Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />

<strong>KT7</strong> <strong>Motor</strong> <strong>Circuit</strong> <strong>Controllers</strong><br />

<strong>Motor</strong> <strong>Circuit</strong> <strong>Controllers</strong> – General Description ............................................F2<br />

Series KTA7 & KTA3-100 Base Units ..........................................................F4<br />

Series KTC7 Base Units ..............................................................................F6<br />

Series KTB7 Base Units ..............................................................................F8<br />

Accessories ..........................................................................................F10<br />

Type 2 Coordination ..............................................................................F20<br />

Technical Information – <strong>KT7</strong> .................................................................F22<br />

Dimensions – <strong>KT7</strong> ................................................................................F35<br />

Technical Information – KTA3-100 ........................................................F38<br />

Dimensions – KTA3-100 .......................................................................F43<br />

Ecombo and EcomboPlus <strong>Starters</strong> – General Description .....................F44<br />

CL4 / CLU4 Ecombo <strong>Starters</strong> .....................................................................F46<br />

CL7 / CLU7 Ecombo <strong>Starters</strong> .....................................................................F48<br />

CK7 / CKU7 EcomboPlus <strong>Starters</strong> ..............................................................F50<br />

Factory Options .....................................................................................F53<br />

<strong>KT7</strong> Assembly – Application Rating Chart ..............................................F54<br />

Wiring Diagrams ...................................................................................F56<br />

Dimensions ...........................................................................................F57<br />

Enclosed <strong>KT7</strong> <strong>Motor</strong> <strong>Circuit</strong> <strong>Controllers</strong> ..................................................F63<br />

<strong>Manual</strong> Combo .....................................................................................F64<br />

CX7 Combo ...........................................................................................F68<br />

Explosion-proof <strong>KT7</strong> <strong>Motor</strong> <strong>Controllers</strong> ..................................................F73<br />

Dimensions and Technical Info. .............................................................F76<br />

<strong>Motor</strong> Current Rating Chart ...................................................................F80<br />

Methods of Applying <strong>KT7</strong> <strong>Motor</strong> <strong>Circuit</strong> <strong>Controllers</strong> ...............................F81<br />

<strong>KT4</strong> <strong>Manual</strong> <strong>Motor</strong> <strong>Starters</strong><br />

Table of Content .........................................................................................F89<br />

<strong>Manual</strong> <strong>Motor</strong> Staters – General Description ..............................................F90<br />

Quick Selection Guide ................................................................................F91<br />

Accessories ...............................................................................................F92<br />

Explosion Proof <strong>Manual</strong> Starter Type EV3 ..............................................F96<br />

Technical Information .................................................................................F97<br />

Dimensions ..............................................................................................F102<br />

F<br />

<strong>Motor</strong> <strong>Circuit</strong><br />

<strong>Controllers</strong><br />

<strong>KT7</strong><br />

F1


F<br />

<strong>Motor</strong> <strong>Circuit</strong><br />

<strong>Controllers</strong><br />

Series <strong>KT7</strong><br />

<strong>Motor</strong> <strong>Circuit</strong><br />

<strong>Controllers</strong><br />

Versatile, convenient<br />

and space saving…<br />

for a variety of<br />

applications<br />

R<br />

Sprecher+Schuh’s new <strong>KT7</strong> series of<br />

<strong>Motor</strong> <strong>Circuit</strong> <strong>Controllers</strong> are some of<br />

the most versatile and technologically<br />

advanced control products available<br />

today.<br />

In one small package, <strong>KT7</strong>s combine<br />

the functions of:<br />

• Current limiting short circuit<br />

protection<br />

• Class 10 thermal overload<br />

protection<br />

• Switching and<br />

• Signaling<br />

These devices can be used in a<br />

variety of control schemes that<br />

reduce panel space, simplify installation<br />

and eliminate the need for more<br />

expensive equipment.<br />

New models…<br />

Increased ratings…<br />

Sprecher+Schuh’s <strong>KT7</strong> controller family<br />

has been expanded with the introduction<br />

of our new <strong>KT7</strong> line, which<br />

offers higher interrupting capacities<br />

(KAIC ratings), improved Type 2 Coordination<br />

and a midsize frame rated<br />

to 45A (see photo below). In addition,<br />

the line has been expanded to include<br />

a new “high break” 25A device which<br />

offers 65kA of short circuit protection<br />

in applications up to 20 FLA.<br />

Designed for multiple applications<br />

New UL rules allow <strong>KT7</strong> <strong>Motor</strong> <strong>Circuit</strong><br />

<strong>Controllers</strong> to be used in a wide<br />

variety of applications including:<br />

• <strong>Manual</strong> Starter Applications<br />

• Traditional Group <strong>Motor</strong> Applications<br />

with compliance to the new<br />

Tap Conductor Ratings<br />

• <strong>Motor</strong> Disconnect Applications<br />

• Self-Protected <strong>Manual</strong> Combination<br />

Starter Applications (Type E)<br />

• Individual Combination Starter Applications<br />

• Multi-motor Starter Combination<br />

Applications<br />

Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />

<strong>KT7</strong><br />

F2<br />

45mm<br />

(≈1 3/4˝)<br />

25A<br />

Standard Interrupting Capacity<br />

45mm<br />

(≈1 3/4˝)<br />

25A<br />

High Interrupting Capacity<br />

54mm<br />

(≈2 1/8˝)<br />

45A<br />

High Interrupting Capacity<br />

80mm<br />

(≈3 5/16˝)<br />

High Interrupting Capacity<br />

90A


Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />

Construction Type E Listing<br />

Improved current limiting and breaking<br />

capacity has allowed <strong>KT7</strong>s to<br />

be UL / CSA listed as self-protected<br />

(Construction Type E) manual combination<br />

motor controllers. This eliminates<br />

the need for an upstream fuse or<br />

circuit breaker when using the <strong>KT7</strong> as<br />

a manual motor starter. In addition,<br />

<strong>KT7</strong>s also meet UL requirements for<br />

<strong>KT7</strong>s meet UL requirements for Type E manual<br />

motor controllers and “at-motor disconnects”<br />

Excellent short circuit<br />

protection characteristics<br />

In the event of a short-circuit, the<br />

contacts are opened by magnetic,<br />

non-adjusting tripping elements in<br />

times approaching 3/1000 of a second.<br />

This results in the extremely<br />

rapid buildup of an arc voltage which<br />

limits the current of the short-circuit<br />

to a very low level. Because of this<br />

superb current limiting capability,<br />

KTA <strong>Motor</strong> <strong>Circuit</strong> <strong>Controllers</strong> have<br />

a short circuit capacity of up to 65kA<br />

at 480V and up to 47kA at 600V (see<br />

illustration below).<br />

<strong>Manual</strong> <strong>Motor</strong> Starter Ratings<br />

65kA<br />

<strong>KT7</strong>-25S<br />

<strong>KT7</strong>-25H<br />

“at-motor disconnects,” which means<br />

they can be used in an enclosure with a<br />

lockable handle as a manual motor starter<br />

for individual circuits, and are also an<br />

approved means of motor disconnect.<br />

Type E + Combo starter +<br />

Economy = “Ecombo” starter<br />

When the <strong>KT7</strong> self-protected manual<br />

combination starter is combined with<br />

Sprecher + Schuh’s CA7 contactor to<br />

provide remote operation, we now have<br />

an alternative to the classic combination<br />

starter. We call these “Ecombo” starters,<br />

which save significant dollars and panel<br />

space over conventional combo starters.<br />

Ecombo starters are available for applications<br />

up to 15HP (@460/600V).<br />

25kA<br />

Superb thermal overload<br />

protection<br />

Every <strong>KT7</strong> device is individually calibrated<br />

at the factory for the smallest<br />

and largest current it can handle. When<br />

coupled with automatic ambient temperature<br />

compensation over a range of<br />

-25°C to +60°C, very accurate thermal<br />

overload protection is obtained. In addition,<br />

the <strong>KT7</strong> is a Class 10 device…<br />

it trips within 10 seconds under locked<br />

rotor conditions (6 x FLA). This better<br />

protects today’s T-Frame motors.<br />

30kA<br />

See a complete explanation of<br />

Ecombo starters beginning on page<br />

F40 of this catalog.<br />

65kA<br />

50kA<br />

<strong>KT7</strong>-45H<br />

Special units<br />

for special<br />

applications<br />

KTC7 controllers are available<br />

with a fixed magnetic<br />

trip set at 16…20x the<br />

maximum value of the<br />

current adjustment range<br />

(as opposed to 13x for the<br />

Multi-motor applications…<br />

Popular and money saving<br />

Because of the <strong>KT7</strong>’s new Construction<br />

Type E – UL Rating as a<br />

self-protected combination starter,<br />

many group motor installations can<br />

utilize an even simpler design and less<br />

expensive equipment. The result is<br />

minimum panel size and maximum<br />

flexibility while avoiding cumbersome<br />

NEC group motor rules.<br />

Using <strong>KT7</strong>s in Multi-<strong>Motor</strong> Starter applications<br />

can replace classic Branch <strong>Circuit</strong> Protection<br />

Devices and reduce panel space up to 60%<br />

KTA and KTB7). This prevents nuisance<br />

tripping in applications utilizing<br />

high efficiency motors for example.<br />

The KTB7 model is available without<br />

the thermal trip feature if a separate<br />

motor overload is required.<br />

Other protection features<br />

All <strong>KT7</strong> <strong>Motor</strong> <strong>Circuit</strong> <strong>Controllers</strong><br />

provide accelerated tripping under<br />

single phase conditions. This is accomplished<br />

with a special “differential<br />

tripping” mechanism built into each<br />

device.<br />

All <strong>KT7</strong> <strong>Motor</strong> <strong>Circuit</strong> <strong>Controllers</strong> offer accelerated<br />

tripping under single phase conditions<br />

F<br />

<strong>Motor</strong> <strong>Circuit</strong><br />

<strong>Controllers</strong><br />

<strong>KT7</strong><br />

F3


<strong>Motor</strong> <strong>Circuit</strong> Controller<br />

Series KTA7 / KTA3-100<br />

KTA7 Base Unit<br />

F<br />

<strong>Motor</strong> <strong>Circuit</strong><br />

<strong>Controllers</strong><br />

Typical<br />

Single<br />

Phase<br />

Maximum Horsepower<br />

Typical<br />

Three Phase [HP]<br />

115V 230V 200V 230V 460V 575V<br />

Current<br />

Adjustment<br />

Range [A]<br />

KTA7-25S — Standard Interrupting Capacity<br />

Horsepower ratings shown in the table are for reference only.<br />

The final selection of the manual starter depends on the actual<br />

motor full load current and service factor.<br />

• For motor with service factor less than 1.15. Use motor nameplate full load<br />

current times 0.9 and choose the motor starter with the appropriate current<br />

range. Example: <strong>Motor</strong> F.L.C. = 4.2A; S.F. = 1.0. – 4.2A x 0.9 = 3.78A.<br />

Select Catalog Number KTA7-25S-4.0A.<br />

Magnetic<br />

Release<br />

Response<br />

Current [A] Catalog Number Price<br />

~ ~ ~ ~ ~ ~ 0.10...0.16 2.1 KTA7-25S-0.16A 133<br />

~ ~ ~ ~ ~ ~ 0.16...0.25 3.3 KTA7-25S-0.25A 133<br />

~ ~ ~ ~ ~ ~ 0.25...0.40 5.2 KTA7-25S-0.4A 133<br />

~ ~ ~ ~ ~ ~ 0.40...0.63 8.2 KTA7-25S-0.63A 154<br />

~ ~ ~ ~ 1/2 3/4 0.63...1.0 13 KTA7-25S-1A 154<br />

~ 1/10 ~ ~ 1 1 1.0...1.6 21 KTA7-25S-1.6A 154<br />

1/10 1/6 1/2 3/4 1-1/2 2 1.6...2.5 33 KTA7-25S-2.5A 154<br />

1/8 1/3 1 1 3 3 2.5...4 52 KTA7-25S-4A 154<br />

1/4 3/4 1-1/2 2 5 5 4...6.3 82 KTA7-25S-6.3A 154<br />

1/2 1-1/2 3 3 7-1/2 10 6.3...10 130 KTA7-25S-10A 154<br />

1 3 3 5 10 15 10...16 208 KTA7-25S-16A 176<br />

1-1/2 3 5 7-1/2 15 20 14.5...20 260 KTA7-25S-20A 176<br />

2 3 7-1/2 7-1/2 15 20 18...25 325 KTA7-25S-25A 176<br />

KTA7-25H — High Interrupting Capacity<br />

1/10 1/6 1/2 3/4 1-1/2 2 1.6...2.5 33 KTA7-25H-2.5A 193<br />

1/8 1/3 1 1 3 3 2.5...4 52 KTA7-25H-4A 193<br />

1/4 3/4 1-1/2 2 5 5 4...6.3 82 KTA7-25H-6.3A 193<br />

1/2 1-1/2 3 3 7-1/2 10 6.3...10 130 KTA7-25H-10A 220<br />

1 3 3 5 10 15 10...16 208 KTA7-25H-16A 220<br />

1-1/2 3 5 7-1/2 15 20 14.5...20 260 KTA7-25H-20A 220<br />

2 3 7-1/2 7-1/2 15 20 18...25 325 KTA7-25H-25A 220<br />

KTA7-45H — High Interrupting Capacity<br />

1/2 1-1/2 3 3 7-1/2 10 6.3...10 130 KTA7-45H-10A 309<br />

1 3 3 5 10 15 10...16 208 KTA7-45H-16A 309<br />

1-1/2 3 5 7-1/2 15 20 14.5...20 260 KTA7-45H-20A 309<br />

2 5 5 7-1/2 20 25 18...25 325 KTA7-45H-25A 309<br />

2 5 10 10 25 30 23...32 416 KTA7-45H-32A 347<br />

3 7-1/2 15 15 30 40 32...45 585 KTA7-45H-45A 347<br />

KTA3-100 — High Interrupting Capacity<br />

2 5 1-1/2 10 20 25 16...25 350 KTA3-100-25A 326<br />

3 7-1/2 10 15 30 40 25...40 560 KTA3-100-40A 384<br />

5 10 20 20 50 60 40...63 882 KTA3-100-63A 384<br />

7-1/2 20 30 30 60 75 63...90 1260 KTA3-100-90A 420<br />

Catalog Number KTA7-25S<br />

Catalog Number KTA7-25H<br />

Catalog Number KTA7-45H<br />

Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />

<strong>KT7</strong><br />

F4<br />

Discount Schedule A-1


<strong>Motor</strong> <strong>Circuit</strong> Controller<br />

Series KTA7 / KTA3-100<br />

Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />

KTA7 UL Ratings Application Chart<br />

<strong>Manual</strong> <strong>Motor</strong><br />

Starter<br />

Max. Short <strong>Circuit</strong><br />

Current [kA]<br />

<strong>Manual</strong> Controller for Group<br />

Installation ➊<br />

Max. Fuse<br />

or <strong>Circuit</strong><br />

Breaker<br />

Max. Short <strong>Circuit</strong><br />

Current [kA]<br />

➊ UL 508, CSA 22.2 No. 14 for group installation, in connection with short-circuit<br />

protection device.<br />

➋ UL 508 Part III.<br />

➌ UL 508 Part IV.<br />

➍ Type E applications require use of the <strong>KT7</strong>-xx-TE terminal adaptor on <strong>KT7</strong>s<br />

produced after July 16, 2001.<br />

➎ Requires lockable twist knob (<strong>KT7</strong>-KN or <strong>KT7</strong>-KRY) or lockable door coupling<br />

handle (<strong>KT7</strong>-HTN or <strong>KT7</strong>-HTRY). See page F14.<br />

<strong>Manual</strong> Controller<br />

as <strong>Motor</strong><br />

Disconnect ➋➎<br />

Max. Short <strong>Circuit</strong><br />

Current [kA]<br />

Suitable for Tap<br />

Conductor Protection<br />

Max. Short <strong>Circuit</strong><br />

Current [kA]<br />

Self-Protected Type E<br />

<strong>Manual</strong> Combination<br />

Controller ➌➍➎<br />

Max. Short <strong>Circuit</strong><br />

Current [kA]<br />

Device<br />

480V 600V 480V 600V 480V 600V 480Y/277V 600Y/347V 480Y/277V 600Y/347V<br />

KTA7-25S — Standard Interrupting Capacity<br />

KTA7-25S-0.16A 65 47 450 65 47 65 47 65 47 65 47<br />

KTA7-25S-0.25A 65 47 450 65 47 65 47 65 47 65 47<br />

KTA7-25S-0.4A 65 47 450 65 47 65 47 65 47 65 47<br />

KTA7-25S-0.63A 65 47 450 65 47 65 47 65 47 65 47<br />

KTA7-25S-1A 65 47 450 65 47 65 47 65 47 65 47<br />

KTA7-25S-1.6A 65 47 450 65 47 65 47 65 47 65 47<br />

KTA7-25S-2.5A 65 30 450 65 30 65 30 65 30 65 30<br />

KTA7-25S-4A 65 25 450 65 25 65 25 65 25 65 25<br />

KTA7-25S-6.3A 65 30 450 65 30 65 30 65 ~ 65 ~<br />

KTA7-25S-10A 65 30 450 65 30 65 30 65 ~ 65 ~<br />

KTA7-25S-16A 30 30 450 30 30 30 30 30 ~ 30 ~<br />

KTA7-25S-20A 30 30 450 30 30 10 10 10 ~ 10 ~<br />

KTA7-25S-25A 25 10 450 25 10 10 5 ~ ~ ~ ~<br />

KTA7-25H — High Interrupting Capacity<br />

KTA7-25H-2.5A 65 30 450 65 30 65 30 65 30 65 30<br />

KTA7-25H-4A 65 30 450 65 30 65 30 65 30 65 30<br />

KTA7-25H-6.3A 65 30 450 65 30 65 30 65 30 65 30<br />

KTA7-25H-10A 65 30 450 65 30 65 30 65 30 65 30<br />

KTA7-25H-16A 65 30 450 65 30 65 30 65 30 65 30<br />

KTA7-25H-20A 65 30 450 65 30 65 30 65 ~ 65 ~<br />

KTA7-25H-25A 30 30 450 30 30 30 30 30 ~ 30 ~<br />

KTA7-45H — High Interrupting Capacity<br />

KTA7-45H-10A 65 30 600 65 30 65 30 65 30 65 30<br />

KTA7-45H-16A 65 30 600 65 30 65 30 65 30 65 30<br />

KTA7-45H-20A 65 30 600 65 30 65 30 65 30 65 30<br />

KTA7-45H-25A 65 30 600 65 30 65 30 65 30 65 30<br />

KTA7-45H-32A 65 30 600 65 30 65 30 65 30 65 30<br />

KTA7-45H-45A 65 18 600 65 18 65 18 65 ~ 65 ~<br />

KTA3-100 — High Interrupting Capacity<br />

KTA3-100-25A 65 42 1000 65 42 ~ ~ ~ ~ ~ ~<br />

KTA3-100-40A 65 42 1000 65 42 ~ ~ ~ ~ ~ ~<br />

KTA3-100-63A 42 18 1000 42 18 ~ ~ ~ ~ ~ ~<br />

KTA3-100-90A 35 10 1000 35 10 ~ ~ ~ ~ ~ ~<br />

It should be noted that the <strong>KT7</strong> <strong>Manual</strong> <strong>Motor</strong> <strong>Circuit</strong> Controller, when listed as a<br />

self-protected (Type E) device, is rated for Wye-connected power systems for<br />

voltages above 240 volts (i.e. 480Y / 277 volts common in the United States or<br />

600Y/ 347 volts common in Canada).<br />

F<br />

<strong>Motor</strong> <strong>Circuit</strong><br />

<strong>Controllers</strong><br />

<strong>KT7</strong><br />

Discount Schedule A-1<br />

F5


<strong>Motor</strong> <strong>Circuit</strong> Controller<br />

Series KTC7<br />

KTC7 Base Unit<br />

F<br />

<strong>Motor</strong> <strong>Circuit</strong><br />

<strong>Controllers</strong><br />

Typical<br />

Single<br />

Phase<br />

Maximum Horsepower<br />

Typical<br />

Three Phase [HP]<br />

Current<br />

Adjustment<br />

Range [A]<br />

Horsepower ratings shown in the table are for reference only.<br />

The final selection of the manual starter depends on the actual<br />

motor full load current and service factor.<br />

• For motor with service factor less than 1.15. Use motor nameplate full load<br />

current times 0.9 and choose the motor starter with the appropriate current<br />

range. Example: <strong>Motor</strong> F.L.C. = 4.2A; S.F. = 1.0. – 4.2A x 0.9 = 3.78A.<br />

Select Catalog Number KTA7-25S-4.0A.<br />

Magnetic<br />

Release<br />

Response<br />

Current [A] Catalog Number Price<br />

115V 230V 200V 230V 460V 575V<br />

KTC7-25S — Standard Interrupting Capacity<br />

~ ~ ~ ~ ~ ~ 0.10...0.16 3.3 KTC7-25S-0.16A 133<br />

~ ~ ~ ~ ~ ~ 0.16...0.25 5.2 KTC7-25S-0.25A 133<br />

~ ~ ~ ~ ~ ~ 0.25...0.40 8.2 KTC7-25S-0.4A 133<br />

~ ~ ~ ~ ~ ~ 0.40...0.63 13 KTC7-25S-0.63A 154<br />

~ ~ ~ ~ 1/2 3/4 0.63...1.0 21 KTC7-25S-1A 154<br />

~ 1/10 ~ ~ 1 1 1.0...1.6 33 KTC7-25S-1.6A 154<br />

1/10 1/6 1/2 3/4 1-1/2 2 1.6...2.5 52 KTC7-25S-2.5A 154<br />

1/8 1/3 1 1 3 3 2.5...4 82 KTC7-25S-4A 154<br />

1/4 3/4 1-1/2 2 5 5 4...6.3 130 KTC7-25S-6.3A 154<br />

1/2 1-1/2 3 3 7-1/2 10 6.3...10 208 KTC7-25S-10A 154<br />

1 3 3 5 10 15 10...16 260 KTC7-25S-16A 176<br />

KTC7-25H — High Interrupting Capacity<br />

1 3 3 5 10 15 10...16 260 KTC7-25H-16A 220<br />

1-1/2 3 5 7-1/2 15 20 14.5...20 325 KTC7-25H-20A 220<br />

KTC7-45H — High Interrupting Capacity<br />

2 5 5 7-1/2 20 25 18...25 416 KTC7-45H-25A 309<br />

2 5 10 10 25 30 23...32 585 KTC7-45H-32A 347<br />

KTC7-25S<br />

Description<br />

The KTC7 has a fixed magnetic trip set<br />

at 16…20x the maximum value of the<br />

current adjustment range (as opposed<br />

to the KTA7s magnetic trip of<br />

approximately 13x current adjustment<br />

range). KTC7 are typically used in<br />

applications where nuisance tripping<br />

might occur, as with some high<br />

efficiency motors.<br />

Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />

<strong>KT7</strong><br />

➊ Magnetic trip is fixed at 16…20x the maximum value of the current adjustment range.<br />

F6<br />

Discount Schedule A-1


<strong>Motor</strong> <strong>Circuit</strong> Controller<br />

Series KTC7<br />

Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />

KTC7 UL Ratings Application Chart<br />

<strong>Manual</strong> <strong>Motor</strong><br />

Starter<br />

Max. Short <strong>Circuit</strong><br />

Current [kA]<br />

<strong>Manual</strong> Controller for Group<br />

Installation ➊<br />

Max. Fuse<br />

or <strong>Circuit</strong><br />

Breaker<br />

Max. Short <strong>Circuit</strong><br />

Current [kA]<br />

➊ UL 508, CSA 22.2 No. 14 for group installation, in connection with short-circuit<br />

protection device.<br />

➋ UL 508 Part III.<br />

➌ UL 508 Part IV.<br />

➍ Type E applications require use of the <strong>KT7</strong>-xx-TE terminal adaptor on <strong>KT7</strong>s<br />

produced after July 16, 2001.<br />

➎ Requires lockable twist knob (<strong>KT7</strong>-KN or <strong>KT7</strong>-KRY) or lockable door coupling<br />

handle (<strong>KT7</strong>-HTN or <strong>KT7</strong>-HTRY). See page F14.<br />

<strong>Manual</strong> Controller<br />

as <strong>Motor</strong><br />

Disconnect ➋➎<br />

Max. Short <strong>Circuit</strong><br />

Current [kA]<br />

Suitable for Tap<br />

Conductor Protection<br />

Max. Short <strong>Circuit</strong><br />

Current [kA]<br />

Self-Protected Type E<br />

<strong>Manual</strong> Combination<br />

Controller ➌➍➎<br />

Max. Short <strong>Circuit</strong><br />

Current [kA]<br />

Device<br />

480V 600V 480V 600V 480V 600V 480Y/277V 600Y/347V 480Y/277V 600Y/347V<br />

KTC7-25S — Standard Interrupting Capacity<br />

KTC7-25S-0.16A 65 47 450 65 47 65 47 65 47 65 47<br />

KTC7-25S-0.25A 65 47 450 65 47 65 47 65 47 65 47<br />

KTC7-25S-0.4A 65 47 450 65 47 65 47 65 47 65 47<br />

KTC7-25S-0.63A 65 47 450 65 47 65 47 65 47 65 47<br />

KTC7-25S-1A 65 47 450 65 47 65 47 65 47 65 47<br />

KTC7-25S-1.6A 65 47 450 65 47 65 47 65 47 65 47<br />

KTC7-25S-2.5A 65 25 450 65 25 65 25 65 30 65 30<br />

KTC7-25S-4A 65 30 450 65 30 65 30 65 25 65 25<br />

KTC7-25S-6.3A 65 30 450 65 30 65 30 65 ~ 65 ~<br />

KTC7-25S-10A 30 30 450 30 30 30 30 30 ~ 30 ~<br />

KTC7-25S-16A 30 30 450 30 30 10 10 10 ~ 10 ~<br />

KTC7-25H — High Interrupting Capacity<br />

KTC7-25H-16A 65 30 450 65 30 65 30 65 30 65 30<br />

KTC7-25H-20A 30 30 450 30 30 65 30 30 ~ 30 ~<br />

KTC7-45H — High Interrupting Capacity<br />

KTC7-45H-25A 65 30 600 65 30 65 30 65 30 65 30<br />

KTC7-45H-32A 65 18 600 65 18 65 18 65 18 65 18<br />

It should be noted that the <strong>KT7</strong> <strong>Manual</strong> <strong>Motor</strong> <strong>Circuit</strong> Controller, when listed as a<br />

self-protected (Type E) device, is rated for Wye-connected power systems for<br />

voltages above 240 volts (i.e. 480Y / 277 volts common in the United States or<br />

600Y/ 347 volts common in Canada).<br />

F<br />

<strong>Motor</strong> <strong>Circuit</strong><br />

<strong>Controllers</strong><br />

<strong>KT7</strong><br />

Discount Schedule A-1<br />

F7


<strong>Motor</strong> <strong>Circuit</strong> Controller<br />

Series KTB7<br />

KTB7 Base Unit<br />

F<br />

<strong>Motor</strong> <strong>Circuit</strong><br />

<strong>Controllers</strong><br />

Typical<br />

Single<br />

Phase<br />

Maximum Horsepower<br />

Typical<br />

Three Phase [HP]<br />

Current<br />

Adjustment<br />

Range [A]<br />

Horsepower ratings shown in the table are for reference only.<br />

The final selection of the manual starter depends on the actual<br />

motor full load current and service factor.<br />

• For motor with service factor less than 1.15. Use motor nameplate full load<br />

current times 0.9 and choose the motor starter with the appropriate current<br />

range. Example: <strong>Motor</strong> F.L.C. = 4.2A; S.F. = 1.0. – (4.2A x 0.9 = 3.78A).<br />

Select Catalog Number KTA7-25S-4.0A.<br />

Magnetic<br />

Release<br />

Response<br />

Current [A] Catalog Number Price<br />

115V 230V 200V 230V 460V 575V<br />

KTB7-25S — Standard Interrupting Capacity<br />

~ ~ ~ ~ ~ ~ 0.16 3.3 KTB7-25S-0.16A 133<br />

~ ~ ~ ~ ~ ~ 0.25 5.2 KTB7-25S-0.25A 133<br />

~ ~ ~ ~ ~ ~ 0.40 8.2 KTB7-25S-0.4A 133<br />

~ ~ ~ ~ ~ ~ 0.63 13 KTB7-25S-0.63A 154<br />

~ ~ ~ ~ 1/2 3/4 1.0 21 KTB7-25S-1A 154<br />

~ 1/10 ~ ~ 1 1 1.6 33 KTB7-25S-1.6A 154<br />

1/10 1/6 1/2 3/4 1-1/2 2 2.5 52 KTB7-25S-2.5A 154<br />

KTB7-25H — High Interrupting Capacity<br />

1/10 1/6 1/2 3/4 1-1/2 2 2.5 33 KTB7-25H-2.5A 193<br />

1/4 3/4 1-1/2 2 5 5 4 52 KTB7-25H-4A 193<br />

1/2 1-1/2 3 3 7-1/2 10 6.3 82 KTB7-25H-6.3A 193<br />

1 3 3 5 10 15 10 130 KTB7-25H-10A 220<br />

1-1/2 3 5 7-1/2 15 20 16 208 KTB7-25H-16A 220<br />

2 3 7-1/2 7-1/2 15 20 25 325 KTB7-25H-25A 220<br />

KTB7-45H — High Interrupting Capacity<br />

2 5 5 7-1/2 20 25 25 325 KTB7-45H-25A 309<br />

2 5 10 10 25 30 32 416 KTB7-45H-32A 347<br />

3 7-1/2 15 15 30 40 45 585 KTB7-45H-45A 347<br />

KTB7-25S<br />

Description<br />

The KTB7 is designed without a<br />

thermal trip element (i.e., current<br />

adjustment range). It should be<br />

selected for applications where a<br />

separate motor overload protection<br />

device is used. Magnetic trip is the<br />

same as the KTA7 (approximately 13x<br />

operational current).<br />

Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />

<strong>KT7</strong><br />

F8<br />

Discount Schedule A-1


<strong>Motor</strong> <strong>Circuit</strong> Controller<br />

Series KTB7<br />

Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />

KTB7 UL Ratings Application Chart<br />

Device<br />

<strong>Manual</strong> <strong>Motor</strong><br />

Starter<br />

Max. Short <strong>Circuit</strong><br />

Current [kA]<br />

<strong>Manual</strong> Controller for Group<br />

Installation ➊<br />

Max. Fuse<br />

or <strong>Circuit</strong><br />

Breaker<br />

Max. Short <strong>Circuit</strong><br />

Current [kA]<br />

➊ UL 508, CSA 22.2 No. 14 for group installation, in connection with short-circuit<br />

protection device.<br />

➋ UL 508 Part III.<br />

<strong>Manual</strong> Controller<br />

as <strong>Motor</strong><br />

Disconnect ➋<br />

Max. Short <strong>Circuit</strong><br />

Current [kA]<br />

480V 600V 480V 600V 480V 600V<br />

KTA7-25S — Standard Interrupting Capacity<br />

KTB7-25S-0.16A 65 47 450 65 47 65 47<br />

KTB7-25S-0.25A 65 47 450 65 47 65 47<br />

KTB7-25S-0.4A 65 47 450 65 47 65 47<br />

KTB7-25S-0.63A 65 47 450 65 47 65 47<br />

KTB7-25S-1A 65 47 450 65 47 65 47<br />

KTB7-25S-1.6A 65 47 450 65 47 65 47<br />

KTB7-25S-2.5A 65 30 450 65 30 65 30<br />

KTA7-25H — High Interrupting Capacity<br />

KTB7-25H-2.5A 65 30 450 65 30 65 30<br />

KTB7-25H-4A 65 30 450 65 30 65 30<br />

KTB7-25H-6.3A 65 30 450 65 30 65 30<br />

KTB7-25H-10A 65 30 450 65 30 65 30<br />

KTB7-25H-16A 65 30 450 65 30 65 30<br />

KTB7-25H-25A 30 30 450 30 30 30 30<br />

KTA7-45H — High Interrupting Capacity<br />

KTB7-45H-25A 65 30 600 65 30 65 30<br />

KTB7-45H-32A 65 30 600 65 30 65 30<br />

KTB7-45H-45A 65 18 600 65 18 65 18<br />

F<br />

<strong>Motor</strong> <strong>Circuit</strong><br />

<strong>Controllers</strong><br />

<strong>KT7</strong><br />

Discount Schedule A-1<br />

F9


Accessories<br />

Series <strong>KT7</strong><br />

Accessories for <strong>KT7</strong><br />

F<br />

<strong>Motor</strong> <strong>Circuit</strong><br />

<strong>Controllers</strong><br />

➊ X=Contact Closed<br />

O=Contact Open<br />

➋<br />

Accessory<br />

Description<br />

Front-Mounted<br />

Auxiliary Contact<br />

• 1-pole or 2-pole<br />

• No additional<br />

space required<br />

Right<br />

Side-Mounted<br />

Auxiliary Contact<br />

• 2-pole<br />

• Adds 9 mm to<br />

the width of the<br />

device<br />

Operator Position ➊<br />

OFF ON Tripped<br />

Type<br />

Connection Diagram and<br />

Terminal Markings ➋<br />

For Use<br />

With Catalog Number Price<br />

O X O 1 NO All <strong>KT7</strong>s <strong>KT7</strong>-PE1-10 16<br />

X O X 1 NC All <strong>KT7</strong>s <strong>KT7</strong>-PE1-01 13<br />

O X O 1 NO<br />

X O X 1 NC<br />

O X O 1 NO<br />

O X O 1 NO<br />

X O X 1 NC<br />

X O X 1 NC<br />

O X O 1 NO<br />

O X O 1 NO<br />

X O X 1 NC<br />

X O X 1 NC<br />

O X O 1 NO<br />

X O X 1 NC<br />

All <strong>KT7</strong>s <strong>KT7</strong>-PE1-11 19<br />

All <strong>KT7</strong>s <strong>KT7</strong>-PE1-20 19<br />

All <strong>KT7</strong>s <strong>KT7</strong>-PE1-02 19<br />

All <strong>KT7</strong>s <strong>KT7</strong>-PA1-20 29<br />

All <strong>KT7</strong>s <strong>KT7</strong>-PA1-02 29<br />

All <strong>KT7</strong>s <strong>KT7</strong>-PA1-11 29<br />

Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />

<strong>KT7</strong><br />

F10<br />

Discount Schedule A-1


Accessories<br />

Series <strong>KT7</strong><br />

Accessories for <strong>KT7</strong><br />

Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />

➊ X=Contact Closed<br />

O=Contact Open<br />

➋<br />

Accessory<br />

Description<br />

Front-Mounted<br />

Trip Contact<br />

• 2-pole<br />

• Indicates<br />

tripping of<br />

device<br />

• No additional<br />

space required<br />

Right<br />

Side-Mounted<br />

Trip Contact<br />

• 2-pole<br />

• Indicates<br />

tripping of<br />

motor protector<br />

• Adds 9 mm to<br />

the width of the<br />

device<br />

Operator Position ➊<br />

OFF ON Tripped<br />

Type<br />

O X O 1 NO<br />

O O X<br />

NO Trip<br />

(Short-<strong>Circuit</strong> &<br />

Overload)<br />

X O X 1 NC<br />

O O X<br />

O O X<br />

O O X<br />

O O X<br />

X X O<br />

X X O<br />

O O X<br />

X X O<br />

X X O<br />

O O X<br />

X X O<br />

NO Trip<br />

(Short-<strong>Circuit</strong> &<br />

Overload)<br />

NO Trip<br />

(Short-<strong>Circuit</strong> &<br />

Overload)<br />

NO Trip<br />

(Short-<strong>Circuit</strong>)<br />

NO Trip<br />

(Short-<strong>Circuit</strong> &<br />

Overload)<br />

NC Trip<br />

(Short-<strong>Circuit</strong>)<br />

NC Trip<br />

(Short-<strong>Circuit</strong> &<br />

Overload)<br />

NO Trip<br />

(Short-<strong>Circuit</strong>)<br />

NC Trip<br />

(Short-<strong>Circuit</strong> &<br />

Overload)<br />

NC Trip<br />

(Short-<strong>Circuit</strong>)<br />

NO Trip<br />

(Short-<strong>Circuit</strong>)<br />

NC Trip<br />

(Short-<strong>Circuit</strong>)<br />

Connection Diagram and<br />

Terminal Markings ➋<br />

For Use<br />

With Catalog Number Price<br />

All <strong>KT7</strong>s <strong>KT7</strong>-PEF1-S10/N10 29<br />

All <strong>KT7</strong>s <strong>KT7</strong>-PEF1-S10/N01 29<br />

All <strong>KT7</strong>s <strong>KT7</strong>-PAF1-S10/M10 38<br />

All <strong>KT7</strong>s <strong>KT7</strong>-PAF1-S10/M01 38<br />

All <strong>KT7</strong>s <strong>KT7</strong>-PAF1-S01/M10 38<br />

All <strong>KT7</strong>s <strong>KT7</strong>-PAF1-S01/M01 38<br />

All <strong>KT7</strong>s <strong>KT7</strong>-PAF1-M11 38<br />

F<br />

<strong>Motor</strong> <strong>Circuit</strong><br />

<strong>Controllers</strong><br />

<strong>KT7</strong><br />

Discount Schedule A-1<br />

F11


Accessories<br />

Series KT3-100<br />

Accessories for KTA3-100<br />

F<br />

<strong>Motor</strong> <strong>Circuit</strong><br />

<strong>Controllers</strong><br />

Accessory<br />

➊ X=Contact Closed<br />

O=Contact Open<br />

➋<br />

Description<br />

Front-Mounted<br />

Auxiliary Contact<br />

• Internal<br />

• 2-pole<br />

Front Mounted<br />

Trip Indicating<br />

Auxiliary Contact<br />

• Internal<br />

• 2-pole<br />

Operator Position<br />

OFF ON Tripped<br />

Type<br />

O X O NO<br />

O X O NO<br />

X O X NC<br />

X O X NC<br />

O O X NO<br />

X O X NC<br />

O O X<br />

O O X<br />

X X O<br />

X X O<br />

X X O<br />

O O X<br />

O O X<br />

X X O<br />

NO Trip<br />

(Overload)<br />

NO Trip<br />

(Short-<strong>Circuit</strong>)<br />

NC Trip<br />

(Overload)<br />

NC Trip<br />

(Short-<strong>Circuit</strong>)<br />

NC Trip<br />

(Overload)<br />

NO Trip<br />

(Short-<strong>Circuit</strong>)<br />

NO Trip<br />

(Overload)<br />

NC Trip<br />

(Short-<strong>Circuit</strong>)<br />

Connection Diagram and<br />

Terminal Markings ➋<br />

For Use<br />

With Catalog Number Price<br />

KT3-100 KT3-100-PE-20 20<br />

KT3-100 KT3-100-PE-02 20<br />

KT3-100 KT3-100-PE-11 20<br />

KT3-100 KT3-100-PF-20 38<br />

KT3-100 KT3-100-PF-02 38<br />

KT3-100 KT3-100-PF1-11 38<br />

KT3-100 KT3-100-PF2-11 38<br />

Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />

<strong>KT7</strong><br />

F12<br />

Discount Schedule A-1


Accessories<br />

Series KTA3-100<br />

Accessories for KTA3-100<br />

Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />

Accessory<br />

Description<br />

Undervoltage Trip<br />

• Internal, front mounted<br />

• Integrated short-circuit trip<br />

integration<br />

• Automatically trips motor<br />

protector when voltage falls<br />

below 35…70%<br />

Shunt Trip Unit<br />

• Internal, front mounted<br />

• Integrated short-circuit trip<br />

integration<br />

• Trips motor protector when<br />

voltage is applied remotely<br />

Connection<br />

Diagram ➊<br />

◗<br />

For Use<br />

With<br />

KTA3-100<br />

KTA3-100<br />

AC Coil Voltage<br />

50 HZ 60 HZ<br />

➊<br />

Catalog Number<br />

24V 28V KT3-100-UA-28V<br />

110V 127V KT3-100-UA-127V<br />

220...230V ~ KT3-100-UA-230V<br />

240V 277V KT3-100-UA-277V<br />

380V 400V KT3-100-UA-400V<br />

415V 480V KT3-100-UA-480V<br />

500V 575V KT3-100-UA-575V<br />

24V 28V KT3-100-<strong>AA</strong>-28V<br />

110V 127V KT3-100-<strong>AA</strong>-127V<br />

220...230V ~ KT3-100-<strong>AA</strong>-230V<br />

240V 277V KT3-100-<strong>AA</strong>-277V<br />

380V 450V KT3-100-<strong>AA</strong>-450V<br />

415V 480V KT3-100-<strong>AA</strong>-480V<br />

500V 575V KT3-100-<strong>AA</strong>-575V<br />

Price<br />

62<br />

62<br />

F<br />

<strong>Motor</strong> <strong>Circuit</strong><br />

<strong>Controllers</strong><br />

➊ Special order on these items.<br />

KTA3<br />

Discount Schedule A-1<br />

F13


Accessories<br />

Series <strong>KT7</strong><br />

Accessories for <strong>KT7</strong><br />

F<br />

<strong>Motor</strong> <strong>Circuit</strong><br />

<strong>Controllers</strong><br />

➊<br />

Accessory<br />

Description<br />

Undervoltage Trip<br />

• Left-side mounted<br />

• Adds 18 mm to the width<br />

of the <strong>KT7</strong> device<br />

• Automatically trips motor<br />

protector when voltage<br />

falls below 35…70%<br />

Connection<br />

Diagram ➊<br />

For Use<br />

With<br />

All <strong>KT7</strong>s<br />

AC Coil Voltage<br />

50 HZ 60 HZ Catalog Number<br />

12V 14V <strong>KT7</strong>-UA-14V<br />

21V 24V <strong>KT7</strong>-UA-24V<br />

24V 28V <strong>KT7</strong>-UA-28V<br />

42V 48V <strong>KT7</strong>-UA-48V<br />

105V 120V <strong>KT7</strong>-UA-120V<br />

110V 127V <strong>KT7</strong>-UA-127V<br />

220...230V<br />

<strong>KT7</strong>-UA-230V<br />

240...260V <strong>KT7</strong>-UA-240V<br />

240V 277V <strong>KT7</strong>-UA-277V<br />

380V 460V <strong>KT7</strong>-UA-460V<br />

415V 480V <strong>KT7</strong>-UA-480V<br />

520V 600V <strong>KT7</strong>-UA-600V<br />

Price<br />

For Use<br />

With DC Coil Voltage Catalog Number Price<br />

9V DC<br />

<strong>KT7</strong>-UA-9D<br />

12V DC<br />

<strong>KT7</strong>-UA-12D<br />

24V DC<br />

<strong>KT7</strong>-UA-24D<br />

36V DC<br />

<strong>KT7</strong>-UA-36D<br />

All <strong>KT7</strong>s<br />

48V DC<br />

<strong>KT7</strong>-UA-48D<br />

68<br />

60V DC<br />

<strong>KT7</strong>-UA-60D<br />

64V DC<br />

<strong>KT7</strong>-UA-64D<br />

72V DC<br />

<strong>KT7</strong>-UA-72D<br />

80V DC<br />

<strong>KT7</strong>-UA-80D<br />

68<br />

Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />

<strong>KT7</strong><br />

F14<br />

Discount Schedule A-1


Accessories<br />

Series <strong>KT7</strong><br />

Accessories for <strong>KT7</strong><br />

Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />

➊<br />

Accessory<br />

Description<br />

Shunt Trip<br />

• Left-side mounted<br />

• Adds 18 mm to the width of<br />

the <strong>KT7</strong> device<br />

• Trips motor protector when<br />

voltage is applied remotely<br />

Connection<br />

Diagram ➊<br />

For Use<br />

With<br />

All <strong>KT7</strong>s<br />

AC Coil Voltage<br />

50 HZ 60 HZ Catalog Number<br />

12V 14V <strong>KT7</strong>-<strong>AA</strong>-14V<br />

21V 24V <strong>KT7</strong>-<strong>AA</strong>-24V<br />

24V 28V <strong>KT7</strong>-<strong>AA</strong>-28V<br />

42V 48V <strong>KT7</strong>-<strong>AA</strong>-48V<br />

105V 120V <strong>KT7</strong>-<strong>AA</strong>-120V<br />

110V 127V <strong>KT7</strong>-<strong>AA</strong>-127V<br />

220...230V<br />

<strong>KT7</strong>-<strong>AA</strong>-230V<br />

240...260V <strong>KT7</strong>-<strong>AA</strong>-260V<br />

240V 277V <strong>KT7</strong>-<strong>AA</strong>-277V<br />

380V 460V <strong>KT7</strong>-<strong>AA</strong>-460V<br />

415V 480V <strong>KT7</strong>-<strong>AA</strong>-480V<br />

520V 600V <strong>KT7</strong>-<strong>AA</strong>-600V<br />

Price<br />

For Use<br />

With DC Coil Voltage Catalog Number Price<br />

9V DC<br />

<strong>KT7</strong>-<strong>AA</strong>-9D<br />

12V DC<br />

<strong>KT7</strong>-<strong>AA</strong>-12D<br />

24V DC<br />

<strong>KT7</strong>-<strong>AA</strong>-24D<br />

36V DC<br />

<strong>KT7</strong>-<strong>AA</strong>-36D<br />

48V DC<br />

<strong>KT7</strong>-<strong>AA</strong>-48D<br />

60V DC<br />

<strong>KT7</strong>-<strong>AA</strong>-60D<br />

64V DC<br />

<strong>KT7</strong>-<strong>AA</strong>-64D<br />

All <strong>KT7</strong>s<br />

72V DC<br />

<strong>KT7</strong>-<strong>AA</strong>-72D<br />

68<br />

80V DC<br />

<strong>KT7</strong>-<strong>AA</strong>-80D<br />

110V DC <strong>KT7</strong>-<strong>AA</strong>-110D<br />

115V DC <strong>KT7</strong>-<strong>AA</strong>-115D<br />

125V DC <strong>KT7</strong>-<strong>AA</strong>-125D<br />

220V DC <strong>KT7</strong>-<strong>AA</strong>-220D<br />

230V DC <strong>KT7</strong>-<strong>AA</strong>-230D<br />

250V DC <strong>KT7</strong>-<strong>AA</strong>-250D<br />

68<br />

F<br />

<strong>Motor</strong> <strong>Circuit</strong><br />

<strong>Controllers</strong><br />

<strong>KT7</strong><br />

Discount Schedule A-1<br />

F15


Accessories<br />

Series <strong>KT7</strong> & KT3-100<br />

F<br />

<strong>Motor</strong> <strong>Circuit</strong><br />

<strong>Controllers</strong><br />

<strong>KT7</strong><br />

Accessories for <strong>KT7</strong> and KTA3<br />

Accessory Description Color For Use With<br />

Lockable Twist Knob<br />

• For 1 padlock 4...8 mm (5/16”) dia. shackle<br />

• Can be locked in OFF position<br />

Padlockable Operating Knob<br />

• Accepts 8 mm (5/16”) padlock — Up to three padlocks<br />

• Permits padlocking in the OFF position<br />

Door Coupling Handle ➊<br />

• For 3 padlocks 4...8 mm (5/16”) in diameter<br />

• NEMA Type 3 / 3R / 4 / 4X / 12 and IP66 Protection<br />

• Interlock override capability<br />

• Can be modified for locking in ON position<br />

• Ships with coupling — order extension shaft and legend<br />

plate separately<br />

• See Technical Section for mounting depth information<br />

Extension Shaft<br />

• Cut to required length for mounting depth (adapter-door)<br />

• See Technical Section for mounting depth information<br />

Terminal Adapter for Type E Applications ➋<br />

• Required on all <strong>KT7</strong>s used in UL Type E applications<br />

• May not be used with Bus Bars<br />

Legend Plate<br />

• Marking: “Haupschalter” and “Main Switch” (Black/Gray)<br />

• Marking: “Not-Aus” and “Emergency Off” (Black/Yellow)<br />

Locking Tag<br />

• Padlock attachment to the lockable handles<br />

• Up to three padlocks 4...8 mm (5/16”) shackle<br />

Anti-Tamper Shield<br />

• Provides protection against inadvertent adjustment of the<br />

current setting<br />

• 10 pieces per package (price per piece)<br />

Screw Adaptor<br />

• For screw fixing of <strong>KT7</strong> <strong>Motor</strong> <strong>Circuit</strong> Controller<br />

• 10 pieces per package (price per piece)<br />

➊ Door Coupling Handles [Cat.# KT3-100-HTN or KT3-100-HTRY] are available for<br />

KTA3-100 when used in manual motor starter applications. KTA3-100 is not rated<br />

as a UL Type E disconnect. Contact your Sprecher + Schuh representative.<br />

➋ Terminal Adaptors are supplied as standard on enclosed <strong>KT7</strong> and CX7 starters, as<br />

well as, CL4, CL7 and CK7 assembled products, assuring they can be used in<br />

Type E applications.<br />

Catalog<br />

Number<br />

Price<br />

Black All <strong>KT7</strong>s <strong>KT7</strong>-KN 6<br />

Red/Yellow<br />

<strong>KT7</strong>-25<br />

<strong>KT7</strong>-45<br />

<strong>KT7</strong>-KRY<br />

<strong>KT7</strong>-45-KRY<br />

Black KTA3-100 KT3-100-KN 16<br />

Red/Yellow KTA3-100 KT3-100-KRY 16<br />

Gray/Black All <strong>KT7</strong>s ➊ <strong>KT7</strong>-HTN 71<br />

Red/Yellow All <strong>KT7</strong>s ➊ <strong>KT7</strong>-HTRY 86<br />

<strong>KT7</strong>-HTN<br />

<strong>KT7</strong>-HTRY<br />

KTA3-100-HTN<br />

KTA3-100-HTRY<br />

All <strong>KT7</strong>-25<br />

All <strong>KT7</strong>-45<br />

<strong>KT7</strong>-HTN<br />

<strong>KT7</strong>-HTRY<br />

<strong>KT7</strong>-KN<br />

<strong>KT7</strong>-KRY<br />

<strong>KT7</strong>-45-KRY<br />

9<br />

<strong>KT7</strong>-HT 14<br />

<strong>KT7</strong>-25-TE<br />

<strong>KT7</strong>-45-TE<br />

<strong>KT7</strong>-HTFCN<br />

<strong>KT7</strong>-HTFCRY<br />

5<br />

5<br />

5<br />

5<br />

<strong>KT7</strong>-DS 23<br />

<strong>KT7</strong>-25 <strong>KT7</strong>-25-CA 19<br />

<strong>KT7</strong>-25<br />

<strong>KT7</strong>-45<br />

<strong>KT7</strong>-45-AS 10<br />

Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />

F16<br />

Discount Schedule A-1


Accessories<br />

Series KF7<br />

Connecting Modules (for connecting <strong>KT7</strong> to CA4 contactors or CA7 AC coil contactors) ➊<br />

Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />

Module<br />

Connecting Modules (for connecting <strong>KT7</strong> to CA7 two winding DC coil contactors)<br />

Module<br />

Mounting Modules<br />

Module<br />

<strong>KT7</strong>-25S-PNC23<br />

<strong>KT7</strong>-25S-PSC23<br />

Description<br />

Connecting Modules (forms Ecombo Starter) - ➊<br />

• Provides electrical and mechanical interconnection<br />

of <strong>KT7</strong> and CA4 (with AC or DC coils) or CA7 (with AC<br />

coils).<br />

• Suitable for reversing and wye-delta kits<br />

• Ecombo starter (with <strong>KT7</strong>-25) mounts on a single<br />

DIN-rail (<strong>KT7</strong> mounts on DIN-rail)<br />

• Ecombo starter (with <strong>KT7</strong>-45) can be mounted on two<br />

DIN-rails or on Mounting Modules (see selection table<br />

below)<br />

Description<br />

Connecting Modules<br />

• Provides electrical interconnection<br />

of <strong>KT7</strong> and CA7-(Y) two winding DC<br />

contactors<br />

• Coil Module extends A1/A2 terminals<br />

forward to facilitate wiring (required)<br />

• Contactor and motor protector must be<br />

mounted on two DIN-rails or on<br />

Mounting Modules (see selection table<br />

below)<br />

Description<br />

Mounting Module -<br />

Requires Connecting Module from tables above<br />

• Provides support for <strong>KT7</strong> + CA7 or CA4<br />

• Top rail is specifically designed for <strong>KT7</strong><br />

• Bottom rail is movable for easy assembly and<br />

disassembly<br />

• Complete unit mounts to two 35mm DIN-rails<br />

or one 70mm DIN-rail or screw mounts<br />

• 228 mm high<br />

Mounting Module -<br />

See Section D for Connecting Modules<br />

• Provides support for <strong>KT7</strong> + PCS or PDS<br />

Softstarter or CA7 + PCS or PDS Softstarter<br />

• Top rail is specifically designed for <strong>KT7</strong><br />

• Bottom rail is movable for easy assembly and<br />

disassembly<br />

• Complete unit mounts to two 35mm DIN-rails<br />

or one 70mm DIN-rail or screw mounts<br />

• 283 mm high<br />

For<br />

Connecting. . .<br />

For<br />

Connecting. . .<br />

To<br />

Contactor. . . Catalog Number ➊ Price<br />

<strong>KT7</strong>-25S CA4-9...12 <strong>KT7</strong>-25S-PEM12 24<br />

<strong>KT7</strong>-25S CA7-9...23 <strong>KT7</strong>-25S-PEC23 29<br />

<strong>KT7</strong>-25H CA7-9...23 <strong>KT7</strong>-25H-PEC23 29<br />

<strong>KT7</strong>-25H CA7-30...37 <strong>KT7</strong>-25H-PNC37 29<br />

<strong>KT7</strong>-45H CA7-30...37 <strong>KT7</strong>-45H-PNC37 29<br />

<strong>KT7</strong>-45H CA7-43 <strong>KT7</strong>-45H-PNC43 29<br />

To<br />

Contactor. . .<br />

Use<br />

Connector. . . ➊<br />

Price<br />

<strong>KT7</strong>-25S CA7-9Y...23Y <strong>KT7</strong>-25S-PNC23 29<br />

<strong>KT7</strong>-25H CA7-9Y...23Y <strong>KT7</strong>-25H-PNC23 29<br />

<strong>KT7</strong>-25H CA7-30Y...37Y <strong>KT7</strong>-25H-PNC37 29<br />

<strong>KT7</strong>-45H CA7-30Y...37Y <strong>KT7</strong>-45H-PNC37 29<br />

<strong>KT7</strong>-45H CA7-43Y <strong>KT7</strong>-45H-PNC43 29<br />

Width<br />

(mm) Catalog Number Price<br />

45 <strong>KT7</strong>-WS45RR 15<br />

54 <strong>KT7</strong>-WS54RR 17<br />

45 <strong>KT7</strong>-WM45RR 16<br />

54 <strong>KT7</strong>-WM54RR 18<br />

With<br />

Coil Module. . .<br />

Price<br />

<strong>KT7</strong>-25S-PSC23 14<br />

<strong>KT7</strong>-45H-PSC43 14<br />

➊ cURus Approved (File # E33916).<br />

F<br />

<strong>Motor</strong> <strong>Circuit</strong><br />

<strong>Controllers</strong><br />

<strong>KT7</strong><br />

Discount Schedule A-1<br />

F17


Accessories<br />

Series <strong>KT7</strong><br />

F<br />

<strong>Motor</strong> <strong>Circuit</strong><br />

<strong>Controllers</strong><br />

<strong>KT7</strong><br />

Compact Busbar System for <strong>KT7</strong>-25 and <strong>KT7</strong>-45 ➊➋<br />

A2E<br />

Accessory Description For Use With Catalog Number Price<br />

A3E<br />

Top view<br />

➊ UL Approved (File #E33916); CSA Approved (File #13908).<br />

➋ Compact busbar may not be applied with <strong>KT7</strong>-25-TE or <strong>KT7</strong>-45-TE Terminal<br />

Adaptors. Either Terminal Adaptors or Bus Bar may be used, not both.<br />

➌ <strong>KT7</strong>-25S and <strong>KT7</strong>-25H may not be combined without <strong>KT7</strong>-25-DB25H-54.<br />

Compact Busbar — 45 mm Spacing (Rated 63 A)<br />

• For use with front-mounted auxiliary contact<br />

Connects 2-<strong>KT7</strong>s<br />

Connects 3-<strong>KT7</strong>s<br />

Connects 4-<strong>KT7</strong>s<br />

Connects 5-<strong>KT7</strong>s<br />

Compact Busbar — 54 mm Spacing (Rated 63 A)<br />

• For use with side-mounted auxiliary contact<br />

Connects 2-<strong>KT7</strong>s<br />

Connects 3-<strong>KT7</strong>s<br />

Connects 4-<strong>KT7</strong>s<br />

Connects 5-<strong>KT7</strong>s<br />

Compact Busbar — 63 mm Spacing (Rated 63 A)<br />

• For use with side-mounted undervoltage trip or shunt trip<br />

Connects 2-<strong>KT7</strong>s<br />

Connects 3-<strong>KT7</strong>s<br />

Connects 4-<strong>KT7</strong>s<br />

Connects 5-<strong>KT7</strong>s<br />

Compact Busbar — 54mm Spacing (Rated 120 A)<br />

• For use with front-mounted auxiliary contact<br />

Connects 2-<strong>KT7</strong>s<br />

Connects 3-<strong>KT7</strong>s<br />

Connects 4-<strong>KT7</strong>s<br />

Compact Busbar — 63 mm Spacing (Rated 120 A)<br />

• For use with side-mounted auxiliary contact<br />

Connects 2-<strong>KT7</strong>s<br />

Connects 3-<strong>KT7</strong>s<br />

Connects 4-<strong>KT7</strong>s<br />

Jumper for <strong>KT7</strong>-25H to <strong>KT7</strong>-25S (Rated 63 A)<br />

• Accommodates difference in depth from <strong>KT7</strong>-25H to<br />

<strong>KT7</strong>-25S<br />

• Can be used with all other commoning links<br />

• 54 mm spacing<br />

Connects 2-<strong>KT7</strong>s<br />

Supply Block and Terminal<br />

• For power connection to Compact Busbar — 600V,<br />

<strong>KT7</strong>-25…63A max. / <strong>KT7</strong>-45…120A maximum<br />

• Top feed — overlaps commoning link<br />

• Meets requirements for terminal spacing from source<br />

in Type E applications<br />

Terminal Cover<br />

• For covering of unused connection terminals<br />

• IP2X finger protection<br />

<strong>KT7</strong>-25S or<br />

<strong>KT7</strong>-25H ➌<br />

(may not be<br />

combined)<br />

<strong>KT7</strong>-25S or<br />

<strong>KT7</strong>-25H ➌<br />

(may not be<br />

combined)<br />

<strong>KT7</strong>-25S or<br />

<strong>KT7</strong>-25H ➌<br />

<strong>KT7</strong>-45H<br />

<strong>KT7</strong>-45H<br />

<strong>KT7</strong>-25S to<br />

<strong>KT7</strong>-25H ➌<br />

<strong>KT7</strong>-25S or<br />

<strong>KT7</strong>-25H ➌<br />

<strong>KT7</strong>-25-DB-45-2<br />

<strong>KT7</strong>-25-DB-45-3<br />

<strong>KT7</strong>-25-DB-45-4<br />

<strong>KT7</strong>-25-DB-45-5<br />

<strong>KT7</strong>-25-DB-54-2<br />

<strong>KT7</strong>-25-DB-54-3<br />

<strong>KT7</strong>-25-DB-54-4<br />

<strong>KT7</strong>-25-DB-54-5<br />

<strong>KT7</strong>-25-DB-63-2<br />

<strong>KT7</strong>-25-DB-63-3<br />

<strong>KT7</strong>-25-DB-63-4<br />

<strong>KT7</strong>-25-DB-63-5<br />

<strong>KT7</strong>-45-DB-54-2<br />

<strong>KT7</strong>-45-DB-54-3<br />

<strong>KT7</strong>-45-DB-54-4<br />

<strong>KT7</strong>-45-DB-63-2<br />

<strong>KT7</strong>-45-DB-63-3<br />

<strong>KT7</strong>-45-DB-63-4<br />

28<br />

32<br />

36<br />

40<br />

28<br />

32<br />

36<br />

40<br />

28<br />

32<br />

36<br />

40<br />

56<br />

64<br />

72<br />

56<br />

64<br />

72<br />

<strong>KT7</strong>-25-DB25H-54-2 40<br />

<strong>KT7</strong>-25-A2E 34<br />

<strong>KT7</strong>-25-A3E 27<br />

<strong>KT7</strong>-45H <strong>KT7</strong>-45-A3E 80<br />

<strong>KT7</strong>-25...<br />

<strong>KT7</strong>-45H<br />

<strong>KT7</strong>-25-DBA<br />

<strong>KT7</strong>-45-DBA<br />

4<br />

5<br />

Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />

F18<br />

Discount Schedule A-1


Accessories<br />

Series <strong>KT7</strong><br />

Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />

KF7 Fuse Holder to be used with <strong>KT7</strong> ➋<br />

Accessory<br />

Accessory<br />

Blown Fuse<br />

Indicator<br />

KF7 is Compatible with <strong>KT7</strong><br />

Compact Busbar<br />

Lockable in Open<br />

Position<br />

Connection<br />

Diagram Description Catalog Number Price<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

Description<br />

Auxiliary Contact for KF7 Fuse Holder<br />

(1 NO Late Make + NC Early Break)<br />

IEC/CE<br />

Approvals<br />

UL/CSA<br />

• NO Late Make, provides positive indication that power circuit is open<br />

• NC Early Break, provides capability for dropping out contactor before breaking<br />

current on fuse<br />

Catalog Number<br />

KF7 Fuse Holder, CC - 30A Yes Yes KF7-D3C-C30 38.00<br />

KF7 Fuse Holder, Midget - 30A Yes Yes KF7-D3M-C30 38.00<br />

KF7 Fuse Holder with Blown Fuse Indication, CC - 30A Yes Yes KF7-D3C-C30L 53.00<br />

KF7 Fuse Holder with Blown Fuse Indication, Midget - 30A Yes Yes KF7-D3M-C30L 53.00<br />

Connector to<br />

Contactor<br />

➊<br />

Price<br />

Applying KF7 with KTA7 <strong>Motor</strong> <strong>Circuit</strong><br />

<strong>Controllers</strong> and CA7 Contactors<br />

KF7 can be applied on the line side of a multiple<br />

small KTA7 motor circuit controller or a single KTA7<br />

controller and CA7 contactors to increase the shortcircuit<br />

protection of the group or a single branch<br />

circuit. KF7 is compatible with the <strong>KT7</strong> compact<br />

bus bars (as shown in Section F), which reduces<br />

the space requirement as well as installation time.<br />

Applying KF7 with CA7 Contactors<br />

KF7 can be applied on the line side of CA7<br />

contactors to increase the short-circuit withstand<br />

rating. The cUL withstand rating of CA7 when protected<br />

by Type”CC” fuses is increased to 100KAIC<br />

as shown on page A44. Similarly, when applying<br />

European Type “gG” fuses under CE rules, the<br />

withstand rating in combination with CA7 is also<br />

increased to 100 KAIC also shown on page A44.<br />

KF7-PE1-11 19.00<br />

F<br />

<strong>Motor</strong> <strong>Circuit</strong><br />

<strong>Controllers</strong><br />

➊ See “PNC” connections on pg. F17.<br />

➋ Connection diagrams on pg. F33.<br />

KF7<br />

Discount Schedule A-1<br />

F19


Technical Information<br />

Type 2 Coordination<br />

Type 2 Coordination per UL508E (Voltage: 480V, 60 HZ) ➊<br />

F<br />

<strong>Motor</strong> <strong>Circuit</strong><br />

<strong>Controllers</strong><br />

<strong>KT7</strong><br />

<strong>Motor</strong> Protector Catalog Number<br />

Definition of Type 2 short-circuit coordination per UL508E<br />

• The contactor or starter must not endanger persons or plant in the event of a<br />

short-circuit.<br />

• The contactor or starter must be suitable for continuous use.<br />

• No damage to the overload relay or other parts may occur with the exception of<br />

welding of the contactor or starter contacts if these can be easily separated<br />

without appreciable deformation (such as with a screwdriver).<br />

In the event of a short-circuit, fast-opening, strong current-limiting <strong>KT7</strong> motor<br />

protectors make it possible to build economical, fully short-circuit coordinated starter<br />

combinations in accordance with UL508E, Type 2 coordination.<br />

➊ The ratings in this table assume that the <strong>KT7</strong> and contactor are mounted<br />

separately and connected via cable.<br />

➋ Ratings apply to specified or larger contactor.<br />

Thermal Overload Release<br />

Setting Range [A]<br />

<strong>KT7</strong>-25S — Standard Interrupting Capacity<br />

Contactor Catalog<br />

Number ➋<br />

Short-<strong>Circuit</strong><br />

Current [kA]<br />

KTA7-25S-0.16A KTC7-25S-0.16A KTB7-25S-0.16A 0.10...0.16 CA7-9, CA4-9(12) 65<br />

KTA7-25S-0.25A KTC7-25S-0.25A KTB7-25S-0.25A 0.16...0.25 CA7-9, CA4-9(12) 65<br />

KTA7-25S-0.4A KTC7-25S-0.4A KTB7-25S-0.4A 0.25...0.40 CA7-9, CA4-9(12) 65<br />

KTA7-25S-0.63A KTC7-25S-0.63A KTB7-25S-0.63A 0.40...0.63 CA7-9, CA4-9(12) 65<br />

KTA7-25S-1A KTC7-25S-1A KTB7-25S-1A 0.63...1.0 CA7-9, CA4-9(12) 65<br />

KTA7-25S-1.6A KTC7-25S-1.6A KTB7-25S-1.6A 1.0...1.6 CA7-9, CA4-9(12) 65<br />

KTA7-25S-2.5A KTC7-25S-2.5A KTB7-25S-2.5A 1.6...2.5 CA7-9 50<br />

KTA7-25S-4A KTC7-25S-4A ~ 2.5...4.0 CA7-30 50<br />

KTA7-25S-6.3A KTC7-25S-6.3A ~ 4.0...6.3 CA7-30 50<br />

KTA7-25S-10A KTC7-25S-10A ~ 6.3...10.0 CA7-30 50<br />

KTA7-25S-16A KTC7-25S-16A ~ 10.0...16.0 CA7-30 10<br />

KTA7-25S-20A ~ ~ 14.5...20.0 CA7-30 10<br />

KTA7-25S-25A ~ ~ 18...25.0 CA7-30 10<br />

<strong>KT7</strong>-25H — High Interrupting Capacity<br />

KTA7-25H-2.5A ~ KTB7-25H-2.5A 1.6...2.5 CA7-9 65<br />

KTA7-25H-4A ~ KTB7-25H-4A 2.5...4.0 CA7-9 65<br />

KTA7-25H-6.3A ~ KTB7-25H-6.3A 4.0...6.3 CA7-9 65<br />

KTA7-25H-10A ~ KTB7-25H-10A 6.3...10.0 CA7-9 65<br />

KTA7-25H-16A KTC7-25H-16A KTB7-25H-16A 10.0...16.0 CA7-12 65<br />

KTA7-25H-20A KTC7-25H-20A ~ 14.5...20.0 CA7-23 65<br />

KTA7-25H-25A ~ KTB7-25H-25A 18.0...25.0 CA7-23 65<br />

<strong>KT7</strong>-45H — High Interrupting Capacity<br />

KTA7-45H-10A ~ ~ 6.3...10.0 CA7-9 65<br />

KTA7-45H-16A ~ ~ 10.0...16.0 CA7-12 65<br />

KTA7-45H-20A ~ ~ 14.5...20.0 CA7-16 65<br />

KTA7-45H-25A KTC7-45H-25A KTB7-45H-25A 18.0...25.0 CA7-23 65<br />

KTA7-45H-32A KTC7-45H-32A KTB7-45H-32A 23.0...32.0 CA7-30 65<br />

KTA7-45H-45A ~ KTB7-45H-45A 32.0...45.0 CA7-37 65<br />

KTA3-100 — High Interrupting Capacity<br />

KTA3-100-25A ~ ~ 16.0...25.0 CA7-16 65<br />

KTA3-100-40A ~ ~ 25.0...40.0 CA7-30 65<br />

KTA3-100-63A ~ ~ 40.0...63.0 CA7-43 42<br />

KTA3-100-90A ~ ~ 63.0...90.0 CA7-72 35<br />

Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />

F20<br />

Discount Schedule A-1


Technical Information<br />

Type 2 Coordination<br />

Type 2 Coordination per UL508E (Voltage: 600V, 60 HZ) ➊<br />

Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />

<strong>Motor</strong> Protector Catalog Number<br />

Definition of Type 2 short-circuit coordination per UL508E<br />

• The contactor or starter must not endanger persons or plant in the event of a<br />

short-circuit.<br />

• The contactor or starter must be suitable for continuous use.<br />

• No damage to the overload relay or other parts may occur with the exception of<br />

welding of the contactor or starter contacts if these can be easily separated<br />

without appreciable deformation (such as with a screwdriver).<br />

In the event of a short-circuit, fast-opening, strong current-limiting <strong>KT7</strong> motor<br />

protectors make it possible to build economical, fully short-circuit coordinated starter<br />

combinations in accordance with UL508E, Type 2 coordination.<br />

➊ The ratings in this table assume that the <strong>KT7</strong> and contactor are mounted<br />

separately and connected via cable.<br />

➋ Ratings apply to specified or larger contactor.<br />

Thermal Overload Release<br />

Setting Range [A]<br />

<strong>KT7</strong>-25S — Standard Interrupting Capacity<br />

Contactor Catalog<br />

Number ➋<br />

Short-<strong>Circuit</strong><br />

Current [kA]<br />

KTA7-25S-0.16A KTC7-25S-0.16A KTB7-25S-0.16A 0.10...0.16 CA7-9, CA4-9(12) 47<br />

KTA7-25S-0.25A KTC7-25S-0.25A KTB7-25S-0.25A 0.16...0.25 CA7-9, CA4-9(12) 47<br />

KTA7-25S-0.4A KTC7-25S-0.4A KTB7-25S-0.4A 0.25...0.40 CA7-9, CA4-9(12) 47<br />

KTA7-25S-0.63A KTC7-25S-0.63A KTB7-25S-0.63A 0.40...0.63 CA7-9, CA4-9(12) 47<br />

KTA7-25S-1A KTC7-25S-1A KTB7-25S-1A 0.63...1.0 CA7-9, CA4-9(12) 47<br />

KTA7-25S-1.6A KTC7-25S-1.6A KTB7-25S-1.6A 1.0...1.6 CA7-9, CA4-9(12) 47<br />

KTA7-25S-2.5A KTC7-25S-2.5A KTB7-25S-2.5A 1.6...2.5 CA7-16 10<br />

KTA7-25S-4A KTC7-25S-4A ~ 2.5...4.0 CA7-16 10<br />

KTA7-25S-6.3A KTC7-25S-6.3A ~ 4.0...6.3 CA7-23 5<br />

KTA7-25S-10A KTC7-25S-10A ~ 6.3...10.0 CA7-30 5<br />

KTA7-25S-16A KTC7-25S-16A ~ 10.0...16.0 CA7-30 5<br />

KTA7-25S-20A ~ ~ 14.5...20.0 CA7-30 5<br />

KTA7-25S-25A ~ ~ 18...25.0 CA7-30 5<br />

<strong>KT7</strong>-25H — High Interrupting Capacity<br />

KTA7-25H-2.5A ~ KTB7-25H-2.5A 1.6...2.5 CA7-9 30<br />

KTA7-25H-4A ~ KTB7-25H-4A 2.5...4.0 CA7-16 30<br />

KTA7-25H-6.3A ~ KTB7-25H-6.3A 4.0...6.3 CA7-23 30<br />

KTA7-25H-10A ~ KTB7-25H-10A 6.3...10.0 CA7-30 30<br />

KTA7-25H-16A KTC7-25H-16A KTB7-25H-16A 10.0...16.0 CA7-30 30<br />

KTA7-25H-20A KTC7-25H-20A ~ 14.5...20.0 CA7-30 5<br />

KTA7-25H-25A ~ KTB7-25H-25A 18.0...25.0 CA7-30 5<br />

<strong>KT7</strong>-45H — High Interrupting Capacity<br />

KTA7-45H-10A ~ ~ 6.3...10.0 CA7-30 30<br />

KTA7-45H-16A ~ ~ 10.0...16.0 CA7-30 30<br />

KTA7-45H-20A ~ ~ 14.5...20.0 CA7-30 30<br />

KTA7-45H-25A KTC7-45H-25A KTB7-45H-25A 18.0...25.0 CA7-30 30<br />

KTA7-45H-32A KTC7-45H-32A KTB7-45H-32A 23.0...32.0 CA7-30 30<br />

KTA7-45H-45A ~ KTB7-45H-45A 32.0...45.0 CA7-37 10<br />

KTA3-100 — High Interrupting Capacity<br />

KTA3-100-25A ~ ~ 16.0...25.0 CA7-16 43<br />

KTA3-100-40A ~ ~ 25.0...40.0 CA7-30 43<br />

KTA3-100-63A ~ ~ 40.0...63.0 CA7-43 18<br />

KTA3-100-90A ~ ~ 63.0...90.0 CA7-72 10<br />

F<br />

<strong>Motor</strong> <strong>Circuit</strong><br />

<strong>Controllers</strong><br />

<strong>KT7</strong><br />

Discount Schedule A-1<br />

F21


Technical Information<br />

<strong>KT7</strong> <strong>Motor</strong> <strong>Circuit</strong> Controller<br />

IEC Performance Data<br />

Catalog Number KTA7-25S...<br />

0.16A 0.25A 0.4A 0.63A 1A 1.6A 2.5A 4A 6.3A 10A 16A 20A 25A<br />

Rated Operational Current, I e<br />

[A] 0.16 0.25 0.4 0.63 1 1.6 2.5 4 6.3 10 16 20 25<br />

Magnetic Release Current [A] 2.1 3.3 5.2 8.2 13 21 33 52 82 130 208 260 325<br />

Switching of Standard<br />

Three-Phase <strong>Motor</strong>s<br />

AC-2, AC-3<br />

230/240V [kW] ~ ~ ~ 0.06/0.09 0.12 0.18/0.25 0.37 0.55/0.75 1.1/1.5 2.2 3.0/4.0 4.0/5.5 ~<br />

400/415V [kW] 0.02 0.06 0.09 0.12/0.18 0.25 0.37/0.55 0.75 1.1/1.5 2.2 3.0/4.0 5.5/7.5 7.5/10 11<br />

500V [kW] ~ ~ ~ 0.18 0.25/0.37 0.55/0.75 1.1 1.5/2.2 2.5/3.0 4.0/6.3 7.5/10 11 15<br />

690V [kW] ~ ~ ~ 0.25 0.37/0.55 0.75/1.1 1.8 2.2/3.0 4.0 5.5/7.5 11/13 15/17 18.5/22<br />

Back-up Fuses<br />

gG, gL, only if I cc<br />

>I cu<br />

230/240V [A] ➊ ➊ ➊ ➊ ➊ ➊ ➊ ➊ ➊ ➊ ➊ 100 100<br />

400/415V [A] ➊ ➊ ➊ ➊ ➊ ➊ ➊ ➊ ➊ ➊ 80 100 100<br />

440/460V [A] ➊ ➊ ➊ ➊ ➊ ➊ ➊ ➊ ➊ 63 63 80 80<br />

500V [A] ➊ ➊ ➊ ➊ ➊ ➊ ➊ ➊ ➊ 80 80 80 80<br />

690V [A] ➊ ➊ ➊ ➊ ➊ 16 20 35 50 50 63 63 63<br />

Ultimate Short-<strong>Circuit</strong><br />

Breaking Capacity<br />

I cu<br />

230/240V [kA] 100 100 100 100 100 100 100 100 100 100 100 50 50<br />

400/415V [kA] 100 100 100 100 100 100 100 100 100 100 65 50 15<br />

440/460V [kA] 100 100 100 100 100 100 100 100 100 50 10 6 6<br />

500V [kA] 100 100 100 100 100 100 100 100 100 50 10 6 6<br />

690V [kA] 100 100 100 100 100 8 8 8 4 4 3 3 3<br />

Rated Service Short-<strong>Circuit</strong><br />

Breaking Capacity<br />

I cs<br />

230/240V [kA] 100 100 100 100 100 100 100 100 100 100 100 50 50<br />

400/415V [kA] 100 100 100 100 100 100 100 100 100 100 50 15 15<br />

440/460V [kA] 100 100 100 100 100 100 100 100 100 50 6 6 6<br />

500V [kA] 100 100 100 100 100 100 100 100 100 50 6 6 6<br />

690V [kA] 100 100 100 100 100 8 8 8 4 4 3 3 3<br />

F<br />

<strong>Motor</strong> <strong>Circuit</strong><br />

<strong>Controllers</strong><br />

Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />

F22<br />

Discount Schedule A-1


Technical Information<br />

<strong>KT7</strong> <strong>Motor</strong> <strong>Circuit</strong> Controller<br />

Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />

IEC Performance Data<br />

Catalog Number KTA7-25H...<br />

Catalog Number KTA7-45H...<br />

2.5A 4A 6.3A 10A 16A 20A 25A 10A 16A 20A 25A 32A 45A<br />

Rated Operational Current, I e<br />

[A] 2.5 4 6.3 10 16 20 25 10 16 20 25 32 45<br />

Magnetic Release Current [A] 33 52 82 130 208 260 325 130 208 260 325 416 585<br />

Switching of Standard<br />

Three-Phase <strong>Motor</strong>s<br />

AC-2, AC-3<br />

230/240V [kW] 0.37 0.55/0.75 1.1/1.5 2.2 3.0/4.0 4.0/5.5 ~ 2.2 3.0/4.0 4.0/5.5 5.5/6.3 7.5 11/13<br />

400/415V [kW] 0.75 1.1/1.5 2.2 3.0/4.0 5.5/7.5 7.5/10 11 3.0/4.0 5.5/7.5 7.5/10 11 15 18.5/22<br />

500V [kW] 1.1 1.5/2.2 2.5/3.0 4.0/6.3 7.5/10 11 15 4.0/6.3 7.5/10 11 15 15/20 22/30<br />

690V [kW] 1.8 2.2/3.0 4.0 5.5/7.5 11/13 15/17 18.5/22 5.5/7.5 11/13 15/17 18.5/22 22/25 30/40<br />

Back-up Fuses<br />

gG, gL, only if I cc<br />

>I cu<br />

230/240V [A] ➊ ➊ ➊ ➊ ➊ ➊ ➊ ➊ ➊ ➊ ➊ ➊ ➊<br />

400/415V [A] ➊ ➊ ➊ ➊ ➊ 100 100 80 100 100 100 125 125<br />

440/460V [A] ➊ ➊ ➊ ➊ ➊ 100 100 80 100 100 100 125 125<br />

500V [A] ➊ ➊ ➊ ➊ 80 80 80 80 100 100 100 125 125<br />

690V [A] 20 35 50 50 63 63 63 63 80 80 80 100 100<br />

Ultimate Short-<strong>Circuit</strong><br />

Breaking Capacity<br />

I cu<br />

230/240V [kA] 100 100 100 100 100 100 100 100 100 100 100 100 100<br />

400/415V [kA] 100 100 100 100 100 65 65 65 65 65 65 65 65<br />

440/460V [kA] 100 100 100 100 50 65 65 65 65 65 65 65 50<br />

500V [kA] 100 100 100 100 50 50 50 50 50 50 50 50 50<br />

690V [kA] 10 10 10 6 6 6 6 10 10 10 10 10 10<br />

Rated Service Short-<strong>Circuit</strong><br />

Breaking Capacity<br />

I cs<br />

230/240V [kA] 100 100 100 100 100 100 100 100 100 100 100 100 100<br />

400/415V [kA] 100 100 100 100 50 25 50 50 50 50 50 50 50<br />

440/460V [kA] 100 100 100 100 50 25 25 50 50 50 50 50 50<br />

500V [kA] 100 100 100 100 50 25 25 50 50 50 50 50 50<br />

690V [kA] 10 10 10 6 4 4 4 10 10 10 10 6 6<br />

F<br />

<strong>Motor</strong> <strong>Circuit</strong><br />

<strong>Controllers</strong><br />

➊ No backup fuse required.<br />

<strong>KT7</strong><br />

Discount Schedule A-1<br />

F23


Technical Information<br />

<strong>KT7</strong> <strong>Motor</strong> <strong>Circuit</strong> Controller<br />

F<br />

<strong>Motor</strong> <strong>Circuit</strong><br />

<strong>Controllers</strong><br />

IEC Performance Data<br />

Catalog Number KTB7-25S...<br />

0.16A 0.25A 0.4A 0.63A 1A 1.6A 2.5A<br />

Rated Operational Current, I e<br />

[A] 0.16 0.25 0.4 0.63 1 1.6 2.5<br />

Magnetic Release Current [A] 2.1 3.3 5.2 8.2 13 21 32<br />

Switching of Standard<br />

Three-Phase <strong>Motor</strong>s<br />

AC-2, AC-3<br />

230/240V [kW] ~ ~ ~ 0.06/0.09 0.12 0.18/0.25 0.37<br />

400/415V [kW] 0.02 0.06 0.09 0.12/0.18 0.25 0.37/0.55 0.75<br />

500V [kW] ~ ~ ~ 0.18 0.25/0.37 0.55/0.75 1.1<br />

690V [kW] ~ ~ ~ 0.25 0.37/0.55 0.75/1.1 1.8<br />

Back-up Fuses<br />

gG, gL, only if I cc<br />

>I cu<br />

230/240V [A] ➊ ➊ ➊ ➊ ➊ ➊ ➊<br />

400/415V [A] ➊ ➊ ➊ ➊ ➊ ➊ ➊<br />

440/460V [A] ➊ ➊ ➊ ➊ ➊ ➊ ➊<br />

500V [A] ➊ ➊ ➊ ➊ ➊ ➊ ➊<br />

690V [A] ➊ ➊ ➊ ➊ ➊ 16 20<br />

Ultimate Short-<strong>Circuit</strong><br />

Breaking Capacity<br />

I cu<br />

230/240V [kA] 100 100 100 100 100 100 100<br />

400/415V [kA] 100 100 100 100 100 100 100<br />

440/460V [kA] 100 100 100 100 100 100 100<br />

500V [kA] 100 100 100 100 100 100 100<br />

690V [kA] 100 100 100 100 100 10 8<br />

Rated Service Short-<strong>Circuit</strong><br />

Breaking Capacity<br />

I cs<br />

230/240V [kA] 100 100 100 100 100 100 100<br />

400/415V [kA] 100 100 100 100 100 100 100<br />

440/460V [kA] 100 100 100 100 100 100 100<br />

500V [kA] 100 100 100 100 100 100 100<br />

690V [kA] 100 100 100 100 100 8 8<br />

Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />

<strong>KT7</strong><br />

➊ No backup fuse required.<br />

F24<br />

Discount Schedule A-1


Technical Information<br />

<strong>KT7</strong> <strong>Motor</strong> <strong>Circuit</strong> Controller<br />

Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />

IEC Performance Data<br />

Catalog Number KTB7-25H...<br />

Catalog No. KTB7-45H...<br />

2.5A 4A 6.3A 10A 16A 25A 25A 32A 45A<br />

Rated Operational Current, I e<br />

[A] 2.5 4 6.3 10 16 25 25 32 45<br />

Magnetic Release Current [A] 32 52 82 130 208 325 325 416 585<br />

Switching of Standard<br />

Three-Phase <strong>Motor</strong>s<br />

AC-2, AC-3<br />

230/240V [kW] 0.37 0.55/0.75 1.1/1.5 2.2 3.0/4.0 ~ 5.5/6.3 7.5 11/13<br />

400/415V [kW] 0.75 1.1/1.5 2.2 3.0/4.0 5.5/7.5 11 11 15 18.5/22<br />

500V [kW] 1.1 1.5/2.2 2.5/3.0 4.0/6.3 7.5/10 15 15 15/20 22/30<br />

690V [kW] 1.8 2.2/3.0 4.0 5.5/7.5 11/13 18.5/22 18.5/22 22/25 30/40<br />

Back-up Fuses<br />

gG, gL, only if I cc<br />

>I cu<br />

230/240V [A] ➊ ➊ ➊ ➊ ➊ ➊ ➊ ➊ ➊<br />

400/415V [A] ➊ ➊ ➊ ➊ ➊ 100 100 125 125<br />

440/460V [A] ➊ ➊ ➊ ➊ 80 100 100 125 125<br />

500V [A] ➊ ➊ ➊ ➊ 80 80 100 125 125<br />

690V [A] 20 35 50 50 63 63 80 100 100<br />

Ultimate Short-<strong>Circuit</strong><br />

Breaking Capacity<br />

I cu<br />

230/240V [kA] 100 100 100 100 100 100 100 100 100<br />

400/415V [kA] 100 100 100 100 100 50 65 65 65<br />

440/460V [kA] 100 100 100 100 50 50 50 50 50<br />

500V [kA] 100 100 100 10 50 25 50 50 50<br />

690V [kA] 10 10 10 6 6 6 10 10 10<br />

Rated Service Short-<strong>Circuit</strong><br />

Breaking Capacity<br />

I cs<br />

230/240V [kA] 100 100 100 100 100 100 100 100 100<br />

400/415V [kA] 100 100 100 100 50 25 50 50 50<br />

440/460V [kA] 100 100 100 100 50 25 50 50 50<br />

500V [kA] 100 100 100 100 50 25 50 50 50<br />

690V [kA] 10 10 10 6 4 4 10 6 6<br />

F<br />

<strong>Motor</strong> <strong>Circuit</strong><br />

<strong>Controllers</strong><br />

➊ No backup fuse required.<br />

<strong>KT7</strong><br />

Discount Schedule A-1<br />

F25


Technical Information<br />

<strong>KT7</strong> <strong>Motor</strong> <strong>Circuit</strong> Controller<br />

F<br />

<strong>Motor</strong> <strong>Circuit</strong><br />

<strong>Controllers</strong><br />

IEC Performance Data<br />

Catalog Number KTC7-25S...<br />

0.16A 0.25A 0.4A 0.63A 1A 1.6A 2.5A 4A 6.3A 10A 16A<br />

Rated Operational Current, I e<br />

[A] 0.16 0.25 0.4 0.63 1 1.6 2.5 4 6.3 10 16<br />

Magnetic Release Current [A] 3.2 5.2 8.2 13 21 33 52 82 130 208 260<br />

Switching of Standard<br />

Three-Phase <strong>Motor</strong>s<br />

AC-2, AC-3<br />

230/240V [kW] ~ ~ ~ 0.06/0.09 0.12 0.18/0.25 0.37 0.55/0.75 1.1/1.5 2.2 3.0/4.0<br />

400/415V [kW] 0.02 0.06 0.09 0.12/0.18 0.25 0.37/0.55 0.75 1.1/1.5 2.2 3.0/4.0 5.5/7.5<br />

500V [kW] ~ ~ ~ 0.18 0.25/0.37 0.55/0.75 1.1 1.5/2.2 2.5/3.0 4.0/6.3 7.5/10<br />

690V [kW] ~ ~ ~ 0.25 0.37/0.55 0.75/1.1 1.8 2.2/3.0 4.0 5.5/7.5 11/13<br />

Back-up Fuses<br />

gG, gL, only if I cc<br />

>I cu<br />

230/240V [A] ➊ ➊ ➊ ➊ ➊ ➊ ➊ ➊ ➊ ➊ ➊<br />

400/415V [A] ➊ ➊ ➊ ➊ ➊ ➊ ➊ ➊ ➊ ➊ 80<br />

440/460V [A] ➊ ➊ ➊ ➊ ➊ ➊ ➊ ➊ ➊ ➊ 80<br />

500V [A] ➊ ➊ ➊ ➊ ➊ ➊ ➊ ➊ ➊ 80 80<br />

690V [A] ➊ ➊ ➊ ➊ ➊ 16 20 35 50 50 63<br />

Ultimate Short-<strong>Circuit</strong><br />

Breaking Capacity<br />

I cu<br />

230/240V [kA] 100 100 100 100 100 100 100 100 100 100 100<br />

400/415V [kA] 100 100 100 100 100 100 100 100 100 100 50<br />

440/460V [kA] 100 100 100 100 100 100 100 100 100 50 10<br />

500V [kA] 100 100 100 100 100 100 100 100 100 50 10<br />

690V [kA] 100 100 100 100 100 8 8 8 4 4 3<br />

Rated Service Short-<strong>Circuit</strong><br />

Breaking Capacity<br />

I cs<br />

230/240V [kA] 100 100 100 100 100 100 100 100 100 100 100<br />

400/415V [kA] 100 100 100 100 100 100 100 100 100 100 15<br />

440/460V [kA] 100 100 100 100 100 100 100 100 100 50 6<br />

500V [kA] 100 100 100 100 100 100 100 100 100 50 6<br />

690V [kA] 100 100 100 100 100 8 8 8 4 4 3<br />

Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />

<strong>KT7</strong><br />

➊ No backup fuse required.<br />

F26<br />

Discount Schedule A-1


Technical Information<br />

<strong>KT7</strong> <strong>Motor</strong> <strong>Circuit</strong> Controller<br />

Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />

IEC Performance Data<br />

Catalog No. KTC7-25H...<br />

Catalog No. KTC7-45H...<br />

16A 20A 25A 32A<br />

Rated Operational Current, I e<br />

[A] 16 20 25 32<br />

Magnetic Release Current [A] 260 325 416 585<br />

Switching of Standard<br />

Three-Phase <strong>Motor</strong>s<br />

AC-2, AC-3<br />

230/240V [kW] 3.0/4.0 4.0/5.5 5.5/6.3 7.5<br />

400/415V [kW] 5.5/7.5 7.5/10 11 15<br />

500V [kW] 7.5/10 11 15 15/20<br />

690V [kW] 11/13 15/17 18.5/22 22/25<br />

Back-up Fuses<br />

gG, gL, only if I cc<br />

>I cu<br />

230/240V [A] ➊ ➊ ➊ ➊<br />

400/415V [A] 80 100 100 125<br />

440/460V [A] 80 100 100 125<br />

500V [A] 80 80 100 125<br />

690V [A] 63 63 80 100<br />

Ultimate Short-<strong>Circuit</strong><br />

Breaking Capacity<br />

I cu<br />

230/240V [kA] 100 100 100 100<br />

400/415V [kA] 65 65 65 65<br />

440/460V [kA] 65 65 65 65<br />

500V [kA] 50 25 50 50<br />

690V [kA] 6 6 10 10<br />

Rated Service Short-<strong>Circuit</strong><br />

Breaking Capacity<br />

I cs<br />

230/240V [kA] 100 100 100 100<br />

400/415V [kA] 25 25 50 50<br />

440/460V [kA] 25 25 50 50<br />

500V [kA] 25 25 50 50<br />

690V [kA] 4 4 6 6<br />

F<br />

<strong>Motor</strong> <strong>Circuit</strong><br />

<strong>Controllers</strong><br />

➊ No backup fuse required.<br />

<strong>KT7</strong><br />

Discount Schedule A-1<br />

F27


Technical Information<br />

<strong>KT7</strong> <strong>Motor</strong> <strong>Circuit</strong> Controller<br />

F<br />

<strong>Motor</strong> <strong>Circuit</strong><br />

<strong>Controllers</strong><br />

<strong>KT7</strong><br />

General Data<br />

<strong>KT7</strong>-25S <strong>KT7</strong>-25H <strong>KT7</strong>-45H<br />

Rated Insulation Voltage<br />

IEC, SEV, VDE 0660<br />

690V<br />

UL, CSA<br />

600V<br />

Rated Impulse Withstand Voltage<br />

(main & auxiliary circuits)<br />

Uimp/pollution degree<br />

6kV/3<br />

Rated Frequency<br />

50/60 Hz<br />

Utilization Category<br />

• IEC 60949-2 (<strong>Motor</strong> Protector)<br />

A<br />

• IEC 60949-4-1 (<strong>Motor</strong> Starter)<br />

AC-3<br />

Life Span<br />

Mechanical [operations] 100,000 100,000 100,000<br />

<strong>Electric</strong>al (Ie max.) [operations] 100,000 100,000 100,000<br />

Switching Frequency [operations] max. 25/h. (motor starts)<br />

Ambient Temperature<br />

Storage<br />

-40º C...+80º C<br />

Operation<br />

-25º C...+60º C<br />

Resistance to Climatic Change IEC 68-2<br />

Moisture / Heat Resistance<br />

40ºC, 92% relative humidity, 56 days<br />

Moisture / Change Resistance<br />

23ºC, 93% relative humidity / 40ºC, 92% relative humidity, 56 days<br />

Site Altitude<br />

to 2,000 m N.N.<br />

Protection Class<br />

IP20 all round, when wired<br />

Resistance to Shock<br />

30 G, 11 ms<br />

Resistance to Vibration IEC 68-2<br />

Rated Thermal Current I th<br />

IEC, SEV, VDE 0660<br />

Up to 60º C ambient temperature [A] 0.1...25 1.6...25 6.3...45<br />

Overload Protection<br />

Characteristics<br />

Ambient temperature<br />

IEC 947-4-1 <strong>Motor</strong> protection (except KTB7)<br />

Compensation<br />

-20º C...+60º C<br />

Phase-failure protection<br />

yes, differential release<br />

Magnetic Release<br />

Response Current<br />

fixed setting<br />

13 x /emax. (for KTC7)<br />

16...20 x /emax. (for KTC7)<br />

I e<br />

max.=maximum values of setting ranges<br />

Total Power Loss P v<br />

<strong>Motor</strong> protector at rated load<br />

Operating temperature [W] 6...8 6...8 9...16<br />

Weights<br />

Description Catalog Number Weight<br />

KTA7-25S<br />

317 g<br />

KTA7-25H<br />

373 g<br />

KTA7-45H<br />

782 g<br />

KTB7-25S<br />

315 g<br />

<strong>Motor</strong> Protectors<br />

KTB7-25H<br />

365 g<br />

KTB7-45H<br />

782 g<br />

KTC7-25S<br />

315 g<br />

KTC7-25H<br />

365 g<br />

KTC7-45H<br />

782 g<br />

Auxiliary Contacts<br />

<strong>KT7</strong>-PE1<br />

<strong>KT7</strong>-PA1<br />

10 g<br />

<strong>KT7</strong>-PEF1<br />

<strong>KT7</strong>-PAF1<br />

15 g<br />

<strong>KT7</strong>-UA-✱<br />

108 g<br />

Undervoltage Trip<br />

<strong>KT7</strong>-<strong>AA</strong>-✱<br />

110 g<br />

<strong>KT7</strong>-UA-L20-✱ 116 g<br />

Anti-Tamper Cover <strong>KT7</strong>-25-CA 2 g<br />

Lockable Twist Knob<br />

<strong>KT7</strong>-KN<br />

<strong>KT7</strong>-KRY<br />

5 g<br />

Locking Tag <strong>KT7</strong>-DS 30 g<br />

Door Coupling Handle<br />

<strong>KT7</strong>-HTN<br />

<strong>KT7</strong>-HTRY<br />

123 g<br />

Description Catalog Number Weight<br />

Extension Shaft <strong>KT7</strong>-HT 46 g<br />

Lengend Plate <strong>KT7</strong>-HTFC 4 g<br />

Feeder Terminal<br />

<strong>KT7</strong>-25-A3<br />

<strong>KT7</strong>-45-A3<br />

172 g<br />

<strong>KT7</strong>-25-DB-45-2 47 g<br />

<strong>KT7</strong>-25-DB-45-3 80 g<br />

<strong>KT7</strong>-25-DB-45-4 104 g<br />

<strong>KT7</strong>-25-DB-45-5 132 g<br />

<strong>KT7</strong>-25-DB-54-2 52 g<br />

Commoning Links<br />

<strong>KT7</strong>-25-DB-54-3 86 g<br />

<strong>KT7</strong>-25-DB-54-4 118 g<br />

<strong>KT7</strong>-25-DB-54-5 154 g<br />

<strong>KT7</strong>-25-DB-63-2 56 g<br />

<strong>KT7</strong>-25-DB-63-3 92 g<br />

<strong>KT7</strong>-25-DB-63-4 134 g<br />

<strong>KT7</strong>-25-DB-63-5 170 g<br />

Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />

F28<br />

Discount Schedule A-1


Technical Information<br />

<strong>KT7</strong> <strong>Motor</strong> <strong>Circuit</strong> Controller<br />

Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />

General Data<br />

Conformity to Standards<br />

Approvals<br />

Terminal Parts<br />

Terminal Type<br />

Accessories for <strong>KT7</strong> <strong>Motor</strong> <strong>Circuit</strong> <strong>Controllers</strong><br />

Auxiliary Contact<br />

Blocks for<br />

Front Mounting<br />

Catalog Number<br />

<strong>KT7</strong>-PE1, <strong>KT7</strong>-PEF1<br />

Auxiliary Contact<br />

Blocks for<br />

Right-Side Mounting<br />

Catalog Number<br />

<strong>KT7</strong>-PA1, <strong>KT7</strong>-PAF1<br />

Rated Thermal Current I th<br />

at 40ºC ambient temperature 5 10<br />

at 40ºC ambient temperature [A] 4 6<br />

Contact Class Coordination<br />

According to NEMA AC B 300 B 600<br />

(UL/CSA Standards) DC Q 300 Q 600<br />

Back-Up Fuses gG, gL [A] 10 10<br />

Rated Thermal Current I th<br />

AC-15 [V] 24 120 240 24 120 240 415 690<br />

[A] 4 3 1.5 6 5 3 2 0.7<br />

DC-13 [V] 24 120 240 24 120 240 415<br />

[A] 2 0.5 0.25 2 0.5 0.25 0.15<br />

Terminal Parts<br />

Terminal Type<br />

<strong>KT7</strong>-25S <strong>KT7</strong>-25H <strong>KT7</strong>-45H<br />

IEC 60947-1, -2; -4-1<br />

EN 60947-1, -2; -4-1<br />

UL 508; CSA 22.2<br />

CE, UL, CSA<br />

Screwdriver Pozidriv No. 2/Blade No. 3 Pozidriv No. 2/Blade No. 3<br />

1 conductor [mm 2 ]/[AWG] 1...4 / No. 16...10 2.5...16 / No. 14...4<br />

2 conductor [mm 2 ]/[AWG] 1...4 / No. 16...10 2.5...10 / No. 14...4<br />

1 conductor [mm 2 ]/[AWG] 1...6 / No. 16...10 2.5...25 / No. 14...4<br />

2 conductor [mm 2 ]/[AWG] 1...6 / No. 16...10 2.5...16 / No. 14...4<br />

1 conductor [mm 2 ]/[AWG] 1.5...6 / No. 16...10 2.5...25 / No. 14...4<br />

2 conductor [mm 2 ]/[AWG] 1.5...6 / No. 16...10 2.5...16 / No. 14...4<br />

Tightening torque [Nm]/[lb-in.] 2...2.5 / 18...22 3...3.5 / 27...31<br />

Screwdriver Pozidriv No. 2/Blade No. 3<br />

1 conductor [mm 2 ]/[AWG] 0.5...2.5 / No. 18...14<br />

2 conductor [mm 2 ]/[AWG] 0.5...2.5 / No. 18...14<br />

1 conductor [mm 2 ]/[AWG] 0.75...2.5 / No. 18...14<br />

2 conductor [mm 2 ]/[AWG] 0.75...2.5 / No. 18...14<br />

1 conductor [mm 2 ]/[AWG] 0.75...2.5 / No. 18...14<br />

2 conductor [mm 2 ]/[AWG] 0.75...2.5 / No. 18...14<br />

Tightening torque [Nm]/[lb-in.] 1.2...1.5 / 10.6...13<br />

Lockable Twist Knob (<strong>KT7</strong>-KN & <strong>KT7</strong>-KRY)<br />

Tightening torque [Nm]/[lb-in.] 1 / 8.8 (T10)<br />

Mounting Depth – Door Coupling Handles (All <strong>KT7</strong>-HT...)<br />

Mounting Depth when using motor circuit controller:<br />

<strong>KT7</strong>-25S [mm]/[in.] 105.5 mm ± 5 mm (4.15” ± 3/16”)<br />

<strong>KT7</strong>-25H [mm]/[in.] 114.5 mm ± 5 mm (4.5” ± 3/16”)<br />

<strong>KT7</strong>-45H [mm]/[in.] 137.1 mm ± 5 mm (5.4” ± 3/16”)<br />

Mounting Depth – Extension Shaft (<strong>KT7</strong>-HT)<br />

Mounting Depth range when using motor circuit controller:<br />

<strong>KT7</strong>-25S [mm]/[in.] 117...338 mm (4.6”...13.3”)<br />

<strong>KT7</strong>-25H [mm]/[in.] 126...347 mm (5.0”...13.7”)<br />

<strong>KT7</strong>-45H [mm]/[in.] 149...369 mm (5.4”...14.5”)<br />

F<br />

<strong>Motor</strong> <strong>Circuit</strong><br />

<strong>Controllers</strong><br />

<strong>KT7</strong><br />

Discount Schedule A-1<br />

F29


Technical Information<br />

<strong>KT7</strong> <strong>Motor</strong> <strong>Circuit</strong> Controller<br />

F<br />

<strong>Motor</strong> <strong>Circuit</strong><br />

<strong>Controllers</strong><br />

Accessories<br />

Undervoltage Trip for<br />

Left-Side Mounting<br />

Cat. Number <strong>KT7</strong>-UA-*<br />

Undervoltage Trip with<br />

2 Auxiliary Contacts for<br />

Left-Side Mounting<br />

Cat. Number <strong>KT7</strong>-UA-L20-*<br />

Shunt Trip for<br />

Left-Side Mounting<br />

Cat. Number <strong>KT7</strong>-<strong>AA</strong>-*<br />

Actuating Voltage Pull-in 0.85...1.1 x U s 0.85...1.1 x U s<br />

0.7...1.1 x U s<br />

Drop-out 0.7...0.35 x U s 0.7...0.35 x U s<br />

Rated Control Voltage minimum 21V 50 Hz, 24V 60 Hz 21V 50 Hz, 24V 60 Hz 21V 50 Hz, 24V 60 Hz<br />

maximum 600V 50 Hz 600V 50 Hz 600V 50 Hz<br />

On-Time 100% 100% 100%<br />

Coil Rating Pull-in 8.5 VA, 6 W 8.5 VA, 6 W 8.5 VA, 6 W<br />

Hold 3 VA, 1.2 W 3 VA, 1.2 W 3 VA, 1.2 W<br />

Terminal Parts<br />

Terminal Type<br />

Screwdriver Pozidriv No. 2/Blade No. 3<br />

1 conductor [mm 2 ]/[AWG] 0.5...2.5 / No. 18...14<br />

2 conductor [mm 2 ]/[AWG] 0.75...2.5 / No. 18...14<br />

1 conductor [mm 2 ]/[AWG] 0.75...2.5 / No. 18...14<br />

2 conductor [mm 2 ]/[AWG] 0.75...2.5 / No. 18...14<br />

1 conductor [mm 2 ]/[AWG] 0.75...2.5 / No. 18...14<br />

2 conductor [mm 2 ]/[AWG] 0.75...2.5 / No. 18...14<br />

Tightening torque [Nm]/[lb-in.] 1.2...1.5 / 10.6...13.3<br />

Feeder Terminal<br />

<strong>KT7</strong>-25-A3(E)<br />

Compact Busbar<br />

<strong>KT7</strong>-25-DB...<br />

Feeder Terminal<br />

<strong>KT7</strong>-45-A3(E)<br />

Compact Bushbar<br />

<strong>KT7</strong>-45-DB...<br />

Rated Thermal Current I th<br />

[V] 600 600 600 600<br />

at 60º C ambient temperature [A] 64 64 120 120<br />

1 conductor [mm 2 ]/[AWG] 4...16 / No. 12...6 ~ #8...1/0 ~<br />

1 conductor [mm 2 ]/[AWG] 6...25 / No. 14...4 ~ ~<br />

1 conductor [mm 2 ]/[AWG] 6...25 / No. 14...4 ~ ~<br />

Tightening torque [Nm]/[lb-in.] 3 / 27 ~ 27...54 ~<br />

Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />

<strong>KT7</strong><br />

F30<br />

Discount Schedule A-1


Technical Information<br />

<strong>KT7</strong> <strong>Motor</strong> <strong>Circuit</strong> Controller<br />

Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />

Time-Current Characteristic<br />

<strong>KT7</strong> <strong>Manual</strong> <strong>Motor</strong> Starter/Protector<br />

Cut-off Current<br />

<strong>KT7</strong>-25S<br />

1. Thermal Release Trip Current<br />

The adjustable current-dependent delayed bimetal release protects<br />

motors against overload. The curve shows the mean operating<br />

current at an ambient temperature of 20°C starting from the cold<br />

state. Careful testing and setting ensures effective motor protection<br />

even in the case of single-phasing. The overload characteristic is<br />

also valid for transformer protection.<br />

2. Magnetic Release Trip Current<br />

The instantaneous magnetic trip has a fixed operating current<br />

setting. This corresponds to 13 times the maximum value of setting<br />

range (high inrush protection -20 x I e<br />

maximum). At a lower<br />

overload setting the magnetic trip is correspondingly higher.<br />

Current Setting I ef<br />

The overload trip corresponds to a thermal overload relay in a<br />

motor starter conforming to IEC 947-4-1. If a different value is<br />

prescribed (e.g., reduced I e<br />

for cooling medium having a temperature<br />

higher than 40°C or a place of installation higher than 2000 m<br />

above sea level), the setting current is equal to the reduced rated<br />

current I e<br />

of the motor.<br />

F<br />

<strong>Motor</strong> <strong>Circuit</strong><br />

<strong>Controllers</strong><br />

<strong>KT7</strong><br />

Discount Schedule A-1<br />

F31


Technical Information<br />

<strong>KT7</strong> <strong>Motor</strong> <strong>Circuit</strong> Controller<br />

F<br />

<strong>Motor</strong> <strong>Circuit</strong><br />

<strong>Controllers</strong><br />

Cut-off Current<br />

<strong>KT7</strong>-25H and <strong>KT7</strong>-45H<br />

Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />

<strong>KT7</strong><br />

F32<br />

Discount Schedule A-1


Technical Information<br />

KF7 with <strong>KT7</strong> <strong>Motor</strong> <strong>Circuit</strong> Controller<br />

Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />

<strong>KT7</strong> <strong>Motor</strong> <strong>Circuit</strong> KF7 Fuse <strong>Controllers</strong> Holder (without used with Terminal CA7 Contactor Adaptor <strong>KT7</strong>-25[45]-TE)<br />

<br />

<br />

<br />

<br />

<br />

<br />

KF7 Fuse Holder used with KTA7 <strong>Motor</strong> <strong>Circuit</strong> Controller and CA7 Contactor<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

F<br />

<strong>Motor</strong> <strong>Circuit</strong><br />

<strong>Controllers</strong><br />

KF7<br />

Discount Schedule A-1<br />

F33


Technical Information<br />

<strong>KT7</strong> <strong>Motor</strong> <strong>Circuit</strong> Controller<br />

F<br />

<strong>Motor</strong> <strong>Circuit</strong><br />

<strong>Controllers</strong><br />

<strong>KT7</strong><br />

• Dimensions are shown in millimeters (inches).<br />

• Dimensions are not intended to be used for<br />

manufacturing purposes.<br />

<strong>KT7</strong> Bus Bar and Supply Blocks<br />

CA7/<strong>KT7</strong> Connection Modules and Kits<br />

1) Ecombo Modules<br />

<strong>Electric</strong>al and mechanical connection between motor circuit controller and contactors with AC coil. For CA7-9...23 only. Compatible with the reversing- and WYE-delta<br />

starter components.<br />

2) Standard Connection Modules<br />

<strong>Electric</strong>al connection between motor circuit controller and contactors with AC coil. For CA7-9...45. Compatible with the reversing- and WYE-delta starter components.<br />

3) Coil Extension Modules<br />

Simplifies access to the coil terminals on 3-component starters.<br />

For CA7-9...23 = <strong>KT7</strong>-25S-PSC23<br />

For CA7-30...43 = <strong>KT7</strong>-45H-PSC43<br />

Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />

F34<br />

Discount Schedule A-1


Dimensions<br />

<strong>KT7</strong> <strong>Motor</strong> <strong>Circuit</strong> Controller<br />

Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />

• Dimensions are shown in millimeters (inches).<br />

• Dimensions are not intended to be used for<br />

manufacturing purposes.<br />

<strong>KT7</strong> <strong>Motor</strong> <strong>Circuit</strong> <strong>Controllers</strong> (without Terminal Adaptor <strong>KT7</strong>-25[45]-TE)<br />

a b c1 c2<br />

<strong>KT7</strong>-25S 117...338 105.5 ± 5 49.5 40.5<br />

<strong>KT7</strong>-25H 126...347 114.5 ± 5 49.5 40.5<br />

<strong>KT7</strong>-45H 148.6...369.6 137.1 ± 5 59.35 50.35<br />

➊ Mounting on 35 mm DIN Rail EN 50 022-35<br />

➋ Auxiliary contact (side-mounted).<br />

Adds 9mm (23/64)<br />

➌ Undervoltage trip or Shunt trip<br />

➍ Auxiliary contact (front-mounted)<br />

F<br />

<strong>Motor</strong> <strong>Circuit</strong><br />

<strong>Controllers</strong><br />

<strong>KT7</strong><br />

Discount Schedule A-1<br />

F35


Dimensions<br />

<strong>KT7</strong> <strong>Motor</strong> <strong>Circuit</strong> Controller<br />

F<br />

<strong>Motor</strong> <strong>Circuit</strong><br />

<strong>Controllers</strong><br />

• Dimensions are shown in millimeters (inches).<br />

• Dimensions are not intended to be used for<br />

manufacturing purposes.<br />

<strong>KT7</strong> <strong>Motor</strong> <strong>Circuit</strong> <strong>Controllers</strong> (without Terminal Adaptor <strong>KT7</strong>-25[45]-TE)<br />

<strong>KT7</strong>-25S with Terminal Adaptor <strong>KT7</strong>-25-TE<br />

<strong>KT7</strong>-45H with Terminal Adaptor <strong>KT7</strong>-45-TE<br />

<strong>KT7</strong>-25H with Terminal Adaptor <strong>KT7</strong>-25-TE<br />

Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />

<strong>KT7</strong><br />

F36<br />

Discount Schedule A-1


Dimensions<br />

Mounting Modules<br />

Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />

Mounting Modules<br />

• Dimensions are shown in millimeters (inches).<br />

• Dimensions are not intended to be used for manufacturing purposes.<br />

Mounting Modules – <strong>KT7</strong>-WS45(54)RR & <strong>KT7</strong>-WM45(54)RR<br />

Catalog Number A B C D E F<br />

KA7-WS45RR 228<br />

(8-31/32)<br />

KA7-WS5RR 228<br />

(8-31/32)<br />

KA7-WM45RR 283<br />

(11-9/64)<br />

KA7-WM5RR 283<br />

(11-9/64)<br />

45<br />

(1-25/32)<br />

54<br />

(2-1/8)<br />

45<br />

(1-25/32)<br />

54<br />

(2-1/8)<br />

69<br />

(2-23/32)<br />

69<br />

(2-23/32)<br />

69<br />

(2-23/32)<br />

69<br />

(2-23/32)<br />

165.5<br />

(6-35/64)<br />

174<br />

(6-27/32)<br />

166.5<br />

(6-35/64)<br />

174<br />

(6-27/32)<br />

210<br />

(8-17/64)<br />

210<br />

(8-17/64)<br />

265<br />

(10-7/16)<br />

265<br />

(10-7/16)<br />

35<br />

(1-3/8)<br />

40<br />

(1-37/64)<br />

40<br />

(1-37/64)<br />

40<br />

(1-37/64)<br />

F<br />

<strong>Motor</strong> <strong>Circuit</strong><br />

<strong>Controllers</strong><br />

<strong>KT7</strong><br />

Discount Schedule A-1<br />

F37


Technical Information<br />

KTA3-100 <strong>Motor</strong> <strong>Circuit</strong> Controller<br />

F<br />

<strong>Motor</strong> <strong>Circuit</strong><br />

<strong>Controllers</strong><br />

IEC Performance Data<br />

(CSA C22.2, UL 508 No. 14 in connection with a short-circuit protection device<br />

Catalog No. KTA3-100...<br />

25A 40A 63A 90A<br />

Maximum Short-<strong>Circuit</strong> Current<br />

480V [kA] 65 65 42 35<br />

600V [kA] 42 42 18 10<br />

<strong>Motor</strong> Load, Single-Phase<br />

115V [HP] 2 3 5 7-1/2<br />

200V [HP] 3 5 10 15<br />

230V [HP] 3 7-1/2 10 20<br />

<strong>Motor</strong> Load, Three-Phase<br />

200V [HP] ~ ~ ~ ~<br />

230V [HP] 7-1/2 10 20 30<br />

460V [HP] 15 30 40 60<br />

575V [HP] 20 30 60 75<br />

Maximum Rated Current of the<br />

Protective Device [A] 2000<br />

IEC Performance Data<br />

Catalog No. KTA3-100...<br />

25A 40A 63A 90A<br />

Switching of Three-Phase <strong>Motor</strong>s<br />

AC-2, AC-3<br />

230/240V [kW] 5.5/7.5 10/11 12.5/20 22/25<br />

400/415V [kW] 7.5/12.5 15/22 25/31.5 37/45<br />

500V [kW] 11/16 18.5/25 30/40 45/55<br />

690V [kW] 15/22 25/30 37/55 63/75<br />

<strong>Motor</strong> Load, Single-Phase<br />

gG, aM, only if I cc<br />

>I cu<br />

230/240V [A] ~ ~ ~ ~<br />

400/415V [A] 160 160 160 160<br />

500V [A] 160 160 160 160<br />

690V [A] 160 160 160 160<br />

Ultimate Short-<strong>Circuit</strong> Breaking Capacity I cu<br />

200V [kA] ~ ~ ~ ~<br />

230V [kA] 7-1/2 10 20 30<br />

460V [kA] 15 30 40 60<br />

575V [kA] 20 30 60 75<br />

Rated Short-<strong>Circuit</strong> Breaking Capacity I cs<br />

200V [kA] 100 100 100 100<br />

230V [kA] 65 50 50 25<br />

460V [kA] 50 25 25 13<br />

575V [kA] 15 8 6 6<br />

Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />

KTA3<br />

F38 Discount Schedule A-1


Technical Information<br />

Series KTA3-100 <strong>Motor</strong> <strong>Circuit</strong> Controller<br />

Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />

General Data<br />

Catalog Number KTA3-100<br />

Rated Isolation Voltage<br />

IEC, SEV, VDE 0660<br />

690V<br />

UL, CSA<br />

600V<br />

Rated Frequency<br />

40...80 Hz<br />

Lifespan<br />

Mechanical<br />

30,000 operations<br />

<strong>Electric</strong>al<br />

10,000 operations at 63 A<br />

5,000 operations at 90 A<br />

Switching Frequency<br />

maximum 20 ops/hr<br />

Ambient Temperature<br />

Storage<br />

-25...+80ºC (-13...176ºF)<br />

Operation<br />

-25...+60ºC (-13...140ºF)<br />

Corrosion Resistance C IV (per IEC 68)<br />

Resistance to heat and humidity<br />

40ºC, 92%, 56 days<br />

Resistance to cyclic heat and humidity<br />

23ºC, 83%/40ºC, 93%, 56 cycles<br />

Type of Protection<br />

IP20 enclosed state<br />

Resistance to Shock [G] 30, 11 ms<br />

Resistance to Vibration<br />

Frequency range<br />

10...150 Hz<br />

In all directions<br />

in testing<br />

Rated Thermal Current I th<br />

IEC, SEV, VDE 0660 ~<br />

At 40ºC ambient temperature<br />

16...90 A<br />

At 60ºC ambient temperature<br />

4 adjustment ranges<br />

Rated current I e<br />

16...90 A<br />

Rated Impulse Voltage/Pollution<br />

Main circuits<br />

6 kV/3<br />

Auxiliary circuits<br />

6 kV/3<br />

Overload Protection<br />

Characteristics motor protection per IEC 947<br />

Temperature compensation<br />

-25...+60ºC (-4...140ºF)<br />

Phase failure protection<br />

differential release<br />

Magnetic Release<br />

Operating current<br />

fixed setting<br />

14 x I e<br />

maximum<br />

I e<br />

maximum = maximum value of adjustment range<br />

Power Loss P v<br />

At maximum rated current and with<br />

switch at rated operating temperature<br />

33 W<br />

Standards<br />

IEC 947-1/2/4/5;<br />

EN 60947;<br />

UL 508; CSA 22.2<br />

Approvals<br />

CE, CSA, UL<br />

Lloyd’s Register of Shipping<br />

Terminals<br />

Terminal Type<br />

Flexible [mm 2 ] 1 x 2.5...35<br />

Stranded [mm 2 ] 1 x 4...50<br />

Breakaway Torque [Nm] 6...10<br />

Stranded [mm 2 ] No. 12...2<br />

Breakaway Torque [lb-in.] 53...120<br />

Weight<br />

3-pole circuit breaker [g] 1845 (4.10)<br />

F<br />

<strong>Motor</strong> <strong>Circuit</strong><br />

<strong>Controllers</strong><br />

KTA3<br />

Discount Schedule A-1<br />

F39


Technical Information<br />

Series KTA3-100 <strong>Motor</strong> <strong>Circuit</strong> Controller<br />

F<br />

<strong>Motor</strong> <strong>Circuit</strong><br />

<strong>Controllers</strong><br />

General Data<br />

Integrated Short-<strong>Circuit</strong> Indicator<br />

in Catalog Number KTA3-100-UA...and KTA3-100<strong>AA</strong>...<br />

Rated Thermal Current I th<br />

At 40ºC ambient temperature [A] 2<br />

At 60ºC ambient temperature [A] 2<br />

Back-Up Fuse gl, gL [A] 10<br />

Rated Current<br />

Terminals<br />

Terminal Type<br />

AC-15<br />

AC-15<br />

AC-14<br />

AC-14<br />

24V 110V 230V 500V<br />

1.5A 1.5A 1.0A 0.75A<br />

24V 48V 60V ~<br />

1.5A 0.5A 0.4A ~<br />

Flexible [mm 2 ] 2 x 0.75...2.5<br />

Stranded [mm 2 ] 2 x 0.75...2.5<br />

Breakaway Torque [Nm] 1...1.5<br />

Stranded [mm 2 ] No. 18...12<br />

Breakaway Torque [lb-in.] 8.8...10.3<br />

Weight [g (lb)] 91 (0.21)<br />

Operating Voltage<br />

Pick-up<br />

Drop-out<br />

Duty cycle<br />

Undervoltage Trip Unit for Front Mounting<br />

on Catalog Number KTA3-100<br />

0.85...1.1 x Us<br />

0.7...0.35 x Us<br />

continuous<br />

Control Voltage min. 21V 50 Hz / 24V 60 Hz<br />

max.<br />

600V 50 Hz<br />

Coil Performance<br />

Terminals<br />

Terminal Type<br />

pick-up<br />

drop-out<br />

upon inquiry<br />

Flexible [mm 2 ] / [AWG] 2 x 0.50...2.5 (18...14)<br />

Stranded [mm 2 ] / [AWG] 2 x 0.75...2.5 (18...14)<br />

Tightening Torque [Nm] / [lb-in] 1.2...1.5 (10.6...13.3)<br />

Weight [g (lb)] 94 (0.21)<br />

Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />

KTA3<br />

F40 Discount Schedule A-1


Technical Information<br />

KTA3-100 <strong>Motor</strong> <strong>Circuit</strong> Controller<br />

Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />

Cut-Off Current<br />

KTA3-100 <strong>Motor</strong> <strong>Circuit</strong> Controller<br />

Maximum Cut-Off Current<br />

Rated Operating Voltage 415V<br />

Protection of PVC Insulated Leads Against Overload and During Short-<strong>Circuit</strong><br />

Protected Minimum Copper Cross-Section at 400V 50 Hz<br />

Catalog Number 10 mm 2 6 mm 2 4 mm 2 2.5 mm 2 1.5 mm 2 1 mm 2 0.75 mm 2<br />

KTA3-100-25A • • • • ~ ~ ~<br />

KTA3-100-40A • • • ~ ~ ~ ~<br />

KTA3-100-63A • • ~ ~ ~ ~ ~<br />

KTA3-100-90A • ~ ~ ~ ~ ~ ~<br />

Maximum Forward Energy<br />

Rated Operating Voltage 415V<br />

As per IEC 364 and CENELEC coordination documents 384-3 and 384-3.<br />

In the Bulletin KTA3-100 <strong>Motor</strong> Protector, overload protection is achieved by means of the adjustable thermal releases. The maximum possible tripping current is substantially<br />

lower than in fused overload protection. Short-circuit protection is provided by the non-adjustable magnetic release which is capable of opening the main contacts very quickly.<br />

The short total breaking time limits temperature rise in the lead to a minimum in the event of a short-circuit.<br />

F<br />

<strong>Motor</strong> <strong>Circuit</strong><br />

<strong>Controllers</strong><br />

KTA3<br />

Discount Schedule A-1<br />

F41


Technical Information<br />

KTA3-100 <strong>Motor</strong> <strong>Circuit</strong> Controller<br />

F<br />

<strong>Motor</strong> <strong>Circuit</strong><br />

<strong>Controllers</strong><br />

KTA3<br />

Time-Current Characteristic<br />

KTA3-100 <strong>Manual</strong> <strong>Motor</strong> Starter/Protector<br />

Note: In certain applications such as in multi-speed motors or star-delta starters<br />

for heavy duty start and/or reduced motor lead cross-sections, the KTA3-100<br />

devices are used only as short-circuit protection, while overload protection is<br />

accomplished by thermal overload relays. The KTA3-100 motor protector must be<br />

set for a 20% higher current so that only the downstream thermal overload relays<br />

trip in the event of an overload.<br />

1. Thermal Release Operating Current<br />

The adjustable current-dependent delayed bimetal release<br />

protects motors against overload. The characteristic shows the<br />

mean at 20°C ambient temperature starting from the cold state.<br />

In equipment at operating temperature, release time is less<br />

than or equal to release time from the cold state. The precise<br />

routine test guarantees motor protection even when a phase is<br />

interrupted.<br />

<strong>Motor</strong> protection in protection type EExe: Pursuant to VDE<br />

0165/83, the release time of the cold overload release must be<br />

less than the allowed locked-rotor time t E<br />

of the motor.<br />

The specific tripping characteristics must be available at the<br />

operating site. If necessary, they can be ordered from the<br />

appropriate Sprecher + Schuh Sales Office. For new systems,<br />

protection equipment must be provided for motors in<br />

accordance with VDE 0165/83, section 6.1.4.3.3. Such<br />

protection equipment must ensure motor protection even in the<br />

event of a phase failure.<br />

2. Operating Current for Magnetic Releases<br />

Electromagnetic instantaneous releases react at a set tripping<br />

current. At the upper thermal release setting, this tripping<br />

current is 11 times or 14 times the set current at a lower<br />

setting.<br />

Current To Be Set<br />

Thermal releases meet the requirements for a thermal release<br />

for a starter in accordance with IEC 947. If a different value is<br />

specified (such as reduced I e<br />

in motors with a coolant temperature<br />

higher than 40°C or a site altitude >2000 m above M.S.L.), the<br />

rated operating current I e<br />

must be adjusted.<br />

Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />

F42 Discount Schedule A-1


Dimensions<br />

KTA3-100 <strong>Motor</strong> <strong>Circuit</strong> Controller<br />

Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />

• Dimensions are shown in millimeters (inches).<br />

• Dimensions are not intended to be used for<br />

manufacturing purposes.<br />

KTA3-100 <strong>Motor</strong> <strong>Circuit</strong> Controller<br />

F<br />

<strong>Motor</strong> <strong>Circuit</strong><br />

<strong>Controllers</strong><br />

KTA3<br />

Discount Schedule A-1<br />

F43


F<br />

<strong>Motor</strong> <strong>Circuit</strong><br />

<strong>Controllers</strong><br />

Ecom<br />

Ecombo and<br />

EcomboPlus<br />

<strong>Starters</strong><br />

Save space,<br />

save money<br />

in individual or<br />

multi-motor<br />

starter applications<br />

The Ecombo starter line combines a KTA7 selfprotected<br />

Type E combination controller with a<br />

CA7 contactor to form a cost effective compact<br />

alternative to traditional combination starters.<br />

R<br />

Sprecher + Schuh’s new Ecombo and<br />

EcomboPlus starters are the compact<br />

alternative to larger and higher priced<br />

combination starters. Both models<br />

consist of a KTA7 <strong>Motor</strong> <strong>Circuit</strong><br />

Controller (UL / CSA listed as a<br />

Type E, self-protected combination<br />

starter), and a CA7 or CA4 contactor<br />

which provides remote operation.<br />

Whether used as a standalone starter<br />

or in multi-motor starter applications,<br />

Ecombo and EcomboPlus starters save<br />

significant panel space and dollars<br />

over conventional combination starter<br />

alternatives.<br />

Control and protection for<br />

most industrial applications<br />

The Ecombo starter line covers motors<br />

to 15HP (@460/600V), while<br />

providing current limiting short circuit<br />

protection to 65kA. Class 10 thermal<br />

overload protection is also assured with<br />

a very accurate current adjustment setting<br />

which is factory calibrated to the<br />

smallest and largest current the unit<br />

can handle. A “differential tripping”<br />

mechanism also provides accelerated<br />

tripping under single phase conditions<br />

(see illustration on page F3). Ecombo<br />

starters may be selected as Type 2 Coordinated<br />

per IEC 60947-4-1, U250E<br />

or UL Construction Type E or F.<br />

The Ecombo starter…<br />

Ecombo starters come standard with<br />

a KTA7 <strong>Motor</strong> <strong>Circuit</strong> Controller<br />

connected to Sprecher + Schuh’s CA7<br />

contactor (or CA4 mini contactor)<br />

through a specially designed connection<br />

module. The unit is DIN-rail<br />

mounted. Contactor coil connections<br />

are at the bottom of the starter to provide<br />

attractive and cost effective panel<br />

wiring. Ecombo starters may also be<br />

purchased with just three parts and assembled<br />

by the user to further increase<br />

economy.<br />

Ecombo starter<br />

EcomboPlus starter<br />

EcomboPlus…<br />

the complete solution<br />

The EcomboPlus starter is factory assembled<br />

on a special socket base that<br />

provides support and allows the starter<br />

to be mounted on one or two DINrails<br />

or screw mounted. Each starter<br />

comes standard with a front mounted<br />

auxiliary trip contact that is pre-wired<br />

to a built-in terminal block at the bottom<br />

of the unit. Contactor coil connections<br />

are also at the bottom of the<br />

starter to provide attractive and cost<br />

effective panel wiring.<br />

Reduce panel size,<br />

complexity and cost<br />

Because <strong>KT7</strong> <strong>Motor</strong> <strong>Circuit</strong> <strong>Controllers</strong><br />

are UL listed as self-protected<br />

combination starters, NEC / CEC<br />

group motor rules are simplified<br />

substantially. In many cases, only a<br />

non-fused switch is required for panel<br />

disconnect. See “Methods of Applying<br />

<strong>KT7</strong> <strong>Motor</strong> <strong>Circuit</strong> <strong>Controllers</strong>”<br />

in this publication, which explains<br />

applying <strong>KT7</strong>s in multi-motor starter<br />

applications.<br />

Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />

F44


Catalog Number Coding<br />

CL4 and CL7 Ecombo / CK7 EcomboPlus<br />

Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />

Starter Type<br />

EcomboPlus Starter with CA7<br />

CK7<br />

CKU7<br />

2 component DOL Starter<br />

2 component REV Starter<br />

Ecombo Starter with CA7<br />

CL7<br />

CLU7<br />

2 component DOL Starter<br />

2 component REV Starter<br />

Ecombo Starter with CA4<br />

CL4<br />

CLU4<br />

T<br />

2 component DOL Starter<br />

2 component REV Starter<br />

Add “T” for 3 component starter<br />

Contactor<br />

Series<br />

Series CA7 ➊<br />

9(C)<br />

12(C)<br />

16(C)<br />

23(C)<br />

30(C)<br />

37(C)<br />

43(C)<br />

60(D)<br />

72(D)<br />

85(D)<br />

Series CA4<br />

9(C)<br />

Aux.<br />

Contact<br />

01 1 NC<br />

10 1 NO<br />

11 1 NO + 1 NC<br />

20 2 NO<br />

22 2 NO + 2 NC<br />

Code<br />

Control Voltage*<br />

AC Voltage<br />

24Z 24V 50/60Hz<br />

120 110V 50Hz / 120V 60Hz<br />

208 208V 60Hz<br />

220W 208…240V 60Hz<br />

277 240V 50Hz / 277V 60Hz<br />

380 380…400V 50Hz / 440V 60Hz<br />

480 440V 50Hz / 480V 60Hz<br />

600 550V 50Hz / 600V 60Hz<br />

Code<br />

12D<br />

24D<br />

24DD<br />

48D<br />

110D<br />

220D<br />

DC Voltage<br />

12V<br />

24V<br />

24V with diode<br />

48V<br />

110V<br />

220V<br />

* Other control voltages available<br />

CL7 - 9 - 10 - 24Z - AS 0.25A - A01<br />

<strong>Circuit</strong> Breaker Type<br />

KT..7<br />

A…<br />

B…<br />

C…<br />

…S<br />

…H<br />

<strong>Motor</strong> Protection<br />

Starter Protection<br />

High Inrush Protection<br />

Standard Performance<br />

High Performance<br />

➊ (C) and (D) designations indicate DC coil.<br />

This illustration is for reference only.<br />

Turn to the appropriate page to determine<br />

specific catalog number & pricing.<br />

Adj. Range<br />

0.16A 0.1…0.16A<br />

0.25A 0.16…0.25A<br />

0.4A 0.25…0.4A<br />

0.63A 0.4…0.63A<br />

1.0A 0.63…1.0A<br />

1.6A 1.0…1.6A<br />

2.5A 1.6…2.5A<br />

4.0A 2.5…4.0A<br />

6.3A 4.0…6.3A<br />

10A 6.3…10A<br />

16A 10…16A<br />

20A 16…20A<br />

25A 20…25A<br />

32A 25…32A<br />

45A 32…45A<br />

Auxiliaries + Trip Contacts<br />

X<br />

A10<br />

A01<br />

A11<br />

A20<br />

T10A01<br />

T10A10<br />

No auxiliary contacts<br />

Aux. Contact 1 NO<br />

Aux. Contact 1 NC<br />

Aux. Contact 1 NO + 1 NC<br />

Aux. Contact 2 NO<br />

1 NO Trip + 1 NC Aux. Contact<br />

1 NO Trip + 1 NO Aux. Contact<br />

Option(s)<br />

For complete listing of<br />

Options Codes, refer to<br />

Modifications page in<br />

this section.<br />

F<br />

<strong>Motor</strong> <strong>Circuit</strong><br />

<strong>Controllers</strong><br />

Ecom<br />

Discount Schedule A-1<br />

F45


Ecombo <strong>Starters</strong><br />

Series CL4<br />

F<br />

<strong>Motor</strong> <strong>Circuit</strong><br />

<strong>Controllers</strong><br />

CL4<br />

Non-Reversing Ecombo <strong>Starters</strong> with AC Coil, Series CA4 Contactor<br />

Thermal Trip<br />

[A]<br />

Non-Reversing Ecombo <strong>Starters</strong> with DC Coil, Series CA4 Contactor<br />

AC Coil Codes (✱)<br />

A.C.<br />

Coil Code<br />

Magnetic Trip<br />

[A]<br />

Voltage Range<br />

50 Hz 60 Hz<br />

24 24V 24V<br />

120 110V 110…120V<br />

240 220…230V 230…240V<br />

277 240V 277V<br />

380 400V-415V 380…400V<br />

Index<br />

➊<br />

Typical Three Phase [HP]<br />

200V 230V 460V 575V Catalog Number ➋ Price<br />

0.10...0.16 2.1 101 ~ ~ ~ ~ CL4-9-10-✱-AS0.16A-X 243<br />

0.16...0.25 3.3 102 ~ ~ ~ ~ CL4-9-10-✱-AS0.25A-X 243<br />

0.25...0.40 5.2 103 ~ ~ ~ ~ CL4-9-10-✱-AS0.4A-X 243<br />

0.40...0.63 8.2 104 ~ ~ ~ ~ CL4-9-10-✱-AS0.63A-X 263<br />

0.63...1 13 105 ~ ~ 1/2 3/4 CL4-9-10-✱-AS1A-X 263<br />

1...1.6 21 106 ~ ~ 3/4 1 CL4-9-10-✱-AS1.6A-X 263<br />

1.6...2.5 33 107 1/2 1/2 1-1/2 2 CL4-9-10-✱-AS2.5A-X 263<br />

2.5...4 52 108 1 1 3 3 CL4-9-10-✱-AS4.0A-X 263<br />

4...6.3 82 109 1-1/2 2 3 5 CL4-9-10-✱-AS6.3A-X 271<br />

6.3...10 130 110 3 3 5 5 CL4-9-10-✱-AS10A-X 271<br />

10…16 208 111 3 3 7-1/2 10 CL4-12-10-✱-AS16A-X 313<br />

Thermal Trip<br />

[A]<br />

Magnetic Trip<br />

[A]<br />

Index<br />

➊<br />

Typical Three Phase [HP]<br />

200V 230V 460V 575V Catalog Number ➋ Price<br />

0.10...0.16 2.1 101 ~ ~ ~ ~ CL4-9C-10-✱-AS0.16A-X 254<br />

0.16...0.25 3.3 102 ~ ~ ~ ~ CL4-9C-10-✱-AS0.25A-X 254<br />

0.25...0.40 5.2 103 ~ ~ ~ ~ CL4-9C-10-✱-AS0.4A-X 254<br />

0.40...0.63 8.2 104 ~ ~ ~ ~ CL4-9C-10-✱-AS0.63A-X 274<br />

0.63...1 13 105 ~ ~ 1/2 3/4 CL4-9C-10-✱-AS1A-X 274<br />

1...1.6 21 106 ~ ~ 3/4 1 CL4-9C-10-✱-AS1.6A-X 274<br />

1.6...2.5 33 107 1/2 1/2 1-1/2 2 CL4-9C-10-✱-AS2.5A-X 274<br />

2.5...4 52 108 1 1 3 3 CL4-9C-10-✱-AS4.0A-X 274<br />

4...6.3 82 109 1-1/2 2 3 5 CL4-9C-10-✱-AS6.3A-X 282<br />

6.3...10 130 110 3 3 5 5 CL4-9C-10-✱-AS10A-X 282<br />

10…16 208 111 3 3 7-1/2 10 CL4-12C-10-✱-AS16A-X 324<br />

Ordering Instructions<br />

Specify Catalog Number<br />

Replace (✱) with Coil Code<br />

DC Coil Codes (✱)<br />

D.C.<br />

Coil Code<br />

24D<br />

48D<br />

110D<br />

220D<br />

See Coil Code table on<br />

this page for codes.<br />

Voltage<br />

24V<br />

110V<br />

220…230V<br />

240V<br />

Includes:<br />

• KTA7-25S (Standard Interrupting<br />

Capacity) <strong>Motor</strong> Controller<br />

• CA4 Contactor<br />

• Connecting Module<br />

(Cat.# <strong>KT7</strong>-25S-PEM12)<br />

• Terminal Adaptor for Type E<br />

Applications (Cat.# <strong>KT7</strong>-25-TE)<br />

• Can mount on one DIN-rail<br />

Horsepower ratings shown in the tables are for reference only.<br />

The final selection of the manual starter depends on the actual<br />

motor full load current and service factor.<br />

• For motor with service factor less than 1.15. Use motor nameplate full load<br />

current times 0.9 and choose the motor starter with the appropriate current<br />

range. Example: <strong>Motor</strong> F.L.C. = 4.2A; S.F. = 1.0. – 4.2A x 0.9 = 3.78A.<br />

Select Catalog Number KTA7-25S-4.0A.<br />

➊ KAIC Assembly Rating Index. See pages F50-51 for Application Rating Guide.<br />

➋ Does not include auxiliary contacts. See Factory Options on page F49 for additional<br />

auxiliary contact configurations.<br />

Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />

F46<br />

Discount Schedule A-1


Reversing Ecombo <strong>Starters</strong><br />

Series CLU4<br />

Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />

Reversing Ecombo <strong>Starters</strong> with AC Coil, Series CA4 Contactor<br />

Thermal Trip<br />

[A]<br />

Magnetic Trip<br />

[A]<br />

AC Coil Codes (✱)<br />

Index<br />

➊<br />

Typical Three Phase [HP]<br />

200V 230V 460V 575V Catalog Number ➋ Price<br />

0.10...0.16 2.1 101 ~ ~ ~ ~ CLU4-9-02-✱-AS0.16A-X 322<br />

0.16...0.25 3.3 102 ~ ~ ~ ~ CLU4-9-02-✱-AS0.25A-X 322<br />

0.25...0.40 5.2 103 ~ ~ ~ ~ CLU4-9-02-✱-AS0.4A-X 322<br />

0.40...0.63 8.2 104 ~ ~ ~ ~ CLU4-9-02-✱-AS0.63A-X 342<br />

0.63...1 13 105 ~ ~ 1/2 3/4 CLU4-9-02-✱-AS1A-X 342<br />

1...1.6 21 106 ~ ~ 3/4 1 CLU4-9-02-✱-AS1.6A-X 342<br />

1.6...2.5 33 107 1/2 1/2 1-1/2 2 CLU4-9-02-✱-AS2.5A-X 342<br />

2.5...4 52 108 1 1 3 3 CLU4-9-02-✱-AS4.0A-X 342<br />

4...6.3 82 109 1-1/2 2 3 5 CLU4-9-02-✱-AS6.3A-X 358<br />

6.3...10 130 110 3 3 5 5 CLU4-9-02-✱-AS10A-X 358<br />

10…16 208 111 3 3 7-1/2 10 CLU4-12-02-✱-AS16A-X 420<br />

A.C.<br />

Coil Code<br />

Voltage Range<br />

50 Hz 60 Hz<br />

24 24V 24V<br />

120 110V 110…120V<br />

240 220…230V 230…240V<br />

277 240V 277V<br />

380 400V-415V 380…400V<br />

Ordering Instructions<br />

Specify Catalog Number<br />

Replace (✱) with Coil Code<br />

See Coil Code table on<br />

this page for codes.<br />

Horsepower ratings shown in the tables are for reference only.<br />

The final selection of the manual starter depends on the actual<br />

motor full load current and service factor.<br />

• For motor with service factor less than 1.15. Use motor nameplate full load<br />

current times 0.9 and choose the motor starter with the appropriate current<br />

range. Example: <strong>Motor</strong> F.L.C. = 4.2A; S.F. = 1.0. – 4.2A x 0.9 = 3.78A.<br />

Select Catalog Number KTA7-25S-4.0A.<br />

Includes:<br />

• KTA7-25S (Standard Interrupting<br />

Capacity) <strong>Motor</strong> Controller<br />

• Two CA4 Contactors<br />

• Connecting Module<br />

(Cat.# <strong>KT7</strong>-25S-PEM12)<br />

• Terminal Adaptor for Type E Applications<br />

(Cat.# <strong>KT7</strong>-25-TE)<br />

• Reversing Power Wiring Kit<br />

(Cat.# KCR4)<br />

• Can mount on one DIN-rail<br />

➊ KAIC Assembly Rating Index. See pages F50-51 for Application Rating Guide.<br />

➋ Does not include auxiliary contacts. See Factory Options on page F49 for additional<br />

auxiliary contact configurations.<br />

F<br />

<strong>Motor</strong> <strong>Circuit</strong><br />

<strong>Controllers</strong><br />

CL4<br />

Discount Schedule A-1<br />

F47


Ecombo <strong>Starters</strong><br />

Series CL7<br />

F<br />

<strong>Motor</strong> <strong>Circuit</strong><br />

<strong>Controllers</strong><br />

CL4<br />

Non-Reversing Ecombo <strong>Starters</strong> with AC Coil, Series CA7 Contactor ➌<br />

Thermal Trip<br />

[A]<br />

Coil Codes (✱) ➋<br />

Magnetic Trip<br />

[A]<br />

Index<br />

➊<br />

Typical Three Phase [HP]<br />

200V 230V 460V 575V<br />

Catalog Number ➋<br />

Price<br />

KTA7-25S — Standard Interrupting Capacity<br />

0.10...0.16 2.1 51 ~ ~ ~ ~ CL7-9-10-✱-AS0.16A-A10 255<br />

0.16...0.25 3.3 52 ~ ~ ~ ~ CL7-9-10-✱-AS0.25A-A10 255<br />

0.25...0.40 5.2 53 ~ ~ ~ ~ CL7-9-10-✱-AS0.4A-A10 255<br />

0.40...0.63 8.2 54 ~ ~ ~ ~ CL7-9-10-✱-AS0.63A-A10 275<br />

0.63...1 13 55 ~ ~ 1/2 3/4 CL7-9-10-✱-AS1A-A10 275<br />

1...1.6 21 56 ~ ~ 1 1 CL7-9-10-✱-AS1.6A-A10 275<br />

1.6...2.5 33 57 1/2 3/4 1-1/2 2 CL7-9-10-✱-AS2.5A-A10 275<br />

2.5...4 52 58 1 1 3 3 CL7-9-10-✱-AS4.0A-A10 275<br />

4...6.3 82 59 1-1/2 2 5 5 CL7-9-10-✱-AS6.3A-A10 275<br />

6.3...10 130 60 3 3 7-1/2 10 CL7-12-10-✱-AS10A-A10 295<br />

10...16 208 61 3 5 10 15 CL7-16-10-✱-AS16A-A10 327<br />

14.5...20 260 64 5 7-1/2 15 15 CL7-23-10-✱-AS20A-A10 340<br />

18.5...25 325 65 5 7-1/2 15 15 CL7-23-10-✱-AS25A-A10 340<br />

KTA7-25H — High Interrupting Capacity<br />

1.6...2.5 33 66 1/2 3/4 1-1/2 2 CL7-9-10-✱-AH2.5A-A10 313<br />

2.5...4 52 68 1 1 3 3 CL7-9-10-✱-AH4.0A-A10 313<br />

4...6.3 82 70 1-1/2 2 5 5 CL7-9-10-✱-AH6.3A-A10 313<br />

6.3...10 130 72 3 3 7-1/2 10 CL7-12-10-✱-AH10A-A10 359<br />

10...16 208 74 3 5 10 15 CL7-16-10-✱-AH16A-A10 370<br />

14.5...20 260 76 5 7-1/2 15 15 CL7-23-10-✱-AH20A-A10 383<br />

18...25 325 78 5 7-1/2 15 15 CL7-23-10-✱-AH25A-A10 383<br />

A.C.<br />

Coil Code<br />

Voltage Range<br />

50 Hz 60 Hz<br />

24Z 24V 24V<br />

120 110V 120V<br />

208 ~ 208V<br />

220W ~ 208V-240V<br />

240 220V 240V<br />

277 240V 277V<br />

380 380...400V 440V<br />

480 440V 480V<br />

600 550V 600V<br />

Ordering Instructions<br />

Specify Catalog Number<br />

Replace (✱) with Coil Code<br />

Horsepower ratings shown in the tables are for reference only.<br />

The final selection of the manual starter depends on the actual<br />

motor full load current and service factor.<br />

• For motor with service factor less than 1.15. Use motor nameplate full load<br />

current times 0.9 and choose the motor starter with the appropriate current<br />

range. Example: <strong>Motor</strong> F.L.C. = 4.2A; S.F. = 1.0. – 4.2A x 0.9 = 3.78A.<br />

Select Catalog Number KTA7-25S-4.0A.<br />

See Coil Code table on<br />

this page for codes.<br />

Includes:<br />

• <strong>KT7</strong> <strong>Motor</strong> Controller with 1 NO<br />

Auxiliary Contact<br />

• CA7 Contactor (AC)<br />

• Connecting Module<br />

(Cat.# <strong>KT7</strong>-25[S or H]-PEC23)<br />

• Terminal Adaptor for Type E<br />

Applications (Cat.# <strong>KT7</strong>-25-TE)<br />

• Can mount on one DIN-rail<br />

➊ KAIC Assembly Rating Index. See pages F50-51 for Application Rating Guide.<br />

➋ Other voltages available, see Section A in this catalog. Nonstandard coil voltages<br />

not listed here must be ordered and installed separately as renewal parts.<br />

➌ CL7-30, 37 & 43 not shown because the components must be unassembled to<br />

mount them on two DIN-rails.<br />

Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />

F48<br />

Discount Schedule A-1


Reversing Ecombo <strong>Starters</strong><br />

Series CLU7<br />

Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />

Reversing Ecombo <strong>Starters</strong> with AC Coil, Series CA7 Contactor ➌<br />

Thermal Trip<br />

[A]<br />

Magnetic<br />

Trip [A]<br />

Coil Codes (✱) ➋<br />

Index<br />

➊<br />

Typical Three Phase [HP]<br />

200V 230V 460V 575V<br />

Catalog Number ➋<br />

Price<br />

KTA7-25S — Standard Interrupting Capacity<br />

0.10...0.16 2.1 51 ~ ~ ~ ~ CLU7-9-22-✱-AS0.16A-A10 386<br />

0.16...0.25 3.3 52 ~ ~ ~ ~ CLU7-9-22-✱-AS0.25A-A10 386<br />

0.25...0.40 5.2 53 ~ ~ ~ ~ CLU7-9-22-✱-AS0.4A-A10 386<br />

0.40...0.63 8.2 54 ~ ~ ~ ~ CLU7-9-22-✱-AS0.63A-A10 406<br />

0.63...1 13 55 ~ ~ 1/2 3/4 CLU7-9-22-✱-AS1A-A10 406<br />

1...1.6 21 56 ~ ~ 1 1 CLU7-9-22-✱-AS1.6A-A10 406<br />

1.6...2.5 33 57 1/2 3/4 1-1/2 2 CLU7-9-22-✱-AS2.5A-A10 406<br />

2.5...4 52 58 1 1 3 3 CLU7-9-22-✱-AS4.0A-A10 406<br />

4...6.3 82 59 1-1/2 2 5 5 CLU7-9-22-✱-AS6.3A-A10 406<br />

6.3...10 130 60 3 3 7-1/2 10 CLU7-12-22-✱-AS10A-A10 445<br />

10...16 208 61 3 5 10 15 CLU7-16-22-✱-AS16A-A10 490<br />

14.5...20 260 64 5 7-1/2 15 15 CLU7-23-22-✱-AS20A-A10 515<br />

18.5...25 325 65 5 7-1/2 15 15 CLU7-23-22-✱-AS25A-A10 515<br />

KTA7-25H — High Interrupting Capacity<br />

1.6...2.5 33 66 1/2 3/4 1-1/2 2 CLU7-9-22-✱-AH2.5A-A10 443<br />

2.5...4 52 68 1 1 3 3 CLU7-9-22-✱-AH4.0A-A10 443<br />

4...6.3 82 70 1-1/2 2 5 5 CLU7-9-22-✱-AH6.3A-A10 443<br />

6.3...10 130 72 3 3 7-1/2 10 CLU7-12-22-✱-AH10A-A10 509<br />

10...16 208 74 3 5 10 15 CLU7-16-22-✱-AH16A-A10 533<br />

14.5...20 260 76 5 7-1/2 15 15 CLU7-23-22-✱-AH20A-A10 558<br />

18...25 325 78 5 7-1/2 15 15 CLU7-23-22-✱-AH25A-A10 558<br />

A.C.<br />

Coil Code<br />

Voltage Range<br />

50 Hz 60 Hz<br />

24Z 24V 24V<br />

120 110V 120V<br />

208 ~ 208V<br />

220W ~ 208V-240V<br />

240 220V 240V<br />

277 240V 277V<br />

380 380...400V 440V<br />

480 440V 480V<br />

600 550V 600V<br />

Ordering Instructions<br />

Specify Catalog Number<br />

Replace (✱) with Coil Code<br />

Horsepower ratings shown in the tables are for reference only.<br />

The final selection of the manual starter depends on the actual<br />

motor full load current and service factor.<br />

• For motor with service factor less than 1.15. Use motor nameplate full load<br />

current times 0.9 and choose the motor starter with the appropriate current<br />

range. Example: <strong>Motor</strong> F.L.C. = 4.2A; S.F. = 1.0. – 4.2A x 0.9 = 3.78A.<br />

Select Catalog Number KTA7-25S-4.0A.<br />

See Coil Code table on<br />

this page for codes.<br />

Includes:<br />

• <strong>KT7</strong> <strong>Motor</strong> Controller with 1 NO<br />

Auxiliary Contact<br />

• Two CA7 Contactors (AC)<br />

• Connecting Module<br />

(Cat.# <strong>KT7</strong>-25[S or H]-PEC23)<br />

• Terminal Adaptor for Type E Applications<br />

(Cat.# <strong>KT7</strong>-25-TE)<br />

• Reversing Power Wiring Kit<br />

(Cat.# CAUT7-PW23)<br />

• <strong>Electric</strong>al / Mechanical Interlock<br />

(Cat.# CM7-02)<br />

• Can mount on one DIN-rail<br />

➊ KAIC Assembly Rating Index. See pages F50-51 for Application Rating Guide.<br />

➋ Other voltages available, see Section A in this catalog. Nonstandard coil voltages<br />

not listed here must be ordered and installed separately as renewal parts.<br />

➌ CLU7-30, 37 & 43 not shown because the components must be unassembled to<br />

mount them on two DIN-rails.<br />

F<br />

<strong>Motor</strong> <strong>Circuit</strong><br />

<strong>Controllers</strong><br />

CL4<br />

Discount Schedule A-1<br />

F49


EcomboPlus <strong>Starters</strong>, AC Coil<br />

Series CK7<br />

F<br />

<strong>Motor</strong> <strong>Circuit</strong><br />

<strong>Controllers</strong><br />

CK7<br />

Non-Reversing EcomboPlus <strong>Starters</strong> with AC Coil, Series CA7 Contactors<br />

Thermal Trip Magnetic Trip Index<br />

Typical Three Phase [HP]<br />

[A]<br />

[A] ➊ 200V 230V 460V 575V Catalog Number ➋ Price<br />

KTA7-25S — Standard Interrupting Capacity<br />

0.10...0.16 2.1 1 ~ ~ ~ ~ CK7-9-10-✱-AS0.16A-A11 351<br />

0.16...0.25 3.3 2 ~ ~ ~ ~ CK7-9-10-✱-AS0.25A-A11 351<br />

0.25...0.40 5.2 3 ~ ~ ~ ~ CK7-9-10-✱-AS0.4A-A11 351<br />

0.40...0.63 8.2 4 ~ ~ ~ ~ CK7-9-10-✱-AS0.63A-A11 371<br />

0.63...1 13 5 ~ ~ 1/2 3/4 CK7-9-10-✱-AS1A-A11 371<br />

1...1.6 21 6 ~ ~ 1 1 CK7-9-10-✱-AS1.6A-A11 371<br />

1.6...2.5 33 7 1/2 3/4 1-1/2 2 CK7-9-10-✱-AS2.5A-A11 371<br />

2.5...4 52 8 1 1 3 3 CK7-9-10-✱-AS4A-A11 371<br />

4...6.3 82 9 1-1/2 2 5 5 CK7-9-10-✱-AS6.3A-A11 371<br />

6.3...10 130 10 3 3 7-1/2 10 CK7-12-10-✱-AS10A-A11 392<br />

10...16 208 11 3 5 10 15 CK7-16-10-✱-AS16A-A11 426<br />

14.5...20 260 14 5 7-1/2 15 15 CK7-23-10-✱-AS20A-A11 439<br />

18.5...25 325 15 5 7-1/2 15 15 CK7-23-10-✱-AS25A-A11 439<br />

KTA7-25H — High Interrupting Capacity<br />

1.6...2.5 33 16 1/2 3/4 1-1/2 2 CK7-9-10-✱-AH2.5A-A11 411<br />

2.5...4 52 18 1 1 3 3 CK7-9-10-✱-AH4A-A11 411<br />

4...6.3 82 20 1-1/2 2 5 5 CK7-9-10-✱-AH6.3A-A11 411<br />

6.3...10 130 22 3 3 7-1/2 10 CK7-12-10-✱-AH10A-A11 459<br />

10...16 208 24 3 5 10 15 CK7-16-10-✱-AH16A-A11 471<br />

14.5...20 260 26 5 7-1/2 15 15 CK7-23-10-✱-AH20A-A11 484<br />

18...25 325 28 5 7-1/2 15 15 CK7-23-10-✱-AH25A-A11 484<br />

KTA7-45H — High Interrupting Capacity<br />

6.3…10 130 30 3 3 7-1/2 10 CK7-30-11-✱-AH10A-A11 632<br />

10....16 208 31 3 5 10 15 CK7-30-11-✱-AH16A-A11 632<br />

14.5...20 260 32 5 7-1/2 15 15 CK7-30-11-✱-AH20A-A11 632<br />

18…25 325 33 5 7-1/2 15 15 CK7-30-11-✱-AH25A-A11 632<br />

23…32 416 34 7-1/2 10 20 25 CK7-30-11-✱-AH32A-A11 650<br />

32…45 585 35 10 10 25 30 CK7-37-11-✱-AH45A-A11 689<br />

32…45 585 36 10 15 30 30 CK7-43-11-✱-AH45A-A11 696<br />

Coil Codes (✱) ➍<br />

A.C.<br />

Coil Code<br />

Voltage Range<br />

50 Hz 60 Hz<br />

24Z 24V 24V<br />

120 110V 120V<br />

208 ~ 208V<br />

220W ~ 208V-240V<br />

240 220V 240V<br />

277 240V 277V<br />

380 380...400V 440V<br />

480 440V 480V<br />

600 550V 600V<br />

Ordering Instructions<br />

Specify Catalog Number<br />

Replace (✱) with Coil Code<br />

Horsepower ratings shown in the tables are for reference only.<br />

The final selection of the manual starter depends on the actual<br />

motor full load current and service factor.<br />

• For motor with service factor less than 1.15. Use motor nameplate full load<br />

current times 0.9 and choose the motor starter with the appropriate current<br />

range. Example: <strong>Motor</strong> F.L.C. = 4.2A; S.F. = 1.0. – 4.2A x 0.9 = 3.78A.<br />

Select Catalog Number KTA7-25S-4.0A.<br />

See Coil Code table on<br />

this page for codes.<br />

Description ➌<br />

The EcomboPlus starter is a<br />

factory assembly consisting of a <strong>KT7</strong><br />

controller with 1 NO - 1 NC auxiliary<br />

and a CA7 contactor housed in a<br />

specially designed frame. All control<br />

wiring is pre-wired and brought out<br />

to a built-in terminal block, integral<br />

to the mounting frame. Terminal<br />

Adaptor (Cat.# <strong>KT7</strong>-25[45]-TE) is also<br />

included for Type E applications.<br />

➊ KAIC Assembly Rating Index. See pages F50-51 for Application Rating Guide.<br />

➋ 1 NO + 1 NC auxiliary contact on <strong>KT7</strong> is standard. 1 NO auxiliary contact on CA7<br />

contactor is standard. See Factory Options on page F49 for additional auxiliary<br />

contact configurations.<br />

➌ Mounting Options:<br />

• Screw Fixing<br />

• Snap Fixing on (1) or (2) 35 mm DIN Rails<br />

• Snap Fixing on (1) 75 mm DIN Rail<br />

➍ Other voltages available, see Section A in this catalog. Nonstandard coil voltages<br />

not listed here must be ordered and installed separately as renewal parts.<br />

Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />

F50<br />

Discount Schedule A-1


Reversing EcomboPlus <strong>Starters</strong>, AC Coil<br />

Series CKU7<br />

Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />

Reversing EcomboPlus <strong>Starters</strong> with AC Coil, Series CA7 Contactors<br />

Thermal Trip<br />

[A]<br />

Coil Codes (✱) ➍<br />

Magnetic Trip<br />

[A]<br />

Typical Three Phase [HP]<br />

Index<br />

➊ 200V 230V 460V 575V Catalog Number ➋<br />

KTA7-25S — Standard Interrupting Capacity<br />

0.10...0.16 2.1 1 ~ ~ ~ ~ CKU7-9-22-✱-AS0.16A-A11 531<br />

0.16...0.25 3.3 2 ~ ~ ~ ~ CKU7-9-22-✱-AS0.25A-A11 531<br />

0.25...0.40 5.2 3 ~ ~ ~ ~ CKU7-9-22-✱-AS0.4A-A11 531<br />

0.40...0.63 8.2 4 ~ ~ ~ ~ CKU7-9-22-✱-AS0.63A-A11 531<br />

0.63...1 13 5 ~ ~ 1/2 3/4 CKU7-9-22-✱-AS1A-A11 531<br />

1...1.6 21 6 ~ ~ 1 1 CKU7-9-22-✱-AS1.6A-A11 531<br />

1.6...2.5 33 7 1/2 3/4 1-1/2 2 CKU7-9-22-✱-AS2.5A-A11 531<br />

2.5...4 52 8 1 1 3 3 CKU7-9-22-✱-AS4.0A-A11 531<br />

4...6.3 82 9 1-1/2 2 5 5 CKU7-9-22-✱-AS6.3A-A11 551<br />

6.3...10 130 10 3 3 7-1/2 10 CKU7-12-22-✱-AS10A-A11 593<br />

10...16 208 11 3 5 10 15 CKU7-16-22-✱-AS16A-A11 639<br />

14.5...20 260 14 5 7-1/2 15 15 CKU7-23-22-✱-AS20A-A11 665<br />

18.5...25 325 15 5 7-1/2 15 15 CKU7-23-22-✱-AS25A-A11 665<br />

KTA7-25H — High Interrupting Capacity<br />

1.6...2.5 33 16 1/2 3/4 1-1/2 2 CKU7-9-22-✱-AH2.5A-A11 591<br />

2.5...4 52 18 1 1 3 3 CKU7-9-22-✱-AH4.0A-A11 591<br />

4...6.3 82 20 1-1/2 2 5 5 CKU7-9-22-✱-AH6.3A-A11 591<br />

6.3...10 130 22 3 3 7-1/2 10 CKU7-12-22-✱-AH10A-A11 659<br />

10...16 208 24 3 5 10 15 CKU7-16-22-✱-AH16A-A11 684<br />

14.5...20 260 26 5 7-1/2 15 15 CKU7-23-22-✱-AH20A-A11 710<br />

18...25 325 28 5 7-1/2 15 15 CKU7-23-22-✱-AH25A-A11 710<br />

Horsepower ratings shown in the tables are for reference only.<br />

The final selection of the manual starter depends on the actual<br />

motor full load current and service factor.<br />

• For motor with service factor less than 1.15. Use motor nameplate full load<br />

current times 0.9 and choose the motor starter with the appropriate current<br />

range. Example: <strong>Motor</strong> F.L.C. = 4.2A; S.F. = 1.0. – 4.2A x 0.9 = 3.78A.<br />

Select Catalog Number KTA7-25S-4.0A.<br />

A.C.<br />

Coil Code<br />

Voltage Range<br />

50 Hz 60 Hz<br />

24Z 24V 24V<br />

120 110V 120V<br />

208 ~ 208V<br />

220W ~ 208V-240V<br />

240 220V 240V<br />

277 240V 277V<br />

380 380...400V 440V<br />

480 440V 480V<br />

600 550V 600V<br />

Ordering Instructions<br />

Specify Catalog Number<br />

Replace (✱) with Coil Code<br />

See Coil Code table on<br />

this page for codes.<br />

Price<br />

Description ➌<br />

The EcomboPlus Reversing starter<br />

is a factory assembly consisting of<br />

a <strong>KT7</strong> controller with 1 NO - 1 NC<br />

auxiliary and reversing CA7 contactors<br />

housed in a specially designed<br />

frame. All control wiring is pre-wired<br />

and brought out to a built-in terminal<br />

block, integral to the mounting frame.<br />

A Reversing Power Wiring Kit (Cat.#<br />

CAUT7-PW23) is used to wire the reversing<br />

contactors. An electrical and<br />

mechanical interlock is also provided<br />

(Cat.# CM7-02), as well as a Terminal<br />

Adaptor (Cat.# <strong>KT7</strong>-25-TE) for Type E<br />

applications.<br />

➊ KAIC Assembly Rating Index. See pages F50-51 for Application Rating Guide.<br />

➋ 1 NO + 1 NC auxiliary contact on the <strong>KT7</strong> is standard. 2-NO auxiliary contacts<br />

on the CKU7 contactor and 2-NC auxiliary contacts on the CM7-02 interlock per<br />

reversing pair is standard. See Factory Options on page F49 for additional auxiliary<br />

contact configurations.<br />

➌ Mounting Options:<br />

• Screw Fixing<br />

• Snap Fixing on (1) or (2) 35 mm DIN Rails<br />

• Snap Fixing on (1) 75 mm DIN Rail<br />

➍ Other voltages available, see Section A in this catalog. Nonstandard coil voltages<br />

not listed here must be ordered and installed separately as renewal parts.<br />

F<br />

<strong>Motor</strong> <strong>Circuit</strong><br />

<strong>Controllers</strong><br />

CK7<br />

Discount Schedule A-1<br />

F51


EcomboPlus <strong>Starters</strong>, DC Coil<br />

Series CK7<br />

F<br />

<strong>Motor</strong> <strong>Circuit</strong><br />

<strong>Controllers</strong><br />

CK7<br />

Non-Reversing EcomboPlus <strong>Starters</strong> with DC Coil, Series CA7 Contactors<br />

Thermal Trip<br />

[A]<br />

Coil Codes (✱) ➍<br />

Magnetic Trip<br />

[A]<br />

Typical Three Phase [HP]<br />

Index<br />

➊ 200V 230V 460V 575V Catalog Number ➋<br />

KTA7-25S — Standard Interrupting Capacity<br />

0.10...0.16 2.1 1 ~ ~ ~ ~ CK7-9C-10-✱-AS0.16A-A11 384<br />

0.16...0.25 3.3 2 ~ ~ ~ ~ CK7-9C-10-✱-AS0.25A-A11 384<br />

0.25...0.40 5.2 3 ~ ~ ~ ~ CK7-9C-10-✱-AS0.4A-A11 384<br />

0.40...0.63 8.2 4 ~ ~ ~ ~ CK7-9C-10-✱-AS0.63A-A11 404<br />

0.63...1 13 5 ~ ~ 1/2 3/4 CK7-9C-10-✱-AS1A-A11 404<br />

1...1.6 21 6 ~ ~ 1 1 CK7-9C-10-✱-AS1.6A-A11 404<br />

1.6...2.5 33 7 1/2 3/4 1-1/2 2 CK7-9C-10-✱-AS2.5A-A11 404<br />

2.5...4 52 8 1 1 3 3 CK7-9C-10-✱-AS4.0A-A11 404<br />

4...6.3 82 9 1-1/2 2 5 5 CK7-9C-10-✱-AS6.3A-A11 404<br />

6.3...10 130 10 3 3 7-1/2 10 CK7-12C-10-✱-AS10A-A11 431<br />

10...16 208 11 3 5 10 15 CK7-16C-10-✱-AS16A-A11 467<br />

14.5...20 260 14 5 7-1/2 15 15 CK7-23C-10-✱-AS20A-A11 483<br />

18.5...25 325 15 5 7-1/2 15 15 CK7-23C-10-✱-AS25A-A11 483<br />

KTA7-25H — High Interrupting Capacity<br />

1.6...2.5 33 16 1/2 3/4 1-1/2 2 CK7-9C-10-✱-AH2.5A-A11 436<br />

2.5...4 52 18 1 1 3 3 CK7-9C-10-✱-AH4.0A-A11 436<br />

4...6.3 82 20 1-1/2 2 5 5 CK7-9C-10-✱-AH6.3A-A11 436<br />

6.3...10 130 22 3 3 7-1/2 10 CK7-12C-10-✱-AH10A-A11 490<br />

10...16 208 24 3 5 10 15 CK7-16C-10-✱-AH16A-A11 505<br />

14.5...20 260 26 5 7-1/2 15 15 CK7-23C-10-✱-AH20A-A11 527<br />

18...25 325 28 5 7-1/2 15 15 CK7-23C-10-✱-AH25A-A11 527<br />

KTA7-45H — High Interrupting Capacity<br />

6.3…10 130 30 3 3 7-1/2 10 CK7-30C-11-✱-AH10A-A11 698<br />

10....16 208 31 3 5 10 15 CK7-30C-11-✱-AH16A-A11 698<br />

14.5...20 260 32 5 7-1/2 15 15 CK7-30C-11-✱-AH20A-A11 698<br />

18…25 325 33 5 7-1/2 15 15 CK7-30C-11-✱-AH25A-A11 698<br />

23…32 416 34 7-1/2 10 20 25 CK7-30C-11-✱-AH32A-A11 735<br />

32…45 585 35 10 10 25 30 CK7-37C-11-✱-AH45A-A11 772<br />

32…45 585 36 10 15 30 30 CK7-43C-11-✱-AH45A-A11 785<br />

CK7-9C...43C<br />

D.C. Coil Code<br />

12D<br />

24D<br />

48D<br />

110D<br />

220D<br />

Voltage<br />

12V<br />

24V<br />

48V<br />

110V<br />

220V<br />

Ordering Instructions<br />

Specify Catalog Number<br />

Replace (✱) with Coil Code<br />

Price<br />

Horsepower ratings shown in the tables are for reference only.<br />

The final selection of the manual starter depends on the actual<br />

motor full load current and service factor.<br />

• For motor with service factor less than 1.15. Use motor nameplate full load<br />

current times 0.9 and choose the motor starter with the appropriate current<br />

range. Example: <strong>Motor</strong> F.L.C. = 4.2A; S.F. = 1.0. – 4.2A x 0.9 = 3.78A.<br />

Select Catalog Number KTA7-25S-4.0A.<br />

See Coil Code table on<br />

this page for codes.<br />

Description ➌<br />

The EcomboPlus starter is a factory<br />

assembly consisting of a <strong>KT7</strong><br />

controller with 1 NO - 1 NC auxiliary<br />

and a CA7 contactor housed in a<br />

specially designed frame. All control<br />

wiring is pre-wired and brought out<br />

to a built-in terminal block, integral<br />

to the mounting frame. Terminal<br />

Adaptor (Cat.# <strong>KT7</strong>-25[45]-TE) is also<br />

included for Type E applications.<br />

➊ KAIC Assembly Rating Index. See pages F50-51 for Application Rating Guide.<br />

➋ 1 NO + 1 NC auxiliary contact on the <strong>KT7</strong> is standard. 2-NO auxiliary contacts<br />

on the CAU7 contactor and 2-NC auxiliary contacts on the CM7-02 interlock per<br />

reversing pair is standard. See Factory Options on page F49 for additional auxiliary<br />

contact configurations.<br />

➌ Mounting Options:<br />

• Screw Fixing<br />

• Snap Fixing on (1) or (2) 35 mm DIN Rails<br />

• Snap Fixing on (1) 75 mm DIN Rail<br />

➍ Other voltages available, see Section A in this catalog. Nonstandard coil voltages<br />

not listed here must be ordered and installed separately as renewal parts.<br />

Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />

F52<br />

Discount Schedule A-1


Factory Options<br />

Series CK7<br />

CL4 and CL7 Modifications<br />

CK7 Modifications<br />

Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />

Modification<br />

Change Last<br />

Digit in Catalog<br />

Number to: ➊<br />

CL4 and CL7 Additions<br />

Add desired suffix AFTER auxiliary contact option code.<br />

Price<br />

<strong>KT7</strong> Auxiliary and Trip Contacts<br />

Auxiliary Contact 1 NO (CL4 only) A10 33<br />

Auxiliary Contact 1 NC A01 33<br />

Auxiliary Contact 1 NO + 1 NC A11 37<br />

Auxiliary Contact 2 NO A20 37<br />

1 NO Trip + 1 NC Auxiliary Contact T10A01 47<br />

1 NO Trip + 1 NO Auxiliary Contact T10A10 47<br />

Addition<br />

Add Suffix to<br />

Catalog Number: Price<br />

Accessories<br />

Electronic Interfaces (CA7) -JE 56<br />

Surge Suppressor RC (CA7) -R 32<br />

Surge Suppressor Varistor (CA7) -V 24<br />

Surge Suppressor Diode (CA7) -D 31<br />

Lockable Twist Knob (<strong>KT7</strong>) - Black -KN 16<br />

Lockable Twist Knob (<strong>KT7</strong>) - Red/Yellow -KRY 20<br />

Additional Contactor Auxiliaries (Side Mount)<br />

1 NC -S01 27<br />

1 NO -S10 27<br />

1 NO + 1 NC -S11 34<br />

2 NO -S20 34<br />

Additional Contactor Auxiliaries (Front Mount)<br />

1 NO + 1 NC -F11 34<br />

2 NO -F20 34<br />

2 NO + 2 NC -F22 34<br />

Additional <strong>KT7</strong> Auxiliaries (Side Mount)<br />

2 NC -AS02 47<br />

2 NO -AS20 47<br />

1 NO + 1 NC -AS11 47<br />

Additional <strong>KT7</strong> Trip Contacts (Side Mount)<br />

1 NO Thermal-Mag + 1 NO Mag Only -R00 56<br />

1 NO Thermal-Mag + 1 NC Mag Only -R01 56<br />

1 NC Thermal-Mag + 1 NO Mag Only -R10 56<br />

1 NC Thermal-Mag + 1 NC Mag Only -R11 56<br />

1 NO Mag Only + 1 NC Mag Only -M11 56<br />

➊ For CL4, change last digit “X” to one of the modifications listed. Example: Change<br />

CL4-9-10-✱-AS0.16A-X to CL4-9-10-✱-AS0.16A-A10. For CL7, change last digits<br />

“A10” to one of the modifications listed. Example: Change CL7-9-10- * -AS0.16A-<br />

A10 to CL7-9-10-✱-AS0.16A-A01.<br />

Modification<br />

Change Last Digits<br />

(A11) in Catalog<br />

Number to: ➊<br />

CK7 Additions<br />

Add desired suffix AFTER auxiliary contact option code.<br />

Price<br />

CK7 Auxiliary and Trip Contacts<br />

Auxiliary Contact 2 NO A20 31<br />

1 NO Trip + 1 NC Auxiliary Contact T10A01 10<br />

1 NO Trip + 1 NO Auxiliary Contact T10A10 10<br />

Addition<br />

Add Suffix to<br />

Catalog Number:<br />

Price<br />

Accessories<br />

Electronic Interfaces (CA7) -JE 56<br />

Surge Suppressor RC (CA7) -R 32<br />

Surge Suppressor Varistor (CA7) -V 24<br />

Surge Suppressor Diode (CA7) -D 31<br />

Socket and Plug for Control <strong>Circuit</strong> -SP 27<br />

Lockable Twist Knob (<strong>KT7</strong>) - Black -KN 16<br />

Lockable Twist Knob (<strong>KT7</strong>) - Red/Yellow -KRY 20<br />

Additional Contactor Auxiliaries (Side Mount)<br />

1 NC -S01 27<br />

1 NO -S10 27<br />

1 NO + 1 NC -S11 34<br />

2 NO -S20 34<br />

Additional <strong>KT7</strong> Auxiliaries (Side Mount)<br />

2 NC -AS02 47<br />

2 NO -AS20 47<br />

1 NO + 1 NC -AS11 47<br />

Additional <strong>KT7</strong> Trip Contacts (Side Mount)<br />

1 NO Thermal-Mag + 1 NO Mag Only -R00 56<br />

1 NO Thermal-Mag + 1 NC Mag Only -R01 56<br />

1 NC Thermal-Mag + 1 NO Mag Only -R10 56<br />

1 NC Thermal-Mag + 1 NC Mag Only -R11 56<br />

1 NO Mag Only+ 1 NC Mag Only -M11 56<br />

F<br />

<strong>Motor</strong> <strong>Circuit</strong><br />

<strong>Controllers</strong><br />

Ecom<br />

Discount Schedule A-1<br />

F53


Technical Information<br />

Short <strong>Circuit</strong> Ratings<br />

<strong>KT7</strong> Assembly – Application Rating Chart (Ratings are dependent on type of application)<br />

F<br />

<strong>Motor</strong> <strong>Circuit</strong><br />

<strong>Controllers</strong><br />

Rating<br />

Index<br />

Assembly<br />

Assembly Components<br />

<strong>Manual</strong> Controller<br />

or<br />

Group Installation<br />

480Y / 227V<br />

Combination<br />

<strong>Motor</strong> Controller<br />

(Type F)<br />

600Y / 347V<br />

Self-Protected<br />

Combination <strong>Motor</strong><br />

Controller (Type E)<br />

<strong>KT7</strong> Contactor 480V KAIC 600V KAIC Type 1 KAIC Type 2 KAIC Type 1 KAIC Type 2 KAIC Type E KAIC Type E KAIC<br />

CL4 / CLU4 UL Assembly<br />

101 CL4 / CLU4 KTA7-25S-0.16A CA4-9 65 47 65 65 47 ~ ~ ~<br />

102 CL4 / CLU4 KTA7-25S-0.25A CA4-9 65 47 65 65 47 ~ ~ ~<br />

103 CL4 / CLU4 KTA7-25S-0.4A CA4-9 65 47 65 65 47 ~ ~ ~<br />

104 CL4 / CLU4 KTA7-25S-0.63A CA4-9 65 47 65 65 47 ~ ~ ~<br />

105 CL4 / CLU4 KTA7-25S-1.0A CA4-9 65 47 65 65 47 ~ ~ ~<br />

106 CL4 / CLU4 KTA7-25S-1.6A CA4-9 65 47 65 65 47 ~ ~ ~<br />

107 CL4 / CLU4 KTA7-25S-2.5A CA4-9 65 30 65 ~ 30 ~ ~ ~<br />

108 CL4 / CLU4 KTA7-25S-4.0A CA4-9 65 30 65 ~ 30 ~ ~ ~<br />

109 CL4 / CLU4 KTA7-25S-6.3A CA4-9 65 ~ 65 ~ ~ ~ ~ ~<br />

110 CL4 / CLU4 KTA7-25S-10A CA4-9 65 ~ 65 ~ ~ ~ ~ ~<br />

111 CL4 / CLU4 KTA7-25S-16A CA4-12 30 ~ 30 ~ ~ ~ ~ ~<br />

CL7 / CLU7 UL Assembly<br />

51 CL7 / CLU7 KTA7-25S-0.16A CA7-9 65 47 65 65 47 47 65 47<br />

52 CL7 / CLU7 KTA7-25S-0.25A CA7-9 65 47 65 65 47 47 65 47<br />

53 CL7 / CLU7 KTA7-25S-0.4A CA7-9 65 47 65 65 47 47 65 47<br />

54 CL7 / CLU7 KTA7-25S-0.63A CA7-9 65 47 65 65 47 47 65 47<br />

55 CL7 / CLU7 KTA7-25S-1.0A CA7-9 65 47 65 65 47 47 65 47<br />

56 CL7 / CLU7 KTA7-25S-1.6A CA7-9 65 47 65 65 47 47 65 47<br />

57 CL7 / CLU7 KTA7-25S-2.5A CA7-9 65 30 65 65 30 10 65 ~<br />

58 CL7 / CLU7 KTA7-25S-4.0A CA7-9 65 30 65 ~ 30 ~ ~ ~<br />

59 CL7 / CLU7 KTA7-25S-6.3A CA7-9 65 30 65 ~ ~ ~ ~ ~<br />

60 CL7 / CLU7 KTA7-25S-10A CA7-12 65 30 65 ~ ~ ~ ~ ~<br />

61 CL7 / CLU7 KTA7-25S-16A CA7-16 30 30 30 ~ ~ ~ ~ ~<br />

62 CL7 / CLU7 KTA7-25H-4.0A CA7-23 65 30 65 ~ 30 ~ 65 30<br />

63 CL7 / CLU7 KTA7-25H-16A CA7-23 30 30 65 ~ ~ ~ ~ ~<br />

64 CL7 / CLU7 KTA7-25S-20A CA7-23 30 30 10 ~ ~ ~ ~ ~<br />

65 CL7 / CLU7 KTA7-25S-25A CA7-23 30 30 ~ ~ ~ ~ ~ ~<br />

66 CL7 / CLU7 KTA7-25H-2.5A CA7-9 65 30 65 65 30 ~ 65 ~<br />

67 CL7 / CLU7 KTA7-25H-2.5A CA7-23 65 30 65 65 30 30 65 30<br />

68 CL7 / CLU7 KTA7-25H-4.0A CA7-9 65 30 65 65 30 ~ ~ ~<br />

69 CL7 / CLU7 KTA7-25H-4.0A CA7-23 65 30 65 65 30 30 65 30<br />

70 CL7 / CLU7 KTA7-25H-6.3A CA7-9 65 30 65 65 30 ~ ~ ~<br />

71 CL7 KTA7-25H-6.3A CA7-30 65 30 65 65 30 30 65 30<br />

72 CL7 / CLU7 KTA7-25H-10A CA7-12 65 30 65 65 30 ~ ~ ~<br />

73 CL7 KTA7-25H-10A CA7-30 65 30 65 65 30 30 65 30<br />

74 CL7 / CLU7 KTA7-25H-16A CA7-16 65 30 65 65 30 ~ ~ ~<br />

75 CL7 KTA7-25H-16A CA7-30 65 30 65 65 30 30 65 30<br />

76 CL7 / CLU7 KTA7-25H-20A CA7-23 65 30 65 65 ~ ~ ~ ~<br />

77 CL7 KTA7-25H-20A CA7-30 65 30 65 65 ~ ~ 65 ~<br />

78 CL7 / CLU7 KTA7-25H-25A CA7-23 30 30 65 65 ~ ~ ~ ~<br />

79 CL7 KTA7-25H-25A CA7-30 65 30 65 65 30 30 65 30<br />

80 CL7 KTA7-45H-10A CA7-30 65 30 65 65 30 30 65 30<br />

81 CL7 KTA7-45H-16A CA7-30 65 30 65 65 30 30 65 30<br />

82 CL7 KTA7-45H-20A CA7-30 65 30 65 65 30 30 65 30<br />

83 CL7 KTA7-45H-25A CA7-30 65 30 65 65 30 30 65 30<br />

84 CL7 KTA7-45H-45A CA7-37 65 18 65 65 ~ ~ 65 ~<br />

85 CL7 KTA7-45H-45A CA7-45 65 18 65 65 ~ ~ 65 ~<br />

480Y /<br />

277V<br />

600Y /<br />

347V<br />

Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />

Ecom<br />

Gray type indicates non-cataloged assembly. Contact your<br />

Sprecher+ Schuh representative for information.<br />

F54<br />

Discount Schedule A-1


Technical Information<br />

Short <strong>Circuit</strong> Ratings<br />

Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />

<strong>KT7</strong> Assembly – Application Rating Chart (Ratings are dependent on type of application)<br />

Rating<br />

Index<br />

Assembly<br />

Assembly Components<br />

Gray type indicates non-cataloged assembly. Contact your<br />

Sprecher+ Schuh representative for information.<br />

<strong>Manual</strong> Controller<br />

or<br />

Group Installation<br />

480Y / 227V<br />

Combination<br />

<strong>Motor</strong> Controller<br />

(Type F)<br />

600Y / 347V<br />

Self-Protected<br />

Combination <strong>Motor</strong><br />

Controller (Type E)<br />

<strong>KT7</strong> Contactor 480V KAIC 600V KAIC Type 1 KAIC Type 2 KAIC Type 1 KAIC Type 2 KAIC Type E KAIC Type E KAIC<br />

CK7 / CKU7 UL Assembly<br />

1 CK7/CKU7 KTA7-25S-0.16A CA7-9 65 47 65 65 47 47 65 47<br />

2 CK7/CKU7 KTA7-25S-0.25A CA7-9 65 47 65 65 47 47 65 47<br />

3 CK7/CKU7 KTA7-25S-0.4A CA7-9 65 47 65 65 47 47 65 47<br />

4 CK7/CKU7 KTA7-25S-0.63A CA7-9 65 47 65 65 47 47 65 47<br />

5 CK7/CKU7 KTA7-25S-1.0A CA7-9 65 47 65 65 47 47 65 47<br />

6 CK7/CKU7 KTA7-25S-1.6A CA7-9 65 47 65 65 47 47 65 47<br />

7 CK7/CKU7 KTA7-25S-2.5A CA7-9 65 30 65 65 30 10 65 ~<br />

8 CK7/CKU7 KTA7-25S-4.0A CA7-9 65 30 65 ~ 30 ~ ~ ~<br />

9 CK7/CKU7 KTA7-25S-6.3A CA7-9 65 30 65 ~ ~ ~ ~ ~<br />

10 CK7/CKU7 KTA7-25S-10A CA7-12 65 30 65 ~ ~ ~ ~ ~<br />

11 CK7/CKU7 KTA7-25S-16A CA7-16 30 30 30 ~ ~ ~ ~ ~<br />

12 CK7/CKU7 KTA7-25H-4.0A CA7-23 65 30 65 ~ 30 ~ 65 30<br />

13 CK7/CKU7 KTA7-25H-16A CA7-23 30 30 65 ~ ~ ~ ~ ~<br />

14 CK7/CKU7 KTA7-25S-20A CA7-23 30 30 10 ~ ~ ~ ~ ~<br />

15 CK7/CKU7 KTA7-25S-25A CA7-23 30 30 ~ ~ ~ ~ ~ ~<br />

16 CK7/CKU7 KTA7-25H-2.5A CA7-9 65 30 65 65 30 ~ 65 ~<br />

17 CK7/CKU7 KTA7-25H-2.5A CA7-23 65 30 65 65 30 30 65 30<br />

18 CK7/CKU7 KTA7-25H-4.0A CA7-9 65 30 65 65 30 ~ ~ ~<br />

19 CK7/CKU7 KTA7-25H-4.0A CA7-23 65 30 65 65 30 30 65 30<br />

20 CK7/CKU7 KTA7-25H-6.3A CA7-9 65 30 65 65 30 ~ ~ ~<br />

21 CK7 KTA7-25H-6.3A CA7-30 65 30 65 65 30 30 65 30<br />

22 CK7/CKU7 KTA7-25H-10A CA7-12 65 30 65 65 30 ~ ~ ~<br />

23 CK7 KTA7-25H-10A CA7-30 65 30 65 65 30 30 65 30<br />

24 CK7/CKU7 KTA7-25H-16A CA7-16 65 30 65 65 30 ~ ~ ~<br />

25 CK7 KTA7-25H-16A CA7-30 65 30 65 65 30 30 65 30<br />

26 CK7/CKU7 KTA7-25H-20A CA7-23 65 30 65 65 ~ ~ ~ ~<br />

27 CK7 KTA7-25H-20A CA7-30 65 30 65 65 ~ ~ 65 ~<br />

28 CK7/CKU7 KTA7-25H-25A CA7-23 30 30 65 65 ~ ~ ~ ~<br />

29 CK7 KTA7-25H-25A CA7-30 65 30 65 65 30 30 65 30<br />

30 CK7 KTA7-45H-10A CA7-30 65 30 65 65 30 30 65 30<br />

31 CK7 KTA7-45H-16A CA7-30 65 30 65 65 30 30 65 30<br />

32 CK7 KTA7-45H-20A CA7-30 65 30 65 65 30 30 65 30<br />

33 CK7 KTA7-45H-25A CA7-30 65 30 65 65 30 30 65 30<br />

34 CK7 KTA7-45H-32A CA7-30 65 30 65 65 30 30 65 30<br />

35 CK7 KTA7-45H-45A CA7-37 65 18 65 65 ~ ~ 65 ~<br />

36 CK7 KTA7-45H-45A CA7-45 65 18 65 65 ~ ~ 65 ~<br />

480Y /<br />

277V<br />

600Y /<br />

347V<br />

F<br />

<strong>Motor</strong> <strong>Circuit</strong><br />

<strong>Controllers</strong><br />

Ecom<br />

Discount Schedule A-1<br />

F55


Wiring Diagrams<br />

Series CK7<br />

F<br />

<strong>Motor</strong> <strong>Circuit</strong><br />

<strong>Controllers</strong><br />

EcomboPlus Combination <strong>Starters</strong><br />

CK7-9...23<br />

CK7-30...43<br />

Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />

Ecom<br />

F56<br />

Discount Schedule A-1


Dimensions<br />

Series CL(U)4 and CL(U)7<br />

Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />

Ecombo Combination <strong>Starters</strong><br />

CL4 and CLU4 Ecombo <strong>Starters</strong> with <strong>KT7</strong>-25S<br />

• Dimensions are shown in millimeters (inches).<br />

• Dimensions are not intended to be used for manufacturing purposes.<br />

CL7-9…23 and CLU7-9…23 Ecombo <strong>Starters</strong> with <strong>KT7</strong>-25S<br />

• Dimensions are shown in millimeters (inches).<br />

• Dimensions are not intended to be used for manufacturing purposes.<br />

Catalog Number a a1 b b1 b2 c c1<br />

CL7-9...CL7-23 45 (1-25/32) 0 178 (7) 45 (1-25/32) ~ 83.5 (3-19/64) 70 (2-49/64)<br />

CL7-9...CL7-23 with -TE Terminal Adaptor 45 (1-25/32) 0 188 (7-13/32) 55 (2-5/32) ~ 83.5 (3-19/64) 70 (2-49/64)<br />

CLU7-9...CLU7-23 45 (1-25/32) 10 (25/64) 178 (7) 45 (1-25/32) ~ 83.5 (3-19/64) 70 (2-49/64)<br />

CLU7-9...CLU7-23 with -TE Terminal Adaptor 45 (1-25/32) 10 (25/64) 188 (7-13/32) 55 (2-5/32) ~ 83.5 (3-19/64) 70 (2-49/64)<br />

F<br />

<strong>Motor</strong> <strong>Circuit</strong><br />

<strong>Controllers</strong><br />

Ecom<br />

Discount Schedule A-1<br />

F57


Dimensions<br />

CK(U)7-9…23<br />

F<br />

<strong>Motor</strong> <strong>Circuit</strong><br />

<strong>Controllers</strong><br />

EcomboPlus Combination <strong>Starters</strong><br />

CK7-9…23 and CKU7-9…23 EcomboPlus <strong>Starters</strong><br />

• Dimensions are shown in millimeters (inches).<br />

• Dimensions are not intended to be used for manufacturing purposes.<br />

Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />

Ecom<br />

F58<br />

Discount Schedule A-1


Mounting Position and Dimensions<br />

CK7-9…23<br />

EcomboPlus Combination <strong>Starters</strong><br />

Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />

• Dimensions are shown in millimeters.<br />

• Dimensions are not intended to be used for manufacturing purposes.<br />

with "TE" Terminal Adaptor<br />

CK7-9…23<br />

F<br />

<strong>Motor</strong> <strong>Circuit</strong><br />

<strong>Controllers</strong><br />

Ecom<br />

Discount Schedule A-1<br />

F59


Dimensions<br />

CK7-30 and CK7-37<br />

F<br />

<strong>Motor</strong> <strong>Circuit</strong><br />

<strong>Controllers</strong><br />

EcomboPlus Combination <strong>Starters</strong><br />

CK7-30 and CK7-37<br />

• Dimensions are shown in millimeters.<br />

• Dimensions are not intended to be used for manufacturing purposes.<br />

A (mm) B (mm)<br />

CK7-30<br />

135 124<br />

CK7-37<br />

<strong>KT7</strong>-45H<br />

CK7-30C<br />

179 168<br />

CK7-37C<br />

C (mm)<br />

CA7-PV 154.5<br />

CZE7 173.5<br />

CV7 176.5<br />

CA7-PV 198.5<br />

Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />

Ecom<br />

F60<br />

Discount Schedule A-1


Dimensions<br />

CK7-43<br />

Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />

EcomboPlus Combination <strong>Starters</strong><br />

CK7-43<br />

• Dimensions are shown in millimeters.<br />

• Dimensions are not intended to be used for manufacturing purposes.<br />

A (mm) B (mm)<br />

CK7-43<br />

135 118.5<br />

<strong>KT7</strong>-45H<br />

CK7-43C 179 162.5<br />

C (mm)<br />

CA7-PV 157<br />

CZE7 176<br />

CV7 179<br />

CA7-PV 201<br />

F<br />

<strong>Motor</strong> <strong>Circuit</strong><br />

<strong>Controllers</strong><br />

Ecom<br />

Discount Schedule A-1<br />

F61


Mounting Position and Dimensions<br />

CK7-43<br />

EcomboPlus Combination <strong>Starters</strong><br />

F<br />

<strong>Motor</strong> <strong>Circuit</strong><br />

<strong>Controllers</strong> controller<br />

• Dimensions are shown in millimeters.<br />

• Dimensions are not intended to be used for manufacturing purposes.<br />

CK7-43<br />

Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />

Ecom<br />

F62<br />

Discount Schedule A-1


Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />

Enclosed KTA7 <strong>Controllers</strong><br />

Enclosed CX7 <strong>Starters</strong><br />

F<br />

<strong>Circuit</strong><br />

F<strong>Motor</strong> <strong>Controllers</strong> controller<br />

Encl.<br />

F63


Type E Self-Protected <strong>Manual</strong> <strong>Motor</strong> Controller<br />

Enclosed Series KTA7<br />

F<br />

<strong>Motor</strong> <strong>Circuit</strong><br />

<strong>Controllers</strong><br />

Encl.<br />

Enclosed KTA7 - IP65<br />

Max. Horsepower ➊➋➌<br />

Three Phase<br />

200V 230V 460V 575V<br />

Amp / Horsepower<br />

Rating<br />

O/L Relay<br />

Ampere<br />

Range<br />

Magnetic<br />

Response<br />

Current<br />

➊ Horsepower ratings shown in the table above are for reference. The final<br />

selection of the manual starter depends on the actual motor full load current<br />

and service factor.<br />

• For motor with service factor less than 1.15. Use motor nameplate full load<br />

current times 0.9 and choose the motor starter with the appropriate current<br />

range. Example: <strong>Motor</strong> FLC = 4.2A; S.F. = 1.0. 4.2A x 0.9 = 3.78A. Select<br />

catalog number KTA7-25S-4.0A.<br />

Non-metallic (IP65) Enclosure<br />

Catalog Number ➍<br />

Price<br />

KTA7-25S Standard Interrupting Capacity<br />

~ ~ ~ ~ 0.10…0.16 2.1 KTA7-25S-0.16A-CG 238 AY<br />

~ ~ ~ ~ 0.16…0.25 3.3 KTA7-25S-0.25A-CG 238 AY<br />

~ ~ ~ ~ 0.25…0.40 5.2 KTA7-25S-0.4A-CG 238 AY<br />

~ ~ ~ ~ 0.40…0.63 8.2 KTA7-25S-0.63A-CG 259 AY<br />

~ ~ 1/2 3/4 0.63…1.0 13 KTA7-25S-1A-CG 259 AY<br />

~ ~ 1 1 1.0…1.6 21 KTA7-25S-1.6A-CG 259 AY<br />

1/2 3/4 1-1/2 2 1.6…2.5 33 KTA7-25S-2.5A-CG 259 AY<br />

1 1 3 3 2.5…4 52 KTA7-25S-4A-CG 259 AY<br />

1-1/2 2 5 ~ 4…6.3 82 KTA7-25S-6.3A-CG 259 AY<br />

3 3 7-1/2 ~ 6.3…10 130 KTA7-25S-10A-CG 259 AY<br />

3 5 10 ~ 10…16 208 KTA7-25S-16A-CG 281 AY<br />

5 7-1/2 15 ~ 14.5…20 260 KTA7-25S-20A-CG 281 AY<br />

7-1/2 7-1/2 15 20 18…25 325 KTA7-25S-25A-CG ➏ 281 AY<br />

Modifications (Factory Assembled)<br />

Description<br />

<strong>KT7</strong> Auxiliaries & Trip Contacts - Front Mount<br />

1 NO Auxiliary<br />

1 NC Auxiliary<br />

1 NO + 1 NC Auxiliary<br />

2 NO Auxiliaries<br />

1 NO Trip + 1 NC Auxiliary<br />

1 NO Trip + 1 NO Auxiliary<br />

<strong>KT7</strong> Auxiliaries - Side Mount<br />

2 NC Auxiliaries<br />

2 NO Auxiliaries<br />

1 NO + 1 NC Auxiliary<br />

Additional <strong>KT7</strong> Trip Contacts - Side Mount<br />

1 NO Thermal-Mag + 1 NO Mag Only<br />

1 NO Thermal-Mag + 1 NC Mag Only<br />

1 NC Thermal-Mag + 1 NO Mag Only<br />

Accessories<br />

Undervoltage Release Module<br />

Shunt Release Module<br />

Select coil voltage<br />

from table at right<br />

Add Suffix to<br />

Catalog Number<br />

-A10<br />

-A01<br />

-A11<br />

-A20<br />

-T10A01<br />

-T10A10<br />

-AS02<br />

-AS20<br />

-AS11<br />

-R00<br />

-R01<br />

-R10<br />

-UA-✱<br />

-<strong>AA</strong>-✱<br />

Price<br />

Adder<br />

33<br />

33<br />

37<br />

37<br />

47<br />

47<br />

47<br />

47<br />

47<br />

56<br />

56<br />

56<br />

75<br />

75<br />

Dimension<br />

Code<br />

Coil Selection (✱)<br />

Coil Voltage Range<br />

Code 50 Hz 60 Hz<br />

24V 21V 24V<br />

28V 24V 28V<br />

120V 105V 120V<br />

127V 110V 127V<br />

230V 220...230V ~<br />

240V ~ 240...260V<br />

277V 240V 277V<br />

460V 380...400V 400...460V<br />

480V 415V 480V<br />

Includes:<br />

• Non-metallic (IP65) enclosure with integrated<br />

IP65 operator – watertight, dusttight<br />

• <strong>KT7</strong>-25S (Standard Interrupting Capacity)<br />

“Type E” Self-protected <strong>Manual</strong> Controller<br />

• Terminal Adaptor for Type E Applications<br />

(Cat.# <strong>KT7</strong>-25-TE)<br />

• Gray and black IP65 handle ➍➎<br />

Enclosure Only<br />

Description<br />

Catalog<br />

Number Price<br />

Gray/Black handle <strong>KT7</strong>-AYTG2 90<br />

Red/Yellow handle <strong>KT7</strong>-AYTJ2 90<br />

➋ Magnetic trip is fixed at 13x the maximum value of the current adjustment range.<br />

➌ KTA7 may be applied to single phase loads if 3 poles of device are wired in series.<br />

See footnote ➊ for device selection criteria.<br />

➍ A red and yellow handle may be selected instead of the standard gray and black<br />

handle. Change “CG” suffix to “CJ”. Ex: Change KTA7-25S-0.16-CG to<br />

KTA7-25S-0.16-CJ.<br />

➎ Handles are built-in to the enclosure and are not available as components.<br />

➏ KTA7-25S-25A is suitable for use as a manual motor starter only because the<br />

KTA7-25S-25A is not type E rated. Additional units on this page may be applicable<br />

as a manual motor starter only (i.e. @ 575V).<br />

➐ See F76 for dimensional information.<br />

Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />

F64<br />

Discount Schedule A-1


Type E Self Protected <strong>Manual</strong> <strong>Motor</strong> Controller<br />

Enclosed Series KTA7<br />

Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />

Enclosed KTA7 - Type 4 / 4X / 12<br />

Max. Horsepower ➊➋➌<br />

Three Phase<br />

200V 230V 460V 575V<br />

Amp / Horsepower<br />

Rating<br />

O/L Relay<br />

Ampere<br />

Range<br />

Magnetic<br />

Response<br />

Current<br />

➊ Horsepower ratings shown in the table above are for reference. The final<br />

selection of the manual starter depends on the actual motor full load current<br />

and service factor.<br />

• For motor with service factor less than 1.15. Use motor nameplate full load<br />

current times 0.9 and choose the motor starter with the appropriate current<br />

range. Example: <strong>Motor</strong> FLC = 4.2A; S.F. = 1.0. 4.2A x 0.9 = 3.78A. Select<br />

catalog number KTA7-25S-4.0A.<br />

➋ Magnetic trip is fixed at 13x the maximum value of the current adjustment range.<br />

➌ KTA7 may be applied to single phase loads if 3 poles of device are wired in series.<br />

See footnote ➊ for device selection criteria.<br />

➍ A red and yellow handle may be selected instead of the standard gray and black<br />

handle. Change “WG” suffix to “WJ”. Ex: Change KTA7-25S-0.16-VG to<br />

KTA7-25S-0.16-VJ.<br />

➎ KTA7-25S-25A is suitable for use as a manual motor starter only because the<br />

KTA7-25S-25A is not type E rated. Additional units on this page may be applicable<br />

as a manual motor starter only (i.e. @ 575V).<br />

➐ See F76 for dimensional information.<br />

Non-metallic, Type 4 / 4X / 12 Enclosure<br />

Catalog Number ➍<br />

Price<br />

KTA7-25S Standard Interrupting Capacity<br />

~ ~ ~ ~ 0.10…0.16 2.1 KTA7-25S-0.16A-VG 350 Q5<br />

~ ~ ~ ~ 0.16…0.25 3.3 KTA7-25S-0.25A-VG 350 Q5<br />

~ ~ ~ ~ 0.25…0.40 5.2 KTA7-25S-0.4A-VG 350 Q5<br />

~ ~ ~ ~ 0.40…0.63 8.2 KTA7-25S-0.63A-VG 365 Q5<br />

~ ~ 1/2 3/4 0.63…1.0 13 KTA7-25S-1A-VG 365 Q5<br />

~ ~ 1 1 1.0…1.6 21 KTA7-25S-1.6A-VG 365 Q5<br />

1/2 3/4 1-1/2 2 1.6…2.5 33 KTA7-25S-2.5A-VG 365 Q5<br />

1 1 3 3 2.5…4 52 KTA7-25S-4A-VG 365 Q5<br />

1-1/2 2 5 ~ 4…6.3 82 KTA7-25S-6.3A-VG 365 Q5<br />

3 3 7-1/2 ~ 6.3…10 130 KTA7-25S-10A-VG 365 Q5<br />

3 5 10 ~ 10…16 208 KTA7-25S-16A-VG 392 Q5<br />

5 7-1/2 15 ~ 14.5…20 260 KTA7-25S-20A-VG 392 Q5<br />

7-1/2 7-1/2 15 20 18…25 325 KTA7-25S-25A-VG ➎ 392 Q5<br />

KTA7-25H Standard Interrupting Capacity<br />

1/2 3/4 1-1/2 2 1.6…2.5 33 KTA7-25H-2.5A-VG 408 Q6<br />

1 1 3 3 2.5…4 52 KTA7-25H-4A-VG 408 Q6<br />

1-1/2 2 5 5 4…6.3 82 KTA7-25H-6.3A-VG 408 Q6<br />

3 3 7-1/2 10 6.3…10 130 KTA7-25H-10A-VG 435 Q6<br />

3 5 10 15 10…16 208 KTA7-25H-16A-VG 435 Q6<br />

5 7-1/2 15 ~ 14.5…20 260 KTA7-25H-20A-VG 435 Q6<br />

7-1/2 7-1/2 15 ~ 18…25 325 KTA7-25H-25A-VG 435 Q6<br />

KTA7-45H Standard Interrupting Capacity<br />

3 3 7-1/2 10 6.3…10 130 KTA7-45H-10A-VG R/F Q7<br />

3 5 10 15 10…16 208 KTA7-45H-16A-VG R/F Q7<br />

5 7-1/2 15 20 14.5…20 260 KTA7-45H-20A-VG R/F Q7<br />

5 7-1/2 20 25 18…25 325 KTA7-45H-25A-VG R/F Q7<br />

10 10 25 30 23…32 416 KTA7-45H-32A-VG R/F Q7<br />

15 15 30 ~ 32…45 585 KTA7-45H-45A-VG R/F Q7<br />

Dimension<br />

Code<br />

Includes:<br />

• Type 4 / 4X / 12 enclosure – watertight, dusttight,<br />

corrosion resistant<br />

• KTA7 “Type E” Self-protected <strong>Manual</strong><br />

Controller (Standard Interrupting Capacity)<br />

• Terminal Adaptor for Type E Applications<br />

(Cat.# <strong>KT7</strong>-25[45]-TE)<br />

• Gray and black Type 4/4X/12; IP66 handle<br />

(Cat.# <strong>KT7</strong>-HTN) ➍<br />

Modifications (Factory Assembled)<br />

Description<br />

<strong>KT7</strong> Auxiliaries & Trip<br />

Contacts - Front Mount<br />

1 NO Auxiliary<br />

1 NC Auxiliary<br />

1 NO + 1 NC Auxiliary<br />

2 NO Auxiliaries<br />

1 NO Trip + 1 NC Auxiliary<br />

1 NO Trip + 1 NO Auxiliary<br />

<strong>KT7</strong> Auxiliaries - Side Mount<br />

2 NC Auxiliaries<br />

2 NO Auxiliaries<br />

1 NO + 1 NC Auxiliary<br />

Additional <strong>KT7</strong> Trip Contacts,<br />

Side Mount<br />

1 NO Thermal-Mag+1 NO<br />

Mag<br />

1 NO Thermal-Mag+1 NC<br />

Mag<br />

1 NC Thermal-Mag+1 NO<br />

Mag<br />

Accessories<br />

Undervoltage Release Module<br />

Shunt Release Module<br />

Select coil voltage from table below<br />

Coil Selection (✱)<br />

Coil Voltage Range<br />

Code 50 Hz 60 Hz<br />

24V 21V 24V<br />

28V 24V 28V<br />

120V 105V 120V<br />

127V 110V 127V<br />

230V 220...230V ~<br />

240V ~ 240...260V<br />

277V 240V 277V<br />

460V 380...400V 400...460V<br />

480V 415V 480V<br />

Add Suffix<br />

to Cat.<br />

Number<br />

-A10<br />

-A01<br />

-A11<br />

-A20<br />

-T10A01<br />

-T10A10<br />

-AS02<br />

-AS20<br />

-AS11<br />

-R00<br />

-R01<br />

-R10<br />

-UA-✱<br />

-<strong>AA</strong>-✱<br />

Price<br />

Adder<br />

33<br />

33<br />

37<br />

37<br />

47<br />

47<br />

47<br />

47<br />

47<br />

56<br />

56<br />

56<br />

75<br />

75<br />

F<br />

<strong>Motor</strong> <strong>Circuit</strong><br />

<strong>Controllers</strong><br />

Encl.<br />

Discount Schedule A-1<br />

F65


Type E Self-Protected <strong>Manual</strong> <strong>Motor</strong> Controller<br />

Enclosed Series KTA7<br />

F<br />

<strong>Motor</strong> <strong>Circuit</strong><br />

<strong>Controllers</strong><br />

Encl.<br />

Enclosed KTA7 - Type 12<br />

Max. Horsepower ➊➋➌<br />

Three Phase<br />

200V 230V 460V 575V<br />

Amp / Horsepower<br />

Rating<br />

O/L Relay<br />

Ampere<br />

Range<br />

Magnetic<br />

Response<br />

Current<br />

Painted Steel, Type 12 Enclosure<br />

Catalog Number ➍<br />

Price<br />

KTA7-25S Standard Interrupting Capacity<br />

~ ~ ~ ~ 0.10…0.16 2.1 KTA7-25S-0.16A-DG 375 L<br />

~ ~ ~ ~ 0.16…0.25 3.3 KTA7-25S-0.25A-DG 375 L<br />

~ ~ ~ ~ 0.25…0.40 5.2 KTA7-25S-0.4A-DG 375 L<br />

~ ~ ~ ~ 0.40…0.63 8.2 KTA7-25S-0.63A-DG 395 L<br />

~ ~ 1/2 3/4 0.63…1.0 13 KTA7-25S-1A-DG 395 L<br />

~ ~ 1 1 1.0…1.6 21 KTA7-25S-1.6A-DG 395 L<br />

1/2 3/4 1-1/2 2 1.6…2.5 33 KTA7-25S-2.5A-DG 395 L<br />

1 1 3 3 2.5…4 52 KTA7-25S-4A-DG 395 L<br />

1-1/2 2 5 ~ 4…6.3 82 KTA7-25S-6.3A-DG 395 L<br />

3 3 7-1/2 ~ 6.3…10 130 KTA7-25S-10A-DG 395 L<br />

3 5 10 ~ 10…16 208 KTA7-25S-16A-DG 395 L<br />

5 7-1/2 15 ~ 14.5…20 260 KTA7-25S-20A-DG 417 L<br />

7-1/2 7-1/2 15 20 18…25 325 KTA7-25S-25A-DG ➎ 417 L<br />

KTA7-25H Standard Interrupting Capacity<br />

1/2 3/4 1-1/2 2 1.6…2.5 33 KTA7-25H-2.5A-DG 433 L<br />

1 1 3 3 2.5…4 52 KTA7-25H-4A-DG 433 L<br />

1-1/2 2 5 5 4…6.3 82 KTA7-25H-6.3A-DG 433 L<br />

3 3 7-1/2 10 6.3…10 130 KTA7-25H-10A-DG 460 L<br />

3 5 10 15 10…16 208 KTA7-25H-16A-DG 460 L<br />

5 7-1/2 15 ~ 14.5…20 260 KTA7-25H-20A-DG 460 L<br />

7-1/2 7-1/2 15 ~ 18…25 325 KTA7-25H-25A-DG 460 L<br />

➊ Horsepower ratings shown in the table above are for reference. The final<br />

selection of the manual starter depends on the actual motor full load current<br />

and service factor.<br />

• For motor with service factor less than 1.15. Use motor nameplate full load<br />

current times 0.9 and choose the motor starter with the appropriate current<br />

range. Example: <strong>Motor</strong> FLC = 4.2A; S.F. = 1.0. 4.2A x 0.9 = 3.78A. Select<br />

catalog number KTA7-25S-4.0A.<br />

➋ Magnetic trip is fixed at 13x the maximum value of the current adjustment range.<br />

➌ KTA7 may be applied to single phase loads if 3 poles of device are wired in series.<br />

See footnote ➊ for device selection criteria.<br />

➍ A red and yellow handle may be selected instead of the standard gray and black<br />

handle. Change “DG” suffix to “DJ”. Ex: Change KTA7-25S-0.16-DG to<br />

KTA7-25S-0.16-DJ.<br />

➎ KTA7-25S-25A is suitable for use as a manual motor starter only because the<br />

KTA7-25S-25A is not type E rated. Additional units on this page may be applicable<br />

as a manual motor starter only (i.e. @ 575V).<br />

➏ See F76 for dimensional information.<br />

Dimension<br />

Code<br />

Includes:<br />

• Type 12 enclosure – dusttight<br />

• KTA7 “Type E” Self-protected <strong>Manual</strong><br />

Controller (Standard Interrupting Capacity)<br />

• Terminal Adaptor for Type E Applications<br />

(Cat.# <strong>KT7</strong>-25-TE)<br />

• Gray and black Type 4/4X/12; IP66 handle<br />

(Cat.# <strong>KT7</strong>-HTN) ➍<br />

Modifications (Factory Assembled)<br />

Description<br />

<strong>KT7</strong> Auxiliaries & Trip<br />

Contacts - Front Mount<br />

1 NO Auxiliary<br />

1 NC Auxiliary<br />

1 NO + 1 NC Auxiliary<br />

2 NO Auxiliaries<br />

1 NO Trip + 1 NC Auxiliary<br />

1 NO Trip + 1 NO Auxiliary<br />

<strong>KT7</strong> Auxiliaries - Side Mount<br />

2 NC Auxiliaries<br />

2 NO Auxiliaries<br />

1 NO + 1 NC Auxiliary<br />

Additional <strong>KT7</strong> Trip Contacts,<br />

Side Mount<br />

1 NO Thermal-Mag+1 NO<br />

Mag<br />

1 NO Thermal-Mag+1 NC<br />

Mag<br />

1 NC Thermal-Mag+1 NO<br />

Mag<br />

Accessories<br />

Undervoltage Release Module<br />

Shunt Release Module<br />

Select coil voltage from table below<br />

Coil Selection (✱)<br />

Coil Voltage Range<br />

Code 50 Hz 60 Hz<br />

24V 21V 24V<br />

28V 24V 28V<br />

120V 105V 120V<br />

127V 110V 127V<br />

230V 220...230V ~<br />

240V ~ 240...260V<br />

277V 240V 277V<br />

460V 380...400V 400...460V<br />

480V 415V 480V<br />

Add Suffix<br />

to Cat.<br />

Number<br />

-A10<br />

-A01<br />

-A11<br />

-A20<br />

-T10A01<br />

-T10A10<br />

-AS02<br />

-AS20<br />

-AS11<br />

-R00<br />

-R01<br />

-R10<br />

-UA-✱<br />

-<strong>AA</strong>-✱<br />

Price<br />

Adder<br />

33<br />

33<br />

37<br />

37<br />

47<br />

47<br />

47<br />

47<br />

47<br />

56<br />

56<br />

56<br />

75<br />

75<br />

Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />

F66<br />

Discount Schedule A-1


Type E Self-Protected <strong>Manual</strong> <strong>Motor</strong> Controller<br />

Enclosed Series KTA7<br />

Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />

Enclosed KTA7 - Type 4 / 12<br />

Max. Horsepower ➊➋➌<br />

Three Phase<br />

200V 230V 460V 575V<br />

Amp / Horsepower<br />

Rating<br />

O/L Relay<br />

Ampere<br />

Range<br />

Magnetic<br />

Response<br />

Current<br />

➊ Horsepower ratings shown in the table above are for reference. The final<br />

selection of the manual starter depends on the actual motor full load current<br />

and service factor.<br />

• For motor with service factor less than 1.15. Use motor nameplate full load<br />

current times 0.9 and choose the motor starter with the appropriate current<br />

range. Example: <strong>Motor</strong> FLC = 4.2A; S.F. = 1.0. 4.2A x 0.9 = 3.78A. Select<br />

catalog number KTA7-25S-4.0A.<br />

➋ Magnetic trip is fixed at 13x the maximum value of the current adjustment range.<br />

➌ KTA7 may be applied to single phase loads if 3 poles of device are wired in series.<br />

See footnote ➊ for device selection criteria.<br />

➍ A red and yellow handle may be selected instead of the standard gray and black<br />

handle. Change “WG” suffix to “WJ”. Ex: Change KTA7-25S-0.16-WG to<br />

KTA7-25S-0.16-WJ.<br />

➎ KTA7-25S-25A is suitable for use as a manual motor starter only because the<br />

KTA7-25S-25A is not type E rated. Additional units on this page may be applicable<br />

as a manual motor starter only (i.e. @ 575V).<br />

➏ See F76 for dimensional information.<br />

Painted Steel, Type 4 / 12 Enclosure<br />

Catalog Number ➍<br />

KTA7-25S Standard Interrupting Capacity<br />

~ ~ ~ ~ 0.10…0.16 2.1 KTA7-25S-0.16A-WG 417 W6<br />

~ ~ ~ ~ 0.16…0.25 3.3 KTA7-25S-0.25A-WG 417 W6<br />

~ ~ ~ ~ 0.25…0.40 5.2 KTA7-25S-0.4A-WG 417 W6<br />

~ ~ ~ ~ 0.40…0.63 8.2 KTA7-25S-0.63A-WG 437 W6<br />

~ ~ 1/2 3/4 0.63…1.0 13 KTA7-25S-1A-WG 437 W6<br />

~ ~ 1 1 1.0…1.6 21 KTA7-25S-1.6A-WG 437 W6<br />

1/2 3/4 1-1/2 2 1.6…2.5 33 KTA7-25S-2.5A-WG 437 W6<br />

1 1 3 3 2.5…4 52 KTA7-25S-4A-WG 437 W6<br />

1-1/2 2 5 ~ 4…6.3 82 KTA7-25S-6.3A-WG 437 W6<br />

3 3 7-1/2 ~ 6.3…10 130 KTA7-25S-10A-WG 437 W6<br />

3 5 10 ~ 10…16 208 KTA7-25S-16A-WG 459 W6<br />

5 7-1/2 15 ~ 14.5…20 260 KTA7-25S-20A-WG 459 W6<br />

7-1/2 7-1/2 15 20 18…25 325 KTA7-25S-25A-WG ➎ 459 W6<br />

KTA7-25H Standard Interrupting Capacity<br />

1/2 3/4 1-1/2 2 1.6…2.5 33 KTA7-25H-2.5A-WG 475 W6<br />

1 1 3 3 2.5…4 52 KTA7-25H-4A-WG 475 W6<br />

1-1/2 2 5 5 4…6.3 82 KTA7-25H-6.3A-WG 475 W6<br />

3 3 7-1/2 10 6.3…10 130 KTA7-25H-10A-WG 502 W6<br />

3 5 10 15 10…16 208 KTA7-25H-16A-WG 502 W6<br />

5 7-1/2 15 ~ 14.5…20 260 KTA7-25H-20A-WG 502 W6<br />

7-1/2 7-1/2 15 ~ 18…25 325 KTA7-25H-25A-WG 502 W6<br />

KTA7-45H Standard Interrupting Capacity<br />

3 3 7-1/2 10 6.3…10 130 KTA7-45H-10A-WG 671 R/F<br />

3 5 10 15 10…16 208 KTA7-45H-16A-WG 671 R/F<br />

5 7-1/2 15 20 14.5…20 260 KTA7-45H-20A-WG 671 R/F<br />

5 7-1/2 20 25 18…25 325 KTA7-45H-25A-WG 671 R/F<br />

10 10 25 30 23…32 416 KTA7-45H-32A-WG 709 R/F<br />

15 15 30 ~ 32…45 585 KTA7-45H-45A-WG 709 R/F<br />

Price<br />

Dimension<br />

Code<br />

Includes:<br />

• Type 4 / 12 enclosure – watertight, dusttight<br />

• KTA7 “Type E” Self-protected <strong>Manual</strong><br />

Controller (Standard Interrupting Capacity)<br />

• Terminal Adaptor for Type E Applications<br />

(Cat.# <strong>KT7</strong>-25[45]-TE)<br />

• Gray and black Type 4/4X/12; IP66 handle<br />

(Cat.# <strong>KT7</strong>-HTN) ➍<br />

Modifications (Factory Assembled)<br />

Description<br />

<strong>KT7</strong> Auxiliaries & Trip<br />

Contacts - Front Mount<br />

1 NO Auxiliary<br />

1 NC Auxiliary<br />

1 NO + 1 NC Auxiliary<br />

2 NO Auxiliaries<br />

1 NO Trip + 1 NC Auxiliary<br />

1 NO Trip + 1 NO Auxiliary<br />

<strong>KT7</strong> Auxiliaries - Side Mount<br />

2 NC Auxiliaries<br />

2 NO Auxiliaries<br />

1 NO + 1 NC Auxiliary<br />

Additional <strong>KT7</strong> Trip Contacts,<br />

Side Mount<br />

1 NO Thermal-Mag+1 NO<br />

Mag<br />

1 NO Thermal-Mag+1 NC<br />

Mag<br />

1 NC Thermal-Mag+1 NO<br />

Mag<br />

Accessories<br />

Undervoltage Release Module<br />

Shunt Release Module<br />

Select coil voltage from table below<br />

Coil Selection (✱)<br />

Coil Voltage Range<br />

Code 50 Hz 60 Hz<br />

24V 21V 24V<br />

28V 24V 28V<br />

120V 105V 120V<br />

127V 110V 127V<br />

230V 220...230V ~<br />

240V ~ 240...260V<br />

277V 240V 277V<br />

460V 380...400V 400...460V<br />

480V 415V 480V<br />

Add Suffix<br />

to Cat.<br />

Number<br />

-A10<br />

-A01<br />

-A11<br />

-A20<br />

-T10A01<br />

-T10A10<br />

-AS02<br />

-AS20<br />

-AS11<br />

-R00<br />

-R01<br />

-R10<br />

-UA-✱<br />

-<strong>AA</strong>-✱<br />

Price<br />

Adder<br />

33<br />

33<br />

37<br />

37<br />

47<br />

47<br />

47<br />

47<br />

47<br />

56<br />

56<br />

56<br />

75<br />

75<br />

F<br />

<strong>Motor</strong> <strong>Circuit</strong><br />

<strong>Controllers</strong><br />

Encl.<br />

Discount Schedule A-1<br />

F67


Non-Reversing Combination Controller, AC<br />

Enclosed Series CX7<br />

F<br />

<strong>Motor</strong> <strong>Circuit</strong><br />

<strong>Controllers</strong><br />

Encl.<br />

Enclosed Non-Reversing Combination Controller, AC Operation - Type 4 / 12<br />

Max. Horsepower ➊➋➌<br />

Three Phase<br />

200V 230V 460V 575V<br />

Amp / Horsepower<br />

Rating<br />

O/L Relay<br />

Ampere<br />

Range<br />

Magnetic<br />

Response<br />

Current<br />

Painted Steel, Type 4 / 12 Enclosure<br />

Catalog Number ➍<br />

KTA7-25S Standard Interrupting Capacity<br />

~ ~ ~ ~ 0.10…0.16 2.1 CX7-9-10-✱-AS0.16A-A10-WG 548 W6<br />

~ ~ ~ ~ 0.16…0.25 3.3 CX7-9-10-✱-AS0.25A-A10-WG 548 W6<br />

~ ~ ~ ~ 0.25…0.40 5.2 CX7-9-10-✱-AS0.4A-A10-WG 569 W6<br />

~ ~ ~ ~ 0.40…0.63 8.2 CX7-9-10-✱-AS0.63A-A10-WG 569 W6<br />

~ ~ 1/2 3/4 0.63…1.0 13 CX7-9-10-✱-AS1A-A10-WG 569 W6<br />

~ ~ 1 1 1.0…1.6 21 CX7-9-10-✱-AS1.6A-A10-WG 569 W6<br />

1/2 3/4 1-1/2 2 1.6…2.5 33 CX7-9-10-✱-AS2.5A-A10-WG 569 W6<br />

1 1 3 3 2.5…4 52 CX7-9-10-✱-AS4A-A10-WG 569 W6<br />

1-1/2 2 5 ~ 4…6.3 82 CX7-9-10-✱-AS6.3A-A10-WG 569 W6<br />

3 3 7-1/2 ~ 6.3…10 130 CX7-12-10-✱-AS10A-A10-WG 590 W6<br />

3 5 10 ~ 10…16 208 CX7-16-10-✱-AS16A-A10-WG 623 W6<br />

5 7-1/2 15 ~ 14.5…20 260 CX7-23-10-✱-AS20A-A10-WG 636 W6<br />

KTA7-25H Standard Interrupting Capacity<br />

1/2 3/4 1-1/2 2 1.6…2.5 33 CX7-9-10-✱-AH2.5A-A10-WG 606 W6<br />

1 1 3 3 2.5…4 52 CX7-9-10-✱-AH4A-A10-WG 606 W6<br />

1-1/2 2 5 5 4…6.3 82 CX7-9-10-✱-AH6.3A-A10-WG 606 W6<br />

3 3 7-1/2 10 6.3…10 130 CX7-12-10-✱-AH10A-A10-WG 654 W6<br />

3 5 10 15 10…16 208 CX7-16-10-✱-AH16A-A10-WG 666 W6<br />

5 7-1/2 15 ~ 14.5…20 260 CX7-23-10-✱-AH20A-A10-WG 679 W6<br />

5 7-1/2 15 ~ 18…25 325 CX7-23-10-✱-AH25A-A10-WG 679 W6<br />

KTA7-45H Standard Interrupting Capacity<br />

3 3 7-1/2 10 6.3…10 130 CX7-30-10-✱-AH10A-A10-WG 831 W7<br />

3 5 10 15 10…16 208 CX7-30-10-✱-AH16A-A10-WG 831 W7<br />

5 7-1/2 15 15 14.5…20 260 CX7-30-10-✱-AH20A-A10-WG 831 W7<br />

5 7-1/2 15 15 18…25 325 CX7-30-10-✱-AH25A-A10-WG 831 W7<br />

7-1/2 10 20 25 23…32 416 CX7-30-10-✱-AH32A-A10-WG 850 W7<br />

10 10 25 30 32…45 585 CX7-37-10-✱-AH45A-A10-WG 894 W7<br />

10 15 30 ~ 32…45 585 CX7-43-10-✱-AH45A-A10-WG 908 W7<br />

Ordering Instructions<br />

Specify Catalog Number<br />

Replace (✱) with Coil Code<br />

Select modifications if required<br />

See Coil Code tables on<br />

this page for codes<br />

Price<br />

Dimension<br />

Code<br />

Includes:<br />

• Type 12 / 4 enclosure - watertight, dustight<br />

• KTA7 “Type E” Self-protected <strong>Motor</strong><br />

Controller with 1 NO front mount Auxiliary<br />

Contact (Cat #: <strong>KT7</strong>-PE1-10)<br />

• Terminal Adaptor for Type E Applications<br />

(Cat.# <strong>KT7</strong>-25[45]-TE)<br />

• CA7 contactor (for remote operation), AC coil<br />

• Power wiring<br />

• Gray and black Type 4/4X/12; IP66 handle<br />

(Cat.# <strong>KT7</strong>-HTN) ➍<br />

• Pilot device shown is factory installed option<br />

See page 72 for factory installed modifications<br />

Coil Codes (✱) ➎<br />

A.C.<br />

Coil Code<br />

Voltage Range<br />

50 Hz 60 Hz<br />

24Z 24V 24V<br />

120 110V 120V<br />

208 ~ 208V<br />

220W ~ 208V-240V<br />

240 220V 240V<br />

277 240V 277V<br />

380 380...400V 440V<br />

480 440V 480V<br />

600 550V 600V<br />

➊ Horsepower ratings shown in the table above are<br />

for reference. The final selection of the manual<br />

starter depends on the actual motor full load current<br />

and service factor.<br />

• For motor with service factor less than 1.15. Use<br />

motor nameplate full load current times 0.9 and<br />

choose the motor starter with the appropriate<br />

current range. Example: <strong>Motor</strong> FLC = 4.2A; S.F. =<br />

1.0. 4.2A x 0.9 = 3.78A. Select catalog number<br />

KTA7-25S-4.0A.<br />

➋ Magnetic trip is fixed at 13x the maximum value of the current adjustment range.<br />

➌ CX7 may be applied to single phase loads. See footnote 1 for device selection criteria.<br />

To order single phase unit, change “CX7” in catalog number to “CBX7”. Three<br />

pole series connection will be provided. Ex: Change CX7-9-10-✱-0.16A-A10-WG<br />

to CBX7-9-10-✱-0.16A-A10-WJ.<br />

➍ A red and yellow handle may be selected instead of the standard gray and black<br />

handle. Change “WG” suffix to “WJ”. Ex: Change CX7-9-10-✱-0.16A-A10-WG to<br />

CX7-9-10-✱-0.16A-A10-WJ.<br />

➎ Other voltages available, see Section A in this catalog. Non-standard coil voltages<br />

not listed here must be ordered and installed separately as renewal parts.<br />

➏ See F76 for dimensional information.<br />

Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />

F68<br />

Discount Schedule A-1


Reversing Combination Controller, AC<br />

Enclosed Series CXU7<br />

Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />

Enclosed Reversing Combination Controller, AC Operation - Type 4 / 12<br />

Max. Horsepower ➊➋➌<br />

Three Phase<br />

Amp / Horsepower<br />

Rating<br />

200V 230V 460V 575V<br />

O/L Relay<br />

Ampere<br />

Range<br />

Magnetic<br />

Response<br />

Current<br />

Painted Steel, Type 4 / 12 Enclosure<br />

Catalog Number ➍<br />

KTA7-25S Standard Interrupting Capacity<br />

~ ~ ~ ~ 0.10…0.16 2.1 CXU7-9-22-✱-AS0.16A-A10-WG 600 W6<br />

~ ~ ~ ~ 0.16…0.25 3.3 CXU7-9-22-✱-AS0.25A-A10-WG 600 W6<br />

~ ~ ~ ~ 0.25…0.40 5.2 CXU7-9-22-✱-AS0.4A-A10-WG 600 W6<br />

~ ~ ~ ~ 0.40…0.63 8.2 CXU7-9-22-✱-AS0.63A-A10-WG 620 W6<br />

~ ~ 1/2 3/4 0.63…1.0 13 CXU7-9-22-✱-AS1A-A10-WG 620 W6<br />

~ ~ 1 1 1.0…1.6 21 CXU7-9-22-✱-AS1.6A-A10-WG 620 W6<br />

1/2 3/4 1-1/2 2 1.6…2.5 33 CXU7-9-22-✱-AS2.5A-A10-WG 620 W6<br />

1 1 3 3 2.5…4 52 CXU7-9-22-✱-AS4A-A10-WG 620 W6<br />

1-1/2 2 5 ~ 4…6.3 82 CXU7-9-22-✱-AS6.3A-A10-WG 620 W6<br />

3 3 7-1/2 ~ 6.3…10 130 CXU7-12-22-✱-AS10A-A10-WG 646 W6<br />

3 5 10 ~ 10…16 208 CXU7-16-22-✱-AS16A-A10-WG 683 W6<br />

5 7-1/2 15 ~ 14.5…20 260 CXU7-23-22-✱-AS20A-A10-WG 698 W6<br />

KTA7-25H Standard Interrupting Capacity<br />

1/2 3/4 1-1/2 2 1.6…2.5 33 CXU7-9-22-✱-AH2.5A-A10-WG 657 W6<br />

1 1 3 3 2.5…4 52 CXU7-9-22-✱-AH4A-A10-WG 657 W6<br />

1-1/2 2 5 5 4…6.3 82 CXU7-9-22-✱-AH6.3A-A10-WG 657 W6<br />

3 3 7-1/2 10 6.3…10 130 CXU7-12-22-✱-AH10A-A10-WG 711 W6<br />

3 5 10 15 10…16 208 CXU7-16-22-✱-AH16A-A10-WG 726 W6<br />

5 7-1/2 15 ~ 14.5…20 260 CXU7-23-22-✱-AH20A-A10-WG 741 W6<br />

7-1/2 7-1/2 15 ~ 18…25 325 CXU7-23-22-✱-AH25A-A10-WG 741 W6<br />

KTA7-45H Standard Interrupting Capacity<br />

3 3 7-1/2 10 6.3…10 130 CXU7-30-22-✱-AH10A-A10-WG 869 W7<br />

3 5 10 15 10…16 208 CXU7-30-22-✱-AH16A-A10-WG 869 W7<br />

5 7-1/2 15 20 14.5…20 260 CXU7-30-22-✱-AH20A-A10-WG 869 W7<br />

5 7-1/2 20 25 18…25 325 CXU7-30-22-✱-AH25A-A10-WG 869 W7<br />

7-1/2 10 20 25 23…32 416 CXU7-30-22-✱-AH32A-A10-WG 900 W7<br />

10 10 25 30 32…45 585 CXU7-37-22-✱-AH45A-A10-WG 943 W7<br />

10 15 30 ~ 32…45 585 CXU7-43-22-✱-AH45A-A10-WG 979 W7<br />

Ordering Instructions<br />

Specify Catalog Number<br />

Replace (✱) with Coil Code<br />

Select modifications if required<br />

See Coil Code tables on<br />

this page for codes<br />

Price<br />

Dimension<br />

Code<br />

Includes:<br />

• Type 12 / 4 enclosure - watertight, dustight<br />

• <strong>KT7</strong> “Type E” <strong>Motor</strong> Controller with 1 NO<br />

front mount Auxiliary Contact<br />

(Cat #: <strong>KT7</strong>-PE1-10)<br />

• Terminal Adaptor for Type E Applications<br />

(Cat.# <strong>KT7</strong>-25[45]-TE)<br />

• CA7 contactors (for remote operation),<br />

AC coil<br />

• Power wiring<br />

• Gray and black Type 4/4X/12; IP66 handle<br />

(Cat.# <strong>KT7</strong>-HTN) ➍<br />

• Control power transformer, pilot device,<br />

terminals and other equipment shown are<br />

factory installed options<br />

See page 72 for factory installed modifications<br />

Coil Codes (✱) ➎<br />

A.C.<br />

Coil Code<br />

Voltage Range<br />

50 Hz 60 Hz<br />

24Z 24V 24V<br />

120 110V 120V<br />

208 ~ 208V<br />

220W ~ 208V-240V<br />

240 220V 240V<br />

277 240V 277V<br />

380 380...400V 440V<br />

480 440V 480V<br />

600 550V 600V<br />

➊ Horsepower ratings shown in the table above are<br />

for reference. The final selection of the manual<br />

starter depends on the actual motor full load current<br />

and service factor.<br />

• For motor with service factor less than 1.15. Use<br />

motor nameplate full load current times 0.9 and<br />

choose the motor starter with the appropriate<br />

current range. Example: <strong>Motor</strong> FLC = 4.2A; S.F. =<br />

1.0. 4.2A x 0.9 = 3.78A. Select catalog number<br />

KTA7-25S-4.0A.<br />

➋ Magnetic trip is fixed at 13x the maximum value of the current adjustment range.<br />

➌ CXU7 may be applied to single phase loads. Contact factory for these applications.<br />

➍ A red and yellow handle may be selected instead of the standard gray and black<br />

handle. Change “WG” suffix to “WJ”. Ex: Change CXU7-9-10-✱-0.16A-A10-WG to<br />

CXU7-9-10-✱-0.16A-A10-WJ.<br />

➎ Other voltages available, see Section A in this catalog. Non-standard coil voltages<br />

not listed here must be ordered and installed separately as renewal parts.<br />

➏ See F76 for dimensional information.<br />

F<br />

<strong>Motor</strong> <strong>Circuit</strong><br />

<strong>Controllers</strong><br />

Encl.<br />

Discount Schedule A-1<br />

F69


Non-Reversing Combination Controller, DC<br />

Enclosed Series CX7<br />

F<br />

<strong>Motor</strong> <strong>Circuit</strong><br />

<strong>Controllers</strong><br />

Encl.<br />

Enclosed Non-Reversing Combination Controller, True DC Coil - Type 4 / 12<br />

Max. Horsepower ➊➋➌<br />

Three Phase<br />

Amp / Horsepower<br />

Rating<br />

200V 230V 460V 575V<br />

O/L Relay<br />

Ampere<br />

Range<br />

Magnetic<br />

Response<br />

Current<br />

Painted Steel, Type 4 / 12 Enclosure<br />

Catalog Number ➍<br />

KTA7-25S Standard Interrupting Capacity<br />

~ ~ ~ ~ 0.10…0.16 2.1 CX7-9C-10-✱-AS0.16A-A10-WG 685 W6<br />

~ ~ ~ ~ 0.16…0.25 3.3 CX7-9C-10-✱-AS0.25A-A10-WG 685 W6<br />

~ ~ ~ ~ 0.25…0.40 5.2 CX7-9C-10-✱-AS0.4A-A10-WG 685 W6<br />

~ ~ ~ ~ 0.40…0.63 8.2 CX7-9C-10-✱-AS0.63A-A10-WG 705 W6<br />

~ ~ 1/2 3/4 0.63…1.0 13 CX7-9C-10-✱-AS1A-A10-WG 705 W6<br />

~ ~ 1 1 1.0…1.6 21 CX7-9C-10-✱-AS1.6A-A10-WG 705 W6<br />

1/2 3/4 1-1/2 2 1.6…2.5 33 CX7-9C-10-✱-AS2.5A-A10-WG 705 W6<br />

1 1 3 3 2.5…4 52 CX7-9C-10-✱-AS4A-A10-WG 705 W6<br />

1-1/2 2 5 ~ 4…6.3 82 CX7-9C-10-✱-AS6.3A-A10-WG 705 W6<br />

3 3 7-1/2 ~ 6.3…10 130 CX7-12C-10-✱-AS10A-A10-WG 746 W6<br />

3 5 10 ~ 10…16 208 CX7-16C-10-✱-AS16A-A10-WG 792 W6<br />

5 7-1/2 15 ~ 14.5…20 260 CX7-23C-10-✱-AS20A-A10-WG 818 W6<br />

KTA7-25H Standard Interrupting Capacity<br />

1/2 3/4 1-1/2 2 1.6…2.5 33 CX7-9C-10-✱-AH2.5A-A10-WG 742 W6<br />

1 1 3 3 2.5…4 52 CX7-9C-10-✱-AH4A-A10-WG 742 W6<br />

1-1/2 2 5 5 4…6.3 82 CX7-9C-10-✱-AH6.3A-A10-WG 742 W6<br />

3 3 7-1/2 10 6.3…10 130 CX7-12C-10-✱-AH10A-A10-WG 811 W6<br />

3 5 10 15 10…16 208 CX7-16C-10-✱-AH16A-A10-WG 835 W6<br />

5 7-1/2 15 ~ 14.5…20 260 CX7-23C-10-✱-AH20A-A10-WG 861 W6<br />

7-1/2 7-1/2 15 ~ 18…25 325 CX7-23C-10-✱-AH25A-A10-WG 861 W6<br />

KTA7-45H Standard Interrupting Capacity<br />

3 3 7-1/2 10 6.3…10 130 CX7-30C-10-✱-AH10A-A10-WG 1039 W7<br />

3 5 10 15 10…16 208 CX7-30C-10-✱-AH16A-A10-WG 1039 W7<br />

5 7-1/2 15 20 14.5…20 260 CX7-30C-10-✱-AH20A-A10-WG 1039 W7<br />

5 7-1/2 20 25 18…25 325 CX7-30C-10-✱-AH25A-A10-WG 1039 W7<br />

7-1/2 10 20 25 23…32 416 CX7-30C-10-✱-AH32A-A10-WG 1000 W7<br />

10 10 25 30 32…45 585 CX7-37C-10-✱-AH45A-A10-WG 1131 W7<br />

10 15 30 ~ 32…45 585 CX7-43C-10-✱-AH45A-A10-WG 1172 W7<br />

Ordering Instructions<br />

Specify Catalog Number<br />

Replace (✱) with Coil Code<br />

Select modifications if required<br />

See Coil Code tables on<br />

this page for codes<br />

Price<br />

Dimension<br />

Code<br />

Includes:<br />

• Type 12 / 4 enclosure - watertight, dustight<br />

• <strong>KT7</strong> “Type E” <strong>Motor</strong> Controller with 1 NO<br />

front mount Auxiliary Contact<br />

(Cat #: <strong>KT7</strong>-PE1-10)<br />

• Terminal Adaptor for Type E Applications<br />

(Cat.# <strong>KT7</strong>-25[45]-TE)<br />

• CA7 contactor (for remote operation),<br />

true DC coil<br />

• Power wiring<br />

• Gray and black Type 4/4X/12; IP66 handle<br />

(Cat.# <strong>KT7</strong>-HTN) ➍<br />

• Pilot device shown is factory installed option<br />

See page 72 for factory installed modifications<br />

Coil Codes (✱) ➎<br />

D.C.<br />

Coil Code<br />

12D<br />

24D<br />

48D<br />

110D<br />

220D<br />

Voltage<br />

12V<br />

24V<br />

48V<br />

110V<br />

220V<br />

➊ Horsepower ratings shown in the table above are<br />

for reference. The final selection of the manual<br />

starter depends on the actual motor full load current<br />

and service factor.<br />

• For motor with service factor less than 1.15. Use<br />

motor nameplate full load current times 0.9 and<br />

choose the motor starter with the appropriate<br />

current range. Example: <strong>Motor</strong> FLC = 4.2A; S.F. =<br />

1.0. 4.2A x 0.9 = 3.78A. Select catalog number<br />

KTA7-25S-4.0A.<br />

➋ Magnetic trip is fixed at 13x the maximum value of the current adjustment range.<br />

➌ CX7 may be applied to single phase loads. See footnote 1 for device selection criteria.<br />

To order single phase unit, change “CX7” in catalog number to “CBX7”. Three<br />

pole series connection will be provided. Ex: Change CX7-9-10-✱-0.16A-A10-WG<br />

to CBX7-9-10-✱-0.16A-A10-WJ.<br />

➍ A red and yellow handle may be selected instead of the standard gray and black<br />

handle. Change “WG” suffix to “WJ”. Ex: Change CX7-9-10-✱-0.16A-A10-WG to<br />

CX7-9-10-✱-0.16A-A10-WJ.<br />

➎ Other voltages available, see Section A in this catalog. Non-standard coil voltages<br />

not listed here must be ordered and installed separately as renewal parts.<br />

➏ See F76 for dimensional information.<br />

Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />

F70<br />

Discount Schedule A-1


Reversing Combination Controller, DC<br />

Enclosed Series CXU7<br />

Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />

Enclosed Reversing Combination Controller, True DC Coil - Type 4 / 12<br />

Max. Horsepower ➊➋➌<br />

Three Phase<br />

Amp / Horsepower<br />

Rating<br />

200V 230V 460V 575V<br />

O/L Relay<br />

Ampere<br />

Range<br />

Magnetic<br />

Response<br />

Current<br />

Painted Steel, Type 4 / 12 Enclosure<br />

Catalog Number ➍<br />

KTA7-25S Standard Interrupting Capacity<br />

~ ~ ~ ~ 0.10…0.16 2.1 CXU7-9C-22-✱-AS0.16A-A10-WG 752 W6<br />

~ ~ ~ ~ 0.16…0.25 3.3 CXU7-9C-22-✱-AS0.25A-A10-WG 752 W6<br />

~ ~ ~ ~ 0.25…0.40 5.2 CXU7-9C-22-✱-AS0.4A-A10-WG 752 W6<br />

~ ~ ~ ~ 0.40…0.63 8.2 CXU7-9C-22-✱-AS0.63A-A10-WG 772 W6<br />

~ ~ 1/2 3/4 0.63…1.0 13 CXU7-9C-22-✱-AS1A-A10-WG 772 W6<br />

~ ~ 1 1 1.0…1.6 21 CXU7-9C-22-✱-AS1.6A-A10-WG 772 W6<br />

1/2 3/4 1-1/2 2 1.6…2.5 33 CXU7-9C-22-✱-AS2.5A-A10-WG 772 W6<br />

1 1 3 3 2.5…4 52 CXU7-9C-22-✱-AS4A-A10-WG 772 W6<br />

1-1/2 2 5 ~ 4…6.3 82 CXU7-9C-22-✱-AS6.3A-A10-WG 772 W6<br />

3 3 7-1/2 ~ 6.3…10 130 CXU7-12C-22-✱-AS10A-A10-WG 826 W6<br />

3 5 10 ~ 10…16 208 CXU7-16C-22-✱-AS16A-A10-WG 878 W6<br />

5 7-1/2 15 ~ 14.5…20 260 CXU7-23C-22-✱-AS20A-A10-WG 910 W6<br />

KTA7-25H Standard Interrupting Capacity<br />

1/2 3/4 1-1/2 2 1.6…2.5 33 CXU7-9C-22-✱-AH2.5A-A10-WG 810 W6<br />

1 1 3 3 2.5…4 52 CXU7-9C-22-✱-AH4A-A10-WG 810 W6<br />

1-1/2 2 5 5 4…6.3 82 CXU7-9C-22-✱-AH6.3A-A10-WG 810 W6<br />

3 3 7-1/2 10 6.3…10 130 CXU7-12C-22-✱-AH10A-A10-WG 891 W6<br />

3 5 10 15 10…16 208 CXU7-16C-22-✱-AH16A-A10-WG 921 W6<br />

5 7-1/2 15 ~ 14.5…20 260 CXU7-23C-22-✱-AH20A-A10-WG 953 W6<br />

7-1/2 7-1/2 15 ~ 18…25 325 CXU7-23C-22-✱-AH25A-A10-WG 953 W6<br />

KTA7-45H Standard Interrupting Capacity<br />

3 3 7-1/2 10 6.3…10 130 CXU7-30C-22-✱-AH10A-A10-WG 1118 W7<br />

3 5 10 15 10…16 208 CXU7-30C-22-✱-AH16A-A10-WG 1118 W7<br />

5 7-1/2 15 20 14.5…20 260 CXU7-30C-22-✱-AH20A-A10-WG 1118 W7<br />

5 7-1/2 20 25 18…25 325 CXU7-30C-22-✱-AH25A-A10-WG 1118 W7<br />

7-1/2 10 20 25 23…32 416 CXU7-30C-22-✱-AH32A-A10-WG 1200 W7<br />

10 10 25 30 32…45 585 CXU7-37C-22-✱-AH45A-A10-WG 1275 W7<br />

10 15 30 ~ 32…45 585 CXU7-43C-22-✱-AH45A-A10-WG 1319 W7<br />

Ordering Instructions<br />

Specify Catalog Number<br />

Replace (✱) with Coil Code<br />

Select modifications if required<br />

See Coil Code tables on<br />

this page for codes<br />

Price<br />

Dimension<br />

Code<br />

Includes:<br />

• Type 12 / 4 enclosure - watertight, dustight<br />

• <strong>KT7</strong> “Type E” <strong>Motor</strong> Controller with 1 NO<br />

front mount Auxiliary Contact<br />

(Cat #: <strong>KT7</strong>-PE1-10)<br />

• Terminal Adaptor for Type E Applications<br />

(Cat.# <strong>KT7</strong>-25[45]-TE)<br />

• CA7 contactors (for remote operation),<br />

true DC coil<br />

• Power wiring<br />

• Gray and black Type 4/4X/12; IP66 handle<br />

(Cat.# <strong>KT7</strong>-HTN) ➍<br />

• Control power transformer, pilot device,<br />

terminals and other equipment shown are<br />

factory installed options<br />

See page 72 for factory installed modifications<br />

Coil Codes (✱) ➎<br />

D.C.<br />

Coil Code<br />

12D<br />

24D<br />

48D<br />

110D<br />

220D<br />

Voltage<br />

12V<br />

24V<br />

48V<br />

110V<br />

220V<br />

➊ Horsepower ratings shown in the table above are<br />

for reference. The final selection of the manual<br />

starter depends on the actual motor full load current<br />

and service factor.<br />

• For motor with service factor less than 1.15. Use<br />

motor nameplate full load current times 0.9 and<br />

choose the motor starter with the appropriate<br />

current range. Example: <strong>Motor</strong> FLC = 4.2A; S.F. =<br />

1.0. 4.2A x 0.9 = 3.78A. Select catalog number<br />

KTA7-25S-4.0A.<br />

➋ Magnetic trip is fixed at 13x the maximum value of the current adjustment range.<br />

➌ CXU7 may be applied to single phase loads. Contact factory for these applications.<br />

➍ A red and yellow handle may be selected instead of the standard gray and black<br />

handle. Change “WG” suffix to “WJ”. Ex: Change CXU7-9-10-✱-0.16A-A10-WG to<br />

CXU7-9-10-✱-0.16A-A10-WJ.<br />

➎ Other voltages available, see Section A in this catalog. Non-standard coil voltages<br />

not listed here must be ordered and installed separately as renewal parts.<br />

➏ See F76 for dimensional information.<br />

F<br />

<strong>Motor</strong> <strong>Circuit</strong><br />

<strong>Controllers</strong><br />

Encl.<br />

Discount Schedule A-1<br />

F71


Enclosed Combination Controller<br />

Modifications<br />

F<br />

<strong>Motor</strong> <strong>Circuit</strong><br />

<strong>Controllers</strong><br />

Non-Reversing and Reversing Combination Controller Modifications (Factory Assembled)<br />

Description<br />

Pilot Devices ➊<br />

Add Suffix to<br />

Catalog Number<br />

Price<br />

Adder<br />

START-STOP multi-function pushbutton -3U 115<br />

ON-OFF multi-function pushbutton -4U 115<br />

FOR-STOP-REV multi-function pushbutton -3U 210<br />

UP-STOP-DOWN multi-function pushbutton -4U 210<br />

OPEN-STOP-CLOSE multi-function pushbutton -5U 210<br />

HAND-AUTO selector switch -5 115<br />

OFF-ON selector switch -6 115<br />

HAND-OFF-AUTO selector switch -7 115<br />

FOR-OFF-REV selector switch -6 115<br />

UP-OFF-DOWN selector switch -7 115<br />

OPEN-OFF-CLOSE selector switch -8 115<br />

Pilot light only -1 80<br />

Pilot lights only (2) -2 155<br />

Pilot light w/ START-STOP multi-function pushbutton -13U 195<br />

Pilot light w/ ON-OFF multi-function pushbutton -14U 195<br />

Pilot light w/ HAND-AUTO selector switch -15 195<br />

Pilot light w/ OFF-ON selector switch -16 195<br />

Pilot light w/ HAND-OFF-AUTO selector switch -17 195<br />

Control Power Transformer (with fused secondary)<br />

Primary volts Secondary volts<br />

50 watt<br />

Standard<br />

Capacity<br />

208 120 -XA 140<br />

240 120 -XB 140<br />

480 120 -XC 140<br />

575 120 -XD 140<br />

380 110 -XG 140<br />

240 24 -XE 140<br />

480 24 -XF 140<br />

<strong>KT7</strong> Auxiliaries & Trip Contacts - Front Mount<br />

1 NO Auxiliary -A10 33<br />

1 NC Auxiliary -A01 33<br />

1 NO + 1 NC Auxiliary -A11 37<br />

2 NO Auxiliaries -A20 37<br />

1 NO Trip + 1 NC Auxiliary -T10A01 47<br />

1 NO Trip + 1 NO Auxiliary -T10A10 47<br />

<strong>KT7</strong> Auxiliaries - Side Mount<br />

2 NC Auxiliaries -AS02 47<br />

2 NO Auxiliaries -AS20 47<br />

1 NO + 1 NC Auxiliary -AS11 47<br />

Additional <strong>KT7</strong> Trip Contacts - Side Mount<br />

1 NO Thermal-Mag + 1 NO Mag Only -R00 56<br />

1 NO Thermal-Mag + 1 NC Mag Only -R01 56<br />

1 NC Thermal-Mag + 1 NO Mag Only -R10 56<br />

<strong>KT7</strong> Accessories<br />

Undervoltage Release Module<br />

Select coil voltage<br />

from table at right -UA-✱ 75<br />

Description<br />

Add Suffix to<br />

Catalog Number<br />

Price<br />

Adder<br />

Shunt Release Module -<strong>AA</strong>-✱ 75<br />

CA7 Auxiliary Contacts<br />

1 NO Auxiliary -S10 27<br />

1 NC Auxiliary -S01 27<br />

1 NO + 1 NC Auxiliary -S11 34<br />

2 NO Auxiliaries -S20 34<br />

2 NC Auxiliaries -S02 34<br />

1 NO + 2 NC Auxiliary -S12 38<br />

2 NO + 1 NC Auxiliary -S21 38<br />

3 NO Auxiliaries -S30 38<br />

3 NC Auxiliaries -S03 38<br />

1 NO + 3 NC Auxiliary -S13 45<br />

3 NO + 1 NC Auxiliary -S31 45<br />

2 NO + 2 NC Auxiliary -S22 45<br />

4 NO Auxiliaries -S40 45<br />

4 NC Auxiliaries -S04 45<br />

Alternate Aux. Contact Arrangement (CA7 only)<br />

1 NC in lieu of standard 1 NO -SX10 10<br />

2 NC in lieu of standard 2 NO (on CXU7 only) -SX2 10<br />

CA7 Contactor Accessories<br />

Electronic Interface -JE 56<br />

Surge Suppressor RC -C 32<br />

Surge Suppressor Varistor -V 24<br />

Surge Suppressor Diode -D 31<br />

Unwired Terminal Blocks Specify quantity (▼) -▼TB 13<br />

Coil Selection (✱)<br />

Coil Voltage Range<br />

Code 50 Hz 60 Hz<br />

24V 21V 24V<br />

28V 24V 28V<br />

120V 105V 120V<br />

127V 110V 127V<br />

230V 220...230V ~<br />

240V ~ 240...260V<br />

277V 240V 277V<br />

460V 380...400V 400...460V<br />

480V 415V 480V<br />

Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />

Encl.<br />

➊ Multi-function pushbuttons with protective boots are supplied as standard (all<br />

suffix’s ending in “U”). See Section H in this catalog for description.<br />

F72<br />

Discount Schedule A-1


<strong>Manual</strong> <strong>Motor</strong> Controller<br />

Explosion-Proof Series KTA7<br />

Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />

KTA7 Explosion Proof <strong>Motor</strong> <strong>Controllers</strong> - Type 7 / 9<br />

Max. Horsepower ➊➋➌<br />

Three Phase<br />

200V 230V 460V 575V<br />

Amp / Horsepower<br />

Rating<br />

O/L Relay<br />

Ampere<br />

Range<br />

Modifications (Factory Assembled)<br />

Magnetic<br />

Response<br />

Current<br />

➊ Horsepower ratings shown in the table above are for reference. The final<br />

selection of the manual starter depends on the actual motor full load current<br />

and service factor.<br />

• For motor with service factor less than 1.15. Use motor nameplate full load<br />

current times 0.9 and choose the motor starter with the appropriate current<br />

range. Example: <strong>Motor</strong> FLC = 4.2A; S.F. = 1.0. 4.2A x 0.9 = 3.78A. Select<br />

catalog number KTA7-25S-4.0A.<br />

➋ Magnetic trip is fixed at 13x the maximum value of the current adjustment range.<br />

➌ KTA7 may be applied to single phase loads if 3 poles of device are wired in series.<br />

See footnote ➊ for device selection criteria.<br />

➍ KTA7-25S-25A is suitable for use as a manual motor starter only because the<br />

KTA7-25S-25A is not type E rated. Additional units on this page may be applicable<br />

as a manual motor starter only (i.e. @ 575V).<br />

➎ See F76 for dimensional information.<br />

Explosion Proof - Type 7 / 9 Enclosure<br />

Catalog Number<br />

Price<br />

KTA7-25S Standard Interrupting Capacity<br />

~ ~ ~ ~ 0.10…0.16 2.1 KTA7-25S-0.16A-EX 508 EX<br />

~ ~ ~ ~ 0.16…0.25 3.3 KTA7-25S-0.25A-EX 508 EX<br />

~ ~ ~ ~ 0.25…0.40 5.2 KTA7-25S-0.4A-EX 508 EX<br />

~ ~ ~ ~ 0.40…0.63 8.2 KTA7-25S-0.63A-EX 529 EX<br />

~ ~ 1/2 3/4 0.63…1.0 13 KTA7-25S-1A-EX 529 EX<br />

~ ~ 1 1 1.0…1.6 21 KTA7-25S-1.6A-EX 529 EX<br />

1/2 3/4 1-1/2 2 1.6…2.5 33 KTA7-25S-2.5A-EX 529 EX<br />

1 1 3 3 2.5…4 52 KTA7-25S-4A-EX 529 EX<br />

1-1/2 2 5 ~ 4…6.3 82 KTA7-25S-6.3A-EX 529 EX<br />

3 3 7-1/2 ~ 6.3…10 130 KTA7-25S-10A-EX 529 EX<br />

3 5 10 ~ 10…16 208 KTA7-25S-16A-EX 551 EX<br />

5 7-1/2 15 ~ 14.5…20 260 KTA7-25S-20A-EX 551 EX<br />

7-1/2 7-1/2 15 20 18…25 325 KTA7-25S-25-EX ➍ 551 EX<br />

Description<br />

<strong>KT7</strong> Auxiliaries & Trip Contacts - Front Mount<br />

1 NO Auxiliary<br />

1 NC Auxiliary<br />

1 NO + 1 NC Auxiliary<br />

2 NO Auxiliaries<br />

1 NO Trip + 1 NC Auxiliary<br />

1 NO Trip + 1 NO Auxiliary<br />

Add Suffix to<br />

Catalog Number<br />

-A10<br />

-A01<br />

-A11<br />

-A20<br />

-T10A01<br />

-T10A10<br />

Price<br />

Adder<br />

33<br />

33<br />

37<br />

37<br />

47<br />

47<br />

Enclosure Modifications<br />

Breather/Drain -BD 65<br />

Dimension<br />

Code<br />

Includes:<br />

• Class I, Group C & D –<br />

Class II, Group E, F & G enclosure<br />

• <strong>KT7</strong> “Type E” Self-protected <strong>Manual</strong> <strong>Motor</strong><br />

Controller (Standard interrupting capacity)<br />

• Terminal Adaptor for Type E Applications<br />

(Cat.# <strong>KT7</strong>-25-TE)<br />

F<br />

<strong>Motor</strong> <strong>Circuit</strong><br />

<strong>Controllers</strong><br />

Encl.<br />

Discount Schedule A-1<br />

F73


Self-protected <strong>Manual</strong> <strong>Motor</strong> Controller<br />

Explosion-Proof Series KTA7<br />

F<br />

<strong>Motor</strong> <strong>Circuit</strong><br />

<strong>Controllers</strong><br />

Encl.<br />

KTA7 Explosion Proof <strong>Motor</strong> <strong>Controllers</strong> – Type 7 / 9 with Type 4 Gaskets<br />

Max. Horsepower ➊➋➌<br />

Three Phase<br />

Amp / Horsepower<br />

Rating<br />

200V 230V 460V 575V<br />

O/L Relay<br />

Ampere<br />

Range<br />

Magnetic<br />

Response<br />

Current<br />

➊ Horsepower ratings shown in the table above are for reference. The final<br />

selection of the manual starter depends on the actual motor full load current<br />

and service factor.<br />

• For motor with service factor less than 1.15. Use motor nameplate full load<br />

current times 0.9 and choose the motor starter with the appropriate current<br />

range. Example: <strong>Motor</strong> FLC = 4.2A; S.F. = 1.0. 4.2A x 0.9 = 3.78A. Select<br />

catalog number KTA7-25S-4.0A.<br />

➋ Magnetic trip is fixed at 13x the maximum value of the current adjustment range.<br />

➌ KTA7 may be applied to single phase loads if 3 poles of device are wired in series.<br />

See footnote ➊ for device selection criteria.<br />

➍ See F76 for dimensional information.<br />

Explosion Proof - Type 7 / 9 Enclosure<br />

(with Type 4 Gaskets)<br />

Catalog Number<br />

KTA7-25S Standard Interrupting Capacity<br />

~ ~ ~ ~ 0.10…0.16 2.1 KTA7-25S-0.16A-EY 733 EY<br />

~ ~ ~ ~ 0.16…0.25 3.3 KTA7-25S-0.25A-EY 733 EY<br />

~ ~ ~ ~ 0.25…0.40 5.2 KTA7-25S-0.4A-EY 733 EY<br />

~ ~ ~ ~ 0.40…0.63 8.2 KTA7-25S-0.63A-EY 754 EY<br />

~ ~ 1/2 3/4 0.63…1.0 13 KTA7-25S-1A-EY 754 EY<br />

~ ~ 1 1 1.0…1.6 21 KTA7-25S-1.6A-EY 754 EY<br />

1/2 3/4 1-1/2 2 1.6…2.5 33 KTA7-25S-2.5A-EY 754 EY<br />

1 1 3 3 2.5…4 52 KTA7-25S-4A-EY 754 EY<br />

1-1/2 2 5 ~ 4…6.3 82 KTA7-25S-6.3A-EY 754 EY<br />

3 3 7-1/2 ~ 6.3…10 130 KTA7-25S-10A-EY 754 EY<br />

3 5 10 ~ 10…16 208 KTA7-25S-16A-EY 776 EY<br />

5 7-1/2 15 ~ 14.5…20 260 KTA7-25S-20A-EY 776 EY<br />

KTA7-25H Standard Interrupting Capacity<br />

1/2 3/4 1-1/2 2 1.6…2.5 33 KTA7-25H-2.5A-EY 793 EY<br />

1 1 3 3 2.5…4 52 KTA7-25H-4A-EY 793 EY<br />

1-1/2 2 5 5 4…6.3 82 KTA7-25H-6.3A-EY 793 EY<br />

3 3 7-1/2 10 6.3…10 130 KTA7-25H-10A-EY 820 EY<br />

3 5 10 15 10…16 208 KTA7-25H-16A-EY 820 EY<br />

5 7-1/2 15 ~ 14.5…20 260 KTA7-25H-20A-EY 820 EY<br />

7-1/2 7-1/2 15 ~ 18…25 325 KTA7-25H-25A-EY 820 EY<br />

KTA7-45H Standard Interrupting Capacity<br />

3 3 7-1/2 10 6.3…10 130 KTA7-45H-10A-EZ 1159 EZ<br />

3 5 10 15 10…16 208 KTA7-45H-16A-EZ 1159 EZ<br />

5 7-1/2 15 20 14.5…20 260 KTA7-45H-20A-EZ 1159 EZ<br />

5 7-1/2 20 25 18…25 325 KTA7-45H-25A-EZ 1159 EZ<br />

10 10 25 30 23…32 416 KTA7-45H-32A-EZ 1197 EZ<br />

15 15 30 ~ 32…45 585 KTA7-45H-45A-EZ 1197 EZ<br />

Price<br />

Dimension<br />

Code<br />

Includes:<br />

• Class I, Group B, C & D –<br />

Class II, Group E, F & G enclosure<br />

• <strong>KT7</strong> “Type E” Self-protected <strong>Manual</strong> <strong>Motor</strong><br />

Controller (Standard interrupting capacity)<br />

• Terminal Adaptor for Type E Applications<br />

(Cat.# <strong>KT7</strong>-25[45]-TE)<br />

Modifications (Factory Assembled)<br />

Description<br />

<strong>KT7</strong> Auxiliaries & Trip<br />

Contacts - Front Mount<br />

1 NO Auxiliary<br />

1 NC Auxiliary<br />

1 NO + 1 NC Auxiliary<br />

2 NO Auxiliaries<br />

1 NO Trip + 1 NC Auxiliary<br />

1 NO Trip + 1 NO Auxiliary<br />

<strong>KT7</strong> Auxiliaries - Side Mount<br />

2 NC Auxiliaries<br />

2 NO Auxiliaries<br />

1 NO + 1 NC Auxiliary<br />

Coil Selection (✱)<br />

Coil Voltage Range<br />

Code 50 Hz 60 Hz<br />

24V 21V 24V<br />

28V 24V 28V<br />

120V 105V 120V<br />

127V 110V 127V<br />

230V 220...230V ~<br />

240V ~ 240...260V<br />

277V 240V 277V<br />

460V 380...400V 400...460V<br />

480V 415V 480V<br />

Add Suffix to<br />

Cat. Number<br />

-A10<br />

-A01<br />

-A11<br />

-A20<br />

-T10A01<br />

-T10A10<br />

-AS02<br />

-AS20<br />

-AS11<br />

Additional <strong>KT7</strong> Trip Contacts,<br />

Side Mount<br />

1 NO Thermal-Mag+1 NO Mag -R00<br />

1 NO Thermal-Mag+1 NC Mag -R01<br />

1 NC Thermal-Mag+1 NO Mag -R10<br />

Accessories<br />

Undervoltage Release Module<br />

Shunt Release Module<br />

Select coil voltage from table below<br />

-UA-✱<br />

-<strong>AA</strong>-✱<br />

Price<br />

Adder<br />

33<br />

33<br />

37<br />

37<br />

47<br />

47<br />

47<br />

47<br />

47<br />

56<br />

56<br />

56<br />

75<br />

75<br />

Enclosure Modifications<br />

Breather/Drain -BD 65<br />

Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />

F74<br />

Discount Schedule A-1


Combination Controller<br />

Explosion-Proof Series CX7<br />

Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />

CX7 Explosion Proof Combination <strong>Controllers</strong> - Type 7 / 9<br />

Max. Horsepower ➊➋➌<br />

Three Phase<br />

Amp / Horsepower<br />

Rating<br />

200V 230V 460V 575V<br />

O/L Relay<br />

Ampere<br />

Range<br />

Magnetic<br />

Response<br />

Current<br />

➊ Horsepower ratings shown in the table above are for reference. The final<br />

selection of the manual starter depends on the actual motor full load current<br />

and service factor.<br />

• For motor with service factor less than 1.15. Use motor nameplate full load<br />

current times 0.9 and choose the motor starter with the appropriate current<br />

range. Example: <strong>Motor</strong> FLC = 4.2A; S.F. = 1.0. 4.2A x 0.9 = 3.78A. Select<br />

catalog number KTA7-25S-4.0A.<br />

➋ Magnetic trip is fixed at 13x the maximum value of the current adjustment range.<br />

➌ CX7 may be applied to single phase loads. See footnote 1 for device selection criteria.<br />

To order single phase unit, change “CX7” in catalog number to “CBX7”. Three<br />

pole series connection will be provided. Ex: Change CX7-9-10-✱-0.16A-A10-WG<br />

to CBX7-9-10-✱-0.16A-A10-WJ.<br />

➍ See F76 for dimensional information.<br />

Explosion Proof - Type 7 / 9 Enclosure<br />

(with Type 4 Gaskets)<br />

Catalog Number<br />

KTA7-25S Standard Interrupting Capacity<br />

~ ~ ~ ~ 0.10…0.16 2.1 CX7-9-10-✱-AS0.16A-A10-EZ 1071 EZ<br />

~ ~ ~ ~ 0.16…0.25 3.3 CX7-9-10-✱-AS0.25A-A10-EZ 1071 EZ<br />

~ ~ ~ ~ 0.25…0.40 5.2 CX7-9-10-✱-AS0.4A-A10-EZ 1071 EZ<br />

~ ~ ~ ~ 0.40…0.63 8.2 CX7-9-10-✱-AS0.63A-A10-EZ 1092 EZ<br />

~ ~ 1/2 3/4 0.63…1.0 13 CX7-9-10-✱-AS1A-A10-EZ 1092 EZ<br />

~ ~ 1 1 1.0…1.6 21 CX7-9-10-✱-AS1.6A-A10-EZ 1092 EZ<br />

1/2 3/4 1-1/2 2 1.6…2.5 33 CX7-9-10-✱-AS2.5A-A10-EZ 1092 EZ<br />

1 1 3 3 2.5…4 52 CX7-9-10-✱-AS4A-A10-EZ 1092 EZ<br />

1-1/2 2 5 ~ 4…6.3 82 CX7-9-10-✱-AS6.3A-A10-EZ 1092 EZ<br />

3 3 7-1/2 ~ 6.3…10 130 CX7-12-10-✱-AS10A-A10-EZ 1112 EZ<br />

3 5 10 ~ 10…16 208 CX7-16-10-✱-AS16A-A10-EZ 1146 EZ<br />

5 7-1/2 15 ~ 14.5…20 260 CX7-23-10-✱-AS20A-A10-EZ 1158 EZ<br />

KTA7-25H Standard Interrupting Capacity<br />

1/2 3/4 1-1/2 2 1.6…2.5 33 CX7-9-10-✱-AH2.5A-A10-EZ 1131 EZ<br />

1 1 3 3 2.5…4 52 CX7-9-10-✱-AH4A-A10-EZ 1131 EZ<br />

1-1/2 2 5 5 4…6.3 82 CX7-9-10-✱-AH6.3A-A10-EZ 1131 EZ<br />

3 3 7-1/2 10 6.3…10 130 CX7-12-10-✱-AH10A-A10-EZ 1178 EZ<br />

3 5 10 15 10…16 208 CX7-16-10-✱-AH16A-A10-EZ 1190 EZ<br />

5 7-1/2 15 ~ 14.5…20 260 CX7-23-10-✱-AH20A-A10-EZ 1202 EZ<br />

7-1/2 7-1/2 15 ~ 18…25 325 CX7-23-10-✱-AH25A-A10-EZ 1202 EZ<br />

KTA7-45H Standard Interrupting Capacity<br />

3 3 7-1/2 10 6.3…10 130 CX7-30-10-✱-AH10A-A10-EZ 1318 EZ<br />

3 5 10 15 10…16 208 CX7-30-10-✱-AH16A-A10-EZ 1318 EZ<br />

5 7-1/2 15 20 14.5…20 260 CX7-30-10-✱-AH20A-A10-EZ 1318 EZ<br />

5 7-1/2 20 25 18…25 325 CX7-30-10-✱-AH25A-A10-EZ 1318 EZ<br />

7-1/2 10 20 25 23…32 416 CX7-30-10-✱-AH32A-A10-EZ 1340 EZ<br />

10 10 25 30 32…45 585 CX7-37-10-✱-AH45A-A10-EZ 1381 EZ<br />

15 15 30 ~ 32…45 585 CX7-43-10-✱-AH45A-A10-EZ 1393 EZ<br />

Price<br />

Dimension<br />

Code<br />

Includes:<br />

• Class I, Group B, C & D –<br />

Class II, Group E, F & G enclosure<br />

• <strong>KT7</strong> “Type E” Self-protected <strong>Manual</strong> <strong>Motor</strong><br />

Controller with 1 NO front mount auxiliary<br />

contact (Cat.# <strong>KT7</strong>-PE1-10)<br />

• Terminal Adaptor for Type E Applications<br />

(Cat.# <strong>KT7</strong>-25[45]-TE)<br />

• CA7 contactor (for remote operation), AC coil<br />

• Power wiring<br />

Coil Codes (✱) ➍<br />

A.C.<br />

Coil Code<br />

Voltage Range<br />

50 Hz 60 Hz<br />

24Z 24V 24V<br />

120 110V 120V<br />

208 ~ 208V<br />

220W ~ 208V-240V<br />

240 220V 240V<br />

277 240V 277V<br />

380 380...400V 440V<br />

480 440V 480V<br />

600 550V 600V<br />

Modifications (Factory Assembled)<br />

Description<br />

<strong>KT7</strong> Auxiliaries & Trip<br />

Contacts - Front Mount<br />

1 NO Auxiliary<br />

1 NC Auxiliary<br />

1 NO + 1 NC Auxiliary<br />

2 NO Auxiliaries<br />

1 NO Trip + 1 NC Auxiliary<br />

1 NO Trip + 1 NO Auxiliary<br />

Description<br />

CA7 Contactor Auxiliaries<br />

1 NC Auxiliary<br />

1 NO Auxiliary<br />

CA7 Contactor Accessories<br />

Electronic Interface<br />

Surge Suppressor RC<br />

Surge Suppressor Varistor<br />

Surge Suppressor Diode<br />

Enclosure Modifications<br />

Dual START/STOP pushbutton<br />

ON/OFF selector switch<br />

H-O-A<br />

Breather/Drain<br />

Change “A10”<br />

in Cat. # to...<br />

-A10<br />

-A01<br />

-A11<br />

-A20<br />

-T10A01<br />

-T10A10<br />

Add Suffix to<br />

Cat. Number<br />

-S01<br />

-S10<br />

-JE<br />

-R<br />

-V<br />

-D<br />

Price<br />

Adder<br />

33<br />

33<br />

37<br />

37<br />

47<br />

47<br />

Price<br />

Adder<br />

➍ Other voltages available, see Section A in this catalog. Non-standard coil voltages<br />

not listed here must be ordered and installed separately as renewal parts.<br />

Ordering Instructions<br />

Specify Catalog Number<br />

Replace (✱) with Coil Code<br />

Select modifications if required<br />

-3<br />

-6<br />

-7<br />

-BD<br />

27<br />

27<br />

56<br />

32<br />

24<br />

31<br />

115<br />

115<br />

115<br />

65<br />

See Coil Code tables on<br />

this page for codes<br />

F<br />

<strong>Motor</strong> <strong>Circuit</strong><br />

<strong>Controllers</strong><br />

Encl.<br />

Discount Schedule A-1<br />

F75


Dimensions<br />

Enclosed Series <strong>KT7</strong> <strong>Motor</strong> Controller<br />

F<br />

<strong>Motor</strong> <strong>Circuit</strong><br />

<strong>Controllers</strong><br />

• Dimensions are shown in decimal inches.<br />

• Dimensions are not intended to be used for manufacturing purposes.<br />

Enclosures<br />

Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />

Encl.<br />

F76<br />

Discount Schedule A-1


Wiring Diagrams<br />

<strong>KT7</strong> <strong>Motor</strong> <strong>Circuit</strong> Controller<br />

Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />

Single, Two and Three Phase Connection Diagram<br />

F<br />

<strong>Motor</strong> <strong>Circuit</strong><br />

<strong>Controllers</strong><br />

Encl.<br />

Discount Schedule A-1<br />

F77


Technical Information<br />

IP Ratings Definitions<br />

IP Ratings Definitions<br />

F<br />

<strong>Motor</strong> <strong>Circuit</strong><br />

<strong>Controllers</strong><br />

Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />

Encl.<br />

F78<br />

Discount Schedule A-1


Technical Information<br />

Ratings Definitions<br />

Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />

NEMA / UL Type Definitions<br />

NEMA / UL Type<br />

Indoor Use Outdoor Use Indoor or Outdoor Use<br />

For a degree of protection against: 1 12 13 3R 3 4 4X 6P 6<br />

Incidental contact with enclosed equipment • • • • • • • • •<br />

Falling dirt • • • • • • • • •<br />

Rust • • • • • • • • •<br />

Circulating dust, lint, fibers and flyings • • • • • • •<br />

Windblown dust • • • • •<br />

Falling liquids and light splashing • • • • • • •<br />

Rain (limited water allowed inside) • • • • • •<br />

Rain (no water allowed inside) • • • • •<br />

Snow and sleet • • • • • •<br />

Hosedown and splashing water • • • •<br />

Occasional prolonged submersion • •<br />

Oil or coolant spraying or splashing<br />

•<br />

Corrosive agents • •<br />

Occasional temporary submersion • •<br />

F<br />

<strong>Motor</strong> <strong>Circuit</strong><br />

<strong>Controllers</strong><br />

Encl.<br />

Discount Schedule A-1<br />

F79


<strong>Motor</strong> Current Rating Chart<br />

F<br />

<strong>Motor</strong> <strong>Circuit</strong><br />

<strong>Controllers</strong><br />

Encl.<br />

60 Hz AC Induction <strong>Motor</strong><br />

Horsepower<br />

Single Phase<br />

Three Phase<br />

115 Volt 230 Volt 200 Volt 230 Volt 380-415 Volt 460 Volt 575 Volt<br />

1/6 4.4 2.2 ~ ~ ~ ~<br />

1/4 5.8 2.9 ~ ~ ~ ~<br />

1/3 7.2 3.6 ~ ~ ~ ~<br />

1/2 9.8 4.9 2.5 2.2 1.3 1.1 0.9<br />

3/4 13.8 6.9 3.7 3.2 1.8 1.6 1.3<br />

1 16.0 8.0 4.8 4.2 2.3 2.1 1.7<br />

1 1/2 20.0 10.0 6.9 6.0 3.3 3.0 2.4<br />

2 24.0 12.0 7.8 6.8 4.3 3.4 2.7<br />

3 34.0 17.0 11.0 9.6 6.1 4.8 3.9<br />

5 56.0 28.0 17.5 15.2 9.7 7.6 6.1<br />

7 1/2 80.0 40.0 25.0 22.0 14.0 11.0 9.0<br />

10 100 50.0 32.0 28.0 18.0 14.0 11.0<br />

15 135 68.0 48.0 42.0 27.0 21.0 17.0<br />

20 ~ 88.0 62.0 54.0 34.0 27.0 22.0<br />

25 ~ 110 78.0 68.0 43.0 34.0 27.0<br />

30 ~ 136 92.0 80.0 51.0 40.0 32.0<br />

40 ~ 176 120 104 66.0 52.0 41.0<br />

50 ~ 216 150 130 83.0 65.0 52.0<br />

60 ~ ~ 177 154 103 77.0 62.0<br />

75 ~ ~ 221 192 128 96.0 77.0<br />

100 ~ ~ 285 248 165 124 99.0<br />

125 ~ ~ 359 312 125 156 125<br />

150 ~ ~ 414 360 150 180 144<br />

175 ~ ~ 475 413 275 207 168<br />

200 ~ ~ 552 480 320 240 192<br />

250 ~ ~ 692 602 403 302 242<br />

300 ~ ~ ~ ~ 482 361 289<br />

350 ~ ~ ~ ~ 560 414 336<br />

400 ~ ~ ~ ~ 636 477 382<br />

450 ~ ~ ~ ~ 711 515 412<br />

500 ~ ~ ~ ~ 786 590 472<br />

The information in this chart was derived from Table 430-148 &<br />

430-150 of the NEC and Table 50.1 of UL standard 508A. The voltages<br />

listed are rated motor voltages. The currents listed shall be permitted<br />

for system voltage ranges of 110-120, 220-240, 380-415, 440-480<br />

and 550-600 volts.<br />

The full-load current values are for motors running at usual speeds and<br />

motors with normal torque characteristics. <strong>Motor</strong>s built for especially<br />

low speeds or high torques may have higher full-load currents, and<br />

multi-speed motors will have full-load currents varying with speed. In<br />

these cases, the nameplate current ratings shall be used.<br />

Caution: The actual motor amps may be higher or lower than the<br />

average values listed above. For more reliable motor protection,<br />

use the actual motor current as listed on the motor nameplate.<br />

Use this table as a guide only<br />

Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />

F80<br />

Discount Schedule A-1


Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />

Methods of Applying<br />

<strong>KT7</strong> <strong>Motor</strong> <strong>Circuit</strong> <strong>Controllers</strong><br />

This information is provided to aid in proper system design and utilization<br />

of the new <strong>KT7</strong> <strong>Motor</strong> <strong>Circuit</strong> Controller in North American applications. Be<br />

sure to consider all applicable local and national codes for your particular<br />

installation.<br />

F<br />

<strong>Motor</strong> <strong>Circuit</strong><br />

<strong>Controllers</strong><br />

Apps.<br />

F81


Application Notes<br />

Series <strong>KT7</strong> <strong>Motor</strong> <strong>Circuit</strong> <strong>Controllers</strong><br />

Methods of Applying <strong>KT7</strong> <strong>Motor</strong> <strong>Circuit</strong> <strong>Controllers</strong><br />

F<br />

<strong>Motor</strong> <strong>Circuit</strong><br />

<strong>Controllers</strong><br />

The <strong>KT7</strong> <strong>Motor</strong> <strong>Circuit</strong> Controller provides Class 10 overload protection,<br />

as well as, current limiting short-circuit protection for individual<br />

motor loads. <strong>KT7</strong>s are also approved for use as circuit breakers (per<br />

IEC 947-6-2) for applications outside of North America. In the United<br />

States and Canada, however, they are UL/CSA listed as <strong>Manual</strong> <strong>Starters</strong><br />

with optional approvals for <strong>Motor</strong> Disconnecting and Group <strong>Motor</strong><br />

applications.<br />

<strong>KT7</strong> <strong>Motor</strong> <strong>Circuit</strong> <strong>Controllers</strong> are also UL/CSA listed as <strong>Manual</strong> Combination<br />

(Type E) <strong>Starters</strong> eliminating the requirement for additional<br />

short-circuit protection in many applications. This reduces both panel<br />

space and cost in multi-motor installations and eliminates the restrictive<br />

NEC/CEC rules that pertained to <strong>Manual</strong> <strong>Starters</strong> used in Group <strong>Motor</strong><br />

applications.<br />

The following information is provided to aid in proper system design and<br />

utilization of the capabilities of the new <strong>KT7</strong> <strong>Motor</strong> <strong>Circuit</strong> Controller<br />

in North American applications. Please be sure to consider all applicable<br />

local and national codes for your particular installation.<br />

<strong>Circuit</strong> Breaker Applications – IEC<br />

<strong>KT7</strong> <strong>Motor</strong> <strong>Circuit</strong> <strong>Controllers</strong> are current limiting IEC circuit breakers<br />

(lEC 947-6-2) that also provide Class 10 motor overload protection. Additionally,<br />

they meet IEC requirements for applications such as:<br />

• Disconnector (lEC 947-2)<br />

• Main Switch (lEC 204-1)<br />

• Emergency Off (lEC 204-1)<br />

• Revision Service Switch (lEC 947)<br />

<strong>KT7</strong> <strong>Motor</strong> <strong>Circuit</strong> <strong>Controllers</strong> cannot be applied in North America as<br />

circuit breakers, since they do not meet the UL specifications for circuit<br />

breakers (UL 489).<br />

<strong>Manual</strong> Starter Applications — UL/CSA<br />

<strong>KT7</strong> <strong>Motor</strong> <strong>Circuit</strong> <strong>Controllers</strong> are an excellent choice for manual<br />

starting applications. As UL/CSA listed manual motor controllers, they<br />

provide motor overload protection, however, a separate short-circuit<br />

protective device must still be used. The fuse or circuit breaker used for<br />

the short-circuit protection may be sized to the maximum allowable per<br />

NEC Article 430-52 in the U.S., and CEC Rule 28-200 in Canada. The<br />

<strong>KT7</strong> as a manual motor starter is available in a general purpose enclosure,<br />

water tight enclosure or Type 7/9 enclosure. Undervoltage or shunt<br />

trip relays are also available.<br />

Traditional Group <strong>Motor</strong> Applications<br />

UL/CSA<br />

<strong>KT7</strong> <strong>Motor</strong> <strong>Circuit</strong> <strong>Controllers</strong> are also UL/CSA listed as manual starters<br />

for use in Group <strong>Motor</strong> installations. This listing (and application) has<br />

been the most popular in the United States because of the reduced panel<br />

space and cost savings it provides.<br />

NEC article 430-52 states that each motor must have a Branch <strong>Circuit</strong><br />

Protective Device (BCPD) consisting of a fused disconnect, fuse block &<br />

set of fuses, or a circuit breaker. A typical circuit is illustrated in Figure 1.<br />

Figure 1<br />

Classic Group <strong>Motor</strong> <strong>Circuit</strong> (NEC 430-52)<br />

Even though this method is highly effective and widely used, it has<br />

several drawbacks.<br />

• Breakers or fuse blocks for each motor circuit are<br />

expensive<br />

• The panel space required to house many components like this is<br />

substantial<br />

• Installations of this type are labor intensive and therefore<br />

more costly<br />

NEC 430-53 [CEC 28-206] however, provides several exceptions to 430-<br />

52 [CEC 28-204] that allow you to connect a group of motors under<br />

one BCPD. These exceptions can be found under:<br />

• 430-53(a) - For <strong>Motor</strong>s 1 HP or Less<br />

• 430-53(b) - The Smallest <strong>Motor</strong> is Protected<br />

• 430-53(c) - Other Group Installations<br />

For example, Figure 2 illustrates how a circuit would look utilizing provision<br />

(a) or (b) above. What was once three branch circuits, with three<br />

BCPD’s, is now one branch circuit with one BCPD.<br />

Figure 2<br />

NEC Article 430-53 circuitry without <strong>KT7</strong><br />

Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />

Apps.<br />

F82<br />

Discount Schedule A-1


Application Notes<br />

Series <strong>KT7</strong> <strong>Motor</strong> <strong>Circuit</strong> <strong>Controllers</strong><br />

Methods of Applying <strong>KT7</strong> <strong>Motor</strong> <strong>Circuit</strong> <strong>Controllers</strong> (continued)<br />

Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />

It appears that the exceptions in 430-53 address the expensive drawbacks<br />

to having one BCPD for each motor. Expensive fuses (or circuit breakers)<br />

have been eliminated. Panel space has been significantly reduced, as well<br />

as, the labor to install the circuit.<br />

Unfortunately, NEC 430-53 (a) or (b) [CEC 28-602 (3)(b)] limits the<br />

group to a few small motors. However, by applying the <strong>KT7</strong> under 430-<br />

53 (c) (Figure 3), the problems associated with 430-53 (a) and (b) are<br />

overcome.<br />

Figure 3<br />

Article 430-53 <strong>Circuit</strong>ry With <strong>KT7</strong><br />

• Only one fuse block (or circuit breaker) is used as the BCPD<br />

• Panel size has been significantly reduced<br />

• Wiring and installation time has been significantly reduced<br />

• We have assured protection against low level faults that the BCPD<br />

would pass<br />

• Larger horsepower motors can be grouped with smaller ones<br />

Group Installation under 430-53(c) requires that the BCPD be calculated<br />

and either supplied within the control panel or, if mounted<br />

externally, the BCPD value must be specified by a label within the panel.<br />

Always refer to the NEC code before applying the <strong>KT7</strong> in Group <strong>Motor</strong><br />

Installations.<br />

As stated earlier, Group Installations are the most popular applications<br />

for KTA <strong>Motor</strong> <strong>Circuit</strong> <strong>Controllers</strong> in North America. They greatly reduce<br />

cost when compared to using fuses or circuit breakers in each motor<br />

branch circuit.<br />

<strong>Motor</strong> Disconnecting Applications - UL/CSA<br />

The new <strong>KT7</strong> <strong>Motor</strong> <strong>Circuit</strong> <strong>Controllers</strong> are also UL/CSA listed as<br />

manual motor controllers with the optional approval “Suitable for use as<br />

a motor disconnect.” This UL Listing (UL508, Part III) is new in 1999<br />

and allows <strong>KT7</strong>s to meet the requirements for applications as “at-motor”<br />

disconnects. All manual starters used in such applications must be<br />

marked as “Suitable for use as a motor disconnect”. The <strong>KT7</strong> can be used<br />

in an enclosure with a lockable handle as a manual motor starter and is<br />

an approved means of motor disconnect.<br />

Under the provisions of UL508 Part III, a <strong>Manual</strong> <strong>Motor</strong> Controller can<br />

be labeled “Suitable for use as motor disconnect” and does not require<br />

compliance with UL 98 Disconnect Rules. The primary difference between<br />

UL98 and UL 508 Part III is that the <strong>Manual</strong> <strong>Motor</strong> Controller must bear<br />

a maximum KAIC rating. This rating must be considered in the application<br />

of <strong>KT7</strong> as a motor disconnect.<br />

Corresponding to this new section of UL, the NEC code Article 430-109<br />

a1b6 [CEC 28-602 (3)(b)] permits the use of a manual motor controller<br />

when installed between the BCPD and the motor.<br />

SeIf-Protected <strong>Manual</strong> Combination Starter<br />

Applications (Type E) - UL/CSA<br />

UL508, Part IV, Sections A–E (17th Edition) cover combination motor<br />

controllers that provide a disconnecting means, a load switching means,<br />

overload and short-circuit protection all incorporated within the same<br />

device or assembly. Under these provisions, the new <strong>KT7</strong> <strong>Motor</strong> <strong>Circuit</strong><br />

<strong>Controllers</strong>, with improved current limiting and breaking capacity<br />

(KAIC rating), are now UL/CSA Listed as self-protected (Construction<br />

Type E) manual combination motor controllers. This Type E rating<br />

eliminates the need for individual branch fuses (per UL 198) or a thermal-magnetic<br />

circuit breaker or magnetic-only circuit breaker (per UL<br />

489) as the Branch <strong>Circuit</strong> Protection Device (BCPD). See Figure 4.<br />

Figure 4<br />

Classic Combo Starter (NEC Article 430-52)<br />

Further, the Type E rating eliminates the need for a disconnecting means<br />

(per UL 98) for enclosed and dead-front switches or UL 1087 molded<br />

case switches or UL 489 molded case circuit breakers.<br />

Corresponding to this UL Type E rating, NEC code (Article 430-52<br />

c6) now allows a self-protected combination controller to be used as the<br />

BCPD instead of the classic devices listed in Table 430-152.<br />

Simply stated this new Type E listing allows the <strong>KT7</strong> <strong>Manual</strong> Combination<br />

<strong>Motor</strong> <strong>Controllers</strong> to be used as short-circuit protection, overload<br />

protection and as the motor disconnect on motor branch circuits. See<br />

Figure 5.<br />

F<br />

<strong>Motor</strong> <strong>Circuit</strong><br />

<strong>Controllers</strong><br />

Apps.<br />

Discount Schedule A-1<br />

F83


Application Notes<br />

Series <strong>KT7</strong> <strong>Motor</strong> <strong>Circuit</strong> <strong>Controllers</strong><br />

Methods of Applying <strong>KT7</strong> <strong>Motor</strong> <strong>Circuit</strong> <strong>Controllers</strong> (continued)<br />

F<br />

<strong>Motor</strong> <strong>Circuit</strong><br />

<strong>Controllers</strong><br />

Apps.<br />

Figure 5<br />

<strong>KT7</strong> <strong>Manual</strong> <strong>Motor</strong> Controller and “At motor” Disconnect<br />

It should be noted that <strong>KT7</strong> <strong>Manual</strong> <strong>Motor</strong> <strong>Circuit</strong> Controller, when listed as<br />

self-protected (Type E) device, is rated for Wye-connected power systems for<br />

voltages above 240 volts (i.e. 480Y / 277 volts common in the United States or<br />

600Y/ 347 volts common in Canada).<br />

Effective July 16, 2001<br />

UL made changes to its specifications for self-protected Type E combination<br />

controllers. Among them is a required increase in space between<br />

line side terminals, which directly affects <strong>KT7</strong> controllers in specific<br />

applications.<br />

<strong>KT7</strong> controllers used as Branch <strong>Circuit</strong> Protection Devices (BCPDs)<br />

in Type E applications will be required to meet the new specifications,<br />

provided they were produced after July 16, 2001. <strong>KT7</strong>s produced prior<br />

to that date (including those currently in inventory) may be sold and<br />

installed without alteration. <strong>KT7</strong> controllers applied as manual motor<br />

starters, or part of a group installation, are exempt from the new requirement,<br />

regardless of production date.<br />

• <strong>KT7</strong> controllers produced prior to July 16, 2001, will be used in CL7,<br />

CK7, enclosed <strong>KT7</strong>, CX7, or any custom control panel without the new<br />

terminal adaptors, as allowed by UL, until inventory is depleted.<br />

• All CL7, CK7, enclosed <strong>KT7</strong> and CX7 starters assembled with new <strong>KT7</strong><br />

controllers (with locking notch) in our Houston or Mississauga facilities<br />

will include the new terminal adaptors. No list price change will be made<br />

to these assemblies.<br />

• When applicable, all assemblies shipped from the factory will be Type E<br />

compliant with the change effective July 16, 2001.<br />

Individual Combination Starter Applications<br />

The next logical step is to combine a CA7 contactor to the new (Type E)<br />

self-protected manual combination <strong>KT7</strong> controller. The <strong>KT7</strong> starter provides<br />

the overload and short circuit protection, as well as, the disconnecting<br />

function for the motor, while the CA7 contactor allows for remote<br />

operation via pushbuttons. By contrast, the traditional fusible combination<br />

starter consists of an L10 fusible disconnect switch, short-circuit<br />

protection (alternately an MCP or MCCB), a contactor for remote<br />

operation and a CEP7 overload relay (see Figure 4). The <strong>KT7</strong> Type E<br />

manual controller + CA7 contactor combination can now be compared<br />

with a traditional fusible or circuit breaker Combination Starter including<br />

the means of disconnect.<br />

<strong>KT7</strong><br />

<strong>Motor</strong> <strong>Circuit</strong><br />

Controller<br />

(disconnect)<br />

CA7<br />

Contactor<br />

Figure 6<br />

Type E Combo <strong>Motor</strong> Controller<br />

(starter) and “At motor” Disconnect<br />

(NEC Article 430-52 (c6)<br />

Multi-motor Starter Combination<br />

Applications<br />

The <strong>KT7</strong> Construction Type E rating also eliminates concern for all of<br />

the NEC 430-53 [CEC 28-206] rules for installations involving multiple<br />

motor starters in a single control panel. The result is maximum flexibility<br />

and minimum panel size without the restrictive and cumbersome rules<br />

involved with typical multi-motor (Group Installation) applications.<br />

This means that the main fuses or circuit breaker are no longer necessary<br />

to meet the requirement of a Group Installation Branch<br />

<strong>Circuit</strong> Protection Device (BCPD). A non-fused disconnect may be<br />

needed to meet the safety disconnect rules for the multi-motor starter<br />

control panel. It is important to separate the code requirements for<br />

BCPD’s from the safety codes requiring a panel disconnect to be “in<br />

sight and within 50 feet” to protect the maintenance electrician. <strong>KT7</strong>s<br />

perform the function of BCPD’s under the Type E combination motor<br />

controller approval and may simply be selected according to the motor<br />

full-load current with consideration for the potential fault-current.<br />

Figure 7<br />

Multi-motor Starter Panel using <strong>KT7</strong> as Type E Combo Starter (B.C.P.D.s)<br />

per NEC Article 430-52 (c6)<br />

Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />

F84<br />

Discount Schedule A-1


Application Notes<br />

Series <strong>KT7</strong> <strong>Motor</strong> <strong>Circuit</strong> <strong>Controllers</strong><br />

Methods of Applying <strong>KT7</strong> <strong>Motor</strong> <strong>Circuit</strong> <strong>Controllers</strong> (continued)<br />

Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />

Short-circuit Coordination<br />

The concept of Type 1 and Type 2 coordination are European based but<br />

are certainly not new to the North American market. Fuse companies<br />

have been at the forefront of advancing the concepts and advantages of<br />

Type 2 protection. An appreciation for the advancements offered by selfprotected<br />

combination motor controllers like <strong>KT7</strong> must start with a firm<br />

understanding of Type 1 and Type 2 protection versus Construction Type<br />

E standards.<br />

Type 1<br />

• Under short-circuit conditions, the contactor or<br />

starter shall cause no danger to persons or installation.<br />

• Damage to the contactor and the overload relay is acceptable.<br />

• It may not be suitable for further service without repair and<br />

replacement of parts.<br />

A UL listing of a device or combination of devices like a contactor and<br />

an overload relay would be equivalent to Type 1 coordination in European<br />

(IEC) terminology.<br />

Type 2<br />

• Under short-circuit conditions, the contactor or starter shall<br />

cause no danger to persons or installation and shall be suitable<br />

for further use.<br />

• The risk of contact welding is recognized, in which case the<br />

manufacturer shall indicate the measures to be taken in regards<br />

to maintenance of the equipment.<br />

Most of the above is European terminology that has worked its way into<br />

North American terminology.<br />

UL508E is the UL “Outline of Investigation for Type 2 Coordination.”<br />

It is important to note that UL508E is NOT the same as Construction<br />

Type E Self-protected Combination <strong>Motor</strong> <strong>Controllers</strong> (which falls<br />

under the UL508 Safety Standard for Industrial Control in Section 76 as<br />

we have outlined). This means that UL does not give a “Listing” under<br />

UL508E but rather is a performance standard and not a safety issue.<br />

Companies who publish Type 2 coordination application tables in accordance<br />

with investigation procedures outlined in UL508E must be backed<br />

by self certified tests to verify compliance.<br />

Type 1 and Type 2 coordination have historically been applied to the<br />

combination of a circuit breaker or a set of fuses protecting a contactor<br />

(i.e.: CA7) and an overload (i.e.: CEP7 or CT7). If you select a particular<br />

UL approved contactor and UL Approved overload from the standard<br />

selection tables in our catalog then you have Type 1 coordination. Similarly,<br />

when you combine a CA7 contactor with a <strong>KT7</strong> Type E <strong>Manual</strong><br />

Self-protected Combination Controller by selecting from standard<br />

<strong>KT7</strong> selection tables then you may only have Type 1 protection for the<br />

combination. If your customer wants Type 2 protection then we supply<br />

coordination tables. You must go to the Type 2 protection tables in the<br />

technical section of the <strong>KT7</strong> literature to insure Type 2 protection.<br />

Type E<br />

Construction Type E Self-protected Combination <strong>Motor</strong> <strong>Controllers</strong><br />

• Do not require branch circuit short circuit protective device (fuse or<br />

circuit breaker) upstream<br />

• Includes coordinated overload and short circuit protection<br />

• No welding of contacts is allowed<br />

• Incorporates a motor disconnect rating<br />

• Includes an endurance standard after interrupting a short-circuit<br />

exceeding that specified for Type 2 (UL508E).<br />

This means the test for self-protected combination controllers is more<br />

stringent than Type 2; therefore, many people refer to Type E with implication<br />

not only to the construction type as defined under UL508 Part III<br />

Table 76.2 and applied in accordance with NEC 430-52C Option 6 but<br />

also to the type of coordinated short-circuit protection achieved.<br />

Short-circuit coordination is about the level of damage allowed to the<br />

control equipment under a short circuit condition and the speed of<br />

operation is the key to current limitation.<br />

Suitability for Tap Conductor Protection<br />

For several years, the industry has been applying manual motor circuit<br />

controllers in Group Installations under NEC 430-53C. Many of you<br />

have been aware of the vagueness of the current NEC with respect to<br />

NEC 430-53D concerning “Single <strong>Motor</strong> Taps.” The 2002 NEC added<br />

a new provision which clarifies the sizing of wires in a Group Installation<br />

where the wires feeding each motor circuit controller is considered to be<br />

a tap conductor<br />

NEC-430-53-D-1 restricts the wire feeding the motor circuit controller<br />

to be equal to the wire connected to the BCPD which is extremely limiting.<br />

NEC-430-53-D-2 allows reduction of the sizing of the wire leading<br />

to the BCPD to not less than 1/3 of the wire connected to the B.C.P.D.<br />

Since most 25 ampere frame motor circuit controller only allow for #10<br />

wire maximum (which is rated for 40 amperes) per UL508A “Internal<br />

Wiring Standard”; it follows that the B.C.P.D. must be limited to 120<br />

amperes maximum. Note that the actual FLA connected is limited to<br />

80% of the wire rating. It has been the position of many in the industry<br />

since the introduction of motor circuit controllers in the early 1980’s that<br />

NEC 430-53D was never intended to apply to multiple motor starter<br />

control panels per NEC 430-53C part 1&3, but rather to separately<br />

mounted units with wire duct and gutter taps as described in NEC 430-<br />

53C part 2. This claim was largely based on the maximum BCPD rating<br />

given to Group Rated <strong>Controllers</strong> under UL508 which often exceed the<br />

120 ampere wire limits. The 2002 NEC further clarified that wire size inside<br />

the multiple motor starter panel under Group Installation is covered<br />

by the provisions of Single <strong>Motor</strong> Taps under NEC430-53D.<br />

F<br />

<strong>Motor</strong> <strong>Circuit</strong><br />

<strong>Controllers</strong><br />

Apps.<br />

Discount Schedule A-1<br />

F85


Application Notes<br />

Series <strong>KT7</strong> <strong>Motor</strong> <strong>Circuit</strong> <strong>Controllers</strong><br />

F<br />

<strong>Motor</strong> <strong>Circuit</strong><br />

<strong>Controllers</strong><br />

Methods of Applying <strong>KT7</strong> <strong>Motor</strong> <strong>Circuit</strong> <strong>Controllers</strong> (continued)<br />

The 2002 NEC has new provisions for Single <strong>Motor</strong> Taps under Section<br />

430-53D-3, which clearly provides for sizing motor circuit controller<br />

wires at 1/10 if the length does not exceed 10 feet. This means most 25<br />

ampere frame motor circuit controller that only allow for #10 wire maximum<br />

might be as large as 400 amperes. Further that 45 ampere frame<br />

motor circuit controllers that allow for #4 wire maximum (which is rated<br />

for 105 amperes) might be as large as 1050 amperes. It should be noted<br />

that mini-bus bars are often used to inter-connect the line side of motor<br />

circuit controllers may increase the capacity of the allowable wire size.<br />

This change in the 2002 NEC does require some additional testing of the<br />

motor circuit controller under UL508 in order to mark the device “Suitable<br />

for Tap Conductor Protection in a Group Installation.” The testing<br />

associated with single motor taps is nearly as difficult as those associated<br />

with the test for Self-protected Combination <strong>Motor</strong> <strong>Controllers</strong> (described<br />

elsewhere in this white paper). This means that the Tap Conductor<br />

Protection ratings may well align with the ratings for Self-protected<br />

Combination <strong>Motor</strong> <strong>Controllers</strong>.<br />

It is the opinion of this writer that the strict enforcement of the wire sizing<br />

options defined by NEC 430-53D-1, -2, or -3 will force the industry<br />

to apply Self-protected Combination <strong>Motor</strong> <strong>Controllers</strong> (Construction<br />

Type E or Type F) in multiple motor starter panels under the provisions<br />

of NEC 430-52-C- 6 as opposed to applying simple Group Rated<br />

<strong>Manual</strong> <strong>Motor</strong> <strong>Circuit</strong> <strong>Controllers</strong> under Group Installations as defined<br />

under NEC 430-53-C.<br />

Assemblies Using <strong>KT7</strong><br />

Since devices like KTA7 do not include a magnetic coil contactor in the<br />

assembly, they are considered to be manual motor controllers. If you are<br />

building a multi-motor starter panel you probably need to provide for<br />

remote control and so you add a contactor to the assembly. Sprecher +<br />

Schuh has combined the <strong>KT7</strong> Self-protected Combination Controller<br />

(Construction Type E) into assemblies with appropriately sized contactors.<br />

These assemblies are available in three varieties:<br />

• CL4 = <strong>KT7</strong> + Connector + CA4 Mini-contactor<br />

• CL7 = <strong>KT7</strong> + Connector + CA7 Contactor<br />

• CK7 = <strong>KT7</strong> + CA7 mounted on a DIN adapter socket with<br />

terminal blocks<br />

CL4 and CL7 use connectors (i.e: <strong>KT7</strong>-25S-PEC23) to mate the <strong>KT7</strong><br />

with CA4 and CA7 contactors. Sprecher + Schuh is pleased to announce<br />

that we now have cUL Approval of our –PEC and –PNC connectors.<br />

The recognition of these connectors paves the way to testing and approval<br />

of assemblies using <strong>KT7</strong>.<br />

Type E Self-protected Combination <strong>Motor</strong><br />

Controller Assemblies<br />

An assembly of a Construction Type E <strong>KT7</strong> <strong>Manual</strong> Controller plus a<br />

contactor can be tested as a Self-protected Combination Controller. This<br />

means the assembly must meet all of the same rigid standards including<br />

Type E coordination as described above. Sprecher + Schuh provides additional<br />

tables showing the KAIC ratings of CK7 starters already approved<br />

by UL as Type E assemblies as well as the CL4 & CL7 ratings that are<br />

pending UL approval at the time of this printing.<br />

Type F Combination <strong>Motor</strong> <strong>Controllers</strong><br />

Manufacturers of Construction Type E controllers have been working<br />

closely with UL concerning the addition of a Construction Type F Combination<br />

<strong>Motor</strong> Controller to their specifications and test procedures.<br />

Recently UL did add Type F to UL508 Part III Section 76. Construction<br />

Type F is defined as a Type E <strong>Manual</strong> Self-protected Combination<br />

Controller combined with a magnetic contactor but allowing damage to<br />

the contactor under a short circuit. The damage allowed to the contactor<br />

is similar to that allowed to Construction Type A, B, C or D Combination<br />

<strong>Starters</strong>, which are circuit breakers, fused disconnect, magnetic<br />

only circuit breaker or motor circuit protectors (MCP) combined with a<br />

standard contactor and overload relay better known as the classic Combo<br />

<strong>Starters</strong>.<br />

It is important to point out that you start with a UL Approved Type E<br />

<strong>Manual</strong> Self-protected <strong>Motor</strong> controller and the contactor as an assembly<br />

but test to the same standards as Type 1 protection (just as you would<br />

for a Classic Type A-D Combo). UL has chosen to call this new device a<br />

Combination <strong>Motor</strong> Controller which is more exactly defined as Construction<br />

Type F under to UL508 Part III Section 76.<br />

Note that the Type F designation ‘Combination <strong>Motor</strong> Controller’ is<br />

missing the term ‘Self-protected’ which is reserved for an assembly that<br />

is fully Type E Approved as described above. This means that Type E<br />

assemblies are superior to Type F assemblies with respect to coordinated<br />

protection. Both Type F and Type E are valid selections for customers to<br />

make an informed price versus performance choice.<br />

Once again, if the customer wants Type 2 protection, the manufacturer<br />

must back their recommendations with self-certify testing. Sprecher +<br />

Schuh provides additional tables for the customer to select Type 2 KAIC<br />

ratings for Type F Combination <strong>Motor</strong> <strong>Controllers</strong> in the technical<br />

data section of this chapter. It might be said that Construction Type F<br />

Coordination Type 2 ratings are very close to those of Type E. It is important<br />

to note that the difference is that Type E provides the assurance<br />

of an endurance standard after interrupting a short-circuit exceeding that<br />

specified for Type 2 (UL508E).<br />

In short, you could say that Type F1 is good, Type F2 is better and<br />

Type E is the best.<br />

Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />

Apps.<br />

F86<br />

Discount Schedule A-1


Application Notes<br />

Series <strong>KT7</strong> <strong>Motor</strong> <strong>Circuit</strong> <strong>Controllers</strong><br />

Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />

Methods of Applying <strong>KT7</strong> <strong>Motor</strong> <strong>Circuit</strong> <strong>Controllers</strong> (continued)<br />

A Note About UL1077 Mini-<strong>Circuit</strong> Breakers<br />

All too often we see UL1077 DIN rail mounted Mini-circuit breakers<br />

applied as branch circuit short-circuit protection ahead of a standard<br />

contactor and overload relay. UL1077 Supplemental <strong>Circuit</strong> Breakers<br />

were never intended to replace UL489 Approved <strong>Circuit</strong> Breakers as<br />

short-circuit protection for a motor branch circuit. It is important for<br />

customers who have been employing the use UL1077 circuit breakers<br />

to “protect” motor circuits that the practice is not approved for this purpose<br />

nor is it in compliance with NEC 430-52. Sprecher + Schuh sells<br />

UL1077 Mini-circuit breakers as well <strong>KT7</strong> <strong>Motor</strong> <strong>Circuit</strong> controllers<br />

and it our desire to help customers apply each in accordance with applicable<br />

codes and standards. Please reference our technical application<br />

notes for the proper application of UL1077 Mini-CBs.<br />

There are UL489 Approved Mini-CBs in the marketplace that can be applied<br />

on 240 volt motor applications in accordance with UL and NEC.<br />

Note that these 240 volt UL489 circuit breakers are often seen improperly<br />

applied to 480 volt applications. This DOES NOT comply with UL<br />

and NEC as would the KTA7 <strong>Motor</strong> <strong>Circuit</strong> Controller, which can be<br />

applied for this purpose in applications up to 600 volts.<br />

It should be noted that UL489 Mini-CB’s do not comply with UL508<br />

as an overload relay. Therefore anyone applying a UL489 Mini-CB must<br />

also add a true overload relay to each motor circuit.<br />

Neither UL1077 or UL489 Mini-CBs have the ability to interrupt a high<br />

ampere short-circuit with the speed of a <strong>KT7</strong> <strong>Motor</strong> <strong>Circuit</strong> Controller,<br />

nor do they have the KAIC withstand rating, the ability to provide Type<br />

2 coordination and certainly not Construction Type E approvals or level<br />

of equipment protection.<br />

For additional information concerning the proper application of UL1077<br />

Mini-CB’s, please refer to our White Paper located in the Mini-CB’s section<br />

of the Sprecher + Schuh catalog.<br />

Summary<br />

<strong>KT7</strong> can be applied as a:<br />

• <strong>Manual</strong> <strong>Motor</strong> Controller<br />

• Group Installation Overload Relay<br />

• <strong>Manual</strong> Self-Protected Combination <strong>Motor</strong> Controller (Type E)<br />

CL4, CL7 and CK7 can be applied as a:<br />

• Self-Protected Combination <strong>Motor</strong> Controller assembly (Type E)<br />

• Combination <strong>Motor</strong> Controller (Type F)<br />

The main fuses or circuit breaker are no longer necessary to meet the<br />

requirement of a Group Installation BCPD. A label within the panel<br />

specifying the BCPD outside the panel is a thing of the past. Multi-motor<br />

starter panels using the new <strong>KT7</strong> verses Sprecher + Schuh’s previous<br />

<strong>Motor</strong> <strong>Circuit</strong> Controller (KTA3) probably won’t look much different.<br />

The real difference is the NEC rules applied to accomplish the task, along<br />

with an increased level of KAIC Type 2 protection against the possibility<br />

of a short-circuit fault.<br />

Applying these state-of-the-art controllers properly in North America<br />

requires a working knowledge of UL, CSA, and NEC. It is our objective<br />

to assist customers in keeping pace with developments that can impact<br />

the cost effective protection of their control systems, reduce downtime<br />

and increase production for their customers. We encourage customers<br />

to contact their local Sprecher + Schuh representative or the factory to<br />

discuss issues about applications of these devices.<br />

F<br />

<strong>Motor</strong> <strong>Circuit</strong><br />

<strong>Controllers</strong><br />

Apps.<br />

Discount Schedule A-1<br />

F87


KTA3-25<br />

(Now obsolete)<br />

Sprecher + Schuh <strong>KT4</strong> has replaced the KTA3-25.<br />

Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />

<strong>KT4</strong> <strong>Manual</strong> <strong>Motor</strong> Starter


<strong>KT4</strong> <strong>Manual</strong> <strong>Motor</strong> <strong>Starters</strong><br />

Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />

<strong>Manual</strong> <strong>Motor</strong> Staters – General Description ................................................................................. F90<br />

Quick Selection Guide ................................................................................................................... F91<br />

Accessories .............................................................................................................................F92-95<br />

Contact Blocks ........................................................................................................................ F92<br />

Adaptor Plates ......................................................................................................................... F92<br />

Release Modules ..................................................................................................................... F93<br />

Connecting Modules ................................................................................................................ F93<br />

Mounting ................................................................................................................................ F94<br />

Enclosures .............................................................................................................................. F94<br />

Push Button Sets ..................................................................................................................... F94<br />

Indicator Lights ....................................................................................................................... F94<br />

Bus Bars ................................................................................................................................. F95<br />

Supply Block ........................................................................................................................... F95<br />

Space Cover ............................................................................................................................ F95<br />

Explosion Proof <strong>Manual</strong> Starter Type EV3 ........................................................................................96<br />

Technical Information ...............................................................................................................F97-99<br />

Time Current Curves ................................................................................................................... F100<br />

Diagrams .................................................................................................................................... F101<br />

Dimensions ..........................................................................................................................F102-103<br />

F<br />

<strong>Motor</strong> <strong>Circuit</strong><br />

<strong>Controllers</strong><br />

<strong>KT4</strong><br />

F89


F<br />

<strong>Motor</strong> <strong>Circuit</strong><br />

<strong>Controllers</strong><br />

<strong>KT4</strong><br />

<strong>Manual</strong> <strong>Motor</strong><br />

Starter<br />

Ideal for use as a manual<br />

starter<br />

The <strong>KT4</strong> is a manual motor starter<br />

that employs the features of power<br />

switching, thermal overload protection<br />

and control circuit signaling in<br />

one compact unit. This manual motor<br />

starter has the advantage of a high<br />

speed magnetic trip mechanism which<br />

limits the let-through current under<br />

short-circuit conditions. The <strong>KT4</strong><br />

can be supplied with field installable<br />

shunt trip or an under voltage trip<br />

unit which exceeds the capabilities of<br />

the classic manual motor starter. This<br />

manual motor starter is available in a<br />

variety of enclosures including general<br />

purpose, watertight and explosion<br />

proof (the most compact on the market<br />

today).<br />

<strong>KT4</strong> Reduces panel space<br />

and saves money in Group<br />

<strong>Motor</strong> Installations<br />

The <strong>KT4</strong> can eliminate the need for<br />

larger and more expensive fuse blocks<br />

and fused disconnects, or circuit<br />

breakers. The potential cost savings in<br />

group motor installations according<br />

NEC 430-53c can be as much as 35%<br />

over conventional methods of branch<br />

circuit protection. And, because so<br />

many features are combined into one<br />

small unit, panel space can be slashed<br />

by as much as 60%.<br />

In addition, the <strong>KT4</strong> line offers a wide<br />

application range from 0.1 to 16 FLA<br />

in installations up to 600V. For group<br />

motor applications, the <strong>KT4</strong> series has<br />

a 250A group installation rating, with<br />

a withstand rating as high as 42 KAIC.<br />

Excellent short circuit and<br />

thermal overload protection<br />

In the event of a short-circuit, the<br />

contacts are opened by magnetic, nonadjusting<br />

tripping elements in times<br />

approaching 2/1000 of a second. This<br />

results in the extremely rapid build-up<br />

of an arc voltage which limits the current<br />

of the short-circuit to a very low<br />

level. Because of this superb current<br />

limiting capability the let-through<br />

current is significantly reduced and the<br />

potential for damage is limited.<br />

Because each <strong>KT4</strong> is individually<br />

calibrated at the factory for the smallest<br />

and largest current, very accurate<br />

thermal overload protection is also<br />

obtained. In addition, the <strong>KT4</strong> is a<br />

Class 10 device ... it trips within 10<br />

seconds under a locked rotor condition<br />

(6 x FLA). Every <strong>KT4</strong> <strong>Manual</strong> <strong>Motor</strong><br />

Starter is equipped with automatic<br />

ambient temperature compensation,<br />

which continually adjusts to surrounding<br />

temperatures. As a result, trip<br />

times remain constant and accurate.<br />

Accessories add versatility<br />

Whether in group motor installations<br />

or as a manual motor starter, numerous<br />

field installable accessories are<br />

available to enhance the <strong>KT4</strong>’s performance:<br />

● Auxiliary Contact Blocks<br />

– are available for internal or<br />

external mounting providing<br />

signal switching capability for<br />

control circuits.<br />

● Shunt trip and Undervoltage<br />

Release Modules<br />

– provides the ability to re<br />

motely actuate the <strong>KT4</strong> in<br />

emergency situations or<br />

continuously monitor the line<br />

voltage.<br />

●<br />

Enclosures – are available in<br />

general protection (IP41),<br />

watertight (IP55), as well as<br />

explosion-proof (Type 7/9)<br />

complete with lockable acces<br />

sories.<br />

● Compact Bus Bar System –<br />

reduces the task of line side wiring<br />

in multiple motor starter installations<br />

which reduces the labor cost<br />

of installation.<br />

Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />

<strong>KT4</strong><br />

F90


<strong>KT4</strong> <strong>Manual</strong> <strong>Motor</strong> Starter<br />

<strong>KT4</strong> <strong>Manual</strong> <strong>Motor</strong> Starter ➊<br />

Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />

Maximum Horsepower ➊➋<br />

Ordering Information ➊<br />

Single Ø ➋<br />

Three Ø<br />

O/L Relay<br />

Ampere<br />

Magnetic<br />

Response<br />

115V 230V 200V 230V 460V 575V Response ➍ Current Catalog Number Price<br />

~ ~ ~ ~ ~ ~ 0.1 - 0.16 1.8 <strong>KT4</strong>-C2A-A16 133<br />

~ ~ ~ ~ ~ ~ 0.16 - 0.25 2.8 <strong>KT4</strong>-C2A-A25 133<br />

~ ~ ~ ~ ~ ~ 0.25 - 0.4 4.4 <strong>KT4</strong>-C2A-A40 133<br />

~ ~ ~ ~ ~ ~ 0.4 - 0.63 6.9 <strong>KT4</strong>-C2A-A63 154<br />

~ ~ ~ ~ 1/2 3/4 0.63 - 1.0 11 <strong>KT4</strong>-C2A-B10 154<br />

~ 1/10 ~ ~ 1 1 1.0 - 1.6 18 <strong>KT4</strong>-C2A-B16 154<br />

1/10 1/6 1/2 3/4 1 1/2 2 1.6 - 2.5 28 <strong>KT4</strong>-C2A-B25 154<br />

1/8 1/3 3/4 1 3 3 2.5 - 4.0 44 <strong>KT4</strong>-C2A-B40 154<br />

1/4 3/4 1 1/2 2 5 5 4.0 - 6.3 69 <strong>KT4</strong>-C2A-B63 154<br />

1/2 1 1/2 2 3 7 1/2 10 6.3 - 10 110 <strong>KT4</strong>-C2A-C10 154<br />

1 2 3 5 10 15 10 - 16 176 <strong>KT4</strong>-C2A-C16 176<br />

Short <strong>Circuit</strong> Ratings ➌<br />

Catalog Number<br />

<strong>Manual</strong> <strong>Motor</strong> Starter / Group Installation Ratings<br />

Short <strong>Circuit</strong> Rating (kA)<br />

Maximum Branch <strong>Circuit</strong><br />

Protection Rating ➎<br />

480V 600V Amperes<br />

<strong>KT4</strong>-C2A-A16 42 42 250<br />

<strong>KT4</strong>-C2A-A25 42 42 250<br />

<strong>KT4</strong>-C2A-A40 42 42 250<br />

<strong>KT4</strong>-C2A-A63 42 42 250<br />

<strong>KT4</strong>-C2A-B10 42 42 250<br />

<strong>KT4</strong>-C2A-B16 42 42 250<br />

<strong>KT4</strong>-C2A-B25 42 10 250<br />

<strong>KT4</strong>-C2A-B40 18 5 250<br />

<strong>KT4</strong>-C2A-B63 18 5 250<br />

<strong>KT4</strong>-C2A-C10 10 5 250<br />

<strong>KT4</strong>-C2A-C16 10 5 250<br />

➊ Horsepower ratings shown are the maximum rating of the switching capacity of<br />

the main contactors. The final selection of the manual starter depends on the<br />

actual motor full load amps and service factor.<br />

Example #1:<br />

For a motor with a service factor of 1.15 or greater, use the motor nameplate full<br />

load amps and choose the motor starter with the appropriate current range.<br />

<strong>Motor</strong> F.L.A. 4.2A<br />

Service Factor x 1.15<br />

Effective Current = 6.3A<br />

Select catalog number <strong>KT4</strong>-C2A-A63<br />

Example #2:<br />

For a motor with a service factor less than 1.15, use the motor nameplate full load<br />

amps times 0.9 and choose the motor starter with the appropriate current range.<br />

<strong>Motor</strong> F.L.A. 4.2A<br />

Service Factor x 1.0<br />

Multiplier x 0.9<br />

Effective Current = 3.78A<br />

Select catalog number <strong>KT4</strong>-C2A-A40<br />

➋ Single phase horsepower ratings are based on wiring the 3 poles of the device in<br />

series.<br />

➌ The <strong>KT4</strong> motor circuit controller is approved for use in group installation according<br />

to NEC 430-53C. Reference Sprecher+Schuh UL file #E54612.<br />

➍ The actual trip current is 120% of the dial setting.<br />

➎ Although UL Testing of <strong>Manual</strong> <strong>Motor</strong> <strong>Starters</strong> allows for Group Installation with<br />

upstream Branch <strong>Circuit</strong> Protection maximum ratings as high as 250 amperes;<br />

it should be noted that NEC 2002 contains new restrictions under NEC 430-53D<br />

“Single <strong>Motor</strong> Taps”. <strong>KT4</strong> should be applied as outlined in NEC 430-53D-1 or 430-<br />

53-D-2 to be in compliance. <strong>KT4</strong> does not qualify as “Tap Conductor Protection” as<br />

required under NEC 430-53-D-3. Please refer to the Application notes located at<br />

the end of the <strong>KT7</strong> section for more details on compliance.<br />

F<br />

<strong>Motor</strong> <strong>Circuit</strong><br />

<strong>Controllers</strong><br />

<strong>KT4</strong><br />

Discount Schedule A-1<br />

F91


Accessories<br />

<strong>KT4</strong> <strong>Manual</strong> <strong>Motor</strong> Starter<br />

F<br />

<strong>Motor</strong> <strong>Circuit</strong><br />

<strong>Controllers</strong><br />

Accessories for <strong>KT4</strong><br />

Accessory Description Wiring Diagram Catalog Number Price<br />

Auxiliary Contact Block (NO)<br />

13<br />

- mounts internally. <strong>KT4</strong>-C-AEA10 15<br />

Auxiliary Contact Block (NO)<br />

- mounts internally, terminal markings<br />

appropriate when also using “PA” type<br />

auxiliary contact.<br />

<strong>KT4</strong>-C-AEA210 15<br />

Auxiliary Contact Block (NC)<br />

11<br />

- mounts internally. <strong>KT4</strong>-C-AEA01<br />

Auxiliary Contact Block (NC)<br />

- mounts internally, terminal markings<br />

appropriate when also using “PA” type<br />

auxiliary contact.<br />

Two pole Auxiliary Contact Block<br />

(NO/NC) - for side mounting. If using<br />

Compact Bus Bar System, choose bus<br />

bar with 54mm spacing<br />

Two pole Auxiliary Contact Block -<br />

(NO/NO) - for side mounting. If using<br />

Compact Bus Bar System, choose bus<br />

bar with 54mm spacing.<br />

Two pole Auxiliary Contact Block<br />

- (NC/NC) - for side mounting. If using<br />

Compact Bus Bar System, choose bus<br />

bar with 54mm spacing.<br />

15<br />

<strong>KT4</strong>-C-AEA201 15<br />

<strong>KT4</strong>-C-ASA11 28<br />

<strong>KT4</strong>-C-ASA20 28<br />

<strong>KT4</strong>-C-ASA02 28<br />

Accessory Description Catalog Number Price<br />

Accessories for <strong>KT4</strong> continued on next page ➟<br />

Adaptor Plate<br />

Provides capability to base mount one <strong>KT4</strong><br />

Locking Fixture<br />

Padlocking attachment for one <strong>KT4</strong>-25. Locks in the OFF position only.<br />

Metal construction. Holds one to three padlocks with 6mm hasps.<br />

14<br />

33<br />

34<br />

12<br />

31<br />

32<br />

13 21<br />

14 22<br />

13 23<br />

14 24<br />

11 21<br />

12 22<br />

<strong>KT4</strong>-C-N12 11<br />

<strong>KT4</strong>-C-M3 11<br />

Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />

<strong>KT4</strong><br />

F92<br />

Discount Schedule A-1


Accessories<br />

<strong>KT4</strong> <strong>Manual</strong> <strong>Motor</strong> Starter<br />

Accessories for <strong>KT4</strong> (continued from previous page)<br />

Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />

Accessory Description Wiring Diagram<br />

Accessory<br />

Undervoltage Release Module<br />

- mounts on right hand side,<br />

Prevents <strong>KT4</strong> from operating<br />

unless voltage is present.<br />

Shunt Release Module<br />

- mounts on right hand side.<br />

Remotely trips the <strong>KT4</strong> .<br />

Accessories for <strong>KT4</strong> continued on next page ➟<br />

Description<br />

Connecting Module ➋<br />

- Provides a solid “wireless”<br />

connection between a <strong>KT4</strong><br />

<strong>Motor</strong> <strong>Circuit</strong> Controller and all<br />

CA4 contactors.<br />

Connecting Module - Provides<br />

a solid “wireless” connection<br />

between a <strong>KT4</strong> <strong>Motor</strong> <strong>Circuit</strong><br />

Controller and a CA7 contactor.<br />

<br />

<br />

<br />

C1<br />

F1<br />

Q1<br />

<br />

Voltage /<br />

Rated Current<br />

AC Coil Voltage Catalog<br />

50 HZ 60 HZ Number<br />

24V<br />

<strong>KT4</strong>-C-UXK<br />

24V <strong>KT4</strong>-C-UXJ<br />

48V <strong>KT4</strong>-C-UXX<br />

110V 110V <strong>KT4</strong>-C-UXKD<br />

110V 120V <strong>KT4</strong>-C-UXD<br />

220...230V 240V <strong>KT4</strong>-C-UXF<br />

240...260V <strong>KT4</strong>-C-UXA<br />

240V 277V <strong>KT4</strong>-C-UXT<br />

400V 460V <strong>KT4</strong>-C-UXN<br />

415V 480V <strong>KT4</strong>-C-UXB<br />

500V 575V <strong>KT4</strong>-C-UXM<br />

24V<br />

<strong>KT4</strong>-C-SXK<br />

24V <strong>KT4</strong>-C-SXJ<br />

48V <strong>KT4</strong>-C-SXX<br />

110V 110V <strong>KT4</strong>-C-SXKD<br />

110V 120V <strong>KT4</strong>-C-SXD<br />

220...230V 240V <strong>KT4</strong>-C-SXF<br />

240...260V <strong>KT4</strong>-C-SXA<br />

240V 277V <strong>KT4</strong>-C-SXT<br />

400V 460V <strong>KT4</strong>-C-SXN<br />

415V 480V <strong>KT4</strong>-C-SXB<br />

500V 575V <strong>KT4</strong>-C-SXM<br />

Catalog Number<br />

Price<br />

12A KCD4 7<br />

Connects CA7-9…23 20A KT3-NW23 12<br />

<br />

C2<br />

Price<br />

65<br />

65<br />

F<br />

<strong>Motor</strong> <strong>Circuit</strong><br />

<strong>Controllers</strong><br />

<strong>KT4</strong><br />

Discount Schedule A-1<br />

F93


Accessories<br />

<strong>KT4</strong> <strong>Manual</strong> <strong>Motor</strong> Starter<br />

Accessories for <strong>KT4</strong> (continued from previous page)<br />

F<br />

<strong>Motor</strong> <strong>Circuit</strong><br />

<strong>Controllers</strong><br />

<strong>KT4</strong><br />

<strong>KT4</strong>-C-EA55<br />

Accessory Description Enclosure Rating Catalog No. Price<br />

Accessory Description Kit Catalog No.<br />

<strong>KT4</strong>-C-MT55<br />

<strong>KT4</strong>-C-MK55<br />

<strong>KT4</strong>-C-EE55<br />

Enclosures for Surface Mounting -<br />

With knockouts for two type “DL” pilot lights. Includes ground<br />

and neutral terminals.<br />

Enclosure for Flush Mounting - includes protective earth<br />

and neutral wire terminals.<br />

Emergency Stop Kit<br />

Twist-To-Release<br />

IN STOCK<br />

NOW<br />

Emergency Stop Kit<br />

Key Release<br />

Kit<br />

Price<br />

<strong>KT4</strong>-C-MT 30<br />

<strong>KT4</strong>-C-MK 48<br />

General Purpose (IP41)<br />

For Use With<br />

<strong>KT4</strong>-C-EA41<br />

Watertight (IP55) <strong>KT4</strong>-C-EA55 90<br />

General Purpose (IP41) <strong>KT4</strong>-C-EE41 30<br />

Watertight (IP55) <strong>KT4</strong>-C-EE55 35<br />

Accessory Description Voltage / Rated Current Catalog No. Price<br />

Indicator Lights - mounting in upper part of<br />

enclosure. Length of connection leads: 180 mm<br />

includes lamp.<br />

Enclosure Locking Fixture - Holds one to three<br />

padlocks with 6mm hasps.<br />

Enclosure Membrane - Replacement membrane.<br />

Includes 4 mounting screws (membrane only, does<br />

not include mounting frame).<br />

➊ <strong>KT4</strong> <strong>Manual</strong> <strong>Motor</strong> Starter Not Included. Consult a Sprecher + Schuh<br />

representative for an assembly including a <strong>KT4</strong>.<br />

green<br />

red<br />

white<br />

yellow<br />

120V<br />

240V<br />

400V<br />

415V<br />

480V<br />

120V<br />

240V<br />

400V<br />

415V<br />

480V<br />

120V<br />

240V<br />

400V<br />

415V<br />

480V<br />

120V<br />

240V<br />

400V<br />

415V<br />

480V<br />

For use with<br />

<strong>KT4</strong>-C-EA41 enclosures<br />

For use with<br />

<strong>KT4</strong>-C-EA55 and<br />

<strong>KT4</strong>-C-EE55 enclosures<br />

<strong>KT4</strong>-LG120<br />

<strong>KT4</strong>-LG240<br />

<strong>KT4</strong>-LG400<br />

<strong>KT4</strong>-LG415<br />

<strong>KT4</strong>-LG480<br />

<strong>KT4</strong>-LR120<br />

<strong>KT4</strong>-LR240<br />

<strong>KT4</strong>-LR400<br />

<strong>KT4</strong>-LR415<br />

<strong>KT4</strong>-LR480<br />

<strong>KT4</strong>-LW120<br />

<strong>KT4</strong>-LW240<br />

<strong>KT4</strong>-LW400<br />

<strong>KT4</strong>-LW415<br />

<strong>KT4</strong>-LW480<br />

<strong>KT4</strong>-LY120<br />

<strong>KT4</strong>-LY240<br />

<strong>KT4</strong>-LY400<br />

<strong>KT4</strong>-LY415<br />

<strong>KT4</strong>-LY480<br />

Assembled<br />

Cat No. ➊<br />

50<br />

28<br />

<strong>KT4</strong>-C-M3E 11<br />

<strong>KT4</strong>-C-N18 5<br />

Price<br />

<strong>KT4</strong>-C-EA41 <strong>KT4</strong>-C-MT-EA41 85<br />

<strong>KT4</strong>-C-EE41 <strong>KT4</strong>-C-MT-EE41 65<br />

<strong>KT4</strong>-C-EA55 <strong>KT4</strong>-C-MT-EA55 125<br />

<strong>KT4</strong>-C-EE55 <strong>KT4</strong>-C-MT-EE55 70<br />

<strong>KT4</strong>-C-EA41 <strong>KT4</strong>-C-MK-EA41 103<br />

<strong>KT4</strong>-C-EE41 <strong>KT4</strong>-C-MK-EE41 83<br />

<strong>KT4</strong>-C-EA55 <strong>KT4</strong>-C-MK-EA55 143<br />

<strong>KT4</strong>-C-EE55 <strong>KT4</strong>-C-MK-EE55 88<br />

IN STOCK<br />

NOW<br />

Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />

F94<br />

Discount Schedule A-1


Accessories<br />

<strong>KT4</strong> <strong>Manual</strong> <strong>Motor</strong> Starter<br />

Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />

Compact Bus Bar System for <strong>KT4</strong><br />

Accessory Description Catalog Number Price<br />

Compact Bus Bar - 45mm spacing<br />

- Bus bar with 45mm spacing accepts<br />

<strong>KT4</strong>’s with or without internally<br />

mounted auxiliary or trip signal contact.<br />

Rated to 65A (UL)/63A (IEC).<br />

Connects two <strong>KT4</strong>’s <strong>KT4</strong>-C-W452 27<br />

Connects three <strong>KT4</strong>’s <strong>KT4</strong>-C-W453 31<br />

Connects four <strong>KT4</strong>’s <strong>KT4</strong>-C-W454 35<br />

Connects five <strong>KT4</strong>’s <strong>KT4</strong>-C-W455 39<br />

Compact Bus Bar - 54mm spacing<br />

- Bus bar with 54mm spacing<br />

accepts <strong>KT4</strong>’s with side mounted<br />

auxiliary contact (type PA-11).<br />

Rated to 65A (UL)/63A (IEC).<br />

Connects two <strong>KT4</strong>’s <strong>KT4</strong>-C-W542 27<br />

Connects three <strong>KT4</strong>’s <strong>KT4</strong>-C-W543 31<br />

Connects four <strong>KT4</strong>’s <strong>KT4</strong>-C-W544 35<br />

Connects five <strong>KT4</strong>’s <strong>KT4</strong>-C-W545 39<br />

Supply Block - Provides connection<br />

from bus bar to power.<br />

Blank Space Cover - Covers bus<br />

bar connections where no <strong>KT4</strong> is<br />

mounted.<br />

<strong>KT4</strong>-C-WT 22<br />

<strong>KT4</strong>-C-WS 3<br />

F<br />

<strong>Motor</strong> <strong>Circuit</strong><br />

<strong>Controllers</strong><br />

<strong>KT4</strong><br />

Discount Schedule A-1<br />

F95


<strong>KT4</strong> <strong>Manual</strong> <strong>Motor</strong> Starter<br />

<strong>KT4</strong> Explosion Proof <strong>Manual</strong> Starter - Type “EV3” ➊<br />

F<br />

<strong>Motor</strong> <strong>Circuit</strong><br />

<strong>Controllers</strong><br />

Class I, Division 1 & 2, Group C & D<br />

Class II, Division 1 & 2, Group #, F & G<br />

Class III<br />

NEMA 7CD & 9EFG<br />

<strong>KT4</strong> Modifications (Factory Assembled)<br />

Single Ø<br />

Description Catalog Number Suffix Adder<br />

Auxiliary Contacts<br />

1 NO - Internal -AEA10 15<br />

1 NC - Internal -AEA01 15<br />

Maximum<br />

Horsepower<br />

Three Ø<br />

115V 230V 200V 230V 460V 575V<br />

1/10 1/6 1/2 3/4 1 1/2 2<br />

1 3 3 5 10 15<br />

O/L Relay<br />

Ampere<br />

Range<br />

Magnetic<br />

Response<br />

Current<br />

Ordering<br />

Information<br />

Catalog Number<br />

Price<br />

0.1 - 0.16 1.8 <strong>KT4</strong>-C2A-A16-EV3 425<br />

0.16 - 0.25 2.8 <strong>KT4</strong>-C2A-A25-EV3 425<br />

0.25 - 0.4 4.4 <strong>KT4</strong>-C2A-A40-EV3 450<br />

0.4 - 0.63 6.9 <strong>KT4</strong>-C2A-A63-EV3 450<br />

0.63 - 1.0 11 <strong>KT4</strong>-C2A-B10-EV3 450<br />

1.0 - 1.6 18 <strong>KT4</strong>-C2A-B16-EV3 450<br />

1.6 - 2.5 28 <strong>KT4</strong>-C2A-B25-EV3 450<br />

2.5 - 4.0 44 <strong>KT4</strong>-C2A-B40-EV3 450<br />

4.0 - 6.3 69 <strong>KT4</strong>-C2A-B63-EV3 450<br />

6.3 - 10 110 <strong>KT4</strong>-C2A-C10-EV3 450<br />

10 - 16 176 <strong>KT4</strong>-C2A-C16-EV3 475<br />

Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />

<strong>KT4</strong><br />

➊ “Feed Through” type conduit hubs provided as standard.<br />

F96<br />

Discount Schedule A-1


Technical Information<br />

<strong>KT4</strong> <strong>Manual</strong> <strong>Motor</strong> Starter<br />

Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />

Technical Information<br />

<strong>KT4</strong>…<br />

Standards Approvals UL 508; CSA22.2; EN/IEC 60947-1/-2/-4/-5-1/<br />

UL, CSA, CE, SEV, Germ. Lloyd, CEBEC, PTB,<br />

DEMKO, SEMKO, SETI, NEMKO, Bureau Veritas,<br />

Lloyd’s Register of Shipping, Maritime Register<br />

of Shipping, RINA, KEMA<br />

Approvals / Markings<br />

CE, cULus Listed<br />

Rated Insulation Voltage<br />

IEC, SEV, VDE0660 [V] 690<br />

UL, CSA [V] 600<br />

Rated Impulse Withstand Voltage<br />

Main circuits<br />

6 kV<br />

Auxiliary circuits<br />

6 kV<br />

Rated Frequency [Hz] 40…60<br />

Rated Operating Current [A] 0.1…16 (11 ranges)<br />

Life<br />

Mechanical [operations] 100,000<br />

<strong>Electric</strong>al [operations] 50,000<br />

Switching Frequency<br />

Max. 30 operating cycles/hour<br />

Ambient Temperature<br />

Storage<br />

-25°C to +80°C<br />

Operation<br />

-25°C to +60°C<br />

Resistance to climatic change<br />

Humid heat<br />

40°C, 92%, 56 days<br />

Alternating climatic conditions<br />

23°C, 83%/40°C, 93%, 56 cycles<br />

Degree of Protection<br />

IP20 (when wired)<br />

Impact Resistance (shock)<br />

50g, 11ms<br />

Vibration Strength<br />

Frequency Range<br />

10…150Hz<br />

In all directions<br />

>7.5g<br />

Overload Protection<br />

Tripping Time Class 10<br />

Phase failure protection<br />

See time/current curve<br />

Temperature Compensation<br />

-20°C… +60°C (70°C=15% current reduction<br />

of upper rated current)<br />

Magnetic Response<br />

11 x Ie max. (fixed setting)<br />

(Ie max. = max value of the setting range)<br />

Total Power dissipation<br />

<strong>Manual</strong> motor starter at rated load [W] 7<br />

Terminal Connections<br />

Type of terminals<br />

Screwdriver Position No. 2/Blade No. 3<br />

1. conductor 1 to 4 mm 2 / 16 to 12 AWG<br />

2. conductor 1 to 4 mm 2 / 16 to 12 AWG<br />

1. conductor 1 to 6 mm 2 / 16 to 12 AWG<br />

2. conductor 1 to 6 mm 2 / 16 to 12 AWG<br />

1. conductor 1.5 to 6 mm 2 / 16 to 12 AWG<br />

2. conductor 1.5 to 6 mm 2 / 16 to 12 AWG<br />

Tightening torque<br />

2 to 2.5 Nm / 18 to 22 fb-in<br />

Mounting Position - <strong>KT4</strong><br />

Weights<br />

Description Catalog Number Weight<br />

<strong>Manual</strong> <strong>Motor</strong> Starter <strong>KT4</strong>-C2A... 290 g<br />

Auxiliary Contact Blocks<br />

for Flush Mounting<br />

<strong>KT4</strong>-C-AEA 12 g<br />

Auxiliary Contact Blocks<br />

for Left-side Mounting<br />

<strong>KT4</strong>-C-ASA 35 g<br />

Undervoltage Release <strong>KT4</strong>-C-UX 104 g<br />

Shunt Release <strong>KT4</strong>-C-SX 100 g<br />

Bus Bar Feeder Terminal <strong>KT4</strong>-C-WT 36 g<br />

<strong>KT4</strong>-C-W452 42 g<br />

<strong>KT4</strong>-C-W453 69 g<br />

<strong>KT4</strong>-C-W454 94 g<br />

Compact Bus Bar<br />

<strong>KT4</strong>-C-W455 119 g<br />

<strong>KT4</strong>-C-W542 45 g<br />

<strong>KT4</strong>-C-W543 76 g<br />

<strong>KT4</strong>-C-W545 104 g<br />

<strong>KT4</strong>-C-W545 135 g<br />

Blank Space Cover <strong>KT4</strong>-C-WS 3.3 g<br />

Emergency-Stop<br />

<strong>KT4</strong>-C-MT g<br />

Push Button<br />

<strong>KT4</strong>-C-MK g<br />

Enclosure for<br />

Surface Mounting<br />

<strong>KT4</strong>-C-EA41 250 g<br />

Enclosure for<br />

Flush Mounting<br />

<strong>KT4</strong>-C-EA55 258 g<br />

Button Membrane<br />

<strong>KT4</strong>-C-EE41 126 g<br />

<strong>KT4</strong>-C-EE55 134 g<br />

Indicator Light <strong>KT4</strong>-L... 10 g<br />

Hut (DIN) rail Adapter<br />

<strong>KT4</strong>-C-N12 16 g<br />

<strong>KT4</strong>-C-M3E 19 g<br />

Locking Arrangement <strong>KT4</strong>-C-M3 11 g<br />

F<br />

<strong>Motor</strong> <strong>Circuit</strong><br />

<strong>Controllers</strong><br />

<strong>KT4</strong><br />

Discount Schedule A-1<br />

F97


Technical Information<br />

<strong>KT4</strong> <strong>Manual</strong> <strong>Motor</strong> Starter<br />

F<br />

<strong>Motor</strong> <strong>Circuit</strong><br />

<strong>Controllers</strong><br />

Technical Information<br />

Specifications of Accessories<br />

<strong>KT4</strong>-C-AEA...<br />

Auxiliary Contact Block for<br />

Flush Mounting<br />

<strong>KT4</strong>-C-ASA...<br />

Auxiliary Contact Block for<br />

Left-side Mounting<br />

Rated Thermal Current I th<br />

at 40°C ambient temperature [A] 6 10<br />

at 60°C ambient temperature [A] 4 6<br />

Contact Class Coordination According to NEMA<br />

(UL/CSA Standards)<br />

[AC] B 600 Standard Pilot Duty B 600 Standard Pilot Duty<br />

[DC] R 300 Light Pilot Duty R 300 Light Pilot Duty<br />

Back-Up Fuses gG, gL [A] 16 16<br />

Rated Supply current [V] 230/240 400/415 500 690 230/240 400/415 500 690<br />

AC-15 [A] 2 1 0.8 0.5 2 1 0.8 0.5<br />

DC-13 [V] 24 48 110 220 24 48 110 220<br />

[A] 2 0.6 0.2 0.1 2 0.6 0.2 0.1<br />

Terminal Parts<br />

Type of terminals<br />

Screwdriver Pozidrive No. 2 / Blade No. 3<br />

1. conductor 0.75 to 2.5 mm2 / 18 to 14 AWG 0.75 to 2.5 mm2 / 18 to 14 AWG<br />

2. conductor 0.75 to 2.5 mm2 / 18 to 14 AWG 0.75 to 2.5 mm2 / 18 to 14 AWG<br />

1. conductor 0.75 to 4 mm2 / 18 to 14 AWG 0.75 to 4 mm2 / 18 to 14 AWG<br />

2. conductor 0.75 to 4 mm2 / 18 to 14 AWG 0.75 to 4 mm2 / 18 to 14 AWG<br />

1. conductor 0.75 to 4 mm2 / 18 to 14 AWG 0.75 to 4 mm2 / 18 to 14 AWG<br />

2. conductor 0.75 to 4 mm2 / 18 to 14 AWG 0.75 to 4 mm2 / 18 to 14 AWG<br />

Tightening torque 1 to 1.5 Nm / 9 to 13 fb-in 1 to 1.5 Nm / 9 to 13 fb-in<br />

<strong>KT4</strong>-C-UX...<br />

Undervoltage Release Unit<br />

for Right-side Mounting<br />

<strong>KT4</strong>-C-SX...<br />

Shunt Release for<br />

Right-side Mounting<br />

<strong>KT4</strong>-C-WT<br />

Supply Block<br />

Actuating Voltage<br />

Pull-in 0.8 to 1.1 x U s<br />

0.7 to 1.1 x U s<br />

Drop-out 0.7 to 0.35 x U s<br />

~<br />

Rated Control Voltage min. 12V 50 Hz, 14V 60 Hz 12V 50 Hz, 14V 60 Hz<br />

max. 600V 50 Hz 600V 50 Hz<br />

On-Time 100 % 100%<br />

Coil Rating Pull-in 8.5 VA, 6 W 8.5 VA, 6 W<br />

Hold 3 VA, 1.2 W 3 VA, 1.2 W<br />

Terminal Parts<br />

Type of terminals<br />

Screwdriver Pozidrive No. 2/Blade No. 3 Pozidrive No. 2/Blade No. 3 Pozidrive No. 2/Blade No. 3<br />

1. conductor 0.75 to 2.5 mm 2 / 18 to 14 AWG 0.75 to 2.5 mm 2 / 18 to 14 AWG 4 to 16 mm 2 / 14 to 6 AWG<br />

2. conductor 0.75 to 2.5 mm 2 / 18 to 14 AWG 0.75 to 2.5 mm 2 / 18 to 14 AWG 4 to 16 mm 2 / 14 to 6 AWG<br />

1. conductor 0.75 to 4 mm 2 / 18 to 14 AWG 0.75 to 4 mm 2 / 18 to 14 AWG 4 to 16 mm 2 / 14 to 6 AWG<br />

2. conductor 0.75 to 4 mm 2 / 18 to 14 AWG 0.75 to 4 mm 2 / 18 to 14 AWG 4 to 16 mm 2 / 14 to 6 AWG<br />

1. conductor 0.75 to 4 mm 2 / 18 to 14 AWG 0.75 to 4 mm 2 / 18 to 14 AWG 4 to 16 mm 2 / 14 to 6 AWG<br />

2. conductor 0.75 to 4 mm 2 / 18 to 14 AWG 0.75 to 4 mm 2 / 18 to 14 AWG 4 to 16 mm 2 / 14 to 6 AWG<br />

Tightening torque 1 to 1.5 Nm / 9 to 13 fb-in 1 to 1.5 Nm / 9 to 13 fb-in 4 Nm / 36 fb-in<br />

<strong>KT4</strong>-C-W45...<br />

Compact Bus Bar<br />

<strong>KT4</strong>-C-W54...<br />

Compact Bus Bar<br />

Rated Insulation Voltage U i<br />

[V] 690 690<br />

Rated Thermal Current I th<br />

[A} 63 63<br />

<strong>KT4</strong>-C-EA41 / -EE41<br />

Enclosure<br />

<strong>KT4</strong>-C-EA55 / -EE55<br />

Enclosure<br />

<strong>KT4</strong>-C-L...<br />

Indicator Light<br />

IP Protection IP41 IP55 (with seal and protective membrane) IP54<br />

Ambient Temperature [°C] - 25...+ 40 - 25...+ 40 ~<br />

Rated Operating Voltage [V] ~ ~ 120, 240, 415, 480<br />

Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />

<strong>KT4</strong><br />

F98<br />

Discount Schedule A-1


Technical Information<br />

<strong>KT4</strong> <strong>Manual</strong> <strong>Motor</strong> Starter<br />

Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />

IEC Performance Data (<strong>KT4</strong>-C2A)<br />

-A16 -A25 -A40 -A63 -B10 -B16 -B25 -B40 -B63 -C10 -C16<br />

Switching of standard three phase motors<br />

AC-2, AC-3<br />

230/240V [kW] ~ ~ ~ 0.06/0.09 0.12 0.18/0.25 0.37 0.55/0.75 1.1/1.5 2.2 3.0/4.0<br />

400/415V [kW] 0.02 0.06 0.09 0.18/.25 0.25 0.37/0.55 .75 1.1/1.5 2.2 3.0/4.0 5.5/7.5<br />

500V [kW] ~ ~ ~ 0.18 0.25/0.37 0.55/0.75 1.1 1.5/2.2 2.5/3.0 4.0/6.3 7.5/10<br />

690V [kW] ~ ~ ~ 0.25 0.37/0.55 0.75/1.1 1.8 2.2/3.0 ~ ~ ~<br />

Back-up fuses<br />

gG, aM, only if Icc > Icu<br />

230/240V [A]<br />

~ ~ ~ ~ 50<br />

400/415V [A] ~ ~ ~ 63 50<br />

No Fuses Required<br />

500V [A] ~ ~ 63 50 50<br />

690V [A] 25 35 ~ ~ ~<br />

Ultimate short-circuit breaking capacity Icu<br />

230/240V [kA] 65 65 65 65 65 65 50 50 50 50 3<br />

400/415V [kA] 65 65 65 65 65 65 50 10 10 8 6<br />

500V [kA] 50 50 50 50 50 50 50 3 10 4.5 4.5<br />

690V [kA] 50 50 50 50 50 50 4.5 2 ~ ~ ~<br />

CSA Performance Data (<strong>KT4</strong>-C2A)<br />

-A16 -A25 -A40 -A63 -B10 -B16 -B25 -B40 -B63 -C10 -C16<br />

Maximum short-circuit current<br />

480V [kA] 42 42 42 42 42 42 42 18 18 10 5<br />

600V [kA] 42 42 42 42 42 42 10 5 5 5 5<br />

<strong>Motor</strong> load<br />

1-phase<br />

115V [HP] ~ ~ ~ ~ ~ ~ 1/10 1/8 1/4 1/2 1<br />

230V [HP] ~ ~ ~ ~ ~ 1/10 1/6 1/3 3/4 1 1/2 3<br />

3-phase<br />

200V [HP] ~ ~ ~ ~ ~ ~ 1/2 3/4 1 1/2 2 3<br />

230V [HP] ~ ~ ~ ~ ~ ~ 3/4 1 2 3 5<br />

460V [HP] ~ ~ ~ ~ 1/2 1 1 1/2 3 5 7 1/2 10<br />

575V [HP] ~ ~ ~ ~ 3/4 1 2 3 5 10 15<br />

Auxiliary Contact & Trip Indicator Contact Development<br />

Contact Open<br />

Contact Closed<br />

Auxiliary Contacts<br />

<strong>KT4</strong>-C-ASA (NO)<br />

<strong>KT4</strong>-C-ASA (NC)<br />

F<br />

<strong>Motor</strong> <strong>Circuit</strong><br />

<strong>Controllers</strong><br />

<strong>KT4</strong><br />

Discount Schedule A-1<br />

F99


<strong>KT4</strong> <strong>Manual</strong> <strong>Motor</strong> <strong>Starters</strong><br />

F<br />

<strong>Motor</strong> <strong>Circuit</strong><br />

<strong>Controllers</strong><br />

<strong>KT4</strong><br />

10000<br />

2 h<br />

1 h<br />

Tripping time t A [s]<br />

1000<br />

100<br />

10<br />

1<br />

0.1<br />

0.01<br />

<strong>KT4</strong>-C2A<br />

Time / current characteristics<br />

asymmetrical<br />

symmetrical<br />

Specified limits in compliance<br />

with IEC 60947-4-1 from the<br />

warm state<br />

0.001<br />

0.1 1 10 100<br />

Multiple of the set current I eF<br />

Dispersion: t A ±20%, I eF ±10%<br />

1)<br />

Mean value from<br />

the cold state<br />

2)<br />

The <strong>KT4</strong>-C2A manual motor starter limits short-circuit current I cc<br />

(prospective shortcircuit<br />

current). I D<br />

is the maximum cut-off current (highest instantaneous value of the<br />

limited short-circuit current). This value is indicated in the following diagram as a<br />

function of the system short-circuit current.<br />

Correspondingly the maximum forward j 2 dt energy is limited. This value is indicated in<br />

the following diagram as a function of the system short-circuited current.<br />

<strong>KT4</strong>-C2A<br />

1) Operating Current of Thermal Releases:<br />

The adjustable inverse bimetal trip reliability protects motors against overloads. The<br />

curve shows the mean operating current at an ambient temperature of 20°C<br />

starting from cold.<br />

In equipment at operating temperature, release time is less than or equal to release<br />

time from the cold state.<br />

2) Operating Current of Magnetic Releases:<br />

Electromagnetic instantaneous releases react at a fixed tripping current.<br />

At the upper thermal release setting, this tripping current is 11 times the set cur<br />

rent.<br />

Current To Be Set:<br />

Thermal releases meet the requirements for a thermal release of a starter in accordance<br />

with IEC 60947-4-1 f. If a different value is specified (such as reduced I e<br />

in motors with an ambient temperature higher than 40°C or a site altitude >2000 m<br />

above sea level), the rated operating current I e<br />

must be adjusted.<br />

Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />

F100<br />

Discount Schedule A-1


<strong>KT4</strong> Wiring Diagrams<br />

<strong>KT4</strong> <strong>Manual</strong> <strong>Motor</strong> Starter<br />

Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />

Single, Two and Three Phase Connection Diagram<br />

F<br />

<strong>Motor</strong> <strong>Circuit</strong><br />

<strong>Controllers</strong><br />

<strong>KT4</strong><br />

Discount Schedule A-1<br />

F101


<strong>KT4</strong> Dimensions<br />

<strong>KT4</strong> <strong>Manual</strong> <strong>Motor</strong> Starter<br />

Dimensions in millimeters except where noted<br />

F<br />

<strong>Motor</strong> <strong>Circuit</strong><br />

<strong>Controllers</strong><br />

1) DIN rail (EN 50022-35)<br />

2) <strong>KT4</strong> w/<strong>KT4</strong>-C-AEA<br />

3) <strong>KT4</strong>-C-ASA<br />

4) <strong>KT4</strong>-C-SXB or <strong>KT4</strong>-C-UXA<br />

<strong>KT4</strong> <strong>Motor</strong> <strong>Circuit</strong> Controller<br />

<strong>KT4</strong>-C-WT<br />

<strong>KT4</strong>-C-N12<br />

<strong>KT4</strong> with Compact Bus Bar<br />

<strong>KT4</strong>-C2A with <strong>KT4</strong>-C-WT<br />

Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />

<strong>KT4</strong><br />

F102<br />

Discount Schedule A-1


Dimensions<br />

<strong>KT4</strong> <strong>Manual</strong> <strong>Motor</strong> Starter<br />

Dimensions in millimeters except where noted<br />

Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />

<strong>KT4</strong>-C-EA55 Enclosure<br />

<strong>KT4</strong> Explosion Proof Starter - Type “EV3”<br />

<strong>KT4</strong>-C-EE41 Enclosure<br />

F<br />

<strong>Motor</strong> <strong>Circuit</strong><br />

<strong>Controllers</strong><br />

<strong>KT4</strong><br />

Discount Schedule A-1<br />

F103


Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />

<strong>Circuit</strong> Protection<br />

Sprecher+Schuh L8 Supplementary Protectors – General Description ............ M2<br />

Series L8 Supplementary Protectors – Trip curve “B” ............................................ M4<br />

Series L8 Supplementary Protectors – Trip curve “C” ............................................ M6<br />

Series L8 Supplementary Protectors – Trip curve “D” ............................................ M8<br />

Accessories .................................................................................................... M10<br />

Technical Information ...................................................................................... M12<br />

Dimensions ..................................................................................................... M17<br />

Sprecher+Schuh L9 Miniature <strong>Circuit</strong> Breakers – General Description .......... M18<br />

Series L9 UL489 <strong>Circuit</strong> Breakers – Trip curve “C” .............................................. M20<br />

Series L9 UL489 <strong>Circuit</strong> Breakers – Trip curve “D” .............................................. M21<br />

Accessories .................................................................................................... M22<br />

Technical Information ...................................................................................... M23<br />

Dimensions ..................................................................................................... M24<br />

<strong>Circuit</strong> Protection Methods ............................................................................... M25<br />

Applying L8 Supplementary Protectors with UL and NEC Guidelines ................ M26<br />

Applying L9 Miniature <strong>Circuit</strong> Breakers with UL and NEC Guidelines ................ M28<br />

Defining <strong>Electric</strong>al Standards .......................................................................... M31<br />

Sprecher + Schuh DIN-rail Mounted Fuse Holders – General Description .... M33<br />

Series FH7 Fuse Holders – Midget Fuses ............................................................ M34<br />

Series FH7 Fuse Holders – Class CC Fuses ......................................................... M35<br />

Series FH7 Fuse Holders – Class J Fuses, 30A .................................................... M36<br />

Series FH7 Fuse Holders – Class J Fuses, 60A .................................................... M37<br />

Fuse Block Selection Guide ............................................................................. M38<br />

M<br />

<strong>Circuit</strong><br />

Protection<br />

M1


M<br />

<strong>Circuit</strong><br />

Protection<br />

Series L8<br />

Supplementary<br />

Protectors<br />

Supplemental short<br />

circuit protection for a<br />

variety of applications<br />

Sprecher+Schuh Series L8 Supplementary<br />

Protectors provide supplemental<br />

overcurrent protection for control<br />

circuits, solenoids, actuators, appliances,<br />

business equipment and a range<br />

of other applications where a high<br />

performance current limiting device is<br />

required. Advanced features and global<br />

approvals make them ideal for use in<br />

equipment installed throughout the<br />

world.<br />

Broad product range<br />

Series L8 Supplementary Protectors are<br />

available in up to 20 different current<br />

ratings from 0.5A to 63A, in one, two<br />

and three pole configurations. Over<br />

180 base models are available with a<br />

full compliment of accessories.<br />

Devices can be used in applications up<br />

to 480V AC and 48V DC with interrupting<br />

capacities up to 10kA.<br />

Safety features provide<br />

enhanced protection<br />

The terminals of Series L8 Supplementary<br />

Protectors provide IP20<br />

protection to guard against accidental<br />

contact with live parts.<br />

To aid troubleshooting, a color-coded<br />

indicator provides positive visual indication<br />

of the device status (green for<br />

OFF, red for ON) and isolation function.<br />

Sprecher+Schuh Supplementary<br />

Protectors also incorporate a trip-free<br />

mechanism - ensuring that the device<br />

operation cannot be defeated by holding<br />

the operator in the ON position.<br />

Easy installation<br />

Sprecher+Schuh Supplementary Protectors<br />

mount on a standard 35mm<br />

DIN-rail. Wire terminals accept<br />

multiple conductors, and bus bars can<br />

be used to quickly distribute power<br />

to many Supplementary Protectors<br />

simultaneously. In addition, power to<br />

the circuit breakers can be fed from<br />

the line or load side.<br />

Global approvals for worldwide<br />

acceptance<br />

Series L8 Supplementary Protectors<br />

are UL Recognized for use in<br />

the United States in accordance with<br />

NFPA 79 (NEC, National <strong>Electric</strong>al<br />

Code). The devices comply with UL<br />

1077 and CSA 22.2 No.235, meeting<br />

the requirements for supplementary<br />

protectors intended for use as overcurrent<br />

protection where branch circuit<br />

protection is not required, or is provided<br />

by another device such as a fuse<br />

or molded case circuit breaker. These<br />

Supplementary Protectors also comply<br />

with IEC 60898 for use in commercial<br />

and residential applications and are CE<br />

marked.<br />

Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />

L8<br />

17.5mm 35mm 52.5mm<br />

(≈11/16˝) (≈1-3/8˝) (≈2-1/8˝)<br />

One Pole Two Pole Three Pole<br />

M2


Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />

Three trip characteristics<br />

All Sprecher+Schuh L8 Supplementary<br />

Protectors are available with three<br />

different tripping characteristics, Type<br />

“B”, “C”, and “D”. The tripping characteristic<br />

defines the device’s speed of<br />

response (trip-time) to various levels of<br />

overcurrent. Figure 1 shows trip-time<br />

versus overcurrent for Type B, C, and<br />

D devices. The time-current characteristics<br />

enable the device to be optimally<br />

matched to the application. For<br />

example, PLC outputs that can only<br />

tolerate minimal overcurrents are best<br />

protected by Supplementary Protectors<br />

with Type B trip characteristics.<br />

Sprecher+Schuh L8 Supplementary<br />

Protectors are also current limiting<br />

- interrupting fault currents within one<br />

half cycle. Current limiting devices<br />

protect circuit components from damage<br />

by reducing the peak let-through<br />

current which causes damaging<br />

magnetic forces and let-through energy<br />

which generates heat.<br />

Compare these advanced features<br />

Box lug terminals accept #18…#4<br />

(1.0…25mm 2 ) wire as standard<br />

Current limiting and interrupting capacity up<br />

to 5kA at 480VAC.<br />

Trip-free mechanism; device operation<br />

cannot be defeated by holding the operator<br />

in the ON position<br />

Color coded indicator provides visual<br />

indication of the device status and isolation<br />

function<br />

Available in one, two and three pole;<br />

one pole + neutral and three pole + neutral<br />

t [sec] t [min]<br />

120<br />

60<br />

20<br />

10<br />

5<br />

2<br />

1<br />

30<br />

10<br />

5<br />

2<br />

1<br />

0.5<br />

0.2<br />

0.1<br />

0.05<br />

0.02<br />

0.01<br />

0.005<br />

0.002<br />

0.001<br />

0.0005<br />

(Curves at 30° C)<br />

1 2 3 4 5 6 7 8 9 10 15 20 30 40 50<br />

I / I N<br />

Figure 1<br />

Sprecher+Schuh Series L8<br />

Supplementary Protector<br />

Trip Characteristics<br />

Type “B” Characteristic<br />

Developed primarily to protect conductors<br />

and low level signal devices such as PLCs.<br />

Instantaneous trip is three to five times<br />

the rated current of the Supplementary<br />

Protector (3~5 x I n ). The fast trip time of<br />

these devices minimizes damage to control<br />

circuit conductors from low-level faults.<br />

Type “C” Characteristic<br />

Developed primarily for applications with<br />

moderate inrush currents such as lighting,<br />

control circuits and coils, computers and<br />

appliances. Instantaneous trip is five to<br />

ten times the rated current of the Supplementary<br />

Protector (5~10 x I n ). The<br />

higher instantaneous trip level prevents<br />

nuisance tripping, and components being<br />

protected can typically withstand higher<br />

fault currents without being damaged.<br />

Type “D” Characteristic<br />

Developed primarily for applications with<br />

high inrush currents, i.e., transformers,<br />

power supplies and heaters. Instantaneous<br />

trip is ten to twenty times the rated current<br />

of the Supplementary Protector<br />

(10~20 x I n ). The high instantaneous<br />

trip level prevents nuisance tripping, and<br />

components being protected can typically<br />

withstand higher fault currents without<br />

being damaged.<br />

Line and load side terminals accept bus bar<br />

connections for reduced costs and more<br />

efficient installation of multiple devices.<br />

Guarded posidrive terminal screws with<br />

finger-safe protection to IEC 947-1<br />

Devices install on standard 35mm DIN-rail<br />

(EN 50022)<br />

Magnetic trip elements provide Type B,<br />

C and D trip characteristics (IEC and EN<br />

60898), while bimetallic elements protect<br />

against slight overloads.<br />

Amp rating and trip curve characteristic<br />

clearly marked on the device for easy<br />

identification<br />

M<br />

<strong>Circuit</strong><br />

Protection<br />

L8<br />

M3


L8 Supplementary Protectors<br />

Trip Characteristic B<br />

M<br />

<strong>Circuit</strong><br />

Protection<br />

Trip Characteristic B (3~5 x I N ) – Resistive or slightly inductive loads<br />

Rated<br />

Current<br />

(A)<br />

Catalog Number<br />

1 Pole 2 Pole 3 Pole<br />

Price<br />

Std.<br />

Pkg. Catalog Number Price<br />

Std.<br />

Pkg. Catalog Number Price<br />

1 L8-1/1/B 36 12 L8-1/2/B 78 6 L8-1/3/B 118 4<br />

2 L8-2/1/B 36 12 L8-2/2/B 78 6 L8-2/3/B 118 4<br />

3 L8-3/1/B 36 12 L8-3/2/B 78 6 L8-3/3/B 118 4<br />

4 L8-4/1/B 36 12 L8-4/2/B 78 6 L8-4/3/B 118 4<br />

5 L8-5/1/B 36 12 L8-5/2/B 78 6 L8-5/3/B 118 4<br />

6 L8-6/1/B 36 12 L8-6/2/B 78 6 L8-6/3/B 118 4<br />

7 L8-7/1/B 36 12 L8-7/2/B 78 6 L8-7/3/B 118 4<br />

8 L8-8/1/B 36 12 L8-8/2/B 78 6 L8-8/3/B 118 4<br />

10 L8-10/1/B 36 12 L8-10/2/B 78 6 L8-10/3/B 118 4<br />

13 L8-13/1/B 36 12 L8-13/2/B 78 6 L8-13/3/B 118 4<br />

15 L8-15/1/B 36 12 L8-15/2/B 78 6 L8-15/3/B 118 4<br />

16 L8-16/1/B 36 12 L8-16/2/B 78 6 L8-16/3/B 118 4<br />

20 L8-20/1/B 38 12 L8-20/2/B 86 6 L8-20/3/B 130 4<br />

25 L8-25/1/B 38 12 L8-25/2/B 88 6 L8-25/3/B 132 4<br />

30 L8-30/1/B 38 12 L8-30/2/B 88 6 L8-30/3/B 132 4<br />

32 L8-32/1/B 40 12 L8-32/2/B 94 6 L8-32/3/B 142 4<br />

40 L8-40/1/B 42 12 L8-40/2/B 98 6 L8-40/3/B 148 4<br />

50 L8-50/1/B 48 12 L8-50/2/B 112 6 L8-50/3/B 170 4<br />

63 L8-63/1/B 56 12 L8-63/2/B 128 6 L8-63/3/B 194 4<br />

Std.<br />

Pkg.<br />

Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />

L8<br />

M4<br />

Discount Schedule B-8


L8 Supplementary Protectors<br />

Trip Characteristic B<br />

Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />

Trip Characteristic B (3~5 x I N ) – Resistive or slightly inductive loads<br />

Rated<br />

Current<br />

(A)<br />

1 Pole + Neutral 3 Pole + Neutral<br />

Catalog Number<br />

Price<br />

Std.<br />

Pkg. Catalog Number<br />

Price<br />

1 L8-1/1N-2/B 62 6 L8-1/3N/B 142 3<br />

2 L8-2/1N-2/B 62 6 L8-2/3N/B 142 3<br />

4 L8-4/1N-2/B 62 6 L8-4/3N/B 142 3<br />

6 L8-6/1N-2/B 62 6 L8-6/3N/B 142 3<br />

8 L8-8/1N-2/B 62 6 L8-8/3N/B 142 3<br />

10 L8-10/1N-2/B 62 6 L8-10/3N/B 142 3<br />

13 L8-13/1N-2/B 62 6 L8-13/3N/B 142 3<br />

16 L8-16/1N-2/B 62 6 L8-16/3N/B 142 3<br />

20 L8-20/1N-2/B 74 6 L8-20/3N/B 166 3<br />

25 L8-25/1N-2/B 74 6 L8-25/3N/B 166 3<br />

32 L8-32/1N-2/B 74 6 L8-32/3N/B 166 3<br />

40 L8-40/1N-2/B 74 6 L8-40/3N/B 166 3<br />

50 L8-50/1N-2/B 94 8 L8-50/3N/B 216 3<br />

63 L8-63/1N-2/B 102 8 L8-63/3N/B 240 3<br />

All Supplementary Protectors + neutral are special order.<br />

Std.<br />

Pkg.<br />

M<br />

<strong>Circuit</strong><br />

Protection<br />

L8<br />

Discount Schedule B-8<br />

M5


L8 Supplementary Protectors<br />

Trip Characteristic C<br />

M<br />

<strong>Circuit</strong><br />

Protection<br />

Trip Characteristic C (5~10 x I N ) – Inductive loads<br />

Rated<br />

Current<br />

(A)<br />

Catalog Number<br />

1 Pole 2 Pole 3 Pole<br />

Price<br />

Std.<br />

Pkg. Catalog Number<br />

Price<br />

Std.<br />

Pkg. Catalog Number<br />

0.5 L8-.5/1/C 42 12 L8-.5/2/C 96 6 L8-.5/3/C 138 4<br />

1 L8-1/1/C 42 12 L8-1/2/C 96 6 L8-1/3/C 138 4<br />

2 L8-2/1/C 42 12 L8-2/2/C 96 6 L8-2/3/C 138 4<br />

3 L8-3/1/C 42 12 L8-3/2/C 96 6 L8-3/3/C 138 4<br />

4 L8-4/1/C 42 12 L8-4/2/C 96 6 L8-4/3/C 138 4<br />

5 L8-5/1/C 42 12 L8-5/2/C 96 6 L8-5/3/C 138 4<br />

6 L8-6/1/C 42 12 L8-6/2/C 96 6 L8-6/3/C 138 4<br />

7 L8-7/1/C 42 12 L8-7/2/C 96 6 L8-7/3/C 138 4<br />

8 L8-8/1/C 42 12 L8-8/2/C 96 6 L8-8/3/C 138 4<br />

10 L8-10/1/C 42 12 L8-10/2/C 96 6 L8-10/3/C 138 4<br />

13 L8-13/1/C 42 12 L8-13/2/C 96 6 L8-13/3/C 138 4<br />

15 L8-15/1/C 42 12 L8-15/2/C 96 6 L8-15/3/C 138 4<br />

16 L8-16/1/C 42 12 L8-16/2/C 96 6 L8-16/3/C 138 4<br />

20 L8-20/1/C 42 12 L8-20/2/C 96 6 L8-20/3/C 138 4<br />

25 L8-25/1/C 46 12 L8-25/2/C 106 6 L8-25/3/C 156 4<br />

30 L8-30/1/C 46 12 L8-30/2/C 106 6 L8-30/3/C 156 4<br />

32 L8-32/1/C 48 12 L8-32/2/C 106 6 L8-32/3/C 158 4<br />

40 L8-40/1/C 52 12 L8-40/2/C 116 6 L8-40/3/C 174 4<br />

50 L8-50/1/C 60 12 L8-50/2/C 136 6 L8-50/3/C 200 4<br />

63 L8-63/1/C 68 12 L8-63/2/C 152 6 L8-63/3/C 228 4<br />

Price<br />

Std.<br />

Pkg.<br />

Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />

L8<br />

M6<br />

Discount Schedule B-8


L8 Supplementary Protectors<br />

Trip Characteristic C<br />

Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />

Trip Characteristic C (5~10 x I N ) – Inductive loads<br />

Rated<br />

Current<br />

(A)<br />

Catalog Number<br />

1 Pole + Neutral 3 Pole + Neutral<br />

Price<br />

Std.<br />

Pkg. Catalog Number<br />

Price<br />

1 L8-1/1N-2/C 84 6 L8-1/3N/C 200 3<br />

2 L8-2/1N-2/C 84 6 L8-2/3N/C 200 3<br />

4 L8-4/1N-2/C 84 6 L8-4/3N/C 200 3<br />

5 L8-5/1N-2/C 84 6 Not Available ~ ~<br />

6 L8-6/1N-2/C 84 6 L8-6/3N/C 200 3<br />

8 L8-8/1N-2/C 84 6 L8-8/3N/C 200 3<br />

10 L8-10/1N-2/C 84 6 L8-10/3N/C 200 3<br />

13 L8-13/1N-2/C 84 6 L8-13/3N/C 200 3<br />

16 L8-16/1N-2/C 84 6 L8-16/3N/C 200 3<br />

20 L8-20/1N-2/C 84 6 L8-20/3N/C 200 3<br />

25 L8-25/1N-2/C 90 6 L8-25/3N/C 210 3<br />

32 L8-32/1N-2/C 92 6 L8-32/3N/C 212 3<br />

40 L8-40/1N-2/C 96 6 L8-40/3N/C 228 3<br />

50 L8-50/1N-2/C 122 8 L8-50/3N/C 276 3<br />

63 L8-63/1N-2/C 130 8 L8-63/3N/C 304 3<br />

All Supplementary Protectors + neutral are special order.<br />

Std.<br />

Pkg.<br />

M<br />

<strong>Circuit</strong><br />

Protection<br />

L8<br />

Discount Schedule B-8<br />

M7


L8 Supplementary Protectors<br />

Trip Characteristic D<br />

M<br />

<strong>Circuit</strong><br />

Protection<br />

Trip Characteristic D (10~20 x I N ) – Highly inductive loads<br />

Rated<br />

Current<br />

(A)<br />

Catalog Number<br />

1 Pole 2 Pole 3 Pole<br />

Price<br />

Std.<br />

Pkg. Catalog Number<br />

Price<br />

Std.<br />

Pkg. Catalog Number<br />

0.5 L8-.5/1/D 42 12 L8-.5/2/D 96 6 Not Available ~ ~<br />

1 L8-1/1/D 42 12 L8-1/2/D 96 6 L8-1/3/D 138 4<br />

2 L8-2/1/D 42 12 L8-2/2/D 96 6 L8-2/3/D 138 4<br />

3 L8-3/1/D 42 12 L8-3/2/D 96 6 L8-3/3/D 138 4<br />

4 L8-4/1/D 42 12 L8-4/2/D 96 6 L8-4/3/D 138 4<br />

5 L8-5/1/D 42 12 L8-5/2/D 96 6 L8-5/3/D 138 4<br />

6 L8-6/1/D 42 12 L8-6/2/D 96 6 L8-6/3/D 138 4<br />

7 L8-7/1/D 42 12 L8-7/2/D 96 6 L8-7/3/D 138 4<br />

8 L8-8/1/D 42 12 L8-8/2/D 96 6 L8-8/3/D 138 4<br />

10 L8-10/1/D 42 12 L8-10/2/D 96 6 L8-10/3/D 138 4<br />

13 L8-13/1/D 42 12 L8-13/2/D 96 6 L8-13/3/D 138 4<br />

15 L8-15/1/D 42 12 L8-15/2/D 96 6 L8-15/3/D 138 4<br />

16 L8-16/1/D 42 12 L8-16/2/D 96 6 L8-16/3/D 138 4<br />

20 L8-20/1/D 42 12 L8-20/2/D 96 6 L8-20/3/D 138 4<br />

25 L8-25/1/D 46 12 L8-25/2/D 106 6 L8-25/3/D 156 4<br />

30 L8-30/1/D 46 12 L8-30/2/D 106 6 L8-30/3/D 156 4<br />

32 L8-32/1/D 48 12 L8-32/2/D 106 6 L8-32/3/D 158 4<br />

40 L8-40/1/D 52 12 L8-40/2/D 116 6 L8-40/3/D 174 4<br />

Price<br />

Std.<br />

Pkg.<br />

Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />

L8<br />

M8<br />

Discount Schedule B-8


L8 Supplementary Protectors<br />

Trip Characteristic D<br />

Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />

Trip Characteristic D (10~20 x I N ) – Highly inductive loads<br />

Rated<br />

Current<br />

(A)<br />

Catalog Number<br />

1 Pole + Neutral 3 Pole + Neutral<br />

Price<br />

Std.<br />

Pkg. Catalog Number<br />

Price<br />

1 L8-1/1N-2/D 84 6 L8-1/3N/D 200 3<br />

2 L8-2/1N-2/D 84 6 L8-2/3N/D 200 3<br />

4 L8-4/1N-2/D 84 6 L8-4/3N/D 200 3<br />

6 L8-6/1N-2/D 84 6 L8-6/3N/D 200 3<br />

8 L8-8/1N-2/D 84 6 L8-8/3N/D 200 3<br />

10 L8-10/1N-2/D 84 6 L8-10/3N/D 200 3<br />

13 L8-13/1N-2/D 84 6 L8-13/3N/D 200 3<br />

16 L8-16/1N-2/D 84 6 L8-16/3N/D 200 3<br />

20 L8-20/1N-2/D 84 6 L8-20/3N/D 200 3<br />

25 L8-25/1N-2/D 90 6 L8-25/3N/D 210 3<br />

32 L8-32/1N-2/D 92 6 L8-32/3N/D 212 3<br />

40 L8-40/1N-2/D 96 6 L8-40/3N/D 228 3<br />

All Supplementary Protectors + neutral are special order.<br />

Std.<br />

Pkg.<br />

M<br />

<strong>Circuit</strong><br />

Protection<br />

L8<br />

Discount Schedule B-8<br />

M9


Accessories<br />

Series L8 Supplementary Protectors<br />

Accessories<br />

M<br />

<strong>Circuit</strong><br />

Protection<br />

Module<br />

Description<br />

Selectable Two Pole Auxiliary Contact or<br />

Auxiliary / Signal Alarm Module –<br />

• Small set-screw alternates between<br />

operational modes<br />

• Two Form C (two changeover contacts)<br />

• Installs on left side of L8<br />

• Auxiliary contact switches when L8 is<br />

operated manually or tripped electrically<br />

• Signal Alarm contact switches only when<br />

L8 is tripped electrically<br />

Shunt Trip –<br />

• Remotely trips the device<br />

• Installs on left side of L8<br />

Undervoltage Release –<br />

• Prevents device from operating unless<br />

voltage is present<br />

• Installs on left side of L8<br />

• Test button<br />

For use<br />

with…<br />

All L8s<br />

& Shunt<br />

Trip<br />

All L8s<br />

12…110VAC<br />

110…415VAC<br />

All L8s<br />

115 VAC<br />

230 VAC<br />

Connection<br />

Diagrams Catalog Number Price<br />

Two pole auxiliary mode<br />

Auxiliary / Signal alarm mode<br />

LX-AHS3 71<br />

Z8-ASA24<br />

Z8-ASA230<br />

Z8-USA115<br />

Z8-USA230<br />

Allowable Combinations of Field Installed Modules<br />

(1) Auxiliary Contact Module<br />

(1) Selectable Two Pole Auxiliary Contact Module / Auxiliary & Signal Alarm<br />

Contact Module<br />

(1) Shunt Trip Module<br />

(1) Undervoltage Release Module<br />

(1) Auxiliary Contact Module + (1) Shunt Trip Module<br />

All modules install on the left side of the L8.<br />

186<br />

186<br />

292<br />

Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />

L8<br />

M10<br />

Discount Schedule B-8


Accessories<br />

Series L8 Supplementary Protectors<br />

Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />

Accessories<br />

Accessory Description For use with… Catalog Number Price<br />

Bus Bar – ➊<br />

• Connects one, two and three pole L8s<br />

• Connects one pole + neutral and three<br />

pole + neutral MCBs<br />

• Rated to 80A<br />

• Available in 1 meter lengths<br />

• IEC rated only<br />

End Caps – ➋<br />

• Covers end of Bus Bar to provide touch<br />

safe protection (minimum order quantity<br />

10)<br />

Padlock Hasp –<br />

• Fits securely over switch handle. Prevents<br />

unauthorized activation of L8 during<br />

maintenance<br />

• Provision for one padlock<br />

DIN-rail - 2 meter lengths (6' 6")<br />

All L8 one pole devices<br />

All L8 two pole devices &<br />

one pole + neutral<br />

All L8 three pole devices<br />

All L8 three pole +<br />

neutral devices<br />

Fits ZV7-16-1P+N-2TE &<br />

ZV7-16-3P-3TE<br />

Fits ZV7-16-3P+N-4TE<br />

ZV7-16-1P-1TE<br />

ZV7-16-1P+N-2TE<br />

ZV7-16-3P-3TE<br />

ZV7-16-3P+N-4TE<br />

ZV7-16-AK/2+3P<br />

ZV7-16-AK/4P<br />

51<br />

140<br />

176<br />

238<br />

All L8 MCBs HA7-SPE 12<br />

Top Hat, low profile (price per rail) 3F 28.50<br />

Top Hat, high profile (price per rail) 3AF 43.75<br />

➊ Each bus bar accommodates:<br />

1 pole bus connects 57 devices<br />

2 pole bus connects 28 devices<br />

3 pole bus connects 19 devices<br />

Total current must not exceed 80A per bus.<br />

➋ Sold in packages of 10. Price indicated is price per piece.<br />

Minimum order quantity 10.<br />

3<br />

3<br />

M<br />

<strong>Circuit</strong><br />

Protection<br />

L8<br />

Discount Schedule B-8<br />

M11


Technical Data<br />

Series L8 Supplementary Protectors<br />

M<br />

<strong>Circuit</strong><br />

Protection<br />

L8<br />

Technical Data<br />

General Data B Curve C Curve D Curve<br />

Resistive or slightly resistive Inductive Loads Highly Inductive Loads<br />

Tripping Characteristic I n 3…5 x I n 5…10 x I n 10…20 x I n<br />

Approvals UR, CSA, VDE, CE UR, CSA, VDE, CE UR, VDE, CE<br />

Maximum Voltage Ratings<br />

UL/CSA<br />

IEC<br />

(All models ) IEC-EN 60 898 / VDE 0641 / DIN 43 880<br />

1-pole [V] 277VAC; 48VDC 277VAC; 48VDC 277VAC; 48VDC<br />

1-pole + neutral [V] 277VAC 277VAC 277VAC<br />

2-pole [V] 480Y/277VAC; 125VDC 480Y/277VAC; 125VDC 480Y/277VAC; 125VDC<br />

3-pole [V] 480Y/277VAC 480Y/277VAC 480Y/277VAC<br />

3-pole + neutral [V] 480Y/277VAC 480Y/277VAC 480Y/277VAC<br />

1-pole [V] 240/415VAC 240/415VAC 240/415VAC<br />

1-pole + neutral [V] 240VAC 240VAC 240VAC<br />

2-pole [V] 415VAC 415VAC 415VAC<br />

3-pole [V] 415VAC 415VAC 415VAC<br />

3-pole + neutral [V] 415VAC 415VAC 415VAC<br />

Supplementary Protector<br />

Approvals UL 1077, CSA 22.2 No. 235<br />

Current Range [A] 1…63 0.5…63 0.5…40<br />

Thermal Tripping Characteristic 1.55 x I n @ 30°C Cu 75°C<br />

Withstand Rating, 1-pole without Series Fuse [kA] 5 @ 277VAC U1<br />

Withstand Rating, Multi-pole with Series Fuse [kA] 5 @ 480Y / 277VAC C1<br />

Withstand Rating, All poles without Series Fuse [kA] 1 pole 10 @ 48VDC U1; 2 pole in series 10 @ 125VDC U1<br />

Miniature <strong>Circuit</strong> Breaker<br />

Approvals<br />

IEC / EN 60 898 (VDE) IEC / EN 60 947-2 (GL)<br />

Current Range [A] 1…63 0.5…63 0.5…40<br />

Thermal Tripping Characteristic<br />

>1 hr. at 1.13 x I n<br />


Technical Data<br />

Series L8 Supplementary Protectors<br />

Technical Data (continued)<br />

Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />

<strong>Circuit</strong> Diagrams<br />

1 pole 1 pole + neutral 2 pole 3 pole 3 pole + neutral<br />

Back up Protection<br />

Supplementary Protectors / Fuses: The following table shows the maximum short<br />

circuit current when fuses meeting the requirements of IEC 60269-1 are used as<br />

backup protection to MCBs.<br />

Miniature <strong>Circuit</strong><br />

Breaker<br />

Characteristic B<br />

Characteristic C<br />

Mechanical Data<br />

Degree of Protection<br />

Rated<br />

Current (I n )<br />

Upstream Fuse<br />

100A 160A 200A<br />

1…10A 40kA 25kA 25kA<br />

10…50A 50kA 40kA 25kA<br />

63A 50kA 40kA 10kA<br />

Mechanical endurance [ops.] 6,000 (1 operation = 2 switching movements – ON/OFF<br />

Method of mounting<br />

Supply connection<br />

Terminations<br />

Terminal type<br />

Wire size<br />

360˚<br />

360˚<br />

IP20<br />

35mm mounting rail (EN50022<br />

Line or load side<br />

solid / stranded [mm 2 ] / (AWG) 1.0…2.5 (18…8<br />

Recommended Wire Strip Length [mm] / (in.) 13 / 0.5<br />

Tightening torque [Nm] / [lb-in] 2.4 / 21.2<br />

Weight / pole [g] / [lb] 120 / 0.32<br />

Mounting Position<br />

M<br />

<strong>Circuit</strong><br />

Protection<br />

L8<br />

Discount Schedule B-8<br />

M13


Technical Data<br />

Series L8 Supplementary Protectors<br />

M<br />

<strong>Circuit</strong><br />

Protection<br />

L8<br />

Technical Data (continued)<br />

Continuous Current Rating Factor<br />

Accessories<br />

➊ When using two wires, use same cross section.<br />

Rated Diversity Factor<br />

When multiple supplementary protectors are mounted side by side, they must be<br />

derated to determine the load carrying capacity.<br />

Auxiliaries Undervoltage Release Shunt Trip<br />

Z8-AHK, NHK Z8-USA… Z8-ASA…<br />

Degree of protection (Field Wiring Terminals) IP20 (IP 00) IP20 (IP 00) IP20 (IP 00)<br />

Minimum Impulse Duration [ms] ~ ~ >15<br />

Minimum Command Time [ms] ~ ~ ≤200<br />

Operating Voltage [V] ~ U n - 115V (Z7-USA115) 12…110VAC (Z7-ASA24)<br />

U min - 50V<br />

12…60VDC<br />

~ U n - 230/240 (Z7-USA230) 110…415VAC (Z7-ASA230)<br />

U min - 110V<br />

110…230VDC<br />

Inrush Current [mA] ~ 3.6 / 44 (AC/DC) 25 / 12 (AC<br />

Dropout ~ 0.7…0.35 x U s ~<br />

15 / 2 (DC)<br />

Voltage Range [V] ~ ~ 0.7…1.1 x U s<br />

Max. operational current I e ~ ~<br />

AC13 250V [A] 3 ~ ~<br />

IEC AC15 250V [A] 2 ~ ~<br />

DC12 110V [A] 0.5 ~ ~<br />

UL1077 / AC 230V [A] 2 ~ ~<br />

CSA22.2 DC 110V [A] 0.5 ~ ~<br />

Auxiliaries Undervoltage Release Shunt Trip<br />

Z8-AHK, NHK Z8-USA… Z8-ASA…<br />

Mechanical Life-span [ops] 6000 10000 4000<br />

Terminations ➊<br />

Terminal type<br />

Wire size<br />

solid / stranded<br />

1 conductor<br />

2 conductors<br />

0.5…2.5 (18…14)<br />

0.5…2.5 (18…14)<br />

0.5…4 (18…14)<br />

0.5…2.5 (18…14)<br />

1.0…25 (18…8)<br />

1.0…4 (18…12)<br />

Tightening torque [Nm] / [lb-in] 0.8 / 7 1.1 / 10 2.4 / 21<br />

Weight [g] / [lbs] 45 / 0.1 155 / 0.4 155 / 0.4<br />

Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />

M14<br />

Discount Schedule B-8


Dimensions<br />

Series L8 Supplementary Protectors<br />

Technical Data (continued)<br />

Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />

Let-through energy I 2 t [A 2 sec]<br />

Let-through energy I 2 t [A 2 sec]<br />

80000<br />

70000<br />

60000<br />

50000<br />

40000<br />

30000<br />

20000<br />

15000<br />

10000<br />

9000<br />

8000<br />

7000<br />

6000<br />

5000<br />

4000<br />

3000<br />

2000<br />

1500<br />

1000<br />

900<br />

800<br />

700<br />

600<br />

500<br />

400<br />

300<br />

80000<br />

70000<br />

60000<br />

50000<br />

40000<br />

30000<br />

20000<br />

15000<br />

10000<br />

9000<br />

8000<br />

7000<br />

6000<br />

5000<br />

4000<br />

3000<br />

2000<br />

1500<br />

1000<br />

900<br />

800<br />

700<br />

600<br />

500<br />

400<br />

300<br />

500<br />

1000<br />

Maximum let-through energy L8<br />

Type B<br />

1500<br />

2000<br />

3000<br />

4000<br />

5000<br />

Available short-circuit current [A]<br />

Maximum let-through energy L8<br />

Type C<br />

6000<br />

7000<br />

8000<br />

9000<br />

10000<br />

15000<br />

B63<br />

B50<br />

B40<br />

B13 B16<br />

B20<br />

B25 B32<br />

B10<br />

B6<br />

B4<br />

B2<br />

C63<br />

C50<br />

C32<br />

C25 C40<br />

C16<br />

C20<br />

C13<br />

C10<br />

C6<br />

C4<br />

C3.5<br />

C3<br />

C2<br />

C2.5<br />

C1.5<br />

C1<br />

C0.5<br />

Let-through current [A]<br />

Let-through current [A]<br />

10000<br />

9000<br />

8000<br />

7000<br />

6000<br />

5000<br />

4000<br />

3000<br />

2000<br />

1500<br />

1000<br />

500<br />

10000<br />

9000<br />

8000<br />

7000<br />

6000<br />

5000<br />

4000<br />

3000<br />

2000<br />

1500<br />

1000<br />

500<br />

500<br />

Maximum let-through current L8<br />

Type B<br />

1000<br />

1500<br />

2000<br />

3000<br />

4000<br />

6000<br />

Available short circuit current [A]<br />

Maximum let-through current L8<br />

Type C<br />

7000<br />

8000<br />

9000<br />

10000<br />

15000<br />

B20B25B32B40B50B63<br />

B13<br />

B16<br />

B10<br />

B4 B6<br />

B2<br />

C63<br />

C50<br />

C40<br />

C32<br />

C25<br />

C20<br />

C16<br />

C13<br />

C10<br />

C4 C6<br />

C3 C3.5<br />

C2.5<br />

C2<br />

C1.5<br />

C1<br />

M<br />

<strong>Circuit</strong><br />

Protection<br />

500<br />

1000<br />

1500<br />

2000<br />

3000<br />

4000<br />

5000<br />

Available short-circuit current [A]<br />

6000<br />

7000<br />

8000<br />

9000<br />

10000<br />

15000<br />

500<br />

1000<br />

1500<br />

2000<br />

3000<br />

4000<br />

6000<br />

Available short circuit current [A]<br />

7000<br />

8000<br />

9000<br />

10000<br />

15000<br />

L8<br />

Discount Schedule B-8<br />

M15


Technical Data<br />

Series L8 Supplementary Protectors<br />

Technical Data (continued)<br />

M<br />

<strong>Circuit</strong><br />

Protection<br />

Let-through energy I 2 t [A 2 sec]<br />

80000<br />

70000<br />

60000<br />

50000<br />

40000<br />

30000<br />

20000<br />

15000<br />

10000<br />

9000<br />

8000<br />

7000<br />

6000<br />

5000<br />

4000<br />

3000<br />

2000<br />

1500<br />

1000<br />

900<br />

800<br />

700<br />

600<br />

500<br />

400<br />

300<br />

500<br />

1000<br />

Maximum let-through energy L8<br />

Type D<br />

1500<br />

2000<br />

3000<br />

4000<br />

5000<br />

Available short-circuit current [A]<br />

6000<br />

7000<br />

8000<br />

9000<br />

10000<br />

15000<br />

D6<br />

D40<br />

D32<br />

D20<br />

D16<br />

D25<br />

D13<br />

D10<br />

D4<br />

D2<br />

Let-through current [A]<br />

10000<br />

9000<br />

8000<br />

7000<br />

6000<br />

5000<br />

4000<br />

3000<br />

2000<br />

1500<br />

1000<br />

500<br />

500<br />

Maximum let-through current L8<br />

Type D<br />

1000<br />

1500<br />

2000<br />

3000<br />

4000<br />

6000<br />

Available short circuit current [A]<br />

7000<br />

8000<br />

9000<br />

10000<br />

15000<br />

D40<br />

D32<br />

D25<br />

D20<br />

D16<br />

D13<br />

D10<br />

D6<br />

D4<br />

D2<br />

Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />

L8<br />

M16<br />

Discount Schedule B-8


Dimensions<br />

Series L8 Supplementary Protectors<br />

Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />

• Dimensions are in millimeters<br />

• Dimensions not intended for manufacturing purposes<br />

• Dimensions are in millimeters<br />

• Dimensions not intended for manufacturing purposes<br />

• Dimensions are in millimeters<br />

• Dimensions not intended for manufacturing purposes<br />

L8 Supplementary Protectors (Series L8…B, C & D)<br />

1-pole 2-pole and 3-pole 3-pole + neutral<br />

1-pole + neutral<br />

One & Two Pole Auxiliary Contact, Signal Alarm Contact (LX-AHS3)<br />

Shunt Trip & Undervoltage Release Modules (Z8-ASA…& Z8-USA…)<br />

Shunt Trip<br />

Undervoltage Release Module<br />

M<br />

<strong>Circuit</strong><br />

Protection<br />

L8<br />

Discount Schedule B-8<br />

M17


M<br />

Series L9<br />

UL-489 Miniature<br />

<strong>Circuit</strong> Breakers<br />

Industrial <strong>Circuit</strong><br />

Breakers for Branch<br />

<strong>Circuit</strong> Protection<br />

up to 40 Amps<br />

Sprecher+Schuh includes a new line of<br />

circuit breakers approved for branch<br />

circuit applications in the United<br />

States and Canada and certified as a<br />

Miniature <strong>Circuit</strong> Breaker for IEC<br />

applications. The Sprecher + Schuh<br />

Breakers are UL489 listed and CSA<br />

22.2 No. 5.1 to provide branch <strong>Circuit</strong><br />

Breakers to IEC 60 947-2.<br />

Broad product range &<br />

flexibility<br />

The Sprecher + Schuh L9 Miniature<br />

<strong>Circuit</strong> Breakers provide a variety<br />

of product configurations by offering<br />

current ranges of 0.5A to 40A<br />

with voltage ranges of 240V AC and<br />

480Y/277V AC. The Series L9 DIN<br />

Rail-mounted circuit breakers are<br />

similar in width and current range to<br />

circuit breakers with the added benefit<br />

of providing listed branch circuit protection<br />

circuit breaker for US/Canada<br />

applications.<br />

Also available for control circuit applications<br />

are add-on auxiliary and<br />

signal contacts plus shunt trip modules<br />

to provide modern control circuit<br />

applications. A lock-off attachment is<br />

available for applications requiring that<br />

feature.<br />

Safety features provide<br />

enhanced protection<br />

The series L9 Miniature <strong>Circuit</strong> Breakers<br />

feature finger-safe IPX/2 from the<br />

front of the circuit breaker to guard<br />

against accidental contact with live<br />

parts.<br />

To aid troubleshooting, a color-coded<br />

indicator provides positive visual indication<br />

of the device status (green for OFF,<br />

red for ON and isolation function).<br />

The Series L9 also incorporate a trip<br />

free mechanism - ensuring that the<br />

device operation cannot be defeated<br />

by holding the operator in the ON<br />

position.<br />

Easy installation<br />

The Series L9 Miniature <strong>Circuit</strong> Breakers<br />

mount on a standard 35mm DINrail.<br />

Wire terminals accept multiple<br />

conductors. In addition, power to the<br />

circuit breakers can be fed from the<br />

line or load side.<br />

Global approvals for<br />

worldwide acceptance<br />

The Sprecher + Schuh L9 <strong>Circuit</strong><br />

Breakers are UL489 listed, CSA 22.2<br />

No. 5.1 approved and meets IEC<br />

60 947-2. The Series L9 also have<br />

an HACR rating (heating and air<br />

conditioning) as well as a "Switching<br />

Duty" (SWD) rating from 0.5 to 20A.<br />

Switching Duty ratings are related to<br />

fluorescent light applications only, not<br />

High intensity discharge (HID) lights<br />

or any other types of loads. Advanced<br />

features and global approvals make<br />

the Series L9 an ideal product for<br />

use in industrial equipment installed<br />

throughout the world.<br />

Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />

<strong>Circuit</strong><br />

Protection<br />

L9<br />

M18<br />

17.5mm 35mm 52.5mm<br />

(≈11/16˝) (≈1-3/8˝) (≈2-1/8˝)<br />

One Pole Two Pole Three Pole


L9 UL489 Miniature <strong>Circuit</strong> Breakers<br />

Series L9<br />

Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />

Product Design &<br />

Application<br />

The Series L9 products are thermalmagnetic<br />

(inverse time) circuit breakers<br />

offering the benefits of a modern<br />

circuit breaker design in a compact<br />

size. The L9 is used mainly in control<br />

circuit applications where branch<br />

circuit approved circuit breakers are<br />

required.<br />

Because of its range of protection<br />

(from 0.5 to 40A) many customers<br />

may use this product for protection<br />

of load devices where fuses or<br />

other supplementary protector devices<br />

previously were used in the U.S. and<br />

Canada.<br />

Protection of PLC I/O, solenoids,<br />

power supplies and control transformers<br />

along with providing the listed<br />

branch circuit protection is available in<br />

one device.<br />

Box lug terminals accept<br />

#18…#6 AWG wire as<br />

standard<br />

Current limiting and<br />

interrupting capacity up to<br />

10kA at 480Y/277V AC.<br />

Trip-free mechanism;<br />

device operation cannot<br />

be defeated by holding the<br />

operator in the ON position<br />

Color coded indicator<br />

provides visual indication<br />

of the device status and<br />

isolation function<br />

Available in one, two and<br />

three pole;<br />

Description<br />

L9 <strong>Circuit</strong> Breakers for Branch <strong>Circuit</strong><br />

protection are available one (1)-, two<br />

(2-), and three (3-) pole construction<br />

and are rated 0.5 to 40A at 240VC AC<br />

and 0.5 to 20A at 480Y/277V AC for<br />

North American applications (UL 489<br />

and CSA 22.2 No. 5.1). For IEC applications,<br />

the products are rated 415V<br />

AC 0.5 to 40A.<br />

Continuous Current Rating<br />

Standard current ratings are: 0.5A, 1A,<br />

1.5A, 2A, 3A, 4A, 5A, 6A, 7A, 8A,<br />

10A, 15A, 16A, 20A, 25A, 30A, 32A,<br />

35A and 40A.<br />

The L9 circuit breakers are rated in<br />

RMS amperes at 40°C (104°F) ambient<br />

temperature per the UL 489 (XSA<br />

22.2 No. 5.1) standard. This temperature<br />

is generally used as the average<br />

temperature within an industrial<br />

enclosure. If a circuit breaker is applied<br />

in a temperature that exceeds 40°C<br />

(104°F) ambient, then the circuit<br />

Compare these advanced features<br />

Line and load side terminals<br />

accept bus bar connections<br />

for reduced costs and more<br />

efficient installation of<br />

multiple devices.<br />

Guarded posidrive terminal<br />

screws with finger-safe<br />

protection to IEC 947-1<br />

Devices install on standard<br />

35mm DIN-rail (EN 50022)<br />

Magnetic trip elements<br />

provide Type C and D trip<br />

characteristics (IEC and EN<br />

60898), while bimetallic<br />

elements protect against<br />

slight overloads.<br />

Amp rating and trip curve<br />

characteristic clearly marked<br />

on the device for easy<br />

identification.<br />

breaker should be derated. For IEC 60<br />

947-2 standard, the products carry an<br />

ambient rating of 30 C. Follow standard<br />

IEC application considerations<br />

for temperature rating in different<br />

ambient temperatures.<br />

The characteristic trip curves are<br />

shown on page M29. The trip bands<br />

shown for each breaker represent<br />

current tripping limits for a circuit<br />

breaker and are within the limits established<br />

by UL. For a specific current<br />

at 40°C (104°F), a circuit breaker will<br />

open ("clear the circuit") automatically<br />

at some total time that will be within<br />

the "Minimum" and "Maximum"<br />

time shown on the curves.<br />

Example: The L9 time-current graph<br />

on page M29 shows that a one-pole,<br />

15 A, L9 circuit breaker trips in not<br />

less than 10 sec, and not more than<br />

120 sec. on a 30 A current. Because<br />

the UL standard defines this time<br />

spread, users should not specify exact<br />

tripping time. The lower current portion<br />

of the curves (upper left) depict<br />

the time to trip due to thermal action<br />

and reflect overload protection of the<br />

wire and connect load. The higher<br />

current portion of the curves (lower<br />

right) depicts the trip due to the magnetic<br />

action of the circuit breaker and<br />

reflects protection due to short circuit<br />

level currents.<br />

M<br />

<strong>Circuit</strong><br />

Protection<br />

L9<br />

M19


L9 UL489 Miniature <strong>Circuit</strong> Breakers<br />

Trip Characteristic C<br />

M<br />

<strong>Circuit</strong><br />

Protection<br />

Trip Characteristic C (5~10 x I N ) – Inductive loads<br />

➊<br />

UL/CSA<br />

Max.<br />

Volt.<br />

480Y/277<br />

240<br />

Rated<br />

Current<br />

(A)<br />

Catalog Number<br />

1 Pole 2 Pole 3 Pole<br />

Price<br />

Std.<br />

Pkg. Catalog Number Price<br />

Std.<br />

Pkg. Catalog Number Price<br />

0.5 L9-.5/1/C 97 2 L9-.5/2/C 185 1 L9-.5/3/C 251 1<br />

1 L9-1/1/C 97 2 L9-1/2/C 185 1 L9-1/3/C 251 1<br />

1.5 L9-1.5/1/C 97 2 L9-1.5/2/C 185 1 L9-1.5/3/C 251 1<br />

2 L9-2/1/C 97 2 L9-2/2/C 185 1 L9-2/3/C 251 1<br />

3 L9-3/1/C 97 2 L9-3/2/C 185 1 L9-3/3/C 251 1<br />

4 L9-4/1/C 97 2 L9-4/2/C 185 1 L9-4/3/C 251 1<br />

5 L9-5/1/C 97 2 L9-5/2/C 185 1 L9-5/3/C 251 1<br />

6 L9-6/1/C 97 2 L9-6/2/C 185 1 L9-6/3/C 251 1<br />

7 L9-7/1/C 97 2 L9-7/2/C 185 1 L9-7/3/C 251 1<br />

8 L9-8/1/C 97 2 L9-8/2/C 185 1 L9-8/3/C 251 1<br />

10 L9-10/1/C 97 2 L9-10/2/C 185 1 L9-10/3/C 251 1<br />

13 L9-13/1/C 97 2 L9-13/2/C 185 1 L9-13/3/C 251 1<br />

15 L9-15/1/C 97 2 L9-15/2/C 185 1 L9-15/3/C 251 1<br />

16 L9-16/1/C 97 2 L9-16/2/C 185 1 L9-16/3/C 251 1<br />

20 L9-20/1/C 97 2 L9-20/2/C 185 1 L9-20/3/C 251 1<br />

25 L9-25/1/C 107 2 L9-25/2/C 198 1 L9-25/3/C 251 1<br />

30 L9-30/1/C 110 2 L9-30/2/C 211 1 L9-30/3/C 279 1<br />

32 L9-32/1/C 110 2 L9-32/2/C 211 1 L9-32/3/C 279 1<br />

35 L9-35/1/C 110 2 L9-35/2/C 211 1 L9-35/3/C 279 1<br />

40 L9-40/1/C 115 2 L9-40/2/C 227 1 L9-40/3/C 292 1<br />

L9 Miniature <strong>Circuit</strong> Breaker Features:<br />

• UL-489 listed for Branch <strong>Circuit</strong> protection and CSSA 22.2 No. 5.1 Approved<br />

• Thermal magnetic protection<br />

• Trip characterisitc based on 40°C ambient for UL/CSA<br />

• 10kA interrupting rating<br />

• All ratings are HACR rated (SWD rated up to 20 A)<br />

• Finger safe design (front)<br />

• DIN rail mounting<br />

Std.<br />

Pkg.<br />

Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />

L9<br />

➊ Rated 415V AC IEC max/min meets IEC 60947-2 for miniature circuit breakers.<br />

M20 Discount Schedule B-8


L9 UL489 Miniature <strong>Circuit</strong> Breakers<br />

Trip Characteristic D<br />

Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />

Trip Characteristic D (10~20 x I N ) – Highly inductive loads<br />

➊<br />

UL/CSA<br />

Max.<br />

Volt.<br />

480Y/277<br />

240<br />

Rated<br />

Current<br />

(A)<br />

Catalog Number<br />

1 Pole 2 Pole 3 Pole<br />

Price<br />

Std.<br />

Pkg. Catalog Number Price<br />

Std.<br />

Pkg. Catalog Number Price<br />

0.5 L9-.5/1/D 97 2 L9-.5/2/D 186 1 L9-1,5/3/D 256 1<br />

1 L9-1/1/D 97 2 L9-1/2/D 186 1 L9-1/3/D 256 1<br />

1.5 L9-1.5/1/D 97 2 L9-1.5/2/D 186 1 L9-1.5/3/D 256 1<br />

2 L9-2/1/D 97 2 L9-2/2/D 186 1 L9-2/3/D 256 1<br />

3 L9-3/1/D 97 2 L9-3/2/D 186 1 L9-3/3/D 256 1<br />

4 L9-4/1/D 97 2 L9-4/2/D 186 1 L9-4/3/D 256 1<br />

5 L9-5/1/D 97 2 L9-5/2/D 186 1 L9-5/3/D 256 1<br />

6 L9-6/1/D 97 2 L9-6/2/D 186 1 L9-6/3/D 256 1<br />

7 L9-7/1/D 97 2 L9-7/2/D 186 1 L9-7/3/D 256 1<br />

8 L9-8/1/D 97 2 L9-8/2/D 186 1 L9-8/3/D 256 1<br />

10 L9-10/1/D 97 2 L9-10/2/D 186 1 L9-10/3/D 256 1<br />

13 L9-13/1/D 97 2 L9-13/2/D 186 1 L9-13/3/D 256 1<br />

15 L9-15/1/D 97 2 L9-15/2/D 186 1 L9-15/3/D 256 1<br />

16 L9-16/1/D 97 2 L9-16/2/D 186 1 L9-16/3/D 256 1<br />

20 L9-20/1/D 97 2 L9-20/2/D 186 1 L9-20/3/D 256 1<br />

25 L9-25/1/D 107 2 L9-25/2/D 199 1 L9-25/3/D 285 1<br />

30 L9-30/1/D 110 2 L9-30/2/D 199 1 L9-30/3/D 285 1<br />

32 L9-32/1/D 110 2 L9-32/2/D 199 1 L9-32/3/D 285 1<br />

35 L9-35/1/D 115 2 L9-35/2/D 199 1 L9-35/3/D 285 1<br />

40 L9-40/1/D 115 2 L9-40/2/D 212 1 L9-40/3/D 310 1<br />

L9 Miniature <strong>Circuit</strong> Breaker Features:<br />

• UL-489 listed for Branch <strong>Circuit</strong> protection and CSSA 22.2 No. 5.1 Approved<br />

• Thermal magnetic protection<br />

• Trip characterisitc based on 40°C ambient for UL/CSA<br />

• 10kA interrupting rating<br />

• All ratings are HACR rated (SWD rated up to 20 A)<br />

• Finger safe design (front)<br />

• DIN rail mounting<br />

Std.<br />

Pkg.<br />

M<br />

<strong>Circuit</strong><br />

Protection<br />

➊ Rated 415V AC IEC max/min meets IEC 60947-2 for miniature circuit breakers.<br />

L9<br />

Discount Schedule B-8<br />

M21


Accessories<br />

Series L9 UL489 Miniature <strong>Circuit</strong> Breakers<br />

M<br />

<strong>Circuit</strong><br />

Protection<br />

L9<br />

Accessories<br />

Module<br />

Auxiliary<br />

LX-AHS3<br />

X<br />

X<br />

+<br />

Shunt<br />

L9-<strong>AA</strong>ST...<br />

X<br />

X<br />

Description<br />

Selectable Two Pole Auxiliary Contact or<br />

Auxiliary / Signal Alarm Module –<br />

• Small set-screw alternates between<br />

operational modes<br />

• Two Form C (two changeover contacts)<br />

• Installs on left side of L9<br />

• Auxiliary contact switches when L9 is<br />

operated manually or tripped electrically<br />

• Signal Alarm contact switches only when<br />

L9 is tripped electrically<br />

Shunt Trip –<br />

• Remotely trips the device<br />

• Installs on left side of L9<br />

Padlock Hasp –<br />

• Fits securely over switch handle. Prevents<br />

unauthorized activation of L9 during<br />

maintenance<br />

DIN-rail - 2 meter lengths (6' 6")<br />

For use<br />

with…<br />

All L9s<br />

& Shunt<br />

Trip<br />

All L9s<br />

110…415VAC<br />

12…110VAC<br />

Connection<br />

Diagrams Catalog Number Price<br />

Two pole auxiliary mode<br />

Auxiliary / Signal alarm mode<br />

LX-AHS3 71<br />

L9-ASTA1<br />

L9-ASTA2<br />

All L9s L9-<strong>AA</strong>LOA 20<br />

Top Hat, low profile (price per rail) 3F 28.50<br />

Top Hat, high profile (price per rail) 3AF 43.75<br />

L9-...<br />

Allowable Combinations of Accessories per Supplementary Protectors →<br />

(read left to right)<br />

X<br />

X<br />

X<br />

Allowable Combinations of Field Installed Modules<br />

(1) Selectable Two Pole Auxiliary Contact Module / Auxiliary & Signal Alarm<br />

Contact Module<br />

(1) Shunt Trip Module<br />

(1) Auxiliary Contact Module + (1) Shunt Trip Module<br />

All modules install on the left side of the Supplementary Protectors.<br />

76<br />

Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />

M22 Discount Schedule B-8


Technical Data<br />

Series L9 UL489 Miniature <strong>Circuit</strong> Breakers<br />

Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />

Technical Data<br />

General Data<br />

Number of Poles 1, 2 and 3<br />

Standards UL 489<br />

Certifications<br />

CSA 22.2 No. 5.1<br />

IEC 60 947-2<br />

UL Listed <strong>Circuit</strong> Breaker<br />

CSA Certified, CE<br />

HACR Rating (USA/Canada)<br />

Yes<br />

SWD Rating (USA/Canada) Yes (0.5...20 A)<br />

Calibration Temperature 40°C<br />

Rated Interrupting Capacity<br />

Rated Tripping Current<br />

Degree of Protection<br />

Normal Operating Environment<br />

Trip Curves<br />

Shipment and Short-Term Storage Limits<br />

Wire Size<br />

Terminal Torque<br />

Recommended Wire Strip Length<br />

Auxillaries<br />

Auxiliary Contact,<br />

2 sets, each are Form C,<br />

1 NO & 1 NC<br />

LX-AHS3<br />

UL/CSA: 10 000 AIC<br />

IEC - lcu: 10 000 A<br />

UL/CSA: 0.5...20 A, 480Y/277V AC<br />

0.5...40 A, 240V AC<br />

IEC: 0.5...40 A, 415V AC<br />

Finger-safe from front:<br />

-IP20 per IEC 529 from front<br />

-IP00 at wire terminals<br />

-25...55°C (23...104°F) (non-condensing)<br />

C curve (inductive) 5...10 IN<br />

D curve (Highly inductive) 10...20 IN<br />

-40..85°C (-40...185°F)<br />

1 wire: #18...6 AWG<br />

2 wire: #18...10 AWG<br />

#18...12 AWG: 21 lb-in<br />

#10...8 AWG: 25 lb-in<br />

#6 AWG: 36 lb-in<br />

0.5 in<br />

Shunt Trip Module<br />

L9-ASTA1<br />

Shunt Trip Module<br />

L9-ASTA2<br />

CSA/UL Certifications Yes Yes Yes<br />

IEC 60 947-2 Compliance Yes Yes Yes<br />

CE Yes Yes Yes<br />

IEC Max. Voltage 250V AC 110...415V AC 12...110V AC<br />

UL/CSA Max. Voltage 240V AC ➊ 110...415V AC 12...110V AC<br />

Connection Cable Cable Cable<br />

Mechanical Life-span<br />

Aux...LX-AHS3<br />

Shunt Trip L9-<strong>AA</strong>STA...<br />

Terminations [ops) 6000 4000<br />

Terminal type<br />

Wire size<br />

1 conductor 0.5...2.5 (18...14) 1.0...6 (18...10)<br />

solid /stranded 2 conductors 0.5...2.5 (18...14) 1.0...6 (18...10)<br />

Tightening torque [Nm] / [lb-in] 0.8 / 7 2.8 / 25<br />

Weight [g] / [lbs] 45 / 0.1 155 / 0.4<br />

M<br />

<strong>Circuit</strong><br />

Protection<br />

➊ Use of auxiliary or signal contact limits the circuit breaker to a maximum voltage of 240V AC for UL/CSA applications.<br />

L9<br />

Discount Schedule B-8<br />

M23


Dimensions<br />

Series L9 UL489 Miniature <strong>Circuit</strong> Breakers<br />

M<br />

<strong>Circuit</strong><br />

Protection<br />

L9<br />

• Dimensions are in millimeters<br />

• Dimensions not intended for manufacturing purposes<br />

1 pole 2 pole 3 pole<br />

• Dimensions are in millimeters<br />

• Dimensions not intended for manufacturing purposes<br />

• Dimensions are in millimeters<br />

• Dimensions not intended for manufacturing purposes<br />

L9 Miniature <strong>Circuit</strong> Breakers (Series L9…C & D)<br />

Two Pole Auxiliary Contact, Signal Alarm Contact (LX-AHS3)<br />

Shunt Trip (L9-<strong>AA</strong>STA...)<br />

Shunt Trip<br />

Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />

M24 Discount Schedule B-8


Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />

Methods of Applying<br />

<strong>Circuit</strong> Protection<br />

This information is provided to aid in proper system design and utilization<br />

of circuit protection devices in North American applications.<br />

Be sure to consider all applicable local and national codes for your<br />

particular installation.<br />

M<br />

<strong>Circuit</strong><br />

Protection<br />

M25


<strong>Circuit</strong> Protection Methods<br />

Series L8 Supplementary Protectors<br />

Applying L8 Supplementary Protectors in accordance with UL & NEC Guidelines (continued)<br />

M<br />

<strong>Circuit</strong><br />

Protection<br />

Secondary Supplementary Protectors Selection<br />

• 50VA/120V = 0.42A rated transformer secondary current<br />

• 0.42A is less than 9, therefore may increase up to 167%<br />

• 0.42A x 167% =0.70A, Select L8-1/1/D or L8-1/1/C<br />

(1 amp 1-Pole)<br />

Secondary Control Transformer Calculations (120 / 24V)<br />

Transformer<br />

VA<br />

Secondary<br />

Volts<br />

Rated<br />

Amps ➊<br />

Selected<br />

L8 Mini-CB<br />

50 120 0.42 1<br />

100 120 0.83 2<br />

150 120 1.25 2<br />

200 120 1.67 3<br />

250 120 2.08 4<br />

300 120 2.50 4<br />

500 120 4.17 7<br />

1000 120 8.33 13<br />

50 24 2.08 4<br />

100 24 4.17 7<br />

150 24 6.25 10<br />

200 24 8.33 13<br />

250 24 10.42 13<br />

300 24 12.50 16<br />

500 24 20.83 30<br />

1000 24 41.67 50<br />

Protection of Control <strong>Circuit</strong> Devices<br />

Control circuit devices can also generate inrush currents during<br />

startup, though not as intense as control transformers. Devices such as<br />

control relays, starter coils, and solenoids exhibit typical inrush levels<br />

between 6~10 x In. Also, protection of conductor wires or low-level<br />

signal devices such as PLCs may exhibit even lower inrush levels<br />

ranging from 3~5 x In. Depending on the inrush, an Mini-CB with a<br />

type “B” or “C” trip characteristic will perform the task.<br />

Control <strong>Circuit</strong> Conductor Protection<br />

The relationship between the control circuit conductor size and<br />

rating of the protective device must be in compliance with the<br />

tabulated data per UL 508.<br />

(Reference: UL 508A procedure prescribed only)<br />

Where can supplementary overcurrent<br />

protectors not be used?<br />

• Branch <strong>Circuit</strong> Protection Device (BCPD)<br />

• Power Transformer Primary Protection<br />

• Power Transformer Secondary Protection<br />

• Protection of Loads such as for <strong>Motor</strong>s, Heater, Lamps, and<br />

General use<br />

Supplementary protectors may be submitted to UL for further investigation<br />

for other uses.<br />

Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />

FH7<br />

➊ If the rated secondary current is less than 9 amps, the maximum rating of the overcurrent<br />

device is 167%. If 9 amps or more, the maximum rating of the overcurrent<br />

device is 125%.<br />

M26<br />

Discount Schedule B-7


<strong>Circuit</strong> Protection Methods<br />

Series L8 Supplementary Protectors<br />

Applying L8 Supplementary Protectors in accordance with UL & NEC Guidelines<br />

Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />

Sprecher+Schuh Series L8 Supplementary Protectors are recognized<br />

by Underwriters Laboratories (UL). Representative samples of this<br />

product have been evaluated by UL and meet applicable US safety<br />

standards. In general, the UL Component Recognition service covers<br />

the evaluation of components that will later be used in a complete<br />

product or system. L8 Supplementary Protectors are defined as UL<br />

Recognized supplementary overcurrent protective devices under the<br />

standard of UL 1077.<br />

UL 508A, a procedure covering industrial control panels, offers guidelines<br />

in applying supplementary overcurrent protective devices. The<br />

general areas of acceptability are in the primary and secondary protection<br />

of control transformers, and also control circuit protection. Other<br />

uses of Mini-CB’s may be submitted to UL for further investigation.<br />

Per UL 508A, before utilizing a supplementary device for control<br />

transformer overcurrent protection, the supplementary device<br />

must meet the following restrictions:<br />

Unless otherwise specified it is used with protection, either fuse or<br />

circuit breakers upstream from the supplementary device, rated<br />

at 400 percent of the supplementary protector rating but not less<br />

than 20A for device rated 150V or less and 15A for devices rated<br />

150V or more.<br />

(Reference: UL 508A procedure prescribed only)<br />

Protection of Control Transformers<br />

Control transformers can generate an almost infinite current spike<br />

on start-up while attempting to overcome core saturation. Only the<br />

resistance of the control transformer windings and the inductance of<br />

the circuit limit the large current draw. The inrush spikes are of short<br />

duration (1/8 to 1/4 of a cycle), typically reaching between 8~20 x<br />

I n . Therefore, selecting a Mini-CB with the proper current rating and<br />

high inrush trip characteristics is ideal to avoid nuisance tripping.<br />

Sprecher+Schuh Series L8 “C” & “D” type Supplementary Protectors<br />

offer high inrush capabilities from 5~10 x I n and 10~20 x I n respectively.<br />

Selecting the proper Mini-CB current ratings for the primary and secondary<br />

protection of control transformers (per UL/NEC) is as follows:<br />

Primary Overcurrent Protection for Control Transformers<br />

Control <strong>Circuit</strong>s: If the rated primary current is less than 2<br />

amps, the maximum rating of the overcurrent device is 500%.<br />

If the rated primary current is more than 2 amps, the maximum<br />

rating of the overcurrent device is 250%.<br />

Secondary Overcurrent Protection for Control Transformers<br />

Control <strong>Circuit</strong>s: If the rated secondary current is less than 9<br />

amps, the maximum rating of the overcurrent device is 167%.<br />

If 9 amps or more, the maximum rating of the overcurrent<br />

device is 125%. The next larger size of an overcurrent device<br />

may be used if 125% does not correspond to a standard size.<br />

(Reference: UL 508 32.7, UL 845 11.16 & 11.17, NEC 430-72(c)<br />

exception No. 2, 450-3(b) 1 & 2)<br />

Example (see table for more calculated results)<br />

Primary & Secondary Protection of a Control Transformer:<br />

50VA Pri. 480/ Sec. 120V<br />

Primary Mini-CB Selection<br />

• 50VA/480V = 0.10A rated transformer primary current<br />

• 0.10A is less than 2, therefore may increase up to 500%<br />

• 0.10A x 500% = 0.52A, Select L8-.5/2/D (0.5 amp 2-Pole)<br />

• Upstream BCPD must be rated at 400% of the selected Mini-CB<br />

rating<br />

• 0.5A x 400% = 2A, since rated below 15A at 150V or more, the<br />

minimum BCPD is 15A per NEC-240.6<br />

Primary Control Transformer Calculations (480 / 240V)<br />

Transformer<br />

VA<br />

Primary<br />

Volts<br />

Rated<br />

Amps ➊<br />

Selected<br />

L8 Mini-CB<br />

Maximum<br />

Upstream<br />

BCPD ➋<br />

50 480 0.10 0.5 15A<br />

100 480 0.21 1 15A<br />

150 480 0.31 1 15A<br />

200 480 0.42 2 15A<br />

250 480 0.52 2 15A<br />

300 480 0.63 3 15A<br />

500 480 1.04 5 25A<br />

1000 480 2.08 5 25A<br />

50 240 0.21 1 15A<br />

100 240 0.42 2 15A<br />

150 240 0.63 3 15A<br />

200 240 0.83 4 15A<br />

250 240 1.04 5 25A<br />

300 240 1.25 6 25A<br />

500 240 2.08 5 25A<br />

1000 240 4.17 10 60A<br />

➊ If the rated primary current is less than 2 amps, the maximum rating of the<br />

overcurrent device is 500%. If the rated primary current is more than 2 amps, the<br />

maximum rating of the overcurrent device is 250%.<br />

➋ Minimum standard BCPD ampere rating is 15A per NEC-240.6.<br />

M<br />

<strong>Circuit</strong><br />

Protection<br />

L8<br />

Discount Schedule B-8<br />

M27


<strong>Circuit</strong> Protection Methods<br />

Series L9 UL489 Miniature <strong>Circuit</strong> Breakers<br />

M<br />

<strong>Circuit</strong><br />

Protection<br />

Applying L9 UL489 Miniature <strong>Circuit</strong> Breakers in accordance with UL & NEC Guidelines<br />

Description<br />

L9 <strong>Circuit</strong> Breakers for Branch <strong>Circuit</strong> protection are available one (1)-,<br />

two (2-), and three (3-) pole construction and are rated 0.5 to 40A at<br />

240VC AC and 0.5 to 20A at 480Y/277V AC for North American<br />

applications (UL 489 and CSA 22.2 No. 5.1). For IEC applications, the<br />

products are rated 415V AC 0.5 to 40A.<br />

Thermal Magnetic <strong>Circuit</strong> Breakers<br />

The L9 Thermal Magnetic <strong>Circuit</strong> Breakers are general-purpose devices suitable<br />

for the majority of industrial, inverse time circuit breaker applications.<br />

<strong>Circuit</strong> Breaker Application Information<br />

Selection of a L9 circuit breaker with appropriate circuit protection includes<br />

consideration of:<br />

● <strong>Circuit</strong> Voltage<br />

● <strong>Circuit</strong> Frequency<br />

● Available Short <strong>Circuit</strong> Current<br />

● Continuous Current Rating<br />

● Application Considerations<br />

● Special Operating Conditions<br />

<strong>Circuit</strong> Voltage<br />

The L9 circuit breakers are rated by voltage class. Applications should not<br />

exceed the listed voltage and current range.<br />

<strong>Circuit</strong> Frequency<br />

The L9 circuit breakers may be applied to frequencies of 50 and 60 Hz without<br />

derating. For applications above 60 Hz, contact Sprecher + Schuh with<br />

specific application information for the derating of the circuit breakers.<br />

Available Short <strong>Circuit</strong> Current<br />

The L9 circuit breakers should only be applied in those applications in<br />

which the available short-circuit (or fault) current is less than or equal to<br />

10,000 A.<br />

Region Max. Voltage Current Range<br />

IEC Regions 415V AC 0.5..40A<br />

North America 240V AC 0.5...40A<br />

(UL 489 & CSA<br />

22.2 No. 5.1) 480Y/277V AC 0.5...20A<br />

Application Considerations<br />

The selection of a specific ampere rating for a specific application is<br />

dependent on the type of load and duty cycle and is governed by the<br />

National <strong>Electric</strong> Code (Canadian <strong>Electric</strong> Code) and UL/CSA. In<br />

general, the codes require that overcurrent protection is at the current<br />

supply and at points where wire sizes are reduced. In addition, the<br />

codes state that conductors be protected according to their current<br />

carrying capacity. There are specific situations that require application<br />

consideration, such as motor circuit, and guidelines for the selection<br />

for transformer protection.<br />

The L9 circuit breakers are "non 100% rated" as defined UL 489, para<br />

7.1.4.2. As such, the circuit breaker's rating should be loaded to no<br />

more than 80% if used with continuous loads.<br />

Branch <strong>Circuit</strong>s<br />

L9 circuit breakers may be used to protect branch circuits. A branch<br />

circuit is the wiring portion of a system extending beyond the final<br />

overcurrent device protecting the circuit. Guidelines established in<br />

NEC, CED, UL and CSA should be used to determine the specific<br />

device.<br />

1. <strong>Motor</strong> Branch <strong>Circuit</strong><br />

L9 circuit breakers are not horsepower rated because they are able<br />

to safely interrupt currents far in excess of the locked rotor value<br />

for a selected motor. This ability is recognized in the codes and<br />

standards and is also established by the UL and CSA tests described<br />

in UL 489 and CSA 22.2 No 5.1 standards.<br />

2. Transformer Protection<br />

L9 circuit breakers may be used for transformer protection following<br />

the guidelines established. References: NEC 450 and UL 489.<br />

Also see CEC and appropriate Canadian Standards. References:<br />

NEC 450 and UL 489. Also see CEC and appropriate Canadian<br />

Standards.<br />

3. Heater Load, Lighting, and Other Load Protection<br />

L9 circuit breakers may be used for protection of heater loads,<br />

lighting loads and other loads following the guidelines established.<br />

References: NED Article 31 and UL 508A. Also see CEC and appropriate<br />

Canadian Standards.<br />

Coordinated Overcurrent Protection<br />

Where an orderly shutdown is required to minimize the hazards to<br />

personnel and equipment, a system of coordination based upon the<br />

faulted or overloaded circuit is isolated by selective operation of only<br />

the overcurrent protective device closest to the overcurrent condition.<br />

The user should select devices that meet this requirement. References:<br />

NEC 240.12. Also see CEC.<br />

Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />

L9<br />

M28


<strong>Circuit</strong> Protection Methods<br />

Series L9 UL489 Miniature <strong>Circuit</strong> Breakers<br />

Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />

Applying L9 UL489 Miniature <strong>Circuit</strong> Breakers in accordance with UL & NEC Guidelines (continued)<br />

Determining Ratings<br />

The standard tripping characteristics for the L9 Series is Type C Type C has a magnetic trip activated at 5...10 times the rated current of the circuit<br />

breaker. The reference temperature for the thermal tripping characteristics is 40°C. The Type C characteristics will suit most applications.<br />

In rare occurrences when the Type C characteristics does not fully meet the application, the following additional magnetic trip characteristics is available.<br />

Type D allows for transient approximately twice as high as the standard Type C. Use the table and graphs to determine the current rating for the<br />

breaker if the ambient is significantly different than 40°C.<br />

Load Factor K T [I/I n ]<br />

Device Marked<br />

In (A) at higher Ambient Temperature<br />

Current Rating in<br />

(A) @ 40°C<br />

15°C 20°C 25°C 30°C 40°C 50°C 55°C<br />

0.5 0.6 0.5 0.5 0.5 0.5 0.5 0.5<br />

1.0 1.1 1.1 1.1 1.0 1 1.0 0.9<br />

1.5 1.7 1.6 1.6 1.6 1.5 1.4 1.4<br />

2.0 2.2 2.2 2.1 2.1 2 1.9 1.9<br />

3.0 3.3 3.2 3.2 3.1 3 2.9 2l.8<br />

4.0 4.4 4.3 4.2 4.2 4 3.8 3.8<br />

5.0 5.5 5.4 5.3 5.2 5 4.8 4.7<br />

6.0 6.6 6.5 6.4 6.2 6 5.8 5.6<br />

7.0 7.7 7.6 7.4 7.3 7 6.7 6.6<br />

8.0 8.8 8.6 8.5 8.3 8 7.7 7.5<br />

10.0 11.0 10.8 10.6 10.4 10 9.6 9.4<br />

13.0 14.3 14.0 13.8 13.5 13 12.5 12.2<br />

15.0 16.5 16.2 15.9 15.6 15 14.4 14.1<br />

16.0 17.6 17.3 17.0 16.6 16 15.4 15.0<br />

20.0 22.0 21.6 21.2 20.8 20 19.2 18.8<br />

25.0 27.5 27.0 26.5 26.0 25 24.0 23.5<br />

30.0 33.0 32.4 31.8 31.2 30 28.8 28.2<br />

32.0 35.2 34.6 33.9 33.3 32 30.7 30.1<br />

40.0 44.0 43.2 42.4 41.6 40 38.4 37.6<br />

Note: The table shows the corrected values of the rated current dependent on the ambient temperature.<br />

1.40<br />

1.30<br />

1.20<br />

1.10<br />

1.00<br />

0.90<br />

Influence of Ambient Temperature (T)<br />

on Load-Carrying Capacity<br />

-20 -10 0 10 20 30 50 50<br />

Ambient Temperature T [°C]<br />

Maximum load I at Ambient Temperature T:<br />

L<br />

I L(T) = I n K T (T)<br />

t [sec]<br />

7200<br />

3600<br />

1<br />

1200<br />

600<br />

300<br />

120<br />

60<br />

30<br />

10<br />

5<br />

2<br />

1<br />

0.5<br />

0.2<br />

0.1<br />

0.05<br />

0.02<br />

0.01<br />

0.005<br />

0.002<br />

0.001<br />

0.0005<br />

2<br />

3<br />

3<br />

Time-Current Characteristic L9<br />

Type C and D<br />

Ambient Temperature 40°C<br />

4 5<br />

4 5<br />

Tripping characteristic<br />

acc. to UL 489<br />

1 conventional non-tripping current<br />

Int = 1.0 I (TN =40°C)<br />

2 conventional tripping current<br />

It = 1.35 I : tN < 1 h (T=25°C)<br />

3 2.0 I : tN = 12- 120 s (T=25°C)<br />

4<br />

6<br />

Instantaneous Tripping<br />

acc. to IEC 60898-1<br />

type C: 5 I : t > 0.1N s<br />

10 I : t < 0.1N s<br />

type D: 10 I : t > 0.1N s<br />

20 I : t < 0.1N s<br />

M<br />

<strong>Circuit</strong><br />

Protection<br />

L9<br />

1 2 3 4 5 6 7 8 9 10 15 20 30 40 50<br />

I / I<br />

N<br />

M29


<strong>Circuit</strong> Protection Methods<br />

Series L8 and L9<br />

Defining <strong>Electric</strong>al Standards Relating to Supplementary Protectors<br />

M<br />

<strong>Circuit</strong><br />

Protection<br />

➊<br />

➐<br />

➊ Branch <strong>Circuit</strong> Protection Device (BCPD)<br />

Acceptable components<br />

• Branch circuit protection device (UL489)<br />

• Self-protected Type E manual motor controller<br />

➋ Control Transformer Primary Protection<br />

Acceptable components<br />

• UL-1077 supplementary protective device<br />

• Self-protected Type E manual motor controller<br />

• UL-listed fuses<br />

➌ Control Transformer Secondary Protection<br />

Acceptable components<br />

• UL-1077 supplementary protective device<br />

• Self-protected Type E manual motor controller<br />

• Miscellaneous, miniature and micro fuses<br />

➍ Supplementary <strong>Circuit</strong> Protection<br />

Acceptable components<br />

• UL-1077 supplementary protective device<br />

• Miscellaneous, miniature and micro fuses<br />

➌<br />

➍<br />

➎ Power Transformer Fuse/Branch <strong>Circuit</strong><br />

Protection<br />

Acceptable components<br />

• Branch circuit protection device or power-related transformer<br />

fuses (UL489)<br />

• Self-protected Type E manual motor controller<br />

➏ Power Transformer Fuse/Branch <strong>Circuit</strong><br />

Protection<br />

Acceptable components<br />

• Branch circuit protection device or power-related transformer<br />

fuses (UL489)<br />

• Self-protected Type E manual motor controller<br />

➋<br />

➊<br />

➊<br />

➎<br />

➏<br />

➐<br />

➌<br />

➍<br />

L10 Disconnect Switch<br />

<strong>KT7</strong> <strong>Motor</strong> <strong>Circuit</strong> Protector<br />

V7 Fuse Blocks<br />

➏<br />

➐<br />

➎<br />

Sprecher + Schuh Products<br />

➋<br />

➌<br />

➍<br />

➎<br />

➏<br />

➋<br />

➍<br />

➊<br />

➋<br />

➎<br />

➏<br />

FH7 Fuse Holder<br />

L8 Supplementary Protector<br />

L9 Miniature <strong>Circuit</strong> Breaker<br />

Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />

L9<br />

➐ <strong>Motor</strong> Load Protection<br />

• <strong>Manual</strong> motor controllers (UL508)<br />

M30 Discount Schedule B-8


<strong>Circuit</strong> Protection Methods<br />

Series L8 and L9<br />

Defining <strong>Electric</strong>al Standards Relating to Supplementary Protectors<br />

Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />

<strong>Circuit</strong> protection devices should be applied in accordance with the<br />

product specifications, as well as local and national electrical codes.<br />

Sprecher+Schuh breakers offer equipment manufacturers a product<br />

that meets both US and international protection standards. A variety<br />

of Sprecher+Schuh Supplementary Protectors are approved by Underwriters<br />

Laboratory’s UL 1077 supplementary standards and are<br />

applicable for use under the guidelines of the National <strong>Electric</strong> Code<br />

(NEC). Internationally, Sprecher+Schuh Supplementary Protectors<br />

are CE marked and meet CSA and IEC standards for worldwide acceptance.<br />

Sprecher+Schuh Supplementary Protectors are an excellent choice<br />

for supplementary protection. See the listings below to gain a<br />

broader understanding of additional electrical standards pertaining to<br />

other types of Supplementary Protectors.<br />

UL 508 <strong>Manual</strong> <strong>Motor</strong> <strong>Controllers</strong><br />

A manual motor controller is suitable for use as an ON/OFF<br />

R<br />

(make/break) controller for motors and other loads. These<br />

devices also have an overload tripping function which must be<br />

compliant with applicable tests for an overload relay. In addition, an<br />

overload tripping device must operate independently of the manipulation<br />

of the handle (trip free).<br />

A listed <strong>Manual</strong> <strong>Motor</strong> Controller, additionally marked “Suitable as<br />

a <strong>Motor</strong> Disconnect,” shall be permitted as a disconnecting means<br />

where installed between the final motor branch-circuit short-circuit,<br />

transformer protection, device and the motor. General uses: control<br />

circuit, transformer protection, motor loads, general use loads, lighting<br />

loads, resistive loads.<br />

Although Sprecher+Schuh Supplementary Protectors are not listed as<br />

UL 508 manual motor controllers, Sprecher + Schuh offers our <strong>KT7</strong><br />

<strong>Motor</strong> Controller series, which does meet the UL 508 standard at a<br />

competitive price.<br />

UL 489 Branch <strong>Circuit</strong> Protection<br />

Products UL Listed for Branch <strong>Circuit</strong> Protection, which are<br />

approved and evaluated according to the UL 489 Standard<br />

R<br />

for “Molded Case <strong>Circuit</strong> Breakers” (usually applicable at 240V<br />

maximum when associated with Supplementary Protectors). General<br />

uses: Branch <strong>Circuit</strong> Protection Device (BCPD), protect motor loads,<br />

protect external loads such as receptacles or HVAC & refrigeration<br />

equipment.<br />

Although Sprecher+Schuh Supplementary Protectors are not listed as<br />

UL 489 branch circuit protectors, Sprecher + Schuh offers our <strong>KT7</strong><br />

<strong>Motor</strong> Controller series which is approved as a self-protected combination<br />

motor controller under UL 508 and therefore can be applied as<br />

a branch circuit protection device.<br />

CSA C22.2 No. 5.1<br />

Products evaluated according to the Canadian Standards<br />

Association (CSA), which are intended to protect branch circuits<br />

in accordance with the Canadian <strong>Electric</strong> Code (CEC). The CSA<br />

C22.2 No. 5.1 standard is closely related to the UL 489 standard.<br />

UL 1077 Supplementary Protection<br />

UL recognized supplementary protectors evaluated according<br />

to UL 1077 standard. Supplementary protectors are intended<br />

for use as overcurrent protection within an appliance or other electrical<br />

equipment where branch circuit protectors shall not be used as<br />

substitutes for UL 489 branch circuit protective devices. General uses:<br />

control circuit components such as relay coils, starter coils, timers and<br />

remote solenoids... etc.; control transformers protection (primary &<br />

secondary); sensitive internal electronic circuitry.<br />

CSA C22.2 No. 235<br />

The CSA C22.2 No. 235 Standard is closely related to the UL<br />

1077 Supplementary Protector standard.<br />

IEC 60947-2 Standard<br />

<strong>Electric</strong>al standards for industrial applications using circuit<br />

protection.<br />

M<br />

<strong>Circuit</strong><br />

Protection<br />

L9<br />

Discount Schedule B-8<br />

M31


Notes<br />

Series L8 and L9<br />

Notes<br />

M<br />

<strong>Circuit</strong><br />

Protection<br />

Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />

L9<br />

M32 Discount Schedule B-8


R<br />

Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />

Series FH7<br />

DIN-rail Mounted<br />

Fuse Holders<br />

The new design<br />

standard for fuse block<br />

overcurrent protection<br />

New FH7 Fuse Holders have a<br />

completely enclosed design that<br />

makes changing fuses simple<br />

and safe<br />

Sprecher + Schuh’s new FH7 Fuse<br />

Blocks feature the latest enclosed design<br />

for the ultimate in safety and convenience.<br />

Built for control and power<br />

circuits, the FH7 line is DIN-rail<br />

mountable, compact and reliable. Both<br />

AC and DC models are available, with<br />

and without blown fuse indication.<br />

Sized for many applications<br />

FH7 Fuse Blocks are available in one,<br />

two and three pole configurations for<br />

the following fuse types:<br />

• Class CC<br />

• Midget; 1-1/2 x 13/32<br />

• DC rated fuses up to 30A<br />

• Class J 30A fuses<br />

• Class J 60A fuses<br />

All AC fuse blocks are rated to 600V,<br />

with 24 and 48V DC models available<br />

for midget fuses. All devices carry<br />

a withstand rating to 200kA. Midget<br />

fuse blocks are rated to 100kA.<br />

New enclosed design offers<br />

many advantages<br />

Unlike “open” fuse blocks of the past<br />

that were extremely dangerous, the<br />

enclosed design of the FH7 series<br />

features IP2 dead-front construction<br />

under IEC and DIN standards. In<br />

operation, there is no access to live<br />

fuses or fuse clips. With the flick of<br />

a finger, fuse access is gained via a levered<br />

compartment on the front of the<br />

holder that isolates the fuse from the<br />

line power. This makes fuse changeout<br />

quick, easy, convenient... and safe.<br />

Other great features<br />

The FH7 line is compact, saving up to<br />

15% in panel space over conventional<br />

fuse blocks. The entire line is also<br />

DIN-rail mountable, resulting in extra<br />

savings in panel building time. All<br />

models are available with blown fuse<br />

indication, saving time on maintenance<br />

and troubleshooting. The bodies<br />

are made up of tough and durable<br />

polyamide, known for its exceptional<br />

insulating properties.<br />

International approvals<br />

Class CC and J fuse holders are UL<br />

listed for branch circuit protection in<br />

electrical distribution systems. They<br />

are excellent for small motor loads<br />

and group protection of small motors.<br />

Midget holders are UL recognized.<br />

The entire line is CSA Approved and<br />

carries the CE Mark for use in international<br />

markets.<br />

M<br />

<strong>Circuit</strong><br />

Protection<br />

17.5mm 17.5mm 37.5mm 40mm<br />

(≈11/16˝) (≈11/16˝) (≈1-15/32˝) (≈1-9/16˝)<br />

Midget Class CC Class J (30A) Class J (60A)<br />

M33<br />

FH7


Series FH7 Fuse Holders<br />

For Midget Fuses<br />

M<br />

<strong>Circuit</strong><br />

Protection<br />

DIN-rail Mounted Fuse Holders – Midget Fuses (13/32 x 1-1/2) ➊<br />

Ordering and<br />

Technical<br />

Information<br />

Fuse Block -<br />

Without Blown Fuse LED<br />

With Blown Fuse LED<br />

24V DC (with LED indicator)<br />

48V DC (with LED indicator)<br />

DIN-rail<br />

Top Hat, low profile (priced per rail)<br />

Top Hat, high profile (priced per rail)<br />

End Anchors<br />

DIN Rail — Normal Duty<br />

DIN Rail — Heavy Duty<br />

Catalog Number<br />

FH7-1PM30<br />

FH7-1PM30-L<br />

FH7-1PM30-D1<br />

FH7-1PM30-D2<br />

3F<br />

3AF<br />

V7-EA35<br />

V7-EAH35<br />

One Pole<br />

2.13"<br />

0.69" (17.5mm) (54mm)<br />

Price Ea.<br />

(Std Pkg)<br />

11.40<br />

16.90<br />

16.90<br />

16.90<br />

17.00<br />

26.00<br />

1.15<br />

4.35<br />

Pkg<br />

Qty<br />

6<br />

6<br />

6<br />

6<br />

Catalog Number<br />

FH7-2PM30<br />

FH7-2PM30-L<br />

Accessories<br />

12<br />

12<br />

50<br />

10<br />

3F<br />

3AF<br />

V7-EA35<br />

V7-EAH35<br />

Two Pole<br />

2.13"<br />

1.38" (35mm) (54mm)<br />

Price Ea.<br />

(Std Pkg)<br />

23.30<br />

34.80<br />

17.00<br />

26.00<br />

1.15<br />

4.35<br />

Pkg<br />

Qty<br />

3<br />

3<br />

12<br />

12<br />

50<br />

10<br />

Catalog Number<br />

FH7-3PM30<br />

FH7-3PM30-L<br />

3F<br />

3AF<br />

V7-EA35<br />

V7-EAH35<br />

Three Pole<br />

2.13"<br />

2.07" (52.5mm) (54mm)<br />

Price Ea.<br />

(Std Pkg)<br />

Fuse Block Specifications<br />

Approvals<br />

Voltage Rating 600V AC/DC 600V AC/DC 600V AC/DC 600V AC/DC 600V AC/DC 600V AC/DC<br />

Maximum Current 30 A 30 A 30 A 30 A 30 A 30 A<br />

Wire Range (Rated Cross Section) #14–#6 AWG<br />

2.5…16mm 2<br />

#14–#6 AWG<br />

2.5…16mm 2<br />

#14–#6 AWG<br />

2.5…16mm 2<br />

#14–#6 AWG<br />

2.5…16mm 2<br />

#14–#6 AWG<br />

2.5…16mm 2<br />

#14–#6 AWG<br />

2.5…16mm 2<br />

Wire Strip Length 0.5" (12.7 mm) 0.5" (12.7 mm) 0.5" (12.7 mm)<br />

Recommended Tightening Torque 15 lb-in. (1.7 Nm) 15 lb-in. (1.7 Nm) 15 lb-in. (1.7 Nm)<br />

Working Voltage (indicating circuit)<br />

FH7-1PM30-D1<br />

FH7-1PM30-D2<br />

Leakage Current (indicating circuit)<br />

FH7-1PM30-D1<br />

FH7-1PM30-D2<br />

95…600V AC; 115…600V DC<br />

12…24V DC<br />

35…48V DC<br />

0.8mA max. @ 600V<br />

10mA @ 24V<br />

10mA @ 48V<br />

95…600V AC; 115…600V DC<br />

~<br />

~<br />

0.8mA max. @ 600V<br />

~<br />

~<br />

35.00<br />

52.20<br />

17.00<br />

26.00<br />

1.15<br />

4.35<br />

95…600V AC; 115…600V DC<br />

~<br />

~<br />

0.8mA max. @ 600V<br />

~<br />

~<br />

Withstand Rating 100kA 100kA 100kA<br />

Fuse Type Midget fuses only ➊ Midget fuses only ➊ Midget fuses only ➊<br />

Temperature Range –40°…+221°F (–40°…+105°C) –40°…+221°F (–40°…+105°C) –40°…+221°F (–40°…+105°C)<br />

Common Midget Fuse Applications<br />

• Transformer secondary protection<br />

• Supplemental protection of:<br />

- Control circuits<br />

- Lighting<br />

- Solenoids<br />

3.07" (78mm)<br />

3.07" (78mm)<br />

Typical Midget Fuse Dimensions<br />

3.07" (78mm)<br />

Pkg<br />

Qty<br />

2<br />

2<br />

12<br />

12<br />

50<br />

10<br />

Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />

FH7<br />

➊ Fuses not offered by Sprecher + Schuh.<br />

M34<br />

Discount Schedule B-7


R R R<br />

Series FH7 Fuse Holders<br />

For Class CC Fuses<br />

Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />

DIN-rail Mounted Fuse Holders – Class CC Fuses ➊<br />

Ordering and<br />

Technical<br />

Information<br />

Fuse Block -<br />

Without Blown Fuse LED<br />

With Blown Fuse LED<br />

DIN-rail<br />

Top Hat, low profile (priced per rail)<br />

Top Hat, high profile (priced per rail)<br />

End Anchors<br />

DIN Rail — Normal Duty<br />

DIN Rail — Heavy Duty<br />

Catalog Number<br />

FH7-1PC30<br />

FH7-1PC30-L<br />

3F<br />

3AF<br />

V7-EA35<br />

V7-EAH35<br />

One Pole<br />

2.13"<br />

0.69" (17.5mm) (54mm)<br />

Price Ea.<br />

(Std Pkg)<br />

10.70<br />

16.10<br />

17.00<br />

26.00<br />

1.15<br />

4.35<br />

Pkg<br />

Qty<br />

6<br />

6<br />

Catalog Number<br />

FH7-2PC30<br />

FH7-2PC30-L<br />

Accessories<br />

12<br />

12<br />

50<br />

10<br />

3F<br />

3AF<br />

V7-EA35<br />

V7-EAH35<br />

Two Pole<br />

2.13"<br />

1.38" (35mm) (54mm)<br />

Price Ea.<br />

(Std Pkg)<br />

23.10<br />

34.30<br />

17.00<br />

26.00<br />

1.15<br />

4.35<br />

Pkg<br />

Qty<br />

3<br />

3<br />

12<br />

12<br />

50<br />

10<br />

Catalog Number<br />

FH7-3PC30<br />

FH7-3PC30-L<br />

3F<br />

3AF<br />

V7-EA35<br />

V7-EAH35<br />

Three Pole<br />

2.13"<br />

2.07" (52mm) (54mm)<br />

Price Ea.<br />

(Std Pkg)<br />

Fuse Block Specifications<br />

Approvals<br />

Voltage Rating 600V AC/DC 600V AC/DC 600V AC/DC 600V AC/DC 600V AC/DC 600V AC/DC<br />

Maximum Current 30 A 30 A 30 A 30 A 30 A 30 A<br />

Wire Range (Rated Cross Section) #14–#6 AWG<br />

2.5…16mm 2<br />

#14–#6 AWG<br />

2.5…16mm 2<br />

#14–#6 AWG<br />

2.5…16mm 2<br />

#14–#6 AWG<br />

2.5…16mm 2<br />

#14–#6 AWG<br />

2.5…16mm 2<br />

#14–#6 AWG<br />

2.5…16mm 2<br />

Wire Strip Length 0.5" (12.7 mm) 0.5" (12.7 mm) 0.5" (12.7 mm)<br />

Recommended Tightening Torque 15 lb-in. (1.7 Nm) 15 lb-in. (1.7 Nm) 15 lb-in. (1.7 Nm)<br />

Working Voltage (indicating circuit) 95…600V AC; 115…600V DC 95…600V AC; 115…600V DC 95…600V AC; 115…600V DC<br />

Leakage Current (indicating circuit) 0.8mA max. @ 600V 0.8mA max. @ 600V 0.8mA max. @ 600V<br />

Withstand Rating 200kA 200kA 200kA<br />

Fuse Type Class CC fuses only ➊ Class CC fuses only ➊ Class CC fuses only ➊<br />

Temperature Range –40°…+221°F (–40°…+105°C) –40°…+221°F (–40°…+105°C) –40°…+221°F (–40°…+105°C)<br />

Common Class CC Applications<br />

• Control transformer protection<br />

• <strong>Motor</strong> circuits<br />

• Branch circuit protection<br />

• Lighting loads<br />

• General purpose loads<br />

• Heating loads<br />

3.07" (78mm)<br />

3.07" (78mm)<br />

Typical Class CC Fuse Dimensions<br />

3.07" (78mm)<br />

34.90<br />

52.00<br />

17.00<br />

26.00<br />

1.15<br />

4.35<br />

Pkg<br />

Qty<br />

2<br />

2<br />

12<br />

12<br />

50<br />

10<br />

M<br />

<strong>Circuit</strong><br />

Protection<br />

➊ Fuses not offered by Sprecher + Schuh.<br />

FH7<br />

Discount Schedule B-7<br />

M35


R R R<br />

Series FH7 Fuse Holders<br />

For Class J Fuses, 30A<br />

M<br />

<strong>Circuit</strong><br />

Protection<br />

DIN-rail Mounted Fuse Holders – Class J Fuses, 30A ➊<br />

Ordering and<br />

Technical<br />

Information<br />

Fuse Block -<br />

Without Blown Fuse LED<br />

With Blown Fuse LED<br />

DIN-rail<br />

Top Hat, low profile (priced per rail)<br />

Top Hat, high profile (priced per rail)<br />

End Anchors<br />

DIN Rail — Normal Duty<br />

DIN Rail — Heavy Duty<br />

4.41" (112mm)<br />

Catalog Number<br />

FH7-1PJ30<br />

FH7-1PJ30-L<br />

3F<br />

3AF<br />

V7-EA35<br />

V7-EAH35<br />

One Pole<br />

2.59"<br />

1.48" (37.5mm) (73.5mm)<br />

Price Ea.<br />

(Std Pkg)<br />

23.40<br />

27.30<br />

17.00<br />

26.00<br />

1.15<br />

4.35<br />

Pkg<br />

Qty<br />

6<br />

6<br />

Catalog Number<br />

FH7-2PJ30<br />

FH7-2PJ30-L<br />

Accessories<br />

12<br />

12<br />

50<br />

10<br />

3F<br />

3AF<br />

V7-EA35<br />

V7-EAH35<br />

Two Pole<br />

2.89"<br />

2.56" (65mm) (73.5mm)<br />

Price Ea.<br />

(Std Pkg)<br />

48.50<br />

56.00<br />

17.00<br />

26.00<br />

1.15<br />

4.35<br />

Pkg<br />

Qty<br />

3<br />

3<br />

12<br />

12<br />

50<br />

10<br />

Catalog Number<br />

FH7-3PJ30<br />

FH7-3PJ30-L<br />

3F<br />

3AF<br />

V7-EA35<br />

V7-EAH35<br />

Three Pole<br />

2.89"<br />

3.86" (98mm) (73.5mm)<br />

Price Ea.<br />

(Std Pkg)<br />

Fuse Block Specifications<br />

Approvals<br />

Voltage Rating 600V AC/DC 600V AC/DC 600V AC/DC 600V AC/DC 600V AC/DC 600V AC/DC<br />

Maximum Current 30 A 30 A 30 A 30 A 30 A 30 A<br />

Wire Range (Rated Cross Section) #14–#6 AWG<br />

2.5…16mm 2<br />

#14–#6 AWG<br />

2.5…16mm 2<br />

#14–#6 AWG<br />

2.5…16mm 2<br />

#14–#6 AWG<br />

2.5…16mm 2<br />

#14–#6 AWG<br />

2.5…16mm 2<br />

#14–#6 AWG<br />

2.5…16mm 2<br />

Wire Strip Length 0.5" (12.7 mm) 0.5" (12.7 mm) 0.5" (12.7 mm)<br />

Recommended Tightening Torque 35 lb-in. (3.95 Nm) 35 lb-in. (3.95 Nm) 35 lb-in. (3.95 Nm)<br />

Working Voltage (indicating circuit) 95…600V AC; 115…600V DC 95…600V AC; 115…600V DC 95…600V AC; 115…600V DC<br />

Leakage Current (indicating circuit) 0.8mA max. @ 600V 0.8mA max. @ 600V 0.8mA max. @ 600V<br />

Withstand Rating 200kA 200kA 200kA<br />

Fuse Type Class J fuses only ➊ Class J fuses only ➊ Class J fuses only ➊<br />

Temperature Range –40°…+221°F (–40°…+105°C) –40°…+221°F (–40°…+105°C) –40°…+221°F (–40°…+105°C)<br />

Common Class J Applications<br />

• <strong>Motor</strong> circuits<br />

• Feeders and mains<br />

• Branch circuit protection<br />

• Lighting, heating and general loads<br />

• Power transformers<br />

• Control transformers<br />

• Control circuits<br />

4.41" (112mm)<br />

4.41" (112mm)<br />

Typical Class J (1-30A) Fuse Dimensions<br />

72.80<br />

83.90<br />

17.00<br />

26.00<br />

1.15<br />

4.35<br />

Pkg<br />

Qty<br />

2<br />

2<br />

12<br />

12<br />

50<br />

10<br />

Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />

FH7<br />

➊ Fuses not offered by Sprecher + Schuh.<br />

M36<br />

Discount Schedule B-7


R R R<br />

Series FH7 Fuse Holders<br />

For Class J Fuses, 60A<br />

Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />

DIN-rail Mounted Fuse Holders – Class J Fuses, 60A ➊<br />

Ordering and<br />

Technical<br />

Information<br />

Fuse Block -<br />

Without Blown Fuse LED<br />

With Blown Fuse LED<br />

DIN-rail<br />

Top Hat, low profile (priced per rail)<br />

Top Hat, high profile (priced per rail)<br />

End Anchors<br />

DIN Rail — Normal Duty<br />

DIN Rail — Heavy Duty<br />

4.80" (122mm)<br />

Catalog Number<br />

FH7-1PJ60<br />

FH7-1PJ60-L<br />

3F<br />

3AF<br />

V7-EA35<br />

V7-EAH35<br />

One Pole<br />

3.23"<br />

1.57" (40mm) (82mm)<br />

Price Ea.<br />

(Std Pkg)<br />

26.70<br />

30.30<br />

17.00<br />

26.00<br />

1.15<br />

4.35<br />

Pkg<br />

Qty<br />

6<br />

6<br />

Catalog Number<br />

FH7-2PJ60<br />

FH7-2PJ60-L<br />

Accessories<br />

12<br />

12<br />

50<br />

10<br />

3F<br />

3AF<br />

V7-EA35<br />

V7-EAH35<br />

Two Pole<br />

3.23"<br />

3.15" (80mm) (82mm)<br />

Price Ea.<br />

(Std Pkg)<br />

54.90<br />

62.30<br />

17.00<br />

26.00<br />

1.15<br />

4.35<br />

Pkg<br />

Qty<br />

3<br />

3<br />

12<br />

12<br />

50<br />

10<br />

Catalog Number<br />

FH7-3PJ60<br />

FH7-3PJ60-L<br />

3F<br />

3AF<br />

V7-EA35<br />

V7-EAH35<br />

Three Pole<br />

3.23"<br />

4.72" (120mm) (82mm)<br />

Price Ea.<br />

(Std Pkg)<br />

Fuse Block Specifications<br />

Approvals<br />

Voltage Rating 600V AC/DC 600V AC/DC 600V AC/DC 600V AC/DC 600V AC/DC 600V AC/DC<br />

Maximum Current 60 A 60 A 60 A 60 A 60 A 60 A<br />

Wire Range (Rated Cross Section) #14–#6 AWG<br />

2.5…16mm 2<br />

#14–#6 AWG<br />

2.5…16mm 2<br />

#14–#6 AWG<br />

2.5…16mm 2<br />

#14–#6 AWG<br />

2.5…16mm 2<br />

#14–#6 AWG<br />

2.5…16mm 2<br />

#14–#6 AWG<br />

2.5…16mm 2<br />

Wire Strip Length 0.5" (12.7 mm) 0.5" (12.7 mm) 0.5" (12.7 mm)<br />

Recommended Tightening Torque 45 lb-in. (5.0 Nm) 45 lb-in. (5.0 Nm) 45 lb-in. (5.0 Nm)<br />

Working Voltage (indicating circuit) 95…600V AC; 115…600V DC 95…600V AC; 115…600V DC 95…600V AC; 115…600V DC<br />

Leakage Current (indicating circuit) 0.8mA max. @ 600V 0.8mA max. @ 600V 0.8mA max. @ 600V<br />

Withstand Rating 200kA 200kA 200kA<br />

Fuse Type Class J fuses only ➊ Class J fuses only ➊ Class J fuses only ➊<br />

Temperature Range –40°…+221°F (–40°…+105°C) –40°…+221°F (–40°…+105°C) –40°…+221°F (–40°…+105°C)<br />

Common Class J Applications<br />

• <strong>Motor</strong> circuits<br />

• Feeders and mains<br />

• Branch circuit protection<br />

• Lighting, heating and general loads<br />

• Power transformers<br />

• Control transformers<br />

• Control circuits<br />

4.80" (122mm)<br />

4.80" (122mm)<br />

Typical Class J (31-60A) Fuse Dimensions<br />

82.30<br />

93.50<br />

17.00<br />

26.00<br />

1.15<br />

4.35<br />

Pkg<br />

Qty<br />

2<br />

2<br />

12<br />

12<br />

50<br />

10<br />

M<br />

<strong>Circuit</strong><br />

Protection<br />

➊ Fuses not offered by Sprecher + Schuh.<br />

FH7<br />

Discount Schedule B-7<br />

M37


Fuse Block Selection Guide<br />

Series FH7 Fuse Holders<br />

M<br />

<strong>Circuit</strong><br />

Protection<br />

FH7<br />

Control Transformers - Primary ➊<br />

Transformer Max.<br />

Value<br />

Fuse<br />

Block<br />

Max.<br />

Value<br />

Fuse<br />

Block<br />

Max.<br />

Value<br />

Fuse<br />

Block<br />

Max.<br />

Value<br />

Fuse<br />

Block<br />

VA 208V 240V 480 575V<br />

50 1.125 30A 1.0 30A 0.5 30A 0.4 30A<br />

100 2.25 30A 2.0 30A 1.0 30A 0.6 30A<br />

150 3.5 30A 3.0 30A 1.5 30A 1.25 30A<br />

200 4.5 30A 4.0 30A 2.0 30A 1.6 30A<br />

250 6.0 30A 5.0 30A 2.5 30A 2.0 30A<br />

300 7.0 30A 6.25 30A 3.0 30A 2.5 30A<br />

500 6.0 30A 5.0 30A 5.0 30A 4.0 30A<br />

1000 12.0 30A 10.0 30A 5.0 30A 8.0 30A<br />

1500 17.5 30A 15.0 30A 7.5 30A 6.25 30A<br />

2000 20.0 30A 20.0 30A 10.0 30A 8.0 30A<br />

3000 35.0 60A 30.0 60A 15.0 30A 12.0 30A<br />

5000 60.0 60A 50.0 60A 25.0 30A 20.0 30A<br />

7500 ~ ~ ~ ~ 35.0 60A 30.0 60A<br />

10000 ~ ~ ~ ~ 50.0 60A 40.0 60A<br />

Control Transformers - Secondary<br />

Transformer Max.<br />

Value<br />

Fuse<br />

Block<br />

Max.<br />

Value<br />

Fuse<br />

Block<br />

VA 24V 120V<br />

50 3.2 30A 0.6 30A<br />

100 6.25 30A 1.25 30A<br />

150 10.0 30A 2.0 30A<br />

200 12.0 30A 2.5 30A<br />

250 15.0 30A 3.2 30A<br />

300 20.0 30A 4.0 30A<br />

500 30.0 30A 6.25 30A<br />

1000 60.0 60A 12.0 30A<br />

1500 ~ ~ 17.5 30A<br />

2000 ~ ~ 25.0 30A<br />

3000 ~ ~ 35.0 60A<br />

5000 ~ ~ 60.0 60A<br />

7500 ~ ~ ~ ~<br />

10000 ~ ~ ~ ~<br />

➊ Class CC and Class J fuses may be used for Primary Protection,<br />

contact fuse manufacturer for specific use.<br />

The Maximum Values listed in the tables are calculated from the following<br />

procedures, which can be found in the NEC . Always compute the Max.<br />

Value for your specific application prior to selecting a fuse block.<br />

Calculating NEC Maximum Values<br />

Selecting the proper fuse block current ratings for the primary and secondary protection<br />

of control transformers (per UL/NEC) is as follows:<br />

Primary Overcurrent Protection for Control Transformers<br />

Control <strong>Circuit</strong>s: If the rated primary current is less than 2 amps, the maximum<br />

rating of the overcurrent device is 500%. If the rated primary current is<br />

more than 2 amps, the maximum rating of the overcurrent device is 250%.<br />

Secondary Overcurrent Protection for Control Transformers<br />

Control <strong>Circuit</strong>s: If the rated secondary current is less than 9 amps, the<br />

maximum rating of the overcurrent device is 167%. If 9 amps or more, the<br />

maximum rating of the overcurrent device is 125%. The next larger size of an<br />

overcurrent device may be used if 125% does not correspond to a standard<br />

size.<br />

Reference: UL 508 19.3, NEC 430-72(c) exception No. 2, 450-3(b) 1 & 2<br />

Primary Fuse Block Selection Example:<br />

1000VA Transformer<br />

480V Primary<br />

1000/480 = 2.08 Amps [May increase by 250% if above 2A]<br />

2.08 x 250% = 5.21 Amps<br />

Select 30A FH7 Class CC fuse block for 5A Class CC Fuse<br />

Secondary Fuse Block Selection Example:<br />

5000VA Transformer<br />

120V Secondary<br />

5000/120 = 41.7 Amps [May increase by 125% if above 9A]<br />

41.7 x 125% = 52.1 Amps<br />

Select 60A FH7 Class J fuse block for 50A Class J Fuse<br />

Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />

M38<br />

Discount Schedule B-7


Fuse Block Selection Guide<br />

Series FH7 Fuse Holders<br />

Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />

Three Phase <strong>Motor</strong> Loads ➊➋➌<br />

Horsepower<br />

FLA<br />

Fuse<br />

Block<br />

FLA<br />

Fuse<br />

Block<br />

FLA<br />

Fuse<br />

Block<br />

FLA<br />

208V 240V 480V 575V<br />

Fuse<br />

Block<br />

1/2 2.4 30A 2.2 30A 1.1 30A 0.9 30A<br />

3/4 3.5 30A 3.2 30A 1.6 30A 1.3 30A<br />

1 4.6 30A 4.2 30A 2.1 30A 1.7 30A<br />

1-1/2 6.6 30A 6.0 30A 3.0 30A 2.4 30A<br />

2 7.5 30A 6.8 30A 3.4 30A 2.7 30A<br />

3 10.6 30A 9.6 30A 4.8 30A 3.9 30A<br />

5 16.8 30A 15.2 30A 7.6 30A 6.1 30A<br />

7-1/2 24.2 60A 22.0 60A 11.0 30A 9.0 30A<br />

10 30.8 60A 28.0 60A 14.0 30A 11.0 30A<br />

15 ~ ~ 42.0 60A 21.0 30A 17.0 30A<br />

20 ~ ~ ~ ~ 27 60A 22.0 60A<br />

25 ~ ~ ~ ~ 34 60A 27.0 60A<br />

30 ~ ~ ~ ~ 40 60A 32.0 60A<br />

40 ~ ~ ~ ~ ~ ~ 41.0 60A<br />

Single Phase <strong>Motor</strong> Loads ➊➋➌<br />

Horsepower<br />

FLA<br />

115V<br />

Fuse<br />

Block<br />

FLA<br />

230V<br />

Fuse<br />

Block<br />

1/6 4.4 30A 2.2 30A<br />

1/4 5.8 30A 2.9 30A<br />

1/3 7.2 30A 3.6 30A<br />

1/2 9.8 30A 4.9 30A<br />

3/4 13.8 30A 6.9 30A<br />

1 16 30A 8 30A<br />

1-1/2 20 30A 10 30A<br />

2 24 60A 12 30A<br />

3 34 60A 17 30A<br />

5 ~ ~ 28 60A<br />

7-1/2 ~ ~ 40 60A<br />

10 ~ ~ 50 60A<br />

➊ Fuse block size is based on Class J Type time-delay fuses for typical motor<br />

acceleration up to 5 seconds. Limited use of Class CC fuse blocks may be used for<br />

motor loads, contact fuse manufacturer for acceptance.<br />

➋ FLA Data is in accordance with UL-508 Table 42.2 & NEC Tables 430-148 & 150.<br />

➌ Selection of fuse block should be based on selected fuse manufacturer data.<br />

M<br />

<strong>Circuit</strong><br />

Protection<br />

FH7<br />

Discount Schedule B-7<br />

M39


Series FH7 Fuse Holders<br />

Notes Page<br />

Notes<br />

M<br />

<strong>Circuit</strong><br />

Protection<br />

Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />