 ■ 48 7 GN20 53 U 65.00 Add the letter “H” after the switch size of the catalog<br />
number.<br />
20 25 ■ 48 1<br />
0 2<br />
7 GN25 53 U 76.00 E.g. 7 GN32H 52 U.<br />
purpose current plate<br />
– 12 to 125A capacity<br />
AC21A size<br />
– Extended mechanical and electrical life<br />
[A] [A] [mm] $ each – Switching angles: 30°, 45°, 60° and 90°<br />
- Silver-alloy dual-breaking contacts. Direct<br />
DOUBLE-THROW SWITCH WITH 0 (OFF).<br />
(positive-guided) opening operation ; safety<br />
1 pole - 1 wafer - scheme 51.<br />
function per IEC/EN 60947-5-1<br />
10 12 ■ 48 7 GN12 51 U 38.00 – Open type<br />
15 20 ■ 48 7 GN20 51 U 44.00 – IP40 front degree of protection (for IP65 see<br />
1<br />
0<br />
20 25 ■ 48 2<br />
Optional-front plate), IP00 for contacts<br />
7 GN25 51 U 50.00 – Legend marking is per standard supplied, as<br />
20 25 ■ 48 1<br />
0 2<br />
7 GN25 52 U 59.00 Add “51” at the end of the catalog number.<br />
32 32 ■ 65 7 GN32 51 U 59.00<br />
illustrated in the catalog number table; any other on<br />
35 40 ■ 65 7 GN40 51 U 70.00<br />
request.<br />
55 63 ■ 65 7 GN63 51 U 98.00 Selection guide<br />
2 poles - 2 wafers - circuit diagram 52.<br />
See pages TC-34 and 35.<br />
10 12 ■ 48 7 GN12 52 U 46.00<br />
Optional<br />
15 20 ■ 48 7 GN20 52 U 51.00 IP65 front plate<br />
32 32 ■ 65 7 GN32 52 U 68.00 E.g. 7 GN12 52 U 51.<br />
35 40 ■ 65 7 GN40 52 U 81.00 Enlarged plate for GN12-20-25 (65x65 instead of 48x48)<br />
55 63 ■ 65 7 GN63 52 U 112.00 Add the letter “H” after the switch size of the catalog<br />
100 125 ■ 90 7 GN125 52 U 323.00 number.<br />
E.g. 7 GN12H 52 U.<br />
3 poles - 3 wafers - circuit diagram 53.<br />
10 12 ■ 48 7 GN12 53 U 58.00 Enlarged plate for GN32-40-63 (90x90 instead of 65x65)<br />
32 32 ■ 65 7 GN32 53 U 87.00<br />
35 40 ■ 65 7 GN40 53 U 104.00 Special versions<br />
In addition to standard types, particular versions are<br />
55 63 ■ 65 7 GN63 53 U 154.00 available with special operating circuit schemes.<br />
100 125 ■ 90 7 GN125 53 U 346.00 Contact Sales & Technical Support or complete the form;<br />
4 poles - 4 wafers - circuit diagram 75.<br />
refer to the page just after TC-48.<br />
10 12 ■ 48 7 GN12 75 U 72.00<br />
UL horsepower ratings<br />
Max AC23A<br />
15 20 ■ 48 7 GN20 75 U 79.00<br />
Type 1 phase 3 phase power<br />
20 25 ■ 48 1<br />
0 2<br />
7 GN25 75 U 95.00<br />
at 440V<br />
120V 240V 120V 240V 480V 600V [kW]<br />
32 32 ■ 65 7 GN32 75 U 111.00<br />
GN12 3 /4 1 1 1 /2 3 –– –– 6<br />
35 40 ■ 65 7 GN40 75 U 116.00<br />
GN20 3 /4 2 1 1 /2 3 –– –– 7.5<br />
55 63 ■ 65 7 GN63 75 U 190.00<br />
GN25 1 1 /2 3 3 5 10 10 11<br />
100 125 ■ 90 7 GN125 75 U 391.00<br />
GN32 2 5 5 10 15 15 15<br />
DOUBLE-THROW switch without 0 (OFF).<br />
1 pole - 1 wafers - scheme 54.<br />
GN40 2 5 5 10 20 20 18.5<br />
10 12 ■ 48 2 7 GN12 54 U 37.00<br />
GN63 5 10 7 1 /2 15 25 25 30<br />
15 20 ■ 48 1 7 GN20 54 U 42.00<br />
GN125 7 1 /2 15 15 25 50 40 45<br />
20 25 ■ 48 7 GN25 54 U 57.00<br />
2 poles - 2 wafers - circuit diagram 55.<br />
10 12 ■ 48 2 7 GN12 55 U 42.00<br />
15 20 ■ 48 1 7 GN20 55 U 49.00<br />
20 25 ■ 48 7 GN25 55 U 59.00<br />
3 poles - 3 wafers - circuit diagram 56.<br />
10 12 ■ 48 2 7 GN12 56 U 57.00<br />
15 20 ■ 48 1 7 GN20 56 U 65.00<br />
20 25 ■ 48 7 GN25 56 U 76.00<br />
4 poles - 4 wafers - circuit diagram 69.<br />
10 12 ■ 48 2 7 GN12 69 U 69.00<br />
15 20 ■ 48 1 7 GN20 69 U 77.00<br />
20 25 ■ 48 7 GN25 69 U 91.00<br />
Front plate sizes<br />
48x48mm = 1.9x1.9in<br />
65x65mm = 2.6x2.6in<br />
90x90mm = 3.5x3.5in<br />
Certifications and compliance<br />
UL listed for USA, File E 155982.<br />
CSA certified for Canada and USA, File LR 207767.<br />
Compliant with standards: IEC/EN 60947-1,<br />
IEC/EN 60947-3, IEC/EN 60204-1, IEC/EN 61058-1.<br />
9<br />
Accessories<br />
page 9-17<br />
Dimensions<br />
page D-28<br />
Wiring diagrams<br />
page W-7<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com<br />
Technical characteristics<br />
pages TC-34 and 35
9-10<br />
Rotary cam switches<br />
GN series<br />
electric<br />
9<br />
U version<br />
front mounting.<br />
Motor switches<br />
General characteristics<br />
General Rated Front Catalog number Price<br />
20 25 ■ 48 0 7 GN25 12 U 95.00<br />
purpose current plate<br />
– 12 to 125A capacity<br />
AC21A size<br />
– Extended mechanical and electrical life<br />
[A] [A] [mm] $ each – Switching angles: 30°, 45°, 60° and 90°<br />
- Silver-alloy dual-breaking contacts. Direct<br />
MOTOR SWITCHES❶.<br />
(positive-guided) opening operation ; safety<br />
3-pole reversing switches - 3 wafers - scheme 11.<br />
function per IEC/EN 60947-5-1<br />
10 12 ■ 48 7 GN12 11 U 49.00 – Open type<br />
15 20 ■ 48 7 GN20 11 U 58.00 – IP40 front degree of protection (for IP65 see<br />
Optional-front plate), IP00 for contacts<br />
20 25 ■ 48 1<br />
0 2<br />
7 GN25 11 U 69.00 – Legend marking is per standard supplied, as<br />
32 32 ■ 65 7 GN32 11 U 79.00 illustrated in the catalog number table; any other on<br />
35 40 ■ 65 7 GN40 11 U 88.00 request.<br />
55 63 ■ 65 7 GN63 11 U 132.00 Selection guide<br />
100 125 ■ 90 7 GN125 11 U 334.00 See pages TC-34 and 35.<br />
Pole changing switches - 4 wafers - scheme 13.<br />
Optional<br />
10 12 ■ 48 7 GN12 13 U 70.00 IP65 front plate<br />
15 20 ■ 48 7 GN20 13 U 78.00 Add “51” at the end of the catalog number.<br />
20 25 ■ 48 0 2<br />
7 GN25 13 U 95.00 E.g. 7 GN12 11 U 51.<br />
32 32 ■ 65 7 GN32 13 U 110.00 Enlarged plate for GN12-20-25 (65x65 instead of 48x48)<br />
35 40 ■ 65 7 GN40 13 U 116.00 Add the letter “H” after the switch size of the catalog<br />
55 63 ■ 65 7 GN63 13 U 187.00 number.<br />
E.g. 7 GN12H 11 U.<br />
100 125 ■ 90 7 GN125 13 U 392.00<br />
Wye-delta switches - 4 wafers - scheme 12.<br />
Enlarged plate for GN32-40-63 (90x90 instead of 65x65)<br />
10 12 ■ 48 7 GN12 12 U 70.00 Add the letter “H” after the switch size of the catalog<br />
number.<br />
15 20 ■ 48 7 GN20 12 U 78.00 E.g. 7 GN32H 11 U.<br />
32 32 ■ 65 7 GN32 12 U 110.00 Special versions<br />
In addition to standard types, particular versions are<br />
35 40 ■ 65 7 GN40 12 U 116.00 available with special operating schemes.<br />
55 63 ■ 65 7 GN63 12 U 187.00 Contact Sales & Technical Support or complete the form;<br />
100 125 2■ 90 7 GN125 12 U 392.00 refer to the page just after TC-48.<br />
1<br />
0 2<br />
3-pole reversing switches with spring return to 0<br />
3 wafers - scheme 26.<br />
10 12 ■ 48 7 GN12 26 U 52.00<br />
1<br />
Y ∆<br />
15 20 ■ 48 7 GN20 26 U 59.00<br />
20 25 ■ 48 7 GN25 26 U 72.00<br />
Pole changing switches with reversing (Dahlander)<br />
6 wafers - scheme 20.<br />
10 12 ■ 48 0 7 GN12 20 U 88.00<br />
15 20 ■ 48 2 2 7 GN20 20 U 102.00<br />
20 25 ■ 48 7 GN25 20 U 128.00<br />
Front plate sizes<br />
48x48mm = 1.9x1.9in<br />
65x65mm = 2.6x2.6in<br />
90x90mm = 3.5x3.5in<br />
❶ See side table for UL horsepower ratings.<br />
1<br />
1<br />
UL horsepower ratings<br />
Max AC23A<br />
Type 1 phase 3 phase power<br />
at 440V<br />
120V 240V 120V 240V 480V 600V [kW]<br />
GN12 3 /4 1 1 1 /2 3 –– –– 6<br />
GN20 3 /4 2 1 1 /2 3 –– –– 7.5<br />
GN25 1 1 /2 3 3 5 10 10 11<br />
GN32 2 5 5 10 15 15 15<br />
GN40 2 5 5 10 20 20 18.5<br />
GN63 5 10 7 1 /2 15 25 25 30<br />
GN125 7 1 /2 15 15 25 50 40 45<br />
Certifications and compliance<br />
UL listed for USA, File E 155982.<br />
CSA certified for Canada and USA, File LR 207767.<br />
Compliant with standards: IEC/EN 60947-1,<br />
IEC/EN 60947-3, IEC/EN 60204-1, IEC/EN 61058-1.<br />
Accessories<br />
page 9-17<br />
Dimensions<br />
pages D-28<br />
Wiring diagrams<br />
page W-7<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com<br />
Technical characteristics<br />
pages TC-34 and 35
electric<br />
Rotary cam switches<br />
GN series<br />
9-11<br />
U version, front<br />
mounting.<br />
Voltmeter switches.<br />
Ammeter switches<br />
General Rated Front Catalog number Price<br />
purpose current plate<br />
AC21A size<br />
[A] [A] [mm] $ each<br />
VOLTMETER SWITCHES.<br />
Phase-Neutral L1-N/L2-N/L3-N<br />
2 wafers - scheme 68.<br />
10 12 ■ 48 0<br />
L1N 7 GN12 68 U 46.00<br />
15 20 ■ 48<br />
L3N<br />
7 GN20 68 U 51.00<br />
Phase-Phase L1-L2/L2-L3/L3-L1 -<br />
2 wafers - scheme 67.<br />
10 12 ■ 48 0<br />
L1-L2 7 GN12 67 U 46.00<br />
15 20 ■ 48<br />
L3-L1<br />
7 GN20 67 U 51.00<br />
For 3 phase to phase voltages and 3 phase voltages<br />
3 wafers - scheme 66.<br />
10 12 ■ 48 L1-L2<br />
0<br />
L1-N 7 GN12 66 U 71.00<br />
L2-L3<br />
15 20 ■ 48 L3-L1<br />
L3-N 7 GN20 66 U 78.00<br />
For 1 phase voltage and 3 phase to phase voltages<br />
3 wafers - scheme 60.<br />
10 12 ■ 48 0<br />
L1N L1-L2 7 GN12 60 U 71.00<br />
15 20 ■ 48 L3-L1 7 GN20 60 U 78.00<br />
AMMETER SWITCHES.<br />
Direct L1-L2-L3 reading - 5 wafers - scheme 97.<br />
10 12 ■ 48 0 7 GN12 97 U 73.00<br />
15 20 ■ 48 L3<br />
L1 7 GN20 97 U 80.00<br />
L1-L2-L3 reading via 3 current transformers -<br />
3 wafers - scheme 98.<br />
10 12 ■ 48 0 7 GN12 98 U 55.00<br />
15 20 ■ 48 L3<br />
L1 7 GN20 98 U 62.00<br />
L2<br />
L2N<br />
L2-L3<br />
L2-N<br />
L2-L3<br />
General characteristics<br />
– 12 and 20A capacity<br />
– Extended mechanical and electrical life<br />
– Switching angles: 30°, 45°, 60° and 90°<br />
- Silver-alloy dual-breaking contacts. Direct<br />
(positive-guided) opening operation ; safety<br />
function per IEC/EN 60947-5-1<br />
– Open type<br />
– IP40 front degree of protection (for IP65 see<br />
Optional-front plate), IP00 for contacts<br />
– Legend marking is per standard supplied, as<br />
illustrated in the catalog number table; any other on<br />
request.<br />
Selection guide<br />
See pages TC-34 and 35.<br />
Optional<br />
IP65 front plate<br />
Add “51” at the end of the catalog number.<br />
E.g. 7 GN12 67 U 51.<br />
Enlarged plate for GN12-20-25 (65x65 instead of 48x48)<br />
Add the letter “H” after the switch size of the catalog<br />
number.<br />
E.g. 7 GN20H 68 U.<br />
Special versions<br />
In addition to standard types, particular versions are<br />
available with special operating schemes.<br />
Contact Sales & Technical Support or complete the form;<br />
refer to the page just after TC-48.<br />
Certifications and compliance<br />
UL listed for USA, File E 155982.<br />
CSA certified for Canada and USA, File LR 207767.<br />
Compliant with standards: IEC/EN 60947-1,<br />
IEC/EN 60947-3, IEC/EN 60204-1, IEC/EN 61058-1.<br />
9<br />
L2<br />
Front plate sizes<br />
48x48mm = 1.9x1.9in<br />
65x65mm = 2.6x2.6in<br />
Accessories<br />
page 9-17<br />
Dimensions<br />
page D-28<br />
Wiring diagrams<br />
page W-8<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com<br />
Technical characteristics<br />
pages TC-34 and 35
9-12<br />
U11 version front<br />
mounting with<br />
handle operation<br />
for 22mm central<br />
fixing.<br />
On/Off switches<br />
Rotary cam switches<br />
GN series<br />
General Rated Front Catalog number Price<br />
purpose current plate<br />
AC21A size<br />
[A] [A] [mm] $ each<br />
ON/OFF SWITCHES. One pole - 1 wafer - scheme 90.<br />
10 12 none 0<br />
1<br />
7 GN12 90 U11 58.00<br />
15 20 none 7 GN20 90 U11 65.00<br />
Two poles - 1 wafer - scheme 91.<br />
10 12 none 0<br />
1<br />
7 GN12 91 U11 68.00<br />
15 20 none 7 GN20 91 U11 75.00<br />
electric<br />
General characteristics<br />
– 12 to 125A capacity<br />
– Extended mechanical and electrical life<br />
– Switching angles: 30°, 45°, 60° and 90°<br />
- Silver-alloy dual-breaking contacts. Direct<br />
(positive-guided) opening operation ; safety<br />
function per IEC/EN 60947-5-1<br />
– IP40 front degree of protection (for IP65 see<br />
Optional-front plate), IP00 for contacts and IP20 for<br />
incoming contacts of U25 and U65 only<br />
– Legend marking for U11 and U12 versions is for<br />
reference only while for U25 and U65 types standard<br />
supplied as illustrated in the catalog number table;<br />
any other on request.<br />
9<br />
Three poles - 2 wafers - scheme 10.<br />
10 12 none 0<br />
1<br />
7 GN12 10 U11 78.00<br />
15 20 none 7 GN20 10 U11 85.00<br />
Four poles - 2 wafers - scheme 92.<br />
10 12 none 0<br />
1<br />
7 GN12 92 U11 88.00<br />
15 20 none 7 GN20 92 U11 95.00<br />
U12 version front<br />
mounting with key<br />
operation for<br />
central fixing Ø22.<br />
On/Off switches<br />
0<br />
U25-U65 version<br />
front mounting<br />
with padlock<br />
system, red/yellow.<br />
On/Off switches<br />
Front plate sizes<br />
65x65mm = 2.6x2.6in<br />
90x90mm = 3.5x3.5in<br />
General Rated Front Catalog number Price<br />
purpose current plate<br />
AC21A size<br />
[A] [A] [mm] $ each<br />
ON/OFF SWITCHES. One pole - 1 wafer - circuit diagram 90.<br />
10 12 none<br />
1<br />
7 GN12 90 U12 62.00<br />
15 20 none 7 GN20 90 U12 69.00<br />
Two poles - 1 wafer - circuit diagram 91.<br />
10 12 none 0<br />
1<br />
7 GN12 91 U12 72.00<br />
15 20 none 7 GN20 91 U12 79.00<br />
Three poles - 2 wafers - circuit diagram 10.<br />
10 12 none 0<br />
1<br />
7 GN12 10 U12 82.00<br />
15 20 none 7 GN20 10 U12 89.00<br />
Four poles - 2 wafers - circuit diagram 92.<br />
10 12 none 0<br />
1<br />
7 GN12 92 U12 92.00<br />
15 20 none 7 GN20 92 U12 99.00<br />
General Rated Front Catalog number Price<br />
purpose current plate<br />
AC1 size<br />
[A] [A] [mm] $ each<br />
ON/OFF SWITCHES. Three poles - 2 wafers - scheme 10.<br />
10 12 ■ 65 7 GN12 10 U25 41.00<br />
15 20 ■ 65 7 GN20 10 U25 51.00<br />
20 25 ■ 65 0 7 GN25 10 U25 56.00<br />
32 32 ■ 65 7 GN32 10 U25 63.00<br />
35 40 ■ 65 7 GN40 10 U65 74.00<br />
55 63 ■ 65 7 GN63 10 U65 103.00<br />
100 125 ■ 90 7 GN125 10 U65 300.00<br />
Four poles - 2 wafers - scheme 92.<br />
10 12 ■ 65 7 GN12 92 U25 47.00<br />
15 20 ■ 65 7 GN20 92 U25 55.00<br />
20 25 ■ 65 0 7 GN25 92 U25 65.00<br />
32 32 ■ 65 7 GN32 92 U25 73.00<br />
35 40 ■ 65 7 GN40 92 U65 80.00<br />
55 63 ■ 65 7 GN63 92 U65 116.00<br />
100 125 ■ 90 7 GN125 92 U65 320.00<br />
1<br />
1<br />
Selection guide<br />
See pages TC-34 and 35.<br />
Optional<br />
IP65 front plate<br />
Add “51” at the end of the catalog number.<br />
E.g. 7 GN12 92 U25 51.<br />
Enlarged plate for GN32-40-63 (90x90 instead of 65x65)<br />
Add the letter “H” after the switch size of the catalog<br />
number.<br />
E.g. 7 GN32H 10 U25.<br />
Special versions<br />
In addition to standard types, particular versions are<br />
available with special operating circuit schemes.<br />
Contact Sales & Technical Support or complete the form;<br />
refer to the page just after TC-48.<br />
UL horsepower ratings<br />
Max AC23A<br />
Type 1 phase 3 phase power<br />
at 440V<br />
120V 240V 120V 240V 480V 600V [kW]<br />
GN12 3 /4 1 1 1 /2 3 –– –– 6<br />
GN20 3 /4 2 1 1 /2 3 –– –– 7.5<br />
GN25 1 1 /2 3 3 5 10 10 11<br />
GN32 2 5 5 10 15 15 15<br />
GN40 2 5 5 10 20 20 18.5<br />
GN63 5 10 7 1 /2 15 25 25 30<br />
GN125 7 1 /2 15 15 25 50 40 45<br />
Certifications and compliance<br />
UL listed for USA, File E 155982.<br />
CSA certified for Canada and USA, File LR 207767.<br />
Compliant with standards: IEC/EN 60947-1,<br />
IEC/EN 60947-3, IEC/EN 60204-1, IEC/EN 61058-1.<br />
Accessories<br />
page 9-17<br />
Dimensions<br />
page D-28<br />
Wiring diagrams<br />
page W-7<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com<br />
Technical characteristics<br />
pages TC-34 and 35
electric<br />
O88-O98-O99<br />
version, base<br />
mounting,<br />
door-coupling and<br />
padlock system,<br />
red/yellow.<br />
On/Off switches<br />
(without extension<br />
shaft)<br />
Rotary cam switches<br />
GN series<br />
General Rated Front Catalog number Price<br />
purpose current plate<br />
AC21A size<br />
[A] [A] [mm] $ each<br />
ON/OFF SWITCHES.<br />
3 poles - 2 wafers - scheme 10.<br />
10 12 ■ 65 7 GN12 10 O88 64.00<br />
15 20 ■ 65 7 GN20 10 O88 72.00<br />
20 25 ■ 65 0 7 GN25 10 O88 79.00<br />
32 32 ■ 65 7 GN32 10 O88 82.00<br />
35 40 ■ 65 7 GN40 10 O98 104.00<br />
55 63 ■ 65 7 GN63 10 O98 141.00<br />
100 125 ■ 90 7 GN125 10 O99 346.00<br />
4 poles - 2 wafers - scheme 92.<br />
10 12 ■ 65 7 GN12 92 O88 68.00<br />
15 20 ■ 65 7 GN20 92 O88 75.00<br />
20 25 ■ 65 0 7 GN25 92 O88 82.00<br />
32 32 ■ 65 7 GN32 92 O88 90.00<br />
35 40 ■ 65 7 GN40 92 O98 116.00<br />
55 63 ■ 65 7 GN63 92 O98 150.00<br />
100 125 ■ 90 7 GN125 92 O99 387.00<br />
Front plate sizes<br />
45x45mm = 1.9x1.9in<br />
65x65mm = 2.6x2.6in<br />
90x90mm = 3.5x3.5in<br />
1<br />
1<br />
9-13<br />
General characteristics<br />
– 12 to 125A capacity<br />
– Extended mechanical and electrical life<br />
– Switching angles: 30°, 45°, 60° and 90°<br />
- Silver-alloy dual-breaking contacts. Direct<br />
(positive-guided) opening operation ; safety<br />
function per IEC/EN 60947-5-1<br />
– Open type<br />
– IP40 front degree of protection (for IP65 see<br />
Optional-front plate), IP20 for incoming contacts only<br />
– Self alignment feature<br />
– Legend marking is per standard supplied, as<br />
illustrated in the catalog number table; any other on<br />
request.<br />
Selection guide<br />
See pages TC-34 and 35.<br />
Optional<br />
IP65 front plate<br />
Add “51” at the end of the catalog number.<br />
E.g. 7 GN12 92 068 51.<br />
Fixing plate for DIN 35mm rail (IEC/EN 60715)<br />
Add “18” at the end of the catalog number.<br />
E.g. 7 GN25 10 O68 18.<br />
Enlarged plate for GN12-20-25 (65x65 instead of 48x48)<br />
Add the letter “H” after the switch size of the catalog<br />
number.<br />
E.g. 7 GN12H 10 O68.<br />
O68-O78-O79<br />
version, base<br />
mounting,<br />
door-coupling<br />
system.<br />
On/Off switches<br />
(without extension<br />
shaft)<br />
0<br />
General Rated Front Catalog number Price<br />
purpose current plate<br />
AC21A size<br />
[A] [A] [mm] $ each<br />
ON/OFF SWITCHES.<br />
3 poles - 2 wafers - scheme 10.<br />
10 12 ■ 48 7 GN12 10 O68 62.00<br />
15 20 ■ 48 7 GN20 10 O68 67.00<br />
20 25 ■ 48 7 GN25 10 O68 75.00<br />
32 32 ■ 65 7 GN32 10 O68 80.00<br />
35 40 ■ 65 7 GN40 10 O78 99.00<br />
55 63 ■ 65 7 GN63 10 O78 135.00<br />
100 125 ■ 90 7 GN125 10 O79 351.00<br />
4 poles - 2 wafers - scheme 92.<br />
10 12 ■ 48 7 GN12 92 O68 66.00<br />
15 20 ■ 48 7 GN20 92 O68 72.00<br />
20 25 ■ 48 0 7 GN25 92 O68 79.00<br />
32 32 ■ 65 7 GN32 92 O68 85.00<br />
35 40 ■ 65 7 GN40 92 O78 114.00<br />
55 63 ■ 65 7 GN63 92 O78 148.00<br />
100 125 ■ 90 7 GN125 92 O79 382.00<br />
Front plate sizes<br />
45x45mm = 1.9x1.9in<br />
65x65mm = 2.6x2.6in<br />
90x90mm = 3.5x3.5in<br />
1<br />
1<br />
Enlarged plate for GN32-40-63 (90x90 instead of 65x65)<br />
Add the letter “H” after the switch size of the catalog<br />
number.<br />
E.g. 7 GN32H 10 O68.<br />
Special versions<br />
In addition to standard types, particular versions are<br />
available with special operating schemes.<br />
Contact Sales & Technical Support or complete the form;<br />
refer to the page just after TC-48.<br />
UL horsepower ratings<br />
Max AC23A<br />
Type 1 phase 3 phase power<br />
at 440V<br />
120V 240V 120V 240V 480V 600V [kW]<br />
GN12 3 /4 1 1 1 /2 3 –– –– 6<br />
GN20 3 /4 2 1 1 /2 3 –– –– 7.5<br />
GN25 1 1 /2 3 3 5 10 10 11<br />
GN32 2 5 5 10 15 15 15<br />
GN40 2 5 5 10 20 20 18.5<br />
GN63 5 10 7 1 /2 15 25 25 30<br />
GN125 7 1 /2 15 15 25 50 40 45<br />
Certifications and compliance<br />
UL listed for USA, File E 155982.<br />
CSA certified for Canada and USA, File LR 207767.<br />
Compliant with standards: IEC/EN 60947-1,<br />
IEC/EN 60947-3, IEC/EN 60204-1, IEC/EN 61058-1.<br />
9<br />
Accessories<br />
page 9-17<br />
Dimensions<br />
page D-28<br />
Wiring diagrams<br />
page W-7<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com<br />
Technical characteristics<br />
pages TC-34 and 35
9-14<br />
Rotary cam switches<br />
GN series<br />
electric<br />
9<br />
P version, enclosed<br />
On/Off switches.<br />
Double-throw<br />
switches<br />
General characteristics<br />
0 2<br />
General Rated Type Catalog number Price<br />
20 25 90x90<br />
1<br />
7 GN25 75 P 165.00<br />
purpose current size<br />
AC21A<br />
– 12 to 63A capacity<br />
– Extended mechanical and electrical life<br />
[A] [A] [mm] $ each – Switching angles: 30°, 45°, 60° and 90°<br />
- Silver-alloy dual-breaking contacts. Direct<br />
ON/OFF SWITCHES.<br />
(positive-guided) opening operation ; safety<br />
Three poles - scheme 10.<br />
function per IEC/EN 60947-5-1<br />
10 12 65x65 7 GN12 10 P 115.00 – Enclosed type<br />
15 20 75x75 7 GN20 10 P 124.00 – IP65 degree of protection (IP54 for GN12 only)<br />
0<br />
– Top and bottom entry:<br />
1<br />
20 25 75x75 7 GN25 10 P 130.00 • 4 PG11 threaded knockouts for 65x65mm types<br />
32 32 90x90 7 GN32 10 P 136.00 • 4 PG13.5 threaded knockouts for 75x75mm types<br />
35 40 90x90 7 GN40 10 P 144.00 • 4 PG16 threaded knockouts for 90x90mm types<br />
• 4 PG21 threaded knockouts for 110x110mm types<br />
55 63 110x110 7 GN63 10 P 212.00 – NPT adapters are given on page 9-17; metric entry<br />
Four poles - scheme 92.<br />
available on request<br />
10 12 65x65 7 GN12 92 P 126.00 – Legend marking is per standard supplied, as<br />
illustrated in the catalog number table; any other on<br />
15 20 75x75 7 GN20 92 P 132.00<br />
0<br />
request.<br />
1<br />
20 25 75x75 7 GN25 92 P 142.00<br />
32 32 90x90 7 GN32 92 P 150.00 Selection guide<br />
See pages TC-34 and 35.<br />
35 40 90x90 7 GN40 92 P 161.00<br />
55 63 110x110 7 GN63 92 P 232.00 Special versions<br />
DOUBLE-THROW SWITCHES.<br />
In addition to standard types, particular versions are<br />
One pole - scheme 51.<br />
available with special operating schemes.<br />
Contact Sales & Technical Support or complete the form;<br />
10 12 65x65 7 GN12 51 P 120.00 refer to the page just after TC-48.<br />
15 20 75x75 7 GN20 51 P 126.00<br />
1<br />
0<br />
20 25 75x75 2<br />
UL horsepower ratings<br />
Max AC23A<br />
7 GN25 51 P 132.00<br />
Type 1 phase 3 phase power<br />
32 32 90x90 7 GN32 51 P 140.00<br />
at 440V<br />
120V 240V 120V 240V 480V 600V<br />
35 40 90x90 7 GN40 51 P 146.00<br />
[kW]<br />
55 63 110x110 7 GN63 51 P 221.00 GN12 3 /4 1 1 1 /2 3 –– –– 6<br />
Two poles - scheme 52.<br />
GN20 3 /4 2 1 1 /2 3 –– –– 7.5<br />
10 12 65x65 7 GN12 52 P 128.00 GN25 1 1 /2 3 3 5 10 10 11<br />
15 20 75x75 7 GN20 52 P 133.00 GN32 2 5 5 10 15 15 15<br />
20 25 75x75<br />
1<br />
0 2<br />
7 GN25 52 P 142.00 GN40 2 5 5 10 20 20 18.5<br />
32 32 90x90 7 GN32 52 P 153.00 GN63 5 10 7 1 /2 15 25 25 30<br />
35 40 90x90 7 GN40 52 P 162.00 Certifications and compliance<br />
55 63 110x110 7 GN63 52 P 241.00 UL listed for USA, File E 155982.<br />
Three poles - scheme 53.<br />
CSA certified for Canada and USA, File LR 207767.<br />
Compliant with standards: IEC/EN 60947-1,<br />
10 12 65x65 7 GN12 53 P 136.00 IEC/EN 60947-3, IEC/EN 60204-1, IEC/EN 61058-1.<br />
15 20 75x75 7 GN20 53 P 142.00<br />
20 25 75x75<br />
1<br />
0 2<br />
7 GN25 53 P 152.00<br />
32 32 90x90 7 GN32 53 P 167.00<br />
35 40 110x110 7 GN40 53 P 178.00<br />
55 63 110x110 7 GN63 53 P 253.00<br />
Four poles - scheme 75.<br />
10 12 65x65 7 GN12 75 P 144.00<br />
15 20 75x75 7 GN20 75 P 149.00<br />
32 32 90x90 7 GN32 75 P 179.00<br />
35 40 110x110 7 GN40 75 P 193.00<br />
55 63 110x110 7 GN63 75 P 275.00<br />
Enclosure type sizes<br />
65x65mm = 2.6x2.6in<br />
75x75mm = 3x3in<br />
90x90mm = 3.5x3.5in<br />
110x110mm = 4.3x4.3in<br />
Accessories<br />
page 9-17<br />
Dimensions<br />
page D-28<br />
Wiring diagrams<br />
page W-7<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com<br />
Technical characteristics<br />
pages TC-34 and 35
electric<br />
P with rotating<br />
handle version in<br />
enclosure.<br />
Motor switches<br />
Rotary cam switches<br />
GN series<br />
General Rated Front Catalog number Price<br />
purpose current plate<br />
AC21A size<br />
[A] [A] [mm] $ each<br />
MOTOR SWITCHES❶.<br />
Three-pole reversing switches - circuit scheme 11.<br />
10 12 65x65 7 GN12 11 P 134.00<br />
15 20 75x75 7 GN20 11 P 145.00<br />
20 25 75x75<br />
0 2<br />
7 GN25 11 P 156.00<br />
32 32 90x90 7 GN32 11 P 166.00<br />
35 40 110x110 7 GN40 11 P 176.00<br />
55 63 110x110 7 GN63 11 P 220.00<br />
❶ See side table for UL horsepower ratings.<br />
9-15<br />
General characteristics<br />
– 12 to 32A capacity<br />
– Extended mechanical and electrical life<br />
– Switching angles: 30°, 45°, 60° and 90°<br />
- Silver-alloy dual-breaking contacts. Direct<br />
(positive-guided) opening operation ; safety<br />
function per IEC/EN 60947-5-1<br />
– Enclosed type<br />
– IP65 degree of protection<br />
– Top and bottom entry:<br />
• 4 PG11 threaded knockouts for 65x65mm types<br />
• 4 PG13.5 threaded knockouts for 75x75mm types<br />
• 4 PG16 threaded knockouts for 90x90mm types<br />
• 4 PG21 threaded knockouts for 110x110mm types<br />
– NPT adapters are given on page 9-17; metric entry<br />
available on request<br />
– Legend marking is per standard supplied, as<br />
illustrated in the catalog number table; any other on<br />
request.<br />
P25 version in<br />
enclosure with<br />
padlock system.<br />
On/Off switches<br />
General Rated Type Catalog number Price<br />
purpose current size<br />
AC21A<br />
[A] [A] [mm] $ each<br />
ON/OFF SWITHCES.<br />
Three poles - scheme 10.<br />
15 20 90x90 0<br />
1<br />
7 GN20 10 P25 130.00<br />
20 25 90x90 7 GN25 10 P25 139.00<br />
32 32 90x90 7 GN32 10 P25 145.00<br />
Four poles - scheme 92.<br />
15 20 90x90 0<br />
1<br />
7 GN20 92 P25 136.00<br />
20 25 90x90 7 GN25 92 P25 148.00<br />
32 32 90x90 7 GN32 92 P25 156.00<br />
Enclosure type size:<br />
65x65mm = 2.6x2.6in<br />
75x75mm = 3x3in<br />
90x90mm = 3.5x3.5in<br />
110x110mm = 4.3x4.3in<br />
1<br />
UL horsepower ratings Max AC23A<br />
Selection guide<br />
See pages TC-34 and 35.<br />
Special versions<br />
In addition to standard types, particular versions are<br />
available with special operating schemes.<br />
Contact Sales & Technical Support or complete the form;<br />
refer to the page just after TC-48.<br />
Type 1 phase 3 phase power<br />
at 440V<br />
120V 240V 120V 240V 480V 600V [kW]<br />
GN12 3 /4 1 1 1 /2 3 –– –– 6<br />
GN20 3 /4 2 1 1 /2 3 –– –– 7.5<br />
GN25 1 1 /2 3 3 5 10 10 11<br />
GN32 2 5 5 10 15 15 15<br />
GN40 2 5 5 10 20 20 18.5<br />
GN63 5 10 7 1 /2 15 25 25 30<br />
Certifications and compliance<br />
UL listed for USA, File E 155982.<br />
CSA certified for Canada and USA, File LR 207767.<br />
Compliant with standards: IEC/EN 60947-1,<br />
IEC/EN 60947-3, IEC/EN 60204-1, IEC/EN 61058-1.<br />
9<br />
Accessories<br />
page 9-17<br />
Dimensions<br />
page D-28<br />
Wiring diagrams<br />
page W-7<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com<br />
Technical characteristics<br />
pages TC-34 and 35
9-16<br />
Rotary cam switches<br />
Accessories for GX series<br />
electric<br />
9<br />
7 A014 - 7 AR114 - 7 AR214<br />
7 AR124 - 7 AR224<br />
7 APRBP<br />
GX M1 - GX M2<br />
Description Catalog Price<br />
number<br />
$ each<br />
Black operating handle ❶.<br />
For 48x48mm front plate 7 AO14 2.10<br />
For GX32-GX40 65x65mm 7 A114 4.20<br />
front plate<br />
For GX16-GX20 65x65mm 7 AR114 4.20<br />
front plate<br />
For GX32-GX40 90x90mm 7 AR214 5.50<br />
front plate<br />
Black operating lever ❶.<br />
For GX32-GX40 65x65mm 7 A124 5.50<br />
front plate<br />
For GX16-GX20 65x65mm 7 AR124 5.50<br />
front plate<br />
For GX32-GX40 90x90mm 7 AR224 8.00<br />
front plate<br />
Adjustable door-coupling extension shaft, 70mm (2.8in) long<br />
maximum ❶.<br />
For GX16 to GX40 7 APRBP 5.50<br />
IP40 face plates ❶.<br />
48x48mm blank face plate GX M1 3.00<br />
65x65mm blank face plate GX M2 4.50<br />
IP40 face plates with legend plates.<br />
48x48mm blank face plate GX M5 4.60<br />
with legend plate<br />
65x65mm blank face plate GX M6 4.60<br />
with legend plate<br />
Padlockable handles ❶.<br />
48x48mm yellow/red GX A01 10.30<br />
padlockable handle for<br />
GX16-GX20<br />
65x65mm yellow/red GX A01H 12.20<br />
padlockable handle for<br />
GX16-GX20<br />
65x65mm yellow/red GX A11 12.20<br />
padlockable handle for<br />
GX32-GX40<br />
PG adapter for enclosure entries ❶.<br />
Metal, for PG16 to 1 /2” NPT G616 3.00<br />
Metal, for PG21 to 1 /2” NPT G621 3.00<br />
Plastic, for PG16 to 1 /2” NPT G617 2.50<br />
Plastic, for PG21 to 1 /2” NPT G622 2.50<br />
For operating handle or lever, plate dimension:<br />
45x45mm = 1.9x1.9in<br />
65x65mm = 2.6x2.6in<br />
90x90mm = 3.5x3.5in<br />
❶ Also suitable for GN series.<br />
GX M5 - GX M6<br />
GX A01 - GX A01H - GX A11<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com
electric<br />
Rotary cam switches<br />
Accessories for GN series<br />
9-17<br />
7 A019...<br />
7 A119...<br />
7 AO14<br />
7 AR114<br />
7 AR214<br />
7 A180 - 7 A181<br />
7 APRBP<br />
7 A169...<br />
7 A441 - 7 A442 - 7 A443<br />
GX M1 - GX M2<br />
7 AR124<br />
7 AR224<br />
GX A01 - GX A01H - GX A11<br />
Description Catalog Price<br />
number<br />
$ each<br />
Finger protection covers for supply terminals.<br />
For GN12-GN20 7 A0191 2.80<br />
For GN25 7 A0192 2.80<br />
For GN32 U version 7 A119U 2.80<br />
For GN32 O version 7 A119O 2.80<br />
For GN40 7 A1691 3.50<br />
For GN63 7 A1692 3.50<br />
For GN125 7 A1693 3.50<br />
Black operating handle ❶.<br />
For 48x48mm front plate 7 AO14 2.10<br />
For GN32 - GN40 - GN63 65x65mm 7 A114 4.20<br />
front plate<br />
For GN12 - GN20 - GN25 65x65mm 7 AR114 4.20<br />
front plate<br />
For GN32 - GN40 - GN63 - GN125 7 AR214 5.50<br />
90x90mm front plate<br />
Black operating lever ❶.<br />
For GN32 - GN40 - GN63 65x65mm 7 A124 5.50<br />
front plate<br />
For GN12 - GN20 - GN25 65x65mm 7 AR124 5.50<br />
front plate<br />
For GN32 - GN40 - GN63 - GN125 7 AR224 8.00<br />
90x90mm front plate<br />
35mm DIN rail (IEC/EN 60715) base mounting piece<br />
for U version.<br />
For GN12 to GN25 7 A180 3.50<br />
For GN32 to GN63 7 A181 4.50<br />
Adjustable door-coupling extension shaft,<br />
70 mm (2.8in) long maximum ❶.<br />
For GN12 to GN63 7 APRBP 5.50<br />
Flexible rubber boot ❷.<br />
Ø 58mm (2.3in), 70mm (2.8in) 7 A441 9.00<br />
long for GN12 to GN25 with 2 wafers<br />
Ø 58mm (2.3in), 92mm (3.6in) 7 A442 10.00<br />
long for GN12 to GN25 with 4 wafers<br />
Ø 58mm (2.3in), 125mm (4.9in), 7 A443 11.00<br />
for GN12 to GN25 with 6 wafers<br />
IP40 face plates ❶.<br />
48x48mm blank face plate GX M1 3.00<br />
65x65mm blank face plate GX M2 4.50<br />
Padlockable handles ❶.<br />
48x48mm yellow/red padlockable GX A01 10.30<br />
handle for GN12-GN20-GN25<br />
65x65mm yellow/red padlockable GX A01H 12.20<br />
handle for GN12-GN20-GN25<br />
65x65mm yellow/red padlockable GX A11 12.20<br />
handle for GN32-GN40-GN63<br />
PG adapters for enclosure entries ❶.<br />
Metal, for PG11 to 1 /2” NPT G611 2.50<br />
Metal, for PG13.5 to 1 /2” NPT G613 2.50<br />
Metal, for PG16 to 1 /2” NPT G616 3.00<br />
Metal, for PG21 to 1 /2” NPT G621 3.00<br />
Plastic, for PG11 to 1 /2” NPT G612 1.50<br />
Plastic, for PG13.5 to 1 /2” NPT G614 1.50<br />
Plastic, for PG16 to 1 /2” NPT G617 2.50<br />
Plastic, for PG21 to 1 /2” NPT G622 2.50<br />
For operating handle or lever, plate dimension:<br />
45x45mm = 1.9x1.9in<br />
65x65mm = 2.6x2.6in<br />
90x90mm = 3.5x3.5in<br />
❶ Also suitable for GX series.<br />
❷ Raises contact degree of protection from IP00 to IP20.<br />
9<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com
MODULAR TIMERS<br />
• Internal panel mounting<br />
• Time ranges: 0.1 second - 100 days<br />
• LED indication<br />
• Mounting on 35mm DIN rail<br />
• Screw terminals.<br />
PAGE 10-2<br />
PAGE 10-4<br />
DIN RAIL MOUNT TIMERS<br />
• Internal panel mounting<br />
• Time ranges: 0.3 seconds - 768 minutes<br />
• LED indication<br />
• Mounting on 35mm DIN rail<br />
• Screw terminals.<br />
PAGE 10-8<br />
PLUG-IN AND FLUSH-MOUNT TIMERS, 48x48mm<br />
• Flush and internal panel mounting<br />
• Time ranges: 0.05 second - 10 hours<br />
• LED indication<br />
• 8 and 11-pin sockets for panel mounting.<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com
10<br />
TIMERS<br />
Modular type<br />
Plug-in (8 pin and 11 pin) or<br />
flush-mount 48x48mm type<br />
DIN rail mount type<br />
Rugged, reliable, high repeat<br />
accuracy<br />
Multi-voltage, single-scale,<br />
single-fuction versions<br />
Multi-voltage, multi-scale and<br />
multi-function versions.<br />
PLANET -DIN<br />
SEC. PAGE<br />
Modular timers<br />
On delay, multiscale, multivoltage, AC/DC supply . . . . . . . . . . . . . . . . . . . . . . . . . . 10- 2<br />
Multifunction, multiscale, multivoltage, 1 double-throw contact . . . . . . . . . . . . . . 10- 2<br />
Multifunction, multiscale, multivoltage, 1 double-throw and 1 normally<br />
open contacts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10- 2<br />
Asymmetrical recycle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10- 3<br />
Off delay, multiscale, AC/DC supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10- 3<br />
For starters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10- 3<br />
For staircases, AC supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10- 4<br />
DIN rail mount timers<br />
On delay, multiscale, AC supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10- 4<br />
On delay, multiscale, AC/DC supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10- 4<br />
Off delay, multiscale, AC/DC supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10- 5<br />
Multifunction, multiscale, multivoltage, 1 double-throw contact . . . . . . . . . . . . . . 10- 5<br />
Multifunction, multiscale, multivoltage, 2 independent double-throw contacts . . . 10- 6<br />
Asymmetrical recycle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10- 6<br />
For starters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10- 7<br />
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10- 7<br />
Plug-in and flush-mount timers<br />
On delay, multiscale, multivoltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10- 8<br />
On delay, multiscale, single voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10- 8<br />
Multifunction, multiscale, multivoltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10- 8<br />
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10- 9<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com
10-2 Timers<br />
electric<br />
Modular timers<br />
On delay.<br />
Multiscale.<br />
AC/DC supply<br />
Time of Control Catalog number Price<br />
scale range power<br />
[V]<br />
$ each<br />
0.1-1s 24-48VDC TM P 59.00<br />
1-10s 24-240VAC<br />
6s-1min<br />
1-10min<br />
6min-1h<br />
1h-10h<br />
0.1-1 day<br />
1-10 days<br />
ON only<br />
OFF only<br />
General characteristics<br />
– Multiscale, multivoltage.<br />
On delay, delay on make, with start at relay energizing<br />
– One relay output with 1 SPDT contact<br />
– Delay time adjustable on front by rotary switch:<br />
10-100%<br />
– Green LED indicator for power on<br />
– Red LED indicator for relay state; flashing for delay<br />
and steady when relay energized<br />
– Modular 17.5mm (0.7in) wide; suitable for screw<br />
fixing or 35mm DIN rail (IEC/EN 60715) mounting<br />
– Degree of protection: IP40 on front (only when<br />
mounted in housing or electric board with IP40);<br />
IP20 on terminals.<br />
TM P<br />
Certifications and compliance<br />
UL listed for USA and Canada, file E93601.<br />
Compliant with standards: IEC/EN 61812-1.<br />
Operational diagram<br />
See page W-8.<br />
10<br />
Multifunction.<br />
Multiscale.<br />
AC/DC supply.<br />
1 relay output<br />
TM M1<br />
Multifunction.<br />
Multiscale.<br />
AC/DC supply.<br />
2 relay outputs<br />
Time of Control Catalog number Price<br />
scale range power<br />
[V]<br />
$ each<br />
0.1-1s 12-240V TM M1 79.00<br />
1-10s AC/DC<br />
6s-1min<br />
1-10min<br />
6min-1h<br />
1h-10h<br />
0.1-1 day<br />
1-10 days<br />
ON only<br />
OFF only<br />
Time of Control Catalog number Price<br />
scale range power<br />
[V]<br />
$ each<br />
0.1-1s 12-240V TM M2 89.00<br />
1-10s AC/DC<br />
6s-1min<br />
1-10min<br />
6min-1h<br />
1h-10h<br />
0.1-1 day<br />
1-10 days<br />
ON only<br />
OFF only<br />
General characteristics<br />
– Multifunction, multiscale, multivoltage<br />
– Enabling input<br />
– One relay output with 1 SPDT contact for TM M1<br />
– Two relay outputs, one with 1 delayed SPDT contact<br />
and the other with 1 normally open (N/O) contact,<br />
programmable as instantaneous or delayed for TM M2<br />
– Selectable functions: (a) On delay; delay on make with<br />
start at relay energizing. (b) Pulse on relay energizing<br />
with start when energized. (c) Flasher starting with OFF<br />
interval. Equal timing recycle. (d) Flasher starting with<br />
ON interval. Equal timing recycle. (e) Off delay; relay<br />
energizing at external contact closing with start on<br />
break. (f) Pulse on relay energizing with start on<br />
external contact closing. (g) Pulse on relay energizing<br />
with start on external contact opening. (h) On-off<br />
delay. Delay on make, with start at external contact<br />
closing, and delay at break, with start at external<br />
contact opening. (i) Step relay at each closing of an<br />
external contact. (j) Pulse generator, unequal timing<br />
recycle; starting with OFF pulse time and 0.5s ON<br />
pulse.<br />
– Delay time adjustable on front by rotary switch:<br />
10-100%<br />
– Green LED indicator for power on<br />
– Red LED indicator for relay state; flashing for delay<br />
and steady when relay energised<br />
– Modular 17.5mm (0.7in) wide; suitable for screw fixing<br />
or 35mm DIN rail (IEC/EN 60715) mounting<br />
– Degree of protection: IP40 on front (only when<br />
mounted in housing or electric board with IP40);<br />
IP20 on terminals.<br />
Certifications and compliance<br />
UL listed for USA and Canada, file E93601.<br />
Compliant with standards: IEC/EN 61812-1.<br />
Operational diagram<br />
See page W-8 for TM M1 and W-9 for TM M2.<br />
TM M2<br />
Dimensions<br />
page D-29<br />
Wiring diagrams<br />
pages W-8 and 9<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com<br />
Technical characteristics<br />
page TC-38
electric<br />
Asymmetrical<br />
recycle, independent<br />
timing.<br />
Multiscale.<br />
AC/DC supply<br />
TM PL<br />
Timers<br />
Modular timers<br />
Time of Control Catalog number Price<br />
scale range power<br />
[V]<br />
$ each<br />
0.1-1s 12-240V TM PL 150.00<br />
1-10s AC/DC<br />
6s-1min<br />
1-10min<br />
6min-1h<br />
1h-10h<br />
0.1-1 day<br />
1-10 days<br />
3-30 days<br />
10-100 days<br />
10-3<br />
General characteristics<br />
– Programmable asymmetrical recycle, multiscale,<br />
multivoltage. Flasher with independent timing for ON<br />
and OFF intervals<br />
– Enabling input of ON or OFF interval<br />
– One relay output with 1 SPDT contact<br />
– Delay time for OFF (pause) interval, adjustable on<br />
front by rotary switch: 10-100%<br />
– Delay time for ON (work) interval, adjustable on front<br />
by rotary switch: 10-100%<br />
– Green LED indicator for power on<br />
– Red LED indicator for relay state; flashing for delay<br />
– Modular 17.5mm (0.7in) wide; suitable for screw<br />
fixing or 35mm DIN rail (IEC/EN 60715) mounting<br />
– Degree of protection: IP40 on front (only when<br />
mounted in housing or electric board with IP40);<br />
IP20 on terminals.<br />
Certifications and compliance<br />
UL listed for USA and Canada, file E93601.<br />
Compliant with standards: IEC/EN 61812-1.<br />
Operational diagram<br />
See page W-9.<br />
Off delay.<br />
Multiscale.<br />
AC/DC supply<br />
Time of Control Catalog number Price<br />
scale range power<br />
[V]<br />
$ each<br />
0.06-0.6s 24-240V TM D 147.00<br />
0.6-6s AC/DC<br />
6s-1min<br />
12s-2min<br />
General characteristics<br />
– Multiscale, multivoltage. True off delay; delay on break<br />
with start at relay de-energizing<br />
– One relay output with 1 SPDT contact<br />
– Delay time adjustable on front by rotary switch:<br />
10-100%<br />
– Green LED indicator for power on<br />
– Modular 17.5mm (0.7in) wide; suitable for screw<br />
fixing or 35mm DIN rail (IEC/EN 60715) mounting<br />
– Degree of protection: IP40 on front (only when<br />
mounted in housing or electric board with IP40);<br />
IP20 on terminals.<br />
Certifications and compliance<br />
UL listed for USA and Canada, file E93601.<br />
Compliant with standards: IEC/EN 61812-1.<br />
TM D<br />
Operational diagram<br />
See page W-9.<br />
10<br />
Timer for<br />
starters.<br />
Multiscale.<br />
AC/DC supply<br />
TM ST<br />
Time of Control Catalog number Price<br />
scale range power<br />
[V]<br />
$ each<br />
0.1-1s 24-48VDC TM ST 106.00<br />
1-10s 24-240VAC<br />
6s-1min<br />
1-10min<br />
380-440VAC TM ST A440 106.00<br />
General characteristics<br />
– Multiscale, multivoltage for starting (wye-delta,<br />
impedance, autotransformer, etc.) of induction<br />
motors, 2 separate timings<br />
– One relay output with 2 normally open (N/O) contacts<br />
with common pole<br />
– Delay time adjustable on front by rotary switch:<br />
10-100% for wye connection<br />
– Starting and transition time (20-300ms time scale),<br />
adjustable on front by rotary switch<br />
– Green LED indicator for power on<br />
– Red LED indicator for relay state; flashing during<br />
delay and steady at delay lapsing<br />
– Modular 17.5mm (0.7in) wide; suitable for screw<br />
fixing or 35mm DIN rail (IEC/EN 60715) mounting<br />
– Degree of protection: IP40 on front (only when<br />
mounted in housing or electric board with IP40);<br />
IP20 on terminals.<br />
Certifications and compliance<br />
UL listed for USA and Canada, file E93601.<br />
Compliant with standards: IEC/EN 61812-1.<br />
Operational diagram<br />
See page W-10.<br />
Dimensions<br />
page D-29<br />
Wiring diagrams<br />
pages W-9 and 10<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com<br />
Technical characteristics<br />
page TC-38
10-4 Timers<br />
electric<br />
Modular timers. DIN rail mount timers<br />
For staircases.<br />
AC supply<br />
TM LS<br />
Time of Control Catalog number Price<br />
scale range power<br />
[V]<br />
$ each<br />
0.5-20min 220-240VAC TM LS 75.00<br />
General characteristics<br />
– Single scale and voltage for staircase illumination<br />
– One relay output with 1 powered normally open (N/O)<br />
contact<br />
– Delay time adjustable on front by rotary switch<br />
– Suitable for 3 or 4-wire systems<br />
– 1 slide switch for timed or constant operation<br />
– Function for 1-hour lighting and quick switch off<br />
– Green LED indicator for power on<br />
– Connection with up to 50 light-up switches maximum;<br />
≤ 1mA each<br />
– Modular 17.5mm (0.7in) wide; suitable for screw<br />
fixing or 35mm DIN rail (IEC/EN 60715) mounting<br />
– Degree of protection: IP40 on front (only when<br />
mounted in housing or electric board with IP40);<br />
IP20 on terminals.<br />
Certifications and compliance<br />
UL listed for USA and Canada, file E93601.<br />
Compliant with standards: IEC/EN 61812-1.<br />
Operational diagram<br />
See page W-10.<br />
On delay.<br />
Multiscale.<br />
AC supply<br />
Time of Control Catalog number Price<br />
scale range power ❶<br />
[V]<br />
$ each<br />
0.3-3s 24VAC 31 AT1P 240 68.00<br />
1.2-12s 100-240VAC<br />
9.6-96s 24VAC 31 AT1P 440 68.00<br />
76.8-768s 220-440VAC<br />
❶ For 31 AT1 single-scale types, contact Sales & Technical Support.<br />
General characteristics<br />
– On delay, multivoltage, multiscale<br />
– One output with 1 SPDT contact<br />
– Delay time adjustable on front using potentiometer<br />
– Time scale setting using dip switches<br />
– LED indication for power on and relay state<br />
– 22.5mm (0.9in) wide housing suitable for mounting<br />
on 35mm DIN rail (IEC/EN 60715)<br />
– Screw fixing adapter CE106.<br />
31 AT1P<br />
Time-range setting<br />
ON<br />
2<br />
1<br />
ON<br />
2<br />
1<br />
ON<br />
2<br />
1<br />
ON<br />
2<br />
1<br />
0.3-3s 1.2-12s 9.6-96s 76.8-768s<br />
Certifications and compliance<br />
UL listed for USA and Canada, file E93601.<br />
Compliant with standards: IEC/EN 61812-1.<br />
Operational diagram<br />
See page W-10.<br />
10<br />
On delay.<br />
Multiscale.<br />
AC/DC supply<br />
Time of Control Catalog number Price<br />
scale range power ❷<br />
[V]<br />
$ each<br />
12VAC/DC 31 AT1CP 24 68.00<br />
0.3-3s 24VAC/DC<br />
1.2-12s<br />
9.6-96s 48-60VAC/DC 31 AT1CP 125 68.00<br />
76.8-768s 110-125V<br />
AC/DC<br />
General characteristics<br />
– On delay, multivoltage, multiscale<br />
– One output with 1 SPDT contact<br />
– Delay time adjustable on front using potentiometer<br />
– Time scale setting using dip switches<br />
– LED indication for power on and relay state<br />
– 22.5mm (0.9in) wide housing suitable for mounting<br />
on 35mm DIN rail (IEC/EN 60715)<br />
– Screw fixing adapter CE106.<br />
31 AT1CP<br />
❷ For 31 AT1C single-scale types, contact Sales & Technical Support.<br />
Time-range setting<br />
ON<br />
2<br />
1<br />
ON<br />
2<br />
1<br />
ON<br />
2<br />
1<br />
ON<br />
2<br />
1<br />
0.3-3s 1.2-12s 9.6-96s 76.8-768s<br />
Certifications and compliance<br />
UL listed for USA and Canada, file E93601.<br />
Compliant with standards: IEC/EN 61812-1.<br />
Operational diagram<br />
See page W-10.<br />
Accessories<br />
pages 10-7<br />
Dimensions<br />
page D-29<br />
Wiring diagrams<br />
page W-10<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com<br />
Technical characteristics<br />
pages TC-36 and 38
electric<br />
Timers<br />
DIN rail mount timers<br />
10-5<br />
Off delay.<br />
Multiscale<br />
Time of Control Catalog number Price<br />
scale range power<br />
[V]<br />
$ each<br />
0.3-3s<br />
24VAC/DC 31 ATD 24 180.00<br />
1.2-12s 48VAC/DC 31 ATD 48 180.00<br />
9.6-96s 110-127VAC 31 ATD 110 180.00<br />
76.8-768s<br />
220-240VAC 31 ATD 220 180.00<br />
Time-range setting<br />
ON<br />
2<br />
1<br />
ON<br />
2<br />
1<br />
ON<br />
2<br />
1<br />
ON<br />
2<br />
1<br />
0.3-3s 1.2-12s 9.6-96s 76.8-768s<br />
General characteristics<br />
– True off delay. Does not require continuous power<br />
source.<br />
– Single voltage, multiscale<br />
– One relay output with 1 SPDT contact<br />
– Delay time adjustable on front using potentiometer<br />
– Time scale setting using dip switches<br />
– LED indication for power on and relay state<br />
– 22.5mm (0.9in) wide housing suitable for mounting<br />
on 35mm DIN rail (IEC/EN 60715)<br />
– Screw fixing adapter CE106.<br />
Certifications and compliance<br />
UL listed for USA and Canada, File E93601.<br />
Compliant with standards: IEC/EN 61812-1.<br />
31 ATD<br />
Operational diagram<br />
See page W-10.<br />
Off delay after<br />
external contact<br />
opening.<br />
Multiscale<br />
Time of Control Catalog number Price<br />
scale range power<br />
[V]<br />
$ each<br />
With auxiliary power supply.<br />
0.3-3s<br />
24VAC/DC 31 AT1DP 24❶ 115.00<br />
1.2-12s 48VAC/DC 31 AT1DP 48❶ 115.00<br />
9.6-96s 110-127VAC 31 AT1DP 110 115.00<br />
76.8-768s<br />
220-240VAC 31 AT1DP 220 115.00<br />
General characteristics<br />
– Off delay after external contact opening, single<br />
voltage, multiscale<br />
– One relay output with 1 SPDT contact<br />
– Delay time adjustable on front using potentiometer<br />
– Time range setting using dip switches<br />
– LED indication for power on and relay state<br />
– 22.5mm wide housing suitable for mounting on<br />
35mm DIN rail (IEC/EN 60715)<br />
– Screw fixing adapter CE106.<br />
31 AT1DP<br />
❶ With DC supply, connect (–) polarity to terminal A2.<br />
Time-range setting<br />
ON<br />
2<br />
1<br />
0.3-3s<br />
ON<br />
2<br />
1<br />
1.2-12s<br />
ON<br />
2<br />
1<br />
9.6-96s<br />
ON<br />
2<br />
1<br />
76.8-768s<br />
Certifications and compliance<br />
UL listed for USA and Canada, File E93601.<br />
Compliant with standards: IEC/EN 61812-1.<br />
Operational diagram<br />
See page W-10.<br />
Multifunction.<br />
Multiscale.<br />
Multivoltage.<br />
1 double-throw<br />
contact<br />
31 BTPM1<br />
Time of Control Catalog number Price<br />
scale range power<br />
[V]<br />
$ each<br />
0.3-3s 24VAC/DC 31 BTPM1 220 118.00<br />
1.2-12s 110-127VAC<br />
9.6-96s 220-240VAC<br />
76.8-768s 24-48-60V 31 BTPM1 60❷ 118.00<br />
0.3-3min AC/DC<br />
1.2-12min<br />
9.6-96min<br />
76.8-768min<br />
❷ Available on request.<br />
Time-range setting<br />
ON<br />
8<br />
7<br />
6<br />
5<br />
4<br />
3<br />
2<br />
1<br />
ON<br />
8<br />
7<br />
6<br />
5<br />
4<br />
3<br />
2<br />
1<br />
ON<br />
8<br />
7<br />
6<br />
5<br />
4<br />
3<br />
2<br />
1<br />
ON<br />
8<br />
7<br />
6<br />
5<br />
4<br />
3<br />
2<br />
1<br />
ON<br />
8<br />
7<br />
6<br />
5<br />
4<br />
3<br />
2<br />
1<br />
ON<br />
8<br />
7<br />
6<br />
5<br />
4<br />
3<br />
2<br />
1<br />
ON<br />
8<br />
7<br />
6<br />
5<br />
4<br />
3<br />
2<br />
1<br />
ON<br />
8<br />
7<br />
6<br />
5<br />
4<br />
3<br />
2<br />
1<br />
0.3-3s 1.2-12s 9.6-96s 76.8-768s 0.3-3min 1.2-12min 9.6-96min 76.8-768min<br />
General characteristics<br />
– Multifunction, multivoltage, multiscale<br />
– One relay output with 1 SPDT contact<br />
– Delay time adjustable on front<br />
– Selectable functions: Delay on operate with relay<br />
de-energized. Pulsing on relay energizing. Delay on or<br />
off after on opening of external contact. Pulsing.<br />
Pulsing on opening of external contact<br />
– Time scale and functions selected by dip switches<br />
– LED indication for power on and relay state<br />
– Time relay resetting possible by using an external<br />
contact connected at R1-R2 terminals; 5ms resetting<br />
time<br />
– 22.5mm (0.9in) wide housing suitable for mounting<br />
on 35mm DIN rail (IEC/EN 60715)<br />
– Screw fixing adapter CE107.<br />
Certifications and compliance<br />
UL listed for USA and Canada, File E93601.<br />
Compliant with standards: IEC/EN 61812-1.<br />
Operational diagram<br />
See page W-10.<br />
10<br />
Accessories<br />
pages 10-7<br />
Dimensions<br />
page D-29<br />
Wiring diagrams<br />
page W-10<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com<br />
Technical characteristics<br />
pages TC-36 and 37
10-6 Timers<br />
electric<br />
DIN rail mount timers<br />
Multifunction.<br />
Multiscale.<br />
Multivoltage.<br />
2 independent<br />
double-throw<br />
contacts<br />
31 BTPM<br />
Time of Control Catalog number Price<br />
scale range power<br />
[V]<br />
$ each<br />
0.3-3s 24VAC/DC 31 BTPM 220 132.00<br />
1.2-12s 110-127VAC<br />
9.6-96s 220-240VAC<br />
76.8-768s 24-48-60V 31 BTPM 60❶ 132.00<br />
0.3-3min AC/DC<br />
1.2-12min<br />
9.6-96min<br />
76.8-768min<br />
❶ Available on request.<br />
Time-range setting<br />
ON<br />
8<br />
7<br />
6<br />
5<br />
4<br />
3<br />
2<br />
1<br />
ON<br />
8<br />
7<br />
6<br />
5<br />
4<br />
3<br />
2<br />
1<br />
ON<br />
8<br />
7<br />
6<br />
5<br />
4<br />
3<br />
2<br />
1<br />
ON<br />
8<br />
7<br />
6<br />
5<br />
4<br />
3<br />
2<br />
1<br />
ON<br />
8<br />
7<br />
6<br />
5<br />
4<br />
3<br />
2<br />
1<br />
ON<br />
8<br />
7<br />
6<br />
5<br />
4<br />
3<br />
2<br />
1<br />
ON<br />
8<br />
7<br />
6<br />
5<br />
4<br />
3<br />
2<br />
1<br />
ON<br />
8<br />
7<br />
6<br />
5<br />
4<br />
3<br />
2<br />
1<br />
0.3-3s 1.2-12s 9.6-96s 76.8-768s 0.3-3min 1.2-12min 9.6-96min 76.8-768min<br />
General characteristics<br />
– Multifunction, multivoltage, multiscale<br />
– Two output relays, each with 1 SPDT contact,<br />
programmable by dip switches<br />
– Delay time adjustable on front using potentiometer<br />
– Selectable functions: Delay on operate with relay<br />
de-energized. Delay on relay energizing. Delay on or<br />
off after opening of external contact. Pulsing<br />
beginning with pause. Pulsing beginning with work.<br />
Pulsing after opening of external contact beginning<br />
with pause. Pulsing after opening of external contact<br />
beginning with work.<br />
Possibility, selectable by dip switches, to program an<br />
output relay with instantaneous function (21-22-24<br />
output)<br />
– Time scale and functions selected by dip switches<br />
– LED indication for power on and relay state<br />
– Time relay resetting possible by using an external<br />
contact connected at R1-R2 terminals; 5ms resetting<br />
time<br />
– 22.5mm (0.9in) wide housing suitable for mounting<br />
on 35mm DIN rail (IEC/EN 60715)<br />
– Screw fixing adapter CE107.<br />
Certifications and compliance<br />
UL listed for USA and Canada, file E93601.<br />
Compliant with standards: IEC/EN 61812-1.<br />
Operational diagram<br />
See page W-11.<br />
10<br />
Programmable<br />
asymmetrical<br />
recycle timer<br />
Time of Control Catalog number Price<br />
scale range power<br />
[V]<br />
$ each<br />
0.3-3s 24VAC/DC 31 DRPL 220 176.00<br />
0.6-6s 110-127VAC<br />
1.2-12s 220-240VAC<br />
3-30s<br />
6-60s<br />
48-60VAC/DC 31 DRPL 60❷ 176.00<br />
12-120s<br />
0.3-3min<br />
0.6-6min<br />
1.2-12min<br />
3-30min<br />
6-60min<br />
12-120min<br />
❷ Available on request.<br />
General characteristics<br />
– Programmable asymmetrical recycle timers,<br />
multivoltage, multiscale<br />
– Two relay outputs, each with SPDT contact<br />
– Pause and work time adjustable on front using<br />
potentiometers<br />
– Time scale selected by independent dip switches<br />
– LED indication for power on and relay state<br />
– Cycle can begin with work interval instead of pause<br />
(jumper on S1-S2 terminals)<br />
– 45mm (1.8in) wide housing suitable for mounting on<br />
35mm DIN rail (IEC/EN 60715)<br />
– Screw fixing adapter CE106.<br />
Certifications and compliance<br />
UL listed for USA and Canada, file E93601.<br />
Compliant with standards: IEC 61812-1.<br />
31 DRPL<br />
Time-range setting<br />
ON<br />
1<br />
2<br />
3<br />
4<br />
5<br />
6<br />
7<br />
8<br />
ON<br />
1<br />
2<br />
3<br />
4<br />
5<br />
6<br />
7<br />
8<br />
ON<br />
1<br />
2<br />
3<br />
4<br />
5<br />
6<br />
7<br />
8<br />
ON<br />
1<br />
2<br />
3<br />
4<br />
5<br />
6<br />
7<br />
8<br />
ON<br />
1<br />
2<br />
3<br />
4<br />
5<br />
6<br />
7<br />
8<br />
ON<br />
1<br />
2<br />
3<br />
4<br />
5<br />
6<br />
7<br />
8<br />
0.3-3s 0.6-6s 1.2-12s 3-30s 6-60s 12-120s<br />
Functional diagram<br />
See page W-10.<br />
ON<br />
1<br />
2<br />
3<br />
4<br />
5<br />
6<br />
7<br />
8<br />
ON<br />
1<br />
2<br />
3<br />
4<br />
5<br />
6<br />
7<br />
8<br />
ON<br />
1<br />
2<br />
3<br />
4<br />
5<br />
6<br />
7<br />
8<br />
ON<br />
1<br />
2<br />
3<br />
4<br />
5<br />
6<br />
7<br />
8<br />
ON<br />
1<br />
2<br />
3<br />
4<br />
5<br />
6<br />
7<br />
8<br />
ON<br />
1<br />
2<br />
3<br />
4<br />
5<br />
6<br />
7<br />
8<br />
0.3-3min 0.6-6min 1.2-12min 3-30min 6-60min 12-120min<br />
Accessories<br />
pages 10-7<br />
Dimensions<br />
page D-29<br />
Wiring diagrams<br />
page W-11<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com<br />
Technical characteristics<br />
page TC-37
electric<br />
Timers<br />
DIN rail mount and accessories<br />
10-7<br />
Timer for starters<br />
31 BT2N<br />
Time of Control Catalog number Price<br />
scale scale power<br />
[V]<br />
$ each<br />
0.6-6s 31 BT2N 6S 48 106.00<br />
1.2-12s 24VAC/DC 31 BT2N 12S 48 106.00<br />
3-30s 48VAC/DC 31 BT2N 30S 48 106.00<br />
6-60s 31 BT2N 60S 48 106.00<br />
0.6-6s 31 BT2N 6S 110 106.00<br />
1.2-12s 24VAC/DC 31 BT2N 12S 110 106.00<br />
3-30s 110-127VAC 31 BT2N 30S 110 106.00<br />
6-60s 31 BT2N 60S 110 106.00<br />
0.6-6s 31 BT2N 6S 220 106.00<br />
1.2-12s 24VAC/DC 31 BT2N 12S 220 106.00<br />
3-30s 220-240VAC 31 BT2N 30S 220 106.00<br />
6-60s 31 BT2N 60S 220 106.00<br />
0.6-6s 31 BT2N 6S 380 106.00<br />
1.2-12s 24VAC/DC 31 BT2N 12S 380 106.00<br />
3-30s 380-415VAC 31 BT2N 30S 380 106.00<br />
6-60s 31 BT2N 60S 380 106.00<br />
General characteristics<br />
– Dual voltage, for starters (wye-delta, impedance,<br />
autotransformer, etc.) of induction motors, 2 separate<br />
timing<br />
– Two output relays, each with 1 SPDT contact<br />
– Starting time and transition time (20-300ms)<br />
adjustable on front using potentiometers<br />
– LED indication for power on and relay state<br />
– 22.5mm (0.9in) wide housing suitable for mounting<br />
on 35mm DIN rail (IEC/EN 60715)<br />
– Screw fixing adapter CE107<br />
– Timing starts immediately as soon as voltage is<br />
applied to time relay; upon expiry of the interval<br />
(starting time), the two output relays are energized in<br />
sequence.<br />
The first one disables the starting contactor, which<br />
opens; the second one, after the time interval which<br />
can be adjusted between 20 and 300ms (transition),<br />
enables the second contactor to close.<br />
If the supply is removed before the set time expires,<br />
the time already elapsed is reset.<br />
Certifications and compliance<br />
UL listed for USA and Canada, file E93601.<br />
Compliant with standards: IEC/EN 61812-1.<br />
Operational diagram<br />
See page W-11.<br />
0.6-6s 31 BT2N 6S 440 106.00<br />
1.2-12s 24VAC/DC 31 BT2N 12S 440 106.00<br />
3-30s 415-440VAC 31 BT2N 30S 440 106.00<br />
6-60s 31 BT2N 60S 440 106.00<br />
Accessories for<br />
DIN rail mount<br />
timers<br />
Description Catalog number Price<br />
$ each<br />
Screw fixing adapter 31 CE106 3.00<br />
for timers: AT1 - AT1C - AT1P -<br />
AT1CP - ATD - AT1DP - DRPL<br />
Screw fixing adapter 31 CE107 3.00<br />
for timers: BTPM1 - BTPM -<br />
BT2N<br />
10<br />
Dimensions<br />
page D-29<br />
Wiring diagrams<br />
page W-11<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com<br />
Technical characteristics<br />
page TC-37
10-8 Timers<br />
electric<br />
Plug-in timers<br />
10<br />
Plug-in and<br />
flush-mount timers<br />
31 L48TP<br />
31 L48TPB<br />
31 L48M<br />
Time of Control Catalog number Price<br />
scale range power<br />
$ each<br />
Time relay, on delay.<br />
Multiscale and multivoltage, 8-pin.<br />
0.1-780s<br />
24VAC/DC<br />
31 L48TP S 240 72.00<br />
1.8s-780min<br />
110VAC<br />
220-240VAC 31 L48TP M 240 72.00<br />
Time range setting.<br />
1<br />
0<br />
AB AB AB AB<br />
1<br />
1<br />
1<br />
0<br />
0<br />
0<br />
L48TP S 0.3-3s 1.2-12s 10-100s 78-780s<br />
L48TP M 18s-3min 72s-12min 10s-100min 78s-780min<br />
Time of Control Catalog number Price<br />
scale range power<br />
$ each<br />
Time relay, on delay.<br />
Multiscale and single voltage, 8-pin.<br />
24VAC/DC 31 L48TPB M24 79.00<br />
0.05s-10min 110VAC 31 L48TPB M110 79.00<br />
220-240VAC 31 L48TPB M240 79.00<br />
Time range setting.<br />
1<br />
0<br />
0.05-1s 0.1-10s 0.6-1min 6s-10min<br />
Time of Control Catalog number Price<br />
scale range power<br />
$ each<br />
Time relay, multifunction, multivoltage and multiscale, 11-pin.<br />
0.05s-10min 24-240V 31 L48M M 240 82.00<br />
0.6s-10h AC/DC 31 L48M H 240 82.00<br />
Time range setting.<br />
1<br />
0<br />
AB AB AB AB<br />
1<br />
1<br />
1<br />
0<br />
0<br />
0<br />
AB AB AB AB<br />
1<br />
1<br />
1<br />
0<br />
0<br />
0<br />
L48M M 0.05-1s 0.1-10s 0.6s-1min 6s-10min<br />
L48M H 0.05-1min 0.1-10min 0.6min-1h 1min-10h<br />
General characteristics<br />
L48TP TIMER<br />
– On delay, multivoltage, multiscale<br />
– One relay output with 1 SPDT contact<br />
– Delay time adjustable on front by rotary knob<br />
– Time scale selected by dip switches:<br />
for L48TP S: 0.3-3s, 1.2-12s, 10-100s or 78-780s<br />
for L48TP M: 18s-3min, 72s-12min, 10-100min or<br />
78-780min<br />
– LED indication for power on and relay state<br />
– Use with 8-pin socket, see page 10-9<br />
– Flush mount bracket, see page 10-9<br />
– Degree of protection: IP40 on front; IP20 at rear.<br />
L48TPB TIMER<br />
– On delay, single voltage, multiscale<br />
– Two relay outputs, each with 1 SPDT contact,<br />
adjustable as both delayed at energization or<br />
1 delayed and 1 instantaneous at energization<br />
– Delay time adjustable on front by royary knob<br />
– Time scale selected by dip switches:<br />
0.05-1s, 0.1-10s, 0.6s-1min, 6s-10min<br />
– LED indication for power on and relay state<br />
– Use with 8-pin socket, see page 10-9<br />
– Flush mount bracket, see page 10-9<br />
– Degree of protection: IP40 on front; IP20 at rear.<br />
L48M TIMER<br />
– Multifunction, multivoltage and multiscale<br />
– 2 DPDT output contacts<br />
– Delay time adjustable on front<br />
– Selectable functions: Delay on operate when relay<br />
de-energized. Delay on operate when relay energized.<br />
Pulsing beginning with pause. Pulsing beginning with<br />
work. Time relay resetting is possible on closing of<br />
external contact (R) connected to terminals 7-6.<br />
Possibility of stopping the time relay saving the<br />
elapsed time on closing of external contact (M)<br />
connected to terminals 7-5 and then restarting time<br />
on opening it. See diagrams on page W-9.<br />
– Time scale and functions selected by dip switches:<br />
for L48M M: 0.05-1s, 0.1-10s, 0.6s-1min, 6s-10min<br />
for L48M H: 0.05s-1min, 0.1s-10min, 0.6m-1h,<br />
1min-10h<br />
– LED indication for power on and relay state<br />
– Use with 11-pin socket, see page 10-9<br />
– Flush mount bracket, see page 10-9<br />
– Degree of protection: IP40 on front; IP20 at rear.<br />
Certifications and compliance<br />
UL Recognized for USA and Canada, file E172189.<br />
Compliant to standards: IEC/EN 61812-1.<br />
Housing size 48x48mm = 1.9x1.9in<br />
Operational diagrams<br />
See page W-12.<br />
Accessories<br />
page 10-9<br />
Dimensions<br />
page D-29<br />
Wiring diagrams<br />
page W-12<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com<br />
Technical characteristics<br />
page TC-37
electric<br />
Timers<br />
Accessories<br />
10-9<br />
Accessories for<br />
plug-in and<br />
flush-mount timers<br />
Description Catalog number Price<br />
$ each<br />
8-pin socket for screw 31 S8 9.00<br />
fixing or on 35mm DIN<br />
rail (IEC/EN 60715).<br />
Screw terminals.<br />
8-pin loose socket. 31 L48 P8 12.00<br />
Screw terminals.<br />
11-pin socket for screw 31 S11 10.50<br />
fixing or on 35mm DIN<br />
rail (IEC/EN 60715).<br />
Screw terminals.<br />
11-pin loose socket. 31 L48 P11 14.00<br />
Screw terminals.<br />
Flush mount bracket. 31 L48AP 5.00<br />
Certifications<br />
Sockets: CSA certified, file LR 26716.<br />
UL recognized, file E113714.<br />
10<br />
Dimensions<br />
page D-29<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com
PAGE 11-2 AND 3<br />
MODULAR VOLTAGE RELAYS<br />
• For single phase system<br />
• For three phase system without neutral<br />
• Powered by monitored voltage<br />
• Programmable rated voltage value to monitor<br />
• Delayed tripping.<br />
PAGE 11-4<br />
MODULAR CURRENT RELAYS<br />
• For single phase system<br />
• Undercurrent, overcurrent and combination<br />
• Auxiliary power supply<br />
• Automatic or manual resetting<br />
• Selectable functions.<br />
OTHER MODULAR RELAYS<br />
• Frequency control<br />
• Phase shift control<br />
• Selectable operating mode.<br />
PAGE 11-5<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com
11<br />
PROTECTION RELAYS<br />
Modular version<br />
Minimum and maximum voltage<br />
monitoring relays for single and<br />
three phase systems, without<br />
neutral<br />
Minimum and maximum current<br />
monitoring relays with dual<br />
thresholds<br />
Frequency monitoring relay<br />
Phase shift relay.<br />
PLANET -DIN<br />
Modular voltage control<br />
SEC. PAGE<br />
For single-phase systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11- 2<br />
For three-phase systems, without neutral . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11- 2<br />
Modular current control<br />
For single phase systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11- 4<br />
Modular frequency control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11- 5<br />
Modular phase shift control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11- 5<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com
11-2 Protection relays<br />
electric<br />
Modular voltage monitoring relays<br />
Voltage monitoring<br />
for single-phase<br />
systems<br />
PMV55<br />
Rated voltage Catalog number Price<br />
to be controlled Ue<br />
[V] 50/60Hz<br />
$ each<br />
Single-phase system.<br />
Minimum and maximum voltage control.<br />
208-240VAC PMV55 A240 200.00<br />
380-440VAC PMV55 A440 200.00<br />
General characteristics<br />
– Voltage monitoring relay for high and low voltage<br />
conditions of single-phase systems; powered by the<br />
monitored voltage<br />
– 4 programmable rated voltages:<br />
• For PMV55 A240: 208-220-230-240VAC<br />
• For PMV55 A440: 380-400-415-440VAC<br />
– Excellent tripping accuracy<br />
– TRMS measures (True Root Mean Square value)<br />
– 1 relay output with 1 SPDT contact<br />
– Modular housing, 1.38in (35mm) wide<br />
– Degree of protection: IP40 on front (only when<br />
mounted in housing or electric board with IP40);<br />
IP20 on terminals.<br />
ADJUSTMENTS:<br />
“V max” Tripping threshold for high voltage<br />
105-115% Ue<br />
“V min” Tripping threshold for low voltage<br />
80-95% Ue<br />
“Delay” for each Tripping time 0.1-20 seconds<br />
“Reset delay” Resetting time 0.1-20 seconds.<br />
Certifications and compliance<br />
UL listed for USA and Canada, File E 93601.<br />
Compliant with standards: IEC/EN 60255-6,<br />
IEC/EN 61000-6-2, IEC/EN 61000-6-3.<br />
Operational diagram<br />
See page W-12.<br />
Voltage monitoring<br />
for three-phase<br />
systems without<br />
neutral<br />
Rated voltage Catalog number Price<br />
to be controlled Ue<br />
phase to phase<br />
[V] 50/60Hz<br />
$ each<br />
Three-phase system, without neutral.<br />
Phase loss and incorrect phase sequence. Delayed tripping.<br />
17.5mm/0.69in module.<br />
208-440VAC PMV10 A440 125.00<br />
35mm/1.4in module.<br />
100-240VAC PMV20 A240 140.00<br />
208-575VAC PMV20 A575 140.00<br />
380-600VAC PMV20 A600 140.00<br />
General characteristics<br />
– Voltage monitoring relay for phase loss and incorrect<br />
phase sequence of three-phase systems, without neutral;<br />
powered by the monitored voltage. Delayed tripping<br />
– Detection of phase loss if one of the voltages is
electric<br />
Protection relays<br />
Modular voltage monitoring relays<br />
11-3<br />
PMV40<br />
PMV50<br />
Rated voltage Catalog number Price<br />
to be controlled Ue<br />
phase to phase<br />
[V] 50/60Hz<br />
$ each<br />
Three-phase system, without neutral.<br />
Phase loss, incorrect phase sequence and high asymmetry<br />
control. Delayed tripping.<br />
208-240VAC PMV40 A240 200.00<br />
380-575VAC PMV40 A575 200.00<br />
600VAC PMV40 A600 200.00<br />
Three-phase system, without neutral.<br />
Phase loss, incorrect phase sequence, minimum and<br />
maximum voltage control. Delayed tripping.<br />
208-240VAC PMV50 A240 260.00<br />
380-575VAC PMV50 A575 260.00<br />
600VAC PMV50 A600 260.00<br />
Three-phase system, without neutral.<br />
Phase loss, incorrect phase sequence, minimum voltage and<br />
high asymmetry control. Delayed tripping.<br />
208-240VAC PMV60 A240 300.00<br />
380-575VAC PMV60 A575 300.00<br />
600VAC PMV60 A600 300.00<br />
Three-phase system, without neutral.<br />
Phase loss, incorrect phase sequence, minimum and maximum<br />
voltage and high asymmetry control. Delayed tripping.<br />
208-240VAC PMV70 A240 325.00<br />
380-575VAC PMV70 A575 325.00<br />
600VAC PMV70 A600 325.00<br />
General characteristics<br />
PMV40 is voltage monitoring relay for phase loss,<br />
incorrect phase sequence and high asymmetry<br />
conditions of three-phase systems, without neutral.<br />
PMV50 is a voltage monitoring relay for phase loss,<br />
incorrect phase sequence, low and high voltage<br />
conditions of three-phase systems, without neutral.<br />
PMV60 is a voltage monitoring relay for phase loss,<br />
incorrect phase sequence, low voltage and high<br />
asymmetry conditions of three-phase systems, without<br />
neutral.<br />
PMV70 is a voltage monitoring relay for phase loss,<br />
incorrect phase sequence, low and high voltage and high<br />
asymmetry conditions of three-phase systems, without<br />
neutral.<br />
Features common to these 4 types:<br />
– Powered by the monitored voltage<br />
– Delayed tripping<br />
– 4 programmable rated voltages for PMV... A240:<br />
208-220-230-240VAC<br />
– 8 programmable rated voltages for PMV... A575:<br />
380-400-415-440-460-480-525-575VAC<br />
– Excellent tripping accuracy<br />
– TRMS measures (True Root Mean Square value)<br />
– Control of phase-to-phase voltages<br />
– Phase loss detection if one of the voltages is
11-4 Protection relays<br />
electric<br />
Modular current monitoring relays<br />
Current monitoring<br />
for single-phase<br />
systems<br />
PMA20<br />
Rated Auxiliary Catalog number Price<br />
current control<br />
Ie<br />
power<br />
[A] [V] $ each<br />
Single-phase system.<br />
AC/DC undercurrent control. Auxiliary AC/DC supply.<br />
Automatic or manual resetting.<br />
0.02-1-5-16 24-240V PMA20 ❶<br />
multiscale AC/DC<br />
❶ Coming in 2007, contact Sales & Technical Support for availability and pricing.<br />
General characteristics<br />
– Current monitoring for low current conditions of singlephase<br />
systems. AC/DC multivoltage auxiliary supply.<br />
Automatic or manual resetting<br />
– Direct connection or by current transformer (CT)<br />
– Excellent tripping accuracy<br />
– TRMS current measures (True Root Mean Square value)<br />
– Resetting and inhibition input<br />
– 1 relay output with 1 SPDT contact<br />
– Modular housing, 2.07in (52.5mm) wide<br />
– Degree of protection: IP40 on front (only when<br />
mounted in housing or electric board with IP40);<br />
IP20 on terminals.<br />
ADJUSTMENTS:<br />
“I min” Tripping threshold for low current<br />
5-100% end scale<br />
“Reset Hysteresis” Resetting hysteresis 5-30%<br />
“Trip delay” Tripping time 0.1-20 seconds<br />
“Inhibition time” Inhibition time 0.1-20 seconds.<br />
Certifications and compliance<br />
UL listing for USA and Canada, pending completion.<br />
Compliant with standards: IEC/EN 60255-6,<br />
IEC/EN 61000-6-2, IEC/EN 61000-6-3.<br />
Operational diagram<br />
See page W-13.<br />
Overcurrent relay<br />
PMA21<br />
Rated Auxiliary Catalog number Price<br />
current control<br />
Ie<br />
power<br />
[A] [V] $ each<br />
Single-phase system.<br />
AC/DC undercurrent control. Auxiliary AC/DC supply.<br />
Automatic or manual resetting.<br />
0.02-1-5-16 24-240V PMA21 ❶<br />
multiscale AC/DC<br />
❶ Coming in 2007, contact Sales & Technical Support for availability and pricing.<br />
General characteristics<br />
– Current monitoring for high current conditions of<br />
single-phase systems. AC/DC multivoltage auxiliary<br />
supply. Automatic or manual resetting<br />
– Direct connection or by current transformer (CT)<br />
– Excellent tripping accuracy<br />
– TRMS current measures (True Root Mean Square value)<br />
– Resetting and inhibition input<br />
– 1 relay output with 1 SPDT contact<br />
– Modular housing, 2.07in (52.5mm) wide<br />
– Degree of protection: IP40 on front (only when<br />
mounted in housing or electric board with IP40);<br />
IP20 on terminals.<br />
ADJUSTMENTS:<br />
“I max” Tripping threshold for high current<br />
5-100% end scale<br />
“Reset hysteresis” Resetting hysteresis 5-30%<br />
“Trip delay” Tripping time 0.1-20 seconds<br />
“Inhibition time Inhibition time 0.1-20 seconds.<br />
Certifications and compliance<br />
UL listing for USA and Canada, pending completion.<br />
Compliant with standards: IEC/EN 60255-6,<br />
IEC/EN 61000-6-2, IEC/EN 61000-6-3.<br />
Operational diagram<br />
See page W-13.<br />
11<br />
Combination<br />
under/overcurrent<br />
relay<br />
PMA30<br />
Rated Auxiliary Catalog number Price<br />
current control<br />
Ie<br />
power<br />
[A] [V] $ each<br />
Single-phase system.<br />
AC/DC under/overcurrent control.<br />
Auxiliary AC/DC supply. Automatic or manual resetting.<br />
0.02-1-5-16 24-240V PMA30 ❶<br />
multiscale AC/DC<br />
❶ Coming in 2007, contact Sales & Technical Support for availability and pricing.<br />
General characteristics<br />
– Current monitoring for high/low current conditions of<br />
single-phase systems. AC/DC multivoltage auxiliary<br />
supply. Automatic or manual resetting<br />
– 4 selectable tripping functions:<br />
• Low current<br />
• High current<br />
• Low current with reset pulsing<br />
• High current with reset pulsing<br />
– Direct connection or by current transformer (CT)<br />
– Excellent tripping accuracy<br />
– TRMS current measures (True Root Mean Square value)<br />
– Resetting and inhibition input<br />
– 1 relay output with 1 SPDT contact<br />
– Modular housing, 2.07in (52.5mm) wide<br />
– Degree of protection: IP40 on front (only when<br />
mounted in housing or electric board with IP40);<br />
IP20 on terminals.<br />
ADJUSTMENTS:<br />
“Set point”<br />
Tripping threshold for low current<br />
5-100% end scale<br />
“Reset Hysteresis” Resetting hysteresis 5-30%<br />
“Trip delay”<br />
“Inhibition time”<br />
“Reset delay”<br />
“Mode”<br />
Tripping time 0.1-20 seconds<br />
Inhibition time 0.1-20 seconds<br />
Time delay for resetting<br />
0.1-20 seconds<br />
A to H operating mode.<br />
Certifications and compliance<br />
UL listing for USA and Canada, pending completion.<br />
Compliant with standards: IEC/EN 60255-6,<br />
IEC/EN 61000-6-2, IEC/EN 61000-6-3.<br />
Operational diagram<br />
See page W-14.<br />
Dimensions<br />
page D-30<br />
Wiring diagrams<br />
pages W-13 and 14<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com<br />
Technical characteristics<br />
page TC-39
electric<br />
Frequency<br />
monitoring<br />
PMF20<br />
Protection relays<br />
Modular voltage monitoring relays<br />
Control Catalog number Price<br />
power<br />
[V] 50/60Hz<br />
$ each<br />
Minimum and/or maximum frequency control.<br />
220-240VAC PMF20 A240 360.00<br />
380-415VAC PMF20 A415 360.00<br />
11-5<br />
General characteristics<br />
– Frequency monitoring for high and low frequency<br />
conditions; powered by the monitored voltage<br />
– Rated frequency choice: 50Hz or 60Hz<br />
– 4 operating modes<br />
• Tripping threshold for high frequency in not function<br />
• Tripping threshold for high frequency<br />
• Tripping threshold for low frequency<br />
• Tripping threshold for low and high<br />
– Tripping threshold for low or high frequency<br />
– Excellent tripping accuracy<br />
– 1 relay output with 1 SPDT contact<br />
– Modular housing, 1.38in (35mm) wide<br />
– Degree of protection: IP40 on front (only when<br />
mounted in housing or electric board with IP40);<br />
IP20 on terminals.<br />
ADJUSTMENTS:<br />
frequency<br />
“Delay” Tripping time 0.1-20 seconds<br />
“Hz max” Tripping threshold for high frequency<br />
+1 to +10%<br />
“Hz min” Tripping threshold for low frequency<br />
-1 to -10%<br />
“Reset delay” Resetting time 0.1-20seconds.<br />
Certifications and compliance<br />
UL listed for USA and Canada, File E 93601.<br />
Compliant with standards: IEC/EN 60255-6,<br />
IEC/EN 61000-6-2, IEC/EN 61000-6-3.<br />
Operational diagram<br />
See page W-14.<br />
Phase shift<br />
monitoring<br />
PMA40<br />
PMA50<br />
Rated<br />
current<br />
Ie<br />
Auxiliary<br />
control<br />
power<br />
Catalog number Price General characteristics<br />
PMA40 is a phase control relay for pump protection<br />
against dry running. Suitable for single and three-phase<br />
[A] [V] $ each systems. Auxiliary AC control power.<br />
PMA50 is a phase shift monitoring relay for single or<br />
Single and three-phase systems.<br />
three-phase systems. Auxiliary AC control power.<br />
For pump protection. AC control power.<br />
Automatic or manual resetting.<br />
0.02-1-5-16 220-240VAC PMA40 A240 ❶<br />
Programmable operating modes:<br />
multiscale 380-415VAC PMA40 A415 ❶<br />
For PMA40:<br />
– Single phase control<br />
Single and three-phase systems. Phase shift control.<br />
– Three phase control<br />
AC control power. Automatic or manual resetting.<br />
For PMA50<br />
0.02-1-5-16 220-240VAC PMA50 A240 ❶<br />
– Minimum control for three phases<br />
multiscale 380-415VAC PMA50 A415 ❶<br />
– Maximum control for three phases<br />
– Minimum control for single phase<br />
❶ Coming in 2007, contact Sales & Technical Support for availability and pricing.<br />
– Maximum control for single phase<br />
11<br />
Features common to both types:<br />
– Direct connection or by external CT<br />
– Selector for single or three-phase system<br />
– Resetting for inhibition input<br />
– Excellent tripping accuracy<br />
– 1 relay output with 1 SPDT contact<br />
– Modular housing, 2.07in (52.5mm) wide<br />
– Degree of protection: IP40 on front (only when<br />
mounted in housing or electric board with IP40);<br />
IP20 on terminals.<br />
ADJUSTMENTS FOR PMA40<br />
“Set point cosϕ” Tripping threshold for minimum c<br />
osϕ 0-1<br />
“Trip delay Sec” Tripping time 0.1-20 seconds<br />
ADJUSTMENTS FOR PMA50:<br />
“Set point cosϕ“<br />
Tripping threshold for minimum<br />
cosϕ 0-1<br />
“Hysteresis” Resetting hysteresis 5-30%<br />
“Trip delay”<br />
“Inhibition”<br />
“Reset delay”<br />
Tripping time 0.1-20 seconds<br />
Inhibition time 0.1-20 seconds<br />
Resetting time 0.1-20 seconds.<br />
Certifications and compliance<br />
UL listing for USA and Canada pending.<br />
Compliant with standards: IEC/EN 60255-6,<br />
IEC/EN 61000-6-2, IEC/EN 61000-6-3.<br />
Operational diagram<br />
See page W-14.<br />
Dimensions<br />
page D-30<br />
Wiring diagrams<br />
page W-14<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com<br />
Technical characteristics<br />
page TC-39
LEVEL MONITORING RELAYS<br />
• Single or dual voltage<br />
• Emptying or filling functions<br />
• Multifunction<br />
• Automatic resetting.<br />
PAGE 12-2<br />
ELECTRODES<br />
• Single pole<br />
• Three pole.<br />
PAGE 12-3<br />
PAGE 12-5<br />
MODULAR START-UP PRIORITY CHANGE RELAYS<br />
• Alternate starting control of two motors.<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com
12<br />
LIQUID LEVEL CONTROL RELAYS<br />
Level monitoring for electrically<br />
conductive liquids<br />
Modular version<br />
Adjustable 2.5-200kΩ sensitivity<br />
Startup priority change relays.<br />
PLANET -DIN<br />
Level monitoring relays<br />
SEC. PAGE<br />
For conductive liquids . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12- 2<br />
Electrodes and electrode holders . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12- 4<br />
Start-up priority change relays<br />
Priority change relays . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12- 5<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com
12-2 Liquid level control relays<br />
electric<br />
Single and multi voltage types<br />
Modular<br />
single-voltage relay<br />
LVM20<br />
Control Type of Catalog number Price<br />
power output<br />
contacts<br />
[V] 50/60Hz<br />
$ each<br />
Automatic resetting.<br />
24VAC SPDT LVM20 A024 108.00<br />
110-127VAC SPDT LVM20 A127 108.00<br />
220-240VAC SPDT LVM20 A240 108.00<br />
380-415VAC SPDT LVM20 A415 108.00<br />
Operational characteristics<br />
– 3 sensing electrodes, MIN, MAX and COM<br />
– 2.5-50kOhm sensitivity<br />
– 1 relay output with SPDT contact<br />
– Double insulation between supply, electrodes and<br />
output relay circuit<br />
– Fixed probe signal delay:
Modular<br />
single-voltage<br />
multifunction relay<br />
LVM40<br />
electric<br />
Liquid level control relays<br />
Single voltage type<br />
Control Type of Catalog number Price<br />
power output<br />
contacts<br />
[V] 50/60Hz<br />
$ each<br />
Multiple functions.<br />
Automatic resetting.<br />
24VAC SPDT +1 N/O LVM40 A024 265.00<br />
110-127VAC SPDT +1 N/O LVM40 A127 265.00<br />
220-240VAC SPDT +1 N/O LVM40 A240 265.00<br />
380-415VAC SPDT +1 N/O LVM40 A415 265.00<br />
12-3<br />
Operational characteristics<br />
– 5 sensing electrodes, MIN1, MAX1, MIN2, MAX2 and<br />
COM<br />
– 2.5-200kOhm sensitivity<br />
– Sensitivity adjustment: 25-50-100-200kOhm<br />
– Separate sensitivity adjustment of MAX electrodes for<br />
foam detection<br />
– Insensitivity to stray electrode-cable capacitance<br />
– Programming selector for 5 different functions:<br />
• Standard emptying and filling with alarms<br />
• Emptying and filling with SUPER-MIN and/or<br />
SUPER-MAX relay<br />
• Emptying and filling with priority start-up change<br />
control<br />
• Emptying and filling with priority start-up change<br />
pump and standby pump control<br />
• Well draining and tank filling with dry-running alarm<br />
relay<br />
– 2 relay outputs, one with SPDT contact and one with<br />
normally open (N/O) contact<br />
– Double insulation between each supply, electrodes and<br />
output relay circuits<br />
– Adjustable probe signal delay: 1-10 seconds<br />
– Adjustable pump start delay: 0-30 minutes<br />
– Green LED indicator for power on<br />
– Red LED indicators for output relay and electrode state<br />
– Modular housing, 2.07in (52.5mm) wide<br />
– Degree of protection:IP40 on front (only when<br />
mounted in housing or electric board with IP40);<br />
IP20 on terminals.<br />
Certifications and compliance<br />
UL listed for USA and Canada, File E93601.<br />
Compliant with standards: IEC/EN 60255-6.<br />
Electrodes and Electrode holders<br />
Use electrodes and electrode holders type:<br />
SN1/PS31/PS3S/SCM/CGL or similar type. See page 12-4.<br />
12<br />
Dimensions<br />
page D-30<br />
Wiring diagrams<br />
page W-16<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com
Liquid level control relays<br />
12-4<br />
electric<br />
Electrodes and<br />
electrode holders<br />
11 SN1<br />
31 SCM...<br />
Level electrodes - Electrode holders -<br />
Rod probes for conductve liquids<br />
Rod probe Rod probe Catalog number Price<br />
length included<br />
[in / mm]<br />
$ each<br />
Single-pole electrodes.<br />
For wells and storage tanks.<br />
0.39 / 10 Yes 11 SN1 25.00<br />
For boilers and autoclaves.<br />
1.57 / 40 Yes 31 SCM 04 61.00<br />
19.7 / 500 Yes 31 SCM 50 106.00<br />
39.4 / 1000 Yes 31 SCM 100 111.00<br />
For boilers and autoclaves.<br />
15.75 / 300 Yes 31 CGL125 3 126.00<br />
19.7 / 500 Yes 31 CGL125 5 136.00<br />
27.6 / 700 Yes 31 CGL125 7 152.00<br />
39.4 / 1000 Yes 31 CGL125 10 176.00<br />
Three-pole electrodes.<br />
For small containers.<br />
15.75 / 300 Yes 31 PS31 96.00<br />
Electrode holder for 3 rod probes.<br />
For general use.<br />
31 PS3S No 31 PS3S 122.00<br />
General characteristics<br />
SN1 SINGLE-POLE ELECTRODE<br />
Used for level control in wells and storage tanks.<br />
It comprises an AISI 313 stainless steel probe, a plastic<br />
(PPOX) holder and a cable gland.<br />
A sealing ring and the tightening of the cable gland<br />
prevent liquid from entering the wire terminal connector<br />
which causes oxidation.<br />
The external wire diameter must be 0.1-0.24in<br />
(2.5-6mm) to warrant perfect sealing of the PG7 gland<br />
Terminal connection: Screw<br />
Maximum operating temperature: +140°F/+60°C<br />
Application: Tanks and deep wells.<br />
SCM ELECTRODE<br />
Used for level control on boilers, autoclaves and in<br />
general where pressure (10 bar maximum) and high<br />
temperature (212°F/100°C maximum) are present.<br />
It includes an AISI 303 stainless steel probe embedded<br />
in an alumina oxide body and a 3/8” GAS threaded metal<br />
support holder.<br />
Terminal connection: Screw.<br />
Application: Tanks, pressurized tanks and boilers.<br />
CGL125 ELECTRODE<br />
Used for level control on boilers and autoclaves and in<br />
general wherever pressure is up to 10 bar maximum.<br />
It includes an AISI 302 probe and 3/8” threaded<br />
terminal.<br />
Maximum operating temperature: 356°F/+180°C<br />
Threaded rod and nut.<br />
Application: Tanks, pressurized tanks and boilers.<br />
31 CGL125...<br />
31 PS31<br />
PS31 Electrode<br />
A small electrode holder, complete with three AISI 304<br />
stainless steel probes.<br />
Particularly suited to small containers whenever<br />
pressure is up to 2 bar maximum.<br />
1/2” GAS threaded coupling.<br />
Faston termination for wire connection; relative lugs<br />
standard supplied.<br />
Maximum operating temperature: +158°F/+70°C<br />
Application: Tanks and automatic dispensers.<br />
PS3S ELECTRODE HOLDER<br />
A thermoset resin electrode holder to be used with three<br />
probes (rod probes to be purchased separately) comes<br />
complete with terminal cover.<br />
1/2” GAS threaded coupling.<br />
Maximum operating temperature: +212°F/+100°C.<br />
Wire connection: Screw<br />
Application: Tanks.<br />
12<br />
31 PS3S<br />
Rod probes<br />
Rod probe Catalog number Price<br />
length<br />
[in / mm]<br />
$ each<br />
Extensions for SCM electrode.<br />
18.1 / 460 31 ASTA 460 MM4 30.00<br />
37.8 / 960 31 ASTA 960 MM4 35.00<br />
Coupler unit for ASTA...MM4 probe extension.<br />
- 31 RE213 6.00<br />
For PS3S electrode holder.<br />
18.1 / 460 31 ASTA 460 MM6 37.00<br />
37.8 / 960 31 ASTA 960 MM6 43.00<br />
General characteristics<br />
Stainless steel AISI 304 probes with 4M or 6M threaded<br />
extremity suitable as extensions for SCM electrode or as<br />
rod probe for PS3S a holder.<br />
Dimensions<br />
page D-30<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com
electric<br />
Modular start-up<br />
priority change<br />
relays<br />
LVM P05<br />
LVM P10<br />
Liquid level control relays<br />
Start-up priority change relays<br />
Control Type of Catalog number Price<br />
power output<br />
contacts<br />
[V]<br />
$ each<br />
2 outputs. AC/DC supply voltage.<br />
24-48VDC 2 N/O LVM P05 116.00<br />
24-240VAC<br />
2 outputs. AC supply voltage.<br />
24VAC 2 N/O LVM P10 A024 133.00<br />
110-127VAC 2 N/O LVM P10 A127 133.00<br />
220-240VAC 2 N/O LVM P10 A240 133.00<br />
390-415VAC 2 N/O LVM P10 A415 133.00<br />
12-5<br />
General characteristics<br />
The relays are designed to balance the operating time, and<br />
hence the wear of pumps, compressors, generators, when<br />
two units – primary and stand-by – are installed.<br />
The LVM P05 type is multivoltage and has simple<br />
operation and installation. It alternates the starting of two<br />
motors at each power up. The flashing rate of the relay<br />
LED identifies which of the two relay outputs is energized.<br />
The LVM P10 is programmable and is normally used with<br />
float switches, level controls, pressure switches, etc.,<br />
equipped with dry contacts. It can be connected to either<br />
2 or 3-wire start-stop motor control, to exclude control<br />
contact chattering when used with float or pressure<br />
switches.<br />
It has 4 inputs for motor control, 2 of which for starting<br />
and 2 for stopping, each protected against over-voltage<br />
conditions. Usage can be either as priority change of 2<br />
motors or the control for the simultaneous operation of 2<br />
motors, by activating the stand-by motor 4 seconds after<br />
the first motor starting, to avoid current peaks and<br />
subsequent mains voltage drop.<br />
Operational characteristics<br />
– Operating limit: 0.85-1.1 Ue<br />
– Maximum power consumption: 16VA for LVM P05;<br />
3.5VA for LVM P10<br />
– Maximum power dissipation: 0.9W for LVM P05;<br />
1.8W for LVM P10<br />
– Connection: permanent<br />
– 2 output relays each with 1 normally open (N/O)<br />
contact<br />
– Rated contact voltage: 250VAC<br />
– Rated switching voltage: 400VAC<br />
– UL designation: B300 (AC1 8A 250V)<br />
– Green LED indicator for power on<br />
– Red LED indicators for output relay state<br />
– Modular housing: 0.71in (18mm) wide for LVM P05;<br />
2.07in (52.5mm) wide for LVM P10<br />
– Degree of protection: IP40 on front (only when<br />
mounted in housing or electric board with IP40);<br />
IP20 on terminals.<br />
Certifications and compliance<br />
UL listed for USA and Canada, File E93601.<br />
Compliant with standards: IEC/EN 60255-6.<br />
12<br />
Dimensions<br />
page D-30<br />
Wiring diagrams<br />
page W-17<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com
PAGE 13-2<br />
SINGLE PHASE DIGITAL INSTRUMENTS<br />
• Modular and flush-mount types<br />
• Single function voltmeter<br />
• Single function ammeter<br />
• Single function voltmeter or ammeter<br />
• Single function frequency meter<br />
• Single function cosphi meter<br />
• Available without or complete with programmable<br />
relay output for protection activation.<br />
THREE PHASE DIGITAL INSTRUMENTS<br />
• Modular and flush-mount types<br />
• Single function voltmeter<br />
• Single function ammeter<br />
• Multifunction: voltage, current, watt readouts<br />
• Available without or complete with programmable<br />
relay output for protection activation.<br />
PAGE 13-6<br />
DIGITAL MULTIMETERS<br />
DMK 2...- DMK 5... (47 electric parameters)<br />
• Basic version: DMK 20 - DMK 50<br />
• Version with energy meters: DMK 21 - DMK 51<br />
• Version with energy meters and RS485 port:<br />
DMK 22 - DMK 52<br />
• Version for use with generating sets: DMK 25 - DMK 55.<br />
DMK 3... - DMK40 - DMK 6... (251 electric parameters)<br />
• Basic version: DMK 30 - DMK 60<br />
• Version with 2 programmable outputs:<br />
DMK 31 - DMK 61<br />
• Versions with 2 programmable outputs and RS485<br />
port: DMK 32 - DMK 62<br />
• Version with data-logger, RS232 and RS485 ports:<br />
DMK 40.<br />
CURRENT TRANSFORMERS<br />
• Primary: 40-1000A<br />
• Secondary: 5A.<br />
PAGE 13-9<br />
MULTIMETER FUNCTIONS<br />
SUMMARY<br />
96x96mm housing ➨<br />
Modular housing ➨<br />
Usage in medium and high voltage systems<br />
INSTANTANEOUS MEASUREMENTS:<br />
Instantaneous measurements:<br />
Voltage (phase-to-phase, phase, system)<br />
Current ➊<br />
Apparent power (phase, system)<br />
Active-reactive import power (phase, system)<br />
Frequency (input voltage)<br />
Power factor (phase)<br />
Cosϕ<br />
Active-reactive export power (phase, system),<br />
system integral apparent power<br />
Battery supply voltage<br />
Voltage imbalance<br />
Current imbalance<br />
HARMONIC ANALYSIS<br />
Even-odd, 2° to 22° orders, of phase voltages and currents<br />
Total and residual distortion<br />
METER/COUNTER<br />
Imported active-reactive energy power<br />
Exported active-reactive energy power<br />
Total and partial operating hours<br />
STORAGE OF INSTANTANEOUS MINIMUM AND MAXIMUM VALUES<br />
Voltage and current (phase)<br />
Import active-reactive power (system)<br />
Export active-reactive power (system)<br />
Average/maximum integral active-apparent power<br />
DIGITAL OUTPUTS<br />
1 relay, rated B300/5A 250V AC1<br />
1 static, rated 55mA 60VAC/DC AC1<br />
SERIAL INTERFACE<br />
RS485 port<br />
RS232 port<br />
➊ Maximum integral phase, system and imbalance current values obtainable with DMK SW remote control software only.<br />
❷ Available with use of DMK SW remote control software only. ...<br />
❸ Serial ports cannot be used simultaneously.<br />
DMK 25 DMK 26 DMK 20 DMK 21 DMK 22 DMK 30 DMK 31 DMK 32 DMK 40<br />
DMK 50 DMK 51 DMK 52 DMK 60 DMK 61 DMK 62<br />
❷<br />
❸<br />
❸<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com
13<br />
DIGITAL METERING INSTRUMENTS AND CURRENT TRANSFORMERS<br />
Metering instruments for voltage,<br />
current, frequency, power factor<br />
and watt readouts, also including<br />
a variety of programmable<br />
protections features available on<br />
version with relay output<br />
Single and multi function metering<br />
devices<br />
Monitor and measure of 47, 51 and<br />
251 electric parameters<br />
Single and three-phase<br />
connection<br />
Ideal for co-generation energy<br />
systems, stand-by generating sets<br />
or on-board machine tools<br />
High measurement accuracy<br />
Totally programmable digital<br />
outputs<br />
RS485 serial port used with<br />
Modbus ® RTU or ASCII protocols.<br />
PLANET -LOGIC<br />
Digital metering instruments<br />
SEC. PAGE<br />
Single-phase modular instruments, without or complete with output relay . . . . . 13- 2<br />
Three-phase modular instruments, without or complete with output relay . . . . . . 13- 4<br />
Digital multimeters<br />
51 measurements - flush-mount three-phase type . . . . . . . . . . . . . . . . . . . . . . . . . . 13- 6<br />
47 measurements - flush-mount and modular types . . . . . . . . . . . . . . . . . . . . . . . . 13- 7<br />
251 measurements - flush-mount and modular types . . . . . . . . . . . . . . . . . . . . . . . 13- 8<br />
Currrent transformers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13- 9<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com
13-2<br />
Digital metering instruments<br />
and current transformers<br />
electric<br />
13<br />
For single phase<br />
systems<br />
Modular type<br />
DMK 80<br />
DMK 81<br />
DMK 80 R1<br />
DMK 81 R1<br />
DMK 82 DMK 82<br />
DMK 83<br />
DMK 84<br />
DMK 83 R1<br />
DMK 84 R1<br />
Description Catalog Price<br />
number<br />
$ each<br />
Digital control, without programmable relay output.<br />
Voltmeter - 3 viewed DMK 80 A127 171.00<br />
measurements; 15-660VAC<br />
readout and 1.00-500.00 PT ratio<br />
programming ranges<br />
Ammeter - 3 viewed DMK 81 A127 171.00<br />
measurements; 0.05-5.75A<br />
readout 5-10,000 CT primary<br />
programming ranges<br />
Voltmeter or ammeter - 3 viewed DMK 82 A127❶ 189.00<br />
measurements; ranges:<br />
15-660VAC or 0.05-5.75A<br />
readout and 1.00-500.00 PT ratio<br />
or OFF/5-10,000 CT primary<br />
programming ranges<br />
Frequency meter - 3 viewed DMK 83 A127 237.00<br />
measurements; 15-65Hz<br />
readout range, ±1 digit accuracy;<br />
15-660VAC voltage input range<br />
Cosphi meter - 2 viewed DMK 84 A127 237.00<br />
measurements; cosϕ readout<br />
error: ±0.5° ±1 digit, measured<br />
in 4 quadrants.<br />
Digital control, complete with programmable relay output.<br />
Voltmeter - 3 viewed DMK 80 R1A127 186.00<br />
measurements; 15-660VAC<br />
readout and 1.00-500.00 PT ratio<br />
programming ranges<br />
Ammeter - 3 viewed DMK 81 R1 A127 186.00<br />
measurements; 0.05-5.75A<br />
readout 5-10,000 CT primary<br />
programming ranges<br />
Frequency meter - 3 viewed DMK 83 R1 A127 251.00<br />
measurements; 15-65Hz readout<br />
range, ±1 digit accuracy;<br />
15-660VAC voltage input range<br />
Cosphi meter - 2 viewed DMK 84 R1 A127 251.00<br />
measurements; cosϕ readout<br />
error: ±0.5° ±1 digit, measured<br />
in 4 quadrants.<br />
❶ The DMK 82 can operate as a voltmeter or ammeter. It is duly equipped with<br />
two front plates (V and A) which must be fitted by the user depending on<br />
which instrument is required and on the wiring scheme used.<br />
General characteristics<br />
The modular digital metering instruments of the DMK<br />
series provide excellent stability of readouts due to a very<br />
high sampling rate.<br />
The measurements in TRMS provide for a correct<br />
operation, even in presence of voltage and current<br />
conditions with high harmonic content. All models are<br />
able to store and display maximum (HIGH) and minimum<br />
(LOW) values of the readouts.<br />
The DMK...R1 types also come equipped with one relay<br />
output, configurable with a number of protection and<br />
configurable functions, as stated below.<br />
They can be used directly in low voltage (
electric<br />
Digital metering instruments<br />
and current transformers<br />
13-3<br />
For single phase<br />
systems<br />
Flush-mount type<br />
DMK 00<br />
Description Catalog Price<br />
number❶<br />
$ each<br />
Digital control, without programmable relay output.<br />
Voltmeter - 3 viewed DMK 00 A127 171.00<br />
measurements; 15-660VAC<br />
readout and 1.00-500.00 PT ratio<br />
programming ranges<br />
Ammeter - 3 viewed DMK 01 A127 171.00<br />
measurements; 0.05-5.75A<br />
readout 5-10,000 CT primary<br />
programming ranges<br />
Voltmeter or ammeter - 3 viewed DMK 02 A127❷ 189.00<br />
measurements; ranges:<br />
15-660VAC or 0.05-5.75A readout<br />
and 1.00-500.00 PT ratio or<br />
OFF/5-10,000 CT primary<br />
programming ranges<br />
Frequency meter - 3 viewed DMK 03 A127 237.00<br />
measurements; 45-66Hz<br />
readout range, ±1 digit accuracy;<br />
15-660VAC voltage input range<br />
Cosphi meter - 2 viewed DMK 04 A127 237.00<br />
measurements; cosϕ readout<br />
error: ±0.5° ±1 digit, measured<br />
in 4 quadrants.<br />
Digital control, complete with programmable relay output.<br />
Voltmeter - 3 viewed DMK 00 R1 A127 186.00<br />
measurements; 15-660VAC<br />
readout and 1.00-500.00 PT ratio<br />
programming ranges<br />
Ammeter - 3 viewed DMK 01 R1 A127 186.00<br />
measurements; 0.05-5.75A<br />
readout 5-10,000 CT primary<br />
programming ranges<br />
Frequency meter - 3 viewed DMK 03 R1 A127 251.00<br />
measurements; 45-66Hz readout<br />
range, ±1 digit accuracy;<br />
15-660VAC voltage input range<br />
Cosphi meter - 2 viewed DMK 04 R1 A127 251.00<br />
measurements; cosϕ readout<br />
error: ±0.5° ±1 digit, measured<br />
in 4 quadrants.<br />
❶ Coming in 2007, contact Sales & Technical Support for availability.<br />
❷ The DMK 02 can operate as a voltmeter or ammeter. It is duly equipped with<br />
two front plates (V and A) which must be fitted by the user depending on<br />
which instrument is required and on the wiring scheme used.<br />
General characteristics<br />
The flush-mount digital metering instruments of the DMK<br />
series provide excellent stability of readouts due to a very<br />
high sampling rate.<br />
The measurements in TRMS provide for a correct<br />
operation, even in presence of voltage and current<br />
conditions with high harmonic content. All models are<br />
able to store and display maximum (HIGH) and minimum<br />
(LOW) values of the readouts.<br />
The DMK...R1 types also come equipped with one relay<br />
output, configurable with a number of protection and<br />
configurable functions, as stated below.<br />
They can be used directly in low voltage (
13-4<br />
Digital metering instruments<br />
and current transformers<br />
electric<br />
13<br />
For three phase<br />
systems<br />
Modular type<br />
DMK 70<br />
DMK 71<br />
DMK 75<br />
DMK 70 R1<br />
DMK 71 R1<br />
DMK 75 R1<br />
Description Catalog Price<br />
number<br />
$ each<br />
Digital control, without programmable relay output.<br />
Voltmeter - 18 viewed DMK 70 A127 200.00<br />
measurements; 15-660VAC L-L<br />
(10-382V L-N)<br />
readout and 1.00-500.00 PT ratio<br />
programming ranges<br />
Ammeter - 9 viewed DMK 71 A127 200.00<br />
measurements; 0.05-5.75A<br />
readout 5-10,000 CT primary<br />
programming ranges<br />
Combined voltmeter, ammeter DMK 75 A127 314.00<br />
and wattmeter - 39 viewed<br />
measurements; 35-660VAC L-L<br />
(20-382V L-N)<br />
and 0.05-5.75A readout,<br />
1.00-500.00 PT ratio and<br />
5-10,000 CT primary<br />
programming ranges<br />
Digital control, complete with programmable relay output.<br />
Voltmeter - 3 viewed DMK 70 R1A127 214.00<br />
measurements; 15-660VAC L-L<br />
(10-382V L-N)<br />
readout and 1.00-500.00 PT ratio<br />
programming ranges<br />
Ammeter - 3 viewed DMK 71 R1 A127 214.00<br />
measurements; 0.05-5.75A<br />
readout 5-10,000 CT primary<br />
programming ranges<br />
Combined voltmeter, ammeter DMK 75 R1 A127 328.00<br />
and wattmeter - 39 viewed<br />
measurements; 35-660VAC L-L<br />
(20-382V L-N)<br />
and 0.05-5.75A readout,<br />
1.00-500.00 PT ratio and<br />
5-10,000 CT primary<br />
programming ranges<br />
❶ Independent time delay, configurable for each of the mentioned functions.<br />
General characteristics<br />
The modular digital metering instruments of the DMK<br />
series provide excellent stability of readouts due to a very<br />
high sampling rate.<br />
The measurements in TRMS provide for a correct<br />
operation, even in presence of voltage and current<br />
conditions with high harmonic content. All models are<br />
able to store and display maximum (HIGH) and minimum<br />
(LOW) values of the readouts.<br />
The DMK...R1 types also come equipped with one relay<br />
output, configurable with a number of protection and<br />
configurable functions, as stated below.<br />
They can be used directly in low voltage (
electric<br />
Digital metering instruments<br />
and current transformers<br />
13-5<br />
For three phase<br />
systems<br />
Flush-mount type<br />
DMK 15<br />
Description Catalog Price<br />
number❶<br />
$ each<br />
Digital control, without programmable relay output.<br />
Voltmeter - 18 viewed DMK 10 A127 200.00<br />
measurements; 15-660VAC L-L<br />
(10-382V L-N)<br />
readout and 1.00-500.00 PT ratio<br />
programming ranges<br />
Ammeter - 9 viewed DMK 11 A127 200.00<br />
measurements; 0.05-5.75A<br />
readout 5-10,000 CT primary<br />
programming ranges<br />
Combined voltmeter, ammeter DMK 15 A127 314.00<br />
and wattmeter - 39 viewed<br />
measurements; 15-660VAC L-L<br />
(20-382V L-N)<br />
and 0.05-5.75A readout,<br />
1.00-500.00 PT ratio and<br />
5-10,000 CT primary<br />
programming ranges<br />
Digital control, complete with programmable relay output.<br />
Voltmeter - 3 viewed DMK 10 R1 A127 214.00<br />
measurements; 15-660VAC L-L<br />
(10-382V L-N)<br />
readout and 1.00-500.00 PT ratio<br />
programming ranges<br />
Ammeter - 3 viewed DMK 11 R1 A127 214.00<br />
measurements; 0.05-5.75A<br />
readout 5-10,000 CT primary<br />
programming ranges<br />
Combined voltmeter, ammeter DMK 15 R1 A127 328.00<br />
and wattmeter - 39 viewed<br />
measurements; 15-660VAC L-L<br />
(20-382V L-N)<br />
and 0.05-5.75A readout,<br />
1.00-500.00 PT ratio and<br />
5-10,000 CT primary<br />
programming ranges<br />
❶ Coming in 2007, contact Sales & Technical Support for availability.<br />
❷ Independent time delay, configurable for each of the mentioned functions.<br />
General characteristics<br />
The flush-mount digital metering instruments of the DMK<br />
series provide excellent stability of readouts due to a very<br />
high sampling rate.<br />
The measurements in TRMS provide for a correct<br />
operation, even in presence of voltage and current<br />
conditions with high harmonic content. All models are<br />
able to store and display maximum (HIGH) and minimum<br />
(LOW) values of the readouts.<br />
The DMK...R1 types also come equipped with one relay<br />
output, configurable with a number of protection and<br />
configurable functions, as stated below.<br />
They can be used directly in low voltage (
13<br />
13-6<br />
Digital multimeter<br />
51 measurements<br />
DMK 16<br />
Digital metering instruments<br />
and current transformers<br />
Description Catalog Price<br />
number<br />
$ each<br />
Multimeter - 51 viewed DMK 16 A127 ❶ 378.00<br />
measurements; 110-127VAC,<br />
7-segment 4-digit display.<br />
❶ Coming in 2007; contact Sales & Technical support for availability.<br />
electric<br />
General characteristics<br />
This flush-mount digital multimeter provides excellent<br />
stability and viewing of readouts even in presence of<br />
critical operating conditions, such as voltages and<br />
currents with high harmonic content and variable<br />
frequency. It is a cost-effective solution to replace<br />
traditional analog instruments.<br />
It is capable of storing and displaying 23 different<br />
maximum (HIGH) and minimum (LOW) measurements,<br />
can be used directly in low voltage (
electric<br />
Digital metering instruments<br />
and current transformers<br />
13-7<br />
Digital multimeters<br />
47 measurements<br />
DMK 50<br />
DMK 20<br />
Characteristics Catalog Price<br />
number<br />
$ each<br />
Modular housing.<br />
Basic version, 110-127VAC DMK 50 120 447.00<br />
Version with energy meters DMK 51 120 494.00<br />
included, 110-127VAC<br />
Version with energy meters and DMK 52 120 626.00<br />
RS485 port included, 110-127VAC<br />
Flush-mount housing.<br />
Basic version, 110-127VAC DMK 20 120 447.00<br />
Version with energy meters DMK 21 120 494.00<br />
included, 110-127VAC<br />
Version with energy meters DMK 22 120 626.00<br />
and RS485 port included,<br />
110-127VAC<br />
Version for generating set duty, DMK 25 525.00<br />
12-24VDC<br />
Version for generating set duty DMK 26 598.00<br />
with maximum current demand,<br />
voltage and current imbalance,<br />
12-24VDC<br />
Accessories.<br />
Remote supervision software for DMK SW 971.00<br />
PC ↔ DMK 22/52, with<br />
Modbus ® -RTU and ASCII<br />
protocols, complete with 51 C4<br />
connecting cable<br />
RS232/RS485 converter drive, 4 PX1 115 661.00<br />
opto-isolated, 110-120VAC<br />
PC ↔ PX1 drive connecting cable, 51 C4 65.00<br />
6ft (1.8m) long<br />
IP54 front protection cover for 31 PA96X96 34.00<br />
DMK20/21/22/25/26 types<br />
General characteristics<br />
DMK 2... and DMK 5... multimeters monitor and view<br />
reliable readings of electric parameters, even in presence<br />
of critical operating conditions, such as voltages and<br />
currents with high harmonic content and variable<br />
frequency. The total and partial hour counter feature<br />
provides an interesting feature for electric panels of<br />
emergency generating sets.<br />
The diversified and accurate measure give the multimeters<br />
valuable technical and cost effective advantages respect to<br />
traditional analog instrumentation.<br />
The digital multimeters DMK 2... and DMK 5... view 47<br />
electric parameters:<br />
– Voltage: phase, line and system values<br />
– Battery voltage: 9-38VDC for DMK 25 and DMK 26 only<br />
– Current: phase values<br />
– Power: apparent phase, active and reactive values<br />
– P.F.: power factor per phase<br />
– Frequency of measured voltage value<br />
– HIGH/LOW: instantaneous minimum and maximum<br />
values of each phase voltage and current, total active<br />
power (ΣW), total reactive power (Σvar) and total<br />
apparent power (ΣVA) values<br />
– Total hours: non-volatile clearable log for DMK 20,<br />
DMK 25, DMK 26 and DMK 50 only<br />
– Partial hours: non-volatile configurable log for DMK 20,<br />
DMK 25, DMK 26 and DMK 50 only.<br />
Operational characteristics<br />
For DMK20 and DMK50:<br />
– Auxiliary power: 110-127VAC standard; 208-240VAC<br />
on request<br />
– Operating limits: 90-152VAC for standard supply<br />
For DMK 21, DMK 22, DMK51 and DMK 52<br />
– Auxiliary supply: 110-127VAC standard; 208-240VAC<br />
on request<br />
– Operating limits: 94-140VAC for standard supply<br />
For DMK 25 and DMK26:<br />
– Auxiliary supply: 12-24VDC standard<br />
– Operating limits: 9-32VDC<br />
For all types:<br />
– Voltage measure range: 60-830VAC L-L<br />
– Current measure range: 0.05-6A<br />
– Frequency range: 45-65Hz<br />
– CT ratio programming range: 1.0-2,000<br />
– Accuracy<br />
• Voltage/current readouts: 0.5 ±0.25% ful scale ±1 digit<br />
• Energy class 2 (IEC/EN 61036; IEC/EN 61268)<br />
– Non-volatile total and partial hour counter with<br />
separate clearing; used as maintenance interval with<br />
display alarm in DMK 20, DMK 25, DMK 26 and<br />
DMK 50 only<br />
– Partial hour counter used as maintenance interval with<br />
display alarm<br />
– HIGH and LOW value functions to read and log<br />
instantaneous voltage, current and power values<br />
– Delayed automatic resetting of default measures<br />
– Averaging function to slow down repetitive fluctuations<br />
to obtain more stable readouts<br />
– Current connection in ARON configuration via 2 current<br />
transformers (CTs) only<br />
– Single, two, three phase with or without neutral and<br />
balanced three-phase connection<br />
– TRMS measurements up to 22° harmonic order<br />
– Housing:<br />
flush mount 3.8x3.8in (96x96mm) for DMK 2...<br />
modular for DMK 5...<br />
– Degree of protection: IP54 on front for DMK 2...<br />
IP41 on front for DMK 5...<br />
IP 20 at rear.<br />
13<br />
Certifications and compliance<br />
UL listed for USA and Canada, File E93601.<br />
Compliant with standards: IEC/EN 61010-1,<br />
IEC/EN 61000-6-3, IEC/EN 61000-6-2, CISPR11/EN 55011.<br />
Dimensions<br />
page D-31<br />
Wiring diagrams<br />
page W-18<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com<br />
Technical characteristics<br />
pages TC-44 and 45
13-8 Digital metering instruments<br />
electric<br />
and current transformers<br />
13<br />
Digital multimeters<br />
251 measurements<br />
DMK 60<br />
DMK 30<br />
DMK 40<br />
Characteristics Catalog Price<br />
number<br />
$ each<br />
Modular housing.<br />
Basic version DMK 60 881.00<br />
Version with 2 programmable DMK 61 1066.00<br />
outputs of which 1 relay and<br />
1 static type<br />
Version with RS485 port and 2 DMK 62 1235.00<br />
programmable outputs of which<br />
1 relay and 1 static type<br />
Flush-mount housing.<br />
Basic version DMK 30 881.00<br />
Version with 2 programmable DMK 31 1066.00<br />
outputs of which 1 relay and<br />
1 static type<br />
Version with RS485 port and 2 DMK 32 1235.00<br />
programmable outputs of which<br />
1 relay and 1 static type<br />
Version with data-logger, RS232 DMK 40 2503.00<br />
and RS485 opto-isolated ports<br />
Accessories.<br />
Remote supervision software for DMK SW 971.00<br />
PC ↔ DMK 32/62, with<br />
Modbus ® -RTU and ASCII<br />
protocols, complete with 51 C4<br />
connecting cable<br />
Data-logger software for DMK SW 10 1100.00<br />
PC ↔ DMK 40 complete with<br />
51 C2 connecting cable and<br />
remote supervision software<br />
DMK SW and 51 C4 connecting<br />
cable<br />
RS232/RS485 converter drive, 4 PX1 115 661.00<br />
opto-isolated, 110-120VAC<br />
PC ↔ DMK 40 connecting cable, 51 C2 60.00<br />
6ft (1.8m) long<br />
PC ↔ PX1 drive connecting cable, 51 C4 65.00<br />
6ft (1.8m) long<br />
DMK 40 ↔ analog modem 51 C5 69.00<br />
connecting cable, 6ft (1.8m) long<br />
Analog modem ↔ 4 PX1 51 C9 83.00<br />
converter drive connecting cable,<br />
6ft (1.8m) long<br />
IP54 front protection cover for 31 PA96X96 34.00<br />
DMK 30/31/32/40<br />
General characteristics<br />
DMK 3.. and DMK 6... multimeters comprise excellent<br />
features, superior to devices of the same category<br />
currently on the marketplace. Distorted waveform<br />
conditions, such as very disturbed electric lines having<br />
voltage and currents with high harmonic content and<br />
variable frequency, do not influence the high accuracy<br />
DMK multimeter readouts because of rigorous design in<br />
addition to the use of the latest generation of<br />
microprocessor technology. Measurement of the phase<br />
angle (cosϕ) in addition to power factor, harmonics<br />
analysis and<br />
HIGH-LOW-MAX functions are just a few of those which<br />
are difficult to find on higher category equipment.<br />
The DMK 40 version includes a reliable data-logger<br />
system, extremely easy to use.<br />
DMK 3..., DMK 40 and DMK 6... digital multimeter can<br />
display more than 251 measurements; a few of these are<br />
listed below.<br />
– Voltage: phase, line and system values<br />
– Current: phase and system values<br />
– Power: active, reactive, apparent phase and total values<br />
– Energy: import, export, inductive and capacitive values<br />
– P.F.: power factor per phase<br />
– cosϕ: angle displacement, i.e. power factor related to<br />
the harmonic fundamental only<br />
– Frequency of measured voltage value<br />
– Harmonics (HARM.): residual and total harmonic<br />
content for each harmonic order up to the 22° per<br />
phase, both for voltage and current values<br />
– HIGH / LOW: readings of maximum / minimum values<br />
of phase voltage and current and ΣW, Σvar and ΣVA<br />
power<br />
– Maximum (MAX): readings of maximum current and<br />
total active power values, both calculated on<br />
programmable integration time.<br />
The technical features of the DMK 40 data-logger are:<br />
– 2Mb non-volatile memory for data logging<br />
– Real Time Clock (RTC) with replaceable back-up<br />
lithium battery<br />
– Sampling time, 1s to 24h configurable<br />
– Number of sampling measures, 1 to 32 configurable at<br />
a time<br />
– Communication protocols: Modbus ® -RTU and ASCII<br />
– Data logging of one electric parameter in continuous<br />
format or with begin and end by programmable<br />
thresholds<br />
– Suspension of data acquisition at full memory or<br />
refreshing of oldest data.<br />
Operational characteristics<br />
– Auxiliary power: 100-240VAC; 110-250VDC<br />
– Operating range: 85-265VAC; 93.5-300VDC<br />
– Voltage measure range: 20-830VAC L-L in one model<br />
– Current measure range: 0.02-6A<br />
– HIGH and LOW value functions to detect and log<br />
instantaneous voltage, current and power values<br />
– Averaging function to slow down repetitive<br />
fluctuations to obtain more stable readouts<br />
– Current connection in ARON configuration via 2<br />
current transformers only<br />
– Single, three phase with or without neutral and balanced<br />
three-phase connection via 1 current transformer only<br />
– Usage with potential transformers for voltages >830VAC<br />
– Operating frequency: 45-65Hz<br />
– TRMS measurements up to 22° harmonic order,<br />
class 1 accuracy<br />
– Power factor and cosϕ measure<br />
– Voltage and current harmonic analysis per phase up to<br />
22° harmonic order<br />
– <strong>Electric</strong> meters of active energy (import-export)<br />
– <strong>Electric</strong> meters of reactive energy (inductive-capacitive)<br />
– Housing: flush mount 3.8x3.8in (96x96mm) for<br />
DMK 3...and DMK 40; modular for DMK 6...<br />
– Degree of protection:<br />
IP54 on front for DMK 3... and DMK 40<br />
IP41 on front for DMK 6...<br />
IP 20 at rear.<br />
Certifications and compliance<br />
UL listed for USA and Canada, File E93601.<br />
Compliant with standards: IEC/EN 61010-1,<br />
IEC/EN 61000-6-2, CISPR11/EN 55011.<br />
Dimensions<br />
page D-31<br />
Wiring diagrams<br />
page W-19<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com<br />
Technical characteristics<br />
page TC-45
electric<br />
Current<br />
transformers<br />
DM1T<br />
DM2T<br />
Digital metering instruments<br />
and current transformers<br />
Primary Burden Catalog Price<br />
Current Class 0.5 Class 1 number<br />
[/5A] [VA] [VA] $ each<br />
For Ø0.87in / 22mm wire.<br />
40 - 1 DM1T 0040 34.00<br />
50 - 1 DM1T 0050 34.00<br />
60 - 1 DMIT 0060 34.00<br />
80 1.5 3 DM1T 0080 34.00<br />
100 1.5 3 DM1T 0100 34.00<br />
150 1.5 3 DM1T 0150 34.00<br />
For Ø0.91in / 23mm wire.<br />
For 1.2X0.9in / 30X10mm, 1X0.6in / 25X15mm,<br />
0.8X0.6in / 20X15mm busbars.<br />
60 - 1 DM2T 0060 36.00<br />
80 - 1 DM2T 0080 36.00<br />
100 - 1 DM2T 0100 36.00<br />
150 - 1 DM2T 0150 36.00<br />
200 1.5 3 DM2T 0200 36.00<br />
250 1.5 3 DM2T 0250 36.00<br />
300 1.5 3 DM2T 0300 39.00<br />
400 1.5 4 DM2T 0400 39.00<br />
For 1.6X0.9in / 40X10mm, 1.2X0.8in / 30X20mm,<br />
1X1in / 25X25mm busbars.<br />
200 2 4 DM3T 0200 51.00<br />
250 2.5 5 DM3T 0250 51.00<br />
300 4 6 DM3T 0300 63.00<br />
400 5 6 DM3T 0400 63.00<br />
500 6 10 DM3T 0500 70.00<br />
600 6 12 DM3T 0600 70.00<br />
800 8 15 DM3T 0800 89.00<br />
1000 10 20 DM3T 1000 89.00<br />
S1 S2<br />
K L<br />
P1-K<br />
S1 S2<br />
K L<br />
13-9<br />
General characteristics<br />
The DM...T series current transformers (CT) are installed<br />
in electric systems to reduce the line current to a<br />
secondary value of 5A, which is compatible with current<br />
inputs of digital multimeters or protection relays.<br />
These are without primary winding and are used for high<br />
primary current values from 40A upward.<br />
Suitable for screw fixing or mounting on 35mm DIN rail<br />
(IEC/EN 60715), using the standard-supplied kit.<br />
The number of loops of the primary cable does not<br />
modify the accuracy but converts the primary current<br />
value proportional to secondary current.<br />
S1 S2<br />
K L<br />
P1-K<br />
300 / 5A standard<br />
1 loop = 300 / 5A<br />
300 / 5A<br />
2 loops = 150 / 5A<br />
300 / 5A<br />
3 loops = 100 / 5A<br />
DM3T<br />
P1-K<br />
Operational characteristics<br />
– Operating frequency: 40-60Hz<br />
– Secondary output current: 5A<br />
– Overload withstand: 1.2 In<br />
– Rated dynamic current Idyn: 2.5 rated Ith current for<br />
1 second<br />
– Insulation (dry type): class E<br />
– Ambient conditions:<br />
• Operating temperature: -4...+122°F (-20 ... +50°C)<br />
• Storage temperature: -40...+176°F (-40 ... +80°C)<br />
• Relative humidity: 90%, no condensation<br />
• Degree of protection: IP30.<br />
Certifications and compliance<br />
No UL listing or recognition.<br />
Compliant with standards: IEC/EN 60044-1.<br />
13<br />
Dimensions<br />
page D-31<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com
PAGE 14-2<br />
ADXM06BP - ADXM12BP - ADXM18BP<br />
• Rated starter current Ie 6 to 18A ratings<br />
• Rated motor power 1.5 to 10HP up to 600VAC<br />
• Integrated by-pass relay<br />
• Adjustable acceleration and deceleration time<br />
and initial torque<br />
• LED indicators for starter status<br />
• 35mm DIN rail mounting.<br />
PAGE 14-3<br />
ADXM25BP - ADXM45BP<br />
• Rated starter current Ie 25 to 45A ratings<br />
• Rated motor power 10 to 40HP up to 600VAC<br />
• Integrated by-pass relay<br />
• Total protection against over temperature<br />
• LED indicators for starter status<br />
• Adjustable acceleration and deceleration time<br />
and initial torque<br />
• 35mm DIN rail mounting.<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com
14<br />
SOFT STARTERS<br />
6 to 45A starter ratings<br />
Internal by-pass relay<br />
Two-pole switching<br />
Soft start and stop<br />
Initial torque control for smooth<br />
and gradual starting<br />
Total integrated motor protection.<br />
PLANET -LOGIC<br />
Soft starters<br />
SEC. PAGE<br />
1.5 to 10HP ratings up to 600VAC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14- 2<br />
10 to 40HP ratings up to 600VAC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14- 3<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com
14-2<br />
Soft starters<br />
electric<br />
ADXM...BP type Motor rating Rated starter Catalog Price<br />
Three-phase current Ie number ❶❷<br />
power<br />
51 ADXM 06BP<br />
51 ADXM 12BP<br />
51 ADXM 18BP<br />
[HP] [kW] [A in AC-53b] $ each<br />
With integrated by-pass relay.<br />
220VAC motor voltage.<br />
1.5 1.1 6 51 ADXM 06BP A220 579.00<br />
3 3 12 51 ADXM 12BP A220 707.00<br />
5 4 18 51 ADXM 18BP A220 783.00<br />
480VAC motor voltage.<br />
7.5 5.5 12 51 ADXM 12BP A480 707.00<br />
600VAC motor voltage.<br />
10 7.5 12 51 ADXM 12BP A600 707.00<br />
ADXM 06/12/12B adjustments<br />
➀ Ramp-up time 0.5 to 10s. Time from zero to full load voltage.<br />
➁ Ramp-down time 0.5 to 20s. Time from full load voltage to zero.<br />
➂ Initial torque 0 to 85% voltage at the beginning of the ramp-up function.<br />
Starting and stopping time as well as initial torque can be independently<br />
adjusted by built-in potentiometers.<br />
Led indication<br />
Motor voltage<br />
Time<br />
Description LED color Inscription<br />
Power supply on Green POWER ON<br />
Ramp up/down Yellow RAMPING<br />
(constantly on)<br />
By-pass relay Yellow BY-PASS<br />
(constantly on)<br />
General characteristics<br />
ADXM...BP is a compact soft starter, for three-phase<br />
squirrel-cage motors; it soft starts and soft stops rated<br />
motor load currents up to 18A.<br />
The soft starter reduces the mechanical load on motors,<br />
shafts, gearboxes and drive belts.<br />
The internal by-pass relay of the starter eliminates the<br />
need for external heatsinks thereby reducing space<br />
requirements in panels and generated heat.<br />
Main features are:<br />
– Suitable for three-phase induction motors up to<br />
10HP/7.5kW at 600V<br />
– 35mm DIN rail mounting (IEC/EN 60715)<br />
– Integrated by-pass relay<br />
– Low in-rush current and reduced vibrations during<br />
starting<br />
– Simple programming and installation<br />
– Ideal for conveyor belts, compressors, pumps,<br />
hoisting equipment, blowers, fans and mixers.<br />
Operational characteristics<br />
– Number of controlled phases: Two<br />
– Controlled operational voltage L1-L2.L3:<br />
220VAC -15/+10% for ADXM...BP A220 types ❶<br />
480VAC -15/+10% for ADXM 12BP A480 ❷<br />
600VAC -15/+10% for ADXM 12BP A600 ❷<br />
– Rated AC frequency: 50/60Hz ±10% (self-configurable)<br />
– Auxiliary control power: A1-A2 - 24-110VAC/DC ±15%<br />
A1-A3 - 110-480VAC ±15%<br />
– Min-max control input current: 1-5mA<br />
– Method of starting and stopping: Voltage control<br />
– Start time adjustment - ramp up: 0.5 to 10 seconds<br />
– Stop time adjustment - ramp down: 0.5 to 20 seconds<br />
– Start torque adjustment - initial torque: 0-85% voltage<br />
– Minimum operating current: 250mA<br />
– Termination:<br />
• Line: 6 cage clamp type with M4 screw<br />
• Secondary: 7 cage clamp type with M3 screw<br />
– Conductor cross section:<br />
• Line: 14...8 AWG / flexible 2.5...10mm 2 or 2 - 4mm 2<br />
• Secondary: 22...12 AWG / flexible 0.5...1.5mm 2<br />
– Maximum tightening torque (tool):<br />
• Line: 22lbin / 2.5Nm (Pozidrive 2)<br />
• Secondary: 4.5lbin / 0.5Nm (Phillips 0)<br />
– Degree of protection: IP20<br />
– Natural cooling system<br />
– Ambient conditions:<br />
• Operating temperature: -4...+140°F (-20...+60°C)<br />
• Storage temperature: -58...+185°F (-50...+85°C)<br />
• Relative humidity:
electric<br />
Soft starters 14-3<br />
ADXM...BP type Motor rating Rated starter Catalog Price<br />
Three-phase current Ie number ❶❷<br />
power<br />
51 ADXM 25BP<br />
51 ADXM 45BP<br />
[HP] [kW] [A in AC-53b] $ each<br />
With integrated by-pass relay.<br />
220VAC motor voltage.<br />
10 5.5 25 51 ADXM 25BP A220 978.00<br />
15 11 45 51 ADXM 45BP A220 2106.00<br />
480VAC motor voltage.<br />
20 15 25 51 ADXM 25BP A480 978.00<br />
30 30 45 51 ADXM 45BP A480 2106.00<br />
600VAC motor voltage.<br />
25 18.5 25 51 ADXM 25BP A600 978.00<br />
40 30 45 51 ADXM 45BP A600 2106.00<br />
ADXM 25/45BP adjustments<br />
Motor voltage<br />
Time<br />
➀ Ramp-up time 1 to 10s. Time from zero to full load voltage.<br />
➁ Ramp-down time 1 to 30s. Time from full load voltage to zero.<br />
➂ Initial torque 0 to 70% voltage at the beginning of the ramp-up function.<br />
Starting and stopping time as well as initial torque can be independently<br />
adjusted by built-in potentiometers.<br />
Led indication<br />
Description LED color Inscription<br />
Power supply on Green POWER ON<br />
Ramp up/down Yellow RAMPING<br />
(flashing)<br />
By-pass relay Yellow BYPASS<br />
(constantly on)<br />
Over temperature Red OVERHEAT<br />
inside starter (flashing)<br />
Over temperature Red<br />
in motor (PTC) (constantly on)<br />
Wrong phase Red WRONG SEQ<br />
sequence ❸ (flashing)<br />
Phase failure/loss ❸ Red PHASE LOSS<br />
(fast flashing)<br />
Voltage too low Red<br />
(slow flashing)<br />
❸ These protections are active at power on only.<br />
General characteristics<br />
ADXM...BP is a compact soft starter, for three-phase<br />
squirrel-cage motors; it soft starts and soft stops rated<br />
motor load currents up to 45A.<br />
The soft starter reduces the mechanical load on motors,<br />
shafts, gearboxes and drive belts.<br />
The internal by-pass relay of the starter eliminates the<br />
need for external heatsinks thereby reducing space<br />
requirements in panels and generated heat.<br />
Main features are:<br />
– Suitable for three-phase induction motors up to<br />
40HP/30kW at 600V<br />
– 35mm DIN rail mounting (IEC/EN 60715)<br />
– Integrated by-pass relay<br />
– Low in-rush current and reduced vibrations during<br />
starting<br />
– Full protection against over temperature<br />
– Simple programming and installation<br />
– Ideal for conveyor belts, compressors, pumps,<br />
hoisting equipment, blowers, fans and mixers.<br />
Operational characteristics<br />
– Number of controlled phases: Two<br />
– Controlled operational voltage L1-L2.L3:<br />
220VAC -15/+10% for ADXM...BP A220 types ❶<br />
480VAC -15/+10% for ADXM...BP A480 ❷<br />
600VAC -15/+10% for ADXM...BP A600 ❷<br />
– Rated AC frequency: 50/60Hz ±10% (self-configurable)<br />
– Auxiliary control power:<br />
A1-A2 24-550VAC/DC ±15% for ADXM...BP A220<br />
and A480<br />
A1-A2 24-600VAC/DC +10% for ADXM...BP A600<br />
– Min-max control input current: 1-5mA<br />
– Method of starting and stopping: Voltage control<br />
– Start time adjustment - ramp up: 1 to 10 seconds<br />
– Stop time adjustment - ramp down: 1 to 30 seconds<br />
– Start torque adjustment - initial torque: 0-70% voltage<br />
– Minimum operating current: 500mA<br />
– Termination:<br />
• Line: 6 cage clamp type with M5 screw<br />
• Secondary: 7 cage clamp type with M3 screw<br />
– Conductor cross section:<br />
• Line: 14...4 AWG / flexible 0.75...16mm 2<br />
• Secondary: 22...14 AWG / flexible 0.75...2.5mm 2<br />
– Maximum tightening torque :<br />
• Line: 22lbin / 2.5Nm<br />
• Secondary: 4.5lbin / 0.5Nm<br />
– Degree of protection: IP20<br />
– Natural cooling system<br />
– Ambient conditions:<br />
• Operating temperature: -4...+140°F (-20...+60°C)<br />
• Storage temperature: -58...+185°F (-50...+85°C)<br />
• Relative humidity:
PAGE 15-2<br />
DCRK<br />
• Digital programming<br />
• 5 or 7 step configuration in 96x96mm housing<br />
• 8 or 12 step configuration in 144x144mm<br />
housing<br />
• Capacitor overload protection<br />
• Internal panel temperature sensor<br />
• TTL/RS232 programming interface<br />
• Automatic set-up function<br />
• Configurable alarms.<br />
PAGE 15-3<br />
DCRJ<br />
• Digital programming<br />
• 8 or 12 step configurationin 144x144mm<br />
housing<br />
• Dual displays<br />
• Independent voltage measure input<br />
• Capacitor overload protection<br />
• Internal-external panel temperature sensor<br />
• RS232 programming and supervision interface<br />
• RS485 supervision interface<br />
• Voltage and current harmonics measures<br />
• Event log<br />
• Automatic set-up function (adjustable)<br />
• Configurable alarms<br />
• Suitable for medium voltage systems.<br />
PAGE 15-3<br />
DCRJF (STATIC OUTPUTS)<br />
• Digital programming<br />
• 11 step + 1 alarm configuration in 144x144mm<br />
housing<br />
• Dual displays<br />
• Independent voltage measure input<br />
• Capacitor overload protection<br />
• Internal-external panel temperature sensor<br />
• RS232 programming and supervision interface<br />
• Voltage and current harmonics measures<br />
• Event log<br />
• Configurable alarms.<br />
DESCRIPTION DCRK DCRJ DCRJ12F<br />
Front plate<br />
3-digit display ● ● ●<br />
4-digit display supplement ● ●<br />
4 operation keys ● ● ●<br />
1 function key ● ●<br />
7 LED indicators for main functions and measures ●<br />
14 LED indicators for main functions and measures ● ●<br />
Control - Functions<br />
Automatic recognition of current flow ● ● ●<br />
4-quadrant operation ● ● ●<br />
Independent voltage input ● ●<br />
Three-phase voltage control ● ●<br />
Medium-voltage usage ● ●<br />
Phase-Neutral connection in 3-phase systems ● ●<br />
Programmable input as functional ● ●<br />
or remote temperature sensor<br />
Keypad lock ● ● ●<br />
TTL/RS232 communication interface<br />
●<br />
RS232 communication interface ● ●<br />
Isolated RS485 communication interface ● ●<br />
Automatic set-up function (adjustable) ● ●<br />
Easy current transformer setting function ● ● ●<br />
Set-up and automatic panel test software ● ●<br />
Remote supervision software ● ●<br />
Real time clock with back-up battery ● ●<br />
Current and voltage waveform captures, ● ●<br />
related to harmonic events<br />
Events logging such as: alarms, power ON, ● ●<br />
power OFF, set-up changes, etc.<br />
Measurements<br />
Instantaneous displacement power factor (cosϕ) ● ● ●<br />
Instantaneous and average weekly power factor ● ● ●<br />
Voltage and current ● ● ●<br />
Reactive power to reach set-point value ● ● ●<br />
Total reactive power ● ● ●<br />
Capacitor overload ● ● ●<br />
<strong>Electric</strong> panel temperature ● ● ●<br />
Maximum voltage and current value ● ● ●<br />
Maximum capacitor overload value ● ● ●<br />
Maximum panel temperature value ● ● ●<br />
Maximum capacitor temperature value ● ●<br />
Active and apparent power ● ●<br />
Current and voltage harmonic analysis ● ●<br />
Current and voltage harmonic waveform ● ●<br />
logged at overload events<br />
Step “var” value ● ●<br />
Number of switching measures per step ● ●<br />
Protection functions<br />
Voltage too high and too low ● ● ●<br />
Current too high and too low ● ● ●<br />
Over compensation (capacitors disconnected ● ● ●<br />
and cosϕ higher than set-point)<br />
Under compensation (capacitors connected ● ● ●<br />
and cosϕ lower than set-point)<br />
Capacitor overload ● ● ●<br />
Capacitor overload on all 3 phases ● ●<br />
Over temperature ● ● ●<br />
No-voltage release protection ● ● ●<br />
Capacitor bank failure ● ●<br />
Over maximum harmonic distortion level limit ● ●<br />
Programmable alarm properties ● ● ●<br />
(enable, trip delay, relay energising, etc.)<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com
15<br />
AUTOMATIC POWER FACTOR CONTROLLERS<br />
Microprocessor supervision<br />
and control<br />
Accurate current evaluation<br />
with RMS readings<br />
Automatic intelligent adjustment<br />
Version with 5, 7, 8 or 12 steps<br />
Use in co-generation systems<br />
Communication serial interfaces<br />
ASCII and Modbus®-RTU<br />
communication protocols.<br />
PLANET -LOGIC<br />
Automatic power factor controllers<br />
SEC. PAGE<br />
DCRK series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15- 2<br />
DCRJ series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15- 3<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com
15-2<br />
Automatic power factor controllers<br />
electric<br />
DCRK Series<br />
DCRK5<br />
DCRK8<br />
Example of main window frame using DCRK SW software<br />
Flush-mount Steps Catalog Price<br />
housing size<br />
number<br />
[mm] n° $ each<br />
96x96 5 DCRK 5 460 480.00<br />
96x96 7 DCRK 7 460 540.00<br />
144x144 8 DCRK 8 460 765.00<br />
144x144 12 DCRK 12 460 885.00<br />
96x96mm = 3.78x3.78in<br />
144x144mm = 5.67x5.67in<br />
Description Catalog Price<br />
number<br />
$ each<br />
Software.<br />
Set-up and automatic test software DCRK SW 430.00<br />
complete with 51 C11 connecting<br />
wire<br />
Accessories and spare parts.<br />
PC ↔ DCRK connecting wire for 51 C11 230.00<br />
TTL/RS232 communication port,<br />
9ft (2.8m) long<br />
IP54 front sealable cover for 31 PA96X96 34.00<br />
DCRK5 and DCRK7<br />
IP54 front protective cover for 31 PACR 40.00<br />
DCRK8 and DCRK12<br />
General characteristics<br />
– 5, 7, 8 and 12 step versions, the last two of which are<br />
programmable as alarm and/or fan control<br />
– Digital microprocessor regulator for automatic power<br />
factor correction systems with output relays for the<br />
connection and disconnection of capacitor banks<br />
– For co-generation systems; 4 quadrant operation<br />
– Accurate and reliable power factor control of a system<br />
even in presence of high current and voltage<br />
harmonic content<br />
– Provides for increased capacitor life by intelligent<br />
control of the capacitor operation and connection time<br />
– RMS voltage and current measurements<br />
– Average weekly power factor measurement (last 7<br />
days)<br />
– Adjustable tripping sensitivity, integral switching time<br />
– Adjustable reconnection time delay<br />
– No-voltage release protection<br />
– Protection against capacitor overload and panel<br />
overheating<br />
– Automatic set-up function<br />
– TTL-RS232 interface with personal computer for:<br />
fast set-up, function and alarm personalizing and<br />
automatic electric panel testing<br />
– Installation ease with the use of one external current<br />
transformer only.<br />
Operational characteristics<br />
– Voltage circuit<br />
• Input and control power Ue: 440-480VAC<br />
(220-240VAC or 380-415VAC or 480-525VAC on<br />
request)<br />
• Rated frequency: 50/60Hz ±1% self configurable<br />
• Power consumption: 6.2VA (DCRK5 and DCRK7)<br />
5VA (DCRK8 and DCRK12)<br />
– Current circuit<br />
• Rated current Ie: 5A (1A on request)<br />
• Overload peak: 20Ie for 10ms<br />
• Power consumption: 0.65W<br />
– Measurements and controls<br />
• Power factor adjustment:<br />
0.8 inductive - 0.8 capacitive<br />
• Voltage measurement range: -15 to +10% Ue<br />
• Current measurement range: 2.5 to 120% Ie<br />
• Temperature measurement range: -22 to +185°F<br />
(-30 to +85°C)<br />
• Capacitor overload current range: 0-250%<br />
• Type of voltage and current measurement: RMS<br />
• Reconnection time of same step: 5-240s<br />
• Tripping sensitivity: 5-600s/step<br />
– Output relays<br />
• 5, 7, 8 or 12 steps, the last of which is isolated<br />
• Contact configuration: Normally Open (NO); the last<br />
contact of DCRK8-DCRK12 is double throw<br />
• Rated current Ith: 5A 250VAC (AC1)<br />
• Maximum capacity of common terminal: 12A<br />
• Rated operational voltage: 250VAC<br />
• UL designation: B300<br />
• Maximum switchable voltage: 440VAC<br />
– Housing<br />
• Flush mounting<br />
• Degree of protection on front:<br />
IP54 for DCRK5 and DCRK7.<br />
IP41 for DCRK8 and DCRK12; IP54 with protective<br />
cover<br />
15<br />
Certifications and compliance<br />
UL listed for USA and Canada, File E93601.<br />
Compliant with standards: IEC/EN 61010-1,<br />
IEC/EN 61000-6-2, CISPR 11/EN 55011.<br />
Special contactors for power factor correction<br />
See section 3, page 3-8.<br />
Dimensions<br />
page D-32<br />
Wiring diagrams<br />
page W-19<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com<br />
Technical characteristics<br />
page TC-46
electric<br />
Automatic power factor controllers 15-3<br />
DCRJ series<br />
DCRJ8<br />
Example of main window frame using DCRJ SW software<br />
Flush-mount Steps Catalog Price<br />
housing size<br />
number<br />
[mm] n° $ each<br />
Version with relay outputs.<br />
144x144 8 DCRJ 8 1235.00<br />
144x144 12 DCRJ 12 1320.00<br />
Version with static outputs.<br />
144x144 11+1 relay DCRJ12F 1650.00<br />
output<br />
144x144mm = 5.67x5.67in<br />
Description Catalog Price<br />
number<br />
$ each<br />
Software.<br />
Set-up / automatic test / remote DCRJ SW 950.00<br />
control software complete with<br />
51 C2 connecting wire<br />
Accessories and spare parts.<br />
PC ↔ DCRJ connecting 51 C2 60.00<br />
cable, 6ft (1.8m) long<br />
PC ↔ 4 PX1 converter 51 C4 65.00<br />
connecting cable, 6ft (1.8m) long<br />
DCRJ ↔ Analog modem 51 C5 69.00<br />
connecting cable, 6ft (1.8m) long❶<br />
4 PX1 ↔ Analog modem 51 C9 83.00<br />
connecting cable, 6ft (1.8m) long<br />
RS232/RS485 converter drive, 4 PX1 115 707.00<br />
opto-isolated, 110-120VAC❷<br />
Temperature sensor NTC 01 36.00<br />
Front protective cover, 31 PACR 40.00<br />
IP54 protection<br />
❶ “3Com-U.S. Robotics” 56k V.92 modem with RS232 interface, complete with<br />
PC connecting cable, compatible with LOVATO ELECTRIC remote control<br />
software.<br />
❷ RS232/RS485 opto-isolated converter drive, 38,400 Baud-rate maximum,<br />
automatic or manual TRANSMIT line supervision.<br />
General characteristics<br />
– 8 and 12 step versions (DCRJ8-DCRJ12), the last two<br />
of which are programmable as alarm and/or fan control<br />
– Version (DCRJ12F) with 11 static output plus 1 alarm<br />
relay output<br />
– Digital microprocessor regulator for automatic power<br />
factor correction systems with output relays for the<br />
connection and disconnection of capacitor banks<br />
– For medium voltage systems (separate voltage input)<br />
and co-generation (4 quadrant operation)<br />
– Accurate and reliable power factor control of a system<br />
even in presence of high current and voltage harmonic<br />
content<br />
– Provides for increased capacitor life by inteligent<br />
control of the capacitor operation and connection time<br />
– RMS voltage and current measure<br />
– Measure of average weekly power factor (last 7 days),<br />
capacitor overload, electric panel temperature, voltage<br />
and current harmonic content<br />
– Event viewing when harmonic overload limit exceeded<br />
– Harmonic content analysis of logged events complete<br />
with relative waveforms<br />
– Adjustable tripping sensitivity, integral switching time<br />
– Adjustable reconnection time delay (DCRJ8-DCRJ12)<br />
– No-voltage release protection<br />
– Protection against capacitor overload and panel<br />
overheating<br />
– Panel temperature sensor<br />
– Connection to remote NTC temperature sensor<br />
– Automatic set-up function (programmable on DCRJ8<br />
and DCRJ12)<br />
– RS232 and RS485 serial ports<br />
– Remote supervision software for personal computer<br />
interface and supervision for: fast set-up, function and<br />
alarm customising and automatic electric panel testing<br />
– Modbus ® -RTU and ASCII communication protocols<br />
– Configuration of mixed static and electromechanical<br />
steps (DCRJ12F).<br />
Operational characteristics<br />
– Supply circuit<br />
• Dual control power Ue: 110-127 / 220-240VAC<br />
• Rated frequency: 50/60Hz ±5% self configurable<br />
• Power consumption:9.7VA for DCRJ8-DCRJ12;<br />
9.2VA for DCRJ12F<br />
– Voltage circuit<br />
• Three phases without neutral<br />
• Measuring rated voltage: 100-690VAC<br />
– Current circuit<br />
• Rated current Ie: 5A (1A on request)<br />
• Overload peak: 20Ie for 10ms<br />
• Power consumption: 0.3VA<br />
– Measurements and controls<br />
• Type of voltage and current measurement: RMS<br />
• Voltage measurement range: 85-760VAC<br />
• Current measurement range: 2.5 to 120% Ie<br />
• External temperature measurement range:<br />
-40 to +185°F (-40 to +85°C)<br />
• Capacitor overload current range: 0-250%<br />
• Power factor adjustment: 0.8 inductive - 0.8 capacitive<br />
• Reconnection time of same step: 5-240s for DCRJ8-<br />
DCRJ12 only<br />
• Tripping sensitivity: 5-600s/step<br />
• Sampling time: ≈20ms for DCRJ12F<br />
– Output relays for DCJ8-DCRJ12<br />
• 8 or 12 steps, the last of which is isolated<br />
• Contact configuration: Normally Open (NO); the last<br />
of which is double throw<br />
• Rated current Ith: 5A 250VAC (AC1)<br />
• Maximum capacity of common terminal: 12A<br />
• Rated operational voltage: 250VAC<br />
• UL designation: B300<br />
• Maximum switchable voltage: 440VAC<br />
– Outputs for DCRJ12F<br />
• 11 static outputs for static contactors control<br />
• 1 alarm relay output<br />
• Opto-isolated bi-directional static outputs (Opto-Mosfet)<br />
• Maximum operational voltage: 40VDC; 30VAC<br />
• Maximum operational current: 55mA<br />
– Housing<br />
• Flush mounting<br />
• Degree of protection on front: IP41; IP54 with<br />
protective cover.<br />
Certifications and compliance<br />
UL listed for USA and Canada, File E93601.<br />
Compliant with standards: IEC/EN 61010-1,<br />
IEC/EN 61000-6-2, CISPR 11/EN 55011.<br />
Special contactors for power factor correction<br />
See section 3, page 3-8.<br />
15<br />
Dimensions<br />
page D-32<br />
Wiring diagrams<br />
page W-19<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com<br />
Technical characteristics<br />
page TC-46
PAGE 16-2<br />
ATL20<br />
• Automatic transfer switch controller with<br />
RS232 port<br />
• AC/DC auxiliary supply.<br />
PAGE 16-3<br />
ATL30<br />
• Automatic transfer switch controller with<br />
RS232 and RS485 ports<br />
• Real time clock<br />
• AC/DC auxiliary supply.<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com
16<br />
AUTOMATIC TRANSFER SWITCH CONTROLLERS<br />
Supervision of two supply lines<br />
Emergency demand supervision for<br />
stand-by generating set<br />
Supervision of motorized manual<br />
starters<br />
Event logging<br />
TRMS measures of voltage values<br />
Microprocessor remote control and<br />
supervision<br />
RS232 and RS485 serial ports<br />
Modbus ® -RTU and Modbus ® -ASCII<br />
communication protocols<br />
Real time clock.<br />
PLANET -LOGIC<br />
Automatic transfer switch controllers<br />
SEC. PAGE<br />
ATL20 type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16- 2<br />
ATL30 type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16- 3<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com
Automatic transfer switch controllers<br />
16-2<br />
electric<br />
Standard version<br />
with RS232 port<br />
ATL20 A120<br />
Description Catalog Price<br />
number<br />
$ each<br />
Controller with RS232 port ATL20 A120 1255.00<br />
Software.<br />
Set-up software complete ATL SW 965.00<br />
with 51 C2 cable<br />
Accessories.<br />
PC ↔ ATL connecting cable, 9ft (2.8m) 51 C2 60.00<br />
long, for RS232/TTL communication<br />
Front IP54 protective cover 31 PACR 40.00<br />
General characteristics<br />
The automatic transfer switch controller ATL is used for<br />
the automatic switching of the load from the MAIN LINE<br />
to a stand-by or emergency SECONDARY LINE and vice<br />
versa.<br />
It is made of a single unit in an insulated housing and<br />
has two outputs for the “automatic” and/or “manual”<br />
control of contactors or motorized manual starters.<br />
The controller has the following main features:<br />
– Dual supply input: One for AC and the other for<br />
battery supply<br />
– Measure inputs of three-phase plus neutral voltages,<br />
also suitable for 1 and 2-phase lines<br />
– 2 displays to view main and secondary line measures<br />
– 22 status LED indicators<br />
– 8 digital inputs, 6 of which programmable<br />
– 7 relay outputs, 5 of which programmable<br />
– 4 operating modes: OFF-MAN-AUT-TEST<br />
– Viewing of phase and phase-to-phase line voltage<br />
measures<br />
– Viewing of motorized manual starters or contactors<br />
status<br />
– Configuration programming of lines and control<br />
parameters<br />
– Emergency demand supervision parameter<br />
programming for stand-by generating sets<br />
– Microprocessor supervision of functions<br />
– RS232 communication interface<br />
– Modbus ® -RTU and Modbus ® -ASCII communication<br />
protocols<br />
– Set-up and remote control software via direct PC<br />
connection, desk or GSM modem or Ethernet<br />
network.<br />
CONTROL FUNCTIONS OF THE LINES<br />
– Phase sequence and phase loss<br />
– Minimum and maximum voltage<br />
– Voltage asymmetry<br />
– Minimum and maximum frequency.<br />
Operational characteristics<br />
– Auxiliary supply<br />
• Control power: 12-24-48VDC and 110-120VAC<br />
• Operating range: 9-70VDC; 93.5-132VAC<br />
• Power consumption: 6VA at 120VAC<br />
• Power dissipation: 2.8W at 48VDC or 120VAC<br />
• Current consumption: 420mA at 12VDC; 200mA at<br />
24VDC; 100mA at 48VDC<br />
• Frequency range: 45-65Hz.<br />
– Voltage measurement inputs<br />
• Rated voltage Ue: 690VAC phase-phase; 400VAC<br />
phase-neutral<br />
• Measurement range: 80-800VAC phase-phase<br />
• Frequency range: 45-65Hz.<br />
– Digital inputs<br />
• Negative type of inputs<br />
• Input current: ≤10mA.<br />
– Relay outputs<br />
• 2 relay outputs, each with 1 N/O contact rated<br />
B300/16A AC1 at 250VAC<br />
• 3 relay outputs, each with 1 N/O contact rated<br />
B300/8A 8A AC1 at 250VAC<br />
• 2 relay outputs, each with 1 SPDT contact rated<br />
B300/8A AC1 at 250VAC; 1A 30VDC pilot duty.<br />
– Housing<br />
• Flush-mount 5.7x5.7in (144x144mm) version<br />
• Degree of protection:<br />
– IP20 at rear<br />
– IP41 on front, without protective cover<br />
– IP54 on front, complete with protective cover.<br />
16<br />
Certfications and compliance<br />
UL listed for USA and Canada, file E93601.<br />
Compliant with stadards: IEC/EN 60947-1,<br />
IEC/EN60947-6-1, IEC/EN61000-6-3, IEC/EN61000-6-2.<br />
Dimensions<br />
page D-33<br />
Wiring diagrams<br />
page W-20<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com<br />
Technical characteristics<br />
page TC-47
electric<br />
Automatic transfer switch controllers 16-3<br />
Version with<br />
RS232 and RS485<br />
opto-isolated<br />
ports<br />
ATL30 A120<br />
Description Catalog Price<br />
number<br />
$ each<br />
Controller with RS232 and RS485 ports ATL30 A120 1506.00<br />
and RTC<br />
Software.<br />
Set-up software complete with 51 C2 ATL SW 965.00<br />
cable<br />
Accessories.<br />
PC ↔ ATL connecting cable, 9ft (2.8m) 51 C2 60.00<br />
long<br />
PC ↔ 4 PX1 converter connecting 51 C4 65.00<br />
cable, 6ft (1.8m) long<br />
ATL ↔ Analog modem connecting 51 C5 69.00<br />
cable, 6ft (1.8m) long<br />
ATL ↔ 4 PX1 converter connecting 51 C6 60.00<br />
cable, 6ft (1.8m) long<br />
PC ↔ Analog modem connecting 51 C9 83.00<br />
cable, 6ft (1.8m) long<br />
RS232/RS485 converter drive, 4 PX1 115 707.00<br />
opto-isolated, 110-120VAC<br />
Front IP54 protective cover 31 PACR 40.00<br />
General characteristics<br />
The automatic transfer switch controller ATL is used for<br />
the automatic switching of the load from the MAIN LINE<br />
to a stand-by or emergency SECONDARY LINE and vice<br />
versa.<br />
It is made of a single unit in an insulated housing and<br />
has two outputs for the “automatic” and/or “manual”<br />
control of contactors or motorized manual starters.<br />
The controller has the following main features:<br />
– Dual supply input: One for AC and the other for<br />
battery supply<br />
– Measure inputs of three-phase plus neutral voltages<br />
also suitable for 1 and 2-phase lines<br />
– 2 displays to view main and secondary line measures<br />
– 22 status LED indicators<br />
– 8 digital inputs, 6 of which programmable<br />
– 7 relay outputs, 5 of which programmable<br />
– 4 operating modes: OFF-MAN-AUT-TEST<br />
– Viewing of phase and phase-to-phase line voltage<br />
measures<br />
– Viewing of motorized manual starters or contactors<br />
status<br />
– Configuration programming of lines and control<br />
parameters<br />
– Supervision parameter programming for emergency<br />
demand of generating sets<br />
– Microprocessor supervision of functions<br />
– RS232 communication interface<br />
– RS485 opto-isolated communication interface<br />
– Modbus ® -RTU and Modbus ® -ASCII communication<br />
protocols<br />
– Set-up and remote control software via direct PC<br />
connection or via normal modem or GSM modem or<br />
Ethernet network.<br />
CONTROL FUNCTIONS OF THE LINES<br />
– Phase sequence and phase loss<br />
– Minimum and maximum voltage<br />
– Voltage asymmetry<br />
– Minimum and maximum frequency.<br />
Operational characteristics<br />
– Auxiliary supply<br />
• Control power: 12-24-48VDC and 110-120VAC<br />
• Operating range: 9-70VDC; 93.5-132VAC<br />
• Power consumption: 6VA at 120VAC<br />
• Power dissipation: 2.8W at 48VDC or 240VAC<br />
• Current consumption: 420mA at 12VDC; 200mA at<br />
24VDC; 100mA at 48VDC<br />
• Frequency range: 45-65Hz.<br />
– Voltage measurement inputs<br />
• Rated voltage Ue: 690VAC phase-phase<br />
(400VAC phase-neutral)<br />
• Measurement range: 80-800VAC phase-phase<br />
• Frequency range: 45-65Hz.<br />
– Digital inputs<br />
• Negative type of input<br />
• Input current: ≤10mA.<br />
– Relay outputs<br />
• 2 relay outputs, each with 1 N/O contact rated<br />
B300/16A AC1 at 250VAC<br />
• 3 relay outputs, each with 1 N/O contact rated<br />
B300/8A AC1 at 250VAC<br />
• 2 relay outputs, each with 1 SPDT contact rated<br />
B300/8A AC1 at 250VAC; 1A 30VDC pilot duty.<br />
– Housing<br />
• Flush-mount 5.7x5.7in (144x144mm) version<br />
• Degree of protection:<br />
– IP20 at rear<br />
– IP41 on front, without protective cover<br />
– IP54 on front, complete with protective cover.<br />
Certfications and compliance<br />
UL listed for USA and Canada, file E93601.<br />
Compliant with stadards: IEC/EN 60947-1,<br />
IEC/EN60947-6-1, IEC/EN61000-6-3, IEC/EN61000-6-2.<br />
16<br />
Dimensions<br />
page D-33<br />
Wiring diagrams<br />
page W-20<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com<br />
Technical characteristics<br />
page TC-47
PAGE 17-2<br />
PROGRAMMABLE LOGIC RELAYS<br />
• Versions with:<br />
6 inputs + 4 outputs<br />
8 inputs + 4 outputs<br />
12 inputs + 8 outputs<br />
• 24VDC, 24VAC or 110-240VAC control power<br />
• Relay or transistor outputs.<br />
PAGE 17-2<br />
EXPANSION MODULES<br />
• Variants with a total of 8 inputs/outputs<br />
• 24VDC, 24VAC or 110-240VAC control power<br />
• Relay or transistor outputs.<br />
PAGE 17-2<br />
STARTER KITS<br />
• Complete kit to begin using the programmable<br />
relays<br />
• Each equipped with LRD relay, programmingsupervision<br />
software and connecting cable.<br />
PAGE 17-3<br />
LOGIC RELAY ACCESSORIES<br />
• Communication and memory modules<br />
• Power supply unit<br />
• Supervision software.<br />
LOGIC FUNCTIONS<br />
10 different operating modes:<br />
– AND - Consent simultaneity (series connection of contact)<br />
– AND - Consent simultaneity with edge evaluation<br />
– NAND - No simultaneity (parallel connection of contact)<br />
– NAND - Simultaneity loss with edge evaluation<br />
– OR - At least one consent (parallel connection of contact)<br />
– NOR - No consents (series connection of contact)<br />
– XOR - 2 signals of diverse state (dual changeover contact)<br />
– NOT - State inverter<br />
– Pulse - Pulse output<br />
– SR - Two distinct signals for permanent enable and<br />
disable.<br />
TIMERS (15 maximum)<br />
7 different operating modes:<br />
– ON delay - standard<br />
– ON delay - sum of time at enable and reset signals<br />
– OFF delay - output enable on up time, off on down time<br />
– OFF delay - output enable and off on down input<br />
– Recycle - input signal always enabled (equal timing)<br />
– Recycle - output enable on input and enable resets up<br />
time (equal timing)<br />
– Recycle - on-off intervals with independent timing.<br />
RTC - REAL TIME CLOCK (15 maximum)<br />
3 different operating modes:<br />
– Daily - choice of days of the week (from ... to) and daily<br />
hours (from ... to)<br />
– Weekly - choice of week day and hours to begin and end<br />
of week day<br />
– Yearly - choice of date to begin and end.<br />
COUNTERS (15 maximum)<br />
8 different operating modes (up and down):<br />
– Without over-counting and no retain at power loss<br />
– With over-counting function and no retain at power loss<br />
– Without over-counting and retain function at power loss<br />
– With over-counting and retain function at power loss<br />
– With over-counting and no retain at power loss and reset<br />
to 0<br />
– With over-counting and retain function at power loss and<br />
reset to 0<br />
– High speed counter<br />
– Frequency comparison.<br />
ANALOG COMPARATORS (15 maximum)<br />
5 different operating modes:<br />
– Comparators for analog inputs<br />
– Comparators for analog inputs and constants<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com
17<br />
PROGRAMMABLE LOGIC RELAYS<br />
Suitable for small automated and<br />
control systems<br />
Quick and easy to program,<br />
versatile and expandable<br />
Activation of logic control, timer,<br />
counter, real time clock, analog<br />
comparators functions<br />
FBD and LADDER program<br />
language logic.<br />
PLANET -LOGIC<br />
SEC. PAGE<br />
Programmable logic relays<br />
Base control units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17- 2<br />
Expansion modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17- 2<br />
Starter kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17- 2<br />
Accessories<br />
Communication, backup memory and power supply units . . . . . . . . . . . . . . . . . . . 17- 3<br />
Software, connecting cable, manuals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17- 3<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com
17-2<br />
Programmable logic relays<br />
®<br />
electric<br />
Relay modules<br />
with RS232 port<br />
Control RTC Catalog Price<br />
power<br />
number<br />
INPUTS<br />
OUTPUTS<br />
Total Digital/Analog❷ Digital<br />
(0-10VDC)<br />
$ each<br />
n° n° n° Type<br />
Base control modules.<br />
24VDC Yes LRD12R D024 295.00<br />
8 2 4 Relay<br />
24VDC Yes LRD12T D024 288.00<br />
8 2 4 Transistor<br />
24VDC Yes LRD20R D024 435.00<br />
12 4 8 Relay<br />
24VDC Yes LRD20T D024 420.00<br />
12 4 8 Transistor<br />
24VAC Yes LRD12R A024 310.00<br />
8 0 4 Relay<br />
LRD10R A240<br />
24VAC Yes LRD20R A024 435.00<br />
100-240VAC Yes LRD10R A240 310.00<br />
12 0 8 Relay<br />
6 0 4 Relay<br />
100-240VAC Yes LRD20R A240 435.00<br />
12 0 8 Relay<br />
Expansion modules.<br />
24VDC No LRE08R D024 175.00<br />
4 0 4 Relay<br />
24VDC No LRE08T D024 165.00<br />
4 0 4 Transistor<br />
24VAC No LRD08R A024 175.00<br />
4 0 4 Relay<br />
100-240VAC No LRE08R A240 175.00<br />
4 0 4 Relay<br />
17<br />
LRD20R A240<br />
Expansion modules<br />
LRE08R A240<br />
Starter kits<br />
LRDKIT 10R A024<br />
Starter kits.<br />
LR relay kit complete with 8I/4O LRDKIT 12R D024 405.00<br />
24VDC relay, LRX C00<br />
connecting cable and LRX SW<br />
programming / supervision<br />
software<br />
LR relay kit complete with 6I/4O LRDKIT 10R A240 420.00<br />
100-240VAC relay, LRX C00<br />
connecting cable and LRX SW<br />
programming / supervision<br />
software<br />
LR relay kit complete with 8I/4O LRDKIT 12R A024 420.00<br />
24VAC relay, LRX C00<br />
connecting cable and LRX SW<br />
programming / supervision<br />
software<br />
Kinco can be easily adapted to every type of need. The number of<br />
inputs and outputs of the control module can be directly increased<br />
by using the expansion modules.<br />
The programmable relay is compact in size and has an excellent<br />
performance suitable for the control and supervision of low and<br />
medium complexity automatisms.<br />
It can be used in diverse applications, including industrial,<br />
commercial and residential. It combines the functions of<br />
numerous traditional devices, such as control relays, timers,<br />
counters, hour meters and other parts.<br />
LRD10<br />
LRD12<br />
LRD20<br />
LRE08<br />
Kinco Expansions Total number of<br />
Inputs/Outputs<br />
LRD10<br />
10 (6 Inputs + 4 Outputs)<br />
+ LRE08 18 (10 Inputs + 8 Outputs)<br />
+ LRE08 + LRE08 26 (14 Inputs + 12 Outputs)<br />
+ LRE08 + LRE08 + LRE08 34 (18 Inputs + 16 Outputs)<br />
LRD12<br />
12 (8 Inputs + 4 Outputs)<br />
+ LRE08 20 (12 Inputs + 8 Outputs)<br />
+ LRE08 + LRE08 28 (16 Inputs + 12 Outputs)<br />
+ LRE08 + LRE08 + LRE08 36 (20 Inputs + 16 Outputs)<br />
LRD20<br />
20 (12 Inputs + 8 Outputs)<br />
+ LRE08 28 (16 Inputs + 12 Outputs)<br />
+ LRE08 + LRE08 36 (20 Inputs + 16 Outputs)<br />
+ LRE08 + LRE08 + LRE08 44 (24 Inputs + 20 Outputs)<br />
❷ Digital inputs can be used as analog inputs.<br />
General characteristics<br />
Maximum configuration up to 44 inputs/outputs with a<br />
control and three expansion modules.<br />
Main features also include:<br />
– RS232 serial interface port for PC or program<br />
back-up memory connection<br />
– 4-line 12-character display with backlight<br />
– Programming language logics: Ladder for 200 lines<br />
maximum or FBD (Function Block Diagram) for 99<br />
blocks maximum<br />
– On-board programming languages: Italian, English,<br />
Spanish, French, German, Portuguese and Chinese<br />
– PC programming languages: Italian, English, Spanish<br />
Operational characteristics<br />
– Control power: 24VDC or 100-240VAC depending on<br />
module<br />
– Operating limits: 21.6-26.4VDC; 85-2264VAC<br />
– Digital inputs<br />
• Input voltage:<br />
For state 0:
®<br />
electric<br />
Programmable logic relays 17-3<br />
Accessories<br />
LRX 1V3 D024<br />
Description Catalog Price<br />
number<br />
$ each<br />
Modbus ® protocol communication LRE P00 480.00<br />
module<br />
Power supply switching module, LRX 1V3 D024 150.00<br />
100-240VAC/24VDC 1.3A<br />
PC ↔ LRD module connecting LRX C00 140.00<br />
cable, 5.9ft (1.8m) long<br />
User’s manual in Italian in CD LRX D00 40.00<br />
format<br />
User’s manual in English in CD LRX D01 40.00<br />
format<br />
User’s manual in Spanish in CD LRX D02 40.00<br />
format<br />
Program back-up memory LRX M00 40.00<br />
Programming and supervision LRX SW 50.00<br />
software for PC, in CD format<br />
General characteristics<br />
The power supply module produces a direct-current<br />
voltage needed to supply the control and expansion<br />
modules when a 24VDC power source is not available.<br />
It can also be used to power eventual other 24VDC<br />
auxiliary circuits.<br />
The backup memory allows the user’s program to be<br />
saved and then simply and quickly transferred to other<br />
Kinco control modules.<br />
The communication module implements Modbus ®<br />
protocol.<br />
Kinco can be set up and reprogrammed to satisfy new<br />
requirements or to enhance the operation of a system.<br />
Programming is simple and intuitive, can be done either<br />
directly on the relay keypad or by personal computer,<br />
connected by the interface cable, using the relative<br />
LRX SW software.<br />
Kinco has a simulator option. The user can control the<br />
exactness of the implemented program in off-line<br />
simulation, directly on the PC, before on-line testing and<br />
system setup are carried out.<br />
Base unit inputs state<br />
123456789ABC<br />
RUN MO10:31<br />
Base unit outputs state<br />
Date and time LRD state<br />
I/O STATUS<br />
DATA<br />
Certifications and compliance<br />
UL listed for USA and Canada, file E300049, for power<br />
supply module only.<br />
Compliant with standards: IEC/EN 61131-2.<br />
Expansion inputs state<br />
123456789ABC<br />
Expansion outputs state<br />
19.09.05 Date<br />
KEY<br />
MENU<br />
1123456789ABC<br />
DEF -<br />
A1=1.25<br />
A2=0.00<br />
A3=2.40<br />
A4=6.59<br />
A5=5.35<br />
A6=0.10<br />
A7=2.70<br />
A8=8.32<br />
Memory, timer, counter,<br />
RTC and analog<br />
comparator state<br />
Value of analog inputs<br />
Value of analog inputs<br />
KEY<br />
I/O STATUS<br />
PLC STATUS<br />
TIME<br />
Analogs<br />
STATUS 1<br />
KEY<br />
ESC<br />
LADDER---------- 1<br />
FBD -------------- 2<br />
RUN -------------- 3<br />
CLEAR PROG. --- 4<br />
WRITE------------ 5<br />
READ------------- 6<br />
SET--------------- 7<br />
RTC SET --------- 8<br />
ANALOG SET ---- 9<br />
PASSWORD----- 10<br />
LANGUAGE ----- 11<br />
INITIAL --------- 12<br />
ID SET 01<br />
REMOTE I \O N<br />
BACKL I GHT x<br />
7 M K E E P √<br />
I \O NUMBER: 0<br />
I \ O A L A RM : √<br />
C K E E P x<br />
1<br />
I1-M1----(Q1<br />
I2-<br />
Q1-m1----(T1<br />
8<br />
RTC SET V1 . 4<br />
05.09.19<br />
MO 13:43<br />
2<br />
3<br />
4<br />
5<br />
1<br />
1<br />
RUN PROG .<br />
> Y E S<br />
NO<br />
CLEAR<br />
> Y E S<br />
NO<br />
WR I T E<br />
> Y E S<br />
NO<br />
10.00 T1<br />
PROG.<br />
9<br />
A1=GA IN: 010<br />
OFFSET :+00<br />
A2=GA IN: 010<br />
OFFSET :+00<br />
A3=GA IN: 010<br />
OFFSET :+00<br />
A4=GA IN: 010<br />
OFFSET :+00<br />
PASSWORD<br />
0000<br />
10<br />
11<br />
ENGL I SH<br />
FRANCA I S<br />
ESPANOL<br />
ITALIANO<br />
DEUTCH<br />
PORTUGUES<br />
CHINESE<br />
x<br />
READ<br />
INITIAL<br />
6<br />
> Y E S<br />
NO<br />
12<br />
>LADDER<br />
FBD<br />
17<br />
Dimensions<br />
page D-33<br />
Wiring diagrams<br />
page W-21<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com<br />
Technical characteristics<br />
page TC-48
Dimensions<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com
D<br />
Dimensions<br />
®<br />
electric<br />
®<br />
electric<br />
100% electricity<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com
D-2<br />
Dimensions [mm (in)]<br />
Manual motor starters and protectors<br />
electric<br />
Manual starters SM1B<br />
with front and side-mount auxiliary contacts<br />
80.5 (3.17")<br />
18 (0.71") 9 (0.39")<br />
SMX12<br />
D<br />
88 (3.46")<br />
91 (3.58")<br />
35.3<br />
(1.39")<br />
44.5 (1.75")<br />
55.5 (2.18")<br />
SMX14<br />
SMX15<br />
SMX16<br />
44.5 (1.75") 4.8(0.19")<br />
44.4 (1.75")<br />
SMX13 11<br />
23.5<br />
(0.92")<br />
72.2 (2.84")<br />
82.5 (3.25")<br />
SMX11 11<br />
SMX11 20<br />
Manual starters SM1B c/w SMX90 03 connector<br />
and BG contactors<br />
44.5 (1.75")<br />
SM1B c/w SMX31 41 connector<br />
and BF09A-BF25A contactors<br />
44.5 (1.75") 85 (3.34")<br />
SM1B c/w SMX32 41 connector<br />
and BF26A-BF38A contactors<br />
44.5 (1.75") 94 (3.70")<br />
160 (6.30")<br />
SMX90 03<br />
184.2 (7.25")<br />
SMX31 41<br />
193.2 (7.60")<br />
SMX32 41<br />
Enclosures SMX17 10<br />
with SMX17 30 or SMX17 35 handle<br />
100 (3.93")<br />
Ø4.5 (0.17")<br />
134.4 (5.29")<br />
109 (4.29")<br />
SMX17 11<br />
with SMX17 40 button<br />
85.4 (3.36")<br />
Ø4.5 (0.17")<br />
173 (6.81")<br />
109 (4.29")<br />
181.2 (7.13")<br />
164 (6.45")<br />
170 (6.69")<br />
PG16<br />
42<br />
(1.65")<br />
19.2<br />
(0.75")<br />
SMX17 3...<br />
SMX17 40<br />
SMX17 20<br />
with SMX17 30 or SMX17 35 handle<br />
122 (4.80")<br />
94 (3.70")<br />
39.4<br />
(1.55")<br />
Cutout<br />
164 (6.45")<br />
144 (5.66")<br />
181.2 (7.13")<br />
170 (6.69")<br />
Ø22.5<br />
(0.88")<br />
44.1<br />
(1.73")<br />
23.1<br />
(0.91")<br />
SMX17 3...<br />
14 (0.55")<br />
122 (4.80")<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com
electric<br />
Dimensions [mm (in)]<br />
Manual motor starters and protectors<br />
D-3<br />
Manual starters SM2A<br />
with side-mount SMX2... blocks<br />
10 (0.39")<br />
SMX22<br />
17<br />
(0.67") 20<br />
(0.79")<br />
SMX24<br />
SMX25<br />
SMX26<br />
121 (4.76")<br />
102 (4.2")<br />
52 (2.05")<br />
SM2A<br />
with SMX28 05 or SMX28 10 handle<br />
121 (4.76")<br />
102 (4.2")<br />
52 (2.05")<br />
13.11<br />
(0.52") 1...4<br />
(0.04...0.16")<br />
SMX28 05<br />
SMX28 10<br />
D<br />
125 (4.92")<br />
89 (3.50")<br />
45 (1.77")<br />
85 (3.35")<br />
130 (5.12")<br />
140 (5.51")<br />
5<br />
(0.20")<br />
5<br />
(0.20")<br />
9 (0.35")<br />
18 (0.71")<br />
30<br />
(1.18")<br />
55 (2.17")<br />
SMX23 11<br />
18 (0.71")<br />
8 (0.31")<br />
109 (4.29")<br />
127 (5,00")<br />
132 (5.20")<br />
144 (5.67")<br />
8 (0.31")<br />
109 (4.29")<br />
127 (5,00")<br />
132 (5.20")<br />
144 (5.67")<br />
min. 55 (2.16")<br />
max 327 (12.93")<br />
33<br />
(1.3")<br />
17 (0.69")<br />
Manual starters SM3A<br />
with side-mount SMX2... blocks<br />
SM3A<br />
with SMX28 05 or SMX28 10 handle<br />
12<br />
SMX22<br />
(0.47")<br />
23 (0.91")<br />
SMX24<br />
SMX25<br />
SMX26<br />
146 (5.75")<br />
138 (5.43")<br />
127 (5.00")<br />
77 (3.03")<br />
147 (5.78")<br />
138 (5.43")<br />
127 (5.00")<br />
77 (3.03")<br />
13.11<br />
(0.52") 1...4<br />
(0.04...0.16")<br />
SMX28 05<br />
SMX28 10<br />
165 (6.58")<br />
155 (6.18")<br />
89 (3.50")<br />
45 (1.77")<br />
116 (4.57")<br />
150 (5.91")<br />
5<br />
(0.20")<br />
5<br />
(0.20")<br />
min. 55 (2.16")<br />
max 327 (12.93")<br />
33<br />
(1.3")<br />
17 (0.69")<br />
9 (0.35")<br />
18 (0.71")<br />
30<br />
(1.18")<br />
70 (2.75")<br />
SMX23 11<br />
18<br />
(0.71")<br />
8 (0.31")<br />
138 (5.43")<br />
152 (5.98")<br />
169 (6.65")<br />
8 (0.31")<br />
138 (5.43")<br />
152 (6.02")<br />
169 (6.65")<br />
Manual starters LMS25<br />
with side-mount LMH LMS contacts 25 con LMH<br />
45 (1.77")<br />
30.8<br />
(1.21")<br />
9 (0.35")<br />
80 (3.14")<br />
75 (2.94")<br />
35 (1.37")<br />
45 (1.77")<br />
4<br />
(0.16")<br />
LMH...<br />
38 (1.49")<br />
73.5 (2.89")<br />
83 (3.26")<br />
Enclosures LMZ111 -- LMZ112<br />
with LMZ106 LMZ111 stop LMZ111 button - LMZ112 - LMZ112<br />
Fixing axis<br />
and drillings<br />
LMZ113 - LMZ114<br />
LMZ113 - LMZ114<br />
LMZ113 LMZ113 - LMZ114 - LMZ114<br />
with LMZ106 stop button<br />
Cutout<br />
80 (3.14")<br />
95.5 (3.75")<br />
85 (3.34")<br />
80 (3.34") 12.5 (0.49")<br />
60 (2.36")<br />
55 (2.16")<br />
135 (5.31")<br />
M4<br />
55 (2.16")<br />
105 (4.13")<br />
39 (1.53")<br />
18.5<br />
(0.73")<br />
129 (5.07")<br />
105 (4.13")<br />
105 (4.13")<br />
LMZ106<br />
LMZ106<br />
M4<br />
69.5 (2.73")<br />
69.5 (2.73")<br />
M25<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com
D-4<br />
Dimensions [mm (in)]<br />
Disconnect switches<br />
electric<br />
Door coupling version GUS with GUSH and GUSS<br />
6 (0.24")<br />
min 80 (3.15")<br />
38 (1.50")<br />
1...4<br />
(0.04...0.16")<br />
‡80 (3.15")<br />
52 (2.05")<br />
D<br />
85 (3.35")<br />
35 (1.38")<br />
Ø22.5 (0.89")<br />
min 10 (0.39")<br />
max 14 (0.55")<br />
M4<br />
IEC style contactors<br />
DP definitive purpose contactors<br />
THREE AND FOUR-POLE BG AND DPBG MINI-CONTACTORS AND CONTROL RELAY WITH AC OR DC COIL<br />
BG mini-contactors or control relay<br />
DPBG definite purpose contactor<br />
44 (1.73")<br />
4.4 (0.17")<br />
4.4<br />
(0.17")<br />
4 (0.16")<br />
57 (2.24")<br />
BG and DPBG mini-contactors<br />
with screw terminals and RF...9 thermal relay<br />
44 (1.73")<br />
4 (0.16")<br />
57 (2.24")<br />
BGS with front PCB solder pins<br />
44<br />
(1.73")<br />
8.5 (0.34")<br />
8.5 (0.34")<br />
8.5 (0.34")<br />
44 (1.73")<br />
9.7<br />
(0.38")<br />
BGP<br />
with rear PCB solder pins<br />
4.4 (0.17")<br />
34.9<br />
(1.37")<br />
4.4 (0.17")<br />
50 (1.97")<br />
58 (2.28")<br />
94.2 (3.7")<br />
44 (1.73")<br />
44 (1.73")<br />
4.4 (0.17")<br />
34.9<br />
(1.37")<br />
BGF<br />
with Faston terminals<br />
4.4<br />
(0.17")<br />
50 (1.97")<br />
58 (2.28")<br />
3.2<br />
(0.13")<br />
fl 4 (0.16")<br />
RF...9<br />
89.2 (3.51")<br />
7.6<br />
(0.3")<br />
fl1 (0.03")<br />
5.6 (0.22")<br />
56<br />
(2.20")<br />
50 (1.97")<br />
53 (2.08")<br />
58 (2.28")<br />
28<br />
(1.10")<br />
58 (2.28")<br />
Ø1.4 (0.06")➊<br />
50 (1.97")<br />
58 (2.28")<br />
8.5 (0.34")<br />
8.5 (0.34")<br />
8.5 (0.34")<br />
9.7<br />
(0.38")<br />
56 (2.2")<br />
5.6 (0.22")<br />
8.5 (0.34")<br />
8.5 (0.34")<br />
8.5 (0.34")<br />
9.7<br />
(0.38")<br />
34.9<br />
(1.37")<br />
56 (2.20")<br />
❶ Recommended PCB drillings 1.7-2mm (0.07-0.08in).<br />
BF AND DPBF CONTACTORS WITH AC COIL<br />
BF00A control relay - DPBF09A - DPBF12A - DPBF18A definite purpose and<br />
BF09A - BF12A - BF18A - BF25A contactors four poles<br />
6.2<br />
(0.24")<br />
45 (1.77")<br />
10.9<br />
(0.43")<br />
Ø4.2 (0.17")<br />
80.7 (3.17")<br />
BF09A - BF12A - BF18A - BF25A - DPBF09A - DPBF12A - DPBF18A three poles<br />
with RF..38 thermal relay<br />
6.2<br />
(0.24")<br />
45 (1.77")<br />
10.9<br />
(0.43")<br />
Ø4.2 (0.17")<br />
7<br />
80.7 (3.17")<br />
35<br />
(1.38")<br />
BF26A - BF32A - BF38A - DPBF26A - DPBF32A three poles<br />
with RF..38 thermal relay<br />
7.9<br />
(0.31")<br />
45 (1.77")<br />
14.6<br />
(0.57")<br />
Ø4.2 (0.17")<br />
90 (3.54")<br />
BF26 T - BF32 T❶ - BF38 T - DPBF26T - DPBF32T❶ four poles<br />
61 (2.4")<br />
14.6<br />
(0.57")<br />
Ø4.2 (0.17")<br />
90 (3.54")<br />
134.8 (5.3")<br />
80 (3.14")<br />
90 (3.54")<br />
80 (3.14")<br />
90 (3.54")<br />
71 (2.79")<br />
81 (3.18")<br />
126 (4.95")<br />
71 (2.79")<br />
81 (3.18")<br />
8.5 (0.33")<br />
30<br />
(1.18")<br />
35<br />
(1.38")<br />
RF...38<br />
7.9<br />
(0.31") 14.6 (0.57")<br />
81.2 (3.19")<br />
35<br />
(1.38")<br />
RF...38<br />
35<br />
(1.38")<br />
❶ DPBF32A fitted with fourth pole BFX42.<br />
7.9<br />
(0.31") 14.6 (0.57")<br />
81.5 (3.2")<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com
electric<br />
Dimensions [mm (in)]<br />
IEC style contactors<br />
D-5<br />
BF50 00 - BF65 00 - BF80 00 - BF95 00 - BF110 00 three-poles<br />
with RF...95 3 thermal relay<br />
BF50 40 - BF65 40 - BF80 40 four poles<br />
14<br />
(0.55")<br />
75 (2.95")<br />
23.5<br />
(0.92")<br />
Ø6 (0.24")<br />
113.5 (4.47")<br />
14<br />
(0.55")<br />
98 (3.85")<br />
23.5 (0.92")<br />
Ø6 (0.24")<br />
107 (4.21")<br />
D<br />
BF CONTACTORS WITH DC COIL<br />
BF9C - BF12C - BF16C three and four poles❶<br />
with RF..25 thermal relay<br />
6.6<br />
(0.26")<br />
44 (1.73")<br />
10.3<br />
(0.40")<br />
4.2 (0.17")<br />
108 (4.25")<br />
8<br />
(0.31")<br />
BF20C - BF25C three and four poles❶<br />
with RF..25 thermal relay<br />
54 (2.12")<br />
13.7<br />
(0.54")<br />
4.2 (0.17")<br />
112.5 (4.43")<br />
110.4 (4.35")<br />
60 (2.36")<br />
75 (2.95")<br />
114 (4.49")<br />
60 (2.36")<br />
78.5 (3.09")<br />
182 (7.16")<br />
112 (4.4")<br />
124 (4.88")<br />
110 (4.33")<br />
124 (4.88")<br />
55 (2.16")<br />
78 (3.07")<br />
RF...95 3<br />
24.6<br />
(0.97")<br />
16.5 (0.65")<br />
111 (4.37")<br />
35<br />
(1.38")<br />
RF...25<br />
43.7<br />
(1.72")<br />
RF...25<br />
7.5<br />
(0.29") 12.5 (0.49")<br />
117.6 (4.63")<br />
❶ Normally, the thermal relay is mounted with three-pole types only.<br />
7.5<br />
(0.29") 12.5<br />
(0.49")<br />
119.8 (4.72")<br />
❶ Normally, the thermal relay is mounted with three-pole types only.<br />
BF20C - BF25C three and four poles❶<br />
with RF..95 1 thermal relay<br />
8<br />
(0.31")<br />
54 (2.12")<br />
13.7<br />
(0.54")<br />
4.2 (0.17")<br />
112.5 (4.43")<br />
BF32C 00 - BF40C 00 three poles<br />
with RF..25 thermal relay<br />
10.5<br />
(0.41")<br />
55 (2.16")<br />
17<br />
(0.67")<br />
4.2 (0.17")<br />
118.6 (4.67")<br />
133.5 (5.25")<br />
43.7<br />
(1.72")<br />
60 (2.36")<br />
78.5 (3.09")<br />
RF...95 1<br />
120.9 (4.76")<br />
40<br />
(1.57")<br />
75 (2.35")<br />
88 (3.46")<br />
RF...25<br />
11<br />
16.5 (0.65")<br />
125.4 (4.93")<br />
(0.43")<br />
❶ Normally, the thermal relay is mounted with three-pole types only.<br />
BF32C 00 - BF40C 00 three poles<br />
with RF..95 2 thermal relay<br />
7.5<br />
(0.29") 12.5<br />
(0.49")<br />
BF40C 40 - BF40C 22 four poles<br />
120.4 (4.73")<br />
10.5<br />
(0.41")<br />
55 (2.16")<br />
17<br />
(0.67")<br />
4.2 (0.17")<br />
118.6 (4.67")<br />
11.4<br />
(0.45")<br />
74 (2.91")<br />
17<br />
(0.67")<br />
6 (0.24")<br />
142.5 (5.6")<br />
138.4 (5.44")<br />
40<br />
(1.57")<br />
75 (2.35")<br />
88 (3.46")<br />
55 (2.16")<br />
80 (3.14")<br />
92 (3.62")<br />
RF...95 2<br />
11<br />
(0.43")<br />
16.5 (0.65")<br />
129.2 (5.08")<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com
D-6<br />
Dimensions [mm (in)]<br />
IEC style contactors<br />
electric<br />
BF50C 00 - BF65C 00 - BF80C 00 - BF95C 00 - BF110C 00 three poles<br />
with RF..95 3 relay<br />
BF65C 40 - BF80C 40 four poles<br />
D<br />
14<br />
(0.55")<br />
75 (2.95")<br />
23.5<br />
(0.92")<br />
6 (0.24")<br />
150.5 (5.92")<br />
14<br />
(0.55")<br />
98 (3.85")<br />
23.5<br />
(0.92")<br />
6 (0.24")<br />
144 (5.67")<br />
B CONTACTORS WITH AC/DC COIL<br />
B115 - B145 - B180 three poles<br />
with RF...200 thermal relay<br />
120 (4.72")<br />
40 40<br />
(1.57") (1.57")<br />
B<br />
A<br />
184 (7.23")<br />
114 (4.48") 4 (0.16")<br />
150 (5.90")<br />
170 (6.69")<br />
120 (4.72")<br />
150 (5.90")<br />
170 (6.69")<br />
182 (7.16")<br />
112 (4.4")<br />
124 (4.76")<br />
110 (4.33")<br />
124 (4.88")<br />
55 (2.16")<br />
RF...95 3<br />
78 (3.07")<br />
24.6<br />
(0.97")<br />
16.5 (0.65")<br />
149.5 (5.88")<br />
322 (12.65")<br />
M6<br />
Ø7.5 (0.29")<br />
90 (3.54")<br />
CONTACTOR TYPE A B<br />
B115 M6 15 (0.6")<br />
B145 M8 20 (0.8")<br />
B180 M8 20 (0.8")<br />
20<br />
(0.79") 40<br />
(1.57")<br />
40<br />
(1.57")<br />
M8<br />
56.5 (2.20")<br />
166.1 (6.53")<br />
B115 4 - B145 4 - B180 4 four poles<br />
40<br />
(1.57")<br />
A<br />
160 (6.29")<br />
40<br />
(1.57")<br />
B<br />
40<br />
(1.57")<br />
184 (7.23")<br />
114 (4.48") 4 (0.16")<br />
150 (5.90")<br />
170 (6.69")<br />
120 (4.72")<br />
150 (5.90")<br />
170 (6.69")<br />
CONTACTOR TYPE A B<br />
B115 M6 15 (0.6")<br />
B145 M8 20 (0.8")<br />
B180 M8 20 (0.8")<br />
Ø7.5 (0.29")<br />
M6<br />
130 (5.11")<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com
electric<br />
Dimensions [mm (in)]<br />
IEC style contactors<br />
D-7<br />
B CONTACTORS WITH AC/DC COIL<br />
B250 - B310 - B400 three poles<br />
with RF...420 thermal relay<br />
145 (5.70")<br />
47.5 47.5<br />
(1.87") (1.87")<br />
M10X35 25 (1")<br />
219.2 (8.61")<br />
144 (5.67") 5 (0.2")<br />
D<br />
180 (7.08")<br />
370 (14.54")<br />
204 (8.03")<br />
140 (5,51")<br />
179 (7.04")<br />
204 (8.03")<br />
M8<br />
Ø10 (0.39")<br />
110 (4.32")<br />
25 (1")<br />
47.5<br />
(1.87")<br />
47.5<br />
(1.87")<br />
M10<br />
56.8 (2.23")<br />
166.1 (6.53")<br />
B250 4 - B310 4 - B400 4 four poles<br />
47.5<br />
(1.87")<br />
192.5 (7.58")<br />
47.5<br />
(1.87")<br />
25 (1")<br />
47.5<br />
(1.87")<br />
219.2 (8.61")<br />
144 (5.67") 5 (0.2")<br />
180 (7.08")<br />
204 (8.03")<br />
140 (5,51")<br />
179 (7.04")<br />
204 (8.03")<br />
Ø10 (0.39")<br />
M8<br />
157.5 (6.19")<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com
D-8<br />
Dimensions [mm (in)]<br />
IEC style contactors<br />
electric<br />
B CONTACTORS WITH AC/DC COIL<br />
B500 - B630 three poles<br />
A<br />
65<br />
(2.55")<br />
192 (7.55")<br />
B<br />
65<br />
(2.55")<br />
263 (10.35")<br />
177.5 (6.99") 6 (0.23")<br />
D<br />
270 (10.6")<br />
230 (9.05")<br />
170 (6.70")<br />
230 (9.05")<br />
C<br />
Ø12 (0.47")<br />
M10<br />
150 (5.9")<br />
CONTACTOR TYPE A B C<br />
B500 M10 35 (1.38") 265 (10.43")<br />
B630 M12 40 (1.57") 270 (10.63")<br />
B500 4 - B630 4 four poles<br />
A<br />
65<br />
(2.55")<br />
B<br />
257 (10.1")<br />
65<br />
(2.55")<br />
65<br />
(2.55")<br />
263 (10.35")<br />
177.5 (6.99") 6 (0.23")<br />
270 (10.6")<br />
230 (9.05")<br />
170 (6.70")<br />
230 (9.05")<br />
C<br />
Ø12 (0.47")<br />
M10<br />
CONTACTOR TYPE A B C<br />
B500 M10 35 (1.38") 265 (10.43")<br />
B630 M12 40 (1.57") 270 (10.63")<br />
215 (8.46")<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com
electric<br />
Dimensions [mm (in)]<br />
IEC style contactors<br />
D-9<br />
B CONTACTORS WITH AC/DC COIL<br />
B630 1000 three poles<br />
60<br />
(2.36")<br />
65<br />
(2.55")<br />
194 (7.62")<br />
65<br />
(2.55")<br />
M12<br />
147.2 (5.78")<br />
263 (10.35")<br />
207.6 (8.16")<br />
D<br />
476 (18.74")<br />
230 (9.05")<br />
270 (10.63")<br />
170 (6.70")<br />
230 (9.05")<br />
Ø12 (0.47")<br />
150 (5.9")<br />
B630 1000 four poles<br />
60<br />
(2.36")<br />
65<br />
(2.55")<br />
259 (10.18")<br />
65<br />
(2.55")<br />
65<br />
(2.55")<br />
M12<br />
263 (10.35")<br />
207.6 (8.16")<br />
147.2 (5.78")<br />
476 (18.74")<br />
230 (9.05")<br />
270 (10.63")<br />
170 (6.70")<br />
230 (9.05")<br />
Ø12 (0.47")<br />
215 (8.45")<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com
D-10<br />
Dimensions [mm (in)]<br />
IEC style contactors<br />
electric<br />
B CONTACTORS WITH AC COIL<br />
B1250 - B1600 three poles<br />
D<br />
80 (3.15")<br />
40<br />
(1.57")<br />
540 (21.25")<br />
500 (16.69")<br />
130 (5.12")<br />
M1<br />
288 (11.34")<br />
10 (0.39")<br />
360 (14.17")<br />
320 (12.6")<br />
Ø12 (0.47")<br />
B1250 - B1600 four poles<br />
670 (26.33")<br />
630 (24.76")<br />
80 (3.15")<br />
40<br />
130 (5.12")<br />
(1.57") M1<br />
288 (11.34")<br />
10 (0.39")<br />
360 (14.17")<br />
320 (12.6")<br />
Ø12 (0.47")<br />
B115 - B145 - B180 - B250 - B310 - B400 - B500 - B630 - B630 1000 - B1250 - B1600<br />
10 (0.39")<br />
Minimum safety distance<br />
from metal parts.<br />
Minimum space needed to replace the coil.<br />
A<br />
B115-B145-B180 B250-B310-B400 B500-B630 1000<br />
A 120 (4.7”) 145 (5.7”) 170 (6.69”)<br />
B 100 (3.9”) 110 (4.3”) 160 (6.29”)<br />
B<br />
If dimension B is respected, coil replacement is<br />
possible without removing power wiring.<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com
electric<br />
Dimensions [mm (in)]<br />
IEC style contactors<br />
D-11<br />
CONTACTORS FOR POWER FACTOR CORRECTION<br />
BFK09 10A - BFK12 10A - BFK18 10A<br />
BFK26 00A - BFK32 00A - BFK38 00A<br />
6.2<br />
(0.24")<br />
10.9 (0.43")<br />
Ø4.2 (0.17")<br />
116.6 (4.58")<br />
7.9<br />
(0.31")<br />
14.6 (0.57")<br />
Ø4.2 (0.17")<br />
125.5 (4.93")<br />
D<br />
81 (3.19")<br />
71 (2.79")<br />
113.5 (4.46")<br />
90 (3.54")<br />
80 (3.14")<br />
123.2 (4.84")<br />
45 (1.77")<br />
35<br />
(1.38")<br />
45 (1.77")<br />
35<br />
(1.38")<br />
BF50K 00 - BF65K 00 - BF70K 00 - BF80K 00<br />
13.9<br />
(0.55")<br />
23.5<br />
(0.92")<br />
Ø6 (0.24")<br />
148.3 (5.83")<br />
124 (4.87")<br />
112 (4.4")<br />
185 (7.27")<br />
55 (2.16")<br />
75 (2.95")<br />
ADD-ON BLOCKS WITH BG MINI-CONTACTORS<br />
BGX10 auxiliary contacts ❶<br />
BGX50 00 interlock with BGX10 or BGXF auxiliary contacts<br />
and BGX77 or BGX78 or BGX79 suppressor<br />
BGX77 or BGX78 or BGX79<br />
suppressor only<br />
58 (2.28")<br />
44 (1.73")<br />
82 (3.23")<br />
26<br />
(1.02")<br />
30<br />
(1.18")<br />
58 (2.28")<br />
88 (3.46")<br />
88 (3.46")<br />
6 (0.24")<br />
26<br />
(1.02")<br />
30<br />
(1.18")<br />
58 (2.28")<br />
44 (1.73")<br />
56 (2.20")<br />
26<br />
(1.02")<br />
23.8<br />
(0.94")<br />
❶ Valid for BGX11... contacts as well when mounted on<br />
left-hand contactor of BGT or BGC assembly.<br />
BGX50 00<br />
BGX10 - BGX77<br />
BGX78 - BGX79<br />
BGXF10<br />
7.75 (0.31")<br />
BGX77 - BGX78<br />
BGX79<br />
Paralleling links G323 - G324<br />
G325 - G326<br />
BGX80 00 shroud<br />
21<br />
(0.83")<br />
10<br />
(0.39")<br />
37<br />
(1.45")<br />
G323<br />
15<br />
(0.59")<br />
10<br />
(0.39") G324<br />
12<br />
(0.47")<br />
23.5<br />
(0.92")<br />
12<br />
(0.47")<br />
37<br />
(1.45")<br />
G325<br />
9<br />
(0.35")<br />
16<br />
(0.63")<br />
G326<br />
12<br />
(0.47")<br />
58 (2.28")<br />
44 (1.73") 59 (2.32")<br />
48.5 (1.91")<br />
BGX80 00<br />
ADD-ON BLOCKS WITH BF CONTACTORS<br />
Auxiliary contacts BFX10<br />
❶<br />
21.4<br />
(0.84")<br />
28.9<br />
(1.14")<br />
G484<br />
28.2<br />
(1.11")<br />
36<br />
(1.42")<br />
G418<br />
8<br />
(0.31")<br />
28<br />
(1.1")<br />
41.4<br />
(1.63")<br />
40.6<br />
(1.6")<br />
46<br />
(1.6")<br />
❶ BFX10 add-on blocks with four contacts are 42.8mm wide.<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com
D-12<br />
Dimensions [mm (in)]<br />
IEC style contactors<br />
electric<br />
ADD-ON BLOCKS WITH BF CONTACTORS<br />
G218<br />
G481, G482<br />
G280 adapter with G218 contact<br />
D<br />
8 (0.31")<br />
27<br />
(1.06")<br />
46.9<br />
(1.85")<br />
8 (0.31")<br />
36<br />
(1.42")<br />
43<br />
(1.69")<br />
9.5 (0.37") 52.5 (2.07")<br />
10.3<br />
(0.41")<br />
44.2<br />
(1.74")<br />
G419 adapter c/w G418 contacts, G428 contacts<br />
G483 adapter c/w G481 or G482 contacts<br />
9.5 (0.37") 57 (2.24")<br />
12.3<br />
(0.48")<br />
G485, G486, G487 delayed contacts<br />
28<br />
(1,1")<br />
45.7 (1.8")<br />
BFX50 00, BFX50 01 interlocks<br />
10 (0.39")<br />
51 (2.01")<br />
44.7<br />
(1.76")<br />
BFX50 03, G269 1, G269 2 interlocks<br />
15 (0.59")<br />
31.9<br />
(1.25")<br />
G222, G272 latch<br />
45 (1.77")<br />
29.1<br />
(1.15")<br />
G454, G455 manual closing<br />
35<br />
(1.38")<br />
20<br />
(0.79")<br />
32.1<br />
(1.26")<br />
41 (1.61")<br />
40 (1.57")<br />
38.7<br />
(1.52")<br />
G318, G319 225, G322 suppressors<br />
G231 terminal<br />
10 (0.39")<br />
33.5<br />
(1.32")<br />
G232 terminal<br />
12 (0.47")<br />
34.5<br />
(1.36")<br />
8 (0.31")<br />
16.5<br />
(0.65")<br />
23 (0.91")<br />
41 (1.61")<br />
13.6 (0.53")<br />
16 (0.63")<br />
17<br />
(0.67")<br />
G281 terminal<br />
53 (2.09") 46 (1.81")<br />
31.3<br />
(1.24")<br />
G271, G288 terminal<br />
66.5 (2.62") ❶<br />
24.8<br />
(0.98")<br />
49 (1.93")<br />
28.9<br />
(1.14")<br />
G285 auxiliary terminal<br />
11.5 (0.45")<br />
17.1<br />
(0.67")<br />
25<br />
(0.98")<br />
11.3 (0.44")<br />
21 (0.83")<br />
❶ For G288 terminal, 90mm (3.54in) dimension.<br />
Universal base BFX89 01<br />
Brackets BFX89 02<br />
75 (2.95")<br />
45 (1.77")<br />
45 (1.77")<br />
Ø4.3<br />
(0.17")<br />
31.8 (1.25")<br />
11.6 (0.46")<br />
86 (3.39")<br />
14.5 (0.57")<br />
R2.1<br />
(R0.08")<br />
21<br />
(0.83")<br />
16 (0.63")<br />
10<br />
(0.39")<br />
9.7<br />
(0.38")<br />
35<br />
(1.38")<br />
Ø4.3<br />
(0.17")<br />
Ø3.5 (0.14")<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com
electric<br />
Dimensions [mm (in)]<br />
IEC style contactors<br />
D-13<br />
ADD-ON BLOCKS WITH B CONTACTORS<br />
G350, G350, G354 G354<br />
G350, G354 auxiliary contacts<br />
14.5 (0.57")<br />
111.5 (4.39")<br />
G355 G355 interlock<br />
15 (0.59")<br />
60.6 (2.39")<br />
D<br />
G356...<br />
G356 interlocks<br />
29.8<br />
(1.17")<br />
G358 G358<br />
G358 adapter<br />
30<br />
(1.18")<br />
➊<br />
G360, G361 G360, G361<br />
❶ For interaxes dimensions, refer to page TC-28.<br />
Terminal protection G360, G361<br />
31.9<br />
(1.26")<br />
102 (4.01") 50 (1.97")<br />
G363<br />
G363<br />
G363<br />
35.2<br />
(1.38")<br />
127.5 (5.02") 56.5 (2.22")<br />
68 (2.68")<br />
96.7 (3.81")<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com
D-14<br />
G527, G529<br />
G527, G529 terminal protection<br />
Dimensions [mm (in)]<br />
IEC style contactors<br />
electric<br />
185 (7.28") 167 (6.57") 83 (3.27")<br />
D<br />
117 (4.6")<br />
G528, G530<br />
G528, G530 terminal protection<br />
250 (9.84")<br />
167 (6.57") 83 (3.27")<br />
117 (4.6")<br />
11 BA1594<br />
11 BA1594<br />
BA1594, BA1720, BA1845 2-pole bar<br />
B 5 (0.2")<br />
A<br />
BAR TYPE A B C<br />
BA1594 45 (1.77") 32 (1.26") Ø14 (0.55")<br />
BA1720 53 (2.09") 50 (1.97") Ø18 (0.71")<br />
BA1845 65 (2.51") 80 (3.15") Ø13 (0.51")<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com
electric<br />
Dimensions [mm (in)]<br />
IEC style overload relays<br />
D-15<br />
RFX38 04 base c/w RF...38 thermal relay<br />
7.9<br />
(0.31")<br />
45 (1.77")<br />
14.6<br />
(0.57")<br />
70.3 (2.77")<br />
34<br />
(1.34")<br />
Ø4.2 (0.17")<br />
73.5 (2.89")<br />
88.4 (3.48")<br />
83 (3.27")<br />
D<br />
7.9<br />
(0.31")<br />
14.6<br />
(0.57")<br />
G230 base c/w RF...25 thermal relay<br />
G270 base c/w RF...95 thermal relay<br />
5.5<br />
(0.22")<br />
44 (1.73")<br />
12.8<br />
35<br />
(1.38")<br />
Ø4.2 (0.17")<br />
93.1 (3.67")<br />
84 (3.3")<br />
9.7<br />
(0.38")<br />
55 (2.16")<br />
16.5<br />
(0.65")<br />
43 (1.69")<br />
Ø4.2 (0.17")<br />
102 (4.02")❶<br />
95.4 (3.76")<br />
7.5<br />
(0.31")<br />
12.6<br />
(0.5")<br />
79 (3.11")<br />
85 (3.35")<br />
11<br />
(0.43")<br />
16.5<br />
(0.65")<br />
RF...200 thermal relay with G372 links<br />
23.8<br />
(0.94")<br />
127.5 (5.02") 40<br />
166.1 (6.54")<br />
40<br />
(1.57")<br />
122 (4.8")<br />
(1.57")<br />
Ø5.4<br />
(0.21")<br />
113.4 (4.46")<br />
51 (2")<br />
74 (2.91")<br />
172 (6.77")<br />
38.6<br />
(1.52")<br />
61 (2.4")<br />
20 (0.79")<br />
40<br />
(1.57")<br />
40<br />
(1.57")<br />
M8<br />
56.5 (2.22")<br />
RF...420 thermal relay with G376 links<br />
25<br />
(0.98")<br />
145 (5.71")<br />
47.5 (1.87")<br />
47.5 (1.87")<br />
165.4 (6.51")<br />
153.3 (6.04")<br />
Ø5.4<br />
(0.21")<br />
121.2 (4.77")<br />
74 (2.91")<br />
189.6 (7.46")<br />
44.8 (1.76")<br />
25<br />
(0.98")<br />
47.5 (1.87") 47.5 (1.87")<br />
M10<br />
56.8 (2.24")<br />
ADD-ON BLOCKS FOR THERMAL OVERLOAD RELAYS<br />
G228 reset<br />
G244 button<br />
63 (2.48")<br />
19<br />
(0.75")<br />
89.7 (3.53")<br />
13.3<br />
(0.52")<br />
54.5 (2.15")<br />
10<br />
(0.39")<br />
35.8<br />
(1.41")<br />
35.8<br />
(1.41")<br />
26.7<br />
(1.05")<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com
D-16<br />
Dimensions [mm (in)]<br />
IEC style starters<br />
electric<br />
FULL VOLTAGE STARTERS - EMPTY ENCLOSURES<br />
M0<br />
M1<br />
D<br />
88 (3.46")<br />
44 (1.73") fl4.5 (0.18")<br />
140 (5.51")<br />
133.3 (5.26")<br />
119.5 (4.7")<br />
88 (3.46")<br />
44 (1.73")<br />
fl4.5 (0.18")<br />
155.3 (6.11")<br />
148.3 (5.84")<br />
134.5 (5.3")<br />
184 (7.24")<br />
175 (6.89")<br />
49 (1.93")<br />
19.4<br />
(0.74")<br />
202 (7.95")<br />
193 (7.6")<br />
49 (1.93")<br />
19.4<br />
(0.74")<br />
PG13.5 / M20 knockout<br />
PG13.5 / M20 knockout<br />
M2<br />
110 (.33")<br />
55 (2.17")<br />
Ø4.5 (0.18")<br />
169 (6.65")<br />
162.3 (6.39")<br />
148.5 (5.85")<br />
234 (9.21")<br />
225 (8.86")<br />
60 (2.36")<br />
22.8<br />
(0.9")<br />
PG16 / M25 knockout<br />
PG13.5 / M20 knockout<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com
electric<br />
Dimensions [mm (in)]<br />
IEC style starters<br />
D-17<br />
FULL VOLTAGE STARTERS - EMPTY ENCLOSURES<br />
M3<br />
220 (8.66")<br />
190,8 (7.51")<br />
170 (6.69")<br />
D<br />
280 (11.02")<br />
60 (2.36")<br />
31.4<br />
(1.24")<br />
Ø37 (1.45") knockout<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com
D-18<br />
Dimensions [mm (in)]<br />
IEC style starters<br />
electric<br />
REVERSING CONTACTOR ASSEMBLIES<br />
BGR with external interlock and wiring<br />
D<br />
58 (2.28")<br />
88 (3.46")<br />
4.4 4.4 (0.17")<br />
(0.17")<br />
Ø4 (0.16")<br />
50 (1.97")<br />
6 (0.24")<br />
8.5 (0.33")<br />
8.5 (0.33")<br />
8.5 (0.33")<br />
9.7 (0.38")<br />
34.9<br />
(1.37")<br />
56 (2.2")<br />
BGU with external interlock<br />
88 (3.46")<br />
4.4 4.4 (0.17")<br />
(0.17")<br />
Ø4 (0.16")<br />
6 (0.24")<br />
58 (2.28")<br />
50 (1.97")<br />
8.5 (0.33")<br />
8.5 (0.33")<br />
8.5 (0.33")<br />
9.7 (0.38")<br />
34.9<br />
(1.37")<br />
56 (2.2")<br />
BF0...A with external interlock<br />
90 (3.54")<br />
Ø4.2 (0.17")<br />
90 (3.54")<br />
83 (3.77")<br />
71 (2.79")<br />
35<br />
(1.38")<br />
BFU9C - BFU12C - BFU16C<br />
6.6<br />
(0.26")<br />
88 (3.46")<br />
10.3 (0.40")<br />
Ø4.2 (0.16")<br />
108 (4.25")<br />
75 (2.95")<br />
60 (2.36")<br />
35<br />
(1.38")<br />
35<br />
(1.38")<br />
BFU20C - BFU25C<br />
8<br />
(0.31")<br />
108 (4.25")<br />
13.7 (0.53")<br />
Ø4.2 (0.16")<br />
112.5 (4.43")<br />
75 (2.95")<br />
60 (2.36")<br />
43.7 (1.72")<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com
electric<br />
Dimensions [mm (in)]<br />
Push buttons and pilot devices, 22mm<br />
D-19<br />
Flush push-button with auxiliary<br />
contacts or lamp-holder (direct or<br />
resistor-diode type)<br />
Ø29.8<br />
(1.17")<br />
Flush push-button with faston auxiliary<br />
contacts<br />
Ø29.8<br />
(1.17")<br />
Drillings - Minimum<br />
recommended distances<br />
50 (1.97")<br />
Push-buttons<br />
Ø29.8<br />
(1.17")<br />
Ø29.8<br />
(1.17")<br />
1-6 (0.03"-0.23") max<br />
10<br />
(0.39")<br />
30<br />
(1.18")<br />
n 1 LM2T<br />
n 1 LP2T<br />
n 1 LM2T<br />
n 1 LM2T<br />
n 1 LM2T<br />
AU120<br />
AU120<br />
ADD-ON<br />
ELEMENTS<br />
C..<br />
VL230<br />
DL400<br />
42.4 (1.67")<br />
20.3<br />
(0.78")<br />
13.8<br />
(0.54")<br />
43 (1.69")<br />
22.7<br />
(0.89")<br />
n 1 LM2T<br />
n 1 LP2T<br />
n 1 LM2T<br />
AU120<br />
AU120<br />
CF..<br />
ADD-ON<br />
ELEMENTS<br />
42.4 (1.67")<br />
63.5 (2.50")<br />
20.3<br />
(0.78")<br />
22.7<br />
(0.89")<br />
43 (1.69") 13.8<br />
(0.54")<br />
42.4 (1.67")<br />
22.5<br />
(0.88")<br />
30 (1.18")<br />
65 (2.56")<br />
❶<br />
20.9<br />
(0.82")<br />
Extended<br />
L...2T B2...<br />
Push-push<br />
L...2T Q2...<br />
Illuminated extended<br />
L...2T BL2...<br />
Illuminated push-push<br />
L...2T QL2...<br />
20.5<br />
(0.80")<br />
Guarded<br />
L...2T B30...<br />
Illuminated flush<br />
L...2T BL10...<br />
Illuminated push-push<br />
L...2T QL10...<br />
D<br />
❶ When faston auxiliary contacts are<br />
used, the vertical pitch must be<br />
90mm (3.54”) minimum.<br />
Mushroom-head buttons<br />
Ø40 (1.57")<br />
28.5<br />
(1.12")<br />
Ø60 (2.36")<br />
29.2<br />
(1.15")<br />
Ø40 (1.57")<br />
29<br />
(1.14")<br />
Ø40 (1.57")<br />
49.3 (1.94")<br />
Ø40 (1.57")<br />
32.6 (1.28")<br />
Ø40 (1.57")<br />
24.2<br />
(0.95")<br />
33.8<br />
(1.33")<br />
Ø40 (1.57")<br />
49 (1.93")<br />
Spring return<br />
L...2T B614...<br />
Illuminated spring return<br />
L...2T BL614...<br />
Spring return<br />
L...2T B616...<br />
Push-pull<br />
L...2T B624...<br />
Illuminated<br />
Push-pull<br />
LM2T BL624...<br />
Turn to release<br />
L...2T B634...<br />
Turn key to release<br />
L...2T B654...<br />
Turn to release<br />
EN418 compliant<br />
L...2T B6644<br />
Reset button<br />
(complete unit)<br />
Ø29.8<br />
(1.17")<br />
19.1<br />
(0.75")<br />
42.4 (1.67")<br />
L...2T R1...<br />
13.8<br />
(0.54")<br />
140 (5.51") max<br />
Double-touch push buttons<br />
with or without indicator<br />
2 flush buttons<br />
54 (2.13")<br />
28 (1.10")<br />
O<br />
12<br />
(0.47")<br />
L...2T B71... - L...2T BL71...<br />
Potentiometer drive<br />
Ø29.8<br />
(1.17")<br />
42.4 (1.67")<br />
35.7 (1.40")<br />
56.8 (2.23")<br />
LM2T P100 - LM2T P110<br />
Double-touch push buttons<br />
with or without indicator<br />
1 flush and 1 extended buttons<br />
54 (2.13")<br />
28 (1.10")<br />
O<br />
15<br />
(0.59")<br />
L...2T B72... - L...2T BL72...<br />
Selectors<br />
Ø29.8<br />
(1.17")<br />
Knob<br />
L...2T S1...<br />
Illuminated knob<br />
L...2T SL1...<br />
27.5<br />
(1.08")<br />
Triple-touch buttons<br />
2 external flush and middle<br />
extended buttons<br />
54 (2.13")<br />
28 (1.10")<br />
I<br />
STOP<br />
I<br />
L...2T B73...<br />
12<br />
(0.47")<br />
6<br />
Ø39.4 (1.55")<br />
Lever<br />
L...2T S2...<br />
27.5<br />
(1.08")<br />
Transformer or flashing<br />
lamp holder<br />
50 (1.97")<br />
25.1<br />
(0.99")<br />
Ø29.8<br />
(1.17")<br />
Key<br />
L...2T S3...<br />
42.4 (1.67")<br />
LM2T YL... - LM2T GL...<br />
LM2T XL... - LM2T FL...<br />
23.8<br />
(0.93")<br />
27.5<br />
(1.08")<br />
LED integrated lamp-holder<br />
steady or flashing light<br />
1-6 (0.03"-0.23") max<br />
10<br />
(0.39")<br />
30 (1.18")<br />
57 (2.24")<br />
LM2T L... - LM2T M...<br />
20.2<br />
(0.79")<br />
42.4 (1.67")<br />
20.3<br />
(0.78")<br />
43 (1.69")<br />
Pilot light head<br />
Ø29.8<br />
(1.17")<br />
LM2T IL1...<br />
16.2<br />
(0.64")<br />
LED-integrated<br />
monoblock pilot light<br />
steady light<br />
1-6 (0.03"-0.23") max<br />
Ø29.5<br />
(1.17")<br />
LP2T ILA...<br />
LP2T ILB...<br />
LP2T ILE...<br />
LP2T ILM...<br />
38.4 (1.51") 14.3<br />
(0.56")<br />
Monoblock pilot light<br />
complete with diffuser,<br />
without terminal<br />
protection<br />
1-6 (0.03"-0.23") max<br />
Ø29.6<br />
(1.16")<br />
LP2T IL21...<br />
16.5<br />
(0.65")<br />
42 (1.65")<br />
Monoblock pilot light<br />
complete with diffuser<br />
and terminal<br />
protection<br />
1-6 (0.03"-0.23") max<br />
Ø29.6<br />
(1.16")<br />
LP2T IL22...<br />
16.6<br />
(0.65")<br />
43 (1.69")<br />
Monoblock pilot light<br />
complete with diffuser,<br />
1-6.35 (0.25”) or 2-2.8 (0.11”)<br />
Faston terminals without<br />
terminal protection<br />
1-6 (0.03"-0.23") max<br />
Ø29.6<br />
(1.16")<br />
LP2T IL23...<br />
16.5<br />
(0.65")<br />
42 (1.65")<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com
D-20<br />
Dimensions [mm (in)]<br />
Push buttons and pilot devices, 22mm<br />
electric<br />
D<br />
Transparent boot<br />
Ø44 (1.73")<br />
35<br />
(1.38")<br />
LM2T AU167<br />
Button protection boot<br />
25<br />
(0.98")<br />
Ø33.4<br />
(1.31")<br />
18.1<br />
(0.71")<br />
LM2T AU14... LM2T AU13...<br />
Ø33.4<br />
(1.31")<br />
Double/triple button boot<br />
55 (2.16")<br />
30<br />
(1.18")<br />
LM2T A157<br />
20.4<br />
(0.8")<br />
Threaded plug for<br />
unused holes<br />
21.3<br />
(0.84")<br />
Ø30<br />
(1.18")<br />
LM2T A130<br />
Knob selector protection<br />
36<br />
(1.42")<br />
27.5<br />
(1.08")<br />
Label holder<br />
48 (1.89")<br />
Label<br />
15.1<br />
(0.59")<br />
27<br />
(1.08")<br />
LM2T AU10...<br />
Label holder<br />
12.4 (0.49")<br />
27.8<br />
(1.09")<br />
45.6 (1.80")<br />
Label<br />
12.2 (0.48")<br />
27.5<br />
(1.08")<br />
LM2T A...<br />
Plastic disk for mushroomhead<br />
push-buttons<br />
A<br />
Ø22.5<br />
(0.89")<br />
EMERGENCY<br />
8 LM2T AU185<br />
29.8<br />
(1.17")<br />
(2x2mm (0.08x0.08”) tab)<br />
LM2T AU105<br />
29.8<br />
(1.17")<br />
Joystick with free actuation lever<br />
Ø29.5<br />
(1.16")<br />
Joystick with mechanical latch lever<br />
Ø29.5<br />
(1.16")<br />
Control station for one operator<br />
72 (2.83")<br />
54 (2.13") 65 (2.56")<br />
LM2T J21... - LM2T J41...<br />
Complete push button station with one actuator<br />
42.5 (1.67")<br />
49 (1.93")<br />
85 (3.35")<br />
40 (1.57")<br />
40 (1.57")<br />
40 (1.57")<br />
40 (1.57")<br />
22.3<br />
(0.88")<br />
29.9<br />
(1.18")<br />
33.5 (1.32")<br />
33 (1.30")<br />
24.2<br />
(0.95")<br />
49 (1.93")<br />
L2PP 1A5 - L2PP 1A8<br />
(2x2mm (0.08x0.08”) tab)<br />
L2PP 100<br />
L2PP 150<br />
L2PP 110<br />
L2PP 115<br />
L2PP 160<br />
L2PP 165<br />
L2PP 120<br />
L2PP 170<br />
L2PP 130<br />
L2PP 180<br />
Control station for two actuators<br />
72 (2.83")<br />
54 (2.13")<br />
65 (2.56")<br />
34.5 (1.35")<br />
81 (3.19")<br />
117 (4.61")<br />
41.5 (1.63")<br />
70.5 (2.78")<br />
70.5 (2.78")<br />
(2x1mm (0.08x0.04”) tab)<br />
LM2T AU100<br />
STOP<br />
LM2T AU11...<br />
1.5 (0.05")<br />
1-6 (0.03"-0.23") max<br />
(2x2mm (0.08x0.08”) tab)<br />
A = 60mm<br />
A = 90mm<br />
LM2T J20<br />
For<br />
8LM2T J40 only<br />
20<br />
(0.79")<br />
43 (1.69")<br />
22.7<br />
(0.89")<br />
1.5 (0.05")<br />
1-6 (0.03"-0.23") max<br />
LM2T J20<br />
For<br />
8LM2T J40 only<br />
20<br />
(0.79")<br />
43 (1.69")<br />
22.7<br />
(0.89")<br />
10<br />
(0.39")<br />
30 (1.18")<br />
LM2T J20... - LM2T J40...<br />
42.4 (1.66")<br />
10<br />
(0.39")<br />
30 (1.18")<br />
42.4 (1.66")<br />
22.3<br />
(0.88")<br />
L2PP 2A8 (2x2mm (0.08x0.08”) tab)<br />
For 3, 4 or 5 actuator versions, increase the total length by the<br />
pitch between the drillings, 35mm (1.38”) for each extra operator.<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com
electric<br />
Dimensions [mm (in)]<br />
Limit switches, K series<br />
D-21<br />
KB A1<br />
KM A1<br />
Ø4.3<br />
(0.16")<br />
22<br />
(0.86")<br />
20<br />
(0.78")<br />
30<br />
(1.18")<br />
54.5 (2.14")<br />
20<br />
(0.78")<br />
12.5<br />
(0.49")<br />
30<br />
(1.18")<br />
1/2 NPT<br />
KC A1<br />
KN A1<br />
Ø4.3<br />
(0.16")<br />
1/2 NPT<br />
22(0.86")<br />
20 (0.78")<br />
42 (1.65")<br />
40(1.57")<br />
50 (1.97")<br />
60 (2.36")<br />
20<br />
(0.78")<br />
44 (1.73")<br />
12.5<br />
(0.49")<br />
30<br />
(1.18")<br />
KB B1 - KB B2<br />
KM B1 - KM B2<br />
Ø11<br />
(0.43")<br />
Ø4.3<br />
(0.16")<br />
22<br />
(0.86")<br />
20<br />
(0.78")<br />
30<br />
(1.18")<br />
54.5 (2.14")<br />
30.5<br />
(1.20")<br />
12.5<br />
(0.49")<br />
30<br />
(1.18")<br />
1/2 NPT<br />
KC B1 - KC B2<br />
KN B1 - KN B2<br />
Ø4.3<br />
(0.16")<br />
1/2 NPT<br />
Ø11<br />
(0.43")<br />
22(0.86")<br />
20 (0.78")<br />
42 (1.65")<br />
40(1.57")<br />
50 (1.97")<br />
60 (2.36")<br />
30.5<br />
(1.20")<br />
44 (1.73")<br />
12.5<br />
(0.49")<br />
30<br />
(1.18")<br />
D<br />
KB C1 - KB C2<br />
KM C1 - KM C2<br />
Ø14<br />
Ø4.3<br />
(0.16")<br />
22<br />
(0.86")<br />
20<br />
(0.78")<br />
30<br />
(1.18")<br />
39<br />
(1.53")<br />
54.5 (2.14")<br />
12.5<br />
(0.49")<br />
30<br />
(1.18")<br />
1/2 NPT<br />
KC C1 - KC C2<br />
KN C1 - KN C2<br />
Ø4.3<br />
(0.16")<br />
1/2 NPT<br />
Ø14<br />
(0.55")<br />
22(0.86")<br />
20 (0.78")<br />
42 (1.65")<br />
40(1.57")<br />
50 (1.97")<br />
60 (2.36")<br />
33<br />
(1.30")<br />
44 (1.73")<br />
12.5<br />
(0.49")<br />
30<br />
(1.18")<br />
KB D1 - KB D2<br />
KM D1 - KM D2<br />
Ø4.3<br />
(0.16")<br />
Ø14<br />
(0.55")<br />
22<br />
(0.86")<br />
20<br />
(0.78")<br />
30<br />
(1.18")<br />
54.5 (2.14") 41<br />
(1.61")<br />
12.5<br />
(0.49")<br />
30<br />
(1.18")<br />
1/2 NPT<br />
KC D1 - KC D2<br />
KN D1 - KN D2<br />
Ø4.3<br />
(0.16")<br />
1/2 NPT<br />
Ø14<br />
(0.55")<br />
22(0.86")<br />
20 (0.78")<br />
42 (1.65")<br />
40(1.57")<br />
50 (1.97")<br />
60 (2.36")<br />
44 (1.73") 41 (1.61")<br />
12.5<br />
(0.49")<br />
30<br />
(1.18")<br />
KB E1 - KB E2<br />
KM E1 - KM E2<br />
Ø19<br />
(0.74")<br />
Ø4.3<br />
(0.16")<br />
22<br />
(0.86")<br />
20<br />
(0.78")<br />
30<br />
(1.18")<br />
54.5 (2.14") 54 (2.12")<br />
40 (1.57")<br />
30<br />
(1.18")<br />
1/2 NPT<br />
KC E1 - KC E2<br />
KN E1 - KN E2<br />
Ø4.3<br />
(0.16")<br />
1/2 NPT<br />
Ø19<br />
(0.74")<br />
22(0.86")<br />
20 (0.78")<br />
42 (1.65")<br />
40(1.57")<br />
50 (1.97")<br />
60 (2.36")<br />
54 (2.12")<br />
44 (1.73")<br />
40 (1.57")<br />
30<br />
(1.18")<br />
KB E3<br />
KM E3<br />
Ø50x10<br />
(1.97"x0.39")<br />
Ø4.3<br />
(0.16")<br />
22<br />
(0.86")<br />
20<br />
(0.78")<br />
30<br />
(1.18")<br />
54.5 (2.14")<br />
69.5 (2.73")<br />
42.5 (1.67")<br />
30<br />
(1.18")<br />
1/2 NPT<br />
KC E3<br />
KN E3<br />
Ø50x10<br />
(1.97"x0.39")<br />
Ø4.3<br />
(0.16")<br />
1/2 NPT<br />
22(0.86")<br />
20 (0.78")<br />
42 (1.65")<br />
40(1.57")<br />
50 (1.97")<br />
60 (2.36")<br />
69.5 (2.73")<br />
44 (1.73")<br />
41.5 (1.63")<br />
30<br />
(1.18")<br />
KB F1 - KB F2<br />
KM F1 - KM F<br />
KC F1 - KC F2<br />
KN F1 - KN F2<br />
KB F3<br />
KM F3<br />
42.5 (1.67")<br />
KC F3<br />
KN F3<br />
Ø4.3<br />
(0.16")<br />
22<br />
(0.86")<br />
20<br />
(0.78")<br />
30<br />
(1.18")<br />
68 - 111 (2.67"-4.37")<br />
54.5 (2.14")<br />
40 (1.57")<br />
30<br />
(1.18")<br />
1/2 NPT<br />
22(0.86")<br />
20 (0.78")<br />
Ø4.3<br />
(0.16")<br />
1/2 NPT<br />
42 (1.65")<br />
40(1.57")<br />
50 (1.97")<br />
60 (2.36")<br />
66-110 (2.60"x4.33")<br />
44 (1.73")<br />
40 (1.57")<br />
30<br />
(1.18")<br />
Ø50x10<br />
(1.97"x0.39")<br />
Ø4.3<br />
(0.16")<br />
22<br />
(0.86")<br />
20<br />
(0.78")<br />
30<br />
(1.18")<br />
54.5 (2.14")<br />
84 - 127 (3.30"- 5")<br />
30<br />
(1.18")<br />
1/2 NPT<br />
Ø50x10<br />
(1.97"x0.39")<br />
22(0.86")<br />
20 (0.78")<br />
Ø4.3<br />
(0.16")<br />
1/2 NPT<br />
42 (1.65")<br />
40(1.57")<br />
50 (1.97")<br />
60 (2.36")<br />
81-125 (3.19"-4.92")<br />
44 (1.73")<br />
42.5 (1.67")<br />
30<br />
(1.18")<br />
KB F4<br />
KM F4<br />
51.5-66.5 (2.02"-2.61")<br />
KC F4<br />
KN F4<br />
KB H1<br />
KM H1<br />
KC H1<br />
KN H1<br />
Ø50x10<br />
(1.97"x0.39")<br />
Ø4.3<br />
(0.16")<br />
22<br />
(0.86")<br />
20<br />
(0.78")<br />
30<br />
(1.18")<br />
84 - 127 (3.30"- 5")<br />
54.5 (2.14")<br />
30<br />
(1.18")<br />
1/2 NPT<br />
Ø50x10<br />
(1.97"x0.39")<br />
22(0.86")<br />
20 (0.78")<br />
Ø4.3<br />
(0.16")<br />
1/2 NPT<br />
42 (1.65")<br />
40(1.57")<br />
50 (1.97")<br />
60 (2.36")<br />
81-125 (3.19"-4.92")<br />
44 (1.73")<br />
51.5-66.5 (2.02"-2.61")<br />
30<br />
(1.18")<br />
Ø4.3<br />
(0.16")<br />
50 (1.97")<br />
22<br />
(0.86")<br />
20<br />
(0.78")<br />
30<br />
(1.18")<br />
94 (3.7")<br />
54.5 (2.14")<br />
Ø10<br />
(0.39")<br />
26<br />
(1.02")<br />
30<br />
(1.18")<br />
1/2 NPT<br />
50 (1.96")<br />
Ø4.3<br />
(0.16") 22(0.86")<br />
20 (0.78")<br />
42 (1.65")<br />
1/2 NPT 40(1.57")<br />
50 (1.97")<br />
60 (2.36")<br />
94 (3.70")<br />
44 (1.73")<br />
Ø10<br />
(0.39")<br />
26<br />
(1.02")<br />
30<br />
(1.18")<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com
D-22<br />
Dimensions [mm (in)]<br />
Limit switches, K series.<br />
electric<br />
KB L1 - KB L2<br />
KM L1 - KM L2<br />
KC L1 - KC L2<br />
KN L1 - KN L2<br />
KB M1 - KB M2<br />
KM M1 - KM M2<br />
KC M1 - KC M2<br />
KN M1 - KN M2<br />
D<br />
32-208 (1.26"-8.19")<br />
33.6<br />
(1.32")<br />
32-208 (1.26"-8.19")<br />
33.6<br />
(1.32")<br />
Ø6<br />
(0.24")<br />
140 (5.51")<br />
12<br />
(0.49")<br />
Ø6<br />
(0.23") 12.5<br />
(0.49")<br />
140 (5.51")<br />
Ø4.3<br />
(0.16")<br />
22<br />
(0.86")<br />
20<br />
(0.78")<br />
30<br />
(1.18")<br />
54.5 (2.14")<br />
30<br />
(1.18")<br />
1/2 NPT<br />
Ø4.3<br />
(0.16")<br />
1/2 NPT<br />
22(0.86")<br />
20 (0.78")<br />
42 (1.65")<br />
40(1.57")<br />
50 (1.97")<br />
60 (2.36")<br />
44 (1.73")<br />
30<br />
(1.18")<br />
Ø4.3<br />
(0.16")<br />
22<br />
(0.86")<br />
20<br />
(0.78")<br />
30<br />
(1.18")<br />
54.5 (2.14")<br />
30<br />
(1.18")<br />
1/2 NPT<br />
Ø4.3<br />
(0.16")<br />
1/2 NPT<br />
22(0.86")<br />
20 (0.78")<br />
42 (1.65")<br />
40(1.57")<br />
50 (1.97")<br />
60 (2.36")<br />
44 (1.73")<br />
30<br />
(1.18")<br />
KB P1 - P2 - P3<br />
KM P1 - P2 - P3<br />
Ø4.3<br />
(0.16")<br />
22<br />
(0.86")<br />
20<br />
(0.78")<br />
30<br />
(1.18")<br />
54.5 (2.14")<br />
Ø12<br />
(0.47")<br />
20<br />
(0.79")<br />
P1<br />
23.1<br />
(0.91")<br />
30<br />
(1.18")<br />
1/2 N<br />
Ø8 (0.31")<br />
121 (4.76")<br />
30<br />
(1.18")<br />
Ø6.9 (0.27")<br />
31<br />
(1.22")<br />
Ø8 (0.31")<br />
69 (2.71")<br />
30<br />
(1.18")<br />
1/2 NPT<br />
KC P1 - P2 - P3<br />
KN P1 - P2 - P3<br />
P2 P3 P1 P2 P3<br />
Ø4.3<br />
(0.16")<br />
22(0.86")<br />
20 (0.78")<br />
42 (1.65")<br />
40(1.57")<br />
50 (1.97")<br />
60 (2.36")<br />
20<br />
(0.78")<br />
44 (1.73")<br />
Ø12 (0.47")<br />
23.1<br />
(0.90")<br />
30<br />
(1.18")<br />
Ø8 (0.31")<br />
121 (4.76")<br />
30<br />
(1.18")<br />
Ø6.9 (0.27")<br />
31<br />
(1.22")<br />
Ø8 (0.31")<br />
69 (2.71")<br />
30<br />
(1.18")<br />
KB Q1 L<br />
KM Q1 L<br />
KC Q1 L<br />
KN Q1 L<br />
KB N1 - KB N2<br />
KM N1 - KM N2<br />
KC N1 - KC N2<br />
KN N1 - KN N2<br />
77 (3.03")<br />
77 (3,03")<br />
Ø4.3<br />
(0.16")<br />
22<br />
(0.86")<br />
20<br />
(0.78")<br />
30<br />
(1.18")<br />
54.5 (2.14")<br />
20<br />
(0.79")<br />
30<br />
(1.18")<br />
1/2 NPT<br />
Ø4.3<br />
(0.16")<br />
1/2 NPT<br />
22(0.86")<br />
20 (0.78")<br />
42 (1.65")<br />
40(1.57")<br />
50 (1.97")<br />
60 (2.36")<br />
20<br />
(0.78")<br />
44 (1.73")<br />
30<br />
(1.18")<br />
Ø4.3<br />
(0.16")<br />
22<br />
(0.86")<br />
20<br />
(0.78")<br />
30<br />
(1.18")<br />
34 (1.34")<br />
54.5 (2.14")<br />
38,5<br />
(1.52")<br />
30<br />
(1.18")<br />
1/2 NPT<br />
Ø4.3<br />
(0.16")<br />
1/2 NPT<br />
22(0.86")<br />
20 (0.78")<br />
42 (1.65")<br />
40(1.57")<br />
50 (1.97")<br />
60 (2.36")<br />
34<br />
(1.33")<br />
38.5 (1.51")<br />
44 (1.73")<br />
30<br />
(1.18")<br />
Keys<br />
KX N1 KX N2 KX N3<br />
KX N4 KX N5<br />
43 (1.69")<br />
14 (0.55")<br />
9.5<br />
(0.37")<br />
9x4.6 (0.35x0.18")<br />
30.9<br />
(1.22")<br />
Cable glands<br />
KX P01<br />
KX P02<br />
Grommet<br />
KX P03<br />
CH24<br />
27 (1.06")<br />
CH24<br />
9<br />
(0.35")<br />
9<br />
(0.35")<br />
15 (0.59")<br />
27 (1.06")<br />
14 (0.55")<br />
9.5<br />
(0.37")<br />
9x4.6 (0.35x0.18")<br />
30 (1.18")<br />
22<br />
(0.87")<br />
11 (0.43")<br />
5x4.2 (0.2x0.18")<br />
17 (0.67")<br />
7.1 (0.28")<br />
30 (1.18")<br />
22<br />
(0.87")<br />
7 (0.28")<br />
5x4.2 (0.2x0.18")<br />
13 (0.51")<br />
Ø4.2 (0.18")<br />
5 (0.2")<br />
30 (1.18")<br />
15 (0.59")<br />
12.9 (0.51")<br />
12.9 (0.51")<br />
1.5 (0.06")<br />
CH24<br />
5.6<br />
(0.22")<br />
M20<br />
PG13.5<br />
M20<br />
7.9<br />
(0.31")<br />
CH = Spanner/Wrench<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com
electric<br />
Dimensions [mm (in)]<br />
Prewired metal limit switches, KP types<br />
D-23<br />
Top push rod plunger<br />
Metal plunger<br />
KP A1<br />
20 (0.79")<br />
40 (1.58")<br />
30<br />
(1.18")<br />
Ø4.3 (0.17")<br />
20<br />
(0.79")<br />
16 (0.63")<br />
M12 fixing head<br />
KP A2<br />
34 (1.34")<br />
40 (1.58")<br />
30<br />
(1.18")<br />
M12x1<br />
Ø4.3 (0.17")<br />
20<br />
(0.79")<br />
16 (0.63")<br />
Top roller push plunger<br />
Plastic or metal roller<br />
KP B1 - KP B2<br />
30<br />
(1.18")<br />
40 (1.58")<br />
12<br />
(0.47")<br />
30<br />
(1.18")<br />
Ø4.3 (0.17")<br />
20<br />
(0.79")<br />
16 (0.63")<br />
Top roller push plunger<br />
90° plastic roller<br />
KP B4<br />
30<br />
(1.18")<br />
40 (1.58")<br />
30<br />
(1.18")<br />
Ø4.3 (0.17")<br />
20<br />
(0.79")<br />
12<br />
(0.47")<br />
16 (0.63")<br />
M12 head top roller push plunger<br />
Plastic or metal roller<br />
KP B5 - KP B6<br />
44.8 (1.76")<br />
40 (1.58")<br />
12<br />
(0.47")<br />
30<br />
(1.18")<br />
Ø4.3 (0.17")<br />
20<br />
(0.79")<br />
M12x1<br />
16 (0.63")<br />
D<br />
90° plastic roller<br />
KP B7 - KP B8<br />
44.8 (1.76")<br />
40 (1.58")<br />
M12x1<br />
30<br />
(1.18")<br />
Ø4.3 (0.17")<br />
20<br />
(0.79")<br />
12<br />
(0.47")<br />
16 (0.63")<br />
Roller lever plunger<br />
Plastic or metal roller<br />
KP E1 - KP E2<br />
52 (2.05")<br />
40 (1.58")<br />
14 (0.55")<br />
Ø4.3 (0.17")<br />
20<br />
(0.79")<br />
24<br />
(0.94")<br />
4.5 (0.18")<br />
13.5 (0.49")<br />
Adjustable roller lever<br />
Plastic roller<br />
KP F1<br />
48-118 (1.89"-4.65")<br />
40 (1.58")<br />
18 (0.71")<br />
Ø4.3 (0.17")<br />
20<br />
(0.79")<br />
34,4<br />
(1.35") 4.5 (0.18")<br />
17.3 (0.68")<br />
Adjustable rod lever<br />
Metal rod<br />
KP L2<br />
max. 139 (5.47")<br />
40 (1.58")<br />
3 (0.12")<br />
5.5 (0.22")<br />
Ø4.3 (0.17")<br />
20<br />
(0.79")<br />
29<br />
(1.14")<br />
15.8 (0.62")<br />
Wobble stick<br />
Metal rod<br />
KP M2<br />
122 (4.8")<br />
40 (1.58")<br />
7.9 (0.31")<br />
Ø4.3 (0.17")<br />
20<br />
(0.79")<br />
30<br />
(1.18")<br />
16 (0.63")<br />
30<br />
(1.18")<br />
16 (0.63")<br />
30<br />
(1.18")<br />
16 (0.63")<br />
30<br />
(1.18")<br />
16 (0.63")<br />
Plastic limit switches, T series without reset button<br />
Limit switches without reset button<br />
TS1 01 - TL1 01<br />
5.3x7,3<br />
(0.20x0.28")<br />
30<br />
(1.18")<br />
34.5<br />
(1.36")<br />
60 (2.36")<br />
100.5 (3.95")<br />
16<br />
(0.63")<br />
31<br />
(1.22")<br />
TS1 05 20 - TL1 05 20<br />
TS1 05 21 - TL1 05 21<br />
Ø20x5<br />
(0.78x0.19")<br />
Metal<br />
or<br />
plastic<br />
5.3x7,3<br />
(0.20x0.28")<br />
30<br />
(1.18")<br />
62 (2.44")<br />
60 (2.36")<br />
128 (5.03")<br />
57.5 (2.26")<br />
31<br />
(1.22")<br />
TS1 05 24 - TL1 05 24<br />
Ø50x10<br />
(1.97x0.39")<br />
Rubber<br />
5.3x7,3<br />
(0.20x0.28")<br />
30<br />
(1.18")<br />
77 (3.03")<br />
60 (2.36")<br />
143 (5.63")<br />
31<br />
(1.22")<br />
60 (2.36")<br />
Ø5.3<br />
(0.20")<br />
40 (1.57")<br />
43 (1.69")<br />
PG13.5<br />
Ø5.3<br />
(0.20")<br />
40 (1.57")<br />
43 (1.69")<br />
PG13.5<br />
Ø5.3<br />
(0.20")<br />
40 (1.57")<br />
43 (1.69")<br />
PG13.5<br />
Limit switches without reset button<br />
TS1 09 - TL1 09<br />
5.3x7,3<br />
(0.20x0.28")<br />
Ø6 (0.23")<br />
Steel<br />
30<br />
(1.18")<br />
27<br />
(1.06")<br />
60 (2.36")<br />
195 (7.67")<br />
16<br />
(0.63")<br />
31<br />
(1.22")<br />
TL2 10<br />
5.3x7,3<br />
(0.20x0.28")<br />
Ø5.3<br />
(0.20")<br />
30<br />
(1.18")<br />
40 (1.57")<br />
30<br />
(1.18")<br />
60 (2.36")<br />
107 (4.21")<br />
7<br />
(0.27")<br />
31<br />
(1.22")<br />
43 (1.69")<br />
PG13.5<br />
Keys<br />
P32752<br />
Ø4.5<br />
(0.17")<br />
28<br />
(1.10")<br />
20<br />
(0.78")<br />
A20748<br />
8.5 (0.33")<br />
55 (2.16")<br />
13.5 (0.53")<br />
28.5<br />
(1.12")<br />
P32753 A20746 A20747<br />
20<br />
(0.78")<br />
15<br />
(0.59")<br />
21.5<br />
(0.84")<br />
28.5<br />
(1.12")<br />
31.43<br />
(1.23")<br />
15<br />
(0.59")<br />
72 (2.83")<br />
31<br />
(1.22")<br />
30<br />
(1.18")<br />
43 (1.69")<br />
Ø5.3<br />
(0.20")<br />
40 (1.57")<br />
43 (1.69")<br />
PG13.5<br />
Ø4.2<br />
(0.16")<br />
35 (1.37")<br />
26<br />
(1.02")<br />
29<br />
(1.14")<br />
13<br />
(0.51")<br />
50 (1.97")<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com
D-24<br />
Dimensions [mm (in)]<br />
Plastic limit switches, T series with reset button<br />
electric<br />
Limit switches with reset button<br />
TS2 01 - TL2 01<br />
TS2 05 20 - TL2 05 20<br />
TS2 05 21 - TL2 05 21<br />
TS2 05 24 - TL2 05 24<br />
60 (2.36")<br />
D<br />
5.3x7,3<br />
(0.20x0.28")<br />
30<br />
(1.18")<br />
34.5<br />
(1.36")<br />
60 (2.36")<br />
100.5 (3.95")<br />
16<br />
(0.63")<br />
31<br />
(1.22")<br />
Ø20x5<br />
(0.78x0.19")<br />
Plastic<br />
or<br />
Metal<br />
5.3x7,3<br />
(0.20x0.28")<br />
4.3 (0.17")<br />
30<br />
(1.18")<br />
62 (2.44")<br />
60 (2.36")<br />
128 (5.03")<br />
58.5 (2.3")<br />
31<br />
(1.22")<br />
Ø50x10<br />
(1.97x0.39")<br />
Rubber<br />
5.3x7,3<br />
(0.20x0.28")<br />
4.3 (0.17")<br />
30<br />
(1.18")<br />
77 (3.03")<br />
60 (2.36")<br />
143 (5.63")<br />
31<br />
(1.22")<br />
Ø5.3<br />
(0.20")<br />
40 (1.57")<br />
43 (1.69")<br />
PG13.5<br />
Ø5.3<br />
(0.20")<br />
40 (1.57")<br />
43 (1.69")<br />
PG13.5<br />
Ø5.3<br />
(0.20")<br />
40 (1.57")<br />
43 (1.69")<br />
PG13.5<br />
Rope-pull lever switches for normal stopping<br />
RS1 13 10 - RS3 13 10 - RS3 13 10<br />
TS1 13 10 - TL1 13 10<br />
16<br />
(0.63")<br />
Ø20<br />
(0.78")<br />
Ø4.3<br />
(0.16")<br />
22<br />
(0.86")<br />
20<br />
(0.78")<br />
55 (2.16") 49 (1.93")<br />
30<br />
(1.18")<br />
= =<br />
Ø20<br />
(0.78")<br />
5.3x7,3<br />
(0.20x0.28")<br />
30<br />
(1.18")<br />
46.5 (1.83")<br />
60 (2.36")<br />
31<br />
(1.22")<br />
30.5<br />
(1.20")<br />
35<br />
(1.37")<br />
PG11<br />
Ø5.3<br />
(0.20")<br />
40 (1.57")<br />
43 (1.69")<br />
PG13.5<br />
Rope-pull safety switches, EN 418 compliant<br />
RS13 13 10<br />
TL13 13 10<br />
16<br />
(0.63")<br />
Ø20<br />
(0.79")<br />
Ø4.3<br />
(0.16")<br />
22<br />
(0.86")<br />
20<br />
(0.78")<br />
49 (1.93")<br />
55 (2.16")<br />
30<br />
(1.18")<br />
= =<br />
Ø20<br />
(0.78")<br />
5.3x7,3<br />
(0.20x0.28")<br />
30<br />
(1.18")<br />
46.5 (1.83")<br />
60 (2.36")<br />
31<br />
(1.22")<br />
30.5<br />
(1.20")<br />
35<br />
(1.37")<br />
PG11<br />
Ø5.3<br />
(0.20")<br />
40 (1.57")<br />
43 (1.69")<br />
PG13.5<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com
electric<br />
Dimensions [mm (in)]<br />
Micro switches, KS types<br />
D-25<br />
Top push rod - metal plunger<br />
Pin<br />
KS A1<br />
High rod plunger<br />
KS A2<br />
Low rod plunger<br />
KS A3<br />
M12 fixing head<br />
KS A4<br />
Push button<br />
Hand operation<br />
KS A9<br />
23.3<br />
(0.92")<br />
25.4 (1")<br />
49.2 (1.94")<br />
16.4<br />
(0.65")<br />
Ø4.4<br />
(0.17")<br />
17.5<br />
(0.69")<br />
Ø2.3 (0.09")<br />
27.5<br />
(1.83")<br />
23.4<br />
(0.92")<br />
25.4 (1")<br />
49.2 (1.94")<br />
27.8<br />
(1.83")<br />
Ø4.4<br />
(0.17")<br />
17.5<br />
(0.69")<br />
Ø5.2 (0.2")<br />
Ø4 (0.16")<br />
27.5<br />
(1.83")<br />
23.3<br />
(0.92")<br />
25.4 (1")<br />
49.2 (1.94")<br />
22<br />
(0.87")<br />
Ø4.4<br />
(0.17")<br />
17.5<br />
(0.69")<br />
12.3 (0.40")<br />
10 (0.39")<br />
Ø7.15 (0.28")<br />
27.5<br />
(1.83")<br />
23.3<br />
(0.92")<br />
25.4 (1")<br />
49.2 (1.94")<br />
38.6<br />
(1.52")<br />
Ø4.4<br />
(0.17")<br />
17.5<br />
(0.69")<br />
M12xT1<br />
Ø8.3 (0.33")<br />
27.5<br />
(1.83")<br />
20.2<br />
(0.79")<br />
25.4 (1")<br />
49.2 (1.94")<br />
Ø4.4<br />
(0.17")<br />
17.5<br />
(0.69")<br />
33<br />
(1.3")<br />
D<br />
Top roller push plunger<br />
M12 fixing head<br />
KS B1<br />
M12 fixing head, 90° roller<br />
KS B2<br />
23.3<br />
(0.92")<br />
50.2<br />
(1.98")<br />
M12xT1<br />
Ø12.5x3.8<br />
(0.49"x0.15")<br />
23.3<br />
(0.92")<br />
50.2<br />
(1.98")<br />
M12<br />
Ø12.5x3.8<br />
(0.49"x0.15")<br />
25.4 (1")<br />
49.2 (1.94")<br />
Ø4.4<br />
(0.17")<br />
17.5<br />
(0.69")<br />
27.5<br />
(1.83")<br />
25.4 (1")<br />
49.2 (1.94")<br />
Ø4.4<br />
(0.17")<br />
17.5<br />
(0.69")<br />
27.5<br />
(1.83")<br />
Roller center push lever<br />
25mm long lever<br />
KS C1<br />
28mm long lever<br />
KS C2<br />
38mm long lever<br />
KS C3<br />
One-way roller lever<br />
KS C9<br />
R26.1<br />
(R1.05")<br />
20.2<br />
(0.79")<br />
26.2<br />
(1.03")<br />
33.7<br />
(1.33")<br />
Ø9.5x4<br />
(0.37"x0.16)<br />
33<br />
(1.3")<br />
20.2<br />
(0.79")<br />
26.2<br />
(1.03")<br />
R38 (R1.5")<br />
37.3<br />
(1.47")<br />
Ø9.5x4<br />
(0.37"x0.16)<br />
33<br />
(1.3")<br />
20.2<br />
(0.79")<br />
26.2<br />
(1.03")<br />
R48.5 (R1.91")<br />
37.3<br />
(1.47")<br />
Ø9.5x4<br />
(0.37"x0.16)<br />
33<br />
(1.3")<br />
R31.9<br />
(R1.2")<br />
20.2<br />
(0.79")<br />
26.2<br />
(1.03")<br />
44<br />
(1.73")<br />
Ø9.5x4<br />
(0.37"x0.16)<br />
33<br />
(1.3")<br />
25.4 (1")<br />
49.2 (1.94")<br />
Ø4.4<br />
(0.17")<br />
17.5<br />
(0.69")<br />
25.4 (1")<br />
49.2 (1.94")<br />
Ø4.4<br />
(0.17")<br />
17.5<br />
(0.69")<br />
25.4 (1")<br />
49.2 (1.94")<br />
Ø4.4<br />
(0.17")<br />
17.5<br />
(0.69")<br />
25.4 (1")<br />
49.2 (1.94")<br />
Ø4.4<br />
(0.17")<br />
17.5<br />
(0.69")<br />
Flat lever<br />
63mm long lever<br />
KS L1<br />
20.2<br />
(0.79")<br />
26.2<br />
(1.03")<br />
R63.5 (R2.5")<br />
29<br />
(1.14")<br />
4.9 (0.19")<br />
33<br />
(1.3")<br />
54mm long lever<br />
KS L2<br />
20.2<br />
(0.79")<br />
26.2<br />
(1.03")<br />
R54 (R2.13")<br />
29<br />
(1.14")<br />
4.9 (0.19")<br />
33<br />
(1.3")<br />
168.3mm long lever<br />
KS L3...<br />
20.2<br />
(0.79")<br />
26.2<br />
(1.03")<br />
168.3 (6.63")<br />
17 (0.67") max<br />
33<br />
(1.3")<br />
0.96<br />
25.4 (1")<br />
49.2 (1.94")<br />
Ø4.4<br />
(0.17")<br />
17.5<br />
(0.69")<br />
25.4 (1")<br />
49.2 (1.94")<br />
Ø4.4<br />
(0.17")<br />
17.5<br />
(0.69")<br />
25.4 (1")<br />
49.2 (1.94")<br />
16<br />
(0.63")<br />
17.5<br />
(0.69")<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com
D-26<br />
Dimensions [mm (in)]<br />
Foot switches<br />
electric<br />
KG1<br />
264 (10.39")<br />
M20<br />
150 (5.90")<br />
D<br />
86 (3.39")<br />
34<br />
(1.33")<br />
KG2<br />
285 (11.22")<br />
150 (5.90")<br />
34<br />
(1.33")<br />
M20<br />
86 (3.39")<br />
164 (6.45")<br />
KR1<br />
238.7 (9.4")<br />
140 (5.51")<br />
M20<br />
25<br />
(0.98")<br />
57 (2.24")<br />
KR2<br />
250 (9.84")<br />
140 (5.51")<br />
KGD<br />
516.5 (20.33")<br />
516.5 (20.33")<br />
25<br />
(0.98")<br />
M20<br />
75 (2.95")<br />
120 (4.72")<br />
286.6 (11.28")<br />
301.2 (11.86")<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com
electric<br />
Dimensions [mm (in)]<br />
Rotary cam switches GX series<br />
D-27<br />
Front mounting<br />
Type<br />
Dimensions<br />
L [mm (in)]<br />
A B C D E F G H I L M<br />
1 wafer 2 wafers 3 wafers 4 wafers 5 wafers 6 wafers<br />
D<br />
B<br />
A<br />
C<br />
1...5<br />
Drilling<br />
H<br />
L<br />
M<br />
E<br />
GX16 U 48 –– 39.5 45 48 26.5 23.5 28 6 12 5<br />
(1.89”) (1.55”) (1.77”) (1.89”) (1.04”) (0.92”) (1.1”) (0.24”) (0.47”) (0.20”)<br />
GX16 U25 48 60 ❶ 45 48 34 23.5 28 6 12 5<br />
(1.89”) (2.36”) (1.77”) (1.89”) (1.33”) (0.92”) (1.1”) (0.24”) (0.47”) (0.20”)<br />
GX20 U 48 –– 39.5 45 48 26.5 23.5 28 6 12 5<br />
(1.89”) (1.55”) (1.77”) (1.89”) (1.04”) (0.92”) (1.1”) (0.24”) (0.47”) (0.20”)<br />
GX20 U25 48 60 ❶ 45 48 34 23.5 28 6 12 5<br />
(1.89”) (2.36”) (1.77”) (1.89”) (1.33”) (0.92”) (1.1”) (0.24”) (0.47”) (0.20”)<br />
GX32 U 65 –– 53 58 66 34.5 26 28 7 14 5<br />
(2.56”) (2.09”) (2.28”) (2.59”) (1.36”) (1.02”) (1.1”) (0.27”) (0.55”) (0.20”)<br />
GX32 U25 65 80 ❶ 58 66 38 26 28 7 14 5<br />
(2.56”) (3.15”) (2.28”) (2.59”) (1.50”) (1.02”) (1.1”) (0.27”) (0.55”) (0.20”)<br />
GX40 U 65 –– 53 58 66 34.5 26 28 7 14 5<br />
(2.56”) (2.09”) (2.28”) (2.59”) (1.36”) (1.02”) (1.1”) (0.27”) (0.55”) (0.20”)<br />
GX40 U25 65 80 ❶ 58 66 38 26 28 7 14 5<br />
(2.56”) (3.15”) (2.28”) (2.59”) (1.50”) (1.02”) (1.1”) (0.27”) (0.55”) (0.20”)<br />
42.5 51 59.5 68 76.5 85<br />
(1.67”) (2.00”) (2.34”) (2.67”) (3.01”) (3.35”)<br />
39.5 48 56.5 65 73.5 82<br />
(1.55”) (1.89”) (2.22”) (2.55”) (2.89”) (3.22”)<br />
42.5 51 59.5 68 76.5 85<br />
(1.67”) (2.00”) (2.34”) (2.67”) (3.01”) (3.35”)<br />
39.5 48 56.5 65 73.5 82<br />
(1.55”) (1.89”) (2.22”) (2.55”) (2.89”) (3.22”)<br />
47.5 59.5 71.5 83.5 95.5 107.5<br />
(1.87”) (2.34”) (2.81”) (3.29”) (3.75”) (4.23”)<br />
48 60 72 84 96 108<br />
(1.89”) (2.36”) (2.83”) (3.30”) (3.77”) (4.25”)<br />
47.5 59.5 71.5 83.5 95.5 107.5<br />
(1.87”) (2.34”) (2.81”) (3.29”) (3.75”) (4.23”)<br />
48 60 72 84 96 108<br />
(1.89”) (2.36”) (2.83”) (3.30”) (3.77”) (4.25”)<br />
D<br />
I<br />
L<br />
G<br />
F<br />
Rear view<br />
❶ Padlockable handle.<br />
Door coupling O version<br />
Drilling for 4-screw wafer<br />
fixing on mounting plate<br />
Coupling and front plate<br />
fixing on the door<br />
K<br />
S<br />
1...5<br />
E<br />
B<br />
A<br />
C<br />
M<br />
T<br />
U<br />
U<br />
T<br />
P<br />
D<br />
DIN35<br />
IEC/EN 60715<br />
N<br />
52<br />
L<br />
G<br />
F<br />
Rear view<br />
Type<br />
Dimensions<br />
A C D E F G K M N O P S T U<br />
GX16 O 48 39.5 45 48 26.5 23.5 –– 28 6 52 66.5 48-58 12 5<br />
(1.89”) (1.55”) (1.77”) (1.89”) (1.04”) (0.92”) (1.1”) (0.24”) (2.04”) (2.61”) (1.89”-2.28”) (0.47”) (0.20”)<br />
GX16 O88 48 ❶ 45 48 34 23.5 36 –– 6 52 66.5 45-55 12 5<br />
(1.89”) (1.77”) (1.89”) (1.33”) (0.92”) (1.42”) (0.24”) (2.04”) (2.61”) (1.77”-2.16”) (0.47”) (0.20”)<br />
GX20 O 48 39.5 45 48 26.5 23.5 –– 28 6 52 66.5 48-58 12 5<br />
(1.89”) (1.55”) (1.77”) (1.89”) (1.04”) (0.92”) (1.1”) (0.24”) (2.04”) (2.61”) (1.89”-2.28”) (0.47”) (0.20”)<br />
GX20 O88 48 ❶ 45 48 34 23.5 36 –– 6 52 66.5 45-55 12 5<br />
(1.89”) (1.77”) (1.89”) (1.33”) (0.92”) (1.42”) (0.24”) (2.04”) (2.61”) (1.77”-2.16”) (0.47”) (0.20”)<br />
GX32 O 65 53 58 66 34.5 26 –– 28 7 68 78 48-58 14 5<br />
(2.56”) (2.09”) (2.28”) (2.59”) (1.36”) (1.02”) (1.1”) (0.27”) (2.68”) (3.07”) (1.89”-2.28”) (0.55”) (0.20”)<br />
GX32 O88 65 ❶ 58 66 38 26 48 –– 7 68 78 45-55 14 5<br />
(2.56”) (2.28”) (2.59”) (1.49”) (1.02”) (1.89”) (0.27”) (2.68”) (3.07”) (1.77”-2.16”) (0.55”) (0.20”)<br />
GX40 O 65 53 58 66 34.5 26 –– 28 7 68 78 48-58 14 5<br />
(2.56”) (2.09”) (2.28”) (2.59”) (1.36”) (1.02”) (1.1”) (0.27”) (2.68”) (3.07”) (1.89”-2.28”) (0.55”) (0.20”)<br />
GX40 O88 65 ❶ 58 66 38 26 48 –– 7 68 78 45-55 14 5<br />
(2.56”) (2.28”) (2.59”) (1.49”) (1.02”) (1.89”) (0.27”) (2.68”) (3.07”) (1.77”-2.16”) (0.55”) (0.20”)<br />
❶ Padlockable handle.<br />
L [mm (in)]<br />
1 wafer 2 wafers 3 wafers 4 wafers 5 wafers 6 wafers<br />
40 48.5 57 65.5 74 82.5<br />
(1.57”) (1.90”) (2.24”) (2.57”) (2.91”) (3.24”)<br />
40 48.5 57 65.5 74 82.5<br />
(1.57”) (1.90”) (2.24”) (2.57”) (2.91”) (3.24”)<br />
40 48.5 57 65.5 74 82.5<br />
(1.57”) (1.90”) (2.24”) (2.57”) (2.91”) (3.24”)<br />
40 48.5 57 65.5 74 82.5<br />
(1.57”) (1.90”) (2.24”) (2.57”) (2.91”) (3.24”)<br />
48.7 60.7 72.7 84.7 96.7 108.7<br />
(1.91”) (2.38”) (2.86”) (3.33”) (3.80”) (4.27”)<br />
48.7 60.7 72.7 84.7 96.7 108.7<br />
(1.91”) (2.38”) (2.86”) (3.33”) (3.80”) (4.27”)<br />
48.7 60.7 72.7 84.7 96.7 108.7<br />
(1.91”) (2.38”) (2.86”) (3.33”) (3.80”) (4.27”)<br />
48.7 60.7 72.7 84.7 96.7 108.7<br />
(1.91”) (2.38”) (2.86”) (3.33”) (3.80”) (4.27”)<br />
Mounting in enclosure<br />
Drilling for enclosure fixing<br />
A<br />
C<br />
L<br />
F<br />
L1<br />
F<br />
A1<br />
C1<br />
M<br />
R<br />
D<br />
N<br />
Type Enclosure N° of wafers Protection Cable glands<br />
size L L1 A A1 C C1 D F M N L L1 degree<br />
GX16 90x90 1-2 3-5 90 90 79 63 4.5 25 19 30 71.3 98.3<br />
GX20 (3.54”x3.54”) 1-2 3-5 (3.54”) (3.54”) (3.11”) (2.48”) (0.17”) (0.98”) (0.74”) (1.18”) (2.80”) (3.87”)<br />
IP65 4 PG 16<br />
GX32 110x110 1-2 3-4 110 110 98.4 83 4.5 32 21 39.5 85.5 119.5<br />
GX40 (4.33”x4.33”) 1-2 3-4 (4.33”) (4.33”) (3.87”) (3.26”) (0.17”) (1.25”) (0.82”) (1.55”) (3.36”) (4.70”)<br />
IP65 4 PG 21<br />
Flush mounting Ø 22mm<br />
Flush mounting Ø 22mm<br />
1-5<br />
1-5<br />
11.25 (0.44")<br />
fl 22.5<br />
(0.88")<br />
45 (1.77")<br />
L<br />
18.5<br />
(0.72")<br />
30 (1.18")<br />
28<br />
(1.10")<br />
11.25 (0.44")<br />
fl 22.5<br />
(0.88")<br />
45 (1.77")<br />
L<br />
18.5<br />
(0.72") 23 (0.90")<br />
28 (1.10")<br />
Type<br />
L [mm (in)]<br />
1 wafer 2 wafers 3 wafers 4 wafers<br />
GX16 35 43.5 52 60.5<br />
(1.37”) (1.71”) (2.04”) (2.38”)<br />
Type<br />
L [mm (in)]<br />
1 wafer 2 wafers 3 wafers 4 wafers<br />
GX16 35 43.5 52 60.5<br />
(1.37”) (1.71”) (2.04”) (2.38”)<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com
D-28<br />
Dimensions [mm (in)]<br />
Rotary cam switches GN series<br />
electric<br />
Front mounting<br />
Type<br />
Dimensions<br />
L<br />
D<br />
M<br />
B<br />
A<br />
J<br />
D3<br />
Rear view<br />
C<br />
Wafer and front plate fixing on the door<br />
D1<br />
D2<br />
M<br />
2-screw drillings<br />
for types up to GN63<br />
G<br />
D<br />
L<br />
H<br />
D1<br />
K<br />
D2<br />
4-screw drillings for GN125<br />
and “4V” suffix types only<br />
1...5<br />
F<br />
E<br />
N<br />
A B C D D1 D2 D3 E F Ø G H J K M N<br />
1 wafer 2 wafers 3 wafers 4 wafers 5 wafers 6 wafers<br />
GN12 48 60 39.5 38 12 5 4.3 26.5 23.5 38 5 36 36 48 6 32.5 42.1 51.7 61.3 70.9 80.5<br />
(1.89”) (2.36”) (1.55”) (1.50”) (0.47”) (0.20”) (0.17”) (1.04”) (0.92”) (1.50”) (0.20”) (1.42”) (1.42”) (1.89”) (0.24”) (1.28”) (1.66”) (2.03”) (2.41”) (2.79”) (3.17”)<br />
GN12∆ 65 80 53 38 14 5 4.3 34.5 26 58.5 5.5 48 48 65 7 39.2 48.8 58.4 68 77.6 87.2<br />
(2.56”) (3.15”) (2.09”) (1.50”) (0.55”) (0.20”) (0.17”) (1.36”) (1.02”) (2.30”) (0.22”) (1.89”) (1.89”) (2.56”) (0.27”) (1.54”) (1.92”) (2.30”) (2.68”) (3.05”) (3.43”)<br />
GN20 48 60 39.5 39 12 5 4.3 26.5 23.5 38 5 36 36 48 6 33.1 42.8 52.5 62.2 71.9 81.6<br />
(1.89”) (2.36”) (1.55”) (1.53”) (0.47”) (0.20”) (0.17”) (1.04”) (0.92”) (1.50”) (0.20”) (1.42”) (1.42”) (1.89”) (0.24”) (1.30”) (1.68”) (2.07”) (2.45”) (2.83”) (3.21”)<br />
GN20∆ 65 80 53 39 14 5 4.3 34.5 26 58.5 5.5 48 48 65 7 39.8 49.5 59.2 68.9 78.6 88.3<br />
(2.56”) (3.15”) (2.09”) (1.53”) (0.55”) (0.20”) (0.17”) (1.36”) (1.02”) (2.30”) (0.22”) (1.89”) (1.89”) (2.56”) (0.27”) (1.57”) (1.95”) (2.33”) (2.71”) (3.09”) (3.48”)<br />
GN25 48 60 39.5 43 12 5 4.3 26.5 23.5 38 5 36 36 48 6 37.5 51.1 64.7 78.2 91.9 105.5<br />
(1.89”) (2.36”) (1.55”) (1.69”) (0.47”) (0.20”) (0.17”) (1.04”) (0.92”) (1.50”) (0.20”) (1.42”) (1.42”) (1.89”) (0.24”) (1.48”) (2.01”) (2.55”) (3.08”) (3.62”) (4.15”)<br />
GN25∆ 65 80 53 43 14 5 4.3 34.5 20 58.5 5.5 48 48 65 7 44.2 57.8 71.4 85 98.6 112.2<br />
(2.56”) (3.15”) (2.09”) (1.69”) (0.55”) (0.20”) (0.17”) (1.36”) (0.79”) (2.30”) (0.22”) (1.89”) (1.89”) (2.56”) (0.27”) (1.74”) (2.27”) (2.81”) (3.35”) (3.88”) (4.42”)<br />
GN32 65 80 53 56 14 5 4.3 34.5 26 58.5 5.5 48 48 65 7 40.9 54.5 68.1 81.7 95.3 108.9<br />
(2.56”) (3.15”) (2.09”) (2.20”) (0.55”) (0.20”) (0.17”) (1.36”) (1.02”) (2.30”) (0.22”) (1.89”) (1.89”) (2.56”) (0.27”) (1.61”) (2,14”) (2.68”) (3.22) (3.75”) (4.29”)<br />
GN40 65 80 53 58 14 5 4.3 34.5 26 58.5 5.5 48 48 65 7 43.5 58.6 73.7 88.8 103.9 119<br />
(2.56”) (3.15”) (2.09”) (2.28”) (0.55”) (0.20”) (0.17”) (1.36”) (1.02”) (2.30”) (0.22”) (1.89”) (1.89”) (2.56”) (0.27”) (1.71”) (2.31”) (2.90”) (3.50”) (4.09”) (4.68”)<br />
GN63 65 80 53 62 14 5 4.3 34.5 26 58.5 5.5 48 68 65 7 47.3 65.4 83.5 101.6 119.7 137.8<br />
(2.56”) (3.15”) (2.09”) (2.44”) (0.55”) (0.20”) (0.17”) (1.36”) (1.02”) (2.30”) (0.22”) (1.89”) (2.68”) (2.56”) (0.27”) (1.86”) (2.57”) (3.29”) (4.00”) (4.71”) (5.42”)<br />
GN125 90 110 70.5 86 16 6 5.3 41.5 28 84 7.5 68 68 90 9 67.3 96.4 125.5 154.6 183.7 212.8<br />
(3.54”) (4.33”) (2.77”) (3.38”) (0.63”) (0.24”) (0.21”) (1.63”) (1.10”) (3.31”) (0.29”) (2.68”) (2.68”) (3.54”) (0.35”) (2.65”) (3.79”) (4.94”) (6.09”) (7.23”) (8.38”)<br />
∆ Dimensions for U06 and U25 versions<br />
Door coupling<br />
Drillings for 4-screw wafer fixing on mounting plate<br />
K<br />
K<br />
S<br />
1...5<br />
D2<br />
D2<br />
A<br />
C<br />
D1<br />
K<br />
D1<br />
Foratura 4 viti per<br />
elementi<br />
D2<br />
2-screw drillings for<br />
types up to GN63<br />
4-screw drillings for GN125<br />
and “4V” suffix types only<br />
L<br />
E<br />
Type Dimensions L<br />
A D1 D2 E K S 1 wafer 2 wafers 3 wafers 4 wafers<br />
GN12-O88 65 (2.56”) 14 (0.55”) 5 (0.20”) 34.5 (1.36”) 48 (1.89”) 45-55 (1.77”-2.16”) 37.58 (1.48”) 47.1 (1.85”) 56.7 (2.23”) 66.3 (2.61”)<br />
GN20-O88 65 (2.56”) 14 (0.55”) 5 (0.20”) 34.5 (1.36”) 48 (1.89”) 45-55 (1.77”-2.16”) 38.1 (1.50”) 47.8 (1.88”) 57.5 (2.26”) 67.2 (2.64”)<br />
GN25-O88 65 (2.56”) 14 (0.55”) 5 (0.20”) 34.5 (1.36”) 48 (1.89”) 45-55 (1.77”-2.16”) 42.5 (1.67”) 56.1 (2.21”) 65.7 (2.59”) 83.2 (3.27”)<br />
GN12-O68 48 (1.89”) 12 (0.47”) 5 (0.20”) 26.5 (1.04”) 36 (1.42”) 45-55 (1.77”-2.16”) 37.5 (1.48”) 47.1 (1.85”) 56.7 (2.23”) 66.3 (2.61”)<br />
GN20-O68 48 (1.89”) 12 (0.47”) 5 (0.20”) 26.5 (1.04”) 36 (1.42”) 45-55 (1.77”-2.16”) 38.1 (1.50”) 47.8 (1.88”) 57.5 (2.26”) 67.2 (2.64”)<br />
GN25-O68 48 (1.89”) 12 (0.47”) 5 (0.20”) 26.5 (1.04”) 36 (1.42”) 45-55 (1.77”-2.16”) 42.5 (1.67”) 56.1 (2.21”) 65.7 (2.59”) 83.2 (3.27”)<br />
GN32 65 (2.56”) 14 (0.55”) 5 (0.20”) 34.5 (1.36”) 48 (1.89”) 45-55 (1.77”-2.16”) 49.2 (1.94”) 62.8 (2.47”) 76.4 (3.00”) 90 (3.54”)<br />
GN40 65 (2.56”) 14 (0.55”) 5 (0.20”) 34.5 (1.36”) 48 (1.89”) 45-55 (1.77”-2.16”) 45.9 (1.81”) 59.5 (2.34”) 73.1 (2.88”) 86.7 (3.41”)<br />
GN63 65 (2.56”) 14 (0.55”) 5 (0.20”) 34.5 (1.36”) 48 (1.89”) 45-55 (1.77”-2.16”) 54.3 (2.14”) 72.4 (2.85”) 90.5 (3.56”) 108.6 (4.27”)<br />
GN125 90 (3.54”) 16 (0.63”) 6 (0.24”) 41.5 (1.63”) 68 (2.68”) 45-55 (1.77”-2.16”) 74.8 (2.94”) 103.9 (4.09”) 133 (5.23”) 162.1 (6.38”)<br />
Mounting in enclosure<br />
A<br />
Drilling for enclosure fixing<br />
C<br />
L<br />
F<br />
L1<br />
F<br />
A1<br />
C1<br />
M<br />
R<br />
D<br />
N<br />
Type Enclosure N° of wafers Protection Conduits<br />
size L L1 A A1 C C1 D F M N L L1 degree<br />
GN12 65x65<br />
65 65 54 38 4.3 19 13 25 55.5 75<br />
1-2 3-4<br />
(2.55”x2.55”) (2.55”) (2.55”) (2.12”) (1.49”) (0.16”) (0.74”) (0.51”) (0.98”) (2.18”) (2.95”)<br />
IP54 4 PG 11<br />
GN12 1-2 3-4<br />
75 75 64 50 4.5 19 14 28 57.5 79.8<br />
GN20 75x75 1-2 3-4<br />
(2.95”) (2.95”) (2.51”) (1.96”) (0.17”) (0.74”) (0.55”) (1.10”) (2.26”) (3.14”)<br />
GN25 1 2-3<br />
IP65 4 PG 13.5<br />
GN20 1-3 4-6<br />
GN25<br />
1-2 3-4 90 90 63 79 4.5 25 19 30 71.3 98.3<br />
90x90<br />
GN32 1-2 3-4 (3.54”) (3.54”) (2.48”) (3.11”) (0.17”) (0.98”) (0.74”) (1.18”) (2.80”) (3.87”)<br />
IP65 4 PG 16<br />
GN40 1 2-3<br />
GN32 1-3 4-5<br />
GN40<br />
1-2 3-4 125 175 112 146 5.5 32 21 68 84.3 118.3<br />
110x110<br />
GN63 1-2 3-4 (4.92”) (6.88”) (4.40”) (5.74”) (0.21”) (1.25”) (0.82”) (2.67”) (3.31”) (4.65”)<br />
IP65 4 PG 21<br />
GN125 1 2<br />
Flush mounting Ø 22mm<br />
Flush mounting Ø 22mm<br />
Type Dimensions L<br />
Ø A E P 1 wafer 2 wafers 3 wafers 4 wafers<br />
GN12 28 30 58 41.5 51.1 60.7 70.3<br />
(1.10”) (1.18”) (2.28”) (1.63”) (2.01”) (2.39”) (2.77”)<br />
GN20 28 30 58 42.1 51.8 61.5 71.2<br />
(1.10”) (1.18”) (2.28”) (1.66”) (2.04”) (2.42”) (2.80”)<br />
GN25 28 30 58 46.5 60.1 73.7 87.3<br />
(1.10”) (1.18”) (2.28”) (1.83”) (2.37” (2.90”) (3.44”)<br />
Type Dimensions L<br />
Ø A E P 1 wafer 2 wafers 3 wafers 4 wafers<br />
GN12 28 23 58 41.5 51.1 60.7 70.3<br />
(1.10”) (0.90”) (2.28”) (1.63”) (2.01”) (2.39”) (2.77”)<br />
GN20 28 23 58 42.5 51.8 61.5 71.2<br />
(1.10”) (0.90”) (2.28”) (1.67”) (2.04”) (2.42”) (2.80”)<br />
GN25 28 23 58 46.5 60.1 73.7 87.3<br />
(1.10”) (0.90”) (2.28”) (1.83”) (2.37”) (2.90”) (3.44”)<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com
8<br />
9<br />
34<br />
A<br />
2<br />
7<br />
10<br />
A2<br />
11<br />
11<br />
31<br />
1<br />
11<br />
32<br />
31<br />
22<br />
5<br />
2<br />
A1<br />
6<br />
34<br />
3<br />
14<br />
12<br />
4<br />
electric<br />
Dimensions [mm (in)]<br />
Timers<br />
D-29<br />
Timers<br />
TM<br />
Ø4.2 (0.16")<br />
43.7 (1.72")<br />
AT1P - AT1CP - ATD - AT1DP<br />
BTPM1 - BTPM - BT2N<br />
100 (3.94")<br />
100 (3.94")<br />
D<br />
104.7 (4.12")<br />
98.3 (3.87")<br />
45 (1.77")<br />
90 (3.54")<br />
18<br />
(0.70")<br />
5<br />
(0.19")<br />
58 (2.28")<br />
59.9 (2.35")<br />
Timers<br />
L48<br />
80 (3.15")<br />
13<br />
(0.51")<br />
3.5 (0.14")<br />
35<br />
(1.37")<br />
48 (1.89")<br />
Accessories<br />
S8 - S11<br />
65 (2.56")<br />
L48 P8<br />
43.50<br />
(1.71")<br />
33<br />
(1.30")<br />
43.50<br />
(1.71")<br />
20.50<br />
(0.80")<br />
1 8<br />
7 B<br />
14 3<br />
12 4 5<br />
L48 P11<br />
47 (1.85")<br />
33<br />
(1.30")<br />
47 (1.85")<br />
20.50<br />
(0.80")<br />
32 24<br />
6 21<br />
38 (1.49")<br />
27<br />
(1.06")<br />
48 (1.89")<br />
27<br />
(1.06")<br />
76 (2.99")<br />
103 (4.05")<br />
45 (1.77")<br />
45 (1.77")<br />
79 (3.11")<br />
79 (3.11")<br />
22.5<br />
(0.88")<br />
22.5<br />
(0.88")<br />
DRPL<br />
Accessories<br />
CE106<br />
CE107<br />
99.5 (3.91")<br />
22.5<br />
(0.88")<br />
10<br />
(0.39")<br />
22.5<br />
(0.88")<br />
10<br />
(0.39")<br />
78.8 (3.10")<br />
94 (3.70")<br />
84 (3.30")<br />
Ø4.5 (0.17")<br />
110 (4.33")<br />
100 (3.93")<br />
Ø4.5 (0.17")<br />
45<br />
(1.77")<br />
Cutout<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com
D-30<br />
Dimensions [mm (in)]<br />
Protection relays<br />
electric<br />
Protection relays<br />
PMV10<br />
PMV - PMF<br />
PMA<br />
Ø4.2 (0.16")<br />
43.7 (1.72")<br />
Ø4.2 (0.16") 43.7 (1.72")<br />
Ø4.2 (0.16")<br />
43.7 (1.72")<br />
D<br />
104.7 (4.12")<br />
98.3 (3.87")<br />
45 (1.77")<br />
90 (3.54")<br />
104.7 (4.12")<br />
98.3 (3.87")<br />
45 (1.77")<br />
90 (3.54")<br />
18<br />
(0.70")<br />
35.8 (1.41")<br />
5<br />
(0.19")<br />
58 (2.28")<br />
59.9 (2.36")<br />
53.5 (2.10")<br />
5<br />
(0.19")<br />
58 (2.28")<br />
59.9 (2.35")<br />
Liquid level control relays<br />
Level relays<br />
LVM25 - LVMP05<br />
LVM20<br />
LVM30 - LVM40 - LVMP10<br />
Ø4.2 (0.16")<br />
43.7 (1.72")<br />
Ø4.2 (0.16") 43.7 (1.72")<br />
Ø4.2 (0.16")<br />
43.7 (1.72")<br />
104.7 (4.12")<br />
98.3 (3.87")<br />
45 (1.77")<br />
90 (3.54")<br />
104.7 (4.12")<br />
98.3 (3.87")<br />
45 (1.77")<br />
90 (3.54")<br />
104.7 (4.12")<br />
98.3 (3.87")<br />
45 (1.77")<br />
90 (3.54")<br />
104.7 (4.12")<br />
98.3 (3.87")<br />
45 (1.77")<br />
90 (3.54")<br />
5<br />
(0.19")<br />
58 (2.28")<br />
59.9 (2.35")<br />
18<br />
(0.70")<br />
5<br />
(0.19")<br />
58 (2.28")<br />
59.9 (2.35")<br />
35.8 (1.41")<br />
5<br />
(0.19")<br />
58 (2.28")<br />
59.9 (2.36")<br />
53.5 (2.10")<br />
5<br />
(0.19")<br />
58 (2.28")<br />
59.9 (2.35")<br />
Electrodes and electrode holders<br />
SN1<br />
SCM...<br />
CGL125...<br />
PS31<br />
PS3S<br />
8<br />
(0.31")<br />
100 (3.94")<br />
8<br />
19.5<br />
(0.77")<br />
53 (2.09")<br />
L<br />
M3.5<br />
7 (0.28")<br />
18 (0.71")<br />
21 (0.83")<br />
3/8" GAS<br />
M4<br />
TYPE L mm / in<br />
SCM04 40 / 1.6<br />
SCM50 500 / 9.7<br />
SCM100 1000 / 39.4<br />
L<br />
47 (1.85")<br />
L<br />
22 (0.87")<br />
3/8" GAS<br />
TYPE L mm / in<br />
CGL125 3 300 / 11.8<br />
CGL125 5 500 / 19.7<br />
CGL125 7 700 / 25.6<br />
CGL125 10 1000 / 39.4<br />
48 (1.89")<br />
300 (11.8")<br />
25 (0.98")<br />
1/2" GAS<br />
40 (1.57") 20<br />
(0.79")<br />
2" GAS<br />
78 (3.07") 28<br />
(1.1")<br />
6 (0.24")<br />
M4<br />
Rods<br />
ASTA 460 MM4<br />
ASTA 960 MM4<br />
ASTA 460 MM6<br />
ASTA 960 MM6<br />
Coupler<br />
RE213<br />
460 (18.1")<br />
960 (37.8")<br />
460 (18.1")<br />
960 (37.8")<br />
30<br />
(1.18")<br />
M4<br />
M4<br />
M6<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com
electric<br />
Dimensions [mm (in)]<br />
Digital metering instruments and current transformers<br />
D-31<br />
Digital instruments<br />
DMK7 - DMK8<br />
Ø4.2 (0.16")<br />
43.8 (1.72")<br />
Multimeters DMK2<br />
96 (3.78")<br />
14<br />
(0.55")<br />
62 (2.44")<br />
6<br />
(0.23")<br />
Cutout<br />
91<br />
104.7 (4.12")<br />
98.3 (3.87")<br />
45 (1.77")<br />
90 (3.54")<br />
96 (3.78")<br />
90 (3.54")<br />
91<br />
D<br />
53.5 (2.10")<br />
5<br />
(0.19")<br />
58 (2.28")<br />
DMK3 - DMK40<br />
12<br />
(0.47")<br />
82 (3.22")<br />
6<br />
(0.23")<br />
91 (3.58")<br />
96 (3.78")<br />
90 (3.54")<br />
91 (3.58")<br />
96 (3.78")<br />
DMK0 - DMK1<br />
96 (3.78")<br />
16 (0.63")<br />
81 (3.19")<br />
9<br />
(0.35")<br />
91 (3.58")<br />
DMK5 - DMK6<br />
60 (2.36")<br />
105 (4.13")<br />
55 (2.16")<br />
36<br />
95 (3.74")<br />
90 (3.54")<br />
44 (1.73")<br />
48 (1.89")<br />
45 (1.77")<br />
90 (3.54")<br />
63 (2.48")<br />
45 (1.77")<br />
1<br />
Current transformers<br />
DM1T<br />
DM2T<br />
DM3T<br />
52 (2.05")<br />
9.5<br />
(0.37")<br />
46.5 (1.83")<br />
52 (2.05")<br />
9.5<br />
(0.37")<br />
46.5 (1.83")<br />
71 (2.8")<br />
9.5<br />
(0.37")<br />
62.5 (2.46")<br />
Ø22<br />
(0.87")<br />
28<br />
(1.1")<br />
65.5 (2.58")<br />
27.5<br />
(1.08")<br />
56.5 (2.22")<br />
28<br />
(1.1")<br />
Ø23<br />
(0.9")<br />
20<br />
(0.74") 25<br />
(0.98")<br />
30<br />
(1.81")<br />
10 (0.39")<br />
12.5 (0.49")<br />
15 (0.59")<br />
65.5 (2.58")<br />
27.5<br />
(1.08")<br />
56.5 (2.22")<br />
36.5<br />
(3.19")<br />
Ø30<br />
(1.18")<br />
25<br />
(0.98")<br />
30<br />
(1.81")<br />
40<br />
(1.57")<br />
10 (0.39")<br />
20 (0.74")<br />
40<br />
(0.59")<br />
81.5 (3.19")<br />
44.5 (1.75")<br />
72.5 (2.85")<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com
D-32<br />
Dimensions [mm (in)]<br />
Soft starters<br />
electric<br />
ADXM 06BP - ADXM 12BP - ADXM 18BP<br />
45 (1.77") 126 (4.96")<br />
ADXM 25BP - ADXM 45BP<br />
90 (3.54")<br />
109 (4.29")<br />
D<br />
114 (4.49")<br />
110 (4.33")<br />
83 (3.27")<br />
117 (4.61")<br />
Automatic power factor controllers<br />
DCRK5 - DCRK7<br />
Cutout<br />
DCRK8 - DCRK12<br />
Cutout<br />
65<br />
(2.56")<br />
53<br />
(2.08")<br />
31<br />
(1.22")<br />
91 (3.58")<br />
62<br />
(2.44")<br />
52<br />
(2.04")<br />
31<br />
(1.22")<br />
138.5 (5.45")<br />
96 (3.78")<br />
DCRJ8 - DCRJ12 - DCRJ12F<br />
Cutout<br />
62<br />
(2.44")<br />
52<br />
(2.04")<br />
7.7<br />
(0.30")<br />
144 (5.67")<br />
138.5 (5.45")<br />
144 (5.67")<br />
138.5 (5.45")<br />
PA96x96 (3.78"X3.78")<br />
91 (3.58")<br />
144 (5.67")<br />
PACR<br />
103.1 (4.08")<br />
114.1 (4.49")<br />
138.5 (5.45")<br />
58 (2.28")<br />
90 (3.54")<br />
50 (1.97")<br />
76.2 (3")<br />
100 (3.94")<br />
96 (3.78")<br />
6<br />
(0.23")<br />
144 (5.67")<br />
7.7<br />
(0.30")<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com
electric<br />
Dimensions [mm (in)]<br />
Automatic transfer switch controllers<br />
D-33<br />
ATL<br />
Cutout<br />
94 (3.7")<br />
79<br />
(3.11")<br />
31<br />
(1.22")<br />
138.5 (5.45")<br />
D<br />
144 (5.67")<br />
PACR<br />
138.5 (5.45")<br />
144 (5.67")<br />
7.9(0.30")<br />
Programmable logic relays<br />
Base modules<br />
LRD10<br />
LRD12<br />
5.08 (0.2")<br />
LRD20<br />
Ø4.5 (0.18") Ø4.5 (0.18")<br />
LRD<br />
57.30 (2.26")<br />
49.30 (1.94")<br />
31.50 (1.24")<br />
+ - I1 I2 I3 I4 I5 I6 A1 A2<br />
+ -<br />
I1 I2 I3 I4 I5 I6 I7 I8<br />
A1 A2 A3 A4<br />
106 (4.17")<br />
98 (3.86")<br />
74 (2.91")<br />
90 (3.54")<br />
68 (2.28")<br />
45 (1.77")<br />
35.40 (1.36")<br />
Q1 Q2 Q3 Q4<br />
Q1<br />
Q2<br />
Q3 Q4 Q5 Q6 Q7 Q8<br />
72 (2.83")<br />
80 (3.15")<br />
126 (4.96")<br />
5 (0.2")<br />
59.60 (2.35")<br />
Expansion and communication modules<br />
LRE...<br />
8<br />
5<br />
(0.2")<br />
54.6 (2.15")<br />
44.3 (1.74")<br />
Power supply module<br />
LRX1V3 D024<br />
72 (2.83")<br />
60 (2.36")<br />
5<br />
(0.2")<br />
52.3 (2.06")<br />
44.3 (1.74")<br />
90 (3.54")<br />
(0.3") 38 (1.5")<br />
Ø4.5 (0.18")<br />
98 (3.86")<br />
106 (4.17")<br />
45 (1.77")<br />
68 (2.28")<br />
90 (3.54")<br />
97.9 (3.85")<br />
106 (4.17")<br />
45 (1.77")<br />
68 (2.28")<br />
Ø4.5 (0.18")<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com
Wiring diagrams<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com
W<br />
Wiring diagrams<br />
®<br />
electric<br />
®<br />
electric<br />
100% electricity<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com
W-2 Wiring diagrams<br />
Manual motor starters and protectors<br />
electric<br />
W<br />
MANUAL STARTERS<br />
SM1 - SM2 - SM3 - LMS25<br />
Three phase<br />
LINE<br />
L1 L2 L3<br />
Single phase or DC<br />
LINE<br />
L1 L2<br />
ADD-ON BLOCKS<br />
SMX11 20 SMX11 11<br />
SMX21 11<br />
13 23<br />
13 21<br />
SMX12 11<br />
SMX22 11<br />
33 41<br />
SMX12 20<br />
SMX22 20<br />
33 43<br />
SMX12 02<br />
SMX22 02<br />
31 41<br />
SMX13 11<br />
57 65<br />
SMX15...<br />
SMX25...<br />
D1 O7<br />
U<<br />
14 24<br />
SMX20 11<br />
12 14<br />
14 22<br />
SMX23 11<br />
57 65<br />
34 42<br />
77 85<br />
34 44<br />
LMH11...<br />
13 21<br />
32 44<br />
32 42<br />
14 22<br />
31 43<br />
58 66<br />
SMX14...<br />
SMX24...<br />
LMU...<br />
D1<br />
D2<br />
O8<br />
SMX16...<br />
SMX26...<br />
LMA...<br />
C1<br />
T1<br />
T2<br />
LOAD<br />
T3<br />
T1<br />
T2<br />
LOAD<br />
U<<br />
D2<br />
C2<br />
❶ Change in event of magnetic and/or thermal tripping.<br />
❷ Change in event of magnetic tripping.<br />
NOTE: During breaker testing, contacts 57-56 and 65-66 switch only.<br />
11<br />
58 66 78 86<br />
➊ ➋<br />
31 43<br />
14 22<br />
Mounting on<br />
left side of<br />
starter.<br />
32 44<br />
13 21<br />
Mounting on<br />
right side of<br />
starter.<br />
IEC style contactors<br />
Definitive purpose contactors<br />
THREE-POLE CONTACTORS<br />
BG06 - BG09 - BGF09 - BGP09 - BG12 - DPBG12<br />
BF09A - BF12A - BF18A - BF25A - DPBF09A - DPBF12A - DPBF18A<br />
BF9C - BF12C - BF16C - BF20C - BF25C<br />
...10<br />
L1 L2 L3<br />
A1 1 3 5<br />
A2 2 4 6<br />
T1 T2 T3<br />
13<br />
14<br />
...01<br />
L1 L2 L3<br />
A1 1 3 5<br />
21(11❺)<br />
A2 2 4 6 22(12❺)<br />
T1 T2 T3<br />
➌ For BF9C-BF25C types only.<br />
BF26A - BF32A - BF38A<br />
DPBF26A - DPBF32A - BF32C<br />
BF40C - BF50 - BF110<br />
B115 - B630 1000 ➍<br />
L1 L2 L3<br />
A1 1 3 5<br />
A2 2 4 6<br />
T1 T2 T3<br />
B1250 24 - B1600 24... ➍<br />
A1<br />
A2<br />
L1 L2 L3<br />
T1 T2 T3<br />
➍ The input electronic circuit<br />
of the contactor coil is<br />
designed and tested<br />
according to IEEEC 62.41<br />
standards and can<br />
withstand a 10kV impulse<br />
voltage (1.2/50µs) with 60<br />
Joule energy. The use of<br />
an auxiliary reduced<br />
voltage transformer is<br />
recommended for higher<br />
values.<br />
FOUR-POLE CONTACTORS<br />
BG09 T4 - BGF09 T4 - BGP09 T4 - DPBG T4<br />
BF09 T4 - BF38 T4 - DPBF09 T4 - DPBF26 T4<br />
BF9C 40 - BF40C 40<br />
BF50 40 - BF65 40 - BF80 40<br />
BF65C 40 - BF80C 40<br />
B115 4 - B630 1000 4 ❹<br />
L1 L2 L3 L4<br />
A1 1 3 5 7<br />
B1250 4 - B1600 4 ➍<br />
A1<br />
A2<br />
L1 L2 L3<br />
T1 T2 T3<br />
L4<br />
T4<br />
➍ The input electronic circuit<br />
of the contactor coil is<br />
designed and tested<br />
according to IEEEC 62.41<br />
standards and can<br />
withstand a 10kV impulse<br />
voltage (1.2/50µs) with 60<br />
Joule energy. The use of<br />
an auxiliary reduced<br />
voltage transformer is<br />
recommended for higher<br />
values.<br />
A2 2 4 6<br />
T1 T2 T3<br />
8<br />
T4<br />
CONTACTORS FOR POWER FACTOR CORRECTION<br />
BFK09 A - BFK12 A - BFK18 A<br />
L1 L2 L3<br />
1 3 5<br />
BFK26 A - BFK32 A - BFK38A - BF50K - BF65K - BF70K - BF80K<br />
L1 L2 L3<br />
1 3 5<br />
A1<br />
13<br />
A1<br />
A2<br />
14<br />
A2<br />
2 4 6<br />
T1 T2 T3<br />
2 4 6<br />
T1 T2 T3<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com
electric<br />
Wiring diagrams<br />
IEC style contactors<br />
Definitive purpose contactors<br />
W-3<br />
SPECIAL FOUR-POLE CONTACTORS<br />
BG09 T2<br />
BF09 T2 A - BF18 T2 A - BF26 T2 A - BF38 T2 A<br />
BF16C 22 - BF25C 22 - BF40C 22<br />
BF18 T0 A<br />
BF16C 04 - BF25C 04<br />
A1<br />
1 R1 R3<br />
NO NC NC<br />
3<br />
NO<br />
A1<br />
R1 1 3<br />
NC NO NO<br />
R3<br />
NC<br />
A1<br />
R1 R3 R5<br />
NC NC NC<br />
R7<br />
NC<br />
W<br />
A2<br />
2<br />
R2<br />
R4<br />
4<br />
A2 R2 2<br />
4<br />
R4<br />
A2<br />
R2<br />
R4<br />
R6<br />
R8<br />
CONTROL RELAYS<br />
BG00 40 - BGF00 40<br />
BF00 40 A<br />
BG00 31 - BGF00 31<br />
BF00 31 A<br />
BG00 22 - BGF00 22<br />
BF00 22 A<br />
BF00 04 A<br />
A1 13 23<br />
33<br />
43<br />
A1 13 21<br />
33<br />
43<br />
A1 13 21<br />
31<br />
43<br />
A1 11 21<br />
31<br />
41<br />
A2 14 24<br />
34<br />
44<br />
A2 14 22<br />
34<br />
44<br />
A2 14 22<br />
32<br />
44<br />
A2 12 22<br />
32<br />
42<br />
ADD-ON BLOCKS FOR BG MINI-CONTACTORS<br />
Auxiliary contacts<br />
BGX10 02<br />
BGXF10 02<br />
BGX10 11<br />
BGXF10 11<br />
BGX10 20<br />
BGXF10 20<br />
BGX10 04<br />
BGXF10 04<br />
BGX10 13<br />
BGXF10 13<br />
BGX10 22<br />
BGXF10 22<br />
BGX10 31<br />
BGXF10 31<br />
BGX10 40<br />
BGXF10 40<br />
51 61<br />
53 61<br />
53 63<br />
51 61 71 81<br />
53 61 71 81<br />
53 63 71 81<br />
53 63 73 81<br />
53 63 73 83<br />
52 62<br />
54 62<br />
54 64<br />
52 62 72 82<br />
54 62 72 82<br />
54 64 72 82<br />
54 64 74 82<br />
54 64 74 84<br />
Surge suppressors<br />
BGX77<br />
~<br />
BGX78<br />
+<br />
BGX79<br />
~<br />
+<br />
–<br />
~<br />
--<br />
~<br />
Rigid connecting kits<br />
SMX90 21<br />
SMX90 22<br />
L1 L2<br />
A1 1 3<br />
L3<br />
5<br />
A1<br />
L1<br />
1<br />
L2<br />
3<br />
L3<br />
5<br />
A1<br />
L1<br />
1<br />
L2<br />
3<br />
L3<br />
5<br />
L1 L2<br />
A1 1 3<br />
L3<br />
5 11<br />
A1<br />
L1<br />
1<br />
L2<br />
3<br />
L3<br />
5<br />
11<br />
A2<br />
2 4 6<br />
T1 T2 T3<br />
A2<br />
2 4 6<br />
T1 T2 T3<br />
A2<br />
2 4 6<br />
T1 T2 T3<br />
A2<br />
2 4 6 12<br />
T1 T2 T3<br />
A2<br />
2 4 6<br />
T1 T2 T3<br />
12<br />
ADD-ON BLOCKS FOR BF CONTACTORS<br />
Auxiliary contacts<br />
BFX10 20<br />
BFX10 11<br />
BFX10 02<br />
G484 30<br />
G484 21<br />
G484 12<br />
G484 03<br />
53<br />
63<br />
53<br />
61<br />
51<br />
61<br />
53<br />
63<br />
73<br />
53<br />
61<br />
73<br />
53<br />
61<br />
71<br />
51<br />
61<br />
71<br />
54<br />
64<br />
54<br />
62<br />
52<br />
62<br />
54<br />
64<br />
74<br />
54<br />
62<br />
74<br />
54<br />
62<br />
72<br />
52<br />
62<br />
72<br />
BFX10 04<br />
BFX10 13<br />
BFX10 22<br />
BFX10 31<br />
BFX10 40<br />
G418 10<br />
G428 10<br />
G418 10A<br />
G428 10A<br />
G418 01<br />
G428 01<br />
G418 01A<br />
G428 01A<br />
51 61 71 81<br />
53 61 71 81<br />
53 63 71 81<br />
53 63 73 81<br />
53 63 73 83<br />
53<br />
57<br />
51<br />
55<br />
52 62 72 82<br />
54 62 72 82<br />
54 64 72 82<br />
54 64 74 82<br />
54 64 74 84<br />
54<br />
58<br />
52<br />
56<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com
W-4 Wiring diagrams<br />
IEC style contactors<br />
Definitive purpose contactors<br />
Auxiliary contacts<br />
G218<br />
electric<br />
W<br />
02<br />
91<br />
03<br />
94<br />
04<br />
93<br />
01<br />
92<br />
04<br />
93<br />
01<br />
92<br />
02<br />
91<br />
03<br />
94<br />
92<br />
01<br />
93<br />
04<br />
94<br />
03<br />
01<br />
03<br />
93 91<br />
91<br />
02<br />
94<br />
02<br />
92<br />
04<br />
The termination of the G218 auxiliary block has more than one numbering due to the fact that the block can assume various mounting positions.<br />
See the numbering in boldface and larger digits for a correct interpretation.<br />
G481 20<br />
G481 11<br />
G481 02<br />
G482<br />
G485<br />
G486 - G487<br />
BFX42<br />
BFX50 01<br />
124 114<br />
NO NO<br />
93<br />
03<br />
122 114<br />
NC NO<br />
93<br />
01<br />
122 112<br />
NC NC<br />
91<br />
01<br />
114<br />
94<br />
111<br />
91<br />
57<br />
65<br />
67<br />
55<br />
L4<br />
7<br />
131<br />
131<br />
94<br />
04<br />
123 113<br />
NO<br />
NO<br />
94<br />
02<br />
121 113<br />
NO<br />
NC<br />
92<br />
121 111<br />
NC<br />
02<br />
NC<br />
92<br />
112<br />
58<br />
66<br />
68<br />
56<br />
8<br />
T4<br />
132<br />
132<br />
Mechanical latch<br />
G222 - G272<br />
Surge suppressors<br />
G318 - BFX77<br />
G319 225<br />
G322 - BFX79<br />
A1<br />
~<br />
+<br />
~<br />
+<br />
–<br />
E1<br />
E2<br />
A2<br />
~<br />
--<br />
~<br />
Rigid connecting kits<br />
BFX31 01 - BFX32 01<br />
BFX31 11 - BFX32 11<br />
BFX31 31 - BFX32 31 - BFX32 32<br />
L1 L2<br />
A1 1 3<br />
L3<br />
5<br />
A1<br />
L1<br />
1<br />
L2<br />
3<br />
L3<br />
5<br />
L1 L2<br />
A1 1 3<br />
L3<br />
5<br />
A1<br />
L1<br />
1<br />
L2<br />
3<br />
L3<br />
5<br />
L1 L2<br />
A1 1 3<br />
L3<br />
5<br />
A1<br />
L1<br />
1<br />
L2<br />
3<br />
L3<br />
5<br />
A1<br />
L1<br />
1<br />
L2<br />
3<br />
L3<br />
5<br />
A2<br />
2 4 6<br />
T1 T2 T3<br />
A2<br />
2 4 6<br />
T1 T2 T3<br />
A2<br />
2 4 6<br />
T1 T2 T3<br />
A2<br />
2 4 6<br />
T1 T2 T3<br />
A2<br />
2 4 6<br />
T1 T2 T3<br />
A2<br />
2 4 6<br />
T1 T2 T3<br />
A2<br />
2 4 6<br />
T1 T2 T3<br />
ADD-ON BLOCKS FOR B CONTACTORS<br />
Auxiliary contacts G350 - G354<br />
G354<br />
G350<br />
G350<br />
G354<br />
41<br />
73<br />
73<br />
01<br />
42<br />
74<br />
13<br />
74<br />
13<br />
53<br />
113<br />
54<br />
114<br />
61<br />
oppure<br />
02<br />
53<br />
113<br />
54<br />
114<br />
61<br />
14<br />
93<br />
81<br />
21<br />
82<br />
22<br />
oppure<br />
14<br />
81<br />
21<br />
82<br />
22<br />
121<br />
62<br />
121<br />
62<br />
94<br />
33<br />
34<br />
122<br />
121<br />
114<br />
54<br />
113<br />
53<br />
02<br />
42<br />
01<br />
41<br />
122<br />
122<br />
34<br />
122<br />
33<br />
94<br />
62<br />
62<br />
121<br />
14<br />
22<br />
21<br />
81<br />
82<br />
oppure<br />
14<br />
21<br />
81<br />
22<br />
82<br />
93<br />
61<br />
oppure<br />
61<br />
114<br />
54<br />
113<br />
53<br />
13<br />
74<br />
73<br />
13<br />
73<br />
74<br />
G354<br />
G350<br />
G350<br />
G354<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com
electric<br />
Wiring diagrams<br />
IEC style overload relays<br />
W-5<br />
OVERLOAD RELAYS FOR BG MINI-CONTACTORS<br />
RF9 - RFN9<br />
RFS9<br />
RFA9 - RFNA9<br />
95<br />
97<br />
TEST<br />
RESET<br />
L1 L2 L3<br />
1 3 5<br />
95<br />
97<br />
TEST<br />
RESET<br />
L1 L3<br />
1 5<br />
95<br />
L1 L2 L3<br />
97 1 3 5<br />
W<br />
96<br />
98<br />
2 4 6<br />
T1 T2 T3<br />
96<br />
98<br />
2 6<br />
T1 T3<br />
96<br />
98<br />
2 4 6<br />
T1 T2 T3<br />
OVERLOAD RELAYS FOR BF CONTACTORS<br />
RF38 - RFN38<br />
RFS38<br />
RF25 - RFN25<br />
RF95 - RFN95<br />
RFS25<br />
RFS95<br />
95<br />
STOP<br />
97<br />
TEST<br />
RESET<br />
L1 L2 L3<br />
1 3 5<br />
95<br />
STOP<br />
97<br />
TEST<br />
RESET<br />
L1 L3<br />
1 5<br />
95<br />
97<br />
TEST<br />
RESET<br />
L1 L2 L3<br />
1 3 5<br />
95<br />
97<br />
TEST<br />
RESET<br />
L1 L3<br />
1 5<br />
96<br />
98<br />
2 4 6<br />
T1 T2 T3<br />
96<br />
98<br />
2 6<br />
T1 T3<br />
96<br />
98<br />
2 4 6<br />
T1 T2 T3<br />
96<br />
98<br />
2 6<br />
T1 T3<br />
RFA25<br />
RFA95<br />
RFSA25<br />
95<br />
L1 L2 L3<br />
97 1 3 5<br />
95<br />
L1 L3<br />
97 1 5<br />
96<br />
98<br />
2 4 6<br />
T1 T2 T3<br />
96<br />
98<br />
2 6<br />
T1 T3<br />
OVERLOAD RELAYS FOR B CONTACTORS<br />
RF200 - RFN200<br />
RF420 - RFN420<br />
95<br />
STOP<br />
97<br />
TEST<br />
RESET<br />
1 3 5<br />
L1 L2 L3<br />
1 3 5<br />
ADD-ON BLOCKS<br />
G228 electrical reset<br />
L1 L2 L3<br />
A1 1 3<br />
BF...<br />
5<br />
A2 2 4<br />
6<br />
96<br />
98<br />
2 4 6<br />
R<br />
TEST<br />
RESET<br />
2 4 6<br />
T1 T2 T3<br />
E1<br />
G228...<br />
95<br />
97<br />
1 3 5<br />
E2<br />
96<br />
98<br />
RF...<br />
2 4 6<br />
L<br />
L1<br />
T1 T2 T3<br />
IEC style starters<br />
REVERSING CONTACTOR ASSEMBLY<br />
BGR09<br />
BFA...42<br />
L1 L2<br />
A1 1 3<br />
L3<br />
5 21<br />
A1<br />
L1<br />
1<br />
L2<br />
3<br />
L3<br />
5<br />
21<br />
KM1<br />
KM2<br />
A2<br />
2 4 6 22<br />
T1 T2 T3<br />
A2<br />
2 4 6<br />
T1 T2 T3<br />
22<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com
W-6 Wiring diagrams<br />
IEC style starters<br />
electric<br />
FULL VOLTAGE - ACROSS THE LINE - NON REVERSING STARTERS IN NON-METALLIC ENCLOSURE<br />
W<br />
M...P<br />
I<br />
R<br />
5<br />
A1<br />
A2<br />
1<br />
95<br />
96<br />
2<br />
97<br />
98<br />
LINE<br />
L1 L2 L3<br />
1 3 5<br />
2 4 6<br />
T1 T2 T3<br />
6<br />
3<br />
4<br />
4<br />
3<br />
M...R<br />
R<br />
5<br />
A1<br />
A2<br />
1<br />
95<br />
96<br />
97<br />
98<br />
LINE<br />
L1 L2 L3<br />
1 3 5<br />
2 4 6<br />
T1 T2 T3<br />
6<br />
3<br />
4<br />
DIAGRAM 2<br />
For two-wire control, connect the<br />
N/O signal contact between<br />
terminal 3 of the contactor and<br />
terminal 95 of the overload relay.<br />
IMPORTANT<br />
-- For separate control voltage<br />
supply, remove jumpers 5 and 6<br />
and connect external control<br />
power to terminals A1 and 3.<br />
– If control circuit supply is to be<br />
line to neutral, remove jumper 5<br />
and connect the neutral to<br />
terminal A1.<br />
-- SINGLE-PHASE SUPPLY<br />
The main circuit must be<br />
configured according to Diagram<br />
3 or 4 in the case of a single<br />
phase line or motor.<br />
-- FUSES<br />
A set of fuses must be<br />
connected upstream of the<br />
starter in the event no<br />
appropriate protection is<br />
included in the system.<br />
2 4 6<br />
T1 T2 T3<br />
2 4 6<br />
T1 T2 T3<br />
LOAD<br />
Diagram 1 - Incorporated button control<br />
LOAD<br />
Diagram 2 - External button control<br />
M...R<br />
LINE<br />
LINE<br />
6<br />
5<br />
A1<br />
L1<br />
1<br />
L3<br />
5<br />
3<br />
L1 L2 L3<br />
1 3 5<br />
A2<br />
2<br />
T1<br />
6<br />
T3<br />
4<br />
2 4 6<br />
T1 T2 T3<br />
1<br />
95<br />
97<br />
R<br />
96<br />
98<br />
2 6<br />
T1 T3<br />
2 4 6<br />
T1 T2 T3<br />
LOAD<br />
Diagram 3 - Power connection for 1-phase motors<br />
(type c/w RFS overload relay)<br />
LOAD<br />
Diagram 4 - Power connection<br />
for 1-phase motors (type c/w RF overload relay)<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com
electric<br />
Wiring diagrams<br />
Limit, micro and foot switches<br />
W-7<br />
K...S11<br />
Snap<br />
TS...<br />
Snap<br />
K...L11<br />
Slow<br />
K...L02<br />
Slow<br />
K...S02<br />
Snap<br />
K...L20<br />
Slow<br />
K...A11<br />
Slow<br />
21 13<br />
13 21<br />
21 13<br />
11 21<br />
11 21<br />
13 23<br />
17 25<br />
W<br />
22 14<br />
1NO + 1NC<br />
14 22<br />
1NO + 1NC<br />
22 14<br />
1NO + 1NC<br />
12 22<br />
2NC<br />
12 22<br />
2NC<br />
14 24<br />
2NO<br />
18 26<br />
1NO + 1NC<br />
make before break<br />
K...L03<br />
Slow<br />
K...L12<br />
Slow<br />
K...L21<br />
Slow<br />
RS13...<br />
TL13<br />
KP<br />
KS<br />
11<br />
21 31<br />
13<br />
21 31<br />
13<br />
23 31<br />
BLACK BROWN<br />
2 NC 3 NO<br />
13 14<br />
GREEN/YELLOW<br />
12<br />
22 32<br />
3NC<br />
14<br />
22 32<br />
1NO + 2NC<br />
14<br />
24 32<br />
2NO + 1NC<br />
BLACK<br />
BLUE<br />
1 COM<br />
21 22<br />
Rotary cam switches - Circuit schemes<br />
90 - One-pole ON/OFF switch 91 - Two-pole ON/OFF switch 10 - Three-pole ON/OFF switch<br />
0<br />
0<br />
0<br />
1<br />
1<br />
1<br />
92 - Four-pole ON/OFF switch 51 - 1-pole double throw<br />
switch with 0<br />
0<br />
1<br />
1<br />
0 0 2<br />
1 2<br />
52 - 2-pole double throw<br />
switch with 0<br />
Number of wafers: 1<br />
Switching angle: 60°<br />
Number of wafers: 1<br />
Switching angle: 60°<br />
Number of wafers: 2<br />
Switching angle: 60°<br />
Number of wafers: 2<br />
Switching angle: 60°<br />
Number of wafers: 1<br />
Switching angle: 60°<br />
Number of wafers: 2<br />
Switching angle: 60°<br />
53 - 3-pole double throw switch<br />
with 0<br />
75 - 4-pole double throw switch<br />
with 0<br />
1<br />
0 0 2<br />
1<br />
2<br />
2<br />
54 - 1-pole double throw<br />
without 0<br />
1<br />
55 - 2-pole double throw<br />
without 0<br />
1<br />
2<br />
56 - 3-pole double throw<br />
without 0<br />
1<br />
2<br />
Number of wafers: 3<br />
Switching angle: 60°<br />
Number of wafers: 4<br />
Switching angle: 60°<br />
Number of wafers: 1<br />
Switching angle: 90°<br />
Number of wafers: 2<br />
Switching angle: 90°<br />
Number of wafers: 3<br />
Switching angle: 90°<br />
69 - 4-pole double throw without 0<br />
11 - 3-pole reversing switch<br />
13 - Pole-changing switch with 0 (Dahlander)<br />
1<br />
2<br />
1<br />
0 0 2<br />
1 2<br />
Number of wafers: 4<br />
Switching angle: 90°<br />
12 - Wye-delta switch<br />
Number of wafers: 3<br />
Switching angle: 60°<br />
Number of wafers: 4<br />
Switching angle: 60°<br />
26 - Reversing switch, spring return to 0<br />
Y<br />
0<br />
0<br />
∆<br />
1<br />
0 2<br />
Number of wafers: 4<br />
Switching angle: 60°<br />
Number of wafers: 3<br />
Switching angle: 30°<br />
20 - Pole-changing switch with reversing (Dahlander)<br />
1<br />
1<br />
2 2<br />
Number of wafers: 6<br />
Switching angle: 30°<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com
W-8 Wiring diagrams<br />
Rotary cam switches. Circuit schemes<br />
electric<br />
97 - Ammeter switch direct reading or via current transformer 68 - Phase-neutral voltmeter switch 67 - Phase-phase voltmeter switch<br />
L3<br />
0<br />
L1<br />
0<br />
L1N<br />
L2N<br />
L3N<br />
0<br />
L1-L2<br />
L2-L3<br />
L3-L1<br />
W<br />
L2<br />
Number of wafers: 5<br />
Switching angle: 90°<br />
Number of wafers: 2<br />
Switching angle: 30°<br />
Number of wafers: 2<br />
Switching angle: 30°<br />
66 - Phase-phase phase-neutral<br />
voltmeter changeover<br />
60 - Double throw switch 1 phase<br />
phase-neutral, 3 phase-phase voltages<br />
98 - L1-L2-L3 current double throw switch<br />
L1-L2<br />
0<br />
L1-N<br />
L2-L3<br />
L2-N<br />
L3-L1<br />
L3-N<br />
0<br />
L1N L1-L2<br />
0<br />
L2-L3<br />
L3-L1<br />
L3<br />
L2<br />
L1<br />
Number of wafers: 3<br />
Switching angle: 30°<br />
Number of wafers: 3<br />
Switching angle: 30°<br />
Number of wafers: 3<br />
Switching angle: 90°<br />
Timers<br />
TM P<br />
A1 15<br />
On delay. Delay on make, with<br />
start at relay energizing.<br />
A1<br />
A2<br />
ON<br />
A2 16 18<br />
18<br />
15<br />
16<br />
t<br />
TM M1<br />
On delay. Delay on make, with<br />
start at relay energizing<br />
A1<br />
A2<br />
ON<br />
Pulse on relay energizing with start<br />
at external contact closing<br />
A1<br />
A2<br />
ON<br />
S<br />
A1 S<br />
15<br />
C<br />
B<br />
A<br />
D E F G<br />
J<br />
H<br />
I<br />
18<br />
15<br />
16<br />
t<br />
C<br />
B<br />
A<br />
D E F G<br />
J<br />
H<br />
I<br />
S<br />
18<br />
15<br />
16<br />
t<br />
t<br />
A2 16 18<br />
Pulse on relay energising with<br />
start on energizing<br />
A1<br />
A2<br />
ON<br />
Pulse on relay energizing with start<br />
at external contact opening<br />
A1<br />
A2<br />
ON<br />
C<br />
B<br />
A<br />
D E F G<br />
J<br />
H<br />
I<br />
18<br />
15<br />
16<br />
t<br />
C<br />
B<br />
A<br />
D E F G<br />
J<br />
H<br />
I<br />
S<br />
18<br />
15<br />
16<br />
t<br />
t<br />
Flasher, starting with OFF (pause)<br />
interval. Equal timing recycle.<br />
C<br />
B<br />
A<br />
D E F G<br />
J<br />
H<br />
I<br />
A1<br />
A2<br />
ON<br />
18<br />
15<br />
16<br />
t<br />
(pause)<br />
t t t<br />
(work) (pause) (work)<br />
On-Off delay. Delay on make, with<br />
start at external contact closing, and<br />
delay at break, with start at external<br />
contact opening.<br />
C<br />
B<br />
A<br />
D E F G<br />
J<br />
H<br />
I<br />
A1<br />
A2<br />
ON<br />
S<br />
18<br />
15<br />
16<br />
t<br />
t t t<br />
Flasher, starting with ON (work)<br />
interval. Equal timing recycle.<br />
ON<br />
A1<br />
A2<br />
Step relay at each closing of an<br />
external contact.<br />
A1<br />
A2<br />
ON<br />
C<br />
B<br />
A<br />
D E F G<br />
J<br />
H<br />
I<br />
18<br />
15<br />
16<br />
t t t t<br />
(work) (pause) (work) (pause)<br />
C<br />
B<br />
A<br />
D E F G<br />
J<br />
H<br />
I<br />
S<br />
18<br />
15<br />
16<br />
Off delay. Relay energising at<br />
external contact closing with start<br />
on break<br />
A1<br />
A2<br />
ON<br />
Pulse generator. Unequal timing<br />
recycle, starting with OFF pulse time<br />
and 0.5sec ON time.<br />
A1<br />
A2<br />
ON<br />
D E F G<br />
C<br />
H<br />
B<br />
I<br />
A J<br />
S<br />
18<br />
15<br />
16<br />
t<br />
D E F G<br />
C<br />
H<br />
B<br />
I<br />
A J<br />
18<br />
15<br />
16<br />
t<br />
0,5s<br />
t<br />
0,5s<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com
electric<br />
Wiring diagrams<br />
Timers<br />
W-9<br />
TM M2<br />
S<br />
With instantaneous operation<br />
programmed<br />
S<br />
With delayed operation programmed<br />
A1 S 15<br />
23<br />
A1 S 15<br />
27<br />
W<br />
INST<br />
DEL<br />
A2 16 18<br />
24<br />
A2 16 18<br />
28<br />
On delay. Delay on make, with start<br />
at relay energizing<br />
Pulse on relay energising with start on<br />
energizing<br />
On delay. Delay on make, with start<br />
at relay energizing<br />
Pulse on relay energising with start on<br />
energizing<br />
ON<br />
A1<br />
A2<br />
18<br />
C<br />
B<br />
A<br />
D E F G<br />
J<br />
H<br />
I<br />
ON<br />
A1<br />
A2<br />
18<br />
15<br />
16<br />
C<br />
B<br />
A<br />
D E F G<br />
J<br />
H<br />
I<br />
ON<br />
A1<br />
A2<br />
18<br />
C<br />
B<br />
A<br />
D E F G<br />
J<br />
H<br />
I<br />
ON<br />
A1<br />
A2<br />
18<br />
15<br />
16<br />
C<br />
B<br />
A<br />
D E F G<br />
J<br />
H<br />
I<br />
15<br />
16<br />
23<br />
24<br />
t<br />
Flasher, starting with OFF (pause)<br />
interval. Equal timing recycle<br />
23<br />
24<br />
t<br />
Flasher, starting with ON (work) interval.<br />
Equal timing recycle<br />
15<br />
16<br />
27<br />
28<br />
t<br />
Flasher, starting with OFF (pause)<br />
interval. Equal timing recycle<br />
27<br />
28<br />
t<br />
Flasher, starting with ON (work) interval.<br />
Equal timing recycle<br />
ON<br />
A1<br />
A2<br />
18<br />
C<br />
B<br />
A<br />
D E F G<br />
J<br />
H<br />
I<br />
ON<br />
A1<br />
A2<br />
18<br />
C<br />
B<br />
A<br />
D E F G<br />
J<br />
H<br />
I<br />
ON<br />
A1<br />
A2<br />
18<br />
15<br />
16<br />
C<br />
B<br />
A<br />
D E F G<br />
J<br />
H<br />
I<br />
ON<br />
A1<br />
A2<br />
18<br />
15<br />
16<br />
C<br />
B<br />
A<br />
D E F G<br />
J<br />
H<br />
I<br />
15<br />
16<br />
15<br />
16<br />
23<br />
24<br />
t<br />
(pause)<br />
t<br />
(work)<br />
t<br />
(pause)<br />
t<br />
(work)<br />
23<br />
24<br />
t<br />
(work)<br />
t<br />
(pause)<br />
t<br />
(work)<br />
t<br />
(pause)<br />
27<br />
28<br />
t<br />
(pause)<br />
t<br />
(work)<br />
t<br />
(pause)<br />
t<br />
(work)<br />
27<br />
28<br />
t<br />
(work)<br />
t<br />
(pause)<br />
t<br />
(work)<br />
t<br />
(pause)<br />
Off delay. Relay energizing at external<br />
contact closing with start on break<br />
Pulse on relay energizing with start on<br />
external contact closing<br />
Off delay. Relay energizing at external<br />
contact closing with start on break<br />
Pulse on relay energizing with start on<br />
external contact closing<br />
ON<br />
A1<br />
A2<br />
ON<br />
A1<br />
A2<br />
ON<br />
A1<br />
A2<br />
ON<br />
A1<br />
A2<br />
S<br />
18<br />
15<br />
16<br />
23<br />
24<br />
t<br />
C<br />
B<br />
A<br />
D E F G<br />
J<br />
H<br />
I<br />
S<br />
18<br />
15<br />
16<br />
23<br />
24<br />
t<br />
t<br />
C<br />
B<br />
A<br />
D E F G<br />
J<br />
H<br />
I<br />
S<br />
18<br />
15<br />
16<br />
27<br />
28<br />
t<br />
C<br />
B<br />
A<br />
D E F G<br />
J<br />
H<br />
I<br />
S<br />
18<br />
15<br />
16<br />
27<br />
28<br />
t<br />
t<br />
C<br />
B<br />
A<br />
D E F G<br />
J<br />
H<br />
I<br />
Pulse on relay energizing with start<br />
on external contact opening<br />
On-off delay. Delay make, with start at<br />
external contact closing and delay at<br />
break, with start at external contact<br />
opening<br />
Pulse on relay energizing with start<br />
on external contact opening<br />
On-off delay. Delay make, with start at<br />
external contact closing and delay at<br />
break, with start at external contact<br />
opening<br />
ON<br />
A1<br />
A2<br />
ON<br />
A1<br />
A2<br />
ON<br />
A1<br />
A2<br />
ON<br />
A1<br />
A2<br />
S<br />
D E F G<br />
C<br />
H<br />
B<br />
I<br />
A J<br />
S<br />
D E F G<br />
C<br />
H<br />
B<br />
I<br />
A J<br />
S<br />
D E F G<br />
C<br />
H<br />
B<br />
I<br />
A J<br />
S<br />
D E F G<br />
C<br />
H<br />
B<br />
I<br />
A J<br />
18<br />
18<br />
18<br />
18<br />
15<br />
16<br />
23<br />
24<br />
t<br />
t<br />
15<br />
16<br />
23<br />
24<br />
t<br />
t t t<br />
15<br />
16<br />
27<br />
28<br />
t<br />
t<br />
15<br />
16<br />
27<br />
28<br />
t<br />
t t t<br />
Step relay at each closing of an external<br />
contact<br />
Pulse generator. Unequal timing recycle,<br />
starting with ON pulse time<br />
Step relay at each closing of an external<br />
contact<br />
Pulse generator. Unequal timing recycle,<br />
starting with ON pulse time<br />
ON<br />
A1<br />
A2<br />
ON<br />
A1<br />
A2<br />
ON<br />
A1<br />
A2<br />
ON<br />
A1<br />
A2<br />
S<br />
D E F G<br />
C<br />
H<br />
B<br />
I<br />
A J<br />
S<br />
D E F G<br />
C<br />
H<br />
B<br />
I<br />
A J<br />
S<br />
D E F G<br />
C<br />
H<br />
B<br />
I<br />
A J<br />
S<br />
D E F G<br />
C<br />
H<br />
B<br />
I<br />
A J<br />
18<br />
15<br />
16<br />
18<br />
15<br />
16<br />
18<br />
18<br />
15<br />
16<br />
23<br />
24<br />
23<br />
24<br />
t<br />
0,5s t 0,5s<br />
15<br />
16<br />
27<br />
28<br />
27<br />
28<br />
t<br />
0,5s t 0,5s<br />
TM PL<br />
A1 S 15<br />
Flasher, starting with<br />
ON interval. Equal<br />
timing recycle, ON first<br />
ON<br />
A1<br />
A2<br />
Flasher, starting with<br />
OFF interval. Equal<br />
timing recycle, OFF first<br />
ON<br />
A1<br />
A2<br />
TM D<br />
A1 15<br />
True off delay. Delay on break, starting<br />
at relay de-energising<br />
ON<br />
A1<br />
A2<br />
A2 16 18<br />
S-A1<br />
18<br />
15<br />
16<br />
W<br />
P<br />
W<br />
P<br />
S-A1<br />
18<br />
15<br />
16<br />
P<br />
W<br />
P<br />
W<br />
A2 16 18 18<br />
15<br />
16<br />
t<br />
W = Work / On<br />
P = Pause / Off<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com
W-10 Wiring diagrams<br />
Timers<br />
electric<br />
TM LS<br />
Staircase lighting<br />
TM ST<br />
For starting<br />
W<br />
L<br />
N<br />
N 3<br />
L 4<br />
L<br />
N<br />
ON<br />
L/N<br />
3<br />
L<br />
4<br />
t t 1h<br />
>3s >3s >3s<br />
A1 17<br />
A2<br />
18 28<br />
A1<br />
A2<br />
ON<br />
18<br />
17<br />
28<br />
17<br />
start<br />
transition<br />
N 3<br />
L<br />
N<br />
ON<br />
L<br />
N<br />
L 4<br />
L<br />
4<br />
AT1P<br />
AT1CP<br />
ATD<br />
220-440VAC<br />
100-240VAC<br />
24VAC<br />
On delay. Delay on make, with<br />
start at relay energizing<br />
24VAC/DC<br />
110-125VAC/DC<br />
12VAC/DC<br />
48-60VAC/DC<br />
On delay. Delay on make, with<br />
start at relay energizing<br />
24VAC/DC<br />
48VAC/DC<br />
110-127VAC<br />
220-240VAC<br />
True off delay. Delay on break, starting at<br />
relay de-energizing<br />
A1 A3 15<br />
ON<br />
RELAY<br />
A.<br />
A2<br />
18<br />
15<br />
16<br />
t<br />
A1 A3 15<br />
ON<br />
RELAY<br />
A.<br />
A2<br />
18<br />
15<br />
16<br />
t<br />
A1 15<br />
ON<br />
RELAY<br />
A1<br />
A2<br />
18<br />
15<br />
16<br />
t<br />
A2 16 18<br />
A2 16 18<br />
A2 16 18<br />
AT1DP<br />
24VAC/DC<br />
48VAC/DC<br />
110-127VAC<br />
220-240VAC<br />
Off delay. Relay energizing at external contact closing.<br />
Delay at break, with start at de-engerzing, auxiliary supply<br />
❶<br />
A1 B1 15<br />
A2 16 18<br />
ON<br />
RELAY<br />
A1<br />
A2<br />
B1<br />
18<br />
15<br />
16<br />
> 25ms<br />
t<br />
❶ B1 terminal must be simultaneously supplied<br />
with terminal A1 or there after.<br />
CAUTION: With DC supply, the “-” polarity must be<br />
connected to A2 terminal.<br />
BTPM1<br />
On delay. Delay on make, with start at relay<br />
energizing<br />
Pulse on relay energizing with start when<br />
energized<br />
ON<br />
A.<br />
A2<br />
RELAY<br />
18<br />
15 16<br />
t<br />
ON<br />
8<br />
7<br />
6<br />
5<br />
4<br />
3<br />
2<br />
1<br />
ON<br />
A.<br />
A2<br />
RELAY<br />
18<br />
15<br />
16<br />
t<br />
ON<br />
8<br />
7<br />
6<br />
5<br />
4<br />
3<br />
2<br />
1<br />
220-240VAC<br />
110-127VAC<br />
24VAC/DC<br />
On delay. Delay on make with start at<br />
external contact opening<br />
Off delay. Relay energizing at external<br />
contact opening<br />
A1<br />
A3<br />
A4<br />
15<br />
A2 16 18<br />
R1<br />
R2<br />
C❷<br />
ON<br />
A.<br />
A2<br />
RELAY<br />
18<br />
15<br />
16<br />
R1<br />
C❶<br />
R2<br />
t<br />
t<br />
t<br />
ON<br />
8<br />
7<br />
6<br />
5<br />
4<br />
3<br />
2<br />
1<br />
ON<br />
A.<br />
A2<br />
RELAY<br />
18<br />
15<br />
16<br />
R1<br />
C❶<br />
R2<br />
t<br />
t<br />
t<br />
ON<br />
8<br />
7<br />
6<br />
5<br />
4<br />
3<br />
2<br />
1<br />
60VAC/DC<br />
48VAC/DC<br />
24VAC/DC<br />
Flasher<br />
Starting with OFF interval.<br />
Equal timing<br />
Starting with ON interval.<br />
Equal timing<br />
A1<br />
A3<br />
A4<br />
15<br />
A2 16 18<br />
R1<br />
R2<br />
C❷<br />
ON<br />
A.<br />
A2<br />
RELAY<br />
18<br />
15 16<br />
ON<br />
8<br />
7<br />
6<br />
5<br />
4<br />
3<br />
2<br />
1<br />
ON<br />
A.<br />
A2<br />
RELAY<br />
18<br />
15<br />
16<br />
ON<br />
8<br />
7<br />
6<br />
5<br />
4<br />
3<br />
2<br />
1<br />
t<br />
t t t<br />
t<br />
t<br />
t<br />
t<br />
❷ “C” contact must be volt free (dry).<br />
Flasher at external contact<br />
“C” opening<br />
Starting with OFF interval.<br />
Equal timing<br />
Starting with ON interval.<br />
Equal timing<br />
ON<br />
A.<br />
A2<br />
RELAY<br />
18<br />
15 16<br />
C❶<br />
R1<br />
R2<br />
t<br />
t<br />
t<br />
ON<br />
8<br />
7<br />
6<br />
5<br />
4<br />
3<br />
2<br />
1<br />
ON<br />
A.<br />
A2<br />
RELAY<br />
18<br />
15<br />
16<br />
R1<br />
C❶<br />
R2<br />
t<br />
t<br />
t<br />
ON<br />
8<br />
7<br />
6<br />
5<br />
4<br />
3<br />
2<br />
1<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com
electric<br />
Wiring diagrams<br />
Timers<br />
W-11<br />
BTPM<br />
220-240VAC<br />
110-127VAC<br />
24VAC/DC<br />
On delay. Delay<br />
on make,<br />
with start at<br />
relay energizing<br />
2 SPDT contact, both delayed 1 instantaneous SPDT contact +<br />
1 delayed SPDT contact<br />
ON<br />
RELAY<br />
25<br />
A.<br />
A2<br />
18<br />
15<br />
16<br />
28<br />
26<br />
t<br />
ON<br />
8<br />
7<br />
6<br />
5<br />
4<br />
3<br />
2<br />
1<br />
ON<br />
RELAY<br />
15<br />
A.<br />
A2<br />
18<br />
16<br />
24<br />
21<br />
22<br />
t<br />
ON<br />
8<br />
7<br />
6<br />
5<br />
4<br />
3<br />
2<br />
1<br />
W<br />
A1 A3 A4 25<br />
15<br />
A2 26 28 16 18<br />
R1<br />
R2<br />
C❶<br />
Pulse on relay<br />
energising<br />
with start<br />
when<br />
energized<br />
ON<br />
RELAY<br />
A.<br />
A2<br />
18<br />
15<br />
16<br />
28<br />
25<br />
26<br />
t<br />
ON<br />
8<br />
7<br />
6<br />
5<br />
4<br />
3<br />
2<br />
1<br />
ON<br />
RELAY<br />
21<br />
A.<br />
A2<br />
18<br />
15<br />
16<br />
24<br />
22<br />
t<br />
ON<br />
8<br />
7<br />
6<br />
5<br />
4<br />
3<br />
2<br />
1<br />
60VAC/DC<br />
48VAC/DC<br />
24VAC/DC<br />
A1 A3 A4 25<br />
15<br />
A2 26 28 16 18<br />
R1<br />
R2<br />
C❶<br />
On delay.<br />
Delay on<br />
make with<br />
start at<br />
external<br />
contact<br />
opening<br />
ON<br />
RELAY<br />
25<br />
C❶<br />
A.<br />
A2<br />
18<br />
15<br />
16<br />
28<br />
26<br />
R1<br />
R2<br />
t<br />
t<br />
t<br />
ON<br />
8<br />
7<br />
6<br />
5<br />
4<br />
3<br />
2<br />
1<br />
ON<br />
RELAY<br />
15<br />
C❶<br />
A.<br />
A2<br />
18<br />
16<br />
24<br />
21<br />
22<br />
R1<br />
R2<br />
t<br />
t<br />
t<br />
ON<br />
8<br />
7<br />
6<br />
5<br />
4<br />
3<br />
2<br />
1<br />
A1<br />
A1<br />
Time range setting (t DELAY)<br />
ON<br />
8<br />
7<br />
6<br />
5<br />
4<br />
3<br />
2<br />
1<br />
0.3-3sec<br />
ON<br />
8<br />
7<br />
6<br />
5<br />
4<br />
3<br />
2<br />
1<br />
0.3-3min<br />
220-240VAC<br />
A3<br />
A2<br />
110-127VAC<br />
A4<br />
60VAC/DC<br />
A3<br />
A2<br />
24VAC/DC<br />
48VAC/DC<br />
A4<br />
ON<br />
8<br />
7<br />
6<br />
5<br />
4<br />
3<br />
2<br />
1<br />
1.2-12sec<br />
ON<br />
22<br />
24VAC/DC<br />
22<br />
8<br />
7<br />
6<br />
5<br />
4<br />
3<br />
2<br />
1<br />
1.2-12min<br />
21<br />
21<br />
24<br />
24<br />
ON<br />
8<br />
7<br />
6<br />
5<br />
4<br />
3<br />
2<br />
1<br />
9.6-96sec<br />
ON<br />
15<br />
8<br />
7<br />
6<br />
5<br />
4<br />
3<br />
2<br />
1<br />
9.6-96min<br />
16 18<br />
15<br />
16 18<br />
ON<br />
8<br />
7<br />
6<br />
5<br />
4<br />
3<br />
2<br />
1<br />
76.8-768sec<br />
ON<br />
R1<br />
R2<br />
R1<br />
R2<br />
8<br />
7<br />
6<br />
5<br />
4<br />
3<br />
2<br />
1<br />
76.8-768min<br />
C❶<br />
C❶<br />
Off delay.<br />
Delay at<br />
break,<br />
with start<br />
at external<br />
contact<br />
opening<br />
Flasher<br />
ON<br />
RELAY<br />
Flasher at<br />
external contact<br />
“C” opening<br />
A.<br />
A2<br />
18<br />
15<br />
16<br />
28<br />
25 26<br />
C❶<br />
R1<br />
R2<br />
Starting with<br />
OFF interval.<br />
Equal timing<br />
Starting with<br />
ON interval.<br />
Equal timing<br />
Starting with<br />
OFF interval.<br />
Equal timing<br />
Starting with<br />
ON interval.<br />
Equal timing<br />
t<br />
ON<br />
RELAY<br />
ON<br />
RELAY<br />
ON<br />
RELAY<br />
ON<br />
RELAY<br />
25<br />
A.<br />
A2<br />
18<br />
15<br />
16<br />
28<br />
26<br />
A.<br />
A2<br />
18<br />
15<br />
16<br />
28<br />
25<br />
26<br />
25<br />
A.<br />
A2<br />
18<br />
15<br />
16<br />
C❶<br />
28<br />
26<br />
R1<br />
R2<br />
A.<br />
A2<br />
18<br />
15<br />
16<br />
28<br />
25<br />
26<br />
t<br />
t<br />
t<br />
t t t<br />
t<br />
t<br />
t<br />
t<br />
t<br />
t<br />
t<br />
ON<br />
ON<br />
8<br />
7<br />
6<br />
5<br />
4<br />
3<br />
2<br />
1<br />
ON<br />
ON<br />
ON<br />
8<br />
7<br />
6<br />
5<br />
4<br />
3<br />
2<br />
1<br />
8<br />
7<br />
6<br />
5<br />
4<br />
3<br />
2<br />
1<br />
8<br />
7<br />
6<br />
5<br />
4<br />
3<br />
2<br />
1<br />
8<br />
7<br />
6<br />
5<br />
4<br />
3<br />
2<br />
1<br />
ON<br />
RELAY<br />
C❶<br />
21<br />
A.<br />
A2<br />
18<br />
15 16<br />
24<br />
22<br />
R1<br />
R2<br />
t<br />
ON<br />
RELAY<br />
ON<br />
RELAY<br />
ON<br />
RELAY<br />
ON<br />
RELAY<br />
15<br />
A.<br />
A2<br />
18<br />
16<br />
24<br />
21<br />
22<br />
21<br />
A.<br />
A2<br />
18<br />
15<br />
16<br />
24<br />
22<br />
A.<br />
A2<br />
18<br />
15<br />
16<br />
24<br />
21<br />
22<br />
C❶<br />
21<br />
R1<br />
R2<br />
A.<br />
A2<br />
18<br />
15<br />
16<br />
24<br />
22<br />
t<br />
t<br />
t<br />
t t t t<br />
t<br />
t<br />
t<br />
t<br />
t<br />
t<br />
ON<br />
8<br />
7<br />
6<br />
5<br />
4<br />
3<br />
2<br />
1<br />
ON<br />
8<br />
7<br />
6<br />
5<br />
4<br />
3<br />
2<br />
1<br />
ON<br />
8<br />
7<br />
6<br />
5<br />
4<br />
3<br />
2<br />
1<br />
ON<br />
8<br />
7<br />
6<br />
5<br />
4<br />
3<br />
2<br />
1<br />
ON<br />
8<br />
7<br />
6<br />
5<br />
4<br />
3<br />
2<br />
1<br />
❶ “C” contact must be volt free (dry).<br />
C❶<br />
R1<br />
R2<br />
t<br />
t<br />
t<br />
R1<br />
C❶<br />
R2<br />
t<br />
t<br />
t<br />
DRPL<br />
220-240VAC<br />
110-127VAC<br />
24VAC/DC<br />
A1 A3 A4 15 25<br />
A2 16 18 26 28 S1 S2<br />
Time range setting (t DELAY)<br />
1<br />
Flasher, starting with OFF interval.<br />
Independent timing<br />
ON<br />
ON<br />
WORK<br />
1<br />
ON<br />
25<br />
A.<br />
A2<br />
18<br />
15 16<br />
28<br />
26<br />
1<br />
ON<br />
t1 t2 t1 t2<br />
1<br />
ON<br />
1<br />
ON<br />
1<br />
ON<br />
Inizio pausa<br />
S1<br />
S2<br />
1<br />
ON<br />
Flasher, starting with ON interval.<br />
Independent timing<br />
1<br />
ON<br />
ON<br />
WORK<br />
1<br />
15<br />
ON<br />
A.<br />
A2<br />
18<br />
16<br />
28<br />
25 26<br />
1<br />
ON<br />
t2<br />
1<br />
t1<br />
ON<br />
t2<br />
1<br />
t1<br />
ON<br />
Inizio lavoro<br />
S1<br />
S2<br />
BT2N<br />
For starting<br />
48VAC/DC<br />
110-127VAC<br />
220-240VAC<br />
380-415VAC<br />
415-440VAC<br />
24VAC/DC<br />
A1 A3 15<br />
A2 16 18<br />
26<br />
25<br />
28<br />
ON<br />
RELAY<br />
A.<br />
A2<br />
18<br />
15 16<br />
28<br />
25<br />
26<br />
start<br />
transition<br />
2<br />
2<br />
2<br />
2<br />
2<br />
2<br />
2<br />
2<br />
2<br />
2<br />
2<br />
2<br />
3<br />
4<br />
3<br />
4<br />
3<br />
4<br />
3<br />
4<br />
3<br />
4<br />
3<br />
4<br />
3<br />
4<br />
3<br />
4<br />
3<br />
4<br />
3<br />
4<br />
3<br />
4<br />
3<br />
4<br />
5<br />
5<br />
5<br />
5<br />
5<br />
5<br />
5<br />
5<br />
5<br />
5<br />
5<br />
5<br />
6<br />
7<br />
6<br />
7<br />
6<br />
7<br />
6<br />
7<br />
6<br />
7<br />
6<br />
7<br />
6<br />
7<br />
6<br />
7<br />
6<br />
7<br />
6<br />
7<br />
6<br />
7<br />
6<br />
7<br />
8<br />
8<br />
8<br />
8<br />
8<br />
8<br />
8<br />
8<br />
8<br />
8<br />
8<br />
8<br />
0.3-3s<br />
0.6-6s<br />
1.2-12s<br />
3-30s<br />
6-60s<br />
12-120s 0.3-3min 0.6-6min 1.2-12min 3-30min 6-60min 12-120min<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com
W-12 Wiring diagrams<br />
Timers<br />
electric<br />
L48TP...<br />
L48TPB...<br />
110VAC<br />
220VAC<br />
24VAC<br />
24VAC/DC<br />
110VAC<br />
240VAC<br />
24VAC/DC<br />
110VAC<br />
240VAC<br />
W<br />
ON<br />
RELAY<br />
8<br />
1 2 4 8<br />
7 5 6<br />
On delay<br />
2<br />
7<br />
6<br />
5<br />
t<br />
ON<br />
RELAY<br />
1<br />
8<br />
2<br />
7<br />
3<br />
4<br />
6<br />
5<br />
2 1<br />
7 4 3<br />
On delay<br />
t<br />
8<br />
5 6<br />
B<br />
A<br />
DIP-SWITCH<br />
ON<br />
RELAY<br />
1<br />
8<br />
2<br />
7<br />
3<br />
4<br />
6<br />
5<br />
2 1<br />
7 4 3<br />
8<br />
5 6<br />
B<br />
A<br />
DIP-SWITCH<br />
On delay with one instantaneous<br />
SPDT contact and one late-break<br />
SPDT contact<br />
L48M...<br />
24÷240VAC/DC<br />
2 1<br />
On delay<br />
1<br />
0<br />
11<br />
F<br />
5<br />
6<br />
M<br />
R<br />
T (preset time) = T1+T2<br />
❶ Contacts “M” and “R” are to be volt free (dry).<br />
F<br />
F<br />
F<br />
DIP SWITCH 1 DIP SWITCH 1 DIP SWITCH 1 DIP SWITCH<br />
Pulse on relay 0<br />
Flasher<br />
0<br />
Flasher<br />
0<br />
energizing with start on energizing<br />
starting with OFF<br />
starting with ON<br />
ON<br />
2<br />
10<br />
MEMORY<br />
5<br />
7<br />
6<br />
RESET<br />
7<br />
9<br />
RELAY 11<br />
8<br />
3<br />
1<br />
4<br />
T<br />
M<br />
R<br />
T1 T2<br />
2<br />
ON<br />
10<br />
MEMORY 5<br />
7<br />
RESET<br />
6<br />
7<br />
9<br />
RELAY 11<br />
8<br />
3<br />
1<br />
4<br />
M<br />
R<br />
T1 T2 T<br />
ON<br />
2<br />
10<br />
5<br />
MEMORY<br />
7<br />
6<br />
RESET<br />
7<br />
9<br />
RELAY 11<br />
8<br />
3<br />
1<br />
4<br />
T<br />
T<br />
T<br />
M<br />
T<br />
R<br />
T<br />
T<br />
ON<br />
2<br />
10<br />
MEMORY 5<br />
7<br />
6<br />
RESET<br />
7<br />
9<br />
RELAY 11<br />
8<br />
3<br />
1<br />
4<br />
M<br />
R<br />
T<br />
T<br />
T T T<br />
T<br />
T<br />
Protection relays<br />
Voltage monitoring for single-phase systems<br />
PMV55<br />
A1<br />
Reset delay<br />
MAX Delay<br />
Reset delay<br />
MIN Delay<br />
Reset delay<br />
A2<br />
A1 A2<br />
TRMS<br />
Set up V MAX<br />
Hysteresis<br />
14<br />
12 11<br />
Hysteresis<br />
Set up V MIN<br />
V MAX<br />
V MIN<br />
ON<br />
Relay<br />
14<br />
11<br />
12<br />
A1 - A2<br />
Voltage monitoring for three-phase systems<br />
PMV10 - PMV20 - PMV30 - PMV40<br />
PMV50 - PMV60 - PMV70<br />
L1<br />
L2<br />
L3<br />
Phase loss and phase sequence (PMV10 - PMV20 - PMV30 - PMV40 - PMV50 - PMV60 - PMV70)<br />
Reset delay<br />
Reset delay<br />
Reset delay<br />
L1<br />
L2<br />
L2<br />
L1<br />
L3<br />
L3<br />
L1 L2 L3<br />
TRMS<br />
14 12 11<br />
ON<br />
MAX<br />
MIN<br />
ASYMMETRY<br />
11<br />
14<br />
12<br />
ON<br />
MAX<br />
MIN<br />
ASYMMETRY<br />
14<br />
11<br />
12<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com
electric<br />
Wiring diagrams<br />
Protection relays<br />
W-13<br />
Voltage monitoring for three-phase systems<br />
PMV30 - PMV40<br />
PMV50 - PMV60 - PMV70<br />
L1<br />
L2<br />
L3<br />
L1<br />
L2 L3<br />
TRMS<br />
High and low voltage (PMV30 - PMV50 - PMV60 - PMV70)<br />
Reset delay MAX Delay Reset delay MIN Delay Reset delay<br />
Set up V MAX<br />
Hysteresis<br />
Hysteresis<br />
Set up V MIN<br />
L1 - L2 - L3<br />
W<br />
14<br />
12 11<br />
ON<br />
V MAX<br />
V MIN<br />
14<br />
11<br />
12<br />
Asymmetry (PMV40 - PMV60 - PMV70)<br />
Reset delay<br />
Trip delay<br />
Reset delay<br />
Set point<br />
asymmetry<br />
Hysteresis<br />
L1 - L2 - L3<br />
On<br />
Asymmetry<br />
11<br />
14<br />
12<br />
Current monitoring of single-phase systems<br />
PMA20<br />
Automatic resetting<br />
Manual resetting<br />
PMA20<br />
2<br />
10<br />
2<br />
10<br />
Us<br />
0.02A<br />
1A<br />
5A<br />
16A<br />
A1 A2 R I B4 B3 B2 B1 C 11 12 14<br />
B2÷B4<br />
9<br />
RESET<br />
11<br />
3<br />
INHIBITION<br />
11<br />
9<br />
RESET<br />
11<br />
3<br />
INHIBITION<br />
11<br />
RESET<br />
INHIBITION<br />
C<br />
L1<br />
L2<br />
L3<br />
L1<br />
L2<br />
L3<br />
7<br />
6<br />
5<br />
I<br />
Set Point<br />
5÷100% f.s.<br />
5-30%<br />
7<br />
6<br />
5<br />
I<br />
Set Point<br />
5÷100% f.s.<br />
Inhibition 0.1-20s<br />
Delay 0.1-20s<br />
t<br />
Inhibition<br />
0.1-20s<br />
Delay<br />
0.1-20s<br />
Manual<br />
Reset<br />
t<br />
PMA21 Automatic resetting Manual resetting<br />
PMA21<br />
2<br />
10<br />
2<br />
10<br />
Us<br />
A1 A2 R I B4 B3 B2 B1 C 11 12 14<br />
B2÷B4<br />
RESET<br />
INHIBITION<br />
0.02A<br />
1A<br />
5A<br />
16A<br />
C<br />
L1<br />
L2<br />
L3<br />
L1<br />
L2<br />
L3<br />
9<br />
9<br />
RESET<br />
RESET<br />
11<br />
11<br />
3<br />
3<br />
INHIBITION<br />
INHIBITION<br />
11<br />
11<br />
7<br />
6<br />
6<br />
5<br />
I<br />
Set Point<br />
Set Point<br />
5÷100% f.s. 5÷100% f.s.<br />
5-30%<br />
7<br />
5<br />
I<br />
Inhibition 0.1-20s<br />
Delay 0.1-20s<br />
t<br />
Inhibition<br />
0.1-20s<br />
Delay<br />
0.1-20s<br />
Manual<br />
Reset<br />
t<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com
W-14 Wiring diagrams<br />
Protection relays<br />
electric<br />
PMA30<br />
Automatic resetting<br />
Manual resetting<br />
Manual pulse resetting<br />
PMA30<br />
A1<br />
A2<br />
A1<br />
A2<br />
A1<br />
A2<br />
W<br />
Us<br />
0.02A<br />
1A<br />
5A<br />
16A<br />
A1 A2 R I B4 B3 B2 B1 C 11 12 14<br />
B2÷B4<br />
ON<br />
A1<br />
RESET<br />
R<br />
A1<br />
INHIBITION<br />
I<br />
ON<br />
A1<br />
RESET<br />
R<br />
A1<br />
INHIBITION<br />
I<br />
ON<br />
A1<br />
RESET<br />
R<br />
A1<br />
INHIBITION<br />
I<br />
Inhibition<br />
Reset<br />
RESET<br />
INHIBITION<br />
C<br />
L1<br />
L2<br />
L3<br />
14<br />
11<br />
12<br />
I<br />
14<br />
11<br />
12<br />
I<br />
14<br />
11<br />
12<br />
I<br />
L1<br />
L2<br />
L3<br />
Set Point<br />
5÷100% f.s.<br />
5-30%<br />
Set Point<br />
5÷100% f.s.<br />
5-30%<br />
Set Point<br />
5÷100% f.s.<br />
5-30%<br />
Inhibition 0.1-20s<br />
Delay 0.1-20s<br />
t<br />
Reset Delay<br />
0.1-20s<br />
Inhibition<br />
0.1-20s<br />
Delay<br />
0.1-20s<br />
Reset Delay<br />
0.1-20s<br />
Manual<br />
Reset<br />
t<br />
Inhibition 0.1-20s<br />
Delay 0.1-20s<br />
Reset Delay<br />
0.1-20s<br />
t<br />
Automatic resetting<br />
Manual resetting<br />
Manual pulse resetting<br />
A1<br />
A2<br />
A1<br />
A2<br />
A1<br />
A2<br />
ON<br />
A1<br />
RESET<br />
R<br />
ON<br />
A1<br />
RESET<br />
R<br />
ON<br />
A1<br />
RESET<br />
R<br />
Inhibition<br />
Reset<br />
A1<br />
INHIBITION<br />
I<br />
A1<br />
INHIBITION<br />
I<br />
A1<br />
INHIBITION<br />
I<br />
14<br />
11<br />
12<br />
I<br />
14<br />
11<br />
12<br />
I<br />
14<br />
11<br />
12<br />
I<br />
Set Point<br />
5÷100% f.s.<br />
5-30%<br />
Set Point<br />
5÷100% f.s.<br />
5-30%<br />
Set Point<br />
5÷100% f.s.<br />
5-30%<br />
Inhibition 0.1-20s<br />
Delay 0.1-20s<br />
Reset Delay<br />
0.1-20s<br />
t<br />
Inhibition 0.1-20s<br />
Delay 0.1-20s<br />
Reset Delay<br />
0.1-20s<br />
t<br />
Inhibition 0.1-20s<br />
Delay 0.1-20s<br />
Reset Delay<br />
0.1-20s<br />
t<br />
Manual Reset<br />
Frequency monitoring<br />
Reset delay<br />
MAX Delay<br />
Reset delay<br />
MIN Delay<br />
Reset delay<br />
PMF20<br />
Set up Hz MAX<br />
Hysteresis<br />
A1<br />
A2<br />
Nominal<br />
frequency<br />
MAX Delay<br />
Reset delay<br />
A1 A2<br />
F. Detect<br />
Hysteresis<br />
Set up Hz MIN<br />
Set up Hz MAX<br />
Hysteresis<br />
14<br />
12 11<br />
A1 - A2<br />
Nominal<br />
frequency<br />
Hz MAX<br />
A1 - A2<br />
Hz MIN<br />
Hz MAX<br />
Phase shift monitoring<br />
ON<br />
14<br />
Relay 11<br />
12<br />
ON<br />
14<br />
Relay 11<br />
12<br />
PMA40 - PMA50 Automatic resetting Manual resetting<br />
16A<br />
PMA40<br />
PMA50<br />
A1 A2 R B4 B3 B2 B1 C 11 12 14<br />
A1<br />
A2<br />
ON<br />
A1<br />
RESET<br />
R<br />
A1<br />
A2<br />
ON<br />
A1<br />
RESET<br />
R<br />
L2<br />
L3<br />
RESET<br />
B1 C<br />
L1<br />
L2<br />
L3<br />
14<br />
11<br />
12<br />
I<br />
14<br />
11<br />
12<br />
I<br />
L1<br />
L2<br />
L3<br />
Set Point<br />
cosϕ<br />
5-30%<br />
Set Point<br />
cosϕ<br />
5-30%<br />
Inhibition 0.1-20s<br />
Delay 0.1-20s<br />
Reset Delay<br />
0.1-20s<br />
t<br />
Inhibition 0.1-20s<br />
Delay 0.1-20s<br />
Reset Delay<br />
0.1-20s<br />
Manual<br />
Reset<br />
t<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com
electric<br />
Wiring diagrams<br />
Liquid level control relays<br />
W-15<br />
Emptying function<br />
LVM20<br />
LVM20<br />
W<br />
24VAC<br />
110-127VAC<br />
220-240VAC<br />
380-415VAC<br />
A1 A2 COM MAX MIN 12 14 11<br />
0VAC<br />
-MAX<br />
-MIN<br />
-COM<br />
Emptying function with 3 electrodes<br />
Emptying function with 2 electrodes<br />
COM<br />
MIN<br />
MAX<br />
COM<br />
MAX<br />
MIN<br />
ON<br />
LVM20<br />
A2<br />
A1<br />
ON<br />
LVM20<br />
A2<br />
A1<br />
RELAY<br />
RELAY<br />
11<br />
14<br />
12<br />
11<br />
14<br />
12<br />
Emptying or filling functions<br />
LVM25<br />
LVM25<br />
Emptying function (DOWN)<br />
Connection with 3 electrodes<br />
COM<br />
MIN<br />
MAX<br />
PROBE SIGNAL<br />
OR STARTING DELAY ❶<br />
PROBE SIGNAL DELAY ❶<br />
Connection with 2 electrodes<br />
COM<br />
MAX<br />
MIN<br />
PROBE SIGNAL OR STARTING DELAY ❶<br />
PROBE SIGNAL DELAY ❶<br />
A1 A2 COM MAX MIN 12 14 11<br />
ON<br />
SUPPLY<br />
SUPPLY<br />
ON<br />
24-48VAC/DC<br />
110-240VAC/DC<br />
RELAY<br />
RELAY<br />
0VAC<br />
LVM30<br />
-MAX<br />
-MIN<br />
-COM<br />
RELAY<br />
❷<br />
24<br />
21<br />
22<br />
14<br />
11<br />
12<br />
❶ Time delay for LVM30 only.<br />
❷ SPDT contact for LVM30 only.<br />
RELAY<br />
24<br />
21<br />
22<br />
14<br />
11<br />
12<br />
LVM30<br />
Filling function (UP)<br />
Connection with 3 electrodes<br />
Connection with 2 electrodes<br />
PROBE SIGNAL<br />
OR STARTING DELAY ❶<br />
PROBE SIGNAL DELAY ❶<br />
PROBE SIGNAL OR STARTING DELAY ❶<br />
220-240VAC<br />
380-415VAC<br />
A1 A2 COM MAX MIN<br />
A3 14 12 11 24 22 21<br />
COM<br />
MIN<br />
MAX<br />
PROBE SIGNAL<br />
OR STARTING DELAY ❶<br />
COM<br />
MAX<br />
PROBE SIGNAL DELAY ❶<br />
24VAC<br />
110-127VAC<br />
0VAC<br />
-MAX<br />
-MIN<br />
-COM<br />
ON<br />
SUPPLY<br />
SUPPLY<br />
ON<br />
RELAY<br />
RELAY<br />
RELAY<br />
❷<br />
24<br />
21<br />
22<br />
14<br />
11<br />
12<br />
❶ Time delay for LVM30 only.<br />
❷ SPDT contact for LVM30 only.<br />
RELAY<br />
24<br />
21<br />
22<br />
14<br />
11<br />
12<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com
W-16 Wiring diagrams<br />
Liquid level control relays<br />
electric<br />
Multiple functions<br />
LVM40<br />
LVM40<br />
Emptying function + alarms<br />
COM<br />
MIN 2<br />
MIN 1<br />
MAX 1<br />
MAX 2<br />
➋ ➊ ➊ ➋ ➊ ➋ ➋<br />
W<br />
ON<br />
A2<br />
A1<br />
24VAC<br />
110-127VAC<br />
220-240VAC<br />
380-415VAC<br />
0VAC<br />
A1 A2 COM MIN2 MIN1 MAX1 MAX2 13 11 22 24 21<br />
-MAX2<br />
-MAX1<br />
-MIN1<br />
-MIN2<br />
-COM<br />
14<br />
13<br />
21 24<br />
22<br />
Filling function + alarms<br />
COM<br />
MIN 2<br />
MIN 1<br />
MAX 1<br />
MAX 2<br />
➊<br />
➋ ➊ ➋ ➋ ➋ ➋ ➋<br />
ON<br />
A2<br />
A1<br />
14<br />
13<br />
24<br />
21<br />
22<br />
Filling function + pump start change<br />
COM<br />
MIN 1<br />
MIN 2<br />
MAX 1<br />
MAX 2<br />
➊ ➋ ➊ ➋ ➊ ➊ ➋ ➊ ➊<br />
ON<br />
A2<br />
A1<br />
14<br />
13<br />
21 24<br />
22<br />
5 sec<br />
Filling function + pump start change<br />
COM<br />
MIN 2<br />
MIN 1<br />
MAX 2<br />
MAX 1<br />
➊ ➋ ➊ ➋ ➊ ➊ ➋ ➊<br />
ON<br />
A2<br />
A1<br />
14<br />
13<br />
24<br />
21<br />
22<br />
5 sec<br />
Filling tank and draining well function + alarm<br />
COM<br />
MIN 1<br />
MAX 1<br />
➊<br />
➋<br />
➊<br />
➋<br />
➊<br />
Tank<br />
COM<br />
MIN 2<br />
MAX 2<br />
Well<br />
ON<br />
A2<br />
A1<br />
14<br />
13<br />
➊ Probe signal and starting delay<br />
➋ Probe signal delay<br />
21 24<br />
22<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com
electric<br />
Wiring diagrams<br />
Liquid level control relays<br />
W-17<br />
Startup priority change monitoring<br />
LVM P05<br />
A1 13<br />
Relay<br />
1<br />
Relay<br />
2<br />
ON<br />
A1<br />
A2<br />
W<br />
A2<br />
14 24<br />
14<br />
13<br />
24<br />
13<br />
LVM P10<br />
2-wire connection<br />
A1<br />
14<br />
Relay 1<br />
24<br />
Relay 2<br />
ON<br />
A2<br />
A1<br />
C-S1<br />
A2<br />
C<br />
S1 S2<br />
C<br />
R1 R2<br />
13<br />
23<br />
C-S2<br />
RELAY 1<br />
RELAY 2<br />
13<br />
14<br />
23<br />
24<br />
DELAY<br />
S1 = Primary<br />
S2 = Secondary / Standby<br />
3-wire connection<br />
A1<br />
14<br />
24<br />
ON<br />
A2<br />
A1<br />
Relay 1<br />
Relay 2<br />
C-S1<br />
A2<br />
C S1 S2 C R1 R2 13 23<br />
C-R1<br />
C-S2<br />
C-R2<br />
RELAY 1<br />
13<br />
14<br />
RELAY 2<br />
23<br />
24<br />
DELAY<br />
S1 = Primary<br />
S2 = Secondary / Standby<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com
W-18 Wiring diagrams<br />
Digital metering instruments<br />
electric<br />
W<br />
DMK 80 - DMK 80R1<br />
DMK 00 - DMK 00R1<br />
L<br />
L/N<br />
L<br />
L/N<br />
600VAC<br />
METER<br />
DMK 81 - DMK 81R1<br />
DMK 01 - DMK 01R1<br />
L<br />
L/N<br />
S1<br />
5<strong>AA</strong>C<br />
S2<br />
METER<br />
DMK 82<br />
DMK 02<br />
L<br />
L/N<br />
L<br />
L/N<br />
600VAC<br />
S1<br />
METER<br />
5<strong>AA</strong>C<br />
S2<br />
DMK 83 - DMK 83R1<br />
DMK 03 - DMK 03R1<br />
L<br />
L/N<br />
L<br />
L/N<br />
600VAC 45/65Hz<br />
METER<br />
DMK 84 - DMK 84R1<br />
DMK 04 - DMK 04R1<br />
L1<br />
L2<br />
L3<br />
N<br />
L<br />
L/N<br />
600VAC<br />
S1<br />
METER<br />
5<strong>AA</strong>C<br />
S2<br />
A1 A2 14 12 11<br />
A1 A2 14 12 11<br />
A1<br />
A2<br />
A1 A2 14 12 11<br />
A1<br />
A2<br />
14 12 11<br />
110...127VAC<br />
Only for DMK... R1<br />
110...127VAC<br />
Only for DMK... R1<br />
110...127VAC<br />
110...127VAC<br />
Only for DMK... R1<br />
110...127VAC<br />
Only for DMK... R1<br />
DMK 70 - DMK 70R1<br />
DMK 10 - DMK 10R1<br />
L1<br />
L2<br />
L3<br />
N<br />
DMK 71 - DMK 71R1<br />
DMK 11 - DMK 11R1<br />
L1<br />
L2<br />
L3<br />
N<br />
DMK 75 - DMK 75R1<br />
DMK 15 - DMK 15R1<br />
DMK 16<br />
L1<br />
L2<br />
L3<br />
N<br />
L1<br />
L2<br />
L3<br />
N<br />
I1 I2 I3 COM<br />
L1 L2 L3 N<br />
I1 I2 I3 COM<br />
600VAC<br />
METER<br />
METER<br />
5<strong>AA</strong>C<br />
600VAC<br />
METER<br />
5<strong>AA</strong>C<br />
A1<br />
A2<br />
14 12 11<br />
A1<br />
A2<br />
14 12 11<br />
A1<br />
A2<br />
14 13<br />
110...127VAC<br />
Only for DMK... R1<br />
110...127VAC<br />
Only for DMK... R1<br />
110...127VAC<br />
Only for DMK... R1<br />
DMK20 - DMK21 - DMK22 - DMK25 - DMK26<br />
Single phase<br />
Two phase<br />
Three phase with or without neutral<br />
L<br />
N<br />
CT1<br />
L<br />
O<br />
A<br />
D<br />
L1<br />
L2<br />
N<br />
CT1<br />
CT2<br />
L<br />
O<br />
A<br />
D<br />
L1<br />
L2<br />
L3<br />
N<br />
CT1<br />
CT2<br />
CT3<br />
L<br />
O<br />
A<br />
D<br />
110...127VAC❶<br />
110...127VAC❶<br />
110...127VAC❶<br />
L<br />
N<br />
L1 L2 L3 N I1 I2 I3<br />
C<br />
L<br />
N<br />
L1 L2 L3 N I1 I2 I3 C<br />
L<br />
N<br />
L1 L2 L3<br />
N<br />
I1 I2 I3 C<br />
AUX SUPPLY<br />
VOLTAGE<br />
CURRENT<br />
AUX SUPPLY<br />
VOLTAGE<br />
CURRENT<br />
AUX SUPPLY<br />
VOLTAGE<br />
CURRENT<br />
Three phase without neutral with ARON connection<br />
L1<br />
L2<br />
L3<br />
CT1<br />
CT2<br />
L<br />
O<br />
A<br />
D<br />
L1<br />
L2<br />
L3<br />
CT1<br />
CT3<br />
L<br />
O<br />
A<br />
D<br />
110...127VAC❶<br />
110...127VAC❶<br />
L<br />
N<br />
L1 L2 L3 N I1 I2 I3 C<br />
L<br />
N<br />
L1 L2<br />
L3<br />
N<br />
I1<br />
I2<br />
I3 C<br />
AUX SUPPLY<br />
VOLTAGE<br />
CURRENT<br />
AUX SUPPLY<br />
VOLTAGE<br />
CURRENT<br />
❶ 12-24VDC battery power supply for DMK25 or DMK26 (L = “-” and N = “+”).<br />
DMK50 - DMK51 - DMK52<br />
Single phase<br />
Two phase<br />
Three phase with or without neutral<br />
L<br />
N<br />
CT1<br />
L<br />
O<br />
A<br />
D<br />
L1<br />
L2<br />
N<br />
CT1<br />
CT2<br />
L<br />
O<br />
A<br />
D<br />
L1<br />
L2<br />
L3<br />
N<br />
CT1<br />
CT2<br />
CT3<br />
L<br />
O<br />
A<br />
D<br />
110...1274VAC<br />
110...1274VAC<br />
110...1274VAC<br />
10<br />
12<br />
30 32 34 36 14 15 16<br />
17<br />
18<br />
10<br />
12<br />
30 32 34 36 14 15 16<br />
17<br />
18<br />
10<br />
12<br />
30 32 34 36 14 15 16<br />
17<br />
18<br />
L<br />
N<br />
L1 L2 L3 N<br />
C C I1<br />
I2<br />
I3<br />
L<br />
N<br />
L1 L2 L3 N<br />
C C I1 I2 I3<br />
L<br />
N<br />
L1 L2 L3 N<br />
C C I1<br />
I2<br />
I3<br />
AUX SUPPLY<br />
VOLTAGE<br />
CURRENT<br />
AUX SUPPLY<br />
VOLTAGE<br />
CURRENT<br />
AUX SUPPLY<br />
VOLTAGE<br />
CURRENT<br />
Three phase without neutral with ARON connection<br />
L1<br />
L2<br />
L3<br />
CT1<br />
CT2<br />
L<br />
O<br />
A<br />
D<br />
L1<br />
L2<br />
L3<br />
CT1<br />
CT3<br />
L<br />
O<br />
A<br />
D<br />
110...1274VAC<br />
110...1274VAC<br />
10 12<br />
30<br />
34 32 36 15 14 16<br />
17 18<br />
10<br />
12<br />
30 32 34 36 14 15 16<br />
17<br />
18<br />
L<br />
N<br />
L1 L2 L3 N<br />
C C I1<br />
I2<br />
I3<br />
L<br />
N<br />
L1 L2 L3 N<br />
C C I1<br />
I2<br />
I3<br />
AUX SUPPLY<br />
VOLTAGE<br />
CURRENT<br />
AUX SUPPLY<br />
VOLTAGE<br />
CURRENT<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com
electric<br />
Wiring diagrams<br />
Digital metering instruments<br />
W-19<br />
DMK30 - DMK31 - DMK32 - DMK40 - DMK60 - DMK61 - DMK62<br />
Single phase<br />
Two phase<br />
Three phase with or without neutral<br />
CT1<br />
L<br />
O<br />
A<br />
D<br />
CT1<br />
CT2<br />
L<br />
O<br />
A<br />
D<br />
CT1<br />
CT2<br />
CT3<br />
L<br />
O<br />
A<br />
D<br />
W<br />
100...240VAC<br />
100...240VAC<br />
100...240VAC<br />
GND<br />
L1 L2 L3 N S1S2 S1 S2 S1S2<br />
GND<br />
L1 L2 L3 N S1S2 S1S2 S1S2<br />
GND<br />
L1 L2 L3 N S1S2 S1S2 S1S2<br />
AUX SUPPLY<br />
VOLTAGE<br />
INPUT<br />
CURRENT<br />
INPUT<br />
AUX SUPPLY<br />
VOLTAGE<br />
INPUT<br />
CURRENT<br />
INPUT<br />
AUX SUPPLY<br />
VOLTAGE<br />
INPUT<br />
CURRENT<br />
INPUT<br />
Three phase without neutral with ARON connection<br />
CT1<br />
CT2<br />
L<br />
O<br />
A<br />
D<br />
CT1<br />
CT3<br />
L<br />
O<br />
A<br />
D<br />
100...240VAC<br />
100...240VAC<br />
GND<br />
L1 L2 L3 N S1S2 S1S2 S1S2<br />
GND<br />
L1 L2 L3 N S1 S2 S1 S2 S1 S2<br />
AUX SUPPLY VOLTAGE CURRENT<br />
AUX SUPPLY VOLTAGE CURRENT<br />
Automatic power factor controllers<br />
DCRK with BFK contactors<br />
DCRJ with BFK contactors<br />
MAINS<br />
L1 L2 L3<br />
DCRK12<br />
CURRENT<br />
/5A<br />
VOLTAGE<br />
0V<br />
380-415V<br />
1 2 3 4 5 6 7 8 9 10 11 12<br />
MAINS<br />
L1 L2 L3<br />
DCRJ12<br />
CURRENT<br />
/5A<br />
AUX<br />
SUPPLY<br />
0V<br />
110-127VAC<br />
220-240VAC<br />
INPUT<br />
VOLTAGE<br />
100-690VAC<br />
1 2 3 4 5 6 7 8 9 10 11 12<br />
RS485<br />
TEMP.<br />
SENSOR<br />
TR<br />
A<br />
B<br />
SG<br />
18<br />
19<br />
NTC01<br />
S1 S2 15 16 C 1 2 3 4 5 6 7 8 9 10 11 12 13 14<br />
S1 S2 15 16 17 L1 L2 L3 C 1 2 3 4 5 6 7 8 9 10 11 12 13 14<br />
CT1<br />
CT1<br />
FU16<br />
FU17<br />
QS1<br />
FU13 FU14 FU15<br />
FU1<br />
FU2<br />
FU12<br />
QS1<br />
FU13<br />
FU16<br />
FU14<br />
FU15<br />
FU1<br />
FU2<br />
FU12<br />
KM1<br />
KM2<br />
KM12<br />
KM1<br />
KM2<br />
KM12<br />
LOAD<br />
LOAD<br />
K1<br />
K2<br />
K12<br />
K1<br />
K2<br />
K12<br />
IMPORTANT!<br />
a. For three-phase connection, the voltage input must be connected between two phases; the line current<br />
transformer must be connected on the remaining phase.<br />
b. The polarity of the current input is irrelevant.<br />
c. When the auxiliary source is available, the line to be controlled (maximum 240VAC) can supply the<br />
controller.<br />
CAUTION! Always cut off the power supply when operating on the terminals.<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com
W-20 Wiring diagrams<br />
Automatic transfer switch controllers<br />
electric<br />
ATL<br />
W<br />
LINE 1<br />
L1 L2 L3 N<br />
LINE 2<br />
L1 L2 L3 N<br />
QF1<br />
QF2<br />
8.1<br />
8.2<br />
8.3<br />
8.4<br />
9.1<br />
9.2<br />
9.3<br />
5.1 5.2 5.3 4.1 4.2 4.3 4.4 4.5 4.6 4.7 4.8<br />
+ _ _<br />
DIGITAL INPUTS<br />
DC<br />
SUPPLY<br />
RS232<br />
RS485<br />
SG 6.1<br />
B 6.2<br />
A 6.3<br />
TR 6.4<br />
9.4<br />
Q1<br />
Q2<br />
7.1<br />
7.2<br />
1.1 1.2 1.3<br />
2.1 2.2 2.3 3.1 3.2 3.3 3.5 3.4 3.6 3.7 3.8<br />
L1 L2 L3 N<br />
LOAD<br />
Programmable logic relays<br />
LRD12R D024<br />
LRD12T D024<br />
LRD12R A024<br />
LRD10R A240<br />
24VDC DIGITAL<br />
24VDC 24VDC 0...10VDC ANALOG<br />
24VDC<br />
24VDC<br />
24VDC DIGITAL<br />
0...10VDC ANALOG<br />
24VAC<br />
24VAC<br />
100...240VAC<br />
100...240VAC<br />
+ – I1 I2 I3 I4 I5 I6 A1 A2<br />
DIGITAL INPUT DIGITAL/ANALOG<br />
INPUT<br />
+ –<br />
I1 I2 I3 I4 I5 I6<br />
DIGITAL INPUT<br />
A1 A2<br />
DIGITAL/ANALOG<br />
INPUT<br />
L N<br />
I1 I2 I3 I4 I5 I6<br />
DIGITAL INPUT<br />
L N<br />
I1 I2 I3 I4 I5 I6<br />
DIGITAL INPUT<br />
RELAY OUTPUT<br />
RELAY OUTPUT<br />
RELAY OUTPUT<br />
Q1 Q2 Q3 Q4<br />
TRANSISTOR OUTPUT<br />
Q2 Q3 Q1 Q4<br />
+ – + – + – + –<br />
Q1 Q2 Q3 Q4<br />
Q1 Q2 Q3 Q4<br />
24VDC<br />
LRD20R D024<br />
LRD20T D024<br />
24VDC<br />
24VDC<br />
24VDC DIGITAL<br />
0...10VDC ANALOG<br />
24VDC<br />
24VDC<br />
24VDC DIGITAL<br />
0...10VDC ANALOG<br />
+ – I1 I2 I3 I4 I5 I6 I7 I8 A1 A2 A3 A4<br />
DIGITAL INPUT<br />
DIGITAL/ANALOG<br />
INPUT<br />
RELAY OUTPUT<br />
Q1 Q2 Q3 Q4 Q5 Q6 Q7 Q8<br />
+ – I1 I2 I3 I4 I5 I6 I7 I8 A1 A2 A3 A4<br />
DIGITAL INPUT<br />
DIGITAL/ANALOG<br />
INPUT<br />
TRANSISTOR OUTPUT<br />
Q1 Q2 Q3 Q4 Q5 Q6 Q7 Q8<br />
+ – + – + – + – + – + – + – + –<br />
24VDC<br />
LRD20R A024<br />
LRD20R A240<br />
24VAC<br />
24VAC<br />
100...240VAC<br />
100...240VAC<br />
L<br />
N<br />
I1 I2 I3 I4 I5 I6 I7 I8 I9 IA IB IC<br />
L<br />
N<br />
I1 I2 I3 I4 I5 I6 I7 I8 I9 IA IB IC<br />
DIGITAL INPUT<br />
DIGITAL INPUT<br />
RELAY OUTPUT<br />
RELAY OUTPUT<br />
Q1 Q2 Q3 Q4 Q5 Q6 Q7 Q8<br />
Q1 Q2 Q3 Q4 Q5 Q6 Q7 Q8<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com
electric<br />
Wiring diagrams<br />
Programmable logic relays<br />
W-21<br />
Expansion modules<br />
LRE08R D024<br />
LRE08T D024<br />
LRE8R A024<br />
LRE8R A240<br />
24VDC<br />
24VDC<br />
24VDC<br />
24VDC<br />
24VAC<br />
24VAC<br />
100...240VAC 100...240VAC<br />
+ –<br />
X1<br />
X2 X3<br />
X4<br />
DIGITAL INPUT<br />
RELAY OUTPUT<br />
+ –<br />
X1<br />
X2 X3<br />
X4<br />
DIGITAL INPUT<br />
L N<br />
X1 X2 X3 X4<br />
DIGITAL INPUT<br />
RELAY OUTPUT<br />
L N<br />
X1 X2 X3 X4<br />
DIGITAL INPUT<br />
RELAY OUTPUT<br />
W<br />
Y1 Y2 Y3 Y4<br />
TRANSISTOR OUTPUT<br />
Y1 Y2 Y3 Y4<br />
+ – + – + – + –<br />
Y1 Y2 Y3 Y4<br />
Y1 Y2 Y3 Y4<br />
24VDC<br />
Power supply module<br />
LRX 1V3 D024<br />
Communication module<br />
LRE P00<br />
100...240VAC<br />
VOut<br />
24VDC<br />
L<br />
N<br />
+ –<br />
OUTPUT<br />
+ + – –<br />
OUTPUT<br />
A B S<br />
24VDC - 1.3A<br />
RS485<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com
Technical charact<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com
TC<br />
Technical characteristics<br />
®<br />
electric<br />
teristics<br />
®<br />
electric<br />
100% electricity<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com
TC-2<br />
Technical characteristics<br />
Manual motor starters and protectors<br />
®<br />
electric<br />
TC<br />
Operational<br />
characteristics<br />
TYPE<br />
SM1B SM2A SM3A LMS25<br />
CONTACT AND RELEASE CHARACTERISTICS<br />
Rated insulation voltage Ui V 690<br />
Rated frequency Hz 50/60<br />
Rated impulse voltage Uimp kV 6<br />
Maximum rated current A 32 50 100 25<br />
Number of adjustment ranges 15 4 4 13<br />
Power dissipation per phase W 2.2-9.7 7.1-20 10-38 2-15<br />
Magnetic tripping 12 In 13 In 13 In 12In<br />
Mechanical life cycles 100,000 25,000 25,000 100,000<br />
<strong>Electric</strong>al life (Ie max AC3) cycles 100,000 50,000 50,000 100,000<br />
Maximum tightening Nm 2.3 4.5 6 2<br />
torque for terminals lbft 1.7 3.3 4.4 1.5<br />
Tool PH2 PZ2 Allen 4mm PZ2<br />
Minimum-maximum conductor section<br />
connectable 1 or 2 wires<br />
AWG n° 16-10 18-3 10-1/0 14-8<br />
Flexible without lug mm 2 1-6 0.75-25 10-50 0.75-4<br />
AMBIENT CONDITIONS<br />
Temperature Operating °F -4 to +160 -4 to +160 -4 to +160 -15 to -120❶<br />
(-20 to +70°C) (-20 to +70°C) (-20 to +70°C) (-25 to +50°C)<br />
Storage °F -60 to +175 -60 to +175 -60 to +175 -60 to +160<br />
(-50 to +80°C) (-50 to +80°C) (-50 to +80°C) (-50 to +70°C)<br />
Compensation °F -4 to +120 -4 to +120 -4 to +120 -4 to +120<br />
(-20 to +50°C) (-20 to +50°C) (-20 to +50°C) (-20 to +50°C)❶<br />
Maximum altitude ft 9800 (3000m)<br />
Mounting position<br />
any<br />
Mounting 35mm DIN rail Screw fixing Screw fixing Screw fixing<br />
(IEC/EN 60715) or 35mm or DIN rail 35mm or 35mm<br />
DIN rail (IEC/EN 60715) DIN rail<br />
(IEC/EN 60715) or 75mm (IEC/EN 60715)<br />
(IEC/EN 60715)<br />
N.B. PH = Phillips; PZ = Pozidrive; Allen is metric type.<br />
❶ Value in free air temperature: -4 to -105°F(-20 to +40°C) in enclosure.<br />
Thermal tripping<br />
curve<br />
100<br />
60<br />
40<br />
10<br />
5<br />
2<br />
1<br />
[min]<br />
Opening time<br />
[s]<br />
10,000<br />
5,000<br />
2,000<br />
1,000<br />
500<br />
200<br />
100<br />
50<br />
A<br />
Tripping times at cold state are an<br />
indication only. The tripping time at<br />
hot state is obtained by multiplying the<br />
value obtained from the characteristic<br />
curve by 0.75.<br />
A = Balanced 3-phase operation<br />
B = 2-phase operation (phase failure)<br />
Ie = Rated current<br />
20<br />
10<br />
5<br />
2<br />
1<br />
0.5<br />
0.2<br />
0.1<br />
0.05<br />
B<br />
0.02<br />
0.01<br />
0.005<br />
0.002<br />
0.001<br />
0.6<br />
1 2 3 4 6 8 10 20 30 40 60 80<br />
0.8<br />
x I [A]<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com
®<br />
electric<br />
Technical characteristics<br />
IEC style contactors<br />
TC-3<br />
IEC breaking capacity<br />
Type Thermal trip Rated short-circuit breaking capacity [kA] Protection fuses when I > Icu<br />
adjustment range<br />
(gL or gG fuses) ❶<br />
230V 400V 500V 690V 230V 400V 500V 690V<br />
[A] Icu Ics Icu Ics Icu Ics Icu Ics [A] [A] [A] [A]<br />
SM1B 00 0.1-0.16 100 100 100 100 100 100 100 100 ▲ ▲ ▲ ▲<br />
SM1B 04 0.16-0.25 100 100 100 100 100 100 100 100 ▲ ▲ ▲ ▲<br />
SM1B 08 0.25-0.4 100 100 100 100 100 100 100 100 ▲ ▲ ▲ ▲<br />
SM1B 12 0.4-0.63 100 100 100 100 100 100 100 100 ▲ ▲ ▲ ▲<br />
SM1B 16 0.63-1 100 100 100 100 100 100 100 100 ▲ ▲ ▲ ▲<br />
SM1B 20 1-1.6 100 100 100 100 100 100 100 100 ▲ ▲ ▲ ▲<br />
SM1B 24 1.6-2.5 100 100 100 100 100 100 8 8 ▲ ▲ ▲ 35<br />
SM1B 28 2.5-4 100 100 100 100 100 100 8 8 ▲ ▲ ▲ 35<br />
SM1B 32 4-6.5 100 100 100 100 100 100 8 8 ▲ ▲ ▲ 40<br />
SM1B 36 6.3-10 100 100 100 100 42 21 8 8 ▲ ▲ 63 50<br />
SM1B 40 9-14 100 100 25 12.5 10 5 2 2 ▲ 80 63 50<br />
SM1B 44 13-18 100 100 25 12.5 4 2 2 2 ▲ 100 80 63<br />
SM1B 48 17-23 100 100 25 12.5 4 2 2 2 ▲ 100 80 63<br />
SM1B 52 20-25 100 100 25 12.5 4 2 2 2 ▲ 100 80 63<br />
SM1B 56 24-32 100 100 25 12.5 4 2 2 2 ▲ 100 80 63<br />
TC<br />
SM2A 64 22-32 100 100 50 25 10 5 4 2 ▲ 125 100 63<br />
SM2A 68 28-40 100 100 50 25 10 5 4 2 ▲ 160 100 63<br />
SM2A 72 36-45 100 100 50 25 10 5 4 2 ▲ 160 100 63<br />
SM2A 76 40-50 100 100 50 25 10 5 4 2 ▲ 160 100 80<br />
SM3A 84 45-63 100 100 50 25 12 6 6 3 ▲ 160 100 80<br />
SM3A 88 57-75 100 100 50 25 8 4 5 3 ▲ 160 125 100<br />
SM3A 92 70-90 100 100 50 25 8 4 5 3 ▲ 160 125 125<br />
SM3A 96 80-100 100 100 50 25 8 4 5 3 ▲ 160 125 125<br />
LMS25 016T 0.1-0.16 100 100 100 100 100 100 100 100 ▲ ▲ ▲ ▲<br />
LMS25 025T 0.16-0.25 100 100 100 100 100 100 100 100 ▲ ▲ ▲ ▲<br />
LMS25 04T 0.25-0.4 100 100 100 100 100 100 100 100 ▲ ▲ ▲ ▲<br />
LMS25 063T 0.4-0.63 100 100 100 100 100 100 100 100 ▲ ▲ ▲ ▲<br />
LMS25 1T 0.63-1 100 100 100 100 100 100 100 100 ▲ ▲ ▲ ▲<br />
LMS25 1V6T 1-1.6 100 100 100 100 100 100 100 100 ▲ ▲ ▲ ▲<br />
LMS25 2V5T 1.6-2.5 100 100 100 100 3 3 2.5 2.5 ▲ ▲ 25 20<br />
LMS25 4T 2.5-4 100 100 100 100 3 3 2.5 1.9 ▲ ▲ 35 25<br />
LMS25 6V3T 4-6.3 100 100 100 100 3 2.2 2.5 1.9 ▲ ▲ 50 35<br />
LMS25 10T 6.3-10 100 100 6 3 3 2.2 2.5 1.9 ▲ 80 50 35<br />
LMS25 16T 10-16 6 6 4 2 2.5 1.9 2 1.5 80 80 63 35<br />
LMS25 20T 16-20 6 4.5 4 2 2.5 1.9 2 1.5 80 80 63 50<br />
LMS25 25T 20-25 6 4.5 4 2 2.5 1.9 2 1.5 80 80 63 50<br />
❶ Fuses are used only in those cases when the value of short-circuit current at the starter installation point exceeds the breaking capacity of the starter.<br />
▲ Fuses not required.<br />
Rating data for control-circuit contacts per UL508<br />
UL designation Thermal Maximum Amperes (AC at 60Hz) Maximum VA<br />
continuous 120VAC 240VAC 480VAC 600VAC<br />
test current<br />
Make Break Make Break Make Break Make Break Make Break<br />
A600 10 60 6 30 3 15 1.5 12 1.2 7200 720<br />
C300 2.5 15 1.5 7.5 0.75 –– –– –– –– 1800 180<br />
C300 2.5 15 1.5 7.5 0.75 3.75 0.375 3 0.3 1800 180<br />
Maximum Amperes (DC) Make or Break<br />
Maximum VA<br />
Make or Break<br />
125VDC 250VDC 301-600DC 300V or less<br />
Q300 2.5 0.55 0.27 –– 69<br />
Q600 2.5 0.55 0.27 0.1 69<br />
R300 1 0.22 0.11 –– 28<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com
TC-4<br />
Technical characteristics<br />
IEC style contactors<br />
®<br />
electric<br />
TC<br />
Mounting position<br />
of contactors<br />
ON VERTICAL PLANE<br />
The performances given in this catalogue have been<br />
established with contactors mounted on a vertical plane with<br />
line terminals facing upwards and load terminals facing<br />
downwards.<br />
All contactors can be mounted with a ± 30° inclination to the<br />
vertical axis of the contactor without any derating.<br />
For contactors up to BF110, this inclination can reach ± 90°,<br />
that is with the terminals are facing towards left and right.<br />
For BG mini-contactors:<br />
– Position A (A1-A2 coil terminals facing downwards or<br />
upwards) is not recommended.<br />
– Position with A1-A2 coil terminals facing upwards is not<br />
recommended for types with NC contacts.<br />
±30°<br />
±30°<br />
A2<br />
Pos. A<br />
A1<br />
ON VERTICAL PLANE WITH 30° INCLINATION<br />
All contactors can be mounted on a plane which varies in<br />
respect to the vertical up to ± 30° angle.<br />
On the average, a 5% increase of the minimum pick-up<br />
voltage in -30° position can be noted.<br />
This inclination is greater than the one prescribed by main<br />
naval registers.<br />
ON HORIZONTAL PLANE (FOR BF SERIES CONTACTORS)<br />
Considerable performance variations can be noted.<br />
It is necessary to check the two possible mounting positions:<br />
– when the contactor is energised, the movable equipment<br />
moves upwards.<br />
– when the contactor is energised, the movable equipment<br />
moves downwards.<br />
In the first case, it is difficult to close the contactor while in the<br />
second, to open it.<br />
The variables which could influence the contactor performance,<br />
in addition to the two mounting positions, are:<br />
– type of contactor<br />
– type of control<br />
– contact configuration<br />
– number and type of add-on blocks<br />
– permissible tolerance of auxiliary voltage variation<br />
– ambient temperature.<br />
NOTE: Position B is not recommendable.<br />
Sales & Technical Support can provide further information<br />
concerning operational performances of contactors mounted<br />
on a horizontal plane.<br />
DYNAMIC TYPE TESTS<br />
Our contactors sustained dynamic testing, with contactor mounting position rotated ± 22.5° in respect to the three<br />
orthogonal axes.<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com
®<br />
electric<br />
Technical characteristics<br />
IEC style contactors<br />
TC-5<br />
Utilization<br />
category AC3<br />
POLE CHARACTERISTICS<br />
Squirrel-cage induction motors; breaking at rated motor current.<br />
MAXIMUM OPERATIONAL POWER at ambient temperature ≤130°F (55°C).<br />
Contactor Operational Operational power<br />
type❶ current<br />
(Ue ≤440V) 220/230V 380/400V 415V 440V 500V 660/690V 1000V<br />
[A] [kW] [kW] [kW] [kW] [kW] [kW] [kW]<br />
BG06 6 1.5 2.2 2.4 2.5 3 3 --<br />
BG09 9 2.2 4.0 4.3 4.5 5 5 --<br />
BG12 12 3.2 5.7 6.2 5.5 5 5 --<br />
BF09A-BF9C 9 2.2 4.2 4.5 4.8 5.5 7.5 --<br />
BF12A-BF12C 12 3.2 5.7 6.2 6.2 7.5 10 --<br />
BF16C 16 4.3 7.7 8.5 8.5 10 10 --<br />
BF18A 18 4 7.5 9 9 10 10 --<br />
BF20A-BF20C 20 5.5 9.7 10.6 10.6 13 15 --<br />
BF25A-BF25C 25 7.0 12.5 13.4 13.4 15 18 --<br />
BF26A 26 7.3 13 14 14 15.6 18.5 --<br />
BF32A-BF32C 32 8.8 16 17 17 20 22 --<br />
BF38A 38 11 18.5 18.5 18.5 20 22 --<br />
BF40C 40 11 18.5 18.5 18.5 20 22 --<br />
BF50 50 14.3 25 27.2 27.2 33.2 43.5 25<br />
BF65 65 18.5 33 36 36 45.3 59.7 30<br />
BF80 80 23 41 46 46 56 74 37<br />
BF95 95 27.6 50 55 55 56 74 45<br />
BF110 110 33 61 66 70 59 80 45<br />
B115 110 33 61 66 70 80 100 63<br />
B145 150 46 80 88 93 100 120 75<br />
B180 185 57 100 108 115 123 144 103<br />
B250 265 83 140 155 164 176 212 156<br />
B310 320 100 170 188 200 213 256 180<br />
B400 420 130 225 247 263 271 352 208<br />
B500 520 156 290 306 328 367 416 312<br />
B630 630 198 335 368 368 368 440 368<br />
❶ Contact Sales& Technical Supportfor contactor types not mentioned in the table.<br />
TC<br />
<strong>Electric</strong>al life<br />
<strong>Electric</strong>al life of definite-purpose contactors<br />
10<br />
DPBG12<br />
DPBF09A<br />
DPBF12A<br />
MILLION CYCLES<br />
DPBF18A<br />
DPBF26A<br />
DPBF32A<br />
1<br />
0.5<br />
0.1<br />
1 10 14 20 25 30 40 50 [A]<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com
TC-6<br />
Technical characteristics<br />
IEC style contactors<br />
®<br />
electric<br />
<strong>Electric</strong>al life<br />
AC3 ≤440V<br />
<strong>Electric</strong>al life of contactors with AC control<br />
TC<br />
10<br />
BF09A<br />
BF12A<br />
BF18A<br />
BF25A<br />
BF26A<br />
BF32A<br />
BF38A<br />
BF50<br />
BF65<br />
BF80<br />
BF95<br />
BF110<br />
B115<br />
B145<br />
B180<br />
B250<br />
B310<br />
B400<br />
B500<br />
B630<br />
5<br />
MILLION CYCLES<br />
3<br />
2<br />
1<br />
0.5<br />
0.3<br />
0.2<br />
0.1<br />
10<br />
BF9C<br />
BF12C<br />
BF16C<br />
BF20C<br />
BF25C<br />
BF32C<br />
BF40C<br />
BF50C<br />
BF65C<br />
BF80C<br />
BF95C<br />
B115<br />
B145<br />
B180<br />
B250<br />
B310<br />
B400<br />
B500<br />
B630<br />
5<br />
MILLION CYCLES<br />
3<br />
2<br />
1<br />
0.5<br />
0.3<br />
0.2<br />
BG06 D<br />
BG09 D<br />
BG12 D<br />
0.1<br />
2<br />
3<br />
5<br />
6<br />
10<br />
25<br />
30<br />
100<br />
300<br />
12<br />
16<br />
500<br />
600<br />
1000<br />
20<br />
40<br />
50<br />
200<br />
400<br />
[A]<br />
9<br />
32<br />
65<br />
80<br />
95<br />
110<br />
150<br />
185<br />
250<br />
310<br />
420<br />
520<br />
630<br />
2<br />
3<br />
5<br />
6<br />
10<br />
20<br />
25<br />
30<br />
50<br />
6<br />
100<br />
300<br />
500<br />
600<br />
1000<br />
12<br />
40<br />
50<br />
BG06<br />
BG09<br />
BG12<br />
200<br />
400<br />
[A]<br />
6<br />
9<br />
26<br />
32<br />
65<br />
80<br />
95<br />
110<br />
150<br />
185<br />
50<br />
250<br />
310<br />
420<br />
520<br />
630<br />
18<br />
<strong>Electric</strong>al life of contactors with DC control<br />
BF110C<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com
®<br />
electric<br />
Technical characteristics<br />
IEC style contactors<br />
TC-7<br />
Utilisation<br />
categories DC1,<br />
DC3 and DC5<br />
Pole characteristics<br />
CHOICE CRITERIA<br />
The elements to be considered for the contactor choice are:<br />
-- Rated operational current Ie<br />
-- Rated operational voltage Ue<br />
-- Utilization category and L/R time constant<br />
-- Eventual verification of electrical life.<br />
OPERATING CONDITIONS<br />
Indicated current is valid for:<br />
-- Ambient temperature ≤ 130°F (55°C)<br />
-- Operating cycles: up to 120 cy/h with 60%<br />
on-load factor<br />
up to 250 cy/h with 30%<br />
on-load factor<br />
POLES IN SERIES<br />
It is important to use contactors with the indicated number of<br />
poles in series depending on operating voltage.<br />
The poles in series can be connected to one single polarity or<br />
divided between the two polarities of the circuit indifferently.<br />
NOTE. For voltages lower than 30V, the diagrams, given in<br />
figures 3 and 4, are not recommendable since voltage drops<br />
can take place. In these cases, it is better to use poles in<br />
parallel observing the notes given in the following section.<br />
TC<br />
Examples of poles in series:<br />
1 POLE 2 POLES 3 POLES 4 POLES<br />
Fig. 1 Fig. 2 Fig. 3 Fig. 4<br />
POLES IN PARALLEL<br />
It is possible to increase the electrical life by placing poles in<br />
series when using voltages which require 1 or 2 poles in<br />
parallel.<br />
Poles in parallel do not increase the maximum operational<br />
current given in the following pages; that is, if one pole has a<br />
maximum operational current in DC5 of 8A, two poles in<br />
parallel, it will always be 8A.<br />
With poles in parallel, it is possible to increase the rated<br />
contact capacity (Ith) only if the contactor opens and closes in<br />
no-load conditions or when used as resistance shunts.<br />
In this case, the contact capacity can be increased.<br />
The value can be obtained by multiplying the rated current of<br />
one pole by the factor K given below; e.g.: if one pole carries<br />
10A, three poles in parallel can carry 10 x 2.2 = 22A.<br />
Therefore, the operating current is the one indicated in the<br />
tables, multiplied by the K coefficient given below which take<br />
into consideration the unequal current division on the various<br />
poles.<br />
2 POLES in parallel K = 1.6<br />
3 POLES in parallel K = 2.2<br />
4 POLES in parallel K = 2.8<br />
Examples of poles in parallel:<br />
1 POLE in series and 1 POLE in series and<br />
CONFIGURAZIONI POLI CONFIGURAZIONI CORRENTE CONFIGURAZIONI POLI D'IMPIEGO POLI CORRENTE CORRENTE IN POLI D.C. D'IMPIEGO CORRENTE D'IMPIEGO IN D'IMPIEGO D.C. IN D.C. IN D.C.<br />
1 POLE in series and<br />
Disegno N? BM344 Disegno Disegno N? BM344 Disegno N? BM344 N? BM344<br />
2 POLE in series and<br />
2 POLES in parallel 3 POLES in parallel 4 POLES in parallel 2 POLES in parallel<br />
Fig. 5 Fig. 6 Fig. 7 Fig. 8<br />
MAXIMUM OPERATIONAL CURRENT<br />
See tables on pages TC-8, TC-9 and TC-10.<br />
OTHER CONDITIONS<br />
For different operating conditions or voltage not included<br />
CONFIGURAZIONI POLI CORRENTE<br />
CONFIGURAZIONI D'IMPIEGO<br />
POLI POLI CORRENTE<br />
IN<br />
POLI<br />
D.C.<br />
CORRENTE D'IMPIEGO D'IMPIEGO IN D.C. IN D.C. IN D.C.<br />
among those indicated in the tables, on pages<br />
Disegno<br />
TC-8<br />
N? BM344 Disegno Disegno Disegno N? BM344 N? N? BM344 BM344<br />
to TC-10,<br />
contact Sales & Technical Support.<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com
TC-8<br />
Technical characteristics<br />
IEC style contactors<br />
®<br />
electric<br />
DC utilization<br />
category<br />
POLE CHARACTERISTICS<br />
MAXIMUM OPERATIONAL CURRENT<br />
TC<br />
Voltage Contactor Maximum current Ie [A] in categories:<br />
Ue DC1 with L/R ≤ 1ms DC3 - DC5 with L/R ≤ 15ms<br />
and poles in series<br />
and poles in series<br />
Type 1 2 3 4 1 2 3 4<br />
≤ 24V BG06 9 12 14 -- 6 7 9 --<br />
BG09 12 15 16 16 7 8 10 10<br />
BG12 12 15 16 -- 7 8 10 --<br />
BF09A - BF9C 15 18 20 20 10 13 15 15<br />
BF12A - BF12C 17 20 22 20❶ 12 15 18 15❶<br />
BF18A - BF16C 17 20 22 22 12 15 18 18<br />
BF25A - BF20C 20 23 23 -- 15 18 22 --<br />
BF26A - BF25C 25 28 28 28 18 20 25 30<br />
BF32A - BF32C 30 32 32 -- 20 25 30 --<br />
BF38A - BF40C 35 36 36 36 24 28 32 32<br />
BF50 45 60 60 60 30 35 50 55<br />
BF65 50 70 70 70 35 45 55 60<br />
BF80 70 100 100 100 40 60 80 90<br />
BF95 70 100 100 -- 40 60 80 --<br />
BF110 70 100 100 -- 40 60 80 --<br />
48V BG06 8 11 14 -- 5 7 9 --<br />
BG09 10 14 16 16 6 8 10 10<br />
BG12 10 14 16 -- 6 8 10 --<br />
BF09A - BF9C 13 18 20 20 9 11 15 15<br />
BF12A - BF12C 15 20 22 20❶ 11 13 18 15❶<br />
BF18A - BF16C 15 20 22 22 11 13 18 18<br />
BF25A - BF20C 18 23 23 -- 13 18 22 --<br />
BF26A - BF25C 21 28 28 28 15 20 25 30<br />
BF32A - BF32C 26 32 32 -- 17 22 28 --<br />
BF38A - BF40C 30 34 34 34 20 25 28 28<br />
BF50 40 60 60 60 25 35 50 55<br />
BF65 50 70 70 70 25 40 50 60<br />
BF80 60 100 100 100 30 50 70 90<br />
BF95 60 100 100 -- 30 55 75 --<br />
BF110 60 100 100 -- 30 55 75 --<br />
75V BG06 4 7 8 -- 2 4 5 --<br />
BG09 4 9 10 10 2 5 6 6<br />
BG12 4 9 10 -- 2 5 6 --<br />
BF09A - BF9C 12 17 20 20 8 10 13 15<br />
BF12A - BF12C 13 18 20 20❶ 10 12 15 15❶<br />
BF18A - BF16C 15 20 20 20 11 13 16 16<br />
BF25A - BF20C 18 23 23 -- 13 16 18 --<br />
BF26A - BF25C 18 25 25 25 13 18 20 25<br />
BF32A - BF32C 22 28 32 -- 15 20 28 --<br />
BF38A - BF40C 23 29 33 33 17 22 28 28<br />
BF50 40 60 60 60 22 30 45 55<br />
BF65 50 70 70 70 25 40 50 60<br />
BF80 60 100 100 100 30 50 70 90<br />
BF95 60 100 100 -- 30 50 70 --<br />
BF110 60 100 100 -- 30 50 70 --<br />
❶ Valid for BF12A only.<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com
®<br />
electric<br />
Technical characteristics<br />
IEC style contactors<br />
TC-9<br />
POLE CHARACTERISTICS<br />
MAXIMUM OPERATIONAL CURRENT<br />
Voltage Contactor Maximum current Ie [A] in categories:<br />
Ue DC1 with L/R ≤ 1ms DC3 - DC5 with L/R ≤ 15ms<br />
and poles in series<br />
and poles in series<br />
Type 1 2 3 4 1 2 3 4<br />
110V BG06 3 6 8 -- 1 3 4 --<br />
BG09 3 8 10 10 1 4 5 5<br />
BG12 3 8 10 -- 1 4 5 --<br />
BF09A - BF9C 6 12 15 16 2 7 11 12<br />
BF12A - BF12C 6 13 16 16❶ 2 8 12 12❶<br />
BF18A - BF16C 6 13 16 18 2 8 12 13<br />
BF25A - BF20C 6 16 18 -- 2 10 15 --<br />
BF26A - BF25C 6 22 24 24 2 13 18 20<br />
BF32A - BF32C 8 25 27 -- 2.5 15 20 --<br />
BF38A - BF40C 8 32 34 34 2.5 18 23 23<br />
BF50 8 50 55 60 3 25 30 45<br />
BF65 8 60 60 70 3 30 35 50<br />
BF80 8 80 85 100 3 40 60 75<br />
BF95 8 80 85 -- 3 40 60 --<br />
BF110 8 80 85 -- 3 40 60 --<br />
160V BG06 -- 4 6 -- -- 3 3 --<br />
BG09 -- 4 8 8 -- 2 4 4<br />
BG12 -- 4 8 -- -- 2 4 --<br />
220V BF09A - BF9C 4 8 10 12 0.75 1.5 5 7<br />
BF12A - BF12C 4 8 11 12❶ 0.75 1.5 6 7❶<br />
BF18A - BF16C 4 8 11 13 0.75 1.5 6 8<br />
BF25A - BF20C 4 8 12 -- 0.75 1.5 8 --<br />
BF26A - BF25C 5 12 14 14 0.75 1.5 10 15<br />
BF32A - BF32C 5 14 16 -- 1 3 12 --<br />
BF38A - BF40C 5 20 26 26 1 4 15 15<br />
BF50 6 36 45 50 1 5 20 25<br />
BF65 6 36 50 60 1 5 25 30<br />
BF80 6 40 55 70 1 7 35 40<br />
BF95 6 40 55 -- 1 7 35 --<br />
BF110 6 40 55 -- 1 7 35 --<br />
300V BF09A - BF9C -- -- -- 10 -- -- -- 5<br />
BF12A -- -- -- 10 -- -- -- 5<br />
BF18A - BF16C -- -- -- 11 -- -- -- 5<br />
BF26A - BF25C -- -- -- 16 -- -- -- 10<br />
BF38A - BF40C -- -- -- 25 -- -- -- 12<br />
BF50 -- -- -- 45 -- -- -- 20<br />
BF65 -- -- -- 60 -- -- -- 25<br />
BF80 -- -- -- 70 -- -- -- 35<br />
❶ Valid for BF12A only.<br />
TC<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com
TC-10<br />
Technical characteristics<br />
IEC style contactors<br />
®<br />
electric<br />
DC utilization<br />
category<br />
POLE CHARACTERISTICS<br />
MAXIMUM OPERATIONAL CURRENT<br />
TC<br />
Voltage Contactor Maximum current Ie [A] in categories:<br />
Ue DC1 with L/R ≤ 1ms DC3 - DC5 with L/R ≤ 15ms<br />
and poles in series<br />
and poles in series<br />
Type 1 2 3 4 1 2 3 4<br />
75V B115 160 160 160 160 140 140 140 140<br />
B145 220 220 220 220 160 160 160 160<br />
B180 260 260 260 260 180 180 180 180<br />
B250 350 350 350 350 280 280 280 280<br />
B310 375 375 375 375 310 310 310 310<br />
B400 400 400 400 400 350 350 350 350<br />
B500 650 650 650 650 550 550 550 550<br />
B630 800 800 800 800 800 800 800 800<br />
110V B115 100 130 130 130 70 100 120 120<br />
B145 110 150 150 150 80 120 140 140<br />
B180 120 170 170 170 90 140 160 160<br />
B250 160 300 300 300 150 250 280 280<br />
B310 195 350 350 350 170 290 310 310<br />
B400 250 400 400 400 200 350 350 350<br />
B500 320 550 600 600 320 550 550 550<br />
B630 460 800 800 800 460 800 800 800<br />
220V B115 -- 100 130 130 -- 80 100 120<br />
B145 -- 130 150 150 -- 90 120 140<br />
B180 -- 150 170 170 -- 100 140 160<br />
B250 -- 250 300 300 -- 200 250 280<br />
B310 -- 300 350 350 -- 230 290 310<br />
B400 -- 350 400 400 -- 280 350 350<br />
B500 -- 450 600 600 -- 450 550 550<br />
B630 -- 700 800 800 -- 700 800 800<br />
330V B115 -- -- 100 130 -- -- 80 120<br />
B145 - - 130 150 -- -- 90 140<br />
B180 -- -- 150 170 -- -- 100 160<br />
B250 -- -- 250 300 -- -- 200 280<br />
B310 -- -- 300 350 -- -- 230 310<br />
B400 -- -- 350 400 -- -- 280 350<br />
B500 -- -- 450 600 -- -- 450 550<br />
B630 -- -- 700 750 -- -- 650 700<br />
460V B115 -- -- -- 100 -- -- -- 80<br />
B145 -- -- -- 130 -- -- -- 90<br />
B180 -- -- -- 150 -- -- -- 100<br />
B250 -- -- -- 250 -- -- -- 200<br />
B310 -- -- -- 300 -- -- -- 230<br />
B400 -- -- -- 350 -- -- -- 280<br />
B500 -- -- -- 450 -- -- -- 450<br />
B630 -- -- -- 700 -- -- -- 700<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com
®<br />
electric<br />
Technical characteristics<br />
IEC style contactors<br />
TC-11<br />
Selection guide for<br />
lighting circuit<br />
switching<br />
GENERAL INFORMATION<br />
The elements which are to be considered for the contactor<br />
choice are:<br />
– Type of lamp<br />
– Power factor (cosϕ)<br />
– With or without power factor correction<br />
– Value of current when switching on and in running<br />
conditions<br />
Depending on the number and type of lamps, it is also<br />
important to bear in mind the main discriminating<br />
characteristics given below for the contactor choice:<br />
– Incandescent lamps → contactor making capacity<br />
– Lamps not corrected → rated contactor current in AC1<br />
– Lamps corrected → rated contactor current in AC3<br />
The table below summarises the major characteristics<br />
depending on the more commonly used type of lamps:<br />
TC<br />
Type of lamps Switching on Switching off<br />
Multiple of In❶ cosϕ Multiple of In❶ cosϕ<br />
Incandescent 15 1 1 1<br />
Mixed light 1.3 1 1 1<br />
Fluorescent 1.15 - 1.3 0.2 1 0.3 - 0.5 (not corrected)<br />
1 (corrected)<br />
High-pressure mercury vapor 1.5 - 1.75 0.2 1 0.45 - 0.7 (not corrected)<br />
High-pressure sodium vapor 1.3 - 1.5 0.2 1 0.3 - 0.5 (not corrected)<br />
Low-pressure sodium vapor 1 0.2 - 0.5 1 0.2 - 0.5 (not corrected)<br />
Metal halide 1.7 - 2.1 0.2 1 0.4 - 0.5 (not corrected)<br />
Lamp<br />
features<br />
Maximum current [A] per contactor pole<br />
BF09A<br />
BF9C<br />
BF12A<br />
BF12A BF20C BF26A BF80<br />
BG09 BF16C BF25A BF32A BF38A BF95<br />
BG12 BF18A BF25C BF32C BF40C BF50 BF65 BF110 B115 B145 B180<br />
INCANDESCENT<br />
120-240V 50/60Hz<br />
MIXED LIGHT<br />
120-240V 50/60Hz<br />
8.1<br />
9.2<br />
13<br />
15<br />
25<br />
26<br />
32<br />
35<br />
35<br />
40<br />
55<br />
55<br />
65<br />
65<br />
80<br />
80<br />
100<br />
110<br />
115<br />
140<br />
125<br />
170<br />
ELECTRONIC BALLAST FLUORESCENT<br />
120-240V 50/60Hz<br />
Single mounting<br />
Double mounting<br />
STANDARD FLUORESCENT<br />
120-240V 50/60Hz<br />
Not corrected, single mounting<br />
Corrected, single mounting<br />
Duo mounting ❶<br />
HIGH-PRESSURE MERCURY VAPOR<br />
120-240V 50/60Hz<br />
Not corrected<br />
Corrected<br />
380-415V 50/60Hz<br />
Not corrected<br />
Corrected<br />
HIGH-PRESSURE MERCURY VAPOR<br />
120-240V 50/60Hz<br />
Not corrected<br />
Corrected<br />
LOW-PRESSURE SODIUM VAPOR<br />
120-240V 50/60Hz<br />
Not corrected<br />
Corrected<br />
METAL HALIDE<br />
120-240V 50/60Hz<br />
Not corrected<br />
Corrected<br />
380-415V 50/60Hz<br />
Not corrected<br />
Corrected<br />
5<br />
5<br />
9<br />
6<br />
14<br />
6.8<br />
5.6<br />
––<br />
––<br />
6<br />
––<br />
7.2<br />
––<br />
––<br />
––<br />
––<br />
––<br />
8<br />
8<br />
15<br />
10<br />
15<br />
10<br />
10<br />
––<br />
––<br />
9.4<br />
7.5<br />
10<br />
3.6<br />
10<br />
8<br />
––<br />
––<br />
16<br />
16<br />
26<br />
16<br />
26<br />
17<br />
16<br />
8<br />
5.5<br />
15<br />
12<br />
16<br />
5<br />
15<br />
10.5<br />
––<br />
6.6<br />
22<br />
22<br />
35<br />
23<br />
40<br />
22<br />
22<br />
16<br />
11<br />
22<br />
16<br />
22<br />
7.2<br />
21<br />
12<br />
10<br />
6.6<br />
22<br />
22<br />
40<br />
23<br />
40<br />
27<br />
25<br />
16<br />
11<br />
27<br />
17<br />
27<br />
9.6<br />
27<br />
15<br />
10<br />
6.6<br />
40<br />
40<br />
55<br />
50<br />
55<br />
40<br />
40<br />
24<br />
22<br />
40<br />
38<br />
40<br />
26<br />
40<br />
40<br />
21<br />
23<br />
45<br />
45<br />
65<br />
51<br />
65<br />
45<br />
45<br />
24<br />
28<br />
45<br />
44<br />
45<br />
26<br />
45<br />
44<br />
21<br />
23<br />
50<br />
50<br />
80<br />
51<br />
80<br />
50<br />
50<br />
32<br />
28<br />
49<br />
44<br />
50<br />
26<br />
50<br />
50<br />
31<br />
26<br />
75<br />
75<br />
110<br />
110<br />
110<br />
75<br />
75<br />
40<br />
44<br />
75<br />
75<br />
75<br />
72<br />
75<br />
70<br />
41<br />
40<br />
105<br />
105<br />
140<br />
120<br />
140<br />
105<br />
105<br />
64<br />
61<br />
107<br />
103<br />
105<br />
72<br />
105<br />
75<br />
62<br />
46<br />
120<br />
120<br />
170<br />
125<br />
170<br />
120<br />
120<br />
72<br />
72<br />
120<br />
120<br />
120<br />
72<br />
120<br />
80<br />
72<br />
46<br />
❶ DUO mounting or circuit with improved power factor (power factor improvement is obtained by matching an inductive circuit to a capacitive circuit); refer to side<br />
figure.<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com
0<br />
TC-12<br />
Technical characteristics<br />
IEC style contactors<br />
®<br />
electric<br />
TC<br />
Power factor<br />
correction<br />
capacitors<br />
CHOICE CRITERIA<br />
The contactor during the closing transition is influenced by<br />
electrical currents having high frequencies and high<br />
amplitudes.<br />
The frequencies of these currents range between 1 and<br />
10kHz; the amplitudes must have values lower than the<br />
maximum permissible current peak of the contactor to be<br />
used.<br />
AMBIENT OPERATING CONDITIONS<br />
Ambient temperature: ≤120°F (50°C).<br />
For temperatures higher than 50°C up to 160°F/70°C, stated<br />
maximum operational power ratings are to be reduced by a<br />
percentage equal to the difference between the ambient<br />
temperature and 120°F/50°C.<br />
Operating cycle: ≤ 120 cy/h<br />
<strong>Electric</strong>al life: ≥ 100,000 cycles.<br />
1<br />
L1 L2 L3<br />
FU1<br />
R<br />
1 3 5 .1 .1<br />
KM1<br />
2 4 6 .2 .2<br />
U V W<br />
SELECTION GUIDE<br />
Contactor Rated Maximum Maximum Fuse Maximum operational power<br />
current permissible operational sc/gG at voltages:<br />
peak voltage 220V<br />
current 230V 380V 415V 500V<br />
240V 400V 440V 660/690V<br />
Type [A] [A] [V] [A] [kvar] [kvar] [kvar] [kvar]<br />
BF09A-BF9 12 500 690 16 4.5 7.5 9 10<br />
BF12A 16 550 690 25 6 11 12 14<br />
BF12-BF16<br />
BF18A-BF20 22 1000 690 32 9 15 16 18<br />
BF25A 22 1000 690 32 9 15 16 18<br />
BF26A-BF25 30 1400 690 40 11 20 22 22<br />
BF32A-BF32 38 1700 690 50 14 25 27 30<br />
BF38A-BF40 42 1900 690 63 16 28 30 34<br />
BF50 60 2500 690 80 23 40 44 50<br />
BF65 70 2700 690 100 26 45 50 56<br />
BF80 90 3000 690 125 34 60 65 70<br />
BF95 90 3000 690 125 34 60 65 70<br />
BF110 90 3000 690 125 34 60 65 70<br />
B115 130 3200 1000 200 50 87 93 115<br />
B145 150 3400 1000 200 57 100 108 130<br />
B180 170 3600 1000 250 65 112 122 150<br />
B250 240 5100 1000 315 91 158 172 210<br />
B310 265 5900 1000 315 105 184 200 245<br />
B400 320 7500 1000 400 122 211 230 280<br />
B500 500 9000 1000 630 190 330 360 430<br />
B630 610 11000 1000 800 230 400 432 520<br />
The use of contactors with the above operational powers is<br />
allowable only when the peak current, in the installation point<br />
of the power factor correction board, is lower than the values<br />
stated in the table.<br />
If this condition is not verified, it is necessary to use limiting<br />
inductances or specific contactors stated on page 3-8.<br />
Contact Sales & Technical Support to obtain detailed<br />
information on the correct use of contactors without limiting<br />
inductances.<br />
LIMITING INDUCTANCES<br />
The use of limiting inductances is imperative when the system<br />
inductances (line transformer and cables), upstream of the<br />
power factor correction panel, are not able to maintain the<br />
maximum connecting current within the limit value of the<br />
contactor used.<br />
FAST DISCHARGE RESISTANCES OF CAPACITORS<br />
The use of the contactor, according to the wiring diagram<br />
given, allows the fast discharge of the capacitors as well as<br />
the instantaneous disconnection of the capacitors from the<br />
mains when the coil is de-energised.<br />
The resistances, indicated in the following table, guarantee the<br />
discharge within a maximum time of 2 seconds.<br />
Capacitor power Voltage 220-230V Voltage 380-500V<br />
[kvar] [Ω] [W] [Ω] [W]<br />
2.5-5 3900 12 8200 12<br />
10-15 1800 25 4300 25<br />
20-50 1000 50 2200 50<br />
SCHEMA INSERZIONE RESISTENZE PER LA RAPIDA SCARICA DEI CONDENSATORI<br />
Disegno N? BM315<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com
®<br />
electric<br />
Technical characteristics<br />
IEC style contactors<br />
TC-13<br />
Special contactors<br />
for power factor<br />
correction<br />
capacitors<br />
GENERAL CHARACTERISTICS<br />
These contactors are equipped with early-make contacts. This<br />
special type of contact has the purpose of connecting for a<br />
very brief interval, 2-3ms, during the contactor closing,<br />
resistors which limit the connecting current of the capacitors.<br />
These resistors are then excluded when the closing operation<br />
is complete and the current capacity is conveyed to the main<br />
contacts. With this type of circuit, it is possible to obtain<br />
minor wear of all the components of the system especially<br />
fuses and capacitors ensuring a longer life and better<br />
reliability.<br />
The contactors are particularly suitable for use in automatic<br />
power factor correction panels since there is no need of<br />
limiting inductances and a source of heat has been eliminated.<br />
In this way, these modular electric switchboards can be more<br />
compact.<br />
The BF..K version, figure 1, is designed for three-phase<br />
switching. The peculiarity of this type is in the contacts,<br />
suitable to connect limiting resistors, which close only for the<br />
time needed to limit any in-rush current peak and them reopen<br />
to avoid eventual flow of residual currents through the<br />
resistors.<br />
OPERATING CONDITIONS<br />
Ambient temperature: ≤ +120°F (+50°C)<br />
For ambient temperature higher than +120°F/+50°C up to<br />
+160°F/+70°C, maximum operational power ratings, indicated<br />
in the table, are to be reduced by a percentage equal to the<br />
difference between the ambient temperature and<br />
+120°F/+50°C.<br />
Operating cycles: ≤ 120 cy/h<br />
<strong>Electric</strong>al life: ≥ 200,000 cycles<br />
TC<br />
L1 L2 L3<br />
1 3 5<br />
A1<br />
A2<br />
2 4 6<br />
T1 T2 T3<br />
Figure 1<br />
CHOICE OF CONTACTORS TYPE BFK<br />
Contactor Built-in Rated Fuse Maximum operational power<br />
auxiliary current sc/gG at voltages❶<br />
contacts<br />
220V<br />
NO 230V 380V 415V 500V<br />
240V 400V 440V 690V<br />
Type n° [A] [A] [kvar] [kvar] [kvar] [kvar]<br />
BFK09A 1 12 16 4.5 7.5 9 10<br />
BFK12A 1 18 25 7 12.5 14 16<br />
BFK18A 1 23 40 9 15 17 20<br />
BFK26A –– 30 40 11 20 22 22<br />
BFK32A –– 36 63 14 25 27.5 30<br />
BFK38A –– 43 63 17 30 33 36<br />
BF50K –– 58 80 22 38 41 46<br />
BF65K –– 70 100 26 45 50 56<br />
BF70K –– 75 125 30 50 56 65<br />
BF80K –– 90 125 34 60 65 70<br />
NOTE: See page 3-8 for catalog numbers.<br />
❶ Consult Sales & Technical Support for the use of contactors to switch within delta connection.<br />
CHOICE OF CONTACTORS TYPE BF...K ACCORDING TO UL LISTING<br />
Contactor Built-in Rated Fuse Maximum operational power<br />
auxiliary current at voltages❶<br />
contacts NO SC/gG 240V 480V 600V<br />
Type n° [A] [A] [kvar] [kvar] [kvar]<br />
BFK09A 1 12 16 4.5 9 10<br />
BFK12A 1 16 25 7 14 16<br />
BFK18A 1 22 40 9 17 20<br />
BFK26A –– 26.5 40 11 22 27.6<br />
BFK32A –– 36 63 15 27.5 32<br />
BFK38 –– 40 63 17 33 36<br />
BF50K –– 58 80 22 41 46<br />
BF65K –– 68 100 26 50 56<br />
BF70K –– 72 125 30 60 65<br />
BF80K –– 78 125 34 65 70<br />
NOTE: See page 3-8 for catalog numbers.<br />
❶ Consult Sales & Technical Support for the use of contactors to switch<br />
within delta connection.<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com
TC-14<br />
Technical characteristics<br />
IEC style contactors<br />
®<br />
electric<br />
TC<br />
Operational<br />
characheristics<br />
BG00 and BF00<br />
TYPE<br />
POLE CHARACTERISTICS<br />
Poles n°<br />
Conventional free air<br />
thermal current Ith (≤105°F/40°C)<br />
Rated insulation voltage Ui<br />
Frequency limit<br />
Designation of auxiliary contacts<br />
per UL/CSA, IEC/EN 60947-5-1 ❸<br />
Terminals in. (mm)<br />
quick-connect<br />
Min-Max tightening torque for contact<br />
terminals<br />
Min-Max tightening torque<br />
for coil terminals<br />
A<br />
B<br />
A<br />
V<br />
Hz<br />
AC<br />
DC<br />
A<br />
B<br />
screw<br />
Phillips<br />
Faston<br />
Nm<br />
lbft<br />
Nm<br />
lbft<br />
Phillips<br />
4<br />
10 10<br />
690<br />
25 - 400 ❶<br />
A600<br />
A600<br />
Q600<br />
Q600<br />
0.3 (7.5) 0.33 (8.3)<br />
0.16 (4) 0.14 (3.5)<br />
M3 M3.5<br />
2 2<br />
1-0.25 (6.35) or 2-0.11 (2.8) ––<br />
0.8-1 1.4-1.8<br />
0.59-0.74 1.03-1.33<br />
0.8-1 0.8-1<br />
0.59-0.74 0.59-0.74<br />
2 2<br />
Maximum conductor section<br />
connectable with 1 or 2 wires AWG n°<br />
10 10<br />
Flexible w/o mm 2<br />
0.75-2.5 6<br />
lug (min-max)<br />
Flexible mm 2<br />
1-2.5 or 2-1 6<br />
c/w lug<br />
Terminal protection per IEC/EN 60529<br />
AMBIENT CONDITIONS<br />
Operating temperature °F<br />
IP20❷<br />
-40 to +140 (-40 to +60°C)<br />
IP20❷<br />
-40 to +140 (-40 to +70°C)<br />
Storage temperature °F -65 to +160 (-55 to +70°C) -65 to +160 (-55 to +80°C)<br />
Maximum altitude<br />
ft<br />
9800 (3000m) 9800 (3000m)<br />
Operation position<br />
Normal<br />
Allowable<br />
On vertical plane<br />
±30°<br />
On vertical plane<br />
±30°<br />
Fixing<br />
Screw or 35mm DIN rail (IEC/EN 60715)<br />
❶ Derating for use at 61-400 Hz. Contact our Sales & Technical Support.<br />
❷ IP20 protection warranted by wired equipment; minimum 18 AWG/0.75mm 2 conductor section for BG00 or 18 AWG/1mm 2 for BF00.<br />
❸ See details on page TC-25.<br />
BG00<br />
BF00<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com
®<br />
electric<br />
Technical characteristics<br />
IEC style contactors<br />
TC-15<br />
TYPE<br />
A.C. control<br />
Rated control voltage at 60Hz<br />
V<br />
Operating voltage limits pick-up % Us<br />
drop-out % Us<br />
Average coil 50Hz in rush/holding VA<br />
consumption at<br />
≤70°F/20°C<br />
60Hz in rush/holding VA<br />
Dissipation at 70°F/20°C<br />
W<br />
DC CONTROL<br />
Rated control voltage<br />
V<br />
Operating voltage pick-up % Us<br />
limits drop-out % Us<br />
Average consumption at<br />
W<br />
≤70°F/20°C (in-rush/holding)<br />
OPERATING TIMES<br />
For control in AC closing NO ms<br />
opening NO ms<br />
closing NC ms<br />
opening NC ms<br />
DC closing NO ms<br />
opening NO ms<br />
closing NC ms<br />
opening NC ms<br />
LIFE<br />
Mechanical (millions)<br />
cycles<br />
MAXIMUM OPERATING RATE<br />
Mechanical operations<br />
cycles/h<br />
❶ 2.3W for low-consumption BG00...L version.<br />
BG00<br />
BF00<br />
12 - 575 12 - 600<br />
75 - 115 80 - 110<br />
20 - 55 40 - 55<br />
30/4 65/9<br />
25/3.0 78/10.8<br />
0.95 2.5<br />
6 - 250 -––<br />
75 - 115 ––<br />
10 - 20 ––<br />
3.2❶ ––<br />
12 - 21 8 - 24<br />
9 - 18 10 - 20<br />
17 - 26 17 - 30<br />
7 - 17 7 - 18<br />
18 - 25 ––<br />
2 - 3 ––<br />
3 - 5 ––<br />
11 - 17 ––<br />
20 20<br />
3600 3600<br />
TC<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com
TC-16<br />
Technical characteristics<br />
IEC style contactors<br />
®<br />
electric<br />
TC<br />
Operational<br />
characteristics<br />
BG06, BG09 and<br />
BG12<br />
TYPE<br />
POLE CHARACTERISTICS<br />
Power poles n°<br />
Rated insulation voltage Ui<br />
Rated impulse withstand voltage Uimp kV<br />
Operational frequency<br />
Hz<br />
Operational Conventional free air A<br />
current thermal Ith (≤105°F/40°C)<br />
AC3 (≤440V ≤130°F/55°C) A<br />
AC4 (400V) ❸<br />
A<br />
Short-time allowable current<br />
A<br />
for 10s (IEC/EN 60947-1)<br />
Max fuse size<br />
Type 1 or 2 SC/gG A<br />
aM<br />
A<br />
Making capacity (RMS value)<br />
A<br />
Breaking capacity ≤ 440V A<br />
at voltage<br />
500V A<br />
690V A<br />
Consumption per<br />
mΩ<br />
pole and resistance<br />
Ith<br />
W<br />
(average values)<br />
AC3 W<br />
Terminals in. (mm)<br />
A<br />
B<br />
screw<br />
A<br />
Phillips<br />
quick-connect Faston<br />
solder<br />
Maximum tightening torque<br />
for contact and coil terminals<br />
V<br />
Nm<br />
lbft<br />
Phillips<br />
Maximum conductor section connectable<br />
with 1 or 2 wires<br />
AWG n°<br />
Flexible w/o mm 2<br />
lug (min-max)<br />
Flexible mm 2<br />
c/w lug<br />
Terminal protection per IEC/EN60529<br />
AMBIENT CONDITIONS<br />
Operating temperature °F<br />
Storage temperature °F<br />
Maximum altitude<br />
ft<br />
Operating<br />
Normal<br />
position<br />
Allowable<br />
Fixing<br />
❶ Rated voltage Ui for BGP and BGS are 500V only; BGP is UL rated at 300V while BGS at 600V.<br />
❷ Derating for use at 61-400Hz. Contact Sales & Technical Support.<br />
❸ Current values guarantee an electrical life of about 50,000 cycles.<br />
❹ Dimensions and drilling distances are given on page D-4.<br />
❺ IP20 protection warranted by wired equipment; minimum 18 AWG / 0.75mm 2 conductor section.<br />
B<br />
BG06 BG09 BG12 - DPBG12<br />
3 3-4 3<br />
690 ❶<br />
6<br />
25 - 400 ❷<br />
16 20 20<br />
6 9 12<br />
3.3 4.0 4.8<br />
96<br />
16 20 20<br />
6 10 16<br />
92 92 120<br />
72 72 96<br />
72 72 72<br />
72 72 72<br />
10 10 10<br />
2.6 4 4<br />
0.36 0.81 1.44<br />
0.3 (7.5) 0.3 (7.5) 0.3 (7.5)<br />
0.16 (4) 0.16 (4) 0.16 (4)<br />
M3 M3 M3<br />
2 2 2<br />
–– 1-0.25 (6.35) ––<br />
or 2-0.11 (2.8)<br />
–– PCB pin❹ PCB pin❹<br />
0.8-1 0.8-1 0.8-1<br />
0.59-0.74 0.59-0.74 0.59-0.74<br />
2<br />
10<br />
0.75-2.5<br />
2 - 1 or 1 - 2.5<br />
IP20❺<br />
-40 to +140 (-40 to +60°C)<br />
-65 to +160 (-55 to +70°C)<br />
9800 (3000m)<br />
On vertical plane<br />
± 30°<br />
Screw or 35mm DIN rail (IEC/EN 60715)<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com
®<br />
electric<br />
Technical characteristics<br />
IEC style contactors<br />
TC-17<br />
TYPE<br />
AC CONTROL<br />
Rated control voltage from V<br />
at 60Hz<br />
to V<br />
Operating<br />
from % Us<br />
voltage limits pick-up<br />
to % Us<br />
drop-out<br />
from % Us<br />
to % Us<br />
Coil consumption<br />
in-rush VA<br />
at ≤70°F/20°C 60Hz<br />
holding VA<br />
Dissipation at ≤70°F/20°C<br />
W<br />
DC CONTROL<br />
Rated control from V<br />
voltage<br />
to V<br />
Operating<br />
from % Us<br />
voltage limits pick-up<br />
to % Us<br />
drop-out<br />
from % Us<br />
to % Us<br />
Average consumption<br />
W<br />
OPERATING TIMES<br />
With closing NO ms<br />
control<br />
opening NO ms<br />
AC<br />
closing NC ms<br />
opening NC ms<br />
closing NO ms<br />
DC<br />
opening NO ms<br />
closing NC ms<br />
opening NC ms<br />
LIFE (millions)<br />
Mechanical AC control cycles<br />
DC control<br />
cycles<br />
<strong>Electric</strong>al (Ie at 400V AC3)<br />
cycles<br />
MAXIMUM OPERATING CYCLE<br />
Mechanical<br />
cy/h<br />
❶ 2.3W for low-consumption type BG...L<br />
BG06 BG09 BG12 - DPBG12<br />
12 12 12<br />
575 575 575<br />
75 75 75<br />
115 115 115<br />
20 20 20<br />
55 55 55<br />
25 25 25<br />
3.0 3.0 3.0<br />
0.95 0.95 0.95<br />
6 6 6<br />
250 250 250<br />
75 75 75<br />
115 115 115<br />
10 10 10<br />
25 25 25<br />
32 3.2❶ 3.2<br />
12 - 21 12 - 21 12 - 21<br />
9 - 18 9 - 18 9 - 18<br />
17 - 26 17 - 26 17 - 26<br />
7 - 17 7 - 17 7 - 12<br />
18 - 25 18 - 25 18 - 25<br />
2 - 3 2 - 3 2 - 3<br />
3 - 5 3 - 5 3 - 5<br />
11 - 17 11 - 17 11 - 17<br />
20 20 20<br />
20 20 20<br />
0.5 0.5 0.5<br />
3600 3600 3600<br />
TC<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com
TC-18<br />
Technical characteristics<br />
IEC style contactors<br />
®<br />
electric<br />
TC<br />
Operational<br />
characteristics<br />
BF09A-BF38A with<br />
AC control circuit<br />
TYPE<br />
BF09A BF12A BF18A BF25A BF26A BF32A BF38A<br />
DPBF09A DPBF12A DPBF18A –– DPBF26A DPBF32A ––<br />
POLE CHARACTERISTICS<br />
Power poles n° 3-4 3-4 3-4 3 3-4 3 3-4<br />
Rated insulation voltage Ui<br />
V<br />
690<br />
Rated impulse withstand votage Uimp kV<br />
8<br />
Operational frequency<br />
Hz<br />
25-400❶<br />
Operational Conventional free air A 25 28 32 32 45 56 56<br />
current thermal Ith (≤105°F/40°C)<br />
AC3 (≤440V ≤130°F/55°C) A 9 12 18 25 26 32 38<br />
AC4 (400V)❷<br />
A 4.9 7.9 8.5 10 11.5 13.5 15.5<br />
Short-time allowable current for 10s<br />
(IEC/EN 60947-1)<br />
A 110 110 130 160 200 320 320<br />
Max fuse size SC/gG A 32 40 40 50 50 63 80<br />
Type 1 or 2 aM A 10 12 16 25 32 32 40<br />
Making capacity (RMS value) A<br />
250 250 250 250 480 480 480<br />
Breaking capacity<br />
at voltage ≤440V A 250 250 250 250 480 480 480<br />
Consumption and<br />
mΩ 2.5 2.5 2.5 2.5 2.0 2.0 2.0<br />
resistance per pole<br />
Ith W 1.6 2.0 2.6 2.6 4.0 6.0 6.0<br />
(average values)<br />
AC3 W 0.2 0.4 0.8 1.6 1.4 2.0 2.9<br />
Terminals in. (mm)<br />
Type<br />
Clamp-screw<br />
A<br />
0.37 (9.5) 0.51 (13)<br />
B<br />
0.17 (4) 0.22 (5.5)<br />
A<br />
Screw M3.5 M3.5 M3.5 M3.5 M4 M4 M4<br />
Phillips 2 2 2 2 2 2 2<br />
Min-Max tightening torque<br />
Nm 1.5-1.8 1.5-1.8 1.5-1.8 1.5-1.8 2.5-3 2.5-3 2.5-3<br />
for contact terminal<br />
Ibft 1.1-1.5 1.1-1.5 1.1-1.5 1.1-1.5 1.8-2.2 1.8-2.2 1.8-2.2<br />
Min-Max tightening torque<br />
Nm 0.8-1 0.8-1 0.8-1 0.8-1 0.8-1 0.8-1 0.8-1<br />
for coil terminals<br />
lbft 0.59-0.74 0.59-0.74 0.59-0.74 0.59-0.74 0.59-0.74 0.59-0.74 0.59-0.74<br />
Phillips 2 2 2 2 2 2 2<br />
Maximum conductor section<br />
connectable with 1 or 2 wires<br />
AWG n° 16-10 16-10 16-10 16-10 14-6 14-6 14-6<br />
Flexible w/o lug<br />
(min-max) mm 2 1-6 1-6 1-6 1-6 2.5-16 2.5-16 2.5-16<br />
Flexible c/w lug mm 2 1-4 1-4 1-4 1-4 1-10 1-10 1-10<br />
Power terminal protection<br />
per IEC/EN 60529<br />
IP20❸ IP20❸ IP20❸ IP20❸ IP20❹ IP20❹ IP20❹<br />
AMBIENT CONDITIONS<br />
Operating temperature °F<br />
-60 to +160 (-50 to +70°C)<br />
Storage temperature °F<br />
-75 to +175 (-60 to +80°C)<br />
Maximum altitude<br />
ft<br />
9800 (3000m)<br />
Operating<br />
Normal<br />
On vertical plane<br />
position<br />
Allowable<br />
± 30°<br />
Fixing<br />
Screw or 35mm DIN rail (IEC/EN 60715)<br />
B<br />
❶ Derating for use at 61-400Hz. Contact Sales & Technical Support.<br />
❷ Current values guarantee an electrical life of about 200,000 cycles.<br />
❸ IP20 protection warranted by wired equipment; minimum 18 AWG / 1mm 2 conductor section.<br />
❹ IP20 protection warranted by wired equipment; minimum 6 AWG / 16mm 2 conductor section.<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com
®<br />
electric<br />
Technical characteristics<br />
IEC style contactors<br />
TC-19<br />
TYPE<br />
AC CONTROL<br />
Rated control voltage from V<br />
at 60Hz<br />
to V<br />
Operating limits<br />
from % Us<br />
pick-up<br />
to % Us<br />
drop-out<br />
from % Us<br />
to % Us<br />
Average coil cosumption in-rush VA<br />
at ≤70°F/20°C holding VA<br />
Dissipation at ≤70°F/20°C<br />
W<br />
OPERATING TIMES<br />
With control closing NO ms<br />
in AC<br />
opening NO ms<br />
closing NC ms<br />
opening NC ms<br />
LIFE (millions)<br />
Mechanical AC control cycles<br />
<strong>Electric</strong>al (Ie at 400V AC3)<br />
cycles<br />
MAXIMUM OPERATING RATE<br />
Mechanical operations<br />
cy/h<br />
BF09A BF12A BF18A BF25A BF26A BF32A BF38A<br />
DPBF09A DPBF12A DPBF18A –– DPBF26A DPBF32A ––<br />
12 12 12 12 12 12 12<br />
600 600 600 600 600 600 600<br />
80 80 80 80 80 80 80<br />
110 110 110 110 110 110 110<br />
20 20 20 20 20 20 20<br />
55 55 55 55 55 55 55<br />
70 70 70 70 70 70 70<br />
6.5 6.5 6.5 6.5 6.5 6.5 6.5<br />
2.5 2.5 2.5 2.5 2.5 2.5 4.5<br />
8-24 8-24 8-24 8-24 8-24 8-24 14-27<br />
10-20 10-20 10-20 15-20 15-20 15-20 8-18<br />
17-30 17-30 17-30 16-22 -- -- --<br />
7-18 7-18 7-18 7-18 -- -- --<br />
20 20 20 20 20 20 20<br />
2.0 2.0 1.6 1.2 1.6 1.6 1.4<br />
3600<br />
TC<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com
TC-20<br />
Technical characteristics<br />
IEC style contactors<br />
®<br />
electric<br />
TC<br />
Operational<br />
characteristics<br />
BF9-BF40 with AC<br />
or DC control<br />
circuit<br />
TYPE<br />
POLE CHARACTERISTICS<br />
Power poles n°<br />
Rated insulation voltage Ui<br />
V<br />
Rated impulse withstand votage Uimp kV<br />
Operational frequency<br />
Hz<br />
Operational Conventional free air<br />
current thermal Ith (≤105°F/≤40°C) A<br />
AC3 (≤440V ≤130°F/≤55°C) A<br />
AC4 (400V)❹<br />
A<br />
Short-time allowable current for 10s<br />
(IEC/EN 60947-1)<br />
A<br />
BF9C BF12C BF16C BF20C BF25C BF32C BF40C❶ BF40C 40❷<br />
3-4 3 3-4 3 3-4 3 3 4<br />
690<br />
8<br />
25-400❸<br />
25 25 25 40 40 55 60 60<br />
9 12 16 20 25 32 40 40<br />
5.3 7.2 7.5 10 11.7 16 20 20<br />
110 110 130 160 200 320 320 320<br />
Max fuse size SC/gG A 32 40 40 50 50 63 80 80<br />
Type 1 or 2 aM A 10 12 16 20 25 32 40 40<br />
Making capacity (RMS value) A<br />
210 210 210 350 350 480 480 480<br />
Breaking capacity ≤440V A 210 210 210 350 350 480 480 480<br />
at voltage<br />
500V A 160 160 160 290 290 320 320 320<br />
690V A 120 120 120 220 220 270 270 270<br />
Consumption and<br />
mΩ 5 5 5 2.5 2.5 2.0 1.8 1.8<br />
resistance per pole<br />
Ith W 3.1 3.1 3.1 4.0 4.0 6.0 6.5 6.5<br />
(average values)<br />
AC3 W 0.40 0.72 1.3 1.0 1.6 2.0 2.6 2.6<br />
Terminals in. (mm)<br />
Type<br />
Clamp-screw<br />
A<br />
0.32 (8.3) 0.4 (10.1) 0.52 (13.2)<br />
B<br />
0.14 (3.5) 0.23 (5.9) 0.22 (5.5)<br />
A<br />
Screw M3.5 M3.5 M3.5 M4 M4 M5 M5 M5<br />
Phillips 2 2 2 2 2 2 2 2<br />
Min-Max tightening torque<br />
Nm 1.4-1.8 1.4-1.8 1.4-1.8 1.8-2.3 1.8-2.3 3.1-3.9 3.1-3.9 3.1-3.9<br />
for contact terminal<br />
Ibft 1.03-1.33 1.03-1.33 1.03-1.33 1.32-1.70 1.32-1.70 2.24-2.88 2.24-2.88 2.24-2.88<br />
Min-Max tightening torque<br />
Nm 0.8-1 0.8-1 0.8-1 0.8-1 0.8-1 0.8-1 0.8-1 0.8-1<br />
for coil terminals<br />
lbft 0.59-0.74 0.59-0.74 0.59-0.74 0.59-0.74 0.59-0.74 0.59-0.74 0.59-0.74 0.59-0.74<br />
Phillips 2 2 2 2 2 1 1 1<br />
Maximum conductor section<br />
connectable with 1 or 2 wires<br />
AWG n° 10 10 10 8 8 4 4 4<br />
Flexible w/o lug<br />
(min-max) mm 2 1-6 1-6 1-6 1.5-10 1.5-10 2.5-16 2.5-16 2.5-16<br />
Flexible c/w lug mm 2 6 6 6 6 6 6 6 6<br />
Power terminal protection<br />
according to EN 60529<br />
IP20❺ IP20❺ IP20❺ IP20❻ IP20❻ IP20❼ IP20❼ ––<br />
AMBIENT CONDITIONS<br />
Operating temperature<br />
Storage temperature<br />
Maximum altitude<br />
°F<br />
°F<br />
ft<br />
-60 to +160 (-50 to +70°C)<br />
-75 to +175 (-60 to +80°C)<br />
9800 (3000m)<br />
Operating<br />
position<br />
Fixing<br />
Normal<br />
Allowable<br />
On vertical plane<br />
± 30°<br />
Screw or 35mm DIN rail (IEC/EN 60715)<br />
❶ Three-pole version.<br />
❷ Four-pole version, 4NO type (main poles). For data of the 2NO+2NC type, contact Sales & Technical Support.<br />
❸ Derating for use at 61-400Hz. Contact Sales & Technical Support.<br />
❹ Current values guarantee an electrical life of about 200,000 cycles.<br />
❺ IP20 protection warranted by wired equipment; minimum 18 AWG / 1mm 2 conductor section.<br />
❻ 14 AWG / 2.5mm 2 conductor section for 3-pole type or 10 AWG / 6mm 2 for 4-pole type<br />
❼ IP20 protection warranted by wired equipment; minimum 6 AWG / 16mm 2 conductor section.<br />
B<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com
®<br />
electric<br />
Technical characteristics<br />
IEC style contactors<br />
TC-21<br />
TYPE<br />
DC CONTROL<br />
Rated control from V<br />
voltage<br />
to V<br />
Operating<br />
from % Us<br />
voltage limits pick-up<br />
to % Us<br />
drop-out<br />
from % Us<br />
to % Us<br />
Average coil consumption<br />
W<br />
OPERATING TIMES<br />
With control closing NO ms<br />
in DC<br />
opening NO ms<br />
AC<br />
closing NC ms<br />
opening NC ms<br />
LIFE (millions)<br />
Mechanical DC control cycles<br />
<strong>Electric</strong>al (Ie at 400V AC3) cycles<br />
MAXIMUM OPERATING CYCLE<br />
Mechanical operations<br />
cy/h<br />
BF9C BF12C BF16C BF20C BF25C BF32C BF40C❶ BF40C 40❷<br />
12 12 12 12 12 12 12 12<br />
600 600 600 600 600 600 600 600<br />
80 80 80 80 80 80 80 80<br />
120 120 120 120 120 120 120 110<br />
15 15 15 15 15 15 15 15<br />
25 25 25 25 25 25 25 25<br />
9 9 9 9 9 9 9 15<br />
42-58 42-58 42-58 42-58 42-58 42-58 42-58 58-80<br />
7-13 7-13 7-13 7-13 7-13 5-10 5-10 11-16<br />
11-17 11-17 11-17 11-17 11-17 -- -- --<br />
32-42 32-42 32-42 28-38 28-38 -- -- --<br />
20 20 20 20 20 20 20 20<br />
2.0 2.0 1.7 1.7 1.7 1.6 1.6 1.6<br />
3600<br />
❶ Three-poloe version.<br />
❷ Four-pole version, 4NO type (power poles). For data of the 2NO+2NC type, contact Sales & Technical Support.<br />
TC<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com
TC-22<br />
Technical characteristics<br />
IEC style contactors<br />
®<br />
electric<br />
TC<br />
Operational<br />
characteristics<br />
BF50-BF110<br />
TYPE<br />
POLE CHARACTERISTICS<br />
Power poles n°<br />
Rated insulation voltage Ui<br />
V<br />
Rated impulse withstand votage Uimp kV<br />
Operational frequency<br />
Hz<br />
Operational Conventional free air<br />
current thermal Ith (≤105°F/40°C) A<br />
AC3 (≤440V ≤130°F/55°C) A<br />
AC4 (400V)❸<br />
A<br />
Short-time allowable current for 10s<br />
(IEC/EN 60947-1)<br />
A<br />
Max fuse size SC/gG A<br />
Type 1 or 2 aM A<br />
Making capacity (RMS value) A<br />
Breaking capacity ≤440V A<br />
at voltage<br />
500V A<br />
690V A<br />
Consumption and<br />
mΩ<br />
resistance per pole<br />
Ith W<br />
(average values)<br />
AC3 W<br />
Terminals in. (mm)<br />
Type<br />
A<br />
B<br />
Screw<br />
A<br />
Metric<br />
Allen<br />
Min-Max tightening torque<br />
Nm<br />
for contact terminal<br />
Ibft<br />
Min-Max tightening torque<br />
Nm<br />
for coil terminals<br />
lbft<br />
Phillips<br />
Maximum conductor section<br />
connectable with 1 or 2 wires<br />
AWG n°<br />
Flexible w/o lug<br />
(min-max) mm 2<br />
Flexible c/w lug mm 2<br />
Power terminal protection<br />
according to IEC/EN 60529<br />
AMBIENT CONDITIONS<br />
Operating temperature °F<br />
Storage temperature °F<br />
Maximum altitude<br />
ft<br />
Operating<br />
Normal<br />
position<br />
Allowable<br />
Fixing<br />
B<br />
BF50 BF65 BF80 BF95 BF110<br />
3-4 3-4 3-4 3 3<br />
1000❶<br />
8<br />
25 - 400❷<br />
90 110 125 125 125<br />
50 65 80 95 110<br />
28 31 38 43 43<br />
390 390 480 760 880<br />
100 125 160 160 160<br />
50 80 80 100 125<br />
800 1090 1200 1200 1200<br />
800 1090 1200 1200 1200<br />
660 830 1050 1050 1050<br />
500 630 800 800 800<br />
0.8 0.8 0.6 0.6 0.6<br />
6.5 9.7 9.4 9.4 9.4<br />
2.0 3.4 3.8 5.4 7.3<br />
Lug clamp❹<br />
0.48 (12.3)<br />
0.47 (12)<br />
M6<br />
4<br />
4-5<br />
2.95-3.69<br />
0.8-1<br />
0.59-0.74<br />
1<br />
2/0<br />
4-50 4-50 6-50 6-50 6-50<br />
4-50 4-50 6-50 6-50 6-50<br />
IP20❺<br />
-60 to +160 (-50 to +70°C)<br />
-75 to +175 (-60 to +80°C)<br />
9800 (3000m)<br />
On vertical plane<br />
± 30°<br />
Screw or DIN rail 35mm ❻ and 75mm (IEC/EN 60715)<br />
❶ Rated insulation voltage Ui for 4-pole types is 690V.<br />
❷ Derating for use at 61-400 Hz. Contact Sales & Technical Support.<br />
❸ Current values guarantee an electrical life of about 200,000 cycles.<br />
❹ In addition the main terminal, the following dimensions refer to the second entry of flexible busbars: 0.48x0.15in (12.3x3.8mm).<br />
❺ IP20 protection warranted to three-pole contactors only by mounting the G265 protection.<br />
❻ Only three-pole versions can be mounted on 35mm DIN rail.<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com
®<br />
electric<br />
Technical characteristics<br />
IEC style contactors<br />
TC-23<br />
TYPE<br />
AC CONTROL<br />
Rated control voltage from V<br />
at 60Hz<br />
to V<br />
Operating voltage<br />
from % Us<br />
limits<br />
pick-up<br />
to % Us<br />
at ≤70°F/20°C<br />
from % Us<br />
drop-out<br />
to % Us<br />
Average coil in-rush VA<br />
consumption holding VA<br />
Dissipation at ≤70°F/20°C<br />
W<br />
DC CONTROL<br />
Rated control from V<br />
voltage<br />
to V<br />
Operating<br />
from % Us<br />
voltage limits pick-up<br />
to % Us<br />
drop-up<br />
from % Us<br />
to % Us<br />
Average coil consumption ≤70°F/20°C W<br />
(in-rush - holding)<br />
OPERATING TIMES<br />
With closing NO ms<br />
control AC<br />
opening NO ms<br />
DC<br />
closing NO ms<br />
opening NO ms<br />
LIFE (millions)<br />
Mechanical AC control cycles<br />
DC control cycles<br />
Elettrica (Ie at 400V in AC3) cycles<br />
MAXIMUM OPERATING CYCLE<br />
Mechanical operations<br />
cy/h<br />
BF50 BF65 BF80 BF95 BF110<br />
12 12 12 12 12<br />
660 660 660 660 660<br />
80 80 80 80 80<br />
110 110 110 110 110<br />
20 20 20 20 20<br />
55 55 55 55 55<br />
252 252 252 252 252<br />
21.6 21.6 21.6 21.6 21.6<br />
6 6 6 6 6<br />
12 12 12 12 12<br />
660 660 660 660 660<br />
80 80 80 80 80<br />
110 110 110 110 110<br />
10 10 10 10 10<br />
25 25 25 25 25<br />
15 15 15 15 15<br />
13-25 13-25 13-25 13-25 13-25<br />
8-12 8-12 8-12 8-12 8-12<br />
60-90 60-90 60-90 60-90 60-90<br />
7-12 7-12 7-12 7-12 7-12<br />
15 15 15 15 15<br />
15 15 15 15 15<br />
1.5 1.4 1.3 1.2 0.8<br />
3600<br />
TC<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com
B<br />
TC-24<br />
Technical characteristics<br />
IEC style contactors<br />
®<br />
electric<br />
TC<br />
Operational<br />
characteristics<br />
B115-B1600<br />
TYPE<br />
POLE CHARACTERISTICS<br />
Power poles n°<br />
Rated insulation voltage Ui<br />
V<br />
Rated impulse withstand votage Uimp kV<br />
Operational frequency<br />
Hz<br />
Operational Conventional free air<br />
current thermal Ith (≤70°F/40°C) A<br />
AC3 (≤440V ≤130°F/55°C) A<br />
AC4 (400V)❷<br />
A<br />
Short-time allowable current for 10s<br />
(IEC/EN 60947-1)<br />
A<br />
Max fuse size SC/gG A<br />
Type 1 or 2 aM A<br />
Making capacity (RMS value) A<br />
Breaking capacity ≤440V A<br />
at voltage<br />
500V A<br />
690V A<br />
1000V A<br />
Consumption and<br />
mΩ<br />
resistance per pole<br />
Ith W<br />
(average values)<br />
AC3 W<br />
Terminals in. (mm)<br />
A<br />
A<br />
B<br />
B115 B145 B180 B250 B310 B400 B500 B630<br />
3-4 3-4 3-4 3-4 3-4 3-4 3-4 3-4 3-4 3-4 3-4<br />
1000<br />
8<br />
25-400❶<br />
160 250 275 350 450 550 700 800 1000 1250 1600<br />
110 150 185 265 320 420 520 630 – – –<br />
47 57 65 92 110 133 175 210 – – –<br />
1100 1300 1500 2200 2900 3600 4050 5040 5600 6500 8300<br />
200 250 315 400 500 630 800 1000 ❸ ❸ ❸<br />
125 160 200 250 400 400 500 630 – – –<br />
1100 1500 1850 2750 3150 4200 5000 6300 ❸ ❸ ❸<br />
1300 1500 1850 2500 3000 4000 5000 6300 ❸ ❸ ❸<br />
1100 1400 1600 2250 2700 3400 4500 5600 ❸ ❸ ❸<br />
880 1200 1480 2200 2520 3360 4000 5000 ❸ ❸ ❸<br />
600 800 1000 1500 1700 2300 2700 3400 ❸ ❸ ❸<br />
0.30 0.30 0.30 0.20 0.20 0.20 0.14 0.14 0.14 0.07 0.07<br />
7.7 14.5 20.3 24.5 40.5 52.0 68.6 90 140 110 180<br />
4.0 6.8 9.7 12.5 20 32 35.0 56 – – –<br />
0.6 0.8 0.8 1 1 1 1.4 1.6 2.4 3.1 3.1<br />
(15) (20) (20) (25) (25) (25) (35) (40) (60) (80) (80)<br />
0.16 0.16 0.16 0.2 0.2 0.2 0.24 0.24 0.24 0.4 0.4<br />
(4) (4) (4) (5) (5) (5) (6) (6) (6) (10) (10)<br />
Screw<br />
+ hex<br />
nut M6 M8 M8 M10 M10 M10 M10 M12 2-M12 2-M12 2-M12<br />
Maximum conductor section<br />
in 0.8x0.1 1x0.1 1x0.1 1.2x0.2 1.2x0.2 1.2x0.2 2x0.2 2.4x0.2 2.4x0.2 4x0.2 4x0.2<br />
connectable 1 or 2 bars mm 20x3 25x3 25x3 30x4 30x5 30x5 50x5 60x5 60x5 100x5 100x5<br />
N° 1 wire<br />
with lug mm 2 70 120 150 240 -- -- -- -- – – –<br />
N° 2 wire<br />
with lug mm 2 -- -- -- -- 150 150 240 240 – – –<br />
AMBIENT CONDITIONS<br />
Operating temperature<br />
Storage temperature<br />
Maximum altitude<br />
°F<br />
°F<br />
ft<br />
-60 to +160 (-50 to +70°C)<br />
-75 to +175 (-60 to +80°C)<br />
9800 (3000m)<br />
Operating<br />
position<br />
Fixing<br />
Normal<br />
Allowable<br />
On vertical plane<br />
± 30°<br />
Screw<br />
❶ Derating for use at 61-400 Hz. Contact Sales & Technical Support.<br />
❷ Current values guarantee an electrical life of about 200,000 cycles.<br />
❸ Consult Sales & Technical Support.<br />
B630<br />
1000<br />
B1250<br />
B1600<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com
®<br />
electric<br />
Technical characteristics<br />
IEC style contactors<br />
TC-25<br />
Operational<br />
characteristics<br />
B115-B1600<br />
TYPE<br />
B630<br />
B115 B145 B180 B250 B310 B400 B500 B630<br />
1000<br />
B1250 B1600<br />
AC CONTROL<br />
Supply voltage<br />
The electromagnet can operate either in AC or DC<br />
AC only<br />
Rated control voltage<br />
V 24-480 24-480 24-480 24-480 24-480 24-480 48-480 48-480 48-480 110-480 110-480<br />
Operating pick-up % Us 80-110 80-110 80-110 80-110 80-110 80-110 80-110 80-110 80-110 80-110 80-110<br />
voltage limits<br />
drop-out % Us 20-60 30-60 30-60 30-60 30-60 30-60 30-60 30-60 30-60 30-60 30-60<br />
Consumption in-rush VA/W 300 300 300 300 300 300 400 400 400 800 800<br />
at ≤70°F/20°C holding VA/W 10 10 10 10 10 10 18 18 18 40 40<br />
Dissipation at ≤70°F/20°C<br />
W 10 10 10 10 10 10 18 18 18 40 40<br />
OPERATING TIMES<br />
Making<br />
ms 60-100 60-100 60-100 80-120 80-120 80-120 110-180 110-180 110-180 120-210 120-210<br />
Breaking<br />
ms 25-60 25-60 25-60 30-75 30-75 30-75 60-100 60-100 60-110 70-130 70-130<br />
LIFE (millions)<br />
Mechanical<br />
cycles 10 10 10 10 10 10 5 5 5 5 5<br />
<strong>Electric</strong>al (Ie at 400V in AC3) cycles 1.1 1.1 1.0 1 0.7 0.7 0.7 0.7 – – –<br />
MAXIMUM OPERATING CYCLE<br />
Mechanical operations<br />
cy/h 2400 2400 2400 2400 2400 2400 1200 1200 1200 1200 1200<br />
PARTICULAR CHARACTERISTICS<br />
Indicator<br />
Safety feature<br />
Contactor open or closed<br />
Closing operations are prevented without arc chutes<br />
CONTROL CIRCUIT UTILISATION<br />
The input electronic circuit of the contactor coil B115-B1600 is designed and tested according to IEEEC 62.41 and can withstand a<br />
10 kV impulse voltage (1.2/50µs) with 50 Joule energy.<br />
For higher values, the use of an auxiliary reduced voltage transformer is recommended.<br />
TC<br />
Operational<br />
characteristics of<br />
incorporated<br />
auxiliary contacts<br />
of types BG00,<br />
BG06, BG09, BG12,<br />
BF09A-BF25A,<br />
BF9C-BF25C, DPBG,<br />
DPBF...A<br />
TYPE<br />
CHARACTERISTICS<br />
Thermal current Ith<br />
Rated insulation voltage Ui<br />
Terminals<br />
Screw<br />
Width<br />
Faston❸<br />
A<br />
V<br />
in<br />
in<br />
Maximum conductor section<br />
connectable with 1 or 2 wires<br />
Flexible w/o lug (min-max) mm 2<br />
Flexible c/w lug (min-max) mm 2<br />
AWG n°<br />
UL/CSA<br />
AC<br />
designation<br />
DC<br />
BG00-BG06-BG09-BG12 BF00A-BF09A-BF25A❶ BF20C-BF25C❷<br />
DPBG12❶ DPBF09A-DPBF12A-DPBF18A❶<br />
BF9C-BF12C-BF16C❷<br />
10 10 10<br />
690 690 690<br />
M3 M3.5 M4<br />
0.3 (7.5mm) 0.33 (8.3mm) 0.4 (10.1mm)<br />
1-0.25 (6.35mm) –– ––<br />
2-0.11 (2.8mm)<br />
0.75-2.5 1-6 1.5-10<br />
2-1 or 1-2.5 6 6<br />
10 10 8<br />
A600 A600 A600<br />
Q600 P600❹ P600<br />
❶ The NO and NC auxiliary contacts of BG mini-contactors and BF...A or DPBF...A contactors are highly conductive.<br />
❷ The NC auxiliary contacts of BF9C, BF12C and BF16C contactors are highly conductive.<br />
❸ For BG00 and BG09 types only.<br />
❹ Q600 for BF9C-BF12C-BF16C types.<br />
Rating data for control-circuit contacts per UL508<br />
UL designation Thermal Maximum Amperes (AC at 60Hz) Maximum VA<br />
continuous 120VAC 240VAC 480VAC 600VAC<br />
test current<br />
Make Break Make Break Make Break Make Break Make Break<br />
A600 10 60 6 30 3 15 1.5 12 1.2 7200 720<br />
Maximum Amperes (DC) Make or Break<br />
Maximum VA<br />
Make or Break<br />
125VDC 250VDC 301-600DC 300V or less<br />
P600 5 1.1 0.55 0.2 138<br />
Q600 2.5 0.55 0.27 0.1 69<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com
TC-26<br />
Technical characteristics<br />
IEC style contactors<br />
®<br />
electric<br />
TC<br />
Positively guided<br />
contacts for types<br />
with incorporated<br />
auxiliary contacts<br />
Positively guided contacts are a requirement in safety circuits<br />
to correctly monitor the status of normally open contacts.<br />
Guided contacts imply that Normally Open (NO) and Normally<br />
Closed (NC) will operate together reciprocally but can never be<br />
simultaneously closed, even in case of NO contacts weld. This<br />
requirement is obtained by particular constructional details,<br />
such as reduced gap tolerance through which the mobile<br />
contact travels and the points of actuation are closer to the<br />
actual contact position.<br />
Positively Guided Contacts are also called positively safety<br />
contacts, forced contacts, linked contacts, force or positive<br />
guided or positively driven contacts.<br />
The positively guided contacts assume different meanings and<br />
terminologies in compliance with the product standards which<br />
are given below.<br />
IEC 60947-4-1/A1 ed. 2 - Annex F<br />
In this case, positively guided contacts are called auxiliary<br />
contacts linked with power contacts (mirror contact).<br />
The requirement is that when power poles weld, the auxiliary<br />
NC contacts remain open.<br />
This requirement is standard supplied on all our contactors<br />
having an integrated NC auxiliary contacts:<br />
BG...01, BF09 01A, BF12 01A, BF18 01A, BF25 01A,<br />
BF9C...01, BF12C...01, BF16C...01, BF20C...01, BF25C...01,<br />
DPBG12, DPBF09A, DPBF12A, DPBF18A types.<br />
PHYSICAL PROPERTIES OF MIRROR CONTACT<br />
DE-ENERGIZED<br />
MIRROR CONTACT<br />
CONVENTIONAL<br />
NC CONTACT<br />
NC<br />
mirror contact<br />
NO<br />
power contacts<br />
NC NO<br />
contact power contacts<br />
(monitoring)<br />
ENERGIZED<br />
NC<br />
mirror contact<br />
(monitoring)<br />
NO<br />
power contacts<br />
NC NO<br />
contact power contacts<br />
(monitoring)<br />
DE-ENERGIZED<br />
WELD<br />
WELD<br />
NC<br />
mirror contact<br />
(monitoring)<br />
WILL<br />
REMAIN<br />
OPEN<br />
NO<br />
power contacts<br />
NC<br />
contact<br />
(monitoring)<br />
WILL<br />
CLOSE<br />
NO<br />
power contacts<br />
IEC 60947-5-1/A2 ed. 2 - Annex L<br />
In this case, positively guided contacts are called<br />
mechanically linked contacts.<br />
The requirement is that NO and NC contacts can never be<br />
simultaneously closed, even if the NO contact or NC contact<br />
welds in closed position.<br />
This requirement applies to auxiliary safety contacts included<br />
in control circuit devices where the actuating positively is<br />
provided internally; therefore, this does not apply to push<br />
buttons or limit switches.<br />
Lovato control relays, such as BG00 and BF00, which have at<br />
least one NO and one NC contact, fall into this category.<br />
(See Physical properties of mechanically linked contacts on<br />
page TC-27).<br />
Note:<br />
Control circuit devices, operated externally (e.g. push-button or limit-switches) can not have mechanically linked contact elements.<br />
Such devices, in safety applications, generally have contacts with Direct Opening Actuation.<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com
®<br />
electric<br />
Technical characteristics<br />
IEC style contactors<br />
TC-27<br />
Positively guided<br />
contacts for add-on<br />
auxiliary contact<br />
blocks<br />
IEC 60947-5-1/A2 ed. 2 - Annex L<br />
In this case, positively guided contacts are called<br />
mechanically linked contacts.<br />
The requirement is that NO and NC contacts can never be<br />
simultaneously closed, even if the NO contact or NC contact<br />
welds in closed position.<br />
This requirement applies to auxiliary safety contacts included<br />
in control circuit devices where the actuating positively is<br />
provided internally; therefore, this does not apply to push<br />
buttons or limit switches.<br />
Several auxiliary contact blocks, which have at least one NO<br />
and one NC contact, fall into this category. These blocks<br />
include:<br />
BGX10 11, BGX10 31, BGX10 22, BGX10 13, BGX11 11,<br />
BGX11 12, BGXF10 11, BGXF10 13, BGXF10 22, BGXF10 31,<br />
BFX10 11, BFX10 13, BFX10 22, BFX10 31, G350, G354,<br />
G481 11, G484 12 and G484 21.<br />
TC<br />
PHYSICAL PROPERTIES OF MECHANICAL LINKED CONTACTS<br />
MECHANICALLY<br />
LINKED CONTACT<br />
CONVENTIONAL CONTACT<br />
DE-ENERGIZED<br />
NC<br />
contacts<br />
(monitoring)<br />
NO<br />
contacts<br />
NC<br />
contacts<br />
(monitoring)<br />
NO<br />
contacts<br />
ENERGIZED<br />
NC<br />
contacts<br />
(monitoring)<br />
NO<br />
contacts<br />
NC<br />
contacts<br />
(monitoring)<br />
NO<br />
contacts<br />
DE-ENERGIZED<br />
WELD<br />
WELD<br />
NC<br />
contacts<br />
(monitoring)<br />
WILL<br />
REMAIN<br />
OPEN<br />
NC<br />
contacts<br />
(monitoring)<br />
WILL<br />
CLOSE<br />
NO<br />
contacts<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com
TC-28<br />
Technical characteristics<br />
IEC style contactors: add-on blocks and accessories<br />
®<br />
electric<br />
TC<br />
Maximum<br />
combination<br />
BF types<br />
POSITION AND MAXIMUM QUANTITY OF ADD-ON BLOCKS<br />
AND ACCESSORIES<br />
For application at maximum composition, at temperatures<br />
>104°F/40°C and DC control, contact Sales Technical<br />
Support.<br />
CONTACTORS<br />
CONTACTORS<br />
BF00A-BF09A-BF12A-BF18A-BF25A-BF26A-BF32A-BF38A BF40C 40-BF40C 22<br />
DPBF09A-DPBF12A-DPBF18A-DPBF26A-DPBF32A<br />
BF50-BF65-BF80-BF95-BF110 3/4 POLES<br />
BF9C-BF12C-BF16C-BF20C-BF25C-BF32C-BF40C<br />
Area A Area B/C❶ Area B1/C1❸ Area A Area B/C❼ Area B1/C1❼<br />
B1<br />
B<br />
A<br />
C1<br />
C<br />
N° 1 BFX10 N° 1 G218 N° 1 G218+G280 N° 1 BFX10 N° 1 G218 N° 1 G218+G280<br />
or or or or or or<br />
N° 1 G484 N° 1 G318 N° 1 G428... N°1 G484 N° 1 G318 N° 1 G428<br />
or or or or or or<br />
N° 1 G485 N° 1 G319 N° 1 G481+G483 N° 1 G485 N° 1 G319 N° 1 G481+G483<br />
or or or or or or<br />
N° 1 G486 N° 1 G322 N° 1 G482+G483 N° 1 G486 N° 1 G322 N° 1 G482+G483<br />
or or or or or or<br />
N° 1 G487 N° 1 G418 N° 1 G418+G419 N° 1 G487 N° 1 G418 N° 1 G418+G419<br />
or or or<br />
N° 1 G481 N° 1 BFX50 00❹ N° 1 G481<br />
or<br />
or<br />
N° 1 G482 N° 1 G482<br />
or<br />
or<br />
N° 1 G223❷ N° 1 G269 2<br />
or<br />
N° 1 G269 1❷<br />
or<br />
N° 1 BFX50 02❹<br />
or<br />
N° 1 BFX50 03❹<br />
CONTACTS WITH MECHANICAL LATCH<br />
CONTACTORS<br />
BF00A-BF09A-BF12A-BF18A-BF25A-BF26A-BF32A-BF38A<br />
BF9C-BF12C-BF16C-BF20C-BF25C-BF32C-BF40C<br />
Area A Area B/C Area B1/C1❸<br />
B1<br />
G222<br />
C1<br />
A<br />
N° 1 BFX10 N° 1 BFX50 02❹ N° 1 G218+G280❻<br />
or or or<br />
N° 1 G484 N° 1 G223❷ N° 1 G428❻<br />
or<br />
or<br />
N° 1 G485 N° 1 G481+G483❻<br />
or<br />
or<br />
N° 1 G486 N° 1 G482+G483❻<br />
or<br />
or<br />
N° 1 G487 N° 1 G418+G419❻<br />
or<br />
N° 1 BFX50 00❹<br />
or<br />
N° 1 BFX50 01❹<br />
or<br />
N° 1 BFX50 02❹<br />
or<br />
N° 1 G223❷<br />
CONTACTORS<br />
BF40C 40 - BF40C 22<br />
BF50-BF65-BF80-BF95-BF110 3/4 POLES<br />
Area A Area B/C❼ Area B1/C1❺<br />
B1<br />
B<br />
G272<br />
C1<br />
C<br />
A<br />
N° 1 BFX10 N° 1 G218 N° 1 G218+G280<br />
or or or<br />
N° 1 G484 N° 1 G318 N° 1 G428<br />
or or or<br />
N° 1 G485 N° 1 G319 N° 1 G481+G483<br />
or or or<br />
N° 1 G486 N° 1 G322 N° 1 G482+G483<br />
or or or<br />
N° 1 G487 N° 1 G418 N° 1 G418+G419<br />
or<br />
N° 1 G481<br />
or<br />
N° 1 G482<br />
or<br />
N° 1 G269 2<br />
❶ No contact block can be mounted in area B1 or C1 if add on blocks are<br />
mounted in area B or C.<br />
If BFX10... add-on block with 4 contacts is mounted in area A, no other<br />
add-on can be mounted in area B or C except for BFX50 02 on BF...A<br />
types or 11 G223 on BF...C types.<br />
❷ For old BF or DC type only.<br />
❸ When the fourth pole BFX42 is mounted or for 4-pole types BF26T,<br />
DPBF26T4 and BF38T, no add-on block can be mounted in area C1.<br />
❹ For BF...A and DPBF...A types only.<br />
❺ No side-mount blocks can be mounted on BF40 22 contactor.<br />
❻ For BF20C, BF25C, BF32C, BF40C, types only.<br />
❼ No contact block can be mounted in area B1 or C1 if add on blocks are<br />
mounted in area B or C.<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com
F<br />
E<br />
G<br />
D<br />
C<br />
A<br />
B<br />
®<br />
electric<br />
Technical characteristics<br />
IEC style contactors: add-on blocks and accessories<br />
TC-29<br />
Maximum<br />
combination<br />
B115-B630 1000<br />
AUXILIARY CONTACTS<br />
The add-on auxiliary contact blocks G350 and G354 can be<br />
applied to contactors B115-B630 1000 only up to a maximum<br />
of four pieces, for a total of 12 contacts. The<br />
contact block G350 provides a 2NO+1NC or 1NO+2NC<br />
combination depending on its mounting position; see the<br />
drawing delow. The G354 block consists of 1NO+1NC.<br />
G354<br />
G350<br />
G350<br />
G354<br />
TC<br />
53<br />
113<br />
54<br />
114<br />
61<br />
121<br />
62<br />
122<br />
22<br />
82<br />
21<br />
81<br />
14<br />
74<br />
13<br />
73<br />
or or<br />
41<br />
01<br />
42<br />
02<br />
53<br />
113<br />
54<br />
114<br />
61<br />
121<br />
62<br />
122<br />
94<br />
33<br />
93<br />
22<br />
82<br />
21<br />
81<br />
14<br />
74<br />
13<br />
73<br />
34<br />
73<br />
13<br />
74<br />
14<br />
81<br />
21<br />
82<br />
22<br />
93<br />
33<br />
94<br />
34<br />
122<br />
62<br />
121<br />
61<br />
114<br />
54<br />
113<br />
53<br />
02<br />
42<br />
01<br />
41<br />
or or<br />
73<br />
13<br />
74<br />
14<br />
81<br />
21<br />
82<br />
22<br />
122<br />
62<br />
121<br />
61<br />
114<br />
54<br />
113<br />
53<br />
G354<br />
G350<br />
G350<br />
G354<br />
Contact blocks, BFX10 with 2 contacts, G484, G485, G486 and<br />
G487 types, can be mounted using the G358 adapter, refer to<br />
page 3-14 for exact types and catalog numbers of the blocks.<br />
A maximum of four adapters can be possibly used per<br />
contactor and each adapter can hold one BFX10, G484, G485,<br />
G486 and G487.<br />
BFX10 20<br />
53 63<br />
BFX10 11<br />
93 01<br />
BFX10 02<br />
51 61<br />
54 64<br />
G484 30<br />
94 02<br />
G484 21<br />
52 62<br />
G484 12<br />
BFX10...<br />
53 63 73<br />
53 61 73<br />
53 61 71<br />
54 64 74<br />
54 62 74<br />
54 62 72<br />
G484...<br />
G484 03<br />
51 61 71<br />
G485...<br />
G486...<br />
G487...<br />
52 62 72<br />
G485 ...<br />
G486 ... - G487<br />
57<br />
65<br />
67<br />
55<br />
G371<br />
G358<br />
58<br />
66<br />
68<br />
56<br />
G358<br />
G358<br />
G358<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com
TC-30<br />
Technical characteristics<br />
IEC style contactors: add-on blocks and accessories<br />
®<br />
electric<br />
TC<br />
Fig.1<br />
MECHANICAL INTERLOCK BETWEEN CONTACTORS SIDE BY<br />
SIDE B115-B630 1000<br />
The G355 type can interlock contactors of the same size or of<br />
a different one (e.g.: B115 interlocked to B630).<br />
This interlock cannot be used with B1250 or B1600 contactor.<br />
MECHANICAL INTERLOCK BETWEEN CONTACTORS ONE ON<br />
TOP OF THE OTHER B115-B1600<br />
It is G356... which is provided in six types to allow different<br />
fixing interaxis of contactors. Contactors of the same size can<br />
be interlocked as well as different sizes.<br />
Consult Sales & Technical Support to interlock B630 1000<br />
three-pole contactors.<br />
The tables below indicate the interaxis which can be<br />
obtained with the various interlock types; with terminal<br />
protections (INTERAXIS A) and without terminal protection<br />
(INTERAXIS B).<br />
INTERAXIS A [mm] (in) - For contactors with terminal protection<br />
KM1<br />
KM1 B115-B145-B180 B250-B310-B400 B500-B630<br />
KM2 B115 B250 B500 B115 B250 B500 B115 B250 B500<br />
B145 B310 B630 B145 B310 B630 B145 B310 B630<br />
B180 B400 B180 B400 B180 B400<br />
G356 1 --- --- --- --- --- --- --- ---<br />
A<br />
G356..<br />
G356 2<br />
G356 3<br />
286-305 --- --- --- --- --- --- ---<br />
(11.26-12)<br />
305-345 330-345 --- 330-345 --- --- --- --- ---<br />
(12-13.6) (13-13.6) (13-13.6)<br />
G356 4<br />
345-385 345-385 375-385 345-385 375-385 --- 375-385 --- ---<br />
(13.6-15.15) (13.6-15.15) (14.8-15.15) (13.6-15.15) (14.8-15.15) (14.8-15.15)<br />
KM2<br />
G356 5<br />
G356 6<br />
390-425 390-425 390-425 390-425 390-425 420-425 390-425 420-425 ---<br />
(15.35-16.75) (15.35-16.75) (15.35-16.75) (15.35-16.75) (15.35-16.75) (16.5-16.75) (15.35-16.75) (15.35-16.75)<br />
470-500 470-500 470-500 470-500 470-500 470-500 470-500 470-500 470-500<br />
(18.5-19.7) (18.5-19.7) (18.5-19.7) (18.5-19.7) (18.5-19.7) (18.5-19.7) (18.5-19.7) (18.5-19.7) (18.5-19.7)<br />
INTERAXIS B [mm] (in) - For contactors without terminal protection<br />
KM1<br />
Fig.2<br />
KM1 B115-B145-B180 B250-B310-B400 B500-B630<br />
KM2 B115 B250 B500 B115 B250 B500 B115 B250 B500<br />
B145 B310 B630 B145 B310 B630 B145 B310 B630<br />
B180 B400 B180 B400 B180 B400<br />
225-265<br />
G356 1<br />
(8.85-10.4)<br />
--- --- --- --- --- --- --- ---<br />
B<br />
KM2<br />
G356..<br />
Fig.3<br />
G356 2<br />
G356 3<br />
G356 4<br />
G356 5<br />
G356 6<br />
265-305 265-305 --- 265-305 265-305<br />
(10.4-12) (10.4-12) (10.4-12) (10.4-12)<br />
--- --- --- ---<br />
305-345 305-345 305-345 305-345 305-345 305-345 305-345 305-345<br />
(12-13.6) (12-13.6) (12-13.6) (12-13.6) (12-13.6) (12-13.6) (12-13.6) (12-13.6)<br />
---<br />
345-385 345-385 345-385 345-385 345-385 345-385 345-385 345-385 345-385<br />
(13.6-15.15) (13.6-15.15) (13.6-15.15) (13.6-15.15) (13.6-15.15) (13.6-15.15) (13.6-15.15) (13.6-15.15) (13.6-15.15)<br />
390-425 390-425 390-425 390-425 390-425 390-425 390-425 390-425 390-425<br />
(15.35-16.75) (15.35-16.75) (15.35-16.75) (15.35-16.75) (15.35-16.75) (15.35-16.75) (15.35-16.75) (15.35-16.75) (15.35-16.75)<br />
470-500 470-500 470-500 470-500 470-500 470-500 470-500 470-500 470-500<br />
(18.5-19.7) (18.5-19.7) (18.5-19.7) (18.5-19.7) (18.5-19.7) (18.5-19.7) (18.5-19.7) (18.5-19.7) (18.5-19.7)<br />
To interlock two contactors B630 1000, use type G356 6 only; interaxis B is 470-500mm (18.5-19.7in), refer to fig. 4. To interlock<br />
two contactors B1250 or B1600, it is imperative to use two pieces of type G356 6, one fixed on the left side and the other on the<br />
right; interaxis B is 470-500mm (18.5-19.7in). The B1250 or B1600 cannot be interlocked with the other types of the B series.<br />
B<br />
BG356..<br />
Fig.4<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com
®<br />
electric<br />
Technical characteristics<br />
IEC style contactors: add-on blocks and accessories<br />
TC-31<br />
CONTACT BLOCKS APPLIABLE TO CONTACTORS WITH<br />
MECHANICAL INTERLOCK<br />
Auxiliary contact blocks G350 or G354 can be mounted<br />
according to the combinations below when the mechanical<br />
interlock is used (see parts in blue in figure 1) or the G358<br />
adapter with the auxiliary blocks as per the combinations<br />
given in figure 2.<br />
TC<br />
Fig. 1<br />
B115-B630<br />
B115-B180<br />
B250-B400<br />
B500-B630 1000<br />
Fig. 2<br />
B115-B630<br />
B115-B180<br />
B250-B400<br />
B500-B630 1000<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com
TC-32<br />
Technical characteristics<br />
IEC style overload relays<br />
®<br />
electric<br />
TC<br />
Operational<br />
characteristics<br />
thermal overload<br />
relays RF<br />
Phase failure sensitive hand reset RF9 RF38❶ RF25 RF95 RF200❶ RF420❶<br />
Phase failure sensitive automatic reset RFA9 RFS38❶ RFA25 RFA95<br />
Non phase failure sensitive hand reset RFS25 RFS95<br />
Non phase failure sensitive automatic reset<br />
POWER CIRCUIT CHARACTERISTICS<br />
Rated insulation voltage Ui V 690 690 690 690 1000 1000<br />
Rated impulse withstand voltage Uimp kV 8<br />
Frequency limit Hz 0 - 400 0 - 400 0 - 400 0 - 400 50 - 60 50 - 60<br />
Operational range from A 0.09 0.1 0.09 14 60 150<br />
to A 15 38 26 95 200 420 ❷<br />
Connection Direct With current transformers ❸<br />
Terminals<br />
Yoke<br />
Type Screw & washer clamp Screw & flat washer<br />
Screw M 4 M 4 M 4 M 5 M 8 (hex) M 10 (hex)<br />
Terminal width in 0.4 0.5 0.4 0.35 0.8 1<br />
(mm) (9.8) (12.6) (9.8) (9) (20) (25)<br />
Phillips n° 2 2 2 2 13mm❹ 18mm❹<br />
Tightening torque Nm 2.3 2...2.5 2.3 3.9 18 35<br />
for power terminals lbft 1.7 1.5...1.8 1.7 2.88 13.3 25.9<br />
Maximum conductor section connectable<br />
AWG n° 10 8 10 2 -- --<br />
flexible w/o lug mm 2 6 10 6 35 -- --<br />
flexible c/w lug mm 2 10 6 10 -- 150 2 - 150<br />
Bar<br />
in<br />
(mm) -- -- -- -- (25 x 3) (30 x 5)<br />
Dissipation per phase W 0.7 - 2.4 0.7 - 2.40 0.7 - 2.4 2 - 4.2 0.7 - 2.4 0.7 - 2.4<br />
AUXILIARY CIRCUIT CHARACTERISTICS<br />
Available NO n° 1<br />
contacts NC n° 1<br />
Rated insulation voltage V 690<br />
Conventional free air thermal current A 10<br />
Terminals with Screw M3.5<br />
screw and washer Terminal width 0.3 in (8mm)<br />
Phillips n° 1<br />
Maximum conductor section connectable<br />
Flexible w/o lug mm 2 2.5<br />
Flexible c/w lug mm 2 2.5<br />
Tightening torque Nm 1 1...1.5 1 1 1...1.5 1...1.5<br />
for auxiliary terminals lbft 0.74 0.74...1.1 0.74 0.74 0.74...1.1 0.74...1.1<br />
UL designation (IEC/EN 60947-5-1) AC-DC B600 - P600 B600-R300 B600-P600 B600-P600 B600-R300 B600-R300<br />
❺ ❺ ❺<br />
Operational current AC (220-230V) A 2.5<br />
DC (110V) A 1.1<br />
AMBIENT CONDITIONS<br />
Operating temperature °F -4 to +130 -13 to +140 -4 to +130 -4 to +130 -13 to +140 -13 to +140<br />
°C (-20 to +55) (-25 to +60) (-20 to +55) (-20 to +55) (-25 to +60) (-25 to +60)<br />
Storage temperature °F -65 to +160 -60 to +160 -65 to +160 -65 to +160 -60 to +160 -60 to +160<br />
°C (-55 to +70) (-50 to +70) (-55 to +70) (-55 to +70) (-50 to +70) (-50 to +70)<br />
Compensation temperature °F +5 to +160 -4 to +140 +5 to +160 +5 to +160 -4 to +140 -4 to +140<br />
°C (-15 to +55) (-20 to +60) (-15 to +55) (-15 to +55) (-20 to +60) (-20 tp +60)<br />
Maximum altitude ft 9800 (3000m)<br />
Operation position Normal On vertical plane<br />
Allowable ±30°<br />
Mounting<br />
On contactor or separately<br />
Tripping class<br />
10A<br />
Particular characteristics<br />
Test button - Trip indicator<br />
❶ With manual and automatic resetting.<br />
❷ For currents higher than 420A, contact Sales & Technical Support.<br />
❸ Standard supplied.<br />
❹ Metric wrench/spanner.<br />
❺ C600-R300 for automatic reset type.<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com
®<br />
electric<br />
Technical characteristics<br />
IEC style overload relays<br />
TC-33<br />
Trip characteristic<br />
curves<br />
RF thermal<br />
overload relays<br />
(average times)<br />
Three-phase balanced operation<br />
RF9 RF25 RF38 RF95<br />
RFA9 RFA25 RFA95<br />
4<br />
10<br />
8<br />
6<br />
4<br />
[s]<br />
Two-phase operation (phase failure)<br />
RF9 RF25 RF38 RF95<br />
RFA9 RFA25 RFS38 RFA95<br />
RFS9 RFS25 RFS95<br />
4<br />
[s]<br />
4<br />
10<br />
8<br />
6<br />
TC<br />
2<br />
2<br />
3<br />
10<br />
8<br />
6<br />
4<br />
3<br />
10<br />
8<br />
6<br />
4<br />
2<br />
2<br />
10<br />
8<br />
6<br />
4<br />
COLD<br />
2<br />
2<br />
10<br />
8<br />
6<br />
4<br />
COLD<br />
2<br />
2<br />
1<br />
10<br />
8<br />
6<br />
4<br />
HOT<br />
1<br />
10<br />
8<br />
6<br />
4<br />
HOT<br />
2<br />
2<br />
0.8 1 1.2 1.5 2 3 4 5 6 7 8 9 10 x le<br />
0.7 0.9 1.05<br />
0.8 1 1.2 1.5 2 3 4 5 6 7 8 9 10 x le<br />
0.7 0.9 1.05<br />
RF200<br />
RF420<br />
RF200<br />
RF420<br />
4<br />
10<br />
8<br />
6<br />
4<br />
[s]<br />
4<br />
[s]<br />
4<br />
10<br />
8<br />
6<br />
2<br />
2<br />
3<br />
10<br />
8<br />
6<br />
4<br />
3<br />
10<br />
8<br />
6<br />
4<br />
2<br />
2<br />
2<br />
10<br />
8<br />
6<br />
4<br />
COLD<br />
2<br />
10<br />
8<br />
6<br />
4<br />
COLD<br />
2<br />
2<br />
1<br />
10<br />
8<br />
6<br />
4<br />
HOT<br />
1<br />
10<br />
8<br />
6<br />
4<br />
HOT<br />
2<br />
2<br />
0.8 1 1.2 1.5 2 3 4 5 6 7 8 9 10 x le<br />
0.7 0.9 1.05<br />
0.8 1 1.2 1.5 2 3 4 5 6 7 8 9 10 x le<br />
0.7 0.9 1.05<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com
TC-34<br />
Technical characteristics<br />
Rotary cam switches<br />
®<br />
electric<br />
TC<br />
Operational<br />
characteristics<br />
Selection guide<br />
The choice of a rotary cam switch and the relative type are<br />
based on the functional diagram and the type of application as<br />
well.<br />
IEC standards provide a comprehensible and quick<br />
classification of the most frequent utilization categories:<br />
AC1: Connection and disconnection of non-inductive or<br />
slightly inductive loads (cosϕ ≥0.95)<br />
AC21: Resistance furnaces<br />
AC3: Starting and switching off motors during running<br />
AC23: Switching of motor loads or other highly inductive<br />
loads<br />
AC15: Control of electromagnetic loads<br />
For DC applications, the rotary cam switches are used for the<br />
switching of minor loads or in control circuits, such as:<br />
DC13: Control of electromagnets<br />
DC21A: Switching of resistive loads<br />
DC23: Switching of highly inductive loads<br />
Other prescriptions and recommendations concerning the use<br />
of cam switches as auxiliary equipment of electrical machines<br />
are given in IEC/EN 60204-1 standards and specifically as<br />
given under utilization.<br />
Utilization<br />
MAIN SUPPLY DISCONNECTING SWITCH WITH EMERGENCY-<br />
STOP OPERATION:<br />
– Red operating handle with yellow background<br />
– Lockable in open position (OFF).<br />
EMERGENCY-STOP SWITCH<br />
– Red operating handle with yellow background<br />
– Independent operation and the breaking of the load circuit<br />
of switching devices before the opening of its main<br />
contacts<br />
– Rated capacity is to sufficient in order to break the sum of<br />
the rated operating currents of all the connected equipment<br />
– Breaking capacity equal to the current of the largest motor<br />
when stalled (locked rotor) together with the total of the<br />
normal running currents of the other motors or loads.<br />
MAIN SUPPLY DISCONNECTING SWITCH<br />
– Used to disconnect all live electrical equipment from the<br />
power supply circuit<br />
– Contact clearance distance is to comply with<br />
IEC/EN 60947-3 standards<br />
– Provided with a means in order to be locked in the OFF<br />
position<br />
– Selection of current breaking according to AC1 and AC21<br />
utilization categories.<br />
TYPE<br />
Rated insulation voltage Ui❶<br />
IEC/EN<br />
UL/CSA<br />
Rated impulse withstand voltage Uimp ❶<br />
IEC/EN 60947-3<br />
Conventional free air thermal<br />
current Ith IEC/EN<br />
General purpose UL/CSA<br />
Rated operational voltage<br />
(disconnecting switch) ❶<br />
Operational impulse voltage<br />
IEC/EN 60947-1<br />
Maximum fuse size for<br />
10kA<br />
short-circuit protection In (gG) 25kA<br />
50kA<br />
63kA<br />
Short-time<br />
withstand current Icw<br />
1sec<br />
Rated operational current Ie<br />
AC1/AC21A (IEC/EN)<br />
110V<br />
AC15 (IEC/EN) 220-230V<br />
380-400V<br />
660-690V<br />
AC switching capacity<br />
AC3 (IEC/EN) 220-230V<br />
3 phases 380-440V<br />
500-690V<br />
1 phase (2 poles) 110V<br />
220-230V<br />
380-440V<br />
AC23A (IEC/EN) 220-230V<br />
3 phases 380-440V<br />
500-690V<br />
1 phase (2 poles) 110V<br />
220-230V<br />
380-440V<br />
V<br />
V<br />
kV<br />
A<br />
A<br />
V<br />
kV<br />
A<br />
A<br />
A<br />
A<br />
A<br />
A<br />
A<br />
A<br />
A<br />
A<br />
GX16 GX20 GX32 GX40 GN12 GN20 GN25 GN32 GN40 GN63 GN125<br />
690 690 690 690 690 690 690 690 690 690 690<br />
600 600 600 600 300 300 600 600 600 600 600<br />
6 6 6 6 6 6 6 6 6 6 8<br />
16 20 32 40 12 20 25 32 40 63 125<br />
12 15 32 40 10 15 20 32 35 55 100<br />
440 440 440 440 480 480 480 480 480 480 690<br />
4 4 4 4 4 4 4 4 4 4 6<br />
16 20 35 40 16 20 25 32 40 63 125<br />
16 16 35 35 10 16 25 32 40 63 100<br />
– – 32 35 – – – 32 40 63 100<br />
– – – 35 – – – – 40 63 100<br />
250 250 800 800 200 250 400 800 1000 1600 2100<br />
16 20 32 40 12 20 25 32 40 63 125<br />
10 10 25 25 10 10 16 25 25 32 40<br />
8 4 20 22 8 8 12 20 22 25 28<br />
4 6 10 12 4 6 8 10 12 15 15<br />
3 3.7 5.5 7.5 1.5 1.5 2 2 2 4 5<br />
kW 3.5 3.7 7.5 7.5 2.5 3 5.5 7.5 8 11 18.5<br />
kW 4.5 5.5 11 15 4 5.5 7.5 11 15 18.5 37<br />
kW 5.5 5.5 11 15 5.5 5.5 7.5 11 15 18.5 33<br />
kW 0.55 0.75 1.8 2.2 0.8 0.8 1.5 2.2 3 3.7 5<br />
kW 1.5 1.8 3.5 4.4 1.5 2.2 3 4 6.5 6.5 11<br />
kW 2.2 3 5.5 7 2.2 3 5.5 6.5 8 11.5 15<br />
kW 3.7 4 8 9 3 5 6.5 8 8 12.5 30<br />
kW 6.5 7.5 15 18.5 6 7.5 11 15 18.5 30 45<br />
kW 6.5 7.5 15 15 7.5 7.5 11 18.5 22 30 37<br />
kW<br />
0.75 0.75 2.2 3 0.8 0.8 1.5 2.2 3 3.7 5<br />
kW<br />
1.8 2.2 3.5 5.2 1.7 2.5 3.7 5 6 7.5 11<br />
kW<br />
3 3.5 6 7.5 3 3.7 5.5 8 11 12.5 15<br />
❶ Valid for systems with grounded neutral, overvoltage category III, pollution degree 3.<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com
®<br />
electric<br />
Technical characteristics<br />
Rotary cam switches<br />
TC-35<br />
Operational<br />
characteristics<br />
TYPE<br />
UL/CSA HP ratimgs<br />
Full voltage-across the line 120V<br />
240V<br />
HP<br />
HP<br />
3 phases<br />
480V<br />
600V<br />
HP<br />
HP<br />
1 phase (2 poles) 115V<br />
230V<br />
HP<br />
HP<br />
DC switching capacity<br />
Rated current Ie for 1 contact<br />
DC21A T=1ms 48V<br />
60V<br />
110V<br />
220V<br />
440V<br />
A<br />
A<br />
A<br />
A<br />
A<br />
DC23A T=15ms (notor cluty) 24V<br />
48V<br />
60V<br />
A<br />
A<br />
A<br />
No. of contacts connected in 110V A<br />
series are indicated in brackets<br />
220V A<br />
DC switching capacity<br />
24V A<br />
Rated current Ie for 1 contact 48V A<br />
DC13A T=50ms 60V<br />
110V<br />
220V<br />
440V<br />
A<br />
A<br />
A<br />
A<br />
Mechanical life<br />
Terminal screw<br />
cycles<br />
M<br />
Maximum tightening torque<br />
Nm<br />
Conductor cross section max. r/f<br />
lbft<br />
2 mm 2<br />
r: rigido<br />
min. r/f<br />
2 AWG<br />
2 mm 2<br />
f: flexible<br />
AMBIENT CONDITIONS<br />
2 AWG<br />
Ambient operating temperature<br />
Ambient storage temperature<br />
°F<br />
°F<br />
GX16 GX20 GX32 GX40 GN12 GN20 GN25 GN32 GN40 GN63 GN125<br />
1.5 1.5 3 5 1.5 1.5 3 5 5 7.5 15<br />
3 3 7.5 10 3 3 5 10 10 15 25<br />
5 5 15 15 – – 10 15 20 25 50<br />
5 5 15 15 – – 10 15 20 25 40<br />
0.75 0.75 1.5 2 0.75 0.75 1.5 2 2 5 7.5<br />
1 1.5 3 5 1 2 3 5 5 10 15<br />
16 20 32 40 12 20 25 32 40 63 125<br />
16 20 32 40 12 20 25 32 40 50 80<br />
4 4 5 6 4 4 4 6 6 8 10<br />
0.5 0.6 0.8 0.8 0.6 0.6 0.7 0.8 - - -<br />
0.25 0.25 0.25 0.25 0.25 0.25 - - - - -<br />
16(1) 20(1) 32(1) 40(1) 10(1) 20(1) 25(1) 32(1) 40(1) 50(1) 125(1)<br />
16(2) 20(2) 32(2) 40(1) 10(2) 20(2) 25(2) 32(2) 40(2) 50(2) 125(2)<br />
16(3) 20(3) 32(3) 40(3) 10(3) 20(3) 25(3) 32(3) 40(3) 50(3) 125(3)<br />
10(3) 10(3) 15(3) 20(3) 5(3) 10(3) 12(3) 15(3) 20(3) 25(3) 50(3)<br />
7(4) 8(4) 12(4) 12(4) 5(4) 8(4) 10(4) 12(4) 12(4) 15(4) 20(4)<br />
16 20 32 40 12 20 25 32 40 63 125<br />
14 16 25 32 10 16 20 25 32 40 100<br />
12 12 16 16 8 12 16 16 16 28 50<br />
0.8 1 3 3 1 1 1.5 3 3 3.3 4<br />
0.3 0.4 0.5 0.5 0.4 0.4 0.4 0.5 - - -<br />
0.15 0.15 0.15 0.15 0.15 0.15 - - - - -<br />
5x10 6 5x10 6 5x10 6 5x10 6 3x10 6 5x10 6 5x10 6 5x10 6 5x10 6 5x10 6 1x10 6<br />
3 3 4 4 3 3 3.5 4 4 5 2 x 5<br />
0.5 0.8 1.2 1.2 0.5 0.5 0.8 1.2 1.2 2 2<br />
0.37 0.59 0.88 0.88 0.37 0.37 0.59 0.88 0.88 1.47 1.47<br />
2.5/2.5 2.5/2.5 10/6 10/6 1.5/1.5 2.5/2.5 6/4 6/4 10/6 16/10 70/50<br />
14/14 14/14 8/10 8/10 16/16 14/14 10/12 10/12 8/10 6/8 2/0 / 1/0<br />
0.5/0.5 0.5/0.5 1.5/1.5 1.5/1.5 0.5/0.5 0.5/0.5 0.5/0.5 1.5/1.5 1.5/1.5 2.5/2.5 2.5/2.5<br />
20/20 20/20 16/16 16/60 20/20 20/20 20/20 16/16 16/16 14/14 14/14<br />
-15 to +130 (-25...+55°C)<br />
-40 to +160 (-40...+70°C)<br />
TC<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com
TC-36<br />
Technical characteristics<br />
Timers<br />
®<br />
electric<br />
TC<br />
Operational<br />
characteristics<br />
TYPE AT1P AT1CP ATD AT1DP<br />
DESCRIPTION<br />
On delay On delay Off delay Off delay, auxiliary<br />
supply<br />
Multiscale Multiscale Multiscale Multiscale<br />
Multivoltage Multivoltage Single voltage Single voltage<br />
CONTROl CIRCUIT<br />
Rated control power 24VAC / 100-240VAC❶ 12-24VAC/DC❶ 24VAC/DC❶ 24VAC/DC❶<br />
24VAC / 220-440VAC❶ 48-60 / 110-125VAC/DC❶ 48VAC/DC❶ 48VAC/DC❶<br />
110-127VAC❶ 110-127VAC❶<br />
220-240VAC❶ 220-240VAC❶<br />
Rated frequency<br />
50-60Hz<br />
Operating voltage range 0.85-1.1 Us 0.85-1.1 Us in AC 0.8-1.1 Us<br />
0.6-1.3 Us in DC<br />
Power consumption (maximum) 24V=1VA; 12-24V=1.5W 2.7VA AC 8.7VA AC<br />
100-240V=10VA 48-60/110-125V=2.5W 0.3W DC 1.6W DC<br />
(110V=1.4VA)<br />
220-440V=15.6VA<br />
(220V=3.2VA)<br />
TIMING CIRCUIT<br />
Time setting range Multiscale Multiscale Multiscale Multiscale<br />
0.3-3s 0.3-3s 0.3-3s 0.3-3s<br />
1.2-12s 1.2-12s 1.2-12s 1.2-12s<br />
9.6-96s 9.6-96s 9.6-96s 9.6-96s<br />
76.8-768s 76.8-768s 76.8-768s 76.8-768s<br />
NOTE:<br />
del. = delayed<br />
inst. = instantaneous<br />
DT = Double-Throw<br />
❶ Other voltages on request; contact Sales &<br />
Technical Support for details.<br />
Setting accuracy ±9%<br />
Repeat accuracy ≤ ±0.5%<br />
Influence of voltage variation ±0.3% –0.3% ±0.3%<br />
+0.74%<br />
Average variation of set delays<br />
related to +70°F/20°C at -5°F/–20°C +2%<br />
condition<br />
at +140°F+60°C –3%<br />
Minimum ON time –– 25ms<br />
Resetting during operation ≥ 80ms ≥ 60ms 200ms ≥ 55ms<br />
time elasped time ≥ 55ms ≥ 50ms –– ≥ 80ms<br />
Immunity time for microbreakings ≤ 30ms ≤ 30ms ≤ 7ms ≤ 7ms<br />
OUTPUT CONTACTS<br />
Contact arrangement<br />
1 delayed double-throw<br />
Maximum switching voltage 440VAC (rated 250V) 250VAC 250VAC<br />
Conventional free air<br />
8A<br />
thermal current Ith<br />
UL designation (IEC/EN 60947-5-1)<br />
B300 (AC1 8A 250VAC)<br />
<strong>Electric</strong>al life (with rated load)<br />
10 5 cycles<br />
Mechanical life<br />
30x10 6 cycles<br />
Tightening torque (maximum)<br />
9lbin / 1.2Nm<br />
Conductor section (min-max) 2x18 - 14 AWG (except combination 18-14) 1.5-5mm 2<br />
INSULATION (input-output)<br />
Rated insulation voltage<br />
250V<br />
Rated impulse withstand voltage<br />
4kV<br />
Power frequency withstand voltage 2.5kV (50Hz - 60s)<br />
AMBIENT CONDITIONS<br />
Operating temperature<br />
+15...+140°F (–10...+60°C)<br />
Storage temperature<br />
-20...+175°F (–30...+80°C)<br />
Housing<br />
Self-extinguishing polyamide<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com
®<br />
electric<br />
Technical characteristics<br />
Timers<br />
TC-37<br />
BTPM1 BTPM DRPL BT2N L48TP L48TPB L48M<br />
Programmable Programmable Asymmetrical For starting On delay On delay Programmable<br />
multifunction multifunction recycle multifunction<br />
Multiscale Single scale Multiscale Multiscale Multiscale<br />
Multivoltage Dual voltage Multivoltage Single voltage Multivoltage<br />
TC<br />
24VAC/DC❶ 24/48VAC/DC❶ 24VAC/DC❶ 24VAC/DC❶ 24-240VAC/DC❶<br />
110-127VAC❶ 24VAC/DC 110VAC❶ 110VAC❶<br />
220-240VAC❶ 110-127VAC❶ 220-240VAC❶ 220-240VAC❶<br />
50-60Hz<br />
24VAC/DC<br />
220-240VAC❶<br />
24VAC/DC<br />
380-415VAC❶<br />
24VAC/DC<br />
415-440VAC❶<br />
50/60Hz<br />
0.8-1.1 Us 0.85-1.1 Us<br />
9.2VA AC 12.8VA AC 8.7VA AC 6VA<br />
2.9W DC 1W DC 1.5W DC<br />
Multiscale Multiscale Single scale Multiscale Multiscale Multiscale<br />
0.3-3s 0.3-3s/min start time: 0.3-3s 0.05-1s 0.05-1s<br />
1.2-12s 0.6-6s/min 0.6-6s 0.12-12s 0.10-10s 0.1-10s<br />
9.6-96s 1.2-12s/min 1.2-12s 10-100s 0.6s-1min 0.6s-1min<br />
76.8-768s 3-30s/min 3-30s 78-780s 6s-10min 6s-10min<br />
0.3-3min 6-60s/min 6-60s 18s-3min 0.05-1min<br />
1.2-12min 12-120s/min 72s-12min 0.1-10min<br />
9.6-96min Transition time: 10-100min 0.6min-1h<br />
76.8-768min 20-300ms 78-780min 1min-10h<br />
±9% ±5%<br />
≤±0.5% ±0.5%<br />
±0.3% ±0.5%<br />
+2% +2%<br />
–3% –3%<br />
–– ––<br />
≥75ms ≥ 75ms ≥ 85ms ≥75ms ≥ 0.1s ≥ 0.1m ≥ 0.1s<br />
≥ 45ms ≥ 45ms ≥ 75ms ≥ 70ms ≥ 65ms ≥ 65ms ≥ 65ms<br />
≤ 7ms ≤ 7ms ≤ 7ms ≤ 7ms ≤ 40ms ≤ 40ms ≤ 40ms<br />
1 delayed DT 2 del or 1 inst + 1 del DT 2 delayed DT 2 delayed DT 1 delayed DT 2 del or 1 inst + 1 del DT 2 delayed DT<br />
250VAC 380VAC 250V<br />
8A<br />
5A<br />
B300 (AC1 8A 250VAC)<br />
10 5 cycles<br />
30x10 6 cycles<br />
9 lbin / 1.2Nm ––<br />
2 18-14 AWG (except combination 18-14) / 1.5-5mm 2 ––<br />
250V 500V 250V<br />
4kV ––<br />
2.5kV (50Hz - 60s) 2kV (50Hz - 60s)<br />
+14...+140°F (-10...+60°C)<br />
-20...+175°F (-30...+80°C)<br />
Self-extinguishing polyamide<br />
+14...+140°F (-10...+60°C)<br />
-20...+175°F (-30...+80°C)<br />
Self-extinguishing polyamide<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com
TC-38<br />
Technical characteristics<br />
Timers<br />
®<br />
electric<br />
TC<br />
TYPE TM P TM M1 TM M2 TM PL TM D TM ST TM LS<br />
DESCRIPTION<br />
On delay Programmable Programmable Asymmetrical True off For starting Staircase<br />
multifunction multifunction timing recycle delay illumination<br />
Multiscale Multiscale Multiscale Multiscale Multiscale Multiscale Single scale<br />
Multivoltage Multivoltage Multivoltage Multivoltage Multivoltage Multivoltage Single voltage<br />
CONTROL CIRCUIT<br />
Rated control 24-48VDC 12-240VAC/DC 24-240VAC/DC 24-48VDC 220-240VAC<br />
power Us 24-240VAC 24-240VAC<br />
380-440VAC<br />
Rated frequecy<br />
50/60Hz<br />
Operating voltage range<br />
0.85-1.1 Us<br />
Power consumption/dissipation 1.2VA/0.8W (24-48VDC) 0.6VA/0.3W (12-48VDC) 1.1VA/0.8W (12-48VDC) 0.15VA/0.15W (12-48VDC) 0.1VA/0.1W (24-48V) 1.2VA/0.8W (24-48VDC) 12VA /0,8W (energized)<br />
(maximum)<br />
16VA/0.9W (110-240VAC) 1.6VA/1.2W (110-240VAC) 1.8VA/1.2W (110-240VAC) 0.9VA/0.8W (110-240VAC) 1.1VA/0.8W (110-240VAC) 16VA/0.9W (110-240VAC) 5VA/0.5W (de-energized)<br />
TIMING CIRCUIT<br />
Time setting range Multiscale Multiscale Multiscale Multiscale Multiscale Multiscale Multiscale<br />
0.1-1s 0.1-1s 0.1-1s 0.1-1s 0.06-0.6s 0.1-1s 0.5-20min<br />
1-10s 1-10s 1-10s 1-10s 0.6-6s 1-10s<br />
6s-1min 6s-1min 6s-1min 6s-1min 6s-1min 6s-1min<br />
1-10min 1-10min 1-10min 1-10min 12s-2min 1-10min<br />
6min-1h 6min-1h 6min-1h 6min-1h<br />
1-10h 1-10h 1h-10h 1h-10h<br />
0.1-1day 0.1-1day 0.1-1day 0.1-1day<br />
1-10days 1-10days 1-10days 1-10days<br />
ON only ON only ON only 3-30days<br />
OFF only OFF only OFF only 10-100days<br />
Setting accuracy
®<br />
electric<br />
Technical characteristics<br />
Protection relays<br />
TC-39<br />
TYPE PMA20 PMA21 PMA30 PMA40 PMA50 PMF20<br />
DESCRIPTION<br />
Single-phase Single-phase Single-phase Phase shift control Phase shift control Frequency<br />
minimum current maximum current minimum or maximum for pump dry for miminum and monitoring<br />
monitoring monitoring current monitoring running maximum<br />
AC/DC multiscale AC/DC multiscale AC/DC multiscale (minimum cosϕ) cosϕ<br />
CONTROL CIRCUIT<br />
Rated valve to be monitored Ie 0.02 - 1 - 5 - 16A Ie 16A Ie 16A 40-70Hz<br />
Rated frequency<br />
50/60 Hz<br />
Overload capacity<br />
❹<br />
Connection Direct or by current tramsformer Direct<br />
Adjustment Tripping value 5-100% full scale of current 0...1 cosϕ 0...1 cosϕ 101-110% for max Hz<br />
90-99% for min Hz<br />
Tripping time 0.1-20s 0.1-20ms 0.1-20ms 0.1-20s<br />
Inhibition time 0.1-20s 0.1-20s 0.1-20s ––<br />
Resetting hysteresis 5-30% –– 5-30% 0.5%<br />
Resetting Automatic Automatic<br />
Manual using external N/C contact<br />
Repeat accuracy 1% ±1.5% ±1.5% ––<br />
AUXILIARY SUPPLY<br />
Auxiliary supply voltage Us 24-240VAC/DC 220-240VAC 220-240VAC 220-240VAC<br />
380-415VAC 380-415VAC 380-415VAC<br />
Operating voltage range 0.85-1.1 Us 0.80-1.1 Us 0.8-1.1 Us 0.85-1.1 Us<br />
Rated frequency<br />
50/60Hz<br />
Power consumption (maximum) ❶ 4VA 3.5VA 3.5VA ––<br />
Power dissipation (maximum) 1.2W 1.8W 1.8W 1.5W<br />
RELAY OUTPUTS<br />
Number of relays 1<br />
Relay state<br />
Normally de-energized;<br />
energizes at tripping<br />
Contact arrangement<br />
1 double-throw<br />
Rated operational voltage<br />
250VAC<br />
Maximum switching voltage<br />
400VAC<br />
Conventional free air thermal current Ith<br />
8A<br />
UL (IEC/EN 60947-5-1) designation<br />
B300 (AC1 8A 250VAC)<br />
<strong>Electric</strong>al life (with rated load)<br />
10 5 cycles<br />
Mechanical life<br />
30x10 6 cycles<br />
Indications<br />
❹<br />
CONNECTIONS<br />
Tightening torque (maximum)<br />
7lbin / 0.8Nm<br />
Conductor section (min-max) 24-12 AWG / 0.2-4.0mm 2<br />
INSULATION (input-output)<br />
Rated insulation voltage<br />
575V<br />
Rated impulse withstand voltage<br />
6kV<br />
Power frequency withstand voltage 4kV (50Hz - 60s)<br />
AMBIENT CONDITIONS<br />
Operating temperature<br />
-5...+140°F (-20...+60°C)<br />
Storage temperature<br />
-20...+175°F (-30...+80°C)<br />
Housing<br />
Self-extinguishing polyamide<br />
TC<br />
❶ Value referred to 110VAC<br />
❹ Contact Sales & Technical Support.<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com
TC-40<br />
Technical characteristics<br />
Protection relays<br />
®<br />
electric<br />
TC<br />
TYPE Single phase PMV55 — — — — — — —<br />
Three phase — PMV10 PMV20 PMV30 PMV40 PMV50 PMV60 PMV70<br />
DESCRIPTION<br />
Minimum and Phase sequence Phase sequence Phase sequence, Phase sequence, Phase sequence, Phase sequence, Phase sequence,<br />
maximum voltage and phase loss and phase loss phase loss and phase loss and phase loss, voltage phase loss, voltage phase loss, voltage<br />
voltage too low asymmetry too high and too low and too high and too<br />
too high too low asymmetry low and asymmetry<br />
too high too high<br />
CONTROL CIRCUIT<br />
Rated voltage to be 208V-240VAC 208-440VAC 100-240VAC 208V-240VAC<br />
monitored Ue 380V-440VAC 208-575VAC 380V-575VAC<br />
380-600VAC<br />
600VAC<br />
Maximum voltage set-point 105-115% Ue –– — — — 105-115% Ue — 105-115% Ue<br />
Minimum voltage set-point 80-95% Ue –– — 80-95% Ue — 80-95% Ue 80-95% Ue 80-95% Ue<br />
Asymmetry set-point — –– — — 5-15%Ue 5-15%Ue — —<br />
Tripping delay time 0.1-20s 60ms 60ms 0.1-20s 60ms for phase loss only<br />
Resetting time 0.1-20s 0.5s 0.5s 0.1-20s 0.5s<br />
0.5s at power up 0.5s at power up<br />
Resetting hysteresis 3% 5% 5% 3%<br />
Instantaneous tripping for Ue
®<br />
electric<br />
Technical characteristics<br />
Liquid level control relays<br />
TC-41<br />
TYPE LVM20 LVM25 LVM30 LVM40 LVMP05 LVMP10<br />
DESCRIPTON<br />
Modular<br />
Automatic resetting –– ––<br />
Single voltage Dual voltage Dual voltage Single voltage Dual voltage Single voltage<br />
Application (examples) Empting function Emptying or filling Emptying or filling Multiple functions Starting control Starting control<br />
functions functions of 2 motors of 2 motors<br />
Operating principle<br />
<strong>Electric</strong>al conductivity of liquids<br />
POWER SUPPLY<br />
Supply voltage Ue 24VAC 24-48VAC/DC 24VAC/ 24VAC 24-48VDC 24VAC<br />
110-127VAC 110-240VAC/DC 220-240VAC 110-127VAC 24-240VAC 220-240VAC<br />
220-240VAC 110-127/ 220-240VAC 380-415VAC<br />
380-415VAC 380-415VAC 380-415VAC<br />
Operating voltage range 0.85-1.1 Ue 50/60Hz ±5%<br />
Power consumption (maximum) 3.5VA 4VA 5.5VA 4.5VA 1.6VA 4.8VA<br />
Power dissipation (maximum) 1.8W 1.2W 2.8W 2.8W 0.9W 3W<br />
OUTPUTS<br />
Number of connectable electrodes 3 3 3 5 –– ––<br />
Type of electrode<br />
Electrodes: SN1 / SCM / CGL / PS31 / PS35 or similar<br />
Electrode voltage 7.5VAC 5Vpp 7.5VAC 5Vpp –– ––<br />
Sensitivity 2.5-50kohm 2.5-100kohm 2.5-50kohm 2.5-200kohm –– ––<br />
TIME DELAYS<br />
Tripping time (minimum) ≤600ms ≤1s ≤1s 1s –– ––<br />
Resetting time (minimum) ≤750ms ≤1s ≤1s 1s –– ––<br />
Probe tripping delay –– –– OFF-10s 1-10s –– ––<br />
Relay energising delay –– –– OFF-300s 0-30min 10ms 20ms<br />
RELAY OUTPUTS<br />
Number of relays 1 relay with SPDT 1 relay with SPDT 1 relay with DPDT 2 relays; one with SPDT 2 relays; each 2 relays; each<br />
and one with 1 N/O contact with 1N/O contact with 1N/O contact<br />
Rated utilization voltage<br />
250VAC<br />
Conventional free air thermal<br />
8A<br />
current Ith<br />
UL (IEC/EN 60947-5-1)<br />
B300 (AC1 8A 250VAC)<br />
designation<br />
Maximum switching voltage<br />
400VAC<br />
<strong>Electric</strong>al life (with rated load)<br />
10 5 cycles<br />
Mechanical life<br />
30x10 6 cycles<br />
Indications<br />
Green LED for power on Green LED for power on Green LED for power on Green LED for power on Green LED for power on Green LED for power on<br />
Red LED for relay state Red LED for relay state Red LED for relay state 2 red LEDs for relay state Red LED for relay state Red LED for relay state<br />
2 red LEDs for probe state<br />
CONNECTIONS<br />
Tightening torque (maximum)<br />
7lbin / 0.8Nm<br />
Conductor section (min-max) 24/12 AWG / 0.2-4mm 2<br />
INSULATION<br />
Rated impulse wihstand 6kV 4kV 6kV 6kV 4kV 4kV<br />
voltage Uimp<br />
Power frequency withstand 4kV 2kV 4kV 4kV 2kV 2.5kV<br />
voltage<br />
Rated insulation voltage Ui 415VAC 240VAC 415VAC 415VAC 250VAC 400VAC<br />
Double insulation ≤250VAC ≤250VAC ≤250VAC ≤250VAC –– ––<br />
Supply/relay/electrode<br />
AMBIENT CONDITIONS<br />
Operating temperature<br />
-5...+140°F (-20...+60°C)<br />
Storage temperature<br />
-20...+175°F (-30...+80°C)<br />
HOUSING<br />
Housing material<br />
Self-extinguishing polyamide<br />
Typical configuration LVM20 + n° 3 SN1 electrodes LVM25 + n° 3 SN1 electrodes<br />
(examples) LVM30 + n° 3 SN1 electrodes LVM40 + n° 5 SN1 electrodes<br />
Maximum cable length<br />
Contact Sales & Technical Support for details<br />
NOTE:<br />
SPDT = Single-pole double-throw<br />
DPDT = Double-pole double-throw<br />
N/O = normally open<br />
TC<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com
TC-42<br />
Technical characteristics<br />
Digital metering instruments<br />
®<br />
electric<br />
TC<br />
Operational<br />
characteristics<br />
❶ Other voltages on request. Contact Sales &<br />
Technical Support for details.<br />
❷ ±0.5% f.s. ±digit only for DMK71 R1.<br />
❸ 25-660VAC for DMK84 R1.<br />
TYPE WITHOUT OUTPUT DMK70 - DMK10 DMK71 - DMK11 DMK75 - DMK15 - DMK16<br />
TYPE WITH OUTPUT DMK70 R1 - DMK10 R1 DMK71 R1 - DMK11 R1 DMK75 R1 - DMK15 R1<br />
TYPE OF CONTROL<br />
Three phase with or without neutral<br />
TYPE OF INSTRUMENT Voltmeter Ammeter Combined voltmeterammeter-wattmeter<br />
(multimeter - DMK16)<br />
AUXILIARY SUPPLY<br />
Rated control power Us<br />
110-127VAC ❶<br />
Operating voltage range 0.85-1.1 Us 50-60Hz ±10%<br />
Power consumption (maximum) 3.2VA 3.2VA 3.2VA DMK75<br />
(3.5VA for DMK... R1) (3.5VA for DMK... R1) (3.5VA for DMK... R1)<br />
Power dissipation (maximum) 1.5W 1.5W 1.5W DMK75<br />
(1.8W for DMK... R1) (1.8W for DMK... R1) (1.8W for DMK... R1)<br />
VOLTAGE INPUTS<br />
Maximum rated voltage 600VAC phase-phase - 600VAC phase-phase<br />
347VAC phase-neutral - 347VAC phase-neutral<br />
Operating voltage range 15-660VAC phase-phase - 35-660VAC phase-phase<br />
10-382VAC phase-neutral - 20-382VAC phase-neutral<br />
Frequency range 50-60Hz ±10% - 50-60Hz ±10%<br />
Method of measuring True RMS value - True RMS value<br />
Measuring input impedance >1.1Mohm phase-phase - >1.1Mohm phase-phase<br />
>0.55Mohm phase-neutral - >0.55Mohm phase-neutral<br />
Acquisition time 80ms DMK...R1 only - 80ms DMK...R1 only<br />
CURRENT INPUTS<br />
Rated current Ie - 5A -<br />
Measuring range - 0.05-5.75A -<br />
Type of input - Shunt -<br />
Type of measuring - True RMS value -<br />
Overload capacity - +20% Ie -<br />
Overload peak - 50A for 1 second -<br />
Dynamic limit - 125A for 10ms -<br />
Power consumption -
®<br />
electric<br />
Technical characteristics<br />
Digital metering instruments<br />
TC-43<br />
DMK80- DMK00 DMK81 - DMK01 DMK82 - DMK02 DMK83 - DMK03 DMK84 - DMK04<br />
DMK80 R1 - DMK00 R1 DMK81 R1 - DMK01 R1 - DMK83 R1 - DMK03 R1 DMK84 R1 - DMK04 R1<br />
Single phase<br />
Voltmeter Ammeter Voltmeter or Frequency meter Cosphi meter<br />
ammeter<br />
TC<br />
110-127VAC ❶<br />
0.85-1.1 Us 50-60Hz ±10%<br />
3.2VA 3.2VA 3.2VA 3.2VA 3.2VA<br />
(3.5VA for DMK... R1) (3.5VA for DMK... R1) (3.5VA for DMK... R1) (3.5VA for DMK... R1)<br />
1.5W DMK80 1.5W DMK81 1.5W 1.5W DMK83 1.5W DMK84<br />
(1.8W for DMK... R1) (1.8W for DMK... R1) - (1.8W for DMK... R1) (1.8W for DMK... R1)<br />
600VAC - 600VAC - 600VAC<br />
- - -<br />
15-660VAC - 15-660VAC - 25-660VAC ❸<br />
- - -<br />
50-60Hz ±10% - 50-60Hz ±10% - 50-60Hz ±10%<br />
True RMS value - True RMS value - True RMS value<br />
>1.1Mohm - >1.1Mohm - >1.1Mohm<br />
- - -<br />
25ms DMK::: R1 only - - 25ms DMK... R1 only 60ms DMK... R1 only<br />
- 5A 5A - 5A<br />
- 0.05-5.75A 0.05-5.75A - 0.05-5.75A<br />
- Shunt Shunt - Shunt<br />
- True RMS value True RMS value - -<br />
- +20% Ie +20% Ie - +20% Ie<br />
- 50A for 1 second 50A for 1 second - 50A for 1 second<br />
- 125A for 10ms 125A for 10ms - 125A for 10ms<br />
-
TC-44<br />
Technical characteristics<br />
Digital metering instruments<br />
®<br />
electric<br />
TC<br />
Operational<br />
characteristics<br />
TYPE DMK 20 - DMK 21 - DMK 22 DMK 25 - DMK 26<br />
AUXILIARY SUPPLY<br />
Rated control power Us 208-240VAC 12-24VDC from battery<br />
Operating voltage range 154-288VAC for DMK 20 9-32VDC<br />
177-264VAC for DMK 21 - DMK 22<br />
Frequency 45-65Hz —<br />
Power consumption 5.5VA (Us=240V) for DMK 20 1.1W maximum<br />
4.5VA (Us=240) for DMK 21 - DMK 22<br />
Power dissipation 2.5W (Us=240V) for DMK 20 1.1W maximum<br />
2.6W (Us=240) for DMK 21 - DMK 22<br />
Immunity tme of microbreakings 20ms 500ms<br />
VOLTAGE INPUTS<br />
Maximum rated voltage<br />
690VAC L-L<br />
(400VAC L-N)<br />
Operating voltage range<br />
60-830V L-L<br />
(30-480VAC L-N)<br />
Frequency range<br />
45-65Hz<br />
Method of measuring<br />
True RMS value<br />
Measuring input impedance<br />
>1.1MΩ L-L and >570kΩ L-N<br />
Method of connection<br />
Single phase, three-phase<br />
or balanced three-phase system<br />
Measuring error<br />
Class 0.5 ±0.25% full scale ±1digit<br />
CURRENT INPUTS<br />
Rated currrent Ie<br />
standard 5A (1A on request)<br />
Measuring range<br />
0.05-6A<br />
Method of measuring<br />
True RMS value<br />
Overload capacity<br />
+20% Ie via external CT with 5A secondary<br />
Overload peak<br />
50A for 1 second<br />
Dymanic peak<br />
125A for 10ms<br />
Power consumption<br />
®<br />
electric<br />
Technical characteristics<br />
Digital metering instruments<br />
TC-45<br />
DMK 30 - DMK 31 - DMK 32 DMK 40 DMK 50 - DMK 51 - DMK 52 DMK 60 - DMK 61 - DMK 62<br />
100-240VAC/110-250VDC 100-240VAC/110-250VDC 208-240VAC 100-240VAC/110-250VDC<br />
85-265VAC/93.5-300VDC 85-265VAC/93.5-300VDC 154-288VAC for DMK 50 85-265VAC/93.5-300VDC<br />
177-264VAC for DMK 51 - DMK 52<br />
45-450Hz 45-450Hz 45-65Hz 45-450Hz<br />
10VA/4W 10VA/4W 5.5VA (Us=240V) for DMK 50 - DMK 51 10VA/4W<br />
6VA (Us=240) for DMK 52<br />
3W (DMK 30) 4W 2.5W (Us=240V) for DMK 50 - DMK 51 3W for DMK 60<br />
4W (DMK 31 - DMK 32) 2.8W (Us=240) for DMK 52 4W for DMK 61 - DMK 62<br />
20ms 20ms 20ms 20ms<br />
TC<br />
690VAC L-L<br />
(400VAC L-N)<br />
20-830V L-L 20-830V L-L 60-830V L-L 20-830V L-L<br />
(10-480VAC L-N) (10-480VAC L-N) (30-480VAC L-N) (10-480VAC L-N)<br />
45-65Hz<br />
True RMS value<br />
>1.1MΩ L-L and >570kΩ L-N<br />
Single-phase or three-phase Single-phase or three-phase Single-phase, three-phase Single-phase or three-phase<br />
system with or without neutral system with or without neutral or balanced three-phase system system with or without neutral<br />
Class 0.5 ±0.25% full scale ±1digit<br />
5A (1A on request)<br />
0.02-6A 0.02-6A 0.05-6A 0.02-6A<br />
True RMS value<br />
+20% Ie via external CT with 5A secondary<br />
50A for 1 second<br />
125A for 10ms<br />
TC-46<br />
Technical characteristics<br />
Automatic power factor controllers<br />
®<br />
electric<br />
TC<br />
Operational<br />
characteristics<br />
TYPE DCRK5 - DCRK7 DCRK8 - DCRK12 DCRJ8 - DCRJ12 DCRJ12F<br />
AUXILIARY SUPPLY CIRCUIT<br />
Control power ❶ ❶ 110-127 / 110-127 /<br />
220-240VAC ❷ 220-240VAC ❷<br />
(dual voltage) (dual voltage)<br />
Operational limit –– –– -15 to +10% -15 to +10%<br />
Operating frequency –– –– 50Hz or 60Hz ±5% 50Hz or 60Hz ±5%<br />
Power consumption (maximum) –– –– 9.7VA 9.2VA<br />
Maximum dissipation –– –– 5.5W 5.5W<br />
(output contacts excluded)<br />
VOLTAGE CIRCUIT<br />
Control voltage 440-480VAC ❷ (powered by monitored voltage) 100-690VAC<br />
Operational limit -15 to +10% -15 to +10% 85 to +760VAC 85 to +760VAC<br />
Operating frequency 50 or 60Hz ±1% (self configurable) 50 or 60Hz ±5% (self configurable)<br />
Power consumption 6.2VA 5VA 0.03VA 0.03VA<br />
Maximum dissipation 2.7W 3W –– ––<br />
(output contacts excluded)<br />
Maximum dissipation of each 0.5W 0.5W 0.5W 0.5W<br />
output contact (5A 250VAC load)<br />
Immunity time for microbreaking ≤65ms ≤65ms ≤45ms ≤45ms<br />
No-voltage release ≥8ms ≥8ms ≥8ms ≥8ms<br />
CURRENT CIRCUIT<br />
Rated current Ie 5A (1A on request) 5A (1A on request) 5A (1A on request) 5A (1A on request)<br />
Operating limit 0.125-6A 0.125-6A 0.125-6A 0.125-6A<br />
Constant overload 1.2 Ie 1.2 Ie 1.2 Ie 1.2 Ie<br />
Short time withstand current 10 Ie for 1s 10 Ie for 1s 10 Ie for 1s 10 Ie for 1s<br />
Power consumption 0.65W 0.65W 0.27VA 0.27VA<br />
DETECTION DATA<br />
Type of voltage and current detection RMS RMS RMS RMS<br />
Power factor adjustment 0.8 ind.-0,8 cap. 0.8 ind.-0.8 cap. 0.8 ind.-0.8 cap. 0.8 ind.-0.8 cap.<br />
Type of temperature sensor Semiconductor (internal) NTC01 (external)<br />
Temperature measurement ranhe -20...+185°F (-30...+85°C) -40...+185°F (-40...+85°C) external<br />
RELAY OUTPUTS<br />
Number of outputs 5 or 7 8 or 12 8 or 12 1<br />
Contact arrangement 1 each w/1 NO contact 7 or 11 contacts each with 1 NO + 1 SPDT 1 SPDT<br />
Rated capacity Ith 5A - 250V (AC1) 5A - 250V (AC1) 5A - 250V (AC1) 5A - 250V (AC1)<br />
Maximum capacity of 12A 12A 12A 12A<br />
contact common<br />
Maximum switching voltage 440VAC 440VAC 440VAC 440VAC<br />
UL (IEC/EN 60947-5-1) C250, B400 C250, B400 C250, B400 C250, B400<br />
designation (AC, DC)<br />
<strong>Electric</strong>al life 10 5 cycles 10 5 cycles 10 5 cycles 10 5 cycles<br />
(at rated load)<br />
Mechanical life 30x10 6 30x10 6 30x10 6 30x10 6<br />
STATIC OUTPUTS<br />
Number of outputs –– –– –– 11<br />
Type of output –– –– –– Opto-isolated bidirectional<br />
(Opto-Mosfet)<br />
Rated operational voltage –– –– –– 40VDC - 30VAC<br />
Rated operational current –– –– –– 55mA at 60°C<br />
CONNECTIONS<br />
Type of termination Removable/plug-in Removable/plug-in Removable/plug-in Removable/plug-in<br />
Conductor cross section (min-max) 24/12 AWG / 0.2-2.5mm 2<br />
AMBIENT CONDITIONS<br />
Operating tempareture<br />
-5...-140°F (-20...+60°C)<br />
Storage temperature<br />
-20...+175°F (-30...+80°C)<br />
HOUSING<br />
Material Self-extinguishing thermoplastic Noryl Self-extinguishing thermoplastic LEXAN<br />
Version Flush mount 96x96mm Flush mount 144x144mm Flush mount 144x144mm Flush mount 144x144mm<br />
❶ Refer to data given under voltage circuit below.<br />
❷ Other voltages available on request.<br />
SPDT = Single-pole double throw.<br />
96x96mm = 3.78x3.78in; 144x144mm = 5.67x5.67in<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com
®<br />
electric<br />
Technical characteristics<br />
Automatic transfer switch controllers<br />
TC-47<br />
Operational<br />
characteristics<br />
TYPE ATL20 ATL30<br />
AUXILIARY SUPPLY<br />
Rated voltage<br />
12-24-48VDC; 110-120VAC<br />
Operating voltage range<br />
9-70VDC; 93.5-132VAC<br />
Rated insulation voltage Ui<br />
690V<br />
Frequency<br />
45-65Hz<br />
Power consumption (maximum)<br />
9VA (120VAC)<br />
Power dissipation (maximum)<br />
4.1W (48VDC); 6.3W (120VAC)<br />
Current consumption (maximum)<br />
300mA at 12VDC; 180mA at 24VDC; 90mA at 48VDC<br />
Immunity time for microbreakings<br />
50ms<br />
VOLTAGE INPUTS<br />
Maximum rated voltage<br />
690VAC L-L (400VAC L-N); UL rated 600VAC L-L (340VAC L-N)<br />
Measure range<br />
80-800VAC L-L<br />
Frequency range<br />
45-65Hz<br />
Method of measuring<br />
True RMS value<br />
Measuring input impedance<br />
>1.1MΩ L-L and >0.5MΩ L-N<br />
Method of connection<br />
Single-phase or three-phase system<br />
Measuring error<br />
Class 0.5 ±0.25% full scale ±1 digit<br />
CURRENT INPUTS<br />
Type of input<br />
Negative<br />
Input current<br />
≤10mA<br />
Input signal - “0” logic state<br />
≤1.5V (2.9V typical)<br />
Input signal - “1” logic state<br />
≥5.3V (4.3V typical)<br />
Input signal delay<br />
≥50ms<br />
RELAY OUTPUTS<br />
Number of outputs 7<br />
Contact configuration<br />
– 2 relays, each with 1 N/O contact - B300 (16A - 250VAC AC1)<br />
– 3 relays, each with 1 N/O contact - B300 (5A - 250VAC AC1)<br />
(30VDC 1A pilot duty)<br />
– 2 relays, each with 1 SPDT - B300 (8A - 250VAC AC1)<br />
(30VDC 1A pilot duty)<br />
REAL TME CLOCK (ATL30 only)<br />
Energy storage<br />
Back-up capacitors<br />
Operating time without power supply<br />
12-15 days<br />
COMMUNICATION LINES<br />
Serial interface<br />
RS232 with programmable baud rate 1200-38400bps<br />
connection by RJ6/6 jack<br />
–– RS485 opto-isolated with<br />
programmable baud rate 1200-38400 bps<br />
Connection by removable/plug-in<br />
terminals<br />
CONNECTIONS<br />
Type of terminals<br />
Removable / Plug-in<br />
Conduction section (min-max) 24/12 AWG / 0.2-2.5mm 2<br />
Tightening torque (maximum)<br />
4.5lbin / 0.5Nm<br />
AMBIENT CONDITIONS<br />
Operating temperature<br />
-5...+140°F (-20...+60°C)<br />
Storage temperature<br />
-20...+175°F (-30...+80°C)<br />
Relative humidity
TC-48<br />
Technical characteristics<br />
Programmable logic relays<br />
®<br />
electric<br />
TC<br />
Operational<br />
characteristics<br />
TYPE LRD...D024 LRD...A024 LRD...A240<br />
CONTROL POWER SUPPLY<br />
Rated utilization voltage Ue (Frequency range) 24VDC 24VAC 110-240VAC (47-63Hz)<br />
Operating limits 21.6-26.4VDC –– 85-264VAC<br />
DIGITAL INPUTS<br />
Rated voltage 24VDC 24VAC 110-220VAC<br />
Input voltage State 0
<strong>Electric</strong>al<br />
controls for<br />
industrial<br />
automation<br />
Complete the form<br />
and return to the<br />
the local office in<br />
your country:<br />
In the U.S.A.<br />
Fax (757) 575-2900<br />
Email: sales@LovatoUsa.com<br />
www.LovatoUsa.com<br />
In Canada<br />
Fax (450) 681-9884<br />
Email: info@Lovato.ca<br />
www.Lovato.ca<br />
12<br />
11 1<br />
10<br />
2<br />
D A<br />
9 3<br />
C B<br />
8<br />
4<br />
7 5<br />
6<br />
Plate<br />
pos.<br />
indication<br />
1 4 5 8 9 12 13 16 17 20 21 24 25 28 29 32 33 36 37 40 41 44 45 48<br />
2 3 6 7 10 11 14 15 18 19 22 23 26 27 30 31 34 35 38 39 42 43 46 47<br />
C<br />
7<br />
8<br />
9<br />
D<br />
10<br />
11<br />
12<br />
A<br />
1<br />
2<br />
3<br />
B<br />
4<br />
5<br />
6<br />
Front plate 1<br />
X<br />
X<br />
X<br />
X<br />
2<br />
X<br />
X<br />
X<br />
Overlapping Closed contact Open/ Closed Spring<br />
contacts in 2 or more passing contact return<br />
positions contact<br />
Body shape: ■ Square - GX ❶ ■ Round - GN _____________ Amp rating<br />
Version: ■ Front mount ■ Rear mount ■ Enclosed ■ Other __________________<br />
Finish: ■ Standard ❷ ■ Red/yellow padlockable ■ Special ________________<br />
Fixing: ■ 2 screw ■ 4 screw<br />
Qty: ________ Company name and contact details: ________________________________________________________<br />
_____________________________________________________________________________________<br />
❶ Maximum 40A ratings for GX series.<br />
❷ Standard finish is grey front plate, 0-12 indication and a blacke handle; any other is considered special.<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com
®<br />
electric<br />
Notes<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com
®<br />
electric<br />
Notes<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com
®<br />
electric<br />
Index in alphanumeric order<br />
I-I<br />
A014 9-16<br />
9-17<br />
A0191 9-17<br />
A0192 9-17<br />
A114 9-16<br />
9-17<br />
A119U 9-17<br />
A119O 9-17<br />
A124 9-16<br />
9-17<br />
A1691 9-17<br />
A1692 9-17<br />
A1693 9-17<br />
A180 9-17<br />
A181 9-17<br />
A20746 8-20<br />
A20747 8-20<br />
A20748 8-20<br />
A441 9-17<br />
A442 9-17<br />
A443 9-17<br />
ADXM 14-2<br />
14-3<br />
APRBP 9-16<br />
9-17<br />
AR114 9-16<br />
9-17<br />
AR124 9-16<br />
9-17<br />
AR214 9-16<br />
9-17<br />
AR224 9-16<br />
9-17<br />
ASTA 12-3<br />
AT!CP 10-4<br />
AT1DP 10-5<br />
AT1CP 10-4<br />
AT1P 10-4<br />
ATD 10-5<br />
ATL 16-2<br />
16-3<br />
B115 00 3-4<br />
3-5<br />
B115 4 3-6<br />
3-7<br />
B1250 3-4<br />
B1250 4 3-6<br />
B145 00 3-4<br />
3-5<br />
B145 4 3-6<br />
3-7<br />
B1600 3-4<br />
B1600 4 3-6<br />
B180 00 3-4<br />
3-5<br />
B180 4 3-6<br />
3-7<br />
B250 00 3-4<br />
3-5<br />
B250 4 3-6<br />
3-7<br />
B310 00 3-4<br />
3-5<br />
B310 4 3-6<br />
3-7<br />
B400 00 3-4<br />
3-5<br />
B400 4 3-6<br />
3-7<br />
B500 00 3-4<br />
3-5<br />
B500 4 3-6<br />
3-7<br />
B630 00 3-4<br />
3-5<br />
B630 1000 3-4<br />
3-5<br />
B630 1000 4 3-6<br />
3-7<br />
B630 4 3-6<br />
3-7<br />
BA126 2 3-17<br />
3-22<br />
BA135 3-22<br />
BA1546 3-29<br />
BA1553 3-29<br />
BA1575 1 3-29<br />
BA1588 3-31<br />
BA1589 3-31<br />
BA1594 3-22<br />
BA1595 3-22<br />
BA1671 3-29<br />
BA1678 3-29<br />
BA1700 1 3-29<br />
BA1713 3-31<br />
BA1714 3-31<br />
BA1720 3-24<br />
BA1721 3-24<br />
BA1796 3-29<br />
BA1799 3-29<br />
BA1803 3-29<br />
BA1838 3-31<br />
BA1839 3-31<br />
BA1845 3-24<br />
BA1846 3-24<br />
BA235 3-22<br />
BA435 3-22<br />
BA705 3-27<br />
BA904 3-28<br />
BA911 3-28<br />
BF00A 3-11<br />
BF09A 3-4<br />
BF09 T2A 3-11<br />
BF09 T4A 3-6<br />
BF110 00<br />
BF110C 00 3-5<br />
BF12A 3-4<br />
BF12C 3-5<br />
BF12 T4A 3-6<br />
BF16C 3-5<br />
BF16C 04 3-11<br />
BF16C 22 3-11<br />
BF16C 40 3-7<br />
BF18A 3-4<br />
BF18 T0A 3-11<br />
BF18 T2A 3-11<br />
BF18 T4A 3-6<br />
BF20C 3-5<br />
BF25A 3-4<br />
BF25C 3-5<br />
BF25C 04 3-11<br />
BF25C 22 3-11<br />
BF25C 40 3-7<br />
BF26 00A 3-4<br />
BF26 T2A 3-11<br />
BF26 T4A 3-7<br />
BF32 00A 3-4<br />
BF32C 3-5<br />
BF38 00A 3-4<br />
BF38 T2A 3-11<br />
BF38 T4A 3-6<br />
BF40C 00 3-5<br />
BF40C 22 3-11<br />
BF40C 40 3-7<br />
BF50 00 3-4<br />
BF50 40 3-6<br />
BF50C 00 3-5<br />
BF50K 00 3-8<br />
BF65 00 3-4<br />
BF65 40 3-6<br />
BF65C 00 3-5<br />
BF65C 40 3-7<br />
BF65K 00 3-8<br />
BF70K 00 3-8<br />
BF80 00 3-4<br />
BF80 40 3-6<br />
BF80C 00 3-5<br />
BF80C 40 3-7<br />
BF80K 00 3-8<br />
BF95 00 3-4<br />
BF95 C 00 3-4<br />
BF9C 3-5<br />
BF9C 40 3-7<br />
BFA42 6-8<br />
BFK09 3-8<br />
BFK12 3-8<br />
BFK18 3-8<br />
BFK26 3-8<br />
BFK32 3-8<br />
BFK38 3-8<br />
BFT 6-9<br />
BFU 6-8<br />
6-9<br />
BFX10 3-12<br />
4-5<br />
BFX11 3-12<br />
BFX30 5-5<br />
3-16<br />
4-5<br />
BFX31 3-16<br />
BFX32 3-16<br />
BFX42 3-15<br />
4-5<br />
BFX50 3-15<br />
4-5<br />
BFX79 3-14<br />
4-5<br />
BFX80 3-16<br />
4-5<br />
BFX89 1-5<br />
3-16<br />
4-5<br />
BFX95A 3-26<br />
BFX99 3-30<br />
BG00... 3-10<br />
BG00... D 3-11<br />
BG06... A 3-4<br />
BG06... D 3-5<br />
BG09... A 3-4<br />
BG09... D 3-5<br />
BG09 T2 3-11<br />
BG09 T4 A 3-5<br />
BG09 T4 D 3-7<br />
BG12... A 3-4<br />
BG12... D 3-7<br />
BGF00 3-10<br />
BGF09... A 3-7<br />
BGF09... D 3-7<br />
BGF09... L 3-7<br />
BGF09 T4 A 3-6<br />
BGF09 T4 D 3-7<br />
BGP09... A 3-4<br />
BGP09... D 3-5<br />
BGP09 T4 A 3-6<br />
BGP09 T4 D 3-7<br />
BGR 6-8<br />
6-9<br />
BGU 6-8<br />
6-9<br />
BGX 3-12<br />
4-3<br />
BT2N 10-7<br />
BTPM1220 10-5<br />
BTPM220 10-6<br />
C11 15-2<br />
C2 13-8<br />
15-3<br />
16-2<br />
16-3<br />
C4 13-7<br />
13-8<br />
15-3<br />
16-3<br />
C5 13-8<br />
15-3<br />
16-3<br />
C6 16-3<br />
C9 13-8<br />
15-3<br />
16-3<br />
CE106 10-7<br />
CE107 10-7<br />
CGL 12-3<br />
DCRJ 15-3<br />
DCRK 15-2<br />
DM1T 13-9<br />
DM2T 13-9<br />
DM3T 13-9<br />
DMK0 13-2<br />
DMK1 13-3<br />
13-4<br />
DMK2 13-7<br />
DMK3 13-8<br />
DMK40 13-8<br />
DMK5 13-7<br />
DMK6 13-8<br />
DMK7 13-4<br />
DMK8 13-2<br />
DMKSW 13-8<br />
DP 4-2<br />
4-3<br />
DRPL 10-6<br />
G218 3-14<br />
4-4<br />
G222 3-15<br />
G223 3-15<br />
G228 5-9<br />
G230 5-9<br />
G231 3-17<br />
G232 3-17<br />
G233 5-9<br />
G234 3-30<br />
G234 4 3-30<br />
G235 3-30<br />
G236 3-30<br />
G236 4 3-30<br />
G237 3-30<br />
G237 4 3-30<br />
G244 5-9<br />
G258 5-9<br />
G260 5-9<br />
G261 5-9<br />
G262 5-9<br />
G265 3-17<br />
G269 3-17<br />
G270 5-9<br />
G271 3-17<br />
G272 3-17<br />
G273 3-30<br />
G274 3-30<br />
G274 4 3-30<br />
G275 3-30<br />
G275 4 3-30<br />
G276 3-30<br />
G276 4 3-30<br />
G279 3-30<br />
G279 4 3-30<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com
I-II<br />
Index in alphanumeric order<br />
®<br />
electric<br />
G280 3-14<br />
4-4<br />
G281 3-17<br />
G285 3-17<br />
G291 5-9<br />
G318 3-15<br />
G319 225 3-15<br />
G322 3-15<br />
G350 3-22<br />
G354 3-22<br />
G355 3-22<br />
G356 3-22<br />
G358 3-22<br />
G360 3-22<br />
G361 3-22<br />
G362 3-22<br />
5-9<br />
G363 3-22<br />
5-9<br />
G370 3-22<br />
G371 3-22<br />
G372 5-9<br />
G373 5-9<br />
G375 5-9<br />
G376 5-9<br />
G380 3-31<br />
G380 4 3-31<br />
G381 3-31<br />
G381 4 3-31<br />
G382 3-31<br />
G382 4 3-31<br />
G383 3-31<br />
G383 4 3-31<br />
G384 3-31<br />
G384 4 3-31<br />
G385 3-31<br />
G385 4 3-31<br />
G418 3-14<br />
G430 5-9<br />
G460 3-8<br />
G464 3-8<br />
G470 3-30<br />
G470 4 3-30<br />
G475 3-30<br />
G476 3-30<br />
G481 3-14<br />
4-4<br />
G482 3-14<br />
4-4<br />
G483 3-14<br />
4-4<br />
G484 3-14<br />
4-4<br />
G485 3-14<br />
4-4<br />
G486 3-14<br />
4-4<br />
G487 3-14<br />
4-4<br />
G525 3-30<br />
G525 4 3-30<br />
G526 3-30<br />
G526 4 3-30<br />
G527 3-22<br />
G528 3-22<br />
G529 3-22<br />
G530 3-22<br />
G611 8-21<br />
9-17<br />
G612 8-21<br />
9-17<br />
G613 8-21<br />
9-17<br />
G614 8-21<br />
9-17<br />
G616 1-5<br />
9-16<br />
9-17<br />
G617 1-5<br />
9-16<br />
9-17<br />
G621 9-16<br />
9-17<br />
G622 9-16<br />
9-17<br />
GN...O68 9-13<br />
GN...O78 9-13<br />
GN...O79 9-13<br />
GN...O88 9-13<br />
GN...O98 9-13<br />
GN...O99 9-13<br />
GN...P 9-14<br />
9-15<br />
GN...P25 9-15<br />
GN...U 9-8<br />
8-9<br />
9-10<br />
9-11<br />
GN...U11 9-12<br />
GN...U12 9-12<br />
GN...U25 9-12<br />
GN...U65 9-12<br />
GUS...A 2-2<br />
GUS...C 2-3<br />
GUSH 2-3<br />
GUSS 2-3<br />
GXM 9-16<br />
9-17<br />
GX... U 9-2<br />
9-3<br />
9-4<br />
GX...U11 9-5<br />
GX...U12 9-5<br />
GX...U25 9-5<br />
GX...O68 9-6<br />
GX...O78 9-6<br />
GX...O88 9-6<br />
GX...O98 9-6<br />
GX...P 9-7<br />
GX...P25 9-7<br />
GXA01 9-16<br />
9-17<br />
GXA01H 9-16<br />
9-17<br />
GXA11 9-16<br />
9-17<br />
GXM1 9-16<br />
9-17<br />
GXM2 9-16<br />
9-17<br />
GXM5 9-16<br />
9-17<br />
GXM6 9-16<br />
K... A 8-2<br />
K... B 8-3<br />
K... C 8-4<br />
K... D 8-5<br />
K... E 8-6<br />
8-7<br />
K... F 8-8<br />
8-9<br />
K... H 8-10<br />
K... L 8-11<br />
K... M 8-12<br />
K... N 8-15<br />
K... P 8-13<br />
K... Q 8-14<br />
KG 8-24<br />
8-25<br />
KP 8-18<br />
KR 8-24<br />
8-25<br />
KS 8-23<br />
KXA 8-17<br />
KXB 8-17<br />
KXC 8-16<br />
KXP 8-17<br />
8-25<br />
L2PP1A5 7-16<br />
L2PP1A8 7-16<br />
L2PP2A8 7-16<br />
L2PP3A8 7-16<br />
L2PP4A8 7-16<br />
L2PP5A8 7-16<br />
L2PP100 7-16<br />
L2PP110 7-16<br />
L2PP115 7-16<br />
L2PP120 7-16<br />
L2PP130 7-16<br />
L2PP150 7-16<br />
L2PP160 7-16<br />
L2PP165 7-16<br />
L2PP170 7-16<br />
L2PP180 7-16<br />
L48AP 10-9<br />
L48M 10-8<br />
L48 P11 10-9<br />
L48 P8 10-9<br />
L48TP 10-8<br />
L48TPB 10-8<br />
LM2TA12 7-21<br />
LM2TA130 7-21<br />
LM2TA140 7-21<br />
LM2TA150 7-20<br />
LM2TA160 7-20<br />
LM2TA170 7-20<br />
LM2TA170G 7-20<br />
LM2TA180 7-21<br />
LM2TA185 7-20<br />
LM2TA190 7-20<br />
LM2TA200 7-21<br />
LM2TAGB21 7-19<br />
LM2TAGB2 7-19<br />
LM2TAGB23. 7-19<br />
LM2TAGB24 7-19<br />
LM2TAI23 7-19<br />
LM2TALA0 7-20<br />
LM2TALB0 7-20<br />
LM2TALB048 7-20<br />
LM2TALB130 7-20<br />
LM2TALL006 7-20<br />
LM2TALL024 7-20<br />
LM2TALL048 7-20<br />
LM2TALN 7-20<br />
LM2TALP 7-20<br />
LM2TAT 7-21<br />
LM2TAU10 7-20<br />
LM2TAU101 7-9<br />
LM2TAU106 7-20<br />
LM2TAU107 7-21<br />
LM2TAU108 7-20<br />
LM2TAU11 7-19<br />
LM2TAU120 7-17<br />
LM2TAU13 7-20<br />
LM2TAU14 7-22<br />
LM2TAU157 7-21<br />
LM2TAU167 7-20<br />
LM2TAU170 7-20<br />
LM2TAU20 7-19<br />
LM2TB1 7-2<br />
LM2TB2 7-2<br />
LM2TB3 7-3<br />
LM2TB6 7-3<br />
LM2TBL10 7-6<br />
LM2TBL20 7-6<br />
LM2TBL614 7-6<br />
LM2TBL624 7-6<br />
LM2TC 7-17<br />
LM2TDL400 7-18<br />
LM2TE 7-17<br />
LM2TEL400 7-18<br />
LM2TFL 7-18<br />
LM2TGL 7-18<br />
LM2TJ 7-9<br />
LM2TIL1 7-7<br />
LM2TL 7-18<br />
LM2TM 7-18<br />
LM2TP100 7-8<br />
LM2TP110 7-8<br />
LM2TR100 7-4<br />
LM2TR1196 7-4<br />
LM2TR2004 7-4<br />
LM2TS1 7-4<br />
LM2TS2 7-4<br />
LM2TS3 7-4<br />
LM2TS3...G 7-4<br />
LM2TSL12 7-7<br />
LM2TSL13 7-7<br />
LM2TT100 7-18<br />
LM2TVL230 7-18<br />
LM2TXL 7-18<br />
LM2TYL 7-18<br />
LM2TZL230 7-18<br />
LMA 1-11<br />
LMH 1-11<br />
LMM 1-11<br />
LMN 1-11<br />
LMS25 1-10<br />
LMU 1-11<br />
LMZ 1-11<br />
LP2TAU120 6-21<br />
LP2TB1 6-10<br />
LP2TB2 6-10<br />
L2PTB3 6-10<br />
L2PTB6 6-11<br />
LP2TB71 6-12<br />
LP2TB72 6-12<br />
LP2TB7233 6-12<br />
LP2TB73 6-12<br />
LP2TBL10 6-14<br />
LP2TBL20 6-14<br />
LP2TBL614 6-14<br />
LP2TBL71 6-15<br />
LP2TBL7133 6-15<br />
LP2TBL72 6-15<br />
LP2TBL7233 6-15<br />
LP2TIL2 6-15<br />
LP2TR100 6-11<br />
LP2TR1196 6-11<br />
LP2TR2004 6-11<br />
LP2TS1 6-13<br />
LP2TS2 6-13<br />
LP2TS3 6-13<br />
LP2TS3G 6-13<br />
LP2TSL12 6-14<br />
LP2TSL13 6-14<br />
LRD 17-2<br />
LRE 17-2<br />
LVM20 12-2<br />
LVM25 12-2<br />
LVM30 12-2<br />
LVM40 12-3<br />
LVMP 12-5<br />
M...BRF P 6-2<br />
M...BRF R 6-2<br />
M...N 6-4<br />
M...PA 6-4<br />
M...RA 6-4<br />
M0P 6-2<br />
M0R 6-2<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com
®<br />
electric<br />
Index in alphanumeric order<br />
I-III<br />
M1P 6-2<br />
M1R 6-2<br />
M2 6-4<br />
M2P 6-2<br />
M2R 6-2<br />
M3 6-4<br />
M3P 6-4<br />
M3R 6-4<br />
MX 6-4<br />
NEONV 1-5<br />
1-11<br />
NEONR 1-5<br />
1-11<br />
NTC01 15-3<br />
P330 8-22<br />
PA96X96 13-7<br />
13-8<br />
15-2<br />
PACR 15-2<br />
15-3<br />
16-2<br />
16-3<br />
PMA 11-4<br />
11-5<br />
PMF 11-5<br />
PMV10 11-2<br />
PMV20 11-2<br />
PMV30 11-2<br />
PMV40 11-3<br />
PMV50 11-3<br />
PMV55 11-2<br />
PMV60 11-3<br />
PMV70 11-3<br />
PS31 12-4<br />
PS35 12-4<br />
PX1 13-8<br />
15-3<br />
16-3<br />
RB6 5-9<br />
RE213 12-4<br />
RE244 3-15<br />
RF200 5-8<br />
RF25 5-4<br />
RF420 5-8<br />
RF9 5-2<br />
RF95 5-4<br />
RFA 5-2<br />
5-4<br />
5-5<br />
RFS 5-3<br />
5-6<br />
RFSA 5-7<br />
RS1 8-21<br />
RS2 8-21<br />
RS3 8-21<br />
RS13 8-22<br />
S11 10-9<br />
S8 10-9<br />
SCM 12-4<br />
SM1B 1-2<br />
SM2A 1-3<br />
SM3A 1-3<br />
SMX1 1-4<br />
1-5<br />
SMX2 1-8<br />
SMX9003 1-5<br />
SMX9010 1-5<br />
SMX9012 1-5<br />
SMX9014 1-5<br />
SMX9018 1-5<br />
SMX9019 1-5<br />
SN1 12-3<br />
TL... C1 8-19<br />
TL...01 8-19<br />
TL...05 8-20<br />
TL...09 8-20<br />
TL...10 8-20<br />
8-21<br />
TL...11 8-20<br />
TL...12 8-23<br />
TL...13 8-21<br />
8-22<br />
TMD 10-3<br />
TM LS 10-4<br />
TM M 10-2<br />
TM P 10-2<br />
TM PL 10-3<br />
TM ST 10-3<br />
TS...01 8-19<br />
TS...05 8-19<br />
TS...09 8-20<br />
TS13 8-21<br />
8-22<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com
LOVATO ELECTRIC CORP.<br />
Terms and Conditions of Sale in Canada<br />
The following terms and conditions of sale are subject to change.<br />
1. GENERAL: These terms and conditions of sale apply to all sales of<br />
Lovato <strong>Electric</strong> Corp. (Seller), unless modified in writing by Seller.<br />
Seller expressly rejects any other terms and conditions as may be<br />
proposed by the Purchaser. A contract upon the conditions and<br />
terms herein (including terms of identification of products,<br />
quantity, shipping and billing) shall be deemed to have been<br />
entered into when, on receipt of an order, Seller acknowledges<br />
acceptance in writing. All terms and conditions are printed on<br />
invoices. All sales are governed by and subject to the laws of the<br />
Province of Quebec without regard to its conflicts of laws<br />
provisions.<br />
Contact Seller for all other details in English or French.<br />
2. TECHNICAL INFORMATION: Documents such as catalogs,<br />
drawings, and specifications related to products sold by the Seller<br />
are to be used only as an approximate guide and may not reflect<br />
latest designs or accurate technical details of products. Seller<br />
reserves the right to make any changes in its products that it<br />
considers necessary in its sole discretion.<br />
®<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com<br />
electric
LOVATO ELECTRIC INC.<br />
Terms and Conditions of Sale in the U.S.A.<br />
The following terms and conditions of sale are subject to change.<br />
1. GENERAL: These terms and conditions of sale apply to all sales of<br />
Lovato <strong>Electric</strong>, Inc (Seller), unless modified in writing by Seller.<br />
Seller expressly rejects any other terms and conditions as may be<br />
proposed by the Purchaser. A contract upon the conditions and<br />
terms herein (including terms of identification of products,<br />
quantity, shipping and billing) shall be deemed to have been<br />
entered into when, on receipt of an order, Seller acknowledges<br />
acceptance in writing. All sales are governed by and subject to<br />
the laws of the Commonwealth of Virginia without regard to its<br />
conflicts of laws provisions.<br />
2. TECHNICAL INFORMATION: Documents such as catalogs,<br />
drawings, and specifications related to products sold by the Seller<br />
are to be used only as an approximate guide and may not reflect<br />
latest designs or accurate technical details of products. Seller<br />
reserves the right to make any changes in its products that it<br />
considers necessary in its sole discretion.<br />
3. PRICES AND QUOTATIONS: Prices are subject to change without<br />
notice. Written or verbal quotations are valid for 30 days.<br />
4. TERMS OF PAYMENT: Terms of payment are Net thirty (30) days<br />
from date of invoice with approved credit as determined by Seller.<br />
Seller retains exclusive right to determine credit worthiness of<br />
Purchaser. Payments shall be made in U.S. currency to address of<br />
Seller without any deductions of any kind. Unpaid accounts may<br />
result in interruption of supply. In addition, interest may accrue at<br />
the rate of 1 1/2% per month on unpaid balances but not to<br />
exceed the maximum permitted by law.<br />
5. DELIVERY: Delivery terms are FCA, Free Carrier (INCOTERMS<br />
2000) Seller’s facility, Chesapeake, Virginia with respect to<br />
shipping costs, risk of loss and title transfer. Seller will not be<br />
liable for any loss, damage or delay arising out of its failure to<br />
perform hereunder due to causes beyond its reasonable control,<br />
including without limitation, acts of God or the Purchaser, acts of<br />
civil or military authority, fires, strikes, floods, epidemics,<br />
quarantine restrictions, war, riots, raw materials shortages, delays<br />
in transportation, or transportation embargoes. In the event of any<br />
such delay, Seller’s performance date(s) will be extended for that<br />
length of time as may be reasonably necessary to compensate for<br />
the delay.<br />
6. SHIPPING TIMES: Acknowledged dates of delivery in accordance<br />
with Paragraph 5 are approximate and are based on receipt of all<br />
necessary information, required materials to complete the order,<br />
are dependent on prevailing conditions at the time of quotation,<br />
and are not guaranteed.<br />
7. LIMITED WARRANTY: Seller warrants for a period of one (1)<br />
year from delivery in accordance with Paragraph 5, that product<br />
manufactured by it will be free from defects solely due to<br />
material, workmanship and design. This warranty does not cover<br />
defects caused by wear and tear, accident, misuse, improper<br />
installation,or neglect, as determined solely by Seller. Warranty<br />
shall be limited to Seller’s option of repair or replacement at<br />
Seller’s facility. With respect to equipment sold but not<br />
manufactured by Seller, the warranty obligations of Seller shall in<br />
all respects conform and be limited to the warranty actually<br />
extended to Seller by the manufacturer. The foregoing warranties<br />
do not cover reimbursement for labor, transportation, removal,<br />
installation or other expenses which may be incurred in<br />
connection with repair or replacement.<br />
THESE WARRANTIES ARE EXCLUSIVE AND ARE IN LIEU OF<br />
ALL OTHER WARRANTIES WHETHER EXPRESSED, IMPLIED OR<br />
STATUTORY, INCLUDING IMPLIED WARRANTIES OF<br />
MERCHANTABILITY OR FITNESS FOR A PARTICULAR<br />
PURPOSE, OR PERFORMANCE OR APPLICATION WARRANTIES.<br />
8. EXCLUSION OF DAMAGES: IN NO EVENT WILL SELLER BE<br />
LIABLE FOR INCIDENTAL, INDIRECT, SPECIAL, PUNITIVE,<br />
EXEMPLARY, OR CONSEQUENTIAL DAMAGES, OR ANY OTHER<br />
PECUNIARY OR OTHER LOSS WHATSOEVER OF ANY KIND<br />
ARISING OUT OF OR IN ANY WAY CONNECTED WITH<br />
PRODUCTS SOLD BY IT. SELLER’S MAXIMUM CUMULATIVE<br />
LIABILITY IS PURSUANT ONLY TO PARAGRAPH 7 AND WILL<br />
NOT EXCEED THE COST OF THE PRODUCTS SUBJECT TO<br />
WARRANTY. THESE LIMITATIONS AND EXCLUSIONS<br />
REGARDING DAMAGES APPLY EVEN IF ANY REMEDY FAILS.<br />
9. RETURNS: All returns of Products must be approved in writing<br />
by Seller prior to return. Non-warranty returns of unused and<br />
salable Products for credit will be subject to Seller’s return<br />
policies in effect at the time, including applicable restocking<br />
charges and other conditions of return. Products returned<br />
under warranty must be properly packed and shipped to<br />
Seller-specified locations.<br />
10. CANCELLATIONS: Any order or partial order cancelled or<br />
suspended by Purchaser is subject to express written consent<br />
of Seller. Seller may impose and Purchaser hereby agrees to<br />
pay reasonable cancellation charges which reflect costs up to<br />
the time of cancellation or suspension.<br />
11. GOVERNMENT REGULATIONS: No government contract<br />
regulations or clauses will apply to the Products or this<br />
agreement or act to bind Seller unless specifically agreed to by<br />
Seller in writing. Products sold hereunder are not intended to be<br />
used, nor should they be used, in any nuclear-related application<br />
either as a “Basic Component” under 10 CFR 21 (United States<br />
NRC) or otherwise under similar nuclear laws and regulations of<br />
this or any other country.<br />
®<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com<br />
electric
GENERAL INFORMATION<br />
Typical Full Load Currents<br />
For Single and Three Phase <strong>Electric</strong> Motors<br />
The information in the chart below was obtained from the National<br />
<strong>Electric</strong> Code Table 430-148 and 430-150 and from U.L. Industrial<br />
Control Standard 508. The voltages shown are standard rated motor<br />
voltages. The currents listed are permitted for system voltage ranges<br />
of 110-120, 220-240, 440-480, and 550-600 volts.<br />
The full load current values listed are for motors running at standard<br />
speeds with normal torque characteristics. Motors which are<br />
non-standard, such as low speed, high torque or other special<br />
applications may have higher full load currents.<br />
Caution: For accurate and reliable motor protection, motor nameplate<br />
current should be used to obtain actual motor full load amps for all<br />
motors.<br />
Inductive Motor - 60Hz 3 Phase [A]<br />
Horsepower Single Phase Three Phase<br />
120V 240V 200V 240V 480V 600V<br />
1<br />
/10 3.0 1.5<br />
1<br />
/8 3.8 1.9<br />
1<br />
/6 4.4 2.2<br />
1<br />
/4 5.8 2.9<br />
1<br />
/3 7.2 3.6<br />
1<br />
/2 9.8 4.9 2.5 2.2 1.1 0.9<br />
3 /4 13.8 6.9 3.2 2.8 1.4 1.1<br />
1 16 8 4.8 4.2 2.1 1.7<br />
1 1 /2 20 10 6.9 6 3 2.4<br />
2 24 12 7.8 6.8 3.4 2.7<br />
3 34 17 11 9.6 4.8 3.9<br />
5 56 28 17.5 15.2 7.6 6.1<br />
7 1 /2 80 40 25.3 22 11 9<br />
10 100 50 32.2 28 14 11<br />
15 135 68 48.3 42 21 17<br />
20 62.1 54 27 22<br />
25 78.2 68 34 27<br />
30 92 80 40 32<br />
40 120 104 52 41<br />
50 150 130 65 52<br />
60 177 154 77 62<br />
75 221 192 96 77<br />
100 285 248 124 99<br />
125 359 312 156 125<br />
150 414 360 180 144<br />
200 552 480 240 192<br />
250 604 302 242<br />
300 722 361 289<br />
350 828 414 336<br />
400 954 477 382<br />
®<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />
Web : www.A-Aelectric.com Email: njsales@a-aelectric.com<br />
electric
USA<br />
®<br />
CAN<br />
claro@cyberg.it<br />
®<br />
electric<br />
100% electricity<br />
LOVATO ELECTRIC INC.<br />
124 Robert Hall Court 109<br />
CHESAPEAKE, VA 23324<br />
USA<br />
tel: (757) 545.4700<br />
fax: (757) 545.2900<br />
e-mail: info@LovatoUsa.com<br />
www.LovatoUsa.com<br />
LOVATO ELECTRIC CORP.<br />
3200 Avenue Jacques Bureau<br />
LAVAL, QC H7P 0A9<br />
Canada<br />
tel: (450) 681.9200<br />
fax: (450) 681.9884<br />
e-mail: info@Lovato.ca<br />
www.Lovato.ca<br />
PC01 US/CD 09 06<br />
2007-2008<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 • Lakeland, FL • Lawrenceville, GA • East Rutherford, NJ<br />