<strong>KT7</strong> <strong>Motor</strong> <strong>Circuit</strong> <strong>Controllers</strong><br />
<strong>Motor</strong> <strong>Circuit</strong> <strong>Controllers</strong> – General Description ............................................F2<br />
Series KTA7 & KTA3-100 Base Units ..........................................................F4<br />
Series KTC7 Base Units ..............................................................................F6<br />
Series KTB7 Base Units ..............................................................................F8<br />
Accessories ..........................................................................................F10<br />
Type 2 Coordination ..............................................................................F20<br />
Technical Information – <strong>KT7</strong> .................................................................F22<br />
Dimensions – <strong>KT7</strong> ................................................................................F35<br />
Technical Information – KTA3-100 ........................................................F38<br />
Dimensions – KTA3-100 .......................................................................F43<br />
Ecombo and EcomboPlus <strong>Starters</strong> – General Description .....................F44<br />
CL4 / CLU4 Ecombo <strong>Starters</strong> .....................................................................F46<br />
CL7 / CLU7 Ecombo <strong>Starters</strong> .....................................................................F48<br />
CK7 / CKU7 EcomboPlus <strong>Starters</strong> ..............................................................F50<br />
Factory Options .....................................................................................F53<br />
<strong>KT7</strong> Assembly – Application Rating Chart ..............................................F54<br />
Wiring Diagrams ...................................................................................F56<br />
Dimensions ...........................................................................................F57<br />
Enclosed <strong>KT7</strong> <strong>Motor</strong> <strong>Circuit</strong> <strong>Controllers</strong> ..................................................F63<br />
<strong>Manual</strong> Combo .....................................................................................F64<br />
CX7 Combo ...........................................................................................F68<br />
Explosion-proof <strong>KT7</strong> <strong>Motor</strong> <strong>Controllers</strong> ..................................................F73<br />
Dimensions and Technical Info. .............................................................F76<br />
<strong>Motor</strong> Current Rating Chart ...................................................................F80<br />
Methods of Applying <strong>KT7</strong> <strong>Motor</strong> <strong>Circuit</strong> <strong>Controllers</strong> ...............................F81<br />
<strong>KT4</strong> <strong>Manual</strong> <strong>Motor</strong> <strong>Starters</strong><br />
Table of Content .........................................................................................F89<br />
<strong>Manual</strong> <strong>Motor</strong> Staters – General Description ..............................................F90<br />
Quick Selection Guide ................................................................................F91<br />
Accessories ...............................................................................................F92<br />
Explosion Proof <strong>Manual</strong> Starter Type EV3 ..............................................F96<br />
Technical Information .................................................................................F97<br />
Dimensions ..............................................................................................F102<br />
F<br />
<strong>Motor</strong> <strong>Circuit</strong><br />
<strong>Controllers</strong><br />
<strong>KT7</strong><br />
F1
F<br />
<strong>Motor</strong> <strong>Circuit</strong><br />
<strong>Controllers</strong><br />
Series <strong>KT7</strong><br />
<strong>Motor</strong> <strong>Circuit</strong><br />
<strong>Controllers</strong><br />
Versatile, convenient<br />
and space saving…<br />
for a variety of<br />
applications<br />
R<br />
Sprecher+Schuh’s new <strong>KT7</strong> series of<br />
<strong>Motor</strong> <strong>Circuit</strong> <strong>Controllers</strong> are some of<br />
the most versatile and technologically<br />
advanced control products available<br />
today.<br />
In one small package, <strong>KT7</strong>s combine<br />
the functions of:<br />
• Current limiting short circuit<br />
protection<br />
• Class 10 thermal overload<br />
protection<br />
• Switching and<br />
• Signaling<br />
These devices can be used in a<br />
variety of control schemes that<br />
reduce panel space, simplify installation<br />
and eliminate the need for more<br />
expensive equipment.<br />
New models…<br />
Increased ratings…<br />
Sprecher+Schuh’s <strong>KT7</strong> controller family<br />
has been expanded with the introduction<br />
of our new <strong>KT7</strong> line, which<br />
offers higher interrupting capacities<br />
(KAIC ratings), improved Type 2 Coordination<br />
and a midsize frame rated<br />
to 45A (see photo below). In addition,<br />
the line has been expanded to include<br />
a new “high break” 25A device which<br />
offers 65kA of short circuit protection<br />
in applications up to 20 FLA.<br />
Designed for multiple applications<br />
New UL rules allow <strong>KT7</strong> <strong>Motor</strong> <strong>Circuit</strong><br />
<strong>Controllers</strong> to be used in a wide<br />
variety of applications including:<br />
• <strong>Manual</strong> Starter Applications<br />
• Traditional Group <strong>Motor</strong> Applications<br />
with compliance to the new<br />
Tap Conductor Ratings<br />
• <strong>Motor</strong> Disconnect Applications<br />
• Self-Protected <strong>Manual</strong> Combination<br />
Starter Applications (Type E)<br />
• Individual Combination Starter Applications<br />
• Multi-motor Starter Combination<br />
Applications<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />
<strong>KT7</strong><br />
F2<br />
45mm<br />
(≈1 3/4˝)<br />
25A<br />
Standard Interrupting Capacity<br />
45mm<br />
(≈1 3/4˝)<br />
25A<br />
High Interrupting Capacity<br />
54mm<br />
(≈2 1/8˝)<br />
45A<br />
High Interrupting Capacity<br />
80mm<br />
(≈3 5/16˝)<br />
High Interrupting Capacity<br />
90A
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />
Construction Type E Listing<br />
Improved current limiting and breaking<br />
capacity has allowed <strong>KT7</strong>s to<br />
be UL / CSA listed as self-protected<br />
(Construction Type E) manual combination<br />
motor controllers. This eliminates<br />
the need for an upstream fuse or<br />
circuit breaker when using the <strong>KT7</strong> as<br />
a manual motor starter. In addition,<br />
<strong>KT7</strong>s also meet UL requirements for<br />
<strong>KT7</strong>s meet UL requirements for Type E manual<br />
motor controllers and “at-motor disconnects”<br />
Excellent short circuit<br />
protection characteristics<br />
In the event of a short-circuit, the<br />
contacts are opened by magnetic,<br />
non-adjusting tripping elements in<br />
times approaching 3/1000 of a second.<br />
This results in the extremely<br />
rapid buildup of an arc voltage which<br />
limits the current of the short-circuit<br />
to a very low level. Because of this<br />
superb current limiting capability,<br />
KTA <strong>Motor</strong> <strong>Circuit</strong> <strong>Controllers</strong> have<br />
a short circuit capacity of up to 65kA<br />
at 480V and up to 47kA at 600V (see<br />
illustration below).<br />
<strong>Manual</strong> <strong>Motor</strong> Starter Ratings<br />
65kA<br />
<strong>KT7</strong>-25S<br />
<strong>KT7</strong>-25H<br />
“at-motor disconnects,” which means<br />
they can be used in an enclosure with a<br />
lockable handle as a manual motor starter<br />
for individual circuits, and are also an<br />
approved means of motor disconnect.<br />
Type E + Combo starter +<br />
Economy = “Ecombo” starter<br />
When the <strong>KT7</strong> self-protected manual<br />
combination starter is combined with<br />
Sprecher + Schuh’s CA7 contactor to<br />
provide remote operation, we now have<br />
an alternative to the classic combination<br />
starter. We call these “Ecombo” starters,<br />
which save significant dollars and panel<br />
space over conventional combo starters.<br />
Ecombo starters are available for applications<br />
up to 15HP (@460/600V).<br />
25kA<br />
Superb thermal overload<br />
protection<br />
Every <strong>KT7</strong> device is individually calibrated<br />
at the factory for the smallest<br />
and largest current it can handle. When<br />
coupled with automatic ambient temperature<br />
compensation over a range of<br />
-25°C to +60°C, very accurate thermal<br />
overload protection is obtained. In addition,<br />
the <strong>KT7</strong> is a Class 10 device…<br />
it trips within 10 seconds under locked<br />
rotor conditions (6 x FLA). This better<br />
protects today’s T-Frame motors.<br />
30kA<br />
See a complete explanation of<br />
Ecombo starters beginning on page<br />
F40 of this catalog.<br />
65kA<br />
50kA<br />
<strong>KT7</strong>-45H<br />
Special units<br />
for special<br />
applications<br />
KTC7 controllers are available<br />
with a fixed magnetic<br />
trip set at 16…20x the<br />
maximum value of the<br />
current adjustment range<br />
(as opposed to 13x for the<br />
Multi-motor applications…<br />
Popular and money saving<br />
Because of the <strong>KT7</strong>’s new Construction<br />
Type E – UL Rating as a<br />
self-protected combination starter,<br />
many group motor installations can<br />
utilize an even simpler design and less<br />
expensive equipment. The result is<br />
minimum panel size and maximum<br />
flexibility while avoiding cumbersome<br />
NEC group motor rules.<br />
Using <strong>KT7</strong>s in Multi-<strong>Motor</strong> Starter applications<br />
can replace classic Branch <strong>Circuit</strong> Protection<br />
Devices and reduce panel space up to 60%<br />
KTA and KTB7). This prevents nuisance<br />
tripping in applications utilizing<br />
high efficiency motors for example.<br />
The KTB7 model is available without<br />
the thermal trip feature if a separate<br />
motor overload is required.<br />
Other protection features<br />
All <strong>KT7</strong> <strong>Motor</strong> <strong>Circuit</strong> <strong>Controllers</strong><br />
provide accelerated tripping under<br />
single phase conditions. This is accomplished<br />
with a special “differential<br />
tripping” mechanism built into each<br />
device.<br />
All <strong>KT7</strong> <strong>Motor</strong> <strong>Circuit</strong> <strong>Controllers</strong> offer accelerated<br />
tripping under single phase conditions<br />
F<br />
<strong>Motor</strong> <strong>Circuit</strong><br />
<strong>Controllers</strong><br />
<strong>KT7</strong><br />
F3
<strong>Motor</strong> <strong>Circuit</strong> Controller<br />
Series KTA7 / KTA3-100<br />
KTA7 Base Unit<br />
F<br />
<strong>Motor</strong> <strong>Circuit</strong><br />
<strong>Controllers</strong><br />
Typical<br />
Single<br />
Phase<br />
Maximum Horsepower<br />
Typical<br />
Three Phase [HP]<br />
115V 230V 200V 230V 460V 575V<br />
Current<br />
Adjustment<br />
Range [A]<br />
KTA7-25S — Standard Interrupting Capacity<br />
Horsepower ratings shown in the table are for reference only.<br />
The final selection of the manual starter depends on the actual<br />
motor full load current and service factor.<br />
• For motor with service factor less than 1.15. Use motor nameplate full load<br />
current times 0.9 and choose the motor starter with the appropriate current<br />
range. Example: <strong>Motor</strong> F.L.C. = 4.2A; S.F. = 1.0. – 4.2A x 0.9 = 3.78A.<br />
Select Catalog Number KTA7-25S-4.0A.<br />
Magnetic<br />
Release<br />
Response<br />
Current [A] Catalog Number Price<br />
~ ~ ~ ~ ~ ~ 0.10...0.16 2.1 KTA7-25S-0.16A 133<br />
~ ~ ~ ~ ~ ~ 0.16...0.25 3.3 KTA7-25S-0.25A 133<br />
~ ~ ~ ~ ~ ~ 0.25...0.40 5.2 KTA7-25S-0.4A 133<br />
~ ~ ~ ~ ~ ~ 0.40...0.63 8.2 KTA7-25S-0.63A 154<br />
~ ~ ~ ~ 1/2 3/4 0.63...1.0 13 KTA7-25S-1A 154<br />
~ 1/10 ~ ~ 1 1 1.0...1.6 21 KTA7-25S-1.6A 154<br />
1/10 1/6 1/2 3/4 1-1/2 2 1.6...2.5 33 KTA7-25S-2.5A 154<br />
1/8 1/3 1 1 3 3 2.5...4 52 KTA7-25S-4A 154<br />
1/4 3/4 1-1/2 2 5 5 4...6.3 82 KTA7-25S-6.3A 154<br />
1/2 1-1/2 3 3 7-1/2 10 6.3...10 130 KTA7-25S-10A 154<br />
1 3 3 5 10 15 10...16 208 KTA7-25S-16A 176<br />
1-1/2 3 5 7-1/2 15 20 14.5...20 260 KTA7-25S-20A 176<br />
2 3 7-1/2 7-1/2 15 20 18...25 325 KTA7-25S-25A 176<br />
KTA7-25H — High Interrupting Capacity<br />
1/10 1/6 1/2 3/4 1-1/2 2 1.6...2.5 33 KTA7-25H-2.5A 193<br />
1/8 1/3 1 1 3 3 2.5...4 52 KTA7-25H-4A 193<br />
1/4 3/4 1-1/2 2 5 5 4...6.3 82 KTA7-25H-6.3A 193<br />
1/2 1-1/2 3 3 7-1/2 10 6.3...10 130 KTA7-25H-10A 220<br />
1 3 3 5 10 15 10...16 208 KTA7-25H-16A 220<br />
1-1/2 3 5 7-1/2 15 20 14.5...20 260 KTA7-25H-20A 220<br />
2 3 7-1/2 7-1/2 15 20 18...25 325 KTA7-25H-25A 220<br />
KTA7-45H — High Interrupting Capacity<br />
1/2 1-1/2 3 3 7-1/2 10 6.3...10 130 KTA7-45H-10A 309<br />
1 3 3 5 10 15 10...16 208 KTA7-45H-16A 309<br />
1-1/2 3 5 7-1/2 15 20 14.5...20 260 KTA7-45H-20A 309<br />
2 5 5 7-1/2 20 25 18...25 325 KTA7-45H-25A 309<br />
2 5 10 10 25 30 23...32 416 KTA7-45H-32A 347<br />
3 7-1/2 15 15 30 40 32...45 585 KTA7-45H-45A 347<br />
KTA3-100 — High Interrupting Capacity<br />
2 5 1-1/2 10 20 25 16...25 350 KTA3-100-25A 326<br />
3 7-1/2 10 15 30 40 25...40 560 KTA3-100-40A 384<br />
5 10 20 20 50 60 40...63 882 KTA3-100-63A 384<br />
7-1/2 20 30 30 60 75 63...90 1260 KTA3-100-90A 420<br />
Catalog Number KTA7-25S<br />
Catalog Number KTA7-25H<br />
Catalog Number KTA7-45H<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />
<strong>KT7</strong><br />
F4<br />
Discount Schedule A-1
<strong>Motor</strong> <strong>Circuit</strong> Controller<br />
Series KTA7 / KTA3-100<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />
KTA7 UL Ratings Application Chart<br />
<strong>Manual</strong> <strong>Motor</strong><br />
Starter<br />
Max. Short <strong>Circuit</strong><br />
Current [kA]<br />
<strong>Manual</strong> Controller for Group<br />
Installation ➊<br />
Max. Fuse<br />
or <strong>Circuit</strong><br />
Breaker<br />
Max. Short <strong>Circuit</strong><br />
Current [kA]<br />
➊ UL 508, CSA 22.2 No. 14 for group installation, in connection with short-circuit<br />
protection device.<br />
➋ UL 508 Part III.<br />
➌ UL 508 Part IV.<br />
➍ Type E applications require use of the <strong>KT7</strong>-xx-TE terminal adaptor on <strong>KT7</strong>s<br />
produced after July 16, 2001.<br />
➎ Requires lockable twist knob (<strong>KT7</strong>-KN or <strong>KT7</strong>-KRY) or lockable door coupling<br />
handle (<strong>KT7</strong>-HTN or <strong>KT7</strong>-HTRY). See page F14.<br />
<strong>Manual</strong> Controller<br />
as <strong>Motor</strong><br />
Disconnect ➋➎<br />
Max. Short <strong>Circuit</strong><br />
Current [kA]<br />
Suitable for Tap<br />
Conductor Protection<br />
Max. Short <strong>Circuit</strong><br />
Current [kA]<br />
Self-Protected Type E<br />
<strong>Manual</strong> Combination<br />
Controller ➌➍➎<br />
Max. Short <strong>Circuit</strong><br />
Current [kA]<br />
Device<br />
480V 600V 480V 600V 480V 600V 480Y/277V 600Y/347V 480Y/277V 600Y/347V<br />
KTA7-25S — Standard Interrupting Capacity<br />
KTA7-25S-0.16A 65 47 450 65 47 65 47 65 47 65 47<br />
KTA7-25S-0.25A 65 47 450 65 47 65 47 65 47 65 47<br />
KTA7-25S-0.4A 65 47 450 65 47 65 47 65 47 65 47<br />
KTA7-25S-0.63A 65 47 450 65 47 65 47 65 47 65 47<br />
KTA7-25S-1A 65 47 450 65 47 65 47 65 47 65 47<br />
KTA7-25S-1.6A 65 47 450 65 47 65 47 65 47 65 47<br />
KTA7-25S-2.5A 65 30 450 65 30 65 30 65 30 65 30<br />
KTA7-25S-4A 65 25 450 65 25 65 25 65 25 65 25<br />
KTA7-25S-6.3A 65 30 450 65 30 65 30 65 ~ 65 ~<br />
KTA7-25S-10A 65 30 450 65 30 65 30 65 ~ 65 ~<br />
KTA7-25S-16A 30 30 450 30 30 30 30 30 ~ 30 ~<br />
KTA7-25S-20A 30 30 450 30 30 10 10 10 ~ 10 ~<br />
KTA7-25S-25A 25 10 450 25 10 10 5 ~ ~ ~ ~<br />
KTA7-25H — High Interrupting Capacity<br />
KTA7-25H-2.5A 65 30 450 65 30 65 30 65 30 65 30<br />
KTA7-25H-4A 65 30 450 65 30 65 30 65 30 65 30<br />
KTA7-25H-6.3A 65 30 450 65 30 65 30 65 30 65 30<br />
KTA7-25H-10A 65 30 450 65 30 65 30 65 30 65 30<br />
KTA7-25H-16A 65 30 450 65 30 65 30 65 30 65 30<br />
KTA7-25H-20A 65 30 450 65 30 65 30 65 ~ 65 ~<br />
KTA7-25H-25A 30 30 450 30 30 30 30 30 ~ 30 ~<br />
KTA7-45H — High Interrupting Capacity<br />
KTA7-45H-10A 65 30 600 65 30 65 30 65 30 65 30<br />
KTA7-45H-16A 65 30 600 65 30 65 30 65 30 65 30<br />
KTA7-45H-20A 65 30 600 65 30 65 30 65 30 65 30<br />
KTA7-45H-25A 65 30 600 65 30 65 30 65 30 65 30<br />
KTA7-45H-32A 65 30 600 65 30 65 30 65 30 65 30<br />
KTA7-45H-45A 65 18 600 65 18 65 18 65 ~ 65 ~<br />
KTA3-100 — High Interrupting Capacity<br />
KTA3-100-25A 65 42 1000 65 42 ~ ~ ~ ~ ~ ~<br />
KTA3-100-40A 65 42 1000 65 42 ~ ~ ~ ~ ~ ~<br />
KTA3-100-63A 42 18 1000 42 18 ~ ~ ~ ~ ~ ~<br />
KTA3-100-90A 35 10 1000 35 10 ~ ~ ~ ~ ~ ~<br />
It should be noted that the <strong>KT7</strong> <strong>Manual</strong> <strong>Motor</strong> <strong>Circuit</strong> Controller, when listed as a<br />
self-protected (Type E) device, is rated for Wye-connected power systems for<br />
voltages above 240 volts (i.e. 480Y / 277 volts common in the United States or<br />
600Y/ 347 volts common in Canada).<br />
F<br />
<strong>Motor</strong> <strong>Circuit</strong><br />
<strong>Controllers</strong><br />
<strong>KT7</strong><br />
Discount Schedule A-1<br />
F5
<strong>Motor</strong> <strong>Circuit</strong> Controller<br />
Series KTC7<br />
KTC7 Base Unit<br />
F<br />
<strong>Motor</strong> <strong>Circuit</strong><br />
<strong>Controllers</strong><br />
Typical<br />
Single<br />
Phase<br />
Maximum Horsepower<br />
Typical<br />
Three Phase [HP]<br />
Current<br />
Adjustment<br />
Range [A]<br />
Horsepower ratings shown in the table are for reference only.<br />
The final selection of the manual starter depends on the actual<br />
motor full load current and service factor.<br />
• For motor with service factor less than 1.15. Use motor nameplate full load<br />
current times 0.9 and choose the motor starter with the appropriate current<br />
range. Example: <strong>Motor</strong> F.L.C. = 4.2A; S.F. = 1.0. – 4.2A x 0.9 = 3.78A.<br />
Select Catalog Number KTA7-25S-4.0A.<br />
Magnetic<br />
Release<br />
Response<br />
Current [A] Catalog Number Price<br />
115V 230V 200V 230V 460V 575V<br />
KTC7-25S — Standard Interrupting Capacity<br />
~ ~ ~ ~ ~ ~ 0.10...0.16 3.3 KTC7-25S-0.16A 133<br />
~ ~ ~ ~ ~ ~ 0.16...0.25 5.2 KTC7-25S-0.25A 133<br />
~ ~ ~ ~ ~ ~ 0.25...0.40 8.2 KTC7-25S-0.4A 133<br />
~ ~ ~ ~ ~ ~ 0.40...0.63 13 KTC7-25S-0.63A 154<br />
~ ~ ~ ~ 1/2 3/4 0.63...1.0 21 KTC7-25S-1A 154<br />
~ 1/10 ~ ~ 1 1 1.0...1.6 33 KTC7-25S-1.6A 154<br />
1/10 1/6 1/2 3/4 1-1/2 2 1.6...2.5 52 KTC7-25S-2.5A 154<br />
1/8 1/3 1 1 3 3 2.5...4 82 KTC7-25S-4A 154<br />
1/4 3/4 1-1/2 2 5 5 4...6.3 130 KTC7-25S-6.3A 154<br />
1/2 1-1/2 3 3 7-1/2 10 6.3...10 208 KTC7-25S-10A 154<br />
1 3 3 5 10 15 10...16 260 KTC7-25S-16A 176<br />
KTC7-25H — High Interrupting Capacity<br />
1 3 3 5 10 15 10...16 260 KTC7-25H-16A 220<br />
1-1/2 3 5 7-1/2 15 20 14.5...20 325 KTC7-25H-20A 220<br />
KTC7-45H — High Interrupting Capacity<br />
2 5 5 7-1/2 20 25 18...25 416 KTC7-45H-25A 309<br />
2 5 10 10 25 30 23...32 585 KTC7-45H-32A 347<br />
KTC7-25S<br />
Description<br />
The KTC7 has a fixed magnetic trip set<br />
at 16…20x the maximum value of the<br />
current adjustment range (as opposed<br />
to the KTA7s magnetic trip of<br />
approximately 13x current adjustment<br />
range). KTC7 are typically used in<br />
applications where nuisance tripping<br />
might occur, as with some high<br />
efficiency motors.<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />
<strong>KT7</strong><br />
➊ Magnetic trip is fixed at 16…20x the maximum value of the current adjustment range.<br />
F6<br />
Discount Schedule A-1
<strong>Motor</strong> <strong>Circuit</strong> Controller<br />
Series KTC7<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />
KTC7 UL Ratings Application Chart<br />
<strong>Manual</strong> <strong>Motor</strong><br />
Starter<br />
Max. Short <strong>Circuit</strong><br />
Current [kA]<br />
<strong>Manual</strong> Controller for Group<br />
Installation ➊<br />
Max. Fuse<br />
or <strong>Circuit</strong><br />
Breaker<br />
Max. Short <strong>Circuit</strong><br />
Current [kA]<br />
➊ UL 508, CSA 22.2 No. 14 for group installation, in connection with short-circuit<br />
protection device.<br />
➋ UL 508 Part III.<br />
➌ UL 508 Part IV.<br />
➍ Type E applications require use of the <strong>KT7</strong>-xx-TE terminal adaptor on <strong>KT7</strong>s<br />
produced after July 16, 2001.<br />
➎ Requires lockable twist knob (<strong>KT7</strong>-KN or <strong>KT7</strong>-KRY) or lockable door coupling<br />
handle (<strong>KT7</strong>-HTN or <strong>KT7</strong>-HTRY). See page F14.<br />
<strong>Manual</strong> Controller<br />
as <strong>Motor</strong><br />
Disconnect ➋➎<br />
Max. Short <strong>Circuit</strong><br />
Current [kA]<br />
Suitable for Tap<br />
Conductor Protection<br />
Max. Short <strong>Circuit</strong><br />
Current [kA]<br />
Self-Protected Type E<br />
<strong>Manual</strong> Combination<br />
Controller ➌➍➎<br />
Max. Short <strong>Circuit</strong><br />
Current [kA]<br />
Device<br />
480V 600V 480V 600V 480V 600V 480Y/277V 600Y/347V 480Y/277V 600Y/347V<br />
KTC7-25S — Standard Interrupting Capacity<br />
KTC7-25S-0.16A 65 47 450 65 47 65 47 65 47 65 47<br />
KTC7-25S-0.25A 65 47 450 65 47 65 47 65 47 65 47<br />
KTC7-25S-0.4A 65 47 450 65 47 65 47 65 47 65 47<br />
KTC7-25S-0.63A 65 47 450 65 47 65 47 65 47 65 47<br />
KTC7-25S-1A 65 47 450 65 47 65 47 65 47 65 47<br />
KTC7-25S-1.6A 65 47 450 65 47 65 47 65 47 65 47<br />
KTC7-25S-2.5A 65 25 450 65 25 65 25 65 30 65 30<br />
KTC7-25S-4A 65 30 450 65 30 65 30 65 25 65 25<br />
KTC7-25S-6.3A 65 30 450 65 30 65 30 65 ~ 65 ~<br />
KTC7-25S-10A 30 30 450 30 30 30 30 30 ~ 30 ~<br />
KTC7-25S-16A 30 30 450 30 30 10 10 10 ~ 10 ~<br />
KTC7-25H — High Interrupting Capacity<br />
KTC7-25H-16A 65 30 450 65 30 65 30 65 30 65 30<br />
KTC7-25H-20A 30 30 450 30 30 65 30 30 ~ 30 ~<br />
KTC7-45H — High Interrupting Capacity<br />
KTC7-45H-25A 65 30 600 65 30 65 30 65 30 65 30<br />
KTC7-45H-32A 65 18 600 65 18 65 18 65 18 65 18<br />
It should be noted that the <strong>KT7</strong> <strong>Manual</strong> <strong>Motor</strong> <strong>Circuit</strong> Controller, when listed as a<br />
self-protected (Type E) device, is rated for Wye-connected power systems for<br />
voltages above 240 volts (i.e. 480Y / 277 volts common in the United States or<br />
600Y/ 347 volts common in Canada).<br />
F<br />
<strong>Motor</strong> <strong>Circuit</strong><br />
<strong>Controllers</strong><br />
<strong>KT7</strong><br />
Discount Schedule A-1<br />
F7
<strong>Motor</strong> <strong>Circuit</strong> Controller<br />
Series KTB7<br />
KTB7 Base Unit<br />
F<br />
<strong>Motor</strong> <strong>Circuit</strong><br />
<strong>Controllers</strong><br />
Typical<br />
Single<br />
Phase<br />
Maximum Horsepower<br />
Typical<br />
Three Phase [HP]<br />
Current<br />
Adjustment<br />
Range [A]<br />
Horsepower ratings shown in the table are for reference only.<br />
The final selection of the manual starter depends on the actual<br />
motor full load current and service factor.<br />
• For motor with service factor less than 1.15. Use motor nameplate full load<br />
current times 0.9 and choose the motor starter with the appropriate current<br />
range. Example: <strong>Motor</strong> F.L.C. = 4.2A; S.F. = 1.0. – (4.2A x 0.9 = 3.78A).<br />
Select Catalog Number KTA7-25S-4.0A.<br />
Magnetic<br />
Release<br />
Response<br />
Current [A] Catalog Number Price<br />
115V 230V 200V 230V 460V 575V<br />
KTB7-25S — Standard Interrupting Capacity<br />
~ ~ ~ ~ ~ ~ 0.16 3.3 KTB7-25S-0.16A 133<br />
~ ~ ~ ~ ~ ~ 0.25 5.2 KTB7-25S-0.25A 133<br />
~ ~ ~ ~ ~ ~ 0.40 8.2 KTB7-25S-0.4A 133<br />
~ ~ ~ ~ ~ ~ 0.63 13 KTB7-25S-0.63A 154<br />
~ ~ ~ ~ 1/2 3/4 1.0 21 KTB7-25S-1A 154<br />
~ 1/10 ~ ~ 1 1 1.6 33 KTB7-25S-1.6A 154<br />
1/10 1/6 1/2 3/4 1-1/2 2 2.5 52 KTB7-25S-2.5A 154<br />
KTB7-25H — High Interrupting Capacity<br />
1/10 1/6 1/2 3/4 1-1/2 2 2.5 33 KTB7-25H-2.5A 193<br />
1/4 3/4 1-1/2 2 5 5 4 52 KTB7-25H-4A 193<br />
1/2 1-1/2 3 3 7-1/2 10 6.3 82 KTB7-25H-6.3A 193<br />
1 3 3 5 10 15 10 130 KTB7-25H-10A 220<br />
1-1/2 3 5 7-1/2 15 20 16 208 KTB7-25H-16A 220<br />
2 3 7-1/2 7-1/2 15 20 25 325 KTB7-25H-25A 220<br />
KTB7-45H — High Interrupting Capacity<br />
2 5 5 7-1/2 20 25 25 325 KTB7-45H-25A 309<br />
2 5 10 10 25 30 32 416 KTB7-45H-32A 347<br />
3 7-1/2 15 15 30 40 45 585 KTB7-45H-45A 347<br />
KTB7-25S<br />
Description<br />
The KTB7 is designed without a<br />
thermal trip element (i.e., current<br />
adjustment range). It should be<br />
selected for applications where a<br />
separate motor overload protection<br />
device is used. Magnetic trip is the<br />
same as the KTA7 (approximately 13x<br />
operational current).<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />
<strong>KT7</strong><br />
F8<br />
Discount Schedule A-1
<strong>Motor</strong> <strong>Circuit</strong> Controller<br />
Series KTB7<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />
KTB7 UL Ratings Application Chart<br />
Device<br />
<strong>Manual</strong> <strong>Motor</strong><br />
Starter<br />
Max. Short <strong>Circuit</strong><br />
Current [kA]<br />
<strong>Manual</strong> Controller for Group<br />
Installation ➊<br />
Max. Fuse<br />
or <strong>Circuit</strong><br />
Breaker<br />
Max. Short <strong>Circuit</strong><br />
Current [kA]<br />
➊ UL 508, CSA 22.2 No. 14 for group installation, in connection with short-circuit<br />
protection device.<br />
➋ UL 508 Part III.<br />
<strong>Manual</strong> Controller<br />
as <strong>Motor</strong><br />
Disconnect ➋<br />
Max. Short <strong>Circuit</strong><br />
Current [kA]<br />
480V 600V 480V 600V 480V 600V<br />
KTA7-25S — Standard Interrupting Capacity<br />
KTB7-25S-0.16A 65 47 450 65 47 65 47<br />
KTB7-25S-0.25A 65 47 450 65 47 65 47<br />
KTB7-25S-0.4A 65 47 450 65 47 65 47<br />
KTB7-25S-0.63A 65 47 450 65 47 65 47<br />
KTB7-25S-1A 65 47 450 65 47 65 47<br />
KTB7-25S-1.6A 65 47 450 65 47 65 47<br />
KTB7-25S-2.5A 65 30 450 65 30 65 30<br />
KTA7-25H — High Interrupting Capacity<br />
KTB7-25H-2.5A 65 30 450 65 30 65 30<br />
KTB7-25H-4A 65 30 450 65 30 65 30<br />
KTB7-25H-6.3A 65 30 450 65 30 65 30<br />
KTB7-25H-10A 65 30 450 65 30 65 30<br />
KTB7-25H-16A 65 30 450 65 30 65 30<br />
KTB7-25H-25A 30 30 450 30 30 30 30<br />
KTA7-45H — High Interrupting Capacity<br />
KTB7-45H-25A 65 30 600 65 30 65 30<br />
KTB7-45H-32A 65 30 600 65 30 65 30<br />
KTB7-45H-45A 65 18 600 65 18 65 18<br />
F<br />
<strong>Motor</strong> <strong>Circuit</strong><br />
<strong>Controllers</strong><br />
<strong>KT7</strong><br />
Discount Schedule A-1<br />
F9
Accessories<br />
Series <strong>KT7</strong><br />
Accessories for <strong>KT7</strong><br />
F<br />
<strong>Motor</strong> <strong>Circuit</strong><br />
<strong>Controllers</strong><br />
➊ X=Contact Closed<br />
O=Contact Open<br />
➋<br />
Accessory<br />
Description<br />
Front-Mounted<br />
Auxiliary Contact<br />
• 1-pole or 2-pole<br />
• No additional<br />
space required<br />
Right<br />
Side-Mounted<br />
Auxiliary Contact<br />
• 2-pole<br />
• Adds 9 mm to<br />
the width of the<br />
device<br />
Operator Position ➊<br />
OFF ON Tripped<br />
Type<br />
Connection Diagram and<br />
Terminal Markings ➋<br />
For Use<br />
With Catalog Number Price<br />
O X O 1 NO All <strong>KT7</strong>s <strong>KT7</strong>-PE1-10 16<br />
X O X 1 NC All <strong>KT7</strong>s <strong>KT7</strong>-PE1-01 13<br />
O X O 1 NO<br />
X O X 1 NC<br />
O X O 1 NO<br />
O X O 1 NO<br />
X O X 1 NC<br />
X O X 1 NC<br />
O X O 1 NO<br />
O X O 1 NO<br />
X O X 1 NC<br />
X O X 1 NC<br />
O X O 1 NO<br />
X O X 1 NC<br />
All <strong>KT7</strong>s <strong>KT7</strong>-PE1-11 19<br />
All <strong>KT7</strong>s <strong>KT7</strong>-PE1-20 19<br />
All <strong>KT7</strong>s <strong>KT7</strong>-PE1-02 19<br />
All <strong>KT7</strong>s <strong>KT7</strong>-PA1-20 29<br />
All <strong>KT7</strong>s <strong>KT7</strong>-PA1-02 29<br />
All <strong>KT7</strong>s <strong>KT7</strong>-PA1-11 29<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />
<strong>KT7</strong><br />
F10<br />
Discount Schedule A-1
Accessories<br />
Series <strong>KT7</strong><br />
Accessories for <strong>KT7</strong><br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />
➊ X=Contact Closed<br />
O=Contact Open<br />
➋<br />
Accessory<br />
Description<br />
Front-Mounted<br />
Trip Contact<br />
• 2-pole<br />
• Indicates<br />
tripping of<br />
device<br />
• No additional<br />
space required<br />
Right<br />
Side-Mounted<br />
Trip Contact<br />
• 2-pole<br />
• Indicates<br />
tripping of<br />
motor protector<br />
• Adds 9 mm to<br />
the width of the<br />
device<br />
Operator Position ➊<br />
OFF ON Tripped<br />
Type<br />
O X O 1 NO<br />
O O X<br />
NO Trip<br />
(Short-<strong>Circuit</strong> &<br />
Overload)<br />
X O X 1 NC<br />
O O X<br />
O O X<br />
O O X<br />
O O X<br />
X X O<br />
X X O<br />
O O X<br />
X X O<br />
X X O<br />
O O X<br />
X X O<br />
NO Trip<br />
(Short-<strong>Circuit</strong> &<br />
Overload)<br />
NO Trip<br />
(Short-<strong>Circuit</strong> &<br />
Overload)<br />
NO Trip<br />
(Short-<strong>Circuit</strong>)<br />
NO Trip<br />
(Short-<strong>Circuit</strong> &<br />
Overload)<br />
NC Trip<br />
(Short-<strong>Circuit</strong>)<br />
NC Trip<br />
(Short-<strong>Circuit</strong> &<br />
Overload)<br />
NO Trip<br />
(Short-<strong>Circuit</strong>)<br />
NC Trip<br />
(Short-<strong>Circuit</strong> &<br />
Overload)<br />
NC Trip<br />
(Short-<strong>Circuit</strong>)<br />
NO Trip<br />
(Short-<strong>Circuit</strong>)<br />
NC Trip<br />
(Short-<strong>Circuit</strong>)<br />
Connection Diagram and<br />
Terminal Markings ➋<br />
For Use<br />
With Catalog Number Price<br />
All <strong>KT7</strong>s <strong>KT7</strong>-PEF1-S10/N10 29<br />
All <strong>KT7</strong>s <strong>KT7</strong>-PEF1-S10/N01 29<br />
All <strong>KT7</strong>s <strong>KT7</strong>-PAF1-S10/M10 38<br />
All <strong>KT7</strong>s <strong>KT7</strong>-PAF1-S10/M01 38<br />
All <strong>KT7</strong>s <strong>KT7</strong>-PAF1-S01/M10 38<br />
All <strong>KT7</strong>s <strong>KT7</strong>-PAF1-S01/M01 38<br />
All <strong>KT7</strong>s <strong>KT7</strong>-PAF1-M11 38<br />
F<br />
<strong>Motor</strong> <strong>Circuit</strong><br />
<strong>Controllers</strong><br />
<strong>KT7</strong><br />
Discount Schedule A-1<br />
F11
Accessories<br />
Series KT3-100<br />
Accessories for KTA3-100<br />
F<br />
<strong>Motor</strong> <strong>Circuit</strong><br />
<strong>Controllers</strong><br />
Accessory<br />
➊ X=Contact Closed<br />
O=Contact Open<br />
➋<br />
Description<br />
Front-Mounted<br />
Auxiliary Contact<br />
• Internal<br />
• 2-pole<br />
Front Mounted<br />
Trip Indicating<br />
Auxiliary Contact<br />
• Internal<br />
• 2-pole<br />
Operator Position<br />
OFF ON Tripped<br />
Type<br />
O X O NO<br />
O X O NO<br />
X O X NC<br />
X O X NC<br />
O O X NO<br />
X O X NC<br />
O O X<br />
O O X<br />
X X O<br />
X X O<br />
X X O<br />
O O X<br />
O O X<br />
X X O<br />
NO Trip<br />
(Overload)<br />
NO Trip<br />
(Short-<strong>Circuit</strong>)<br />
NC Trip<br />
(Overload)<br />
NC Trip<br />
(Short-<strong>Circuit</strong>)<br />
NC Trip<br />
(Overload)<br />
NO Trip<br />
(Short-<strong>Circuit</strong>)<br />
NO Trip<br />
(Overload)<br />
NC Trip<br />
(Short-<strong>Circuit</strong>)<br />
Connection Diagram and<br />
Terminal Markings ➋<br />
For Use<br />
With Catalog Number Price<br />
KT3-100 KT3-100-PE-20 20<br />
KT3-100 KT3-100-PE-02 20<br />
KT3-100 KT3-100-PE-11 20<br />
KT3-100 KT3-100-PF-20 38<br />
KT3-100 KT3-100-PF-02 38<br />
KT3-100 KT3-100-PF1-11 38<br />
KT3-100 KT3-100-PF2-11 38<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />
<strong>KT7</strong><br />
F12<br />
Discount Schedule A-1
Accessories<br />
Series KTA3-100<br />
Accessories for KTA3-100<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />
Accessory<br />
Description<br />
Undervoltage Trip<br />
• Internal, front mounted<br />
• Integrated short-circuit trip<br />
integration<br />
• Automatically trips motor<br />
protector when voltage falls<br />
below 35…70%<br />
Shunt Trip Unit<br />
• Internal, front mounted<br />
• Integrated short-circuit trip<br />
integration<br />
• Trips motor protector when<br />
voltage is applied remotely<br />
Connection<br />
Diagram ➊<br />
◗<br />
For Use<br />
With<br />
KTA3-100<br />
KTA3-100<br />
AC Coil Voltage<br />
50 HZ 60 HZ<br />
➊<br />
Catalog Number<br />
24V 28V KT3-100-UA-28V<br />
110V 127V KT3-100-UA-127V<br />
220...230V ~ KT3-100-UA-230V<br />
240V 277V KT3-100-UA-277V<br />
380V 400V KT3-100-UA-400V<br />
415V 480V KT3-100-UA-480V<br />
500V 575V KT3-100-UA-575V<br />
24V 28V KT3-100-<strong>AA</strong>-28V<br />
110V 127V KT3-100-<strong>AA</strong>-127V<br />
220...230V ~ KT3-100-<strong>AA</strong>-230V<br />
240V 277V KT3-100-<strong>AA</strong>-277V<br />
380V 450V KT3-100-<strong>AA</strong>-450V<br />
415V 480V KT3-100-<strong>AA</strong>-480V<br />
500V 575V KT3-100-<strong>AA</strong>-575V<br />
Price<br />
62<br />
62<br />
F<br />
<strong>Motor</strong> <strong>Circuit</strong><br />
<strong>Controllers</strong><br />
➊ Special order on these items.<br />
KTA3<br />
Discount Schedule A-1<br />
F13
Accessories<br />
Series <strong>KT7</strong><br />
Accessories for <strong>KT7</strong><br />
F<br />
<strong>Motor</strong> <strong>Circuit</strong><br />
<strong>Controllers</strong><br />
➊<br />
Accessory<br />
Description<br />
Undervoltage Trip<br />
• Left-side mounted<br />
• Adds 18 mm to the width<br />
of the <strong>KT7</strong> device<br />
• Automatically trips motor<br />
protector when voltage<br />
falls below 35…70%<br />
Connection<br />
Diagram ➊<br />
For Use<br />
With<br />
All <strong>KT7</strong>s<br />
AC Coil Voltage<br />
50 HZ 60 HZ Catalog Number<br />
12V 14V <strong>KT7</strong>-UA-14V<br />
21V 24V <strong>KT7</strong>-UA-24V<br />
24V 28V <strong>KT7</strong>-UA-28V<br />
42V 48V <strong>KT7</strong>-UA-48V<br />
105V 120V <strong>KT7</strong>-UA-120V<br />
110V 127V <strong>KT7</strong>-UA-127V<br />
220...230V<br />
<strong>KT7</strong>-UA-230V<br />
240...260V <strong>KT7</strong>-UA-240V<br />
240V 277V <strong>KT7</strong>-UA-277V<br />
380V 460V <strong>KT7</strong>-UA-460V<br />
415V 480V <strong>KT7</strong>-UA-480V<br />
520V 600V <strong>KT7</strong>-UA-600V<br />
Price<br />
For Use<br />
With DC Coil Voltage Catalog Number Price<br />
9V DC<br />
<strong>KT7</strong>-UA-9D<br />
12V DC<br />
<strong>KT7</strong>-UA-12D<br />
24V DC<br />
<strong>KT7</strong>-UA-24D<br />
36V DC<br />
<strong>KT7</strong>-UA-36D<br />
All <strong>KT7</strong>s<br />
48V DC<br />
<strong>KT7</strong>-UA-48D<br />
68<br />
60V DC<br />
<strong>KT7</strong>-UA-60D<br />
64V DC<br />
<strong>KT7</strong>-UA-64D<br />
72V DC<br />
<strong>KT7</strong>-UA-72D<br />
80V DC<br />
<strong>KT7</strong>-UA-80D<br />
68<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />
<strong>KT7</strong><br />
F14<br />
Discount Schedule A-1
Accessories<br />
Series <strong>KT7</strong><br />
Accessories for <strong>KT7</strong><br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />
➊<br />
Accessory<br />
Description<br />
Shunt Trip<br />
• Left-side mounted<br />
• Adds 18 mm to the width of<br />
the <strong>KT7</strong> device<br />
• Trips motor protector when<br />
voltage is applied remotely<br />
Connection<br />
Diagram ➊<br />
For Use<br />
With<br />
All <strong>KT7</strong>s<br />
AC Coil Voltage<br />
50 HZ 60 HZ Catalog Number<br />
12V 14V <strong>KT7</strong>-<strong>AA</strong>-14V<br />
21V 24V <strong>KT7</strong>-<strong>AA</strong>-24V<br />
24V 28V <strong>KT7</strong>-<strong>AA</strong>-28V<br />
42V 48V <strong>KT7</strong>-<strong>AA</strong>-48V<br />
105V 120V <strong>KT7</strong>-<strong>AA</strong>-120V<br />
110V 127V <strong>KT7</strong>-<strong>AA</strong>-127V<br />
220...230V<br />
<strong>KT7</strong>-<strong>AA</strong>-230V<br />
240...260V <strong>KT7</strong>-<strong>AA</strong>-260V<br />
240V 277V <strong>KT7</strong>-<strong>AA</strong>-277V<br />
380V 460V <strong>KT7</strong>-<strong>AA</strong>-460V<br />
415V 480V <strong>KT7</strong>-<strong>AA</strong>-480V<br />
520V 600V <strong>KT7</strong>-<strong>AA</strong>-600V<br />
Price<br />
For Use<br />
With DC Coil Voltage Catalog Number Price<br />
9V DC<br />
<strong>KT7</strong>-<strong>AA</strong>-9D<br />
12V DC<br />
<strong>KT7</strong>-<strong>AA</strong>-12D<br />
24V DC<br />
<strong>KT7</strong>-<strong>AA</strong>-24D<br />
36V DC<br />
<strong>KT7</strong>-<strong>AA</strong>-36D<br />
48V DC<br />
<strong>KT7</strong>-<strong>AA</strong>-48D<br />
60V DC<br />
<strong>KT7</strong>-<strong>AA</strong>-60D<br />
64V DC<br />
<strong>KT7</strong>-<strong>AA</strong>-64D<br />
All <strong>KT7</strong>s<br />
72V DC<br />
<strong>KT7</strong>-<strong>AA</strong>-72D<br />
68<br />
80V DC<br />
<strong>KT7</strong>-<strong>AA</strong>-80D<br />
110V DC <strong>KT7</strong>-<strong>AA</strong>-110D<br />
115V DC <strong>KT7</strong>-<strong>AA</strong>-115D<br />
125V DC <strong>KT7</strong>-<strong>AA</strong>-125D<br />
220V DC <strong>KT7</strong>-<strong>AA</strong>-220D<br />
230V DC <strong>KT7</strong>-<strong>AA</strong>-230D<br />
250V DC <strong>KT7</strong>-<strong>AA</strong>-250D<br />
68<br />
F<br />
<strong>Motor</strong> <strong>Circuit</strong><br />
<strong>Controllers</strong><br />
<strong>KT7</strong><br />
Discount Schedule A-1<br />
F15
Accessories<br />
Series <strong>KT7</strong> & KT3-100<br />
F<br />
<strong>Motor</strong> <strong>Circuit</strong><br />
<strong>Controllers</strong><br />
<strong>KT7</strong><br />
Accessories for <strong>KT7</strong> and KTA3<br />
Accessory Description Color For Use With<br />
Lockable Twist Knob<br />
• For 1 padlock 4...8 mm (5/16”) dia. shackle<br />
• Can be locked in OFF position<br />
Padlockable Operating Knob<br />
• Accepts 8 mm (5/16”) padlock — Up to three padlocks<br />
• Permits padlocking in the OFF position<br />
Door Coupling Handle ➊<br />
• For 3 padlocks 4...8 mm (5/16”) in diameter<br />
• NEMA Type 3 / 3R / 4 / 4X / 12 and IP66 Protection<br />
• Interlock override capability<br />
• Can be modified for locking in ON position<br />
• Ships with coupling — order extension shaft and legend<br />
plate separately<br />
• See Technical Section for mounting depth information<br />
Extension Shaft<br />
• Cut to required length for mounting depth (adapter-door)<br />
• See Technical Section for mounting depth information<br />
Terminal Adapter for Type E Applications ➋<br />
• Required on all <strong>KT7</strong>s used in UL Type E applications<br />
• May not be used with Bus Bars<br />
Legend Plate<br />
• Marking: “Haupschalter” and “Main Switch” (Black/Gray)<br />
• Marking: “Not-Aus” and “Emergency Off” (Black/Yellow)<br />
Locking Tag<br />
• Padlock attachment to the lockable handles<br />
• Up to three padlocks 4...8 mm (5/16”) shackle<br />
Anti-Tamper Shield<br />
• Provides protection against inadvertent adjustment of the<br />
current setting<br />
• 10 pieces per package (price per piece)<br />
Screw Adaptor<br />
• For screw fixing of <strong>KT7</strong> <strong>Motor</strong> <strong>Circuit</strong> Controller<br />
• 10 pieces per package (price per piece)<br />
➊ Door Coupling Handles [Cat.# KT3-100-HTN or KT3-100-HTRY] are available for<br />
KTA3-100 when used in manual motor starter applications. KTA3-100 is not rated<br />
as a UL Type E disconnect. Contact your Sprecher + Schuh representative.<br />
➋ Terminal Adaptors are supplied as standard on enclosed <strong>KT7</strong> and CX7 starters, as<br />
well as, CL4, CL7 and CK7 assembled products, assuring they can be used in<br />
Type E applications.<br />
Catalog<br />
Number<br />
Price<br />
Black All <strong>KT7</strong>s <strong>KT7</strong>-KN 6<br />
Red/Yellow<br />
<strong>KT7</strong>-25<br />
<strong>KT7</strong>-45<br />
<strong>KT7</strong>-KRY<br />
<strong>KT7</strong>-45-KRY<br />
Black KTA3-100 KT3-100-KN 16<br />
Red/Yellow KTA3-100 KT3-100-KRY 16<br />
Gray/Black All <strong>KT7</strong>s ➊ <strong>KT7</strong>-HTN 71<br />
Red/Yellow All <strong>KT7</strong>s ➊ <strong>KT7</strong>-HTRY 86<br />
<strong>KT7</strong>-HTN<br />
<strong>KT7</strong>-HTRY<br />
KTA3-100-HTN<br />
KTA3-100-HTRY<br />
All <strong>KT7</strong>-25<br />
All <strong>KT7</strong>-45<br />
<strong>KT7</strong>-HTN<br />
<strong>KT7</strong>-HTRY<br />
<strong>KT7</strong>-KN<br />
<strong>KT7</strong>-KRY<br />
<strong>KT7</strong>-45-KRY<br />
9<br />
<strong>KT7</strong>-HT 14<br />
<strong>KT7</strong>-25-TE<br />
<strong>KT7</strong>-45-TE<br />
<strong>KT7</strong>-HTFCN<br />
<strong>KT7</strong>-HTFCRY<br />
5<br />
5<br />
5<br />
5<br />
<strong>KT7</strong>-DS 23<br />
<strong>KT7</strong>-25 <strong>KT7</strong>-25-CA 19<br />
<strong>KT7</strong>-25<br />
<strong>KT7</strong>-45<br />
<strong>KT7</strong>-45-AS 10<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />
F16<br />
Discount Schedule A-1
Accessories<br />
Series KF7<br />
Connecting Modules (for connecting <strong>KT7</strong> to CA4 contactors or CA7 AC coil contactors) ➊<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />
Module<br />
Connecting Modules (for connecting <strong>KT7</strong> to CA7 two winding DC coil contactors)<br />
Module<br />
Mounting Modules<br />
Module<br />
<strong>KT7</strong>-25S-PNC23<br />
<strong>KT7</strong>-25S-PSC23<br />
Description<br />
Connecting Modules (forms Ecombo Starter) - ➊<br />
• Provides electrical and mechanical interconnection<br />
of <strong>KT7</strong> and CA4 (with AC or DC coils) or CA7 (with AC<br />
coils).<br />
• Suitable for reversing and wye-delta kits<br />
• Ecombo starter (with <strong>KT7</strong>-25) mounts on a single<br />
DIN-rail (<strong>KT7</strong> mounts on DIN-rail)<br />
• Ecombo starter (with <strong>KT7</strong>-45) can be mounted on two<br />
DIN-rails or on Mounting Modules (see selection table<br />
below)<br />
Description<br />
Connecting Modules<br />
• Provides electrical interconnection<br />
of <strong>KT7</strong> and CA7-(Y) two winding DC<br />
contactors<br />
• Coil Module extends A1/A2 terminals<br />
forward to facilitate wiring (required)<br />
• Contactor and motor protector must be<br />
mounted on two DIN-rails or on<br />
Mounting Modules (see selection table<br />
below)<br />
Description<br />
Mounting Module -<br />
Requires Connecting Module from tables above<br />
• Provides support for <strong>KT7</strong> + CA7 or CA4<br />
• Top rail is specifically designed for <strong>KT7</strong><br />
• Bottom rail is movable for easy assembly and<br />
disassembly<br />
• Complete unit mounts to two 35mm DIN-rails<br />
or one 70mm DIN-rail or screw mounts<br />
• 228 mm high<br />
Mounting Module -<br />
See Section D for Connecting Modules<br />
• Provides support for <strong>KT7</strong> + PCS or PDS<br />
Softstarter or CA7 + PCS or PDS Softstarter<br />
• Top rail is specifically designed for <strong>KT7</strong><br />
• Bottom rail is movable for easy assembly and<br />
disassembly<br />
• Complete unit mounts to two 35mm DIN-rails<br />
or one 70mm DIN-rail or screw mounts<br />
• 283 mm high<br />
For<br />
Connecting. . .<br />
For<br />
Connecting. . .<br />
To<br />
Contactor. . . Catalog Number ➊ Price<br />
<strong>KT7</strong>-25S CA4-9...12 <strong>KT7</strong>-25S-PEM12 24<br />
<strong>KT7</strong>-25S CA7-9...23 <strong>KT7</strong>-25S-PEC23 29<br />
<strong>KT7</strong>-25H CA7-9...23 <strong>KT7</strong>-25H-PEC23 29<br />
<strong>KT7</strong>-25H CA7-30...37 <strong>KT7</strong>-25H-PNC37 29<br />
<strong>KT7</strong>-45H CA7-30...37 <strong>KT7</strong>-45H-PNC37 29<br />
<strong>KT7</strong>-45H CA7-43 <strong>KT7</strong>-45H-PNC43 29<br />
To<br />
Contactor. . .<br />
Use<br />
Connector. . . ➊<br />
Price<br />
<strong>KT7</strong>-25S CA7-9Y...23Y <strong>KT7</strong>-25S-PNC23 29<br />
<strong>KT7</strong>-25H CA7-9Y...23Y <strong>KT7</strong>-25H-PNC23 29<br />
<strong>KT7</strong>-25H CA7-30Y...37Y <strong>KT7</strong>-25H-PNC37 29<br />
<strong>KT7</strong>-45H CA7-30Y...37Y <strong>KT7</strong>-45H-PNC37 29<br />
<strong>KT7</strong>-45H CA7-43Y <strong>KT7</strong>-45H-PNC43 29<br />
Width<br />
(mm) Catalog Number Price<br />
45 <strong>KT7</strong>-WS45RR 15<br />
54 <strong>KT7</strong>-WS54RR 17<br />
45 <strong>KT7</strong>-WM45RR 16<br />
54 <strong>KT7</strong>-WM54RR 18<br />
With<br />
Coil Module. . .<br />
Price<br />
<strong>KT7</strong>-25S-PSC23 14<br />
<strong>KT7</strong>-45H-PSC43 14<br />
➊ cURus Approved (File # E33916).<br />
F<br />
<strong>Motor</strong> <strong>Circuit</strong><br />
<strong>Controllers</strong><br />
<strong>KT7</strong><br />
Discount Schedule A-1<br />
F17
Accessories<br />
Series <strong>KT7</strong><br />
F<br />
<strong>Motor</strong> <strong>Circuit</strong><br />
<strong>Controllers</strong><br />
<strong>KT7</strong><br />
Compact Busbar System for <strong>KT7</strong>-25 and <strong>KT7</strong>-45 ➊➋<br />
A2E<br />
Accessory Description For Use With Catalog Number Price<br />
A3E<br />
Top view<br />
➊ UL Approved (File #E33916); CSA Approved (File #13908).<br />
➋ Compact busbar may not be applied with <strong>KT7</strong>-25-TE or <strong>KT7</strong>-45-TE Terminal<br />
Adaptors. Either Terminal Adaptors or Bus Bar may be used, not both.<br />
➌ <strong>KT7</strong>-25S and <strong>KT7</strong>-25H may not be combined without <strong>KT7</strong>-25-DB25H-54.<br />
Compact Busbar — 45 mm Spacing (Rated 63 A)<br />
• For use with front-mounted auxiliary contact<br />
Connects 2-<strong>KT7</strong>s<br />
Connects 3-<strong>KT7</strong>s<br />
Connects 4-<strong>KT7</strong>s<br />
Connects 5-<strong>KT7</strong>s<br />
Compact Busbar — 54 mm Spacing (Rated 63 A)<br />
• For use with side-mounted auxiliary contact<br />
Connects 2-<strong>KT7</strong>s<br />
Connects 3-<strong>KT7</strong>s<br />
Connects 4-<strong>KT7</strong>s<br />
Connects 5-<strong>KT7</strong>s<br />
Compact Busbar — 63 mm Spacing (Rated 63 A)<br />
• For use with side-mounted undervoltage trip or shunt trip<br />
Connects 2-<strong>KT7</strong>s<br />
Connects 3-<strong>KT7</strong>s<br />
Connects 4-<strong>KT7</strong>s<br />
Connects 5-<strong>KT7</strong>s<br />
Compact Busbar — 54mm Spacing (Rated 120 A)<br />
• For use with front-mounted auxiliary contact<br />
Connects 2-<strong>KT7</strong>s<br />
Connects 3-<strong>KT7</strong>s<br />
Connects 4-<strong>KT7</strong>s<br />
Compact Busbar — 63 mm Spacing (Rated 120 A)<br />
• For use with side-mounted auxiliary contact<br />
Connects 2-<strong>KT7</strong>s<br />
Connects 3-<strong>KT7</strong>s<br />
Connects 4-<strong>KT7</strong>s<br />
Jumper for <strong>KT7</strong>-25H to <strong>KT7</strong>-25S (Rated 63 A)<br />
• Accommodates difference in depth from <strong>KT7</strong>-25H to<br />
<strong>KT7</strong>-25S<br />
• Can be used with all other commoning links<br />
• 54 mm spacing<br />
Connects 2-<strong>KT7</strong>s<br />
Supply Block and Terminal<br />
• For power connection to Compact Busbar — 600V,<br />
<strong>KT7</strong>-25…63A max. / <strong>KT7</strong>-45…120A maximum<br />
• Top feed — overlaps commoning link<br />
• Meets requirements for terminal spacing from source<br />
in Type E applications<br />
Terminal Cover<br />
• For covering of unused connection terminals<br />
• IP2X finger protection<br />
<strong>KT7</strong>-25S or<br />
<strong>KT7</strong>-25H ➌<br />
(may not be<br />
combined)<br />
<strong>KT7</strong>-25S or<br />
<strong>KT7</strong>-25H ➌<br />
(may not be<br />
combined)<br />
<strong>KT7</strong>-25S or<br />
<strong>KT7</strong>-25H ➌<br />
<strong>KT7</strong>-45H<br />
<strong>KT7</strong>-45H<br />
<strong>KT7</strong>-25S to<br />
<strong>KT7</strong>-25H ➌<br />
<strong>KT7</strong>-25S or<br />
<strong>KT7</strong>-25H ➌<br />
<strong>KT7</strong>-25-DB-45-2<br />
<strong>KT7</strong>-25-DB-45-3<br />
<strong>KT7</strong>-25-DB-45-4<br />
<strong>KT7</strong>-25-DB-45-5<br />
<strong>KT7</strong>-25-DB-54-2<br />
<strong>KT7</strong>-25-DB-54-3<br />
<strong>KT7</strong>-25-DB-54-4<br />
<strong>KT7</strong>-25-DB-54-5<br />
<strong>KT7</strong>-25-DB-63-2<br />
<strong>KT7</strong>-25-DB-63-3<br />
<strong>KT7</strong>-25-DB-63-4<br />
<strong>KT7</strong>-25-DB-63-5<br />
<strong>KT7</strong>-45-DB-54-2<br />
<strong>KT7</strong>-45-DB-54-3<br />
<strong>KT7</strong>-45-DB-54-4<br />
<strong>KT7</strong>-45-DB-63-2<br />
<strong>KT7</strong>-45-DB-63-3<br />
<strong>KT7</strong>-45-DB-63-4<br />
28<br />
32<br />
36<br />
40<br />
28<br />
32<br />
36<br />
40<br />
28<br />
32<br />
36<br />
40<br />
56<br />
64<br />
72<br />
56<br />
64<br />
72<br />
<strong>KT7</strong>-25-DB25H-54-2 40<br />
<strong>KT7</strong>-25-A2E 34<br />
<strong>KT7</strong>-25-A3E 27<br />
<strong>KT7</strong>-45H <strong>KT7</strong>-45-A3E 80<br />
<strong>KT7</strong>-25...<br />
<strong>KT7</strong>-45H<br />
<strong>KT7</strong>-25-DBA<br />
<strong>KT7</strong>-45-DBA<br />
4<br />
5<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />
F18<br />
Discount Schedule A-1
Accessories<br />
Series <strong>KT7</strong><br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />
KF7 Fuse Holder to be used with <strong>KT7</strong> ➋<br />
Accessory<br />
Accessory<br />
Blown Fuse<br />
Indicator<br />
KF7 is Compatible with <strong>KT7</strong><br />
Compact Busbar<br />
Lockable in Open<br />
Position<br />
Connection<br />
Diagram Description Catalog Number Price<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
Description<br />
Auxiliary Contact for KF7 Fuse Holder<br />
(1 NO Late Make + NC Early Break)<br />
IEC/CE<br />
Approvals<br />
UL/CSA<br />
• NO Late Make, provides positive indication that power circuit is open<br />
• NC Early Break, provides capability for dropping out contactor before breaking<br />
current on fuse<br />
Catalog Number<br />
KF7 Fuse Holder, CC - 30A Yes Yes KF7-D3C-C30 38.00<br />
KF7 Fuse Holder, Midget - 30A Yes Yes KF7-D3M-C30 38.00<br />
KF7 Fuse Holder with Blown Fuse Indication, CC - 30A Yes Yes KF7-D3C-C30L 53.00<br />
KF7 Fuse Holder with Blown Fuse Indication, Midget - 30A Yes Yes KF7-D3M-C30L 53.00<br />
Connector to<br />
Contactor<br />
➊<br />
Price<br />
Applying KF7 with KTA7 <strong>Motor</strong> <strong>Circuit</strong><br />
<strong>Controllers</strong> and CA7 Contactors<br />
KF7 can be applied on the line side of a multiple<br />
small KTA7 motor circuit controller or a single KTA7<br />
controller and CA7 contactors to increase the shortcircuit<br />
protection of the group or a single branch<br />
circuit. KF7 is compatible with the <strong>KT7</strong> compact<br />
bus bars (as shown in Section F), which reduces<br />
the space requirement as well as installation time.<br />
Applying KF7 with CA7 Contactors<br />
KF7 can be applied on the line side of CA7<br />
contactors to increase the short-circuit withstand<br />
rating. The cUL withstand rating of CA7 when protected<br />
by Type”CC” fuses is increased to 100KAIC<br />
as shown on page A44. Similarly, when applying<br />
European Type “gG” fuses under CE rules, the<br />
withstand rating in combination with CA7 is also<br />
increased to 100 KAIC also shown on page A44.<br />
KF7-PE1-11 19.00<br />
F<br />
<strong>Motor</strong> <strong>Circuit</strong><br />
<strong>Controllers</strong><br />
➊ See “PNC” connections on pg. F17.<br />
➋ Connection diagrams on pg. F33.<br />
KF7<br />
Discount Schedule A-1<br />
F19
Technical Information<br />
Type 2 Coordination<br />
Type 2 Coordination per UL508E (Voltage: 480V, 60 HZ) ➊<br />
F<br />
<strong>Motor</strong> <strong>Circuit</strong><br />
<strong>Controllers</strong><br />
<strong>KT7</strong><br />
<strong>Motor</strong> Protector Catalog Number<br />
Definition of Type 2 short-circuit coordination per UL508E<br />
• The contactor or starter must not endanger persons or plant in the event of a<br />
short-circuit.<br />
• The contactor or starter must be suitable for continuous use.<br />
• No damage to the overload relay or other parts may occur with the exception of<br />
welding of the contactor or starter contacts if these can be easily separated<br />
without appreciable deformation (such as with a screwdriver).<br />
In the event of a short-circuit, fast-opening, strong current-limiting <strong>KT7</strong> motor<br />
protectors make it possible to build economical, fully short-circuit coordinated starter<br />
combinations in accordance with UL508E, Type 2 coordination.<br />
➊ The ratings in this table assume that the <strong>KT7</strong> and contactor are mounted<br />
separately and connected via cable.<br />
➋ Ratings apply to specified or larger contactor.<br />
Thermal Overload Release<br />
Setting Range [A]<br />
<strong>KT7</strong>-25S — Standard Interrupting Capacity<br />
Contactor Catalog<br />
Number ➋<br />
Short-<strong>Circuit</strong><br />
Current [kA]<br />
KTA7-25S-0.16A KTC7-25S-0.16A KTB7-25S-0.16A 0.10...0.16 CA7-9, CA4-9(12) 65<br />
KTA7-25S-0.25A KTC7-25S-0.25A KTB7-25S-0.25A 0.16...0.25 CA7-9, CA4-9(12) 65<br />
KTA7-25S-0.4A KTC7-25S-0.4A KTB7-25S-0.4A 0.25...0.40 CA7-9, CA4-9(12) 65<br />
KTA7-25S-0.63A KTC7-25S-0.63A KTB7-25S-0.63A 0.40...0.63 CA7-9, CA4-9(12) 65<br />
KTA7-25S-1A KTC7-25S-1A KTB7-25S-1A 0.63...1.0 CA7-9, CA4-9(12) 65<br />
KTA7-25S-1.6A KTC7-25S-1.6A KTB7-25S-1.6A 1.0...1.6 CA7-9, CA4-9(12) 65<br />
KTA7-25S-2.5A KTC7-25S-2.5A KTB7-25S-2.5A 1.6...2.5 CA7-9 50<br />
KTA7-25S-4A KTC7-25S-4A ~ 2.5...4.0 CA7-30 50<br />
KTA7-25S-6.3A KTC7-25S-6.3A ~ 4.0...6.3 CA7-30 50<br />
KTA7-25S-10A KTC7-25S-10A ~ 6.3...10.0 CA7-30 50<br />
KTA7-25S-16A KTC7-25S-16A ~ 10.0...16.0 CA7-30 10<br />
KTA7-25S-20A ~ ~ 14.5...20.0 CA7-30 10<br />
KTA7-25S-25A ~ ~ 18...25.0 CA7-30 10<br />
<strong>KT7</strong>-25H — High Interrupting Capacity<br />
KTA7-25H-2.5A ~ KTB7-25H-2.5A 1.6...2.5 CA7-9 65<br />
KTA7-25H-4A ~ KTB7-25H-4A 2.5...4.0 CA7-9 65<br />
KTA7-25H-6.3A ~ KTB7-25H-6.3A 4.0...6.3 CA7-9 65<br />
KTA7-25H-10A ~ KTB7-25H-10A 6.3...10.0 CA7-9 65<br />
KTA7-25H-16A KTC7-25H-16A KTB7-25H-16A 10.0...16.0 CA7-12 65<br />
KTA7-25H-20A KTC7-25H-20A ~ 14.5...20.0 CA7-23 65<br />
KTA7-25H-25A ~ KTB7-25H-25A 18.0...25.0 CA7-23 65<br />
<strong>KT7</strong>-45H — High Interrupting Capacity<br />
KTA7-45H-10A ~ ~ 6.3...10.0 CA7-9 65<br />
KTA7-45H-16A ~ ~ 10.0...16.0 CA7-12 65<br />
KTA7-45H-20A ~ ~ 14.5...20.0 CA7-16 65<br />
KTA7-45H-25A KTC7-45H-25A KTB7-45H-25A 18.0...25.0 CA7-23 65<br />
KTA7-45H-32A KTC7-45H-32A KTB7-45H-32A 23.0...32.0 CA7-30 65<br />
KTA7-45H-45A ~ KTB7-45H-45A 32.0...45.0 CA7-37 65<br />
KTA3-100 — High Interrupting Capacity<br />
KTA3-100-25A ~ ~ 16.0...25.0 CA7-16 65<br />
KTA3-100-40A ~ ~ 25.0...40.0 CA7-30 65<br />
KTA3-100-63A ~ ~ 40.0...63.0 CA7-43 42<br />
KTA3-100-90A ~ ~ 63.0...90.0 CA7-72 35<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />
F20<br />
Discount Schedule A-1
Technical Information<br />
Type 2 Coordination<br />
Type 2 Coordination per UL508E (Voltage: 600V, 60 HZ) ➊<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />
<strong>Motor</strong> Protector Catalog Number<br />
Definition of Type 2 short-circuit coordination per UL508E<br />
• The contactor or starter must not endanger persons or plant in the event of a<br />
short-circuit.<br />
• The contactor or starter must be suitable for continuous use.<br />
• No damage to the overload relay or other parts may occur with the exception of<br />
welding of the contactor or starter contacts if these can be easily separated<br />
without appreciable deformation (such as with a screwdriver).<br />
In the event of a short-circuit, fast-opening, strong current-limiting <strong>KT7</strong> motor<br />
protectors make it possible to build economical, fully short-circuit coordinated starter<br />
combinations in accordance with UL508E, Type 2 coordination.<br />
➊ The ratings in this table assume that the <strong>KT7</strong> and contactor are mounted<br />
separately and connected via cable.<br />
➋ Ratings apply to specified or larger contactor.<br />
Thermal Overload Release<br />
Setting Range [A]<br />
<strong>KT7</strong>-25S — Standard Interrupting Capacity<br />
Contactor Catalog<br />
Number ➋<br />
Short-<strong>Circuit</strong><br />
Current [kA]<br />
KTA7-25S-0.16A KTC7-25S-0.16A KTB7-25S-0.16A 0.10...0.16 CA7-9, CA4-9(12) 47<br />
KTA7-25S-0.25A KTC7-25S-0.25A KTB7-25S-0.25A 0.16...0.25 CA7-9, CA4-9(12) 47<br />
KTA7-25S-0.4A KTC7-25S-0.4A KTB7-25S-0.4A 0.25...0.40 CA7-9, CA4-9(12) 47<br />
KTA7-25S-0.63A KTC7-25S-0.63A KTB7-25S-0.63A 0.40...0.63 CA7-9, CA4-9(12) 47<br />
KTA7-25S-1A KTC7-25S-1A KTB7-25S-1A 0.63...1.0 CA7-9, CA4-9(12) 47<br />
KTA7-25S-1.6A KTC7-25S-1.6A KTB7-25S-1.6A 1.0...1.6 CA7-9, CA4-9(12) 47<br />
KTA7-25S-2.5A KTC7-25S-2.5A KTB7-25S-2.5A 1.6...2.5 CA7-16 10<br />
KTA7-25S-4A KTC7-25S-4A ~ 2.5...4.0 CA7-16 10<br />
KTA7-25S-6.3A KTC7-25S-6.3A ~ 4.0...6.3 CA7-23 5<br />
KTA7-25S-10A KTC7-25S-10A ~ 6.3...10.0 CA7-30 5<br />
KTA7-25S-16A KTC7-25S-16A ~ 10.0...16.0 CA7-30 5<br />
KTA7-25S-20A ~ ~ 14.5...20.0 CA7-30 5<br />
KTA7-25S-25A ~ ~ 18...25.0 CA7-30 5<br />
<strong>KT7</strong>-25H — High Interrupting Capacity<br />
KTA7-25H-2.5A ~ KTB7-25H-2.5A 1.6...2.5 CA7-9 30<br />
KTA7-25H-4A ~ KTB7-25H-4A 2.5...4.0 CA7-16 30<br />
KTA7-25H-6.3A ~ KTB7-25H-6.3A 4.0...6.3 CA7-23 30<br />
KTA7-25H-10A ~ KTB7-25H-10A 6.3...10.0 CA7-30 30<br />
KTA7-25H-16A KTC7-25H-16A KTB7-25H-16A 10.0...16.0 CA7-30 30<br />
KTA7-25H-20A KTC7-25H-20A ~ 14.5...20.0 CA7-30 5<br />
KTA7-25H-25A ~ KTB7-25H-25A 18.0...25.0 CA7-30 5<br />
<strong>KT7</strong>-45H — High Interrupting Capacity<br />
KTA7-45H-10A ~ ~ 6.3...10.0 CA7-30 30<br />
KTA7-45H-16A ~ ~ 10.0...16.0 CA7-30 30<br />
KTA7-45H-20A ~ ~ 14.5...20.0 CA7-30 30<br />
KTA7-45H-25A KTC7-45H-25A KTB7-45H-25A 18.0...25.0 CA7-30 30<br />
KTA7-45H-32A KTC7-45H-32A KTB7-45H-32A 23.0...32.0 CA7-30 30<br />
KTA7-45H-45A ~ KTB7-45H-45A 32.0...45.0 CA7-37 10<br />
KTA3-100 — High Interrupting Capacity<br />
KTA3-100-25A ~ ~ 16.0...25.0 CA7-16 43<br />
KTA3-100-40A ~ ~ 25.0...40.0 CA7-30 43<br />
KTA3-100-63A ~ ~ 40.0...63.0 CA7-43 18<br />
KTA3-100-90A ~ ~ 63.0...90.0 CA7-72 10<br />
F<br />
<strong>Motor</strong> <strong>Circuit</strong><br />
<strong>Controllers</strong><br />
<strong>KT7</strong><br />
Discount Schedule A-1<br />
F21
Technical Information<br />
<strong>KT7</strong> <strong>Motor</strong> <strong>Circuit</strong> Controller<br />
IEC Performance Data<br />
Catalog Number KTA7-25S...<br />
0.16A 0.25A 0.4A 0.63A 1A 1.6A 2.5A 4A 6.3A 10A 16A 20A 25A<br />
Rated Operational Current, I e<br />
[A] 0.16 0.25 0.4 0.63 1 1.6 2.5 4 6.3 10 16 20 25<br />
Magnetic Release Current [A] 2.1 3.3 5.2 8.2 13 21 33 52 82 130 208 260 325<br />
Switching of Standard<br />
Three-Phase <strong>Motor</strong>s<br />
AC-2, AC-3<br />
230/240V [kW] ~ ~ ~ 0.06/0.09 0.12 0.18/0.25 0.37 0.55/0.75 1.1/1.5 2.2 3.0/4.0 4.0/5.5 ~<br />
400/415V [kW] 0.02 0.06 0.09 0.12/0.18 0.25 0.37/0.55 0.75 1.1/1.5 2.2 3.0/4.0 5.5/7.5 7.5/10 11<br />
500V [kW] ~ ~ ~ 0.18 0.25/0.37 0.55/0.75 1.1 1.5/2.2 2.5/3.0 4.0/6.3 7.5/10 11 15<br />
690V [kW] ~ ~ ~ 0.25 0.37/0.55 0.75/1.1 1.8 2.2/3.0 4.0 5.5/7.5 11/13 15/17 18.5/22<br />
Back-up Fuses<br />
gG, gL, only if I cc<br />
>I cu<br />
230/240V [A] ➊ ➊ ➊ ➊ ➊ ➊ ➊ ➊ ➊ ➊ ➊ 100 100<br />
400/415V [A] ➊ ➊ ➊ ➊ ➊ ➊ ➊ ➊ ➊ ➊ 80 100 100<br />
440/460V [A] ➊ ➊ ➊ ➊ ➊ ➊ ➊ ➊ ➊ 63 63 80 80<br />
500V [A] ➊ ➊ ➊ ➊ ➊ ➊ ➊ ➊ ➊ 80 80 80 80<br />
690V [A] ➊ ➊ ➊ ➊ ➊ 16 20 35 50 50 63 63 63<br />
Ultimate Short-<strong>Circuit</strong><br />
Breaking Capacity<br />
I cu<br />
230/240V [kA] 100 100 100 100 100 100 100 100 100 100 100 50 50<br />
400/415V [kA] 100 100 100 100 100 100 100 100 100 100 65 50 15<br />
440/460V [kA] 100 100 100 100 100 100 100 100 100 50 10 6 6<br />
500V [kA] 100 100 100 100 100 100 100 100 100 50 10 6 6<br />
690V [kA] 100 100 100 100 100 8 8 8 4 4 3 3 3<br />
Rated Service Short-<strong>Circuit</strong><br />
Breaking Capacity<br />
I cs<br />
230/240V [kA] 100 100 100 100 100 100 100 100 100 100 100 50 50<br />
400/415V [kA] 100 100 100 100 100 100 100 100 100 100 50 15 15<br />
440/460V [kA] 100 100 100 100 100 100 100 100 100 50 6 6 6<br />
500V [kA] 100 100 100 100 100 100 100 100 100 50 6 6 6<br />
690V [kA] 100 100 100 100 100 8 8 8 4 4 3 3 3<br />
F<br />
<strong>Motor</strong> <strong>Circuit</strong><br />
<strong>Controllers</strong><br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />
F22<br />
Discount Schedule A-1
Technical Information<br />
<strong>KT7</strong> <strong>Motor</strong> <strong>Circuit</strong> Controller<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />
IEC Performance Data<br />
Catalog Number KTA7-25H...<br />
Catalog Number KTA7-45H...<br />
2.5A 4A 6.3A 10A 16A 20A 25A 10A 16A 20A 25A 32A 45A<br />
Rated Operational Current, I e<br />
[A] 2.5 4 6.3 10 16 20 25 10 16 20 25 32 45<br />
Magnetic Release Current [A] 33 52 82 130 208 260 325 130 208 260 325 416 585<br />
Switching of Standard<br />
Three-Phase <strong>Motor</strong>s<br />
AC-2, AC-3<br />
230/240V [kW] 0.37 0.55/0.75 1.1/1.5 2.2 3.0/4.0 4.0/5.5 ~ 2.2 3.0/4.0 4.0/5.5 5.5/6.3 7.5 11/13<br />
400/415V [kW] 0.75 1.1/1.5 2.2 3.0/4.0 5.5/7.5 7.5/10 11 3.0/4.0 5.5/7.5 7.5/10 11 15 18.5/22<br />
500V [kW] 1.1 1.5/2.2 2.5/3.0 4.0/6.3 7.5/10 11 15 4.0/6.3 7.5/10 11 15 15/20 22/30<br />
690V [kW] 1.8 2.2/3.0 4.0 5.5/7.5 11/13 15/17 18.5/22 5.5/7.5 11/13 15/17 18.5/22 22/25 30/40<br />
Back-up Fuses<br />
gG, gL, only if I cc<br />
>I cu<br />
230/240V [A] ➊ ➊ ➊ ➊ ➊ ➊ ➊ ➊ ➊ ➊ ➊ ➊ ➊<br />
400/415V [A] ➊ ➊ ➊ ➊ ➊ 100 100 80 100 100 100 125 125<br />
440/460V [A] ➊ ➊ ➊ ➊ ➊ 100 100 80 100 100 100 125 125<br />
500V [A] ➊ ➊ ➊ ➊ 80 80 80 80 100 100 100 125 125<br />
690V [A] 20 35 50 50 63 63 63 63 80 80 80 100 100<br />
Ultimate Short-<strong>Circuit</strong><br />
Breaking Capacity<br />
I cu<br />
230/240V [kA] 100 100 100 100 100 100 100 100 100 100 100 100 100<br />
400/415V [kA] 100 100 100 100 100 65 65 65 65 65 65 65 65<br />
440/460V [kA] 100 100 100 100 50 65 65 65 65 65 65 65 50<br />
500V [kA] 100 100 100 100 50 50 50 50 50 50 50 50 50<br />
690V [kA] 10 10 10 6 6 6 6 10 10 10 10 10 10<br />
Rated Service Short-<strong>Circuit</strong><br />
Breaking Capacity<br />
I cs<br />
230/240V [kA] 100 100 100 100 100 100 100 100 100 100 100 100 100<br />
400/415V [kA] 100 100 100 100 50 25 50 50 50 50 50 50 50<br />
440/460V [kA] 100 100 100 100 50 25 25 50 50 50 50 50 50<br />
500V [kA] 100 100 100 100 50 25 25 50 50 50 50 50 50<br />
690V [kA] 10 10 10 6 4 4 4 10 10 10 10 6 6<br />
F<br />
<strong>Motor</strong> <strong>Circuit</strong><br />
<strong>Controllers</strong><br />
➊ No backup fuse required.<br />
<strong>KT7</strong><br />
Discount Schedule A-1<br />
F23
Technical Information<br />
<strong>KT7</strong> <strong>Motor</strong> <strong>Circuit</strong> Controller<br />
F<br />
<strong>Motor</strong> <strong>Circuit</strong><br />
<strong>Controllers</strong><br />
IEC Performance Data<br />
Catalog Number KTB7-25S...<br />
0.16A 0.25A 0.4A 0.63A 1A 1.6A 2.5A<br />
Rated Operational Current, I e<br />
[A] 0.16 0.25 0.4 0.63 1 1.6 2.5<br />
Magnetic Release Current [A] 2.1 3.3 5.2 8.2 13 21 32<br />
Switching of Standard<br />
Three-Phase <strong>Motor</strong>s<br />
AC-2, AC-3<br />
230/240V [kW] ~ ~ ~ 0.06/0.09 0.12 0.18/0.25 0.37<br />
400/415V [kW] 0.02 0.06 0.09 0.12/0.18 0.25 0.37/0.55 0.75<br />
500V [kW] ~ ~ ~ 0.18 0.25/0.37 0.55/0.75 1.1<br />
690V [kW] ~ ~ ~ 0.25 0.37/0.55 0.75/1.1 1.8<br />
Back-up Fuses<br />
gG, gL, only if I cc<br />
>I cu<br />
230/240V [A] ➊ ➊ ➊ ➊ ➊ ➊ ➊<br />
400/415V [A] ➊ ➊ ➊ ➊ ➊ ➊ ➊<br />
440/460V [A] ➊ ➊ ➊ ➊ ➊ ➊ ➊<br />
500V [A] ➊ ➊ ➊ ➊ ➊ ➊ ➊<br />
690V [A] ➊ ➊ ➊ ➊ ➊ 16 20<br />
Ultimate Short-<strong>Circuit</strong><br />
Breaking Capacity<br />
I cu<br />
230/240V [kA] 100 100 100 100 100 100 100<br />
400/415V [kA] 100 100 100 100 100 100 100<br />
440/460V [kA] 100 100 100 100 100 100 100<br />
500V [kA] 100 100 100 100 100 100 100<br />
690V [kA] 100 100 100 100 100 10 8<br />
Rated Service Short-<strong>Circuit</strong><br />
Breaking Capacity<br />
I cs<br />
230/240V [kA] 100 100 100 100 100 100 100<br />
400/415V [kA] 100 100 100 100 100 100 100<br />
440/460V [kA] 100 100 100 100 100 100 100<br />
500V [kA] 100 100 100 100 100 100 100<br />
690V [kA] 100 100 100 100 100 8 8<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />
<strong>KT7</strong><br />
➊ No backup fuse required.<br />
F24<br />
Discount Schedule A-1
Technical Information<br />
<strong>KT7</strong> <strong>Motor</strong> <strong>Circuit</strong> Controller<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />
IEC Performance Data<br />
Catalog Number KTB7-25H...<br />
Catalog No. KTB7-45H...<br />
2.5A 4A 6.3A 10A 16A 25A 25A 32A 45A<br />
Rated Operational Current, I e<br />
[A] 2.5 4 6.3 10 16 25 25 32 45<br />
Magnetic Release Current [A] 32 52 82 130 208 325 325 416 585<br />
Switching of Standard<br />
Three-Phase <strong>Motor</strong>s<br />
AC-2, AC-3<br />
230/240V [kW] 0.37 0.55/0.75 1.1/1.5 2.2 3.0/4.0 ~ 5.5/6.3 7.5 11/13<br />
400/415V [kW] 0.75 1.1/1.5 2.2 3.0/4.0 5.5/7.5 11 11 15 18.5/22<br />
500V [kW] 1.1 1.5/2.2 2.5/3.0 4.0/6.3 7.5/10 15 15 15/20 22/30<br />
690V [kW] 1.8 2.2/3.0 4.0 5.5/7.5 11/13 18.5/22 18.5/22 22/25 30/40<br />
Back-up Fuses<br />
gG, gL, only if I cc<br />
>I cu<br />
230/240V [A] ➊ ➊ ➊ ➊ ➊ ➊ ➊ ➊ ➊<br />
400/415V [A] ➊ ➊ ➊ ➊ ➊ 100 100 125 125<br />
440/460V [A] ➊ ➊ ➊ ➊ 80 100 100 125 125<br />
500V [A] ➊ ➊ ➊ ➊ 80 80 100 125 125<br />
690V [A] 20 35 50 50 63 63 80 100 100<br />
Ultimate Short-<strong>Circuit</strong><br />
Breaking Capacity<br />
I cu<br />
230/240V [kA] 100 100 100 100 100 100 100 100 100<br />
400/415V [kA] 100 100 100 100 100 50 65 65 65<br />
440/460V [kA] 100 100 100 100 50 50 50 50 50<br />
500V [kA] 100 100 100 10 50 25 50 50 50<br />
690V [kA] 10 10 10 6 6 6 10 10 10<br />
Rated Service Short-<strong>Circuit</strong><br />
Breaking Capacity<br />
I cs<br />
230/240V [kA] 100 100 100 100 100 100 100 100 100<br />
400/415V [kA] 100 100 100 100 50 25 50 50 50<br />
440/460V [kA] 100 100 100 100 50 25 50 50 50<br />
500V [kA] 100 100 100 100 50 25 50 50 50<br />
690V [kA] 10 10 10 6 4 4 10 6 6<br />
F<br />
<strong>Motor</strong> <strong>Circuit</strong><br />
<strong>Controllers</strong><br />
➊ No backup fuse required.<br />
<strong>KT7</strong><br />
Discount Schedule A-1<br />
F25
Technical Information<br />
<strong>KT7</strong> <strong>Motor</strong> <strong>Circuit</strong> Controller<br />
F<br />
<strong>Motor</strong> <strong>Circuit</strong><br />
<strong>Controllers</strong><br />
IEC Performance Data<br />
Catalog Number KTC7-25S...<br />
0.16A 0.25A 0.4A 0.63A 1A 1.6A 2.5A 4A 6.3A 10A 16A<br />
Rated Operational Current, I e<br />
[A] 0.16 0.25 0.4 0.63 1 1.6 2.5 4 6.3 10 16<br />
Magnetic Release Current [A] 3.2 5.2 8.2 13 21 33 52 82 130 208 260<br />
Switching of Standard<br />
Three-Phase <strong>Motor</strong>s<br />
AC-2, AC-3<br />
230/240V [kW] ~ ~ ~ 0.06/0.09 0.12 0.18/0.25 0.37 0.55/0.75 1.1/1.5 2.2 3.0/4.0<br />
400/415V [kW] 0.02 0.06 0.09 0.12/0.18 0.25 0.37/0.55 0.75 1.1/1.5 2.2 3.0/4.0 5.5/7.5<br />
500V [kW] ~ ~ ~ 0.18 0.25/0.37 0.55/0.75 1.1 1.5/2.2 2.5/3.0 4.0/6.3 7.5/10<br />
690V [kW] ~ ~ ~ 0.25 0.37/0.55 0.75/1.1 1.8 2.2/3.0 4.0 5.5/7.5 11/13<br />
Back-up Fuses<br />
gG, gL, only if I cc<br />
>I cu<br />
230/240V [A] ➊ ➊ ➊ ➊ ➊ ➊ ➊ ➊ ➊ ➊ ➊<br />
400/415V [A] ➊ ➊ ➊ ➊ ➊ ➊ ➊ ➊ ➊ ➊ 80<br />
440/460V [A] ➊ ➊ ➊ ➊ ➊ ➊ ➊ ➊ ➊ ➊ 80<br />
500V [A] ➊ ➊ ➊ ➊ ➊ ➊ ➊ ➊ ➊ 80 80<br />
690V [A] ➊ ➊ ➊ ➊ ➊ 16 20 35 50 50 63<br />
Ultimate Short-<strong>Circuit</strong><br />
Breaking Capacity<br />
I cu<br />
230/240V [kA] 100 100 100 100 100 100 100 100 100 100 100<br />
400/415V [kA] 100 100 100 100 100 100 100 100 100 100 50<br />
440/460V [kA] 100 100 100 100 100 100 100 100 100 50 10<br />
500V [kA] 100 100 100 100 100 100 100 100 100 50 10<br />
690V [kA] 100 100 100 100 100 8 8 8 4 4 3<br />
Rated Service Short-<strong>Circuit</strong><br />
Breaking Capacity<br />
I cs<br />
230/240V [kA] 100 100 100 100 100 100 100 100 100 100 100<br />
400/415V [kA] 100 100 100 100 100 100 100 100 100 100 15<br />
440/460V [kA] 100 100 100 100 100 100 100 100 100 50 6<br />
500V [kA] 100 100 100 100 100 100 100 100 100 50 6<br />
690V [kA] 100 100 100 100 100 8 8 8 4 4 3<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />
<strong>KT7</strong><br />
➊ No backup fuse required.<br />
F26<br />
Discount Schedule A-1
Technical Information<br />
<strong>KT7</strong> <strong>Motor</strong> <strong>Circuit</strong> Controller<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />
IEC Performance Data<br />
Catalog No. KTC7-25H...<br />
Catalog No. KTC7-45H...<br />
16A 20A 25A 32A<br />
Rated Operational Current, I e<br />
[A] 16 20 25 32<br />
Magnetic Release Current [A] 260 325 416 585<br />
Switching of Standard<br />
Three-Phase <strong>Motor</strong>s<br />
AC-2, AC-3<br />
230/240V [kW] 3.0/4.0 4.0/5.5 5.5/6.3 7.5<br />
400/415V [kW] 5.5/7.5 7.5/10 11 15<br />
500V [kW] 7.5/10 11 15 15/20<br />
690V [kW] 11/13 15/17 18.5/22 22/25<br />
Back-up Fuses<br />
gG, gL, only if I cc<br />
>I cu<br />
230/240V [A] ➊ ➊ ➊ ➊<br />
400/415V [A] 80 100 100 125<br />
440/460V [A] 80 100 100 125<br />
500V [A] 80 80 100 125<br />
690V [A] 63 63 80 100<br />
Ultimate Short-<strong>Circuit</strong><br />
Breaking Capacity<br />
I cu<br />
230/240V [kA] 100 100 100 100<br />
400/415V [kA] 65 65 65 65<br />
440/460V [kA] 65 65 65 65<br />
500V [kA] 50 25 50 50<br />
690V [kA] 6 6 10 10<br />
Rated Service Short-<strong>Circuit</strong><br />
Breaking Capacity<br />
I cs<br />
230/240V [kA] 100 100 100 100<br />
400/415V [kA] 25 25 50 50<br />
440/460V [kA] 25 25 50 50<br />
500V [kA] 25 25 50 50<br />
690V [kA] 4 4 6 6<br />
F<br />
<strong>Motor</strong> <strong>Circuit</strong><br />
<strong>Controllers</strong><br />
➊ No backup fuse required.<br />
<strong>KT7</strong><br />
Discount Schedule A-1<br />
F27
Technical Information<br />
<strong>KT7</strong> <strong>Motor</strong> <strong>Circuit</strong> Controller<br />
F<br />
<strong>Motor</strong> <strong>Circuit</strong><br />
<strong>Controllers</strong><br />
<strong>KT7</strong><br />
General Data<br />
<strong>KT7</strong>-25S <strong>KT7</strong>-25H <strong>KT7</strong>-45H<br />
Rated Insulation Voltage<br />
IEC, SEV, VDE 0660<br />
690V<br />
UL, CSA<br />
600V<br />
Rated Impulse Withstand Voltage<br />
(main & auxiliary circuits)<br />
Uimp/pollution degree<br />
6kV/3<br />
Rated Frequency<br />
50/60 Hz<br />
Utilization Category<br />
• IEC 60949-2 (<strong>Motor</strong> Protector)<br />
A<br />
• IEC 60949-4-1 (<strong>Motor</strong> Starter)<br />
AC-3<br />
Life Span<br />
Mechanical [operations] 100,000 100,000 100,000<br />
<strong>Electric</strong>al (Ie max.) [operations] 100,000 100,000 100,000<br />
Switching Frequency [operations] max. 25/h. (motor starts)<br />
Ambient Temperature<br />
Storage<br />
-40º C...+80º C<br />
Operation<br />
-25º C...+60º C<br />
Resistance to Climatic Change IEC 68-2<br />
Moisture / Heat Resistance<br />
40ºC, 92% relative humidity, 56 days<br />
Moisture / Change Resistance<br />
23ºC, 93% relative humidity / 40ºC, 92% relative humidity, 56 days<br />
Site Altitude<br />
to 2,000 m N.N.<br />
Protection Class<br />
IP20 all round, when wired<br />
Resistance to Shock<br />
30 G, 11 ms<br />
Resistance to Vibration IEC 68-2<br />
Rated Thermal Current I th<br />
IEC, SEV, VDE 0660<br />
Up to 60º C ambient temperature [A] 0.1...25 1.6...25 6.3...45<br />
Overload Protection<br />
Characteristics<br />
Ambient temperature<br />
IEC 947-4-1 <strong>Motor</strong> protection (except KTB7)<br />
Compensation<br />
-20º C...+60º C<br />
Phase-failure protection<br />
yes, differential release<br />
Magnetic Release<br />
Response Current<br />
fixed setting<br />
13 x /emax. (for KTC7)<br />
16...20 x /emax. (for KTC7)<br />
I e<br />
max.=maximum values of setting ranges<br />
Total Power Loss P v<br />
<strong>Motor</strong> protector at rated load<br />
Operating temperature [W] 6...8 6...8 9...16<br />
Weights<br />
Description Catalog Number Weight<br />
KTA7-25S<br />
317 g<br />
KTA7-25H<br />
373 g<br />
KTA7-45H<br />
782 g<br />
KTB7-25S<br />
315 g<br />
<strong>Motor</strong> Protectors<br />
KTB7-25H<br />
365 g<br />
KTB7-45H<br />
782 g<br />
KTC7-25S<br />
315 g<br />
KTC7-25H<br />
365 g<br />
KTC7-45H<br />
782 g<br />
Auxiliary Contacts<br />
<strong>KT7</strong>-PE1<br />
<strong>KT7</strong>-PA1<br />
10 g<br />
<strong>KT7</strong>-PEF1<br />
<strong>KT7</strong>-PAF1<br />
15 g<br />
<strong>KT7</strong>-UA-✱<br />
108 g<br />
Undervoltage Trip<br />
<strong>KT7</strong>-<strong>AA</strong>-✱<br />
110 g<br />
<strong>KT7</strong>-UA-L20-✱ 116 g<br />
Anti-Tamper Cover <strong>KT7</strong>-25-CA 2 g<br />
Lockable Twist Knob<br />
<strong>KT7</strong>-KN<br />
<strong>KT7</strong>-KRY<br />
5 g<br />
Locking Tag <strong>KT7</strong>-DS 30 g<br />
Door Coupling Handle<br />
<strong>KT7</strong>-HTN<br />
<strong>KT7</strong>-HTRY<br />
123 g<br />
Description Catalog Number Weight<br />
Extension Shaft <strong>KT7</strong>-HT 46 g<br />
Lengend Plate <strong>KT7</strong>-HTFC 4 g<br />
Feeder Terminal<br />
<strong>KT7</strong>-25-A3<br />
<strong>KT7</strong>-45-A3<br />
172 g<br />
<strong>KT7</strong>-25-DB-45-2 47 g<br />
<strong>KT7</strong>-25-DB-45-3 80 g<br />
<strong>KT7</strong>-25-DB-45-4 104 g<br />
<strong>KT7</strong>-25-DB-45-5 132 g<br />
<strong>KT7</strong>-25-DB-54-2 52 g<br />
Commoning Links<br />
<strong>KT7</strong>-25-DB-54-3 86 g<br />
<strong>KT7</strong>-25-DB-54-4 118 g<br />
<strong>KT7</strong>-25-DB-54-5 154 g<br />
<strong>KT7</strong>-25-DB-63-2 56 g<br />
<strong>KT7</strong>-25-DB-63-3 92 g<br />
<strong>KT7</strong>-25-DB-63-4 134 g<br />
<strong>KT7</strong>-25-DB-63-5 170 g<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />
F28<br />
Discount Schedule A-1
Technical Information<br />
<strong>KT7</strong> <strong>Motor</strong> <strong>Circuit</strong> Controller<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />
General Data<br />
Conformity to Standards<br />
Approvals<br />
Terminal Parts<br />
Terminal Type<br />
Accessories for <strong>KT7</strong> <strong>Motor</strong> <strong>Circuit</strong> <strong>Controllers</strong><br />
Auxiliary Contact<br />
Blocks for<br />
Front Mounting<br />
Catalog Number<br />
<strong>KT7</strong>-PE1, <strong>KT7</strong>-PEF1<br />
Auxiliary Contact<br />
Blocks for<br />
Right-Side Mounting<br />
Catalog Number<br />
<strong>KT7</strong>-PA1, <strong>KT7</strong>-PAF1<br />
Rated Thermal Current I th<br />
at 40ºC ambient temperature 5 10<br />
at 40ºC ambient temperature [A] 4 6<br />
Contact Class Coordination<br />
According to NEMA AC B 300 B 600<br />
(UL/CSA Standards) DC Q 300 Q 600<br />
Back-Up Fuses gG, gL [A] 10 10<br />
Rated Thermal Current I th<br />
AC-15 [V] 24 120 240 24 120 240 415 690<br />
[A] 4 3 1.5 6 5 3 2 0.7<br />
DC-13 [V] 24 120 240 24 120 240 415<br />
[A] 2 0.5 0.25 2 0.5 0.25 0.15<br />
Terminal Parts<br />
Terminal Type<br />
<strong>KT7</strong>-25S <strong>KT7</strong>-25H <strong>KT7</strong>-45H<br />
IEC 60947-1, -2; -4-1<br />
EN 60947-1, -2; -4-1<br />
UL 508; CSA 22.2<br />
CE, UL, CSA<br />
Screwdriver Pozidriv No. 2/Blade No. 3 Pozidriv No. 2/Blade No. 3<br />
1 conductor [mm 2 ]/[AWG] 1...4 / No. 16...10 2.5...16 / No. 14...4<br />
2 conductor [mm 2 ]/[AWG] 1...4 / No. 16...10 2.5...10 / No. 14...4<br />
1 conductor [mm 2 ]/[AWG] 1...6 / No. 16...10 2.5...25 / No. 14...4<br />
2 conductor [mm 2 ]/[AWG] 1...6 / No. 16...10 2.5...16 / No. 14...4<br />
1 conductor [mm 2 ]/[AWG] 1.5...6 / No. 16...10 2.5...25 / No. 14...4<br />
2 conductor [mm 2 ]/[AWG] 1.5...6 / No. 16...10 2.5...16 / No. 14...4<br />
Tightening torque [Nm]/[lb-in.] 2...2.5 / 18...22 3...3.5 / 27...31<br />
Screwdriver Pozidriv No. 2/Blade No. 3<br />
1 conductor [mm 2 ]/[AWG] 0.5...2.5 / No. 18...14<br />
2 conductor [mm 2 ]/[AWG] 0.5...2.5 / No. 18...14<br />
1 conductor [mm 2 ]/[AWG] 0.75...2.5 / No. 18...14<br />
2 conductor [mm 2 ]/[AWG] 0.75...2.5 / No. 18...14<br />
1 conductor [mm 2 ]/[AWG] 0.75...2.5 / No. 18...14<br />
2 conductor [mm 2 ]/[AWG] 0.75...2.5 / No. 18...14<br />
Tightening torque [Nm]/[lb-in.] 1.2...1.5 / 10.6...13<br />
Lockable Twist Knob (<strong>KT7</strong>-KN & <strong>KT7</strong>-KRY)<br />
Tightening torque [Nm]/[lb-in.] 1 / 8.8 (T10)<br />
Mounting Depth – Door Coupling Handles (All <strong>KT7</strong>-HT...)<br />
Mounting Depth when using motor circuit controller:<br />
<strong>KT7</strong>-25S [mm]/[in.] 105.5 mm ± 5 mm (4.15” ± 3/16”)<br />
<strong>KT7</strong>-25H [mm]/[in.] 114.5 mm ± 5 mm (4.5” ± 3/16”)<br />
<strong>KT7</strong>-45H [mm]/[in.] 137.1 mm ± 5 mm (5.4” ± 3/16”)<br />
Mounting Depth – Extension Shaft (<strong>KT7</strong>-HT)<br />
Mounting Depth range when using motor circuit controller:<br />
<strong>KT7</strong>-25S [mm]/[in.] 117...338 mm (4.6”...13.3”)<br />
<strong>KT7</strong>-25H [mm]/[in.] 126...347 mm (5.0”...13.7”)<br />
<strong>KT7</strong>-45H [mm]/[in.] 149...369 mm (5.4”...14.5”)<br />
F<br />
<strong>Motor</strong> <strong>Circuit</strong><br />
<strong>Controllers</strong><br />
<strong>KT7</strong><br />
Discount Schedule A-1<br />
F29
Technical Information<br />
<strong>KT7</strong> <strong>Motor</strong> <strong>Circuit</strong> Controller<br />
F<br />
<strong>Motor</strong> <strong>Circuit</strong><br />
<strong>Controllers</strong><br />
Accessories<br />
Undervoltage Trip for<br />
Left-Side Mounting<br />
Cat. Number <strong>KT7</strong>-UA-*<br />
Undervoltage Trip with<br />
2 Auxiliary Contacts for<br />
Left-Side Mounting<br />
Cat. Number <strong>KT7</strong>-UA-L20-*<br />
Shunt Trip for<br />
Left-Side Mounting<br />
Cat. Number <strong>KT7</strong>-<strong>AA</strong>-*<br />
Actuating Voltage Pull-in 0.85...1.1 x U s 0.85...1.1 x U s<br />
0.7...1.1 x U s<br />
Drop-out 0.7...0.35 x U s 0.7...0.35 x U s<br />
Rated Control Voltage minimum 21V 50 Hz, 24V 60 Hz 21V 50 Hz, 24V 60 Hz 21V 50 Hz, 24V 60 Hz<br />
maximum 600V 50 Hz 600V 50 Hz 600V 50 Hz<br />
On-Time 100% 100% 100%<br />
Coil Rating Pull-in 8.5 VA, 6 W 8.5 VA, 6 W 8.5 VA, 6 W<br />
Hold 3 VA, 1.2 W 3 VA, 1.2 W 3 VA, 1.2 W<br />
Terminal Parts<br />
Terminal Type<br />
Screwdriver Pozidriv No. 2/Blade No. 3<br />
1 conductor [mm 2 ]/[AWG] 0.5...2.5 / No. 18...14<br />
2 conductor [mm 2 ]/[AWG] 0.75...2.5 / No. 18...14<br />
1 conductor [mm 2 ]/[AWG] 0.75...2.5 / No. 18...14<br />
2 conductor [mm 2 ]/[AWG] 0.75...2.5 / No. 18...14<br />
1 conductor [mm 2 ]/[AWG] 0.75...2.5 / No. 18...14<br />
2 conductor [mm 2 ]/[AWG] 0.75...2.5 / No. 18...14<br />
Tightening torque [Nm]/[lb-in.] 1.2...1.5 / 10.6...13.3<br />
Feeder Terminal<br />
<strong>KT7</strong>-25-A3(E)<br />
Compact Busbar<br />
<strong>KT7</strong>-25-DB...<br />
Feeder Terminal<br />
<strong>KT7</strong>-45-A3(E)<br />
Compact Bushbar<br />
<strong>KT7</strong>-45-DB...<br />
Rated Thermal Current I th<br />
[V] 600 600 600 600<br />
at 60º C ambient temperature [A] 64 64 120 120<br />
1 conductor [mm 2 ]/[AWG] 4...16 / No. 12...6 ~ #8...1/0 ~<br />
1 conductor [mm 2 ]/[AWG] 6...25 / No. 14...4 ~ ~<br />
1 conductor [mm 2 ]/[AWG] 6...25 / No. 14...4 ~ ~<br />
Tightening torque [Nm]/[lb-in.] 3 / 27 ~ 27...54 ~<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />
<strong>KT7</strong><br />
F30<br />
Discount Schedule A-1
Technical Information<br />
<strong>KT7</strong> <strong>Motor</strong> <strong>Circuit</strong> Controller<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />
Time-Current Characteristic<br />
<strong>KT7</strong> <strong>Manual</strong> <strong>Motor</strong> Starter/Protector<br />
Cut-off Current<br />
<strong>KT7</strong>-25S<br />
1. Thermal Release Trip Current<br />
The adjustable current-dependent delayed bimetal release protects<br />
motors against overload. The curve shows the mean operating<br />
current at an ambient temperature of 20°C starting from the cold<br />
state. Careful testing and setting ensures effective motor protection<br />
even in the case of single-phasing. The overload characteristic is<br />
also valid for transformer protection.<br />
2. Magnetic Release Trip Current<br />
The instantaneous magnetic trip has a fixed operating current<br />
setting. This corresponds to 13 times the maximum value of setting<br />
range (high inrush protection -20 x I e<br />
maximum). At a lower<br />
overload setting the magnetic trip is correspondingly higher.<br />
Current Setting I ef<br />
The overload trip corresponds to a thermal overload relay in a<br />
motor starter conforming to IEC 947-4-1. If a different value is<br />
prescribed (e.g., reduced I e<br />
for cooling medium having a temperature<br />
higher than 40°C or a place of installation higher than 2000 m<br />
above sea level), the setting current is equal to the reduced rated<br />
current I e<br />
of the motor.<br />
F<br />
<strong>Motor</strong> <strong>Circuit</strong><br />
<strong>Controllers</strong><br />
<strong>KT7</strong><br />
Discount Schedule A-1<br />
F31
Technical Information<br />
<strong>KT7</strong> <strong>Motor</strong> <strong>Circuit</strong> Controller<br />
F<br />
<strong>Motor</strong> <strong>Circuit</strong><br />
<strong>Controllers</strong><br />
Cut-off Current<br />
<strong>KT7</strong>-25H and <strong>KT7</strong>-45H<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />
<strong>KT7</strong><br />
F32<br />
Discount Schedule A-1
Technical Information<br />
KF7 with <strong>KT7</strong> <strong>Motor</strong> <strong>Circuit</strong> Controller<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />
<strong>KT7</strong> <strong>Motor</strong> <strong>Circuit</strong> KF7 Fuse <strong>Controllers</strong> Holder (without used with Terminal CA7 Contactor Adaptor <strong>KT7</strong>-25[45]-TE)<br />
<br />
<br />
<br />
<br />
<br />
<br />
KF7 Fuse Holder used with KTA7 <strong>Motor</strong> <strong>Circuit</strong> Controller and CA7 Contactor<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
F<br />
<strong>Motor</strong> <strong>Circuit</strong><br />
<strong>Controllers</strong><br />
KF7<br />
Discount Schedule A-1<br />
F33
Technical Information<br />
<strong>KT7</strong> <strong>Motor</strong> <strong>Circuit</strong> Controller<br />
F<br />
<strong>Motor</strong> <strong>Circuit</strong><br />
<strong>Controllers</strong><br />
<strong>KT7</strong><br />
• Dimensions are shown in millimeters (inches).<br />
• Dimensions are not intended to be used for<br />
manufacturing purposes.<br />
<strong>KT7</strong> Bus Bar and Supply Blocks<br />
CA7/<strong>KT7</strong> Connection Modules and Kits<br />
1) Ecombo Modules<br />
<strong>Electric</strong>al and mechanical connection between motor circuit controller and contactors with AC coil. For CA7-9...23 only. Compatible with the reversing- and WYE-delta<br />
starter components.<br />
2) Standard Connection Modules<br />
<strong>Electric</strong>al connection between motor circuit controller and contactors with AC coil. For CA7-9...45. Compatible with the reversing- and WYE-delta starter components.<br />
3) Coil Extension Modules<br />
Simplifies access to the coil terminals on 3-component starters.<br />
For CA7-9...23 = <strong>KT7</strong>-25S-PSC23<br />
For CA7-30...43 = <strong>KT7</strong>-45H-PSC43<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />
F34<br />
Discount Schedule A-1
Dimensions<br />
<strong>KT7</strong> <strong>Motor</strong> <strong>Circuit</strong> Controller<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />
• Dimensions are shown in millimeters (inches).<br />
• Dimensions are not intended to be used for<br />
manufacturing purposes.<br />
<strong>KT7</strong> <strong>Motor</strong> <strong>Circuit</strong> <strong>Controllers</strong> (without Terminal Adaptor <strong>KT7</strong>-25[45]-TE)<br />
a b c1 c2<br />
<strong>KT7</strong>-25S 117...338 105.5 ± 5 49.5 40.5<br />
<strong>KT7</strong>-25H 126...347 114.5 ± 5 49.5 40.5<br />
<strong>KT7</strong>-45H 148.6...369.6 137.1 ± 5 59.35 50.35<br />
➊ Mounting on 35 mm DIN Rail EN 50 022-35<br />
➋ Auxiliary contact (side-mounted).<br />
Adds 9mm (23/64)<br />
➌ Undervoltage trip or Shunt trip<br />
➍ Auxiliary contact (front-mounted)<br />
F<br />
<strong>Motor</strong> <strong>Circuit</strong><br />
<strong>Controllers</strong><br />
<strong>KT7</strong><br />
Discount Schedule A-1<br />
F35
Dimensions<br />
<strong>KT7</strong> <strong>Motor</strong> <strong>Circuit</strong> Controller<br />
F<br />
<strong>Motor</strong> <strong>Circuit</strong><br />
<strong>Controllers</strong><br />
• Dimensions are shown in millimeters (inches).<br />
• Dimensions are not intended to be used for<br />
manufacturing purposes.<br />
<strong>KT7</strong> <strong>Motor</strong> <strong>Circuit</strong> <strong>Controllers</strong> (without Terminal Adaptor <strong>KT7</strong>-25[45]-TE)<br />
<strong>KT7</strong>-25S with Terminal Adaptor <strong>KT7</strong>-25-TE<br />
<strong>KT7</strong>-45H with Terminal Adaptor <strong>KT7</strong>-45-TE<br />
<strong>KT7</strong>-25H with Terminal Adaptor <strong>KT7</strong>-25-TE<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />
<strong>KT7</strong><br />
F36<br />
Discount Schedule A-1
Dimensions<br />
Mounting Modules<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />
Mounting Modules<br />
• Dimensions are shown in millimeters (inches).<br />
• Dimensions are not intended to be used for manufacturing purposes.<br />
Mounting Modules – <strong>KT7</strong>-WS45(54)RR & <strong>KT7</strong>-WM45(54)RR<br />
Catalog Number A B C D E F<br />
KA7-WS45RR 228<br />
(8-31/32)<br />
KA7-WS5RR 228<br />
(8-31/32)<br />
KA7-WM45RR 283<br />
(11-9/64)<br />
KA7-WM5RR 283<br />
(11-9/64)<br />
45<br />
(1-25/32)<br />
54<br />
(2-1/8)<br />
45<br />
(1-25/32)<br />
54<br />
(2-1/8)<br />
69<br />
(2-23/32)<br />
69<br />
(2-23/32)<br />
69<br />
(2-23/32)<br />
69<br />
(2-23/32)<br />
165.5<br />
(6-35/64)<br />
174<br />
(6-27/32)<br />
166.5<br />
(6-35/64)<br />
174<br />
(6-27/32)<br />
210<br />
(8-17/64)<br />
210<br />
(8-17/64)<br />
265<br />
(10-7/16)<br />
265<br />
(10-7/16)<br />
35<br />
(1-3/8)<br />
40<br />
(1-37/64)<br />
40<br />
(1-37/64)<br />
40<br />
(1-37/64)<br />
F<br />
<strong>Motor</strong> <strong>Circuit</strong><br />
<strong>Controllers</strong><br />
<strong>KT7</strong><br />
Discount Schedule A-1<br />
F37
Technical Information<br />
KTA3-100 <strong>Motor</strong> <strong>Circuit</strong> Controller<br />
F<br />
<strong>Motor</strong> <strong>Circuit</strong><br />
<strong>Controllers</strong><br />
IEC Performance Data<br />
(CSA C22.2, UL 508 No. 14 in connection with a short-circuit protection device<br />
Catalog No. KTA3-100...<br />
25A 40A 63A 90A<br />
Maximum Short-<strong>Circuit</strong> Current<br />
480V [kA] 65 65 42 35<br />
600V [kA] 42 42 18 10<br />
<strong>Motor</strong> Load, Single-Phase<br />
115V [HP] 2 3 5 7-1/2<br />
200V [HP] 3 5 10 15<br />
230V [HP] 3 7-1/2 10 20<br />
<strong>Motor</strong> Load, Three-Phase<br />
200V [HP] ~ ~ ~ ~<br />
230V [HP] 7-1/2 10 20 30<br />
460V [HP] 15 30 40 60<br />
575V [HP] 20 30 60 75<br />
Maximum Rated Current of the<br />
Protective Device [A] 2000<br />
IEC Performance Data<br />
Catalog No. KTA3-100...<br />
25A 40A 63A 90A<br />
Switching of Three-Phase <strong>Motor</strong>s<br />
AC-2, AC-3<br />
230/240V [kW] 5.5/7.5 10/11 12.5/20 22/25<br />
400/415V [kW] 7.5/12.5 15/22 25/31.5 37/45<br />
500V [kW] 11/16 18.5/25 30/40 45/55<br />
690V [kW] 15/22 25/30 37/55 63/75<br />
<strong>Motor</strong> Load, Single-Phase<br />
gG, aM, only if I cc<br />
>I cu<br />
230/240V [A] ~ ~ ~ ~<br />
400/415V [A] 160 160 160 160<br />
500V [A] 160 160 160 160<br />
690V [A] 160 160 160 160<br />
Ultimate Short-<strong>Circuit</strong> Breaking Capacity I cu<br />
200V [kA] ~ ~ ~ ~<br />
230V [kA] 7-1/2 10 20 30<br />
460V [kA] 15 30 40 60<br />
575V [kA] 20 30 60 75<br />
Rated Short-<strong>Circuit</strong> Breaking Capacity I cs<br />
200V [kA] 100 100 100 100<br />
230V [kA] 65 50 50 25<br />
460V [kA] 50 25 25 13<br />
575V [kA] 15 8 6 6<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />
KTA3<br />
F38 Discount Schedule A-1
Technical Information<br />
Series KTA3-100 <strong>Motor</strong> <strong>Circuit</strong> Controller<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />
General Data<br />
Catalog Number KTA3-100<br />
Rated Isolation Voltage<br />
IEC, SEV, VDE 0660<br />
690V<br />
UL, CSA<br />
600V<br />
Rated Frequency<br />
40...80 Hz<br />
Lifespan<br />
Mechanical<br />
30,000 operations<br />
<strong>Electric</strong>al<br />
10,000 operations at 63 A<br />
5,000 operations at 90 A<br />
Switching Frequency<br />
maximum 20 ops/hr<br />
Ambient Temperature<br />
Storage<br />
-25...+80ºC (-13...176ºF)<br />
Operation<br />
-25...+60ºC (-13...140ºF)<br />
Corrosion Resistance C IV (per IEC 68)<br />
Resistance to heat and humidity<br />
40ºC, 92%, 56 days<br />
Resistance to cyclic heat and humidity<br />
23ºC, 83%/40ºC, 93%, 56 cycles<br />
Type of Protection<br />
IP20 enclosed state<br />
Resistance to Shock [G] 30, 11 ms<br />
Resistance to Vibration<br />
Frequency range<br />
10...150 Hz<br />
In all directions<br />
in testing<br />
Rated Thermal Current I th<br />
IEC, SEV, VDE 0660 ~<br />
At 40ºC ambient temperature<br />
16...90 A<br />
At 60ºC ambient temperature<br />
4 adjustment ranges<br />
Rated current I e<br />
16...90 A<br />
Rated Impulse Voltage/Pollution<br />
Main circuits<br />
6 kV/3<br />
Auxiliary circuits<br />
6 kV/3<br />
Overload Protection<br />
Characteristics motor protection per IEC 947<br />
Temperature compensation<br />
-25...+60ºC (-4...140ºF)<br />
Phase failure protection<br />
differential release<br />
Magnetic Release<br />
Operating current<br />
fixed setting<br />
14 x I e<br />
maximum<br />
I e<br />
maximum = maximum value of adjustment range<br />
Power Loss P v<br />
At maximum rated current and with<br />
switch at rated operating temperature<br />
33 W<br />
Standards<br />
IEC 947-1/2/4/5;<br />
EN 60947;<br />
UL 508; CSA 22.2<br />
Approvals<br />
CE, CSA, UL<br />
Lloyd’s Register of Shipping<br />
Terminals<br />
Terminal Type<br />
Flexible [mm 2 ] 1 x 2.5...35<br />
Stranded [mm 2 ] 1 x 4...50<br />
Breakaway Torque [Nm] 6...10<br />
Stranded [mm 2 ] No. 12...2<br />
Breakaway Torque [lb-in.] 53...120<br />
Weight<br />
3-pole circuit breaker [g] 1845 (4.10)<br />
F<br />
<strong>Motor</strong> <strong>Circuit</strong><br />
<strong>Controllers</strong><br />
KTA3<br />
Discount Schedule A-1<br />
F39
Technical Information<br />
Series KTA3-100 <strong>Motor</strong> <strong>Circuit</strong> Controller<br />
F<br />
<strong>Motor</strong> <strong>Circuit</strong><br />
<strong>Controllers</strong><br />
General Data<br />
Integrated Short-<strong>Circuit</strong> Indicator<br />
in Catalog Number KTA3-100-UA...and KTA3-100<strong>AA</strong>...<br />
Rated Thermal Current I th<br />
At 40ºC ambient temperature [A] 2<br />
At 60ºC ambient temperature [A] 2<br />
Back-Up Fuse gl, gL [A] 10<br />
Rated Current<br />
Terminals<br />
Terminal Type<br />
AC-15<br />
AC-15<br />
AC-14<br />
AC-14<br />
24V 110V 230V 500V<br />
1.5A 1.5A 1.0A 0.75A<br />
24V 48V 60V ~<br />
1.5A 0.5A 0.4A ~<br />
Flexible [mm 2 ] 2 x 0.75...2.5<br />
Stranded [mm 2 ] 2 x 0.75...2.5<br />
Breakaway Torque [Nm] 1...1.5<br />
Stranded [mm 2 ] No. 18...12<br />
Breakaway Torque [lb-in.] 8.8...10.3<br />
Weight [g (lb)] 91 (0.21)<br />
Operating Voltage<br />
Pick-up<br />
Drop-out<br />
Duty cycle<br />
Undervoltage Trip Unit for Front Mounting<br />
on Catalog Number KTA3-100<br />
0.85...1.1 x Us<br />
0.7...0.35 x Us<br />
continuous<br />
Control Voltage min. 21V 50 Hz / 24V 60 Hz<br />
max.<br />
600V 50 Hz<br />
Coil Performance<br />
Terminals<br />
Terminal Type<br />
pick-up<br />
drop-out<br />
upon inquiry<br />
Flexible [mm 2 ] / [AWG] 2 x 0.50...2.5 (18...14)<br />
Stranded [mm 2 ] / [AWG] 2 x 0.75...2.5 (18...14)<br />
Tightening Torque [Nm] / [lb-in] 1.2...1.5 (10.6...13.3)<br />
Weight [g (lb)] 94 (0.21)<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />
KTA3<br />
F40 Discount Schedule A-1
Technical Information<br />
KTA3-100 <strong>Motor</strong> <strong>Circuit</strong> Controller<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />
Cut-Off Current<br />
KTA3-100 <strong>Motor</strong> <strong>Circuit</strong> Controller<br />
Maximum Cut-Off Current<br />
Rated Operating Voltage 415V<br />
Protection of PVC Insulated Leads Against Overload and During Short-<strong>Circuit</strong><br />
Protected Minimum Copper Cross-Section at 400V 50 Hz<br />
Catalog Number 10 mm 2 6 mm 2 4 mm 2 2.5 mm 2 1.5 mm 2 1 mm 2 0.75 mm 2<br />
KTA3-100-25A • • • • ~ ~ ~<br />
KTA3-100-40A • • • ~ ~ ~ ~<br />
KTA3-100-63A • • ~ ~ ~ ~ ~<br />
KTA3-100-90A • ~ ~ ~ ~ ~ ~<br />
Maximum Forward Energy<br />
Rated Operating Voltage 415V<br />
As per IEC 364 and CENELEC coordination documents 384-3 and 384-3.<br />
In the Bulletin KTA3-100 <strong>Motor</strong> Protector, overload protection is achieved by means of the adjustable thermal releases. The maximum possible tripping current is substantially<br />
lower than in fused overload protection. Short-circuit protection is provided by the non-adjustable magnetic release which is capable of opening the main contacts very quickly.<br />
The short total breaking time limits temperature rise in the lead to a minimum in the event of a short-circuit.<br />
F<br />
<strong>Motor</strong> <strong>Circuit</strong><br />
<strong>Controllers</strong><br />
KTA3<br />
Discount Schedule A-1<br />
F41
Technical Information<br />
KTA3-100 <strong>Motor</strong> <strong>Circuit</strong> Controller<br />
F<br />
<strong>Motor</strong> <strong>Circuit</strong><br />
<strong>Controllers</strong><br />
KTA3<br />
Time-Current Characteristic<br />
KTA3-100 <strong>Manual</strong> <strong>Motor</strong> Starter/Protector<br />
Note: In certain applications such as in multi-speed motors or star-delta starters<br />
for heavy duty start and/or reduced motor lead cross-sections, the KTA3-100<br />
devices are used only as short-circuit protection, while overload protection is<br />
accomplished by thermal overload relays. The KTA3-100 motor protector must be<br />
set for a 20% higher current so that only the downstream thermal overload relays<br />
trip in the event of an overload.<br />
1. Thermal Release Operating Current<br />
The adjustable current-dependent delayed bimetal release<br />
protects motors against overload. The characteristic shows the<br />
mean at 20°C ambient temperature starting from the cold state.<br />
In equipment at operating temperature, release time is less<br />
than or equal to release time from the cold state. The precise<br />
routine test guarantees motor protection even when a phase is<br />
interrupted.<br />
<strong>Motor</strong> protection in protection type EExe: Pursuant to VDE<br />
0165/83, the release time of the cold overload release must be<br />
less than the allowed locked-rotor time t E<br />
of the motor.<br />
The specific tripping characteristics must be available at the<br />
operating site. If necessary, they can be ordered from the<br />
appropriate Sprecher + Schuh Sales Office. For new systems,<br />
protection equipment must be provided for motors in<br />
accordance with VDE 0165/83, section 6.1.4.3.3. Such<br />
protection equipment must ensure motor protection even in the<br />
event of a phase failure.<br />
2. Operating Current for Magnetic Releases<br />
Electromagnetic instantaneous releases react at a set tripping<br />
current. At the upper thermal release setting, this tripping<br />
current is 11 times or 14 times the set current at a lower<br />
setting.<br />
Current To Be Set<br />
Thermal releases meet the requirements for a thermal release<br />
for a starter in accordance with IEC 947. If a different value is<br />
specified (such as reduced I e<br />
in motors with a coolant temperature<br />
higher than 40°C or a site altitude >2000 m above M.S.L.), the<br />
rated operating current I e<br />
must be adjusted.<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />
F42 Discount Schedule A-1
Dimensions<br />
KTA3-100 <strong>Motor</strong> <strong>Circuit</strong> Controller<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />
• Dimensions are shown in millimeters (inches).<br />
• Dimensions are not intended to be used for<br />
manufacturing purposes.<br />
KTA3-100 <strong>Motor</strong> <strong>Circuit</strong> Controller<br />
F<br />
<strong>Motor</strong> <strong>Circuit</strong><br />
<strong>Controllers</strong><br />
KTA3<br />
Discount Schedule A-1<br />
F43
F<br />
<strong>Motor</strong> <strong>Circuit</strong><br />
<strong>Controllers</strong><br />
Ecom<br />
Ecombo and<br />
EcomboPlus<br />
<strong>Starters</strong><br />
Save space,<br />
save money<br />
in individual or<br />
multi-motor<br />
starter applications<br />
The Ecombo starter line combines a KTA7 selfprotected<br />
Type E combination controller with a<br />
CA7 contactor to form a cost effective compact<br />
alternative to traditional combination starters.<br />
R<br />
Sprecher + Schuh’s new Ecombo and<br />
EcomboPlus starters are the compact<br />
alternative to larger and higher priced<br />
combination starters. Both models<br />
consist of a KTA7 <strong>Motor</strong> <strong>Circuit</strong><br />
Controller (UL / CSA listed as a<br />
Type E, self-protected combination<br />
starter), and a CA7 or CA4 contactor<br />
which provides remote operation.<br />
Whether used as a standalone starter<br />
or in multi-motor starter applications,<br />
Ecombo and EcomboPlus starters save<br />
significant panel space and dollars<br />
over conventional combination starter<br />
alternatives.<br />
Control and protection for<br />
most industrial applications<br />
The Ecombo starter line covers motors<br />
to 15HP (@460/600V), while<br />
providing current limiting short circuit<br />
protection to 65kA. Class 10 thermal<br />
overload protection is also assured with<br />
a very accurate current adjustment setting<br />
which is factory calibrated to the<br />
smallest and largest current the unit<br />
can handle. A “differential tripping”<br />
mechanism also provides accelerated<br />
tripping under single phase conditions<br />
(see illustration on page F3). Ecombo<br />
starters may be selected as Type 2 Coordinated<br />
per IEC 60947-4-1, U250E<br />
or UL Construction Type E or F.<br />
The Ecombo starter…<br />
Ecombo starters come standard with<br />
a KTA7 <strong>Motor</strong> <strong>Circuit</strong> Controller<br />
connected to Sprecher + Schuh’s CA7<br />
contactor (or CA4 mini contactor)<br />
through a specially designed connection<br />
module. The unit is DIN-rail<br />
mounted. Contactor coil connections<br />
are at the bottom of the starter to provide<br />
attractive and cost effective panel<br />
wiring. Ecombo starters may also be<br />
purchased with just three parts and assembled<br />
by the user to further increase<br />
economy.<br />
Ecombo starter<br />
EcomboPlus starter<br />
EcomboPlus…<br />
the complete solution<br />
The EcomboPlus starter is factory assembled<br />
on a special socket base that<br />
provides support and allows the starter<br />
to be mounted on one or two DINrails<br />
or screw mounted. Each starter<br />
comes standard with a front mounted<br />
auxiliary trip contact that is pre-wired<br />
to a built-in terminal block at the bottom<br />
of the unit. Contactor coil connections<br />
are also at the bottom of the<br />
starter to provide attractive and cost<br />
effective panel wiring.<br />
Reduce panel size,<br />
complexity and cost<br />
Because <strong>KT7</strong> <strong>Motor</strong> <strong>Circuit</strong> <strong>Controllers</strong><br />
are UL listed as self-protected<br />
combination starters, NEC / CEC<br />
group motor rules are simplified<br />
substantially. In many cases, only a<br />
non-fused switch is required for panel<br />
disconnect. See “Methods of Applying<br />
<strong>KT7</strong> <strong>Motor</strong> <strong>Circuit</strong> <strong>Controllers</strong>”<br />
in this publication, which explains<br />
applying <strong>KT7</strong>s in multi-motor starter<br />
applications.<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />
F44
Catalog Number Coding<br />
CL4 and CL7 Ecombo / CK7 EcomboPlus<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />
Starter Type<br />
EcomboPlus Starter with CA7<br />
CK7<br />
CKU7<br />
2 component DOL Starter<br />
2 component REV Starter<br />
Ecombo Starter with CA7<br />
CL7<br />
CLU7<br />
2 component DOL Starter<br />
2 component REV Starter<br />
Ecombo Starter with CA4<br />
CL4<br />
CLU4<br />
T<br />
2 component DOL Starter<br />
2 component REV Starter<br />
Add “T” for 3 component starter<br />
Contactor<br />
Series<br />
Series CA7 ➊<br />
9(C)<br />
12(C)<br />
16(C)<br />
23(C)<br />
30(C)<br />
37(C)<br />
43(C)<br />
60(D)<br />
72(D)<br />
85(D)<br />
Series CA4<br />
9(C)<br />
Aux.<br />
Contact<br />
01 1 NC<br />
10 1 NO<br />
11 1 NO + 1 NC<br />
20 2 NO<br />
22 2 NO + 2 NC<br />
Code<br />
Control Voltage*<br />
AC Voltage<br />
24Z 24V 50/60Hz<br />
120 110V 50Hz / 120V 60Hz<br />
208 208V 60Hz<br />
220W 208…240V 60Hz<br />
277 240V 50Hz / 277V 60Hz<br />
380 380…400V 50Hz / 440V 60Hz<br />
480 440V 50Hz / 480V 60Hz<br />
600 550V 50Hz / 600V 60Hz<br />
Code<br />
12D<br />
24D<br />
24DD<br />
48D<br />
110D<br />
220D<br />
DC Voltage<br />
12V<br />
24V<br />
24V with diode<br />
48V<br />
110V<br />
220V<br />
* Other control voltages available<br />
CL7 - 9 - 10 - 24Z - AS 0.25A - A01<br />
<strong>Circuit</strong> Breaker Type<br />
KT..7<br />
A…<br />
B…<br />
C…<br />
…S<br />
…H<br />
<strong>Motor</strong> Protection<br />
Starter Protection<br />
High Inrush Protection<br />
Standard Performance<br />
High Performance<br />
➊ (C) and (D) designations indicate DC coil.<br />
This illustration is for reference only.<br />
Turn to the appropriate page to determine<br />
specific catalog number & pricing.<br />
Adj. Range<br />
0.16A 0.1…0.16A<br />
0.25A 0.16…0.25A<br />
0.4A 0.25…0.4A<br />
0.63A 0.4…0.63A<br />
1.0A 0.63…1.0A<br />
1.6A 1.0…1.6A<br />
2.5A 1.6…2.5A<br />
4.0A 2.5…4.0A<br />
6.3A 4.0…6.3A<br />
10A 6.3…10A<br />
16A 10…16A<br />
20A 16…20A<br />
25A 20…25A<br />
32A 25…32A<br />
45A 32…45A<br />
Auxiliaries + Trip Contacts<br />
X<br />
A10<br />
A01<br />
A11<br />
A20<br />
T10A01<br />
T10A10<br />
No auxiliary contacts<br />
Aux. Contact 1 NO<br />
Aux. Contact 1 NC<br />
Aux. Contact 1 NO + 1 NC<br />
Aux. Contact 2 NO<br />
1 NO Trip + 1 NC Aux. Contact<br />
1 NO Trip + 1 NO Aux. Contact<br />
Option(s)<br />
For complete listing of<br />
Options Codes, refer to<br />
Modifications page in<br />
this section.<br />
F<br />
<strong>Motor</strong> <strong>Circuit</strong><br />
<strong>Controllers</strong><br />
Ecom<br />
Discount Schedule A-1<br />
F45
Ecombo <strong>Starters</strong><br />
Series CL4<br />
F<br />
<strong>Motor</strong> <strong>Circuit</strong><br />
<strong>Controllers</strong><br />
CL4<br />
Non-Reversing Ecombo <strong>Starters</strong> with AC Coil, Series CA4 Contactor<br />
Thermal Trip<br />
[A]<br />
Non-Reversing Ecombo <strong>Starters</strong> with DC Coil, Series CA4 Contactor<br />
AC Coil Codes (✱)<br />
A.C.<br />
Coil Code<br />
Magnetic Trip<br />
[A]<br />
Voltage Range<br />
50 Hz 60 Hz<br />
24 24V 24V<br />
120 110V 110…120V<br />
240 220…230V 230…240V<br />
277 240V 277V<br />
380 400V-415V 380…400V<br />
Index<br />
➊<br />
Typical Three Phase [HP]<br />
200V 230V 460V 575V Catalog Number ➋ Price<br />
0.10...0.16 2.1 101 ~ ~ ~ ~ CL4-9-10-✱-AS0.16A-X 243<br />
0.16...0.25 3.3 102 ~ ~ ~ ~ CL4-9-10-✱-AS0.25A-X 243<br />
0.25...0.40 5.2 103 ~ ~ ~ ~ CL4-9-10-✱-AS0.4A-X 243<br />
0.40...0.63 8.2 104 ~ ~ ~ ~ CL4-9-10-✱-AS0.63A-X 263<br />
0.63...1 13 105 ~ ~ 1/2 3/4 CL4-9-10-✱-AS1A-X 263<br />
1...1.6 21 106 ~ ~ 3/4 1 CL4-9-10-✱-AS1.6A-X 263<br />
1.6...2.5 33 107 1/2 1/2 1-1/2 2 CL4-9-10-✱-AS2.5A-X 263<br />
2.5...4 52 108 1 1 3 3 CL4-9-10-✱-AS4.0A-X 263<br />
4...6.3 82 109 1-1/2 2 3 5 CL4-9-10-✱-AS6.3A-X 271<br />
6.3...10 130 110 3 3 5 5 CL4-9-10-✱-AS10A-X 271<br />
10…16 208 111 3 3 7-1/2 10 CL4-12-10-✱-AS16A-X 313<br />
Thermal Trip<br />
[A]<br />
Magnetic Trip<br />
[A]<br />
Index<br />
➊<br />
Typical Three Phase [HP]<br />
200V 230V 460V 575V Catalog Number ➋ Price<br />
0.10...0.16 2.1 101 ~ ~ ~ ~ CL4-9C-10-✱-AS0.16A-X 254<br />
0.16...0.25 3.3 102 ~ ~ ~ ~ CL4-9C-10-✱-AS0.25A-X 254<br />
0.25...0.40 5.2 103 ~ ~ ~ ~ CL4-9C-10-✱-AS0.4A-X 254<br />
0.40...0.63 8.2 104 ~ ~ ~ ~ CL4-9C-10-✱-AS0.63A-X 274<br />
0.63...1 13 105 ~ ~ 1/2 3/4 CL4-9C-10-✱-AS1A-X 274<br />
1...1.6 21 106 ~ ~ 3/4 1 CL4-9C-10-✱-AS1.6A-X 274<br />
1.6...2.5 33 107 1/2 1/2 1-1/2 2 CL4-9C-10-✱-AS2.5A-X 274<br />
2.5...4 52 108 1 1 3 3 CL4-9C-10-✱-AS4.0A-X 274<br />
4...6.3 82 109 1-1/2 2 3 5 CL4-9C-10-✱-AS6.3A-X 282<br />
6.3...10 130 110 3 3 5 5 CL4-9C-10-✱-AS10A-X 282<br />
10…16 208 111 3 3 7-1/2 10 CL4-12C-10-✱-AS16A-X 324<br />
Ordering Instructions<br />
Specify Catalog Number<br />
Replace (✱) with Coil Code<br />
DC Coil Codes (✱)<br />
D.C.<br />
Coil Code<br />
24D<br />
48D<br />
110D<br />
220D<br />
See Coil Code table on<br />
this page for codes.<br />
Voltage<br />
24V<br />
110V<br />
220…230V<br />
240V<br />
Includes:<br />
• KTA7-25S (Standard Interrupting<br />
Capacity) <strong>Motor</strong> Controller<br />
• CA4 Contactor<br />
• Connecting Module<br />
(Cat.# <strong>KT7</strong>-25S-PEM12)<br />
• Terminal Adaptor for Type E<br />
Applications (Cat.# <strong>KT7</strong>-25-TE)<br />
• Can mount on one DIN-rail<br />
Horsepower ratings shown in the tables are for reference only.<br />
The final selection of the manual starter depends on the actual<br />
motor full load current and service factor.<br />
• For motor with service factor less than 1.15. Use motor nameplate full load<br />
current times 0.9 and choose the motor starter with the appropriate current<br />
range. Example: <strong>Motor</strong> F.L.C. = 4.2A; S.F. = 1.0. – 4.2A x 0.9 = 3.78A.<br />
Select Catalog Number KTA7-25S-4.0A.<br />
➊ KAIC Assembly Rating Index. See pages F50-51 for Application Rating Guide.<br />
➋ Does not include auxiliary contacts. See Factory Options on page F49 for additional<br />
auxiliary contact configurations.<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />
F46<br />
Discount Schedule A-1
Reversing Ecombo <strong>Starters</strong><br />
Series CLU4<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />
Reversing Ecombo <strong>Starters</strong> with AC Coil, Series CA4 Contactor<br />
Thermal Trip<br />
[A]<br />
Magnetic Trip<br />
[A]<br />
AC Coil Codes (✱)<br />
Index<br />
➊<br />
Typical Three Phase [HP]<br />
200V 230V 460V 575V Catalog Number ➋ Price<br />
0.10...0.16 2.1 101 ~ ~ ~ ~ CLU4-9-02-✱-AS0.16A-X 322<br />
0.16...0.25 3.3 102 ~ ~ ~ ~ CLU4-9-02-✱-AS0.25A-X 322<br />
0.25...0.40 5.2 103 ~ ~ ~ ~ CLU4-9-02-✱-AS0.4A-X 322<br />
0.40...0.63 8.2 104 ~ ~ ~ ~ CLU4-9-02-✱-AS0.63A-X 342<br />
0.63...1 13 105 ~ ~ 1/2 3/4 CLU4-9-02-✱-AS1A-X 342<br />
1...1.6 21 106 ~ ~ 3/4 1 CLU4-9-02-✱-AS1.6A-X 342<br />
1.6...2.5 33 107 1/2 1/2 1-1/2 2 CLU4-9-02-✱-AS2.5A-X 342<br />
2.5...4 52 108 1 1 3 3 CLU4-9-02-✱-AS4.0A-X 342<br />
4...6.3 82 109 1-1/2 2 3 5 CLU4-9-02-✱-AS6.3A-X 358<br />
6.3...10 130 110 3 3 5 5 CLU4-9-02-✱-AS10A-X 358<br />
10…16 208 111 3 3 7-1/2 10 CLU4-12-02-✱-AS16A-X 420<br />
A.C.<br />
Coil Code<br />
Voltage Range<br />
50 Hz 60 Hz<br />
24 24V 24V<br />
120 110V 110…120V<br />
240 220…230V 230…240V<br />
277 240V 277V<br />
380 400V-415V 380…400V<br />
Ordering Instructions<br />
Specify Catalog Number<br />
Replace (✱) with Coil Code<br />
See Coil Code table on<br />
this page for codes.<br />
Horsepower ratings shown in the tables are for reference only.<br />
The final selection of the manual starter depends on the actual<br />
motor full load current and service factor.<br />
• For motor with service factor less than 1.15. Use motor nameplate full load<br />
current times 0.9 and choose the motor starter with the appropriate current<br />
range. Example: <strong>Motor</strong> F.L.C. = 4.2A; S.F. = 1.0. – 4.2A x 0.9 = 3.78A.<br />
Select Catalog Number KTA7-25S-4.0A.<br />
Includes:<br />
• KTA7-25S (Standard Interrupting<br />
Capacity) <strong>Motor</strong> Controller<br />
• Two CA4 Contactors<br />
• Connecting Module<br />
(Cat.# <strong>KT7</strong>-25S-PEM12)<br />
• Terminal Adaptor for Type E Applications<br />
(Cat.# <strong>KT7</strong>-25-TE)<br />
• Reversing Power Wiring Kit<br />
(Cat.# KCR4)<br />
• Can mount on one DIN-rail<br />
➊ KAIC Assembly Rating Index. See pages F50-51 for Application Rating Guide.<br />
➋ Does not include auxiliary contacts. See Factory Options on page F49 for additional<br />
auxiliary contact configurations.<br />
F<br />
<strong>Motor</strong> <strong>Circuit</strong><br />
<strong>Controllers</strong><br />
CL4<br />
Discount Schedule A-1<br />
F47
Ecombo <strong>Starters</strong><br />
Series CL7<br />
F<br />
<strong>Motor</strong> <strong>Circuit</strong><br />
<strong>Controllers</strong><br />
CL4<br />
Non-Reversing Ecombo <strong>Starters</strong> with AC Coil, Series CA7 Contactor ➌<br />
Thermal Trip<br />
[A]<br />
Coil Codes (✱) ➋<br />
Magnetic Trip<br />
[A]<br />
Index<br />
➊<br />
Typical Three Phase [HP]<br />
200V 230V 460V 575V<br />
Catalog Number ➋<br />
Price<br />
KTA7-25S — Standard Interrupting Capacity<br />
0.10...0.16 2.1 51 ~ ~ ~ ~ CL7-9-10-✱-AS0.16A-A10 255<br />
0.16...0.25 3.3 52 ~ ~ ~ ~ CL7-9-10-✱-AS0.25A-A10 255<br />
0.25...0.40 5.2 53 ~ ~ ~ ~ CL7-9-10-✱-AS0.4A-A10 255<br />
0.40...0.63 8.2 54 ~ ~ ~ ~ CL7-9-10-✱-AS0.63A-A10 275<br />
0.63...1 13 55 ~ ~ 1/2 3/4 CL7-9-10-✱-AS1A-A10 275<br />
1...1.6 21 56 ~ ~ 1 1 CL7-9-10-✱-AS1.6A-A10 275<br />
1.6...2.5 33 57 1/2 3/4 1-1/2 2 CL7-9-10-✱-AS2.5A-A10 275<br />
2.5...4 52 58 1 1 3 3 CL7-9-10-✱-AS4.0A-A10 275<br />
4...6.3 82 59 1-1/2 2 5 5 CL7-9-10-✱-AS6.3A-A10 275<br />
6.3...10 130 60 3 3 7-1/2 10 CL7-12-10-✱-AS10A-A10 295<br />
10...16 208 61 3 5 10 15 CL7-16-10-✱-AS16A-A10 327<br />
14.5...20 260 64 5 7-1/2 15 15 CL7-23-10-✱-AS20A-A10 340<br />
18.5...25 325 65 5 7-1/2 15 15 CL7-23-10-✱-AS25A-A10 340<br />
KTA7-25H — High Interrupting Capacity<br />
1.6...2.5 33 66 1/2 3/4 1-1/2 2 CL7-9-10-✱-AH2.5A-A10 313<br />
2.5...4 52 68 1 1 3 3 CL7-9-10-✱-AH4.0A-A10 313<br />
4...6.3 82 70 1-1/2 2 5 5 CL7-9-10-✱-AH6.3A-A10 313<br />
6.3...10 130 72 3 3 7-1/2 10 CL7-12-10-✱-AH10A-A10 359<br />
10...16 208 74 3 5 10 15 CL7-16-10-✱-AH16A-A10 370<br />
14.5...20 260 76 5 7-1/2 15 15 CL7-23-10-✱-AH20A-A10 383<br />
18...25 325 78 5 7-1/2 15 15 CL7-23-10-✱-AH25A-A10 383<br />
A.C.<br />
Coil Code<br />
Voltage Range<br />
50 Hz 60 Hz<br />
24Z 24V 24V<br />
120 110V 120V<br />
208 ~ 208V<br />
220W ~ 208V-240V<br />
240 220V 240V<br />
277 240V 277V<br />
380 380...400V 440V<br />
480 440V 480V<br />
600 550V 600V<br />
Ordering Instructions<br />
Specify Catalog Number<br />
Replace (✱) with Coil Code<br />
Horsepower ratings shown in the tables are for reference only.<br />
The final selection of the manual starter depends on the actual<br />
motor full load current and service factor.<br />
• For motor with service factor less than 1.15. Use motor nameplate full load<br />
current times 0.9 and choose the motor starter with the appropriate current<br />
range. Example: <strong>Motor</strong> F.L.C. = 4.2A; S.F. = 1.0. – 4.2A x 0.9 = 3.78A.<br />
Select Catalog Number KTA7-25S-4.0A.<br />
See Coil Code table on<br />
this page for codes.<br />
Includes:<br />
• <strong>KT7</strong> <strong>Motor</strong> Controller with 1 NO<br />
Auxiliary Contact<br />
• CA7 Contactor (AC)<br />
• Connecting Module<br />
(Cat.# <strong>KT7</strong>-25[S or H]-PEC23)<br />
• Terminal Adaptor for Type E<br />
Applications (Cat.# <strong>KT7</strong>-25-TE)<br />
• Can mount on one DIN-rail<br />
➊ KAIC Assembly Rating Index. See pages F50-51 for Application Rating Guide.<br />
➋ Other voltages available, see Section A in this catalog. Nonstandard coil voltages<br />
not listed here must be ordered and installed separately as renewal parts.<br />
➌ CL7-30, 37 & 43 not shown because the components must be unassembled to<br />
mount them on two DIN-rails.<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />
F48<br />
Discount Schedule A-1
Reversing Ecombo <strong>Starters</strong><br />
Series CLU7<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />
Reversing Ecombo <strong>Starters</strong> with AC Coil, Series CA7 Contactor ➌<br />
Thermal Trip<br />
[A]<br />
Magnetic<br />
Trip [A]<br />
Coil Codes (✱) ➋<br />
Index<br />
➊<br />
Typical Three Phase [HP]<br />
200V 230V 460V 575V<br />
Catalog Number ➋<br />
Price<br />
KTA7-25S — Standard Interrupting Capacity<br />
0.10...0.16 2.1 51 ~ ~ ~ ~ CLU7-9-22-✱-AS0.16A-A10 386<br />
0.16...0.25 3.3 52 ~ ~ ~ ~ CLU7-9-22-✱-AS0.25A-A10 386<br />
0.25...0.40 5.2 53 ~ ~ ~ ~ CLU7-9-22-✱-AS0.4A-A10 386<br />
0.40...0.63 8.2 54 ~ ~ ~ ~ CLU7-9-22-✱-AS0.63A-A10 406<br />
0.63...1 13 55 ~ ~ 1/2 3/4 CLU7-9-22-✱-AS1A-A10 406<br />
1...1.6 21 56 ~ ~ 1 1 CLU7-9-22-✱-AS1.6A-A10 406<br />
1.6...2.5 33 57 1/2 3/4 1-1/2 2 CLU7-9-22-✱-AS2.5A-A10 406<br />
2.5...4 52 58 1 1 3 3 CLU7-9-22-✱-AS4.0A-A10 406<br />
4...6.3 82 59 1-1/2 2 5 5 CLU7-9-22-✱-AS6.3A-A10 406<br />
6.3...10 130 60 3 3 7-1/2 10 CLU7-12-22-✱-AS10A-A10 445<br />
10...16 208 61 3 5 10 15 CLU7-16-22-✱-AS16A-A10 490<br />
14.5...20 260 64 5 7-1/2 15 15 CLU7-23-22-✱-AS20A-A10 515<br />
18.5...25 325 65 5 7-1/2 15 15 CLU7-23-22-✱-AS25A-A10 515<br />
KTA7-25H — High Interrupting Capacity<br />
1.6...2.5 33 66 1/2 3/4 1-1/2 2 CLU7-9-22-✱-AH2.5A-A10 443<br />
2.5...4 52 68 1 1 3 3 CLU7-9-22-✱-AH4.0A-A10 443<br />
4...6.3 82 70 1-1/2 2 5 5 CLU7-9-22-✱-AH6.3A-A10 443<br />
6.3...10 130 72 3 3 7-1/2 10 CLU7-12-22-✱-AH10A-A10 509<br />
10...16 208 74 3 5 10 15 CLU7-16-22-✱-AH16A-A10 533<br />
14.5...20 260 76 5 7-1/2 15 15 CLU7-23-22-✱-AH20A-A10 558<br />
18...25 325 78 5 7-1/2 15 15 CLU7-23-22-✱-AH25A-A10 558<br />
A.C.<br />
Coil Code<br />
Voltage Range<br />
50 Hz 60 Hz<br />
24Z 24V 24V<br />
120 110V 120V<br />
208 ~ 208V<br />
220W ~ 208V-240V<br />
240 220V 240V<br />
277 240V 277V<br />
380 380...400V 440V<br />
480 440V 480V<br />
600 550V 600V<br />
Ordering Instructions<br />
Specify Catalog Number<br />
Replace (✱) with Coil Code<br />
Horsepower ratings shown in the tables are for reference only.<br />
The final selection of the manual starter depends on the actual<br />
motor full load current and service factor.<br />
• For motor with service factor less than 1.15. Use motor nameplate full load<br />
current times 0.9 and choose the motor starter with the appropriate current<br />
range. Example: <strong>Motor</strong> F.L.C. = 4.2A; S.F. = 1.0. – 4.2A x 0.9 = 3.78A.<br />
Select Catalog Number KTA7-25S-4.0A.<br />
See Coil Code table on<br />
this page for codes.<br />
Includes:<br />
• <strong>KT7</strong> <strong>Motor</strong> Controller with 1 NO<br />
Auxiliary Contact<br />
• Two CA7 Contactors (AC)<br />
• Connecting Module<br />
(Cat.# <strong>KT7</strong>-25[S or H]-PEC23)<br />
• Terminal Adaptor for Type E Applications<br />
(Cat.# <strong>KT7</strong>-25-TE)<br />
• Reversing Power Wiring Kit<br />
(Cat.# CAUT7-PW23)<br />
• <strong>Electric</strong>al / Mechanical Interlock<br />
(Cat.# CM7-02)<br />
• Can mount on one DIN-rail<br />
➊ KAIC Assembly Rating Index. See pages F50-51 for Application Rating Guide.<br />
➋ Other voltages available, see Section A in this catalog. Nonstandard coil voltages<br />
not listed here must be ordered and installed separately as renewal parts.<br />
➌ CLU7-30, 37 & 43 not shown because the components must be unassembled to<br />
mount them on two DIN-rails.<br />
F<br />
<strong>Motor</strong> <strong>Circuit</strong><br />
<strong>Controllers</strong><br />
CL4<br />
Discount Schedule A-1<br />
F49
EcomboPlus <strong>Starters</strong>, AC Coil<br />
Series CK7<br />
F<br />
<strong>Motor</strong> <strong>Circuit</strong><br />
<strong>Controllers</strong><br />
CK7<br />
Non-Reversing EcomboPlus <strong>Starters</strong> with AC Coil, Series CA7 Contactors<br />
Thermal Trip Magnetic Trip Index<br />
Typical Three Phase [HP]<br />
[A]<br />
[A] ➊ 200V 230V 460V 575V Catalog Number ➋ Price<br />
KTA7-25S — Standard Interrupting Capacity<br />
0.10...0.16 2.1 1 ~ ~ ~ ~ CK7-9-10-✱-AS0.16A-A11 351<br />
0.16...0.25 3.3 2 ~ ~ ~ ~ CK7-9-10-✱-AS0.25A-A11 351<br />
0.25...0.40 5.2 3 ~ ~ ~ ~ CK7-9-10-✱-AS0.4A-A11 351<br />
0.40...0.63 8.2 4 ~ ~ ~ ~ CK7-9-10-✱-AS0.63A-A11 371<br />
0.63...1 13 5 ~ ~ 1/2 3/4 CK7-9-10-✱-AS1A-A11 371<br />
1...1.6 21 6 ~ ~ 1 1 CK7-9-10-✱-AS1.6A-A11 371<br />
1.6...2.5 33 7 1/2 3/4 1-1/2 2 CK7-9-10-✱-AS2.5A-A11 371<br />
2.5...4 52 8 1 1 3 3 CK7-9-10-✱-AS4A-A11 371<br />
4...6.3 82 9 1-1/2 2 5 5 CK7-9-10-✱-AS6.3A-A11 371<br />
6.3...10 130 10 3 3 7-1/2 10 CK7-12-10-✱-AS10A-A11 392<br />
10...16 208 11 3 5 10 15 CK7-16-10-✱-AS16A-A11 426<br />
14.5...20 260 14 5 7-1/2 15 15 CK7-23-10-✱-AS20A-A11 439<br />
18.5...25 325 15 5 7-1/2 15 15 CK7-23-10-✱-AS25A-A11 439<br />
KTA7-25H — High Interrupting Capacity<br />
1.6...2.5 33 16 1/2 3/4 1-1/2 2 CK7-9-10-✱-AH2.5A-A11 411<br />
2.5...4 52 18 1 1 3 3 CK7-9-10-✱-AH4A-A11 411<br />
4...6.3 82 20 1-1/2 2 5 5 CK7-9-10-✱-AH6.3A-A11 411<br />
6.3...10 130 22 3 3 7-1/2 10 CK7-12-10-✱-AH10A-A11 459<br />
10...16 208 24 3 5 10 15 CK7-16-10-✱-AH16A-A11 471<br />
14.5...20 260 26 5 7-1/2 15 15 CK7-23-10-✱-AH20A-A11 484<br />
18...25 325 28 5 7-1/2 15 15 CK7-23-10-✱-AH25A-A11 484<br />
KTA7-45H — High Interrupting Capacity<br />
6.3…10 130 30 3 3 7-1/2 10 CK7-30-11-✱-AH10A-A11 632<br />
10....16 208 31 3 5 10 15 CK7-30-11-✱-AH16A-A11 632<br />
14.5...20 260 32 5 7-1/2 15 15 CK7-30-11-✱-AH20A-A11 632<br />
18…25 325 33 5 7-1/2 15 15 CK7-30-11-✱-AH25A-A11 632<br />
23…32 416 34 7-1/2 10 20 25 CK7-30-11-✱-AH32A-A11 650<br />
32…45 585 35 10 10 25 30 CK7-37-11-✱-AH45A-A11 689<br />
32…45 585 36 10 15 30 30 CK7-43-11-✱-AH45A-A11 696<br />
Coil Codes (✱) ➍<br />
A.C.<br />
Coil Code<br />
Voltage Range<br />
50 Hz 60 Hz<br />
24Z 24V 24V<br />
120 110V 120V<br />
208 ~ 208V<br />
220W ~ 208V-240V<br />
240 220V 240V<br />
277 240V 277V<br />
380 380...400V 440V<br />
480 440V 480V<br />
600 550V 600V<br />
Ordering Instructions<br />
Specify Catalog Number<br />
Replace (✱) with Coil Code<br />
Horsepower ratings shown in the tables are for reference only.<br />
The final selection of the manual starter depends on the actual<br />
motor full load current and service factor.<br />
• For motor with service factor less than 1.15. Use motor nameplate full load<br />
current times 0.9 and choose the motor starter with the appropriate current<br />
range. Example: <strong>Motor</strong> F.L.C. = 4.2A; S.F. = 1.0. – 4.2A x 0.9 = 3.78A.<br />
Select Catalog Number KTA7-25S-4.0A.<br />
See Coil Code table on<br />
this page for codes.<br />
Description ➌<br />
The EcomboPlus starter is a<br />
factory assembly consisting of a <strong>KT7</strong><br />
controller with 1 NO - 1 NC auxiliary<br />
and a CA7 contactor housed in a<br />
specially designed frame. All control<br />
wiring is pre-wired and brought out<br />
to a built-in terminal block, integral<br />
to the mounting frame. Terminal<br />
Adaptor (Cat.# <strong>KT7</strong>-25[45]-TE) is also<br />
included for Type E applications.<br />
➊ KAIC Assembly Rating Index. See pages F50-51 for Application Rating Guide.<br />
➋ 1 NO + 1 NC auxiliary contact on <strong>KT7</strong> is standard. 1 NO auxiliary contact on CA7<br />
contactor is standard. See Factory Options on page F49 for additional auxiliary<br />
contact configurations.<br />
➌ Mounting Options:<br />
• Screw Fixing<br />
• Snap Fixing on (1) or (2) 35 mm DIN Rails<br />
• Snap Fixing on (1) 75 mm DIN Rail<br />
➍ Other voltages available, see Section A in this catalog. Nonstandard coil voltages<br />
not listed here must be ordered and installed separately as renewal parts.<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />
F50<br />
Discount Schedule A-1
Reversing EcomboPlus <strong>Starters</strong>, AC Coil<br />
Series CKU7<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />
Reversing EcomboPlus <strong>Starters</strong> with AC Coil, Series CA7 Contactors<br />
Thermal Trip<br />
[A]<br />
Coil Codes (✱) ➍<br />
Magnetic Trip<br />
[A]<br />
Typical Three Phase [HP]<br />
Index<br />
➊ 200V 230V 460V 575V Catalog Number ➋<br />
KTA7-25S — Standard Interrupting Capacity<br />
0.10...0.16 2.1 1 ~ ~ ~ ~ CKU7-9-22-✱-AS0.16A-A11 531<br />
0.16...0.25 3.3 2 ~ ~ ~ ~ CKU7-9-22-✱-AS0.25A-A11 531<br />
0.25...0.40 5.2 3 ~ ~ ~ ~ CKU7-9-22-✱-AS0.4A-A11 531<br />
0.40...0.63 8.2 4 ~ ~ ~ ~ CKU7-9-22-✱-AS0.63A-A11 531<br />
0.63...1 13 5 ~ ~ 1/2 3/4 CKU7-9-22-✱-AS1A-A11 531<br />
1...1.6 21 6 ~ ~ 1 1 CKU7-9-22-✱-AS1.6A-A11 531<br />
1.6...2.5 33 7 1/2 3/4 1-1/2 2 CKU7-9-22-✱-AS2.5A-A11 531<br />
2.5...4 52 8 1 1 3 3 CKU7-9-22-✱-AS4.0A-A11 531<br />
4...6.3 82 9 1-1/2 2 5 5 CKU7-9-22-✱-AS6.3A-A11 551<br />
6.3...10 130 10 3 3 7-1/2 10 CKU7-12-22-✱-AS10A-A11 593<br />
10...16 208 11 3 5 10 15 CKU7-16-22-✱-AS16A-A11 639<br />
14.5...20 260 14 5 7-1/2 15 15 CKU7-23-22-✱-AS20A-A11 665<br />
18.5...25 325 15 5 7-1/2 15 15 CKU7-23-22-✱-AS25A-A11 665<br />
KTA7-25H — High Interrupting Capacity<br />
1.6...2.5 33 16 1/2 3/4 1-1/2 2 CKU7-9-22-✱-AH2.5A-A11 591<br />
2.5...4 52 18 1 1 3 3 CKU7-9-22-✱-AH4.0A-A11 591<br />
4...6.3 82 20 1-1/2 2 5 5 CKU7-9-22-✱-AH6.3A-A11 591<br />
6.3...10 130 22 3 3 7-1/2 10 CKU7-12-22-✱-AH10A-A11 659<br />
10...16 208 24 3 5 10 15 CKU7-16-22-✱-AH16A-A11 684<br />
14.5...20 260 26 5 7-1/2 15 15 CKU7-23-22-✱-AH20A-A11 710<br />
18...25 325 28 5 7-1/2 15 15 CKU7-23-22-✱-AH25A-A11 710<br />
Horsepower ratings shown in the tables are for reference only.<br />
The final selection of the manual starter depends on the actual<br />
motor full load current and service factor.<br />
• For motor with service factor less than 1.15. Use motor nameplate full load<br />
current times 0.9 and choose the motor starter with the appropriate current<br />
range. Example: <strong>Motor</strong> F.L.C. = 4.2A; S.F. = 1.0. – 4.2A x 0.9 = 3.78A.<br />
Select Catalog Number KTA7-25S-4.0A.<br />
A.C.<br />
Coil Code<br />
Voltage Range<br />
50 Hz 60 Hz<br />
24Z 24V 24V<br />
120 110V 120V<br />
208 ~ 208V<br />
220W ~ 208V-240V<br />
240 220V 240V<br />
277 240V 277V<br />
380 380...400V 440V<br />
480 440V 480V<br />
600 550V 600V<br />
Ordering Instructions<br />
Specify Catalog Number<br />
Replace (✱) with Coil Code<br />
See Coil Code table on<br />
this page for codes.<br />
Price<br />
Description ➌<br />
The EcomboPlus Reversing starter<br />
is a factory assembly consisting of<br />
a <strong>KT7</strong> controller with 1 NO - 1 NC<br />
auxiliary and reversing CA7 contactors<br />
housed in a specially designed<br />
frame. All control wiring is pre-wired<br />
and brought out to a built-in terminal<br />
block, integral to the mounting frame.<br />
A Reversing Power Wiring Kit (Cat.#<br />
CAUT7-PW23) is used to wire the reversing<br />
contactors. An electrical and<br />
mechanical interlock is also provided<br />
(Cat.# CM7-02), as well as a Terminal<br />
Adaptor (Cat.# <strong>KT7</strong>-25-TE) for Type E<br />
applications.<br />
➊ KAIC Assembly Rating Index. See pages F50-51 for Application Rating Guide.<br />
➋ 1 NO + 1 NC auxiliary contact on the <strong>KT7</strong> is standard. 2-NO auxiliary contacts<br />
on the CKU7 contactor and 2-NC auxiliary contacts on the CM7-02 interlock per<br />
reversing pair is standard. See Factory Options on page F49 for additional auxiliary<br />
contact configurations.<br />
➌ Mounting Options:<br />
• Screw Fixing<br />
• Snap Fixing on (1) or (2) 35 mm DIN Rails<br />
• Snap Fixing on (1) 75 mm DIN Rail<br />
➍ Other voltages available, see Section A in this catalog. Nonstandard coil voltages<br />
not listed here must be ordered and installed separately as renewal parts.<br />
F<br />
<strong>Motor</strong> <strong>Circuit</strong><br />
<strong>Controllers</strong><br />
CK7<br />
Discount Schedule A-1<br />
F51
EcomboPlus <strong>Starters</strong>, DC Coil<br />
Series CK7<br />
F<br />
<strong>Motor</strong> <strong>Circuit</strong><br />
<strong>Controllers</strong><br />
CK7<br />
Non-Reversing EcomboPlus <strong>Starters</strong> with DC Coil, Series CA7 Contactors<br />
Thermal Trip<br />
[A]<br />
Coil Codes (✱) ➍<br />
Magnetic Trip<br />
[A]<br />
Typical Three Phase [HP]<br />
Index<br />
➊ 200V 230V 460V 575V Catalog Number ➋<br />
KTA7-25S — Standard Interrupting Capacity<br />
0.10...0.16 2.1 1 ~ ~ ~ ~ CK7-9C-10-✱-AS0.16A-A11 384<br />
0.16...0.25 3.3 2 ~ ~ ~ ~ CK7-9C-10-✱-AS0.25A-A11 384<br />
0.25...0.40 5.2 3 ~ ~ ~ ~ CK7-9C-10-✱-AS0.4A-A11 384<br />
0.40...0.63 8.2 4 ~ ~ ~ ~ CK7-9C-10-✱-AS0.63A-A11 404<br />
0.63...1 13 5 ~ ~ 1/2 3/4 CK7-9C-10-✱-AS1A-A11 404<br />
1...1.6 21 6 ~ ~ 1 1 CK7-9C-10-✱-AS1.6A-A11 404<br />
1.6...2.5 33 7 1/2 3/4 1-1/2 2 CK7-9C-10-✱-AS2.5A-A11 404<br />
2.5...4 52 8 1 1 3 3 CK7-9C-10-✱-AS4.0A-A11 404<br />
4...6.3 82 9 1-1/2 2 5 5 CK7-9C-10-✱-AS6.3A-A11 404<br />
6.3...10 130 10 3 3 7-1/2 10 CK7-12C-10-✱-AS10A-A11 431<br />
10...16 208 11 3 5 10 15 CK7-16C-10-✱-AS16A-A11 467<br />
14.5...20 260 14 5 7-1/2 15 15 CK7-23C-10-✱-AS20A-A11 483<br />
18.5...25 325 15 5 7-1/2 15 15 CK7-23C-10-✱-AS25A-A11 483<br />
KTA7-25H — High Interrupting Capacity<br />
1.6...2.5 33 16 1/2 3/4 1-1/2 2 CK7-9C-10-✱-AH2.5A-A11 436<br />
2.5...4 52 18 1 1 3 3 CK7-9C-10-✱-AH4.0A-A11 436<br />
4...6.3 82 20 1-1/2 2 5 5 CK7-9C-10-✱-AH6.3A-A11 436<br />
6.3...10 130 22 3 3 7-1/2 10 CK7-12C-10-✱-AH10A-A11 490<br />
10...16 208 24 3 5 10 15 CK7-16C-10-✱-AH16A-A11 505<br />
14.5...20 260 26 5 7-1/2 15 15 CK7-23C-10-✱-AH20A-A11 527<br />
18...25 325 28 5 7-1/2 15 15 CK7-23C-10-✱-AH25A-A11 527<br />
KTA7-45H — High Interrupting Capacity<br />
6.3…10 130 30 3 3 7-1/2 10 CK7-30C-11-✱-AH10A-A11 698<br />
10....16 208 31 3 5 10 15 CK7-30C-11-✱-AH16A-A11 698<br />
14.5...20 260 32 5 7-1/2 15 15 CK7-30C-11-✱-AH20A-A11 698<br />
18…25 325 33 5 7-1/2 15 15 CK7-30C-11-✱-AH25A-A11 698<br />
23…32 416 34 7-1/2 10 20 25 CK7-30C-11-✱-AH32A-A11 735<br />
32…45 585 35 10 10 25 30 CK7-37C-11-✱-AH45A-A11 772<br />
32…45 585 36 10 15 30 30 CK7-43C-11-✱-AH45A-A11 785<br />
CK7-9C...43C<br />
D.C. Coil Code<br />
12D<br />
24D<br />
48D<br />
110D<br />
220D<br />
Voltage<br />
12V<br />
24V<br />
48V<br />
110V<br />
220V<br />
Ordering Instructions<br />
Specify Catalog Number<br />
Replace (✱) with Coil Code<br />
Price<br />
Horsepower ratings shown in the tables are for reference only.<br />
The final selection of the manual starter depends on the actual<br />
motor full load current and service factor.<br />
• For motor with service factor less than 1.15. Use motor nameplate full load<br />
current times 0.9 and choose the motor starter with the appropriate current<br />
range. Example: <strong>Motor</strong> F.L.C. = 4.2A; S.F. = 1.0. – 4.2A x 0.9 = 3.78A.<br />
Select Catalog Number KTA7-25S-4.0A.<br />
See Coil Code table on<br />
this page for codes.<br />
Description ➌<br />
The EcomboPlus starter is a factory<br />
assembly consisting of a <strong>KT7</strong><br />
controller with 1 NO - 1 NC auxiliary<br />
and a CA7 contactor housed in a<br />
specially designed frame. All control<br />
wiring is pre-wired and brought out<br />
to a built-in terminal block, integral<br />
to the mounting frame. Terminal<br />
Adaptor (Cat.# <strong>KT7</strong>-25[45]-TE) is also<br />
included for Type E applications.<br />
➊ KAIC Assembly Rating Index. See pages F50-51 for Application Rating Guide.<br />
➋ 1 NO + 1 NC auxiliary contact on the <strong>KT7</strong> is standard. 2-NO auxiliary contacts<br />
on the CAU7 contactor and 2-NC auxiliary contacts on the CM7-02 interlock per<br />
reversing pair is standard. See Factory Options on page F49 for additional auxiliary<br />
contact configurations.<br />
➌ Mounting Options:<br />
• Screw Fixing<br />
• Snap Fixing on (1) or (2) 35 mm DIN Rails<br />
• Snap Fixing on (1) 75 mm DIN Rail<br />
➍ Other voltages available, see Section A in this catalog. Nonstandard coil voltages<br />
not listed here must be ordered and installed separately as renewal parts.<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />
F52<br />
Discount Schedule A-1
Factory Options<br />
Series CK7<br />
CL4 and CL7 Modifications<br />
CK7 Modifications<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />
Modification<br />
Change Last<br />
Digit in Catalog<br />
Number to: ➊<br />
CL4 and CL7 Additions<br />
Add desired suffix AFTER auxiliary contact option code.<br />
Price<br />
<strong>KT7</strong> Auxiliary and Trip Contacts<br />
Auxiliary Contact 1 NO (CL4 only) A10 33<br />
Auxiliary Contact 1 NC A01 33<br />
Auxiliary Contact 1 NO + 1 NC A11 37<br />
Auxiliary Contact 2 NO A20 37<br />
1 NO Trip + 1 NC Auxiliary Contact T10A01 47<br />
1 NO Trip + 1 NO Auxiliary Contact T10A10 47<br />
Addition<br />
Add Suffix to<br />
Catalog Number: Price<br />
Accessories<br />
Electronic Interfaces (CA7) -JE 56<br />
Surge Suppressor RC (CA7) -R 32<br />
Surge Suppressor Varistor (CA7) -V 24<br />
Surge Suppressor Diode (CA7) -D 31<br />
Lockable Twist Knob (<strong>KT7</strong>) - Black -KN 16<br />
Lockable Twist Knob (<strong>KT7</strong>) - Red/Yellow -KRY 20<br />
Additional Contactor Auxiliaries (Side Mount)<br />
1 NC -S01 27<br />
1 NO -S10 27<br />
1 NO + 1 NC -S11 34<br />
2 NO -S20 34<br />
Additional Contactor Auxiliaries (Front Mount)<br />
1 NO + 1 NC -F11 34<br />
2 NO -F20 34<br />
2 NO + 2 NC -F22 34<br />
Additional <strong>KT7</strong> Auxiliaries (Side Mount)<br />
2 NC -AS02 47<br />
2 NO -AS20 47<br />
1 NO + 1 NC -AS11 47<br />
Additional <strong>KT7</strong> Trip Contacts (Side Mount)<br />
1 NO Thermal-Mag + 1 NO Mag Only -R00 56<br />
1 NO Thermal-Mag + 1 NC Mag Only -R01 56<br />
1 NC Thermal-Mag + 1 NO Mag Only -R10 56<br />
1 NC Thermal-Mag + 1 NC Mag Only -R11 56<br />
1 NO Mag Only + 1 NC Mag Only -M11 56<br />
➊ For CL4, change last digit “X” to one of the modifications listed. Example: Change<br />
CL4-9-10-✱-AS0.16A-X to CL4-9-10-✱-AS0.16A-A10. For CL7, change last digits<br />
“A10” to one of the modifications listed. Example: Change CL7-9-10- * -AS0.16A-<br />
A10 to CL7-9-10-✱-AS0.16A-A01.<br />
Modification<br />
Change Last Digits<br />
(A11) in Catalog<br />
Number to: ➊<br />
CK7 Additions<br />
Add desired suffix AFTER auxiliary contact option code.<br />
Price<br />
CK7 Auxiliary and Trip Contacts<br />
Auxiliary Contact 2 NO A20 31<br />
1 NO Trip + 1 NC Auxiliary Contact T10A01 10<br />
1 NO Trip + 1 NO Auxiliary Contact T10A10 10<br />
Addition<br />
Add Suffix to<br />
Catalog Number:<br />
Price<br />
Accessories<br />
Electronic Interfaces (CA7) -JE 56<br />
Surge Suppressor RC (CA7) -R 32<br />
Surge Suppressor Varistor (CA7) -V 24<br />
Surge Suppressor Diode (CA7) -D 31<br />
Socket and Plug for Control <strong>Circuit</strong> -SP 27<br />
Lockable Twist Knob (<strong>KT7</strong>) - Black -KN 16<br />
Lockable Twist Knob (<strong>KT7</strong>) - Red/Yellow -KRY 20<br />
Additional Contactor Auxiliaries (Side Mount)<br />
1 NC -S01 27<br />
1 NO -S10 27<br />
1 NO + 1 NC -S11 34<br />
2 NO -S20 34<br />
Additional <strong>KT7</strong> Auxiliaries (Side Mount)<br />
2 NC -AS02 47<br />
2 NO -AS20 47<br />
1 NO + 1 NC -AS11 47<br />
Additional <strong>KT7</strong> Trip Contacts (Side Mount)<br />
1 NO Thermal-Mag + 1 NO Mag Only -R00 56<br />
1 NO Thermal-Mag + 1 NC Mag Only -R01 56<br />
1 NC Thermal-Mag + 1 NO Mag Only -R10 56<br />
1 NC Thermal-Mag + 1 NC Mag Only -R11 56<br />
1 NO Mag Only+ 1 NC Mag Only -M11 56<br />
F<br />
<strong>Motor</strong> <strong>Circuit</strong><br />
<strong>Controllers</strong><br />
Ecom<br />
Discount Schedule A-1<br />
F53
Technical Information<br />
Short <strong>Circuit</strong> Ratings<br />
<strong>KT7</strong> Assembly – Application Rating Chart (Ratings are dependent on type of application)<br />
F<br />
<strong>Motor</strong> <strong>Circuit</strong><br />
<strong>Controllers</strong><br />
Rating<br />
Index<br />
Assembly<br />
Assembly Components<br />
<strong>Manual</strong> Controller<br />
or<br />
Group Installation<br />
480Y / 227V<br />
Combination<br />
<strong>Motor</strong> Controller<br />
(Type F)<br />
600Y / 347V<br />
Self-Protected<br />
Combination <strong>Motor</strong><br />
Controller (Type E)<br />
<strong>KT7</strong> Contactor 480V KAIC 600V KAIC Type 1 KAIC Type 2 KAIC Type 1 KAIC Type 2 KAIC Type E KAIC Type E KAIC<br />
CL4 / CLU4 UL Assembly<br />
101 CL4 / CLU4 KTA7-25S-0.16A CA4-9 65 47 65 65 47 ~ ~ ~<br />
102 CL4 / CLU4 KTA7-25S-0.25A CA4-9 65 47 65 65 47 ~ ~ ~<br />
103 CL4 / CLU4 KTA7-25S-0.4A CA4-9 65 47 65 65 47 ~ ~ ~<br />
104 CL4 / CLU4 KTA7-25S-0.63A CA4-9 65 47 65 65 47 ~ ~ ~<br />
105 CL4 / CLU4 KTA7-25S-1.0A CA4-9 65 47 65 65 47 ~ ~ ~<br />
106 CL4 / CLU4 KTA7-25S-1.6A CA4-9 65 47 65 65 47 ~ ~ ~<br />
107 CL4 / CLU4 KTA7-25S-2.5A CA4-9 65 30 65 ~ 30 ~ ~ ~<br />
108 CL4 / CLU4 KTA7-25S-4.0A CA4-9 65 30 65 ~ 30 ~ ~ ~<br />
109 CL4 / CLU4 KTA7-25S-6.3A CA4-9 65 ~ 65 ~ ~ ~ ~ ~<br />
110 CL4 / CLU4 KTA7-25S-10A CA4-9 65 ~ 65 ~ ~ ~ ~ ~<br />
111 CL4 / CLU4 KTA7-25S-16A CA4-12 30 ~ 30 ~ ~ ~ ~ ~<br />
CL7 / CLU7 UL Assembly<br />
51 CL7 / CLU7 KTA7-25S-0.16A CA7-9 65 47 65 65 47 47 65 47<br />
52 CL7 / CLU7 KTA7-25S-0.25A CA7-9 65 47 65 65 47 47 65 47<br />
53 CL7 / CLU7 KTA7-25S-0.4A CA7-9 65 47 65 65 47 47 65 47<br />
54 CL7 / CLU7 KTA7-25S-0.63A CA7-9 65 47 65 65 47 47 65 47<br />
55 CL7 / CLU7 KTA7-25S-1.0A CA7-9 65 47 65 65 47 47 65 47<br />
56 CL7 / CLU7 KTA7-25S-1.6A CA7-9 65 47 65 65 47 47 65 47<br />
57 CL7 / CLU7 KTA7-25S-2.5A CA7-9 65 30 65 65 30 10 65 ~<br />
58 CL7 / CLU7 KTA7-25S-4.0A CA7-9 65 30 65 ~ 30 ~ ~ ~<br />
59 CL7 / CLU7 KTA7-25S-6.3A CA7-9 65 30 65 ~ ~ ~ ~ ~<br />
60 CL7 / CLU7 KTA7-25S-10A CA7-12 65 30 65 ~ ~ ~ ~ ~<br />
61 CL7 / CLU7 KTA7-25S-16A CA7-16 30 30 30 ~ ~ ~ ~ ~<br />
62 CL7 / CLU7 KTA7-25H-4.0A CA7-23 65 30 65 ~ 30 ~ 65 30<br />
63 CL7 / CLU7 KTA7-25H-16A CA7-23 30 30 65 ~ ~ ~ ~ ~<br />
64 CL7 / CLU7 KTA7-25S-20A CA7-23 30 30 10 ~ ~ ~ ~ ~<br />
65 CL7 / CLU7 KTA7-25S-25A CA7-23 30 30 ~ ~ ~ ~ ~ ~<br />
66 CL7 / CLU7 KTA7-25H-2.5A CA7-9 65 30 65 65 30 ~ 65 ~<br />
67 CL7 / CLU7 KTA7-25H-2.5A CA7-23 65 30 65 65 30 30 65 30<br />
68 CL7 / CLU7 KTA7-25H-4.0A CA7-9 65 30 65 65 30 ~ ~ ~<br />
69 CL7 / CLU7 KTA7-25H-4.0A CA7-23 65 30 65 65 30 30 65 30<br />
70 CL7 / CLU7 KTA7-25H-6.3A CA7-9 65 30 65 65 30 ~ ~ ~<br />
71 CL7 KTA7-25H-6.3A CA7-30 65 30 65 65 30 30 65 30<br />
72 CL7 / CLU7 KTA7-25H-10A CA7-12 65 30 65 65 30 ~ ~ ~<br />
73 CL7 KTA7-25H-10A CA7-30 65 30 65 65 30 30 65 30<br />
74 CL7 / CLU7 KTA7-25H-16A CA7-16 65 30 65 65 30 ~ ~ ~<br />
75 CL7 KTA7-25H-16A CA7-30 65 30 65 65 30 30 65 30<br />
76 CL7 / CLU7 KTA7-25H-20A CA7-23 65 30 65 65 ~ ~ ~ ~<br />
77 CL7 KTA7-25H-20A CA7-30 65 30 65 65 ~ ~ 65 ~<br />
78 CL7 / CLU7 KTA7-25H-25A CA7-23 30 30 65 65 ~ ~ ~ ~<br />
79 CL7 KTA7-25H-25A CA7-30 65 30 65 65 30 30 65 30<br />
80 CL7 KTA7-45H-10A CA7-30 65 30 65 65 30 30 65 30<br />
81 CL7 KTA7-45H-16A CA7-30 65 30 65 65 30 30 65 30<br />
82 CL7 KTA7-45H-20A CA7-30 65 30 65 65 30 30 65 30<br />
83 CL7 KTA7-45H-25A CA7-30 65 30 65 65 30 30 65 30<br />
84 CL7 KTA7-45H-45A CA7-37 65 18 65 65 ~ ~ 65 ~<br />
85 CL7 KTA7-45H-45A CA7-45 65 18 65 65 ~ ~ 65 ~<br />
480Y /<br />
277V<br />
600Y /<br />
347V<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />
Ecom<br />
Gray type indicates non-cataloged assembly. Contact your<br />
Sprecher+ Schuh representative for information.<br />
F54<br />
Discount Schedule A-1
Technical Information<br />
Short <strong>Circuit</strong> Ratings<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />
<strong>KT7</strong> Assembly – Application Rating Chart (Ratings are dependent on type of application)<br />
Rating<br />
Index<br />
Assembly<br />
Assembly Components<br />
Gray type indicates non-cataloged assembly. Contact your<br />
Sprecher+ Schuh representative for information.<br />
<strong>Manual</strong> Controller<br />
or<br />
Group Installation<br />
480Y / 227V<br />
Combination<br />
<strong>Motor</strong> Controller<br />
(Type F)<br />
600Y / 347V<br />
Self-Protected<br />
Combination <strong>Motor</strong><br />
Controller (Type E)<br />
<strong>KT7</strong> Contactor 480V KAIC 600V KAIC Type 1 KAIC Type 2 KAIC Type 1 KAIC Type 2 KAIC Type E KAIC Type E KAIC<br />
CK7 / CKU7 UL Assembly<br />
1 CK7/CKU7 KTA7-25S-0.16A CA7-9 65 47 65 65 47 47 65 47<br />
2 CK7/CKU7 KTA7-25S-0.25A CA7-9 65 47 65 65 47 47 65 47<br />
3 CK7/CKU7 KTA7-25S-0.4A CA7-9 65 47 65 65 47 47 65 47<br />
4 CK7/CKU7 KTA7-25S-0.63A CA7-9 65 47 65 65 47 47 65 47<br />
5 CK7/CKU7 KTA7-25S-1.0A CA7-9 65 47 65 65 47 47 65 47<br />
6 CK7/CKU7 KTA7-25S-1.6A CA7-9 65 47 65 65 47 47 65 47<br />
7 CK7/CKU7 KTA7-25S-2.5A CA7-9 65 30 65 65 30 10 65 ~<br />
8 CK7/CKU7 KTA7-25S-4.0A CA7-9 65 30 65 ~ 30 ~ ~ ~<br />
9 CK7/CKU7 KTA7-25S-6.3A CA7-9 65 30 65 ~ ~ ~ ~ ~<br />
10 CK7/CKU7 KTA7-25S-10A CA7-12 65 30 65 ~ ~ ~ ~ ~<br />
11 CK7/CKU7 KTA7-25S-16A CA7-16 30 30 30 ~ ~ ~ ~ ~<br />
12 CK7/CKU7 KTA7-25H-4.0A CA7-23 65 30 65 ~ 30 ~ 65 30<br />
13 CK7/CKU7 KTA7-25H-16A CA7-23 30 30 65 ~ ~ ~ ~ ~<br />
14 CK7/CKU7 KTA7-25S-20A CA7-23 30 30 10 ~ ~ ~ ~ ~<br />
15 CK7/CKU7 KTA7-25S-25A CA7-23 30 30 ~ ~ ~ ~ ~ ~<br />
16 CK7/CKU7 KTA7-25H-2.5A CA7-9 65 30 65 65 30 ~ 65 ~<br />
17 CK7/CKU7 KTA7-25H-2.5A CA7-23 65 30 65 65 30 30 65 30<br />
18 CK7/CKU7 KTA7-25H-4.0A CA7-9 65 30 65 65 30 ~ ~ ~<br />
19 CK7/CKU7 KTA7-25H-4.0A CA7-23 65 30 65 65 30 30 65 30<br />
20 CK7/CKU7 KTA7-25H-6.3A CA7-9 65 30 65 65 30 ~ ~ ~<br />
21 CK7 KTA7-25H-6.3A CA7-30 65 30 65 65 30 30 65 30<br />
22 CK7/CKU7 KTA7-25H-10A CA7-12 65 30 65 65 30 ~ ~ ~<br />
23 CK7 KTA7-25H-10A CA7-30 65 30 65 65 30 30 65 30<br />
24 CK7/CKU7 KTA7-25H-16A CA7-16 65 30 65 65 30 ~ ~ ~<br />
25 CK7 KTA7-25H-16A CA7-30 65 30 65 65 30 30 65 30<br />
26 CK7/CKU7 KTA7-25H-20A CA7-23 65 30 65 65 ~ ~ ~ ~<br />
27 CK7 KTA7-25H-20A CA7-30 65 30 65 65 ~ ~ 65 ~<br />
28 CK7/CKU7 KTA7-25H-25A CA7-23 30 30 65 65 ~ ~ ~ ~<br />
29 CK7 KTA7-25H-25A CA7-30 65 30 65 65 30 30 65 30<br />
30 CK7 KTA7-45H-10A CA7-30 65 30 65 65 30 30 65 30<br />
31 CK7 KTA7-45H-16A CA7-30 65 30 65 65 30 30 65 30<br />
32 CK7 KTA7-45H-20A CA7-30 65 30 65 65 30 30 65 30<br />
33 CK7 KTA7-45H-25A CA7-30 65 30 65 65 30 30 65 30<br />
34 CK7 KTA7-45H-32A CA7-30 65 30 65 65 30 30 65 30<br />
35 CK7 KTA7-45H-45A CA7-37 65 18 65 65 ~ ~ 65 ~<br />
36 CK7 KTA7-45H-45A CA7-45 65 18 65 65 ~ ~ 65 ~<br />
480Y /<br />
277V<br />
600Y /<br />
347V<br />
F<br />
<strong>Motor</strong> <strong>Circuit</strong><br />
<strong>Controllers</strong><br />
Ecom<br />
Discount Schedule A-1<br />
F55
Wiring Diagrams<br />
Series CK7<br />
F<br />
<strong>Motor</strong> <strong>Circuit</strong><br />
<strong>Controllers</strong><br />
EcomboPlus Combination <strong>Starters</strong><br />
CK7-9...23<br />
CK7-30...43<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />
Ecom<br />
F56<br />
Discount Schedule A-1
Dimensions<br />
Series CL(U)4 and CL(U)7<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />
Ecombo Combination <strong>Starters</strong><br />
CL4 and CLU4 Ecombo <strong>Starters</strong> with <strong>KT7</strong>-25S<br />
• Dimensions are shown in millimeters (inches).<br />
• Dimensions are not intended to be used for manufacturing purposes.<br />
CL7-9…23 and CLU7-9…23 Ecombo <strong>Starters</strong> with <strong>KT7</strong>-25S<br />
• Dimensions are shown in millimeters (inches).<br />
• Dimensions are not intended to be used for manufacturing purposes.<br />
Catalog Number a a1 b b1 b2 c c1<br />
CL7-9...CL7-23 45 (1-25/32) 0 178 (7) 45 (1-25/32) ~ 83.5 (3-19/64) 70 (2-49/64)<br />
CL7-9...CL7-23 with -TE Terminal Adaptor 45 (1-25/32) 0 188 (7-13/32) 55 (2-5/32) ~ 83.5 (3-19/64) 70 (2-49/64)<br />
CLU7-9...CLU7-23 45 (1-25/32) 10 (25/64) 178 (7) 45 (1-25/32) ~ 83.5 (3-19/64) 70 (2-49/64)<br />
CLU7-9...CLU7-23 with -TE Terminal Adaptor 45 (1-25/32) 10 (25/64) 188 (7-13/32) 55 (2-5/32) ~ 83.5 (3-19/64) 70 (2-49/64)<br />
F<br />
<strong>Motor</strong> <strong>Circuit</strong><br />
<strong>Controllers</strong><br />
Ecom<br />
Discount Schedule A-1<br />
F57
Dimensions<br />
CK(U)7-9…23<br />
F<br />
<strong>Motor</strong> <strong>Circuit</strong><br />
<strong>Controllers</strong><br />
EcomboPlus Combination <strong>Starters</strong><br />
CK7-9…23 and CKU7-9…23 EcomboPlus <strong>Starters</strong><br />
• Dimensions are shown in millimeters (inches).<br />
• Dimensions are not intended to be used for manufacturing purposes.<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />
Ecom<br />
F58<br />
Discount Schedule A-1
Mounting Position and Dimensions<br />
CK7-9…23<br />
EcomboPlus Combination <strong>Starters</strong><br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />
• Dimensions are shown in millimeters.<br />
• Dimensions are not intended to be used for manufacturing purposes.<br />
with "TE" Terminal Adaptor<br />
CK7-9…23<br />
F<br />
<strong>Motor</strong> <strong>Circuit</strong><br />
<strong>Controllers</strong><br />
Ecom<br />
Discount Schedule A-1<br />
F59
Dimensions<br />
CK7-30 and CK7-37<br />
F<br />
<strong>Motor</strong> <strong>Circuit</strong><br />
<strong>Controllers</strong><br />
EcomboPlus Combination <strong>Starters</strong><br />
CK7-30 and CK7-37<br />
• Dimensions are shown in millimeters.<br />
• Dimensions are not intended to be used for manufacturing purposes.<br />
A (mm) B (mm)<br />
CK7-30<br />
135 124<br />
CK7-37<br />
<strong>KT7</strong>-45H<br />
CK7-30C<br />
179 168<br />
CK7-37C<br />
C (mm)<br />
CA7-PV 154.5<br />
CZE7 173.5<br />
CV7 176.5<br />
CA7-PV 198.5<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />
Ecom<br />
F60<br />
Discount Schedule A-1
Dimensions<br />
CK7-43<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />
EcomboPlus Combination <strong>Starters</strong><br />
CK7-43<br />
• Dimensions are shown in millimeters.<br />
• Dimensions are not intended to be used for manufacturing purposes.<br />
A (mm) B (mm)<br />
CK7-43<br />
135 118.5<br />
<strong>KT7</strong>-45H<br />
CK7-43C 179 162.5<br />
C (mm)<br />
CA7-PV 157<br />
CZE7 176<br />
CV7 179<br />
CA7-PV 201<br />
F<br />
<strong>Motor</strong> <strong>Circuit</strong><br />
<strong>Controllers</strong><br />
Ecom<br />
Discount Schedule A-1<br />
F61
Mounting Position and Dimensions<br />
CK7-43<br />
EcomboPlus Combination <strong>Starters</strong><br />
F<br />
<strong>Motor</strong> <strong>Circuit</strong><br />
<strong>Controllers</strong> controller<br />
• Dimensions are shown in millimeters.<br />
• Dimensions are not intended to be used for manufacturing purposes.<br />
CK7-43<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />
Ecom<br />
F62<br />
Discount Schedule A-1
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />
Enclosed KTA7 <strong>Controllers</strong><br />
Enclosed CX7 <strong>Starters</strong><br />
F<br />
<strong>Circuit</strong><br />
F<strong>Motor</strong> <strong>Controllers</strong> controller<br />
Encl.<br />
F63
Type E Self-Protected <strong>Manual</strong> <strong>Motor</strong> Controller<br />
Enclosed Series KTA7<br />
F<br />
<strong>Motor</strong> <strong>Circuit</strong><br />
<strong>Controllers</strong><br />
Encl.<br />
Enclosed KTA7 - IP65<br />
Max. Horsepower ➊➋➌<br />
Three Phase<br />
200V 230V 460V 575V<br />
Amp / Horsepower<br />
Rating<br />
O/L Relay<br />
Ampere<br />
Range<br />
Magnetic<br />
Response<br />
Current<br />
➊ Horsepower ratings shown in the table above are for reference. The final<br />
selection of the manual starter depends on the actual motor full load current<br />
and service factor.<br />
• For motor with service factor less than 1.15. Use motor nameplate full load<br />
current times 0.9 and choose the motor starter with the appropriate current<br />
range. Example: <strong>Motor</strong> FLC = 4.2A; S.F. = 1.0. 4.2A x 0.9 = 3.78A. Select<br />
catalog number KTA7-25S-4.0A.<br />
Non-metallic (IP65) Enclosure<br />
Catalog Number ➍<br />
Price<br />
KTA7-25S Standard Interrupting Capacity<br />
~ ~ ~ ~ 0.10…0.16 2.1 KTA7-25S-0.16A-CG 238 AY<br />
~ ~ ~ ~ 0.16…0.25 3.3 KTA7-25S-0.25A-CG 238 AY<br />
~ ~ ~ ~ 0.25…0.40 5.2 KTA7-25S-0.4A-CG 238 AY<br />
~ ~ ~ ~ 0.40…0.63 8.2 KTA7-25S-0.63A-CG 259 AY<br />
~ ~ 1/2 3/4 0.63…1.0 13 KTA7-25S-1A-CG 259 AY<br />
~ ~ 1 1 1.0…1.6 21 KTA7-25S-1.6A-CG 259 AY<br />
1/2 3/4 1-1/2 2 1.6…2.5 33 KTA7-25S-2.5A-CG 259 AY<br />
1 1 3 3 2.5…4 52 KTA7-25S-4A-CG 259 AY<br />
1-1/2 2 5 ~ 4…6.3 82 KTA7-25S-6.3A-CG 259 AY<br />
3 3 7-1/2 ~ 6.3…10 130 KTA7-25S-10A-CG 259 AY<br />
3 5 10 ~ 10…16 208 KTA7-25S-16A-CG 281 AY<br />
5 7-1/2 15 ~ 14.5…20 260 KTA7-25S-20A-CG 281 AY<br />
7-1/2 7-1/2 15 20 18…25 325 KTA7-25S-25A-CG ➏ 281 AY<br />
Modifications (Factory Assembled)<br />
Description<br />
<strong>KT7</strong> Auxiliaries & Trip Contacts - Front Mount<br />
1 NO Auxiliary<br />
1 NC Auxiliary<br />
1 NO + 1 NC Auxiliary<br />
2 NO Auxiliaries<br />
1 NO Trip + 1 NC Auxiliary<br />
1 NO Trip + 1 NO Auxiliary<br />
<strong>KT7</strong> Auxiliaries - Side Mount<br />
2 NC Auxiliaries<br />
2 NO Auxiliaries<br />
1 NO + 1 NC Auxiliary<br />
Additional <strong>KT7</strong> Trip Contacts - Side Mount<br />
1 NO Thermal-Mag + 1 NO Mag Only<br />
1 NO Thermal-Mag + 1 NC Mag Only<br />
1 NC Thermal-Mag + 1 NO Mag Only<br />
Accessories<br />
Undervoltage Release Module<br />
Shunt Release Module<br />
Select coil voltage<br />
from table at right<br />
Add Suffix to<br />
Catalog Number<br />
-A10<br />
-A01<br />
-A11<br />
-A20<br />
-T10A01<br />
-T10A10<br />
-AS02<br />
-AS20<br />
-AS11<br />
-R00<br />
-R01<br />
-R10<br />
-UA-✱<br />
-<strong>AA</strong>-✱<br />
Price<br />
Adder<br />
33<br />
33<br />
37<br />
37<br />
47<br />
47<br />
47<br />
47<br />
47<br />
56<br />
56<br />
56<br />
75<br />
75<br />
Dimension<br />
Code<br />
Coil Selection (✱)<br />
Coil Voltage Range<br />
Code 50 Hz 60 Hz<br />
24V 21V 24V<br />
28V 24V 28V<br />
120V 105V 120V<br />
127V 110V 127V<br />
230V 220...230V ~<br />
240V ~ 240...260V<br />
277V 240V 277V<br />
460V 380...400V 400...460V<br />
480V 415V 480V<br />
Includes:<br />
• Non-metallic (IP65) enclosure with integrated<br />
IP65 operator – watertight, dusttight<br />
• <strong>KT7</strong>-25S (Standard Interrupting Capacity)<br />
“Type E” Self-protected <strong>Manual</strong> Controller<br />
• Terminal Adaptor for Type E Applications<br />
(Cat.# <strong>KT7</strong>-25-TE)<br />
• Gray and black IP65 handle ➍➎<br />
Enclosure Only<br />
Description<br />
Catalog<br />
Number Price<br />
Gray/Black handle <strong>KT7</strong>-AYTG2 90<br />
Red/Yellow handle <strong>KT7</strong>-AYTJ2 90<br />
➋ Magnetic trip is fixed at 13x the maximum value of the current adjustment range.<br />
➌ KTA7 may be applied to single phase loads if 3 poles of device are wired in series.<br />
See footnote ➊ for device selection criteria.<br />
➍ A red and yellow handle may be selected instead of the standard gray and black<br />
handle. Change “CG” suffix to “CJ”. Ex: Change KTA7-25S-0.16-CG to<br />
KTA7-25S-0.16-CJ.<br />
➎ Handles are built-in to the enclosure and are not available as components.<br />
➏ KTA7-25S-25A is suitable for use as a manual motor starter only because the<br />
KTA7-25S-25A is not type E rated. Additional units on this page may be applicable<br />
as a manual motor starter only (i.e. @ 575V).<br />
➐ See F76 for dimensional information.<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />
F64<br />
Discount Schedule A-1
Type E Self Protected <strong>Manual</strong> <strong>Motor</strong> Controller<br />
Enclosed Series KTA7<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />
Enclosed KTA7 - Type 4 / 4X / 12<br />
Max. Horsepower ➊➋➌<br />
Three Phase<br />
200V 230V 460V 575V<br />
Amp / Horsepower<br />
Rating<br />
O/L Relay<br />
Ampere<br />
Range<br />
Magnetic<br />
Response<br />
Current<br />
➊ Horsepower ratings shown in the table above are for reference. The final<br />
selection of the manual starter depends on the actual motor full load current<br />
and service factor.<br />
• For motor with service factor less than 1.15. Use motor nameplate full load<br />
current times 0.9 and choose the motor starter with the appropriate current<br />
range. Example: <strong>Motor</strong> FLC = 4.2A; S.F. = 1.0. 4.2A x 0.9 = 3.78A. Select<br />
catalog number KTA7-25S-4.0A.<br />
➋ Magnetic trip is fixed at 13x the maximum value of the current adjustment range.<br />
➌ KTA7 may be applied to single phase loads if 3 poles of device are wired in series.<br />
See footnote ➊ for device selection criteria.<br />
➍ A red and yellow handle may be selected instead of the standard gray and black<br />
handle. Change “WG” suffix to “WJ”. Ex: Change KTA7-25S-0.16-VG to<br />
KTA7-25S-0.16-VJ.<br />
➎ KTA7-25S-25A is suitable for use as a manual motor starter only because the<br />
KTA7-25S-25A is not type E rated. Additional units on this page may be applicable<br />
as a manual motor starter only (i.e. @ 575V).<br />
➐ See F76 for dimensional information.<br />
Non-metallic, Type 4 / 4X / 12 Enclosure<br />
Catalog Number ➍<br />
Price<br />
KTA7-25S Standard Interrupting Capacity<br />
~ ~ ~ ~ 0.10…0.16 2.1 KTA7-25S-0.16A-VG 350 Q5<br />
~ ~ ~ ~ 0.16…0.25 3.3 KTA7-25S-0.25A-VG 350 Q5<br />
~ ~ ~ ~ 0.25…0.40 5.2 KTA7-25S-0.4A-VG 350 Q5<br />
~ ~ ~ ~ 0.40…0.63 8.2 KTA7-25S-0.63A-VG 365 Q5<br />
~ ~ 1/2 3/4 0.63…1.0 13 KTA7-25S-1A-VG 365 Q5<br />
~ ~ 1 1 1.0…1.6 21 KTA7-25S-1.6A-VG 365 Q5<br />
1/2 3/4 1-1/2 2 1.6…2.5 33 KTA7-25S-2.5A-VG 365 Q5<br />
1 1 3 3 2.5…4 52 KTA7-25S-4A-VG 365 Q5<br />
1-1/2 2 5 ~ 4…6.3 82 KTA7-25S-6.3A-VG 365 Q5<br />
3 3 7-1/2 ~ 6.3…10 130 KTA7-25S-10A-VG 365 Q5<br />
3 5 10 ~ 10…16 208 KTA7-25S-16A-VG 392 Q5<br />
5 7-1/2 15 ~ 14.5…20 260 KTA7-25S-20A-VG 392 Q5<br />
7-1/2 7-1/2 15 20 18…25 325 KTA7-25S-25A-VG ➎ 392 Q5<br />
KTA7-25H Standard Interrupting Capacity<br />
1/2 3/4 1-1/2 2 1.6…2.5 33 KTA7-25H-2.5A-VG 408 Q6<br />
1 1 3 3 2.5…4 52 KTA7-25H-4A-VG 408 Q6<br />
1-1/2 2 5 5 4…6.3 82 KTA7-25H-6.3A-VG 408 Q6<br />
3 3 7-1/2 10 6.3…10 130 KTA7-25H-10A-VG 435 Q6<br />
3 5 10 15 10…16 208 KTA7-25H-16A-VG 435 Q6<br />
5 7-1/2 15 ~ 14.5…20 260 KTA7-25H-20A-VG 435 Q6<br />
7-1/2 7-1/2 15 ~ 18…25 325 KTA7-25H-25A-VG 435 Q6<br />
KTA7-45H Standard Interrupting Capacity<br />
3 3 7-1/2 10 6.3…10 130 KTA7-45H-10A-VG R/F Q7<br />
3 5 10 15 10…16 208 KTA7-45H-16A-VG R/F Q7<br />
5 7-1/2 15 20 14.5…20 260 KTA7-45H-20A-VG R/F Q7<br />
5 7-1/2 20 25 18…25 325 KTA7-45H-25A-VG R/F Q7<br />
10 10 25 30 23…32 416 KTA7-45H-32A-VG R/F Q7<br />
15 15 30 ~ 32…45 585 KTA7-45H-45A-VG R/F Q7<br />
Dimension<br />
Code<br />
Includes:<br />
• Type 4 / 4X / 12 enclosure – watertight, dusttight,<br />
corrosion resistant<br />
• KTA7 “Type E” Self-protected <strong>Manual</strong><br />
Controller (Standard Interrupting Capacity)<br />
• Terminal Adaptor for Type E Applications<br />
(Cat.# <strong>KT7</strong>-25[45]-TE)<br />
• Gray and black Type 4/4X/12; IP66 handle<br />
(Cat.# <strong>KT7</strong>-HTN) ➍<br />
Modifications (Factory Assembled)<br />
Description<br />
<strong>KT7</strong> Auxiliaries & Trip<br />
Contacts - Front Mount<br />
1 NO Auxiliary<br />
1 NC Auxiliary<br />
1 NO + 1 NC Auxiliary<br />
2 NO Auxiliaries<br />
1 NO Trip + 1 NC Auxiliary<br />
1 NO Trip + 1 NO Auxiliary<br />
<strong>KT7</strong> Auxiliaries - Side Mount<br />
2 NC Auxiliaries<br />
2 NO Auxiliaries<br />
1 NO + 1 NC Auxiliary<br />
Additional <strong>KT7</strong> Trip Contacts,<br />
Side Mount<br />
1 NO Thermal-Mag+1 NO<br />
Mag<br />
1 NO Thermal-Mag+1 NC<br />
Mag<br />
1 NC Thermal-Mag+1 NO<br />
Mag<br />
Accessories<br />
Undervoltage Release Module<br />
Shunt Release Module<br />
Select coil voltage from table below<br />
Coil Selection (✱)<br />
Coil Voltage Range<br />
Code 50 Hz 60 Hz<br />
24V 21V 24V<br />
28V 24V 28V<br />
120V 105V 120V<br />
127V 110V 127V<br />
230V 220...230V ~<br />
240V ~ 240...260V<br />
277V 240V 277V<br />
460V 380...400V 400...460V<br />
480V 415V 480V<br />
Add Suffix<br />
to Cat.<br />
Number<br />
-A10<br />
-A01<br />
-A11<br />
-A20<br />
-T10A01<br />
-T10A10<br />
-AS02<br />
-AS20<br />
-AS11<br />
-R00<br />
-R01<br />
-R10<br />
-UA-✱<br />
-<strong>AA</strong>-✱<br />
Price<br />
Adder<br />
33<br />
33<br />
37<br />
37<br />
47<br />
47<br />
47<br />
47<br />
47<br />
56<br />
56<br />
56<br />
75<br />
75<br />
F<br />
<strong>Motor</strong> <strong>Circuit</strong><br />
<strong>Controllers</strong><br />
Encl.<br />
Discount Schedule A-1<br />
F65
Type E Self-Protected <strong>Manual</strong> <strong>Motor</strong> Controller<br />
Enclosed Series KTA7<br />
F<br />
<strong>Motor</strong> <strong>Circuit</strong><br />
<strong>Controllers</strong><br />
Encl.<br />
Enclosed KTA7 - Type 12<br />
Max. Horsepower ➊➋➌<br />
Three Phase<br />
200V 230V 460V 575V<br />
Amp / Horsepower<br />
Rating<br />
O/L Relay<br />
Ampere<br />
Range<br />
Magnetic<br />
Response<br />
Current<br />
Painted Steel, Type 12 Enclosure<br />
Catalog Number ➍<br />
Price<br />
KTA7-25S Standard Interrupting Capacity<br />
~ ~ ~ ~ 0.10…0.16 2.1 KTA7-25S-0.16A-DG 375 L<br />
~ ~ ~ ~ 0.16…0.25 3.3 KTA7-25S-0.25A-DG 375 L<br />
~ ~ ~ ~ 0.25…0.40 5.2 KTA7-25S-0.4A-DG 375 L<br />
~ ~ ~ ~ 0.40…0.63 8.2 KTA7-25S-0.63A-DG 395 L<br />
~ ~ 1/2 3/4 0.63…1.0 13 KTA7-25S-1A-DG 395 L<br />
~ ~ 1 1 1.0…1.6 21 KTA7-25S-1.6A-DG 395 L<br />
1/2 3/4 1-1/2 2 1.6…2.5 33 KTA7-25S-2.5A-DG 395 L<br />
1 1 3 3 2.5…4 52 KTA7-25S-4A-DG 395 L<br />
1-1/2 2 5 ~ 4…6.3 82 KTA7-25S-6.3A-DG 395 L<br />
3 3 7-1/2 ~ 6.3…10 130 KTA7-25S-10A-DG 395 L<br />
3 5 10 ~ 10…16 208 KTA7-25S-16A-DG 395 L<br />
5 7-1/2 15 ~ 14.5…20 260 KTA7-25S-20A-DG 417 L<br />
7-1/2 7-1/2 15 20 18…25 325 KTA7-25S-25A-DG ➎ 417 L<br />
KTA7-25H Standard Interrupting Capacity<br />
1/2 3/4 1-1/2 2 1.6…2.5 33 KTA7-25H-2.5A-DG 433 L<br />
1 1 3 3 2.5…4 52 KTA7-25H-4A-DG 433 L<br />
1-1/2 2 5 5 4…6.3 82 KTA7-25H-6.3A-DG 433 L<br />
3 3 7-1/2 10 6.3…10 130 KTA7-25H-10A-DG 460 L<br />
3 5 10 15 10…16 208 KTA7-25H-16A-DG 460 L<br />
5 7-1/2 15 ~ 14.5…20 260 KTA7-25H-20A-DG 460 L<br />
7-1/2 7-1/2 15 ~ 18…25 325 KTA7-25H-25A-DG 460 L<br />
➊ Horsepower ratings shown in the table above are for reference. The final<br />
selection of the manual starter depends on the actual motor full load current<br />
and service factor.<br />
• For motor with service factor less than 1.15. Use motor nameplate full load<br />
current times 0.9 and choose the motor starter with the appropriate current<br />
range. Example: <strong>Motor</strong> FLC = 4.2A; S.F. = 1.0. 4.2A x 0.9 = 3.78A. Select<br />
catalog number KTA7-25S-4.0A.<br />
➋ Magnetic trip is fixed at 13x the maximum value of the current adjustment range.<br />
➌ KTA7 may be applied to single phase loads if 3 poles of device are wired in series.<br />
See footnote ➊ for device selection criteria.<br />
➍ A red and yellow handle may be selected instead of the standard gray and black<br />
handle. Change “DG” suffix to “DJ”. Ex: Change KTA7-25S-0.16-DG to<br />
KTA7-25S-0.16-DJ.<br />
➎ KTA7-25S-25A is suitable for use as a manual motor starter only because the<br />
KTA7-25S-25A is not type E rated. Additional units on this page may be applicable<br />
as a manual motor starter only (i.e. @ 575V).<br />
➏ See F76 for dimensional information.<br />
Dimension<br />
Code<br />
Includes:<br />
• Type 12 enclosure – dusttight<br />
• KTA7 “Type E” Self-protected <strong>Manual</strong><br />
Controller (Standard Interrupting Capacity)<br />
• Terminal Adaptor for Type E Applications<br />
(Cat.# <strong>KT7</strong>-25-TE)<br />
• Gray and black Type 4/4X/12; IP66 handle<br />
(Cat.# <strong>KT7</strong>-HTN) ➍<br />
Modifications (Factory Assembled)<br />
Description<br />
<strong>KT7</strong> Auxiliaries & Trip<br />
Contacts - Front Mount<br />
1 NO Auxiliary<br />
1 NC Auxiliary<br />
1 NO + 1 NC Auxiliary<br />
2 NO Auxiliaries<br />
1 NO Trip + 1 NC Auxiliary<br />
1 NO Trip + 1 NO Auxiliary<br />
<strong>KT7</strong> Auxiliaries - Side Mount<br />
2 NC Auxiliaries<br />
2 NO Auxiliaries<br />
1 NO + 1 NC Auxiliary<br />
Additional <strong>KT7</strong> Trip Contacts,<br />
Side Mount<br />
1 NO Thermal-Mag+1 NO<br />
Mag<br />
1 NO Thermal-Mag+1 NC<br />
Mag<br />
1 NC Thermal-Mag+1 NO<br />
Mag<br />
Accessories<br />
Undervoltage Release Module<br />
Shunt Release Module<br />
Select coil voltage from table below<br />
Coil Selection (✱)<br />
Coil Voltage Range<br />
Code 50 Hz 60 Hz<br />
24V 21V 24V<br />
28V 24V 28V<br />
120V 105V 120V<br />
127V 110V 127V<br />
230V 220...230V ~<br />
240V ~ 240...260V<br />
277V 240V 277V<br />
460V 380...400V 400...460V<br />
480V 415V 480V<br />
Add Suffix<br />
to Cat.<br />
Number<br />
-A10<br />
-A01<br />
-A11<br />
-A20<br />
-T10A01<br />
-T10A10<br />
-AS02<br />
-AS20<br />
-AS11<br />
-R00<br />
-R01<br />
-R10<br />
-UA-✱<br />
-<strong>AA</strong>-✱<br />
Price<br />
Adder<br />
33<br />
33<br />
37<br />
37<br />
47<br />
47<br />
47<br />
47<br />
47<br />
56<br />
56<br />
56<br />
75<br />
75<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />
F66<br />
Discount Schedule A-1
Type E Self-Protected <strong>Manual</strong> <strong>Motor</strong> Controller<br />
Enclosed Series KTA7<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />
Enclosed KTA7 - Type 4 / 12<br />
Max. Horsepower ➊➋➌<br />
Three Phase<br />
200V 230V 460V 575V<br />
Amp / Horsepower<br />
Rating<br />
O/L Relay<br />
Ampere<br />
Range<br />
Magnetic<br />
Response<br />
Current<br />
➊ Horsepower ratings shown in the table above are for reference. The final<br />
selection of the manual starter depends on the actual motor full load current<br />
and service factor.<br />
• For motor with service factor less than 1.15. Use motor nameplate full load<br />
current times 0.9 and choose the motor starter with the appropriate current<br />
range. Example: <strong>Motor</strong> FLC = 4.2A; S.F. = 1.0. 4.2A x 0.9 = 3.78A. Select<br />
catalog number KTA7-25S-4.0A.<br />
➋ Magnetic trip is fixed at 13x the maximum value of the current adjustment range.<br />
➌ KTA7 may be applied to single phase loads if 3 poles of device are wired in series.<br />
See footnote ➊ for device selection criteria.<br />
➍ A red and yellow handle may be selected instead of the standard gray and black<br />
handle. Change “WG” suffix to “WJ”. Ex: Change KTA7-25S-0.16-WG to<br />
KTA7-25S-0.16-WJ.<br />
➎ KTA7-25S-25A is suitable for use as a manual motor starter only because the<br />
KTA7-25S-25A is not type E rated. Additional units on this page may be applicable<br />
as a manual motor starter only (i.e. @ 575V).<br />
➏ See F76 for dimensional information.<br />
Painted Steel, Type 4 / 12 Enclosure<br />
Catalog Number ➍<br />
KTA7-25S Standard Interrupting Capacity<br />
~ ~ ~ ~ 0.10…0.16 2.1 KTA7-25S-0.16A-WG 417 W6<br />
~ ~ ~ ~ 0.16…0.25 3.3 KTA7-25S-0.25A-WG 417 W6<br />
~ ~ ~ ~ 0.25…0.40 5.2 KTA7-25S-0.4A-WG 417 W6<br />
~ ~ ~ ~ 0.40…0.63 8.2 KTA7-25S-0.63A-WG 437 W6<br />
~ ~ 1/2 3/4 0.63…1.0 13 KTA7-25S-1A-WG 437 W6<br />
~ ~ 1 1 1.0…1.6 21 KTA7-25S-1.6A-WG 437 W6<br />
1/2 3/4 1-1/2 2 1.6…2.5 33 KTA7-25S-2.5A-WG 437 W6<br />
1 1 3 3 2.5…4 52 KTA7-25S-4A-WG 437 W6<br />
1-1/2 2 5 ~ 4…6.3 82 KTA7-25S-6.3A-WG 437 W6<br />
3 3 7-1/2 ~ 6.3…10 130 KTA7-25S-10A-WG 437 W6<br />
3 5 10 ~ 10…16 208 KTA7-25S-16A-WG 459 W6<br />
5 7-1/2 15 ~ 14.5…20 260 KTA7-25S-20A-WG 459 W6<br />
7-1/2 7-1/2 15 20 18…25 325 KTA7-25S-25A-WG ➎ 459 W6<br />
KTA7-25H Standard Interrupting Capacity<br />
1/2 3/4 1-1/2 2 1.6…2.5 33 KTA7-25H-2.5A-WG 475 W6<br />
1 1 3 3 2.5…4 52 KTA7-25H-4A-WG 475 W6<br />
1-1/2 2 5 5 4…6.3 82 KTA7-25H-6.3A-WG 475 W6<br />
3 3 7-1/2 10 6.3…10 130 KTA7-25H-10A-WG 502 W6<br />
3 5 10 15 10…16 208 KTA7-25H-16A-WG 502 W6<br />
5 7-1/2 15 ~ 14.5…20 260 KTA7-25H-20A-WG 502 W6<br />
7-1/2 7-1/2 15 ~ 18…25 325 KTA7-25H-25A-WG 502 W6<br />
KTA7-45H Standard Interrupting Capacity<br />
3 3 7-1/2 10 6.3…10 130 KTA7-45H-10A-WG 671 R/F<br />
3 5 10 15 10…16 208 KTA7-45H-16A-WG 671 R/F<br />
5 7-1/2 15 20 14.5…20 260 KTA7-45H-20A-WG 671 R/F<br />
5 7-1/2 20 25 18…25 325 KTA7-45H-25A-WG 671 R/F<br />
10 10 25 30 23…32 416 KTA7-45H-32A-WG 709 R/F<br />
15 15 30 ~ 32…45 585 KTA7-45H-45A-WG 709 R/F<br />
Price<br />
Dimension<br />
Code<br />
Includes:<br />
• Type 4 / 12 enclosure – watertight, dusttight<br />
• KTA7 “Type E” Self-protected <strong>Manual</strong><br />
Controller (Standard Interrupting Capacity)<br />
• Terminal Adaptor for Type E Applications<br />
(Cat.# <strong>KT7</strong>-25[45]-TE)<br />
• Gray and black Type 4/4X/12; IP66 handle<br />
(Cat.# <strong>KT7</strong>-HTN) ➍<br />
Modifications (Factory Assembled)<br />
Description<br />
<strong>KT7</strong> Auxiliaries & Trip<br />
Contacts - Front Mount<br />
1 NO Auxiliary<br />
1 NC Auxiliary<br />
1 NO + 1 NC Auxiliary<br />
2 NO Auxiliaries<br />
1 NO Trip + 1 NC Auxiliary<br />
1 NO Trip + 1 NO Auxiliary<br />
<strong>KT7</strong> Auxiliaries - Side Mount<br />
2 NC Auxiliaries<br />
2 NO Auxiliaries<br />
1 NO + 1 NC Auxiliary<br />
Additional <strong>KT7</strong> Trip Contacts,<br />
Side Mount<br />
1 NO Thermal-Mag+1 NO<br />
Mag<br />
1 NO Thermal-Mag+1 NC<br />
Mag<br />
1 NC Thermal-Mag+1 NO<br />
Mag<br />
Accessories<br />
Undervoltage Release Module<br />
Shunt Release Module<br />
Select coil voltage from table below<br />
Coil Selection (✱)<br />
Coil Voltage Range<br />
Code 50 Hz 60 Hz<br />
24V 21V 24V<br />
28V 24V 28V<br />
120V 105V 120V<br />
127V 110V 127V<br />
230V 220...230V ~<br />
240V ~ 240...260V<br />
277V 240V 277V<br />
460V 380...400V 400...460V<br />
480V 415V 480V<br />
Add Suffix<br />
to Cat.<br />
Number<br />
-A10<br />
-A01<br />
-A11<br />
-A20<br />
-T10A01<br />
-T10A10<br />
-AS02<br />
-AS20<br />
-AS11<br />
-R00<br />
-R01<br />
-R10<br />
-UA-✱<br />
-<strong>AA</strong>-✱<br />
Price<br />
Adder<br />
33<br />
33<br />
37<br />
37<br />
47<br />
47<br />
47<br />
47<br />
47<br />
56<br />
56<br />
56<br />
75<br />
75<br />
F<br />
<strong>Motor</strong> <strong>Circuit</strong><br />
<strong>Controllers</strong><br />
Encl.<br />
Discount Schedule A-1<br />
F67
Non-Reversing Combination Controller, AC<br />
Enclosed Series CX7<br />
F<br />
<strong>Motor</strong> <strong>Circuit</strong><br />
<strong>Controllers</strong><br />
Encl.<br />
Enclosed Non-Reversing Combination Controller, AC Operation - Type 4 / 12<br />
Max. Horsepower ➊➋➌<br />
Three Phase<br />
200V 230V 460V 575V<br />
Amp / Horsepower<br />
Rating<br />
O/L Relay<br />
Ampere<br />
Range<br />
Magnetic<br />
Response<br />
Current<br />
Painted Steel, Type 4 / 12 Enclosure<br />
Catalog Number ➍<br />
KTA7-25S Standard Interrupting Capacity<br />
~ ~ ~ ~ 0.10…0.16 2.1 CX7-9-10-✱-AS0.16A-A10-WG 548 W6<br />
~ ~ ~ ~ 0.16…0.25 3.3 CX7-9-10-✱-AS0.25A-A10-WG 548 W6<br />
~ ~ ~ ~ 0.25…0.40 5.2 CX7-9-10-✱-AS0.4A-A10-WG 569 W6<br />
~ ~ ~ ~ 0.40…0.63 8.2 CX7-9-10-✱-AS0.63A-A10-WG 569 W6<br />
~ ~ 1/2 3/4 0.63…1.0 13 CX7-9-10-✱-AS1A-A10-WG 569 W6<br />
~ ~ 1 1 1.0…1.6 21 CX7-9-10-✱-AS1.6A-A10-WG 569 W6<br />
1/2 3/4 1-1/2 2 1.6…2.5 33 CX7-9-10-✱-AS2.5A-A10-WG 569 W6<br />
1 1 3 3 2.5…4 52 CX7-9-10-✱-AS4A-A10-WG 569 W6<br />
1-1/2 2 5 ~ 4…6.3 82 CX7-9-10-✱-AS6.3A-A10-WG 569 W6<br />
3 3 7-1/2 ~ 6.3…10 130 CX7-12-10-✱-AS10A-A10-WG 590 W6<br />
3 5 10 ~ 10…16 208 CX7-16-10-✱-AS16A-A10-WG 623 W6<br />
5 7-1/2 15 ~ 14.5…20 260 CX7-23-10-✱-AS20A-A10-WG 636 W6<br />
KTA7-25H Standard Interrupting Capacity<br />
1/2 3/4 1-1/2 2 1.6…2.5 33 CX7-9-10-✱-AH2.5A-A10-WG 606 W6<br />
1 1 3 3 2.5…4 52 CX7-9-10-✱-AH4A-A10-WG 606 W6<br />
1-1/2 2 5 5 4…6.3 82 CX7-9-10-✱-AH6.3A-A10-WG 606 W6<br />
3 3 7-1/2 10 6.3…10 130 CX7-12-10-✱-AH10A-A10-WG 654 W6<br />
3 5 10 15 10…16 208 CX7-16-10-✱-AH16A-A10-WG 666 W6<br />
5 7-1/2 15 ~ 14.5…20 260 CX7-23-10-✱-AH20A-A10-WG 679 W6<br />
5 7-1/2 15 ~ 18…25 325 CX7-23-10-✱-AH25A-A10-WG 679 W6<br />
KTA7-45H Standard Interrupting Capacity<br />
3 3 7-1/2 10 6.3…10 130 CX7-30-10-✱-AH10A-A10-WG 831 W7<br />
3 5 10 15 10…16 208 CX7-30-10-✱-AH16A-A10-WG 831 W7<br />
5 7-1/2 15 15 14.5…20 260 CX7-30-10-✱-AH20A-A10-WG 831 W7<br />
5 7-1/2 15 15 18…25 325 CX7-30-10-✱-AH25A-A10-WG 831 W7<br />
7-1/2 10 20 25 23…32 416 CX7-30-10-✱-AH32A-A10-WG 850 W7<br />
10 10 25 30 32…45 585 CX7-37-10-✱-AH45A-A10-WG 894 W7<br />
10 15 30 ~ 32…45 585 CX7-43-10-✱-AH45A-A10-WG 908 W7<br />
Ordering Instructions<br />
Specify Catalog Number<br />
Replace (✱) with Coil Code<br />
Select modifications if required<br />
See Coil Code tables on<br />
this page for codes<br />
Price<br />
Dimension<br />
Code<br />
Includes:<br />
• Type 12 / 4 enclosure - watertight, dustight<br />
• KTA7 “Type E” Self-protected <strong>Motor</strong><br />
Controller with 1 NO front mount Auxiliary<br />
Contact (Cat #: <strong>KT7</strong>-PE1-10)<br />
• Terminal Adaptor for Type E Applications<br />
(Cat.# <strong>KT7</strong>-25[45]-TE)<br />
• CA7 contactor (for remote operation), AC coil<br />
• Power wiring<br />
• Gray and black Type 4/4X/12; IP66 handle<br />
(Cat.# <strong>KT7</strong>-HTN) ➍<br />
• Pilot device shown is factory installed option<br />
See page 72 for factory installed modifications<br />
Coil Codes (✱) ➎<br />
A.C.<br />
Coil Code<br />
Voltage Range<br />
50 Hz 60 Hz<br />
24Z 24V 24V<br />
120 110V 120V<br />
208 ~ 208V<br />
220W ~ 208V-240V<br />
240 220V 240V<br />
277 240V 277V<br />
380 380...400V 440V<br />
480 440V 480V<br />
600 550V 600V<br />
➊ Horsepower ratings shown in the table above are<br />
for reference. The final selection of the manual<br />
starter depends on the actual motor full load current<br />
and service factor.<br />
• For motor with service factor less than 1.15. Use<br />
motor nameplate full load current times 0.9 and<br />
choose the motor starter with the appropriate<br />
current range. Example: <strong>Motor</strong> FLC = 4.2A; S.F. =<br />
1.0. 4.2A x 0.9 = 3.78A. Select catalog number<br />
KTA7-25S-4.0A.<br />
➋ Magnetic trip is fixed at 13x the maximum value of the current adjustment range.<br />
➌ CX7 may be applied to single phase loads. See footnote 1 for device selection criteria.<br />
To order single phase unit, change “CX7” in catalog number to “CBX7”. Three<br />
pole series connection will be provided. Ex: Change CX7-9-10-✱-0.16A-A10-WG<br />
to CBX7-9-10-✱-0.16A-A10-WJ.<br />
➍ A red and yellow handle may be selected instead of the standard gray and black<br />
handle. Change “WG” suffix to “WJ”. Ex: Change CX7-9-10-✱-0.16A-A10-WG to<br />
CX7-9-10-✱-0.16A-A10-WJ.<br />
➎ Other voltages available, see Section A in this catalog. Non-standard coil voltages<br />
not listed here must be ordered and installed separately as renewal parts.<br />
➏ See F76 for dimensional information.<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />
F68<br />
Discount Schedule A-1
Reversing Combination Controller, AC<br />
Enclosed Series CXU7<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />
Enclosed Reversing Combination Controller, AC Operation - Type 4 / 12<br />
Max. Horsepower ➊➋➌<br />
Three Phase<br />
Amp / Horsepower<br />
Rating<br />
200V 230V 460V 575V<br />
O/L Relay<br />
Ampere<br />
Range<br />
Magnetic<br />
Response<br />
Current<br />
Painted Steel, Type 4 / 12 Enclosure<br />
Catalog Number ➍<br />
KTA7-25S Standard Interrupting Capacity<br />
~ ~ ~ ~ 0.10…0.16 2.1 CXU7-9-22-✱-AS0.16A-A10-WG 600 W6<br />
~ ~ ~ ~ 0.16…0.25 3.3 CXU7-9-22-✱-AS0.25A-A10-WG 600 W6<br />
~ ~ ~ ~ 0.25…0.40 5.2 CXU7-9-22-✱-AS0.4A-A10-WG 600 W6<br />
~ ~ ~ ~ 0.40…0.63 8.2 CXU7-9-22-✱-AS0.63A-A10-WG 620 W6<br />
~ ~ 1/2 3/4 0.63…1.0 13 CXU7-9-22-✱-AS1A-A10-WG 620 W6<br />
~ ~ 1 1 1.0…1.6 21 CXU7-9-22-✱-AS1.6A-A10-WG 620 W6<br />
1/2 3/4 1-1/2 2 1.6…2.5 33 CXU7-9-22-✱-AS2.5A-A10-WG 620 W6<br />
1 1 3 3 2.5…4 52 CXU7-9-22-✱-AS4A-A10-WG 620 W6<br />
1-1/2 2 5 ~ 4…6.3 82 CXU7-9-22-✱-AS6.3A-A10-WG 620 W6<br />
3 3 7-1/2 ~ 6.3…10 130 CXU7-12-22-✱-AS10A-A10-WG 646 W6<br />
3 5 10 ~ 10…16 208 CXU7-16-22-✱-AS16A-A10-WG 683 W6<br />
5 7-1/2 15 ~ 14.5…20 260 CXU7-23-22-✱-AS20A-A10-WG 698 W6<br />
KTA7-25H Standard Interrupting Capacity<br />
1/2 3/4 1-1/2 2 1.6…2.5 33 CXU7-9-22-✱-AH2.5A-A10-WG 657 W6<br />
1 1 3 3 2.5…4 52 CXU7-9-22-✱-AH4A-A10-WG 657 W6<br />
1-1/2 2 5 5 4…6.3 82 CXU7-9-22-✱-AH6.3A-A10-WG 657 W6<br />
3 3 7-1/2 10 6.3…10 130 CXU7-12-22-✱-AH10A-A10-WG 711 W6<br />
3 5 10 15 10…16 208 CXU7-16-22-✱-AH16A-A10-WG 726 W6<br />
5 7-1/2 15 ~ 14.5…20 260 CXU7-23-22-✱-AH20A-A10-WG 741 W6<br />
7-1/2 7-1/2 15 ~ 18…25 325 CXU7-23-22-✱-AH25A-A10-WG 741 W6<br />
KTA7-45H Standard Interrupting Capacity<br />
3 3 7-1/2 10 6.3…10 130 CXU7-30-22-✱-AH10A-A10-WG 869 W7<br />
3 5 10 15 10…16 208 CXU7-30-22-✱-AH16A-A10-WG 869 W7<br />
5 7-1/2 15 20 14.5…20 260 CXU7-30-22-✱-AH20A-A10-WG 869 W7<br />
5 7-1/2 20 25 18…25 325 CXU7-30-22-✱-AH25A-A10-WG 869 W7<br />
7-1/2 10 20 25 23…32 416 CXU7-30-22-✱-AH32A-A10-WG 900 W7<br />
10 10 25 30 32…45 585 CXU7-37-22-✱-AH45A-A10-WG 943 W7<br />
10 15 30 ~ 32…45 585 CXU7-43-22-✱-AH45A-A10-WG 979 W7<br />
Ordering Instructions<br />
Specify Catalog Number<br />
Replace (✱) with Coil Code<br />
Select modifications if required<br />
See Coil Code tables on<br />
this page for codes<br />
Price<br />
Dimension<br />
Code<br />
Includes:<br />
• Type 12 / 4 enclosure - watertight, dustight<br />
• <strong>KT7</strong> “Type E” <strong>Motor</strong> Controller with 1 NO<br />
front mount Auxiliary Contact<br />
(Cat #: <strong>KT7</strong>-PE1-10)<br />
• Terminal Adaptor for Type E Applications<br />
(Cat.# <strong>KT7</strong>-25[45]-TE)<br />
• CA7 contactors (for remote operation),<br />
AC coil<br />
• Power wiring<br />
• Gray and black Type 4/4X/12; IP66 handle<br />
(Cat.# <strong>KT7</strong>-HTN) ➍<br />
• Control power transformer, pilot device,<br />
terminals and other equipment shown are<br />
factory installed options<br />
See page 72 for factory installed modifications<br />
Coil Codes (✱) ➎<br />
A.C.<br />
Coil Code<br />
Voltage Range<br />
50 Hz 60 Hz<br />
24Z 24V 24V<br />
120 110V 120V<br />
208 ~ 208V<br />
220W ~ 208V-240V<br />
240 220V 240V<br />
277 240V 277V<br />
380 380...400V 440V<br />
480 440V 480V<br />
600 550V 600V<br />
➊ Horsepower ratings shown in the table above are<br />
for reference. The final selection of the manual<br />
starter depends on the actual motor full load current<br />
and service factor.<br />
• For motor with service factor less than 1.15. Use<br />
motor nameplate full load current times 0.9 and<br />
choose the motor starter with the appropriate<br />
current range. Example: <strong>Motor</strong> FLC = 4.2A; S.F. =<br />
1.0. 4.2A x 0.9 = 3.78A. Select catalog number<br />
KTA7-25S-4.0A.<br />
➋ Magnetic trip is fixed at 13x the maximum value of the current adjustment range.<br />
➌ CXU7 may be applied to single phase loads. Contact factory for these applications.<br />
➍ A red and yellow handle may be selected instead of the standard gray and black<br />
handle. Change “WG” suffix to “WJ”. Ex: Change CXU7-9-10-✱-0.16A-A10-WG to<br />
CXU7-9-10-✱-0.16A-A10-WJ.<br />
➎ Other voltages available, see Section A in this catalog. Non-standard coil voltages<br />
not listed here must be ordered and installed separately as renewal parts.<br />
➏ See F76 for dimensional information.<br />
F<br />
<strong>Motor</strong> <strong>Circuit</strong><br />
<strong>Controllers</strong><br />
Encl.<br />
Discount Schedule A-1<br />
F69
Non-Reversing Combination Controller, DC<br />
Enclosed Series CX7<br />
F<br />
<strong>Motor</strong> <strong>Circuit</strong><br />
<strong>Controllers</strong><br />
Encl.<br />
Enclosed Non-Reversing Combination Controller, True DC Coil - Type 4 / 12<br />
Max. Horsepower ➊➋➌<br />
Three Phase<br />
Amp / Horsepower<br />
Rating<br />
200V 230V 460V 575V<br />
O/L Relay<br />
Ampere<br />
Range<br />
Magnetic<br />
Response<br />
Current<br />
Painted Steel, Type 4 / 12 Enclosure<br />
Catalog Number ➍<br />
KTA7-25S Standard Interrupting Capacity<br />
~ ~ ~ ~ 0.10…0.16 2.1 CX7-9C-10-✱-AS0.16A-A10-WG 685 W6<br />
~ ~ ~ ~ 0.16…0.25 3.3 CX7-9C-10-✱-AS0.25A-A10-WG 685 W6<br />
~ ~ ~ ~ 0.25…0.40 5.2 CX7-9C-10-✱-AS0.4A-A10-WG 685 W6<br />
~ ~ ~ ~ 0.40…0.63 8.2 CX7-9C-10-✱-AS0.63A-A10-WG 705 W6<br />
~ ~ 1/2 3/4 0.63…1.0 13 CX7-9C-10-✱-AS1A-A10-WG 705 W6<br />
~ ~ 1 1 1.0…1.6 21 CX7-9C-10-✱-AS1.6A-A10-WG 705 W6<br />
1/2 3/4 1-1/2 2 1.6…2.5 33 CX7-9C-10-✱-AS2.5A-A10-WG 705 W6<br />
1 1 3 3 2.5…4 52 CX7-9C-10-✱-AS4A-A10-WG 705 W6<br />
1-1/2 2 5 ~ 4…6.3 82 CX7-9C-10-✱-AS6.3A-A10-WG 705 W6<br />
3 3 7-1/2 ~ 6.3…10 130 CX7-12C-10-✱-AS10A-A10-WG 746 W6<br />
3 5 10 ~ 10…16 208 CX7-16C-10-✱-AS16A-A10-WG 792 W6<br />
5 7-1/2 15 ~ 14.5…20 260 CX7-23C-10-✱-AS20A-A10-WG 818 W6<br />
KTA7-25H Standard Interrupting Capacity<br />
1/2 3/4 1-1/2 2 1.6…2.5 33 CX7-9C-10-✱-AH2.5A-A10-WG 742 W6<br />
1 1 3 3 2.5…4 52 CX7-9C-10-✱-AH4A-A10-WG 742 W6<br />
1-1/2 2 5 5 4…6.3 82 CX7-9C-10-✱-AH6.3A-A10-WG 742 W6<br />
3 3 7-1/2 10 6.3…10 130 CX7-12C-10-✱-AH10A-A10-WG 811 W6<br />
3 5 10 15 10…16 208 CX7-16C-10-✱-AH16A-A10-WG 835 W6<br />
5 7-1/2 15 ~ 14.5…20 260 CX7-23C-10-✱-AH20A-A10-WG 861 W6<br />
7-1/2 7-1/2 15 ~ 18…25 325 CX7-23C-10-✱-AH25A-A10-WG 861 W6<br />
KTA7-45H Standard Interrupting Capacity<br />
3 3 7-1/2 10 6.3…10 130 CX7-30C-10-✱-AH10A-A10-WG 1039 W7<br />
3 5 10 15 10…16 208 CX7-30C-10-✱-AH16A-A10-WG 1039 W7<br />
5 7-1/2 15 20 14.5…20 260 CX7-30C-10-✱-AH20A-A10-WG 1039 W7<br />
5 7-1/2 20 25 18…25 325 CX7-30C-10-✱-AH25A-A10-WG 1039 W7<br />
7-1/2 10 20 25 23…32 416 CX7-30C-10-✱-AH32A-A10-WG 1000 W7<br />
10 10 25 30 32…45 585 CX7-37C-10-✱-AH45A-A10-WG 1131 W7<br />
10 15 30 ~ 32…45 585 CX7-43C-10-✱-AH45A-A10-WG 1172 W7<br />
Ordering Instructions<br />
Specify Catalog Number<br />
Replace (✱) with Coil Code<br />
Select modifications if required<br />
See Coil Code tables on<br />
this page for codes<br />
Price<br />
Dimension<br />
Code<br />
Includes:<br />
• Type 12 / 4 enclosure - watertight, dustight<br />
• <strong>KT7</strong> “Type E” <strong>Motor</strong> Controller with 1 NO<br />
front mount Auxiliary Contact<br />
(Cat #: <strong>KT7</strong>-PE1-10)<br />
• Terminal Adaptor for Type E Applications<br />
(Cat.# <strong>KT7</strong>-25[45]-TE)<br />
• CA7 contactor (for remote operation),<br />
true DC coil<br />
• Power wiring<br />
• Gray and black Type 4/4X/12; IP66 handle<br />
(Cat.# <strong>KT7</strong>-HTN) ➍<br />
• Pilot device shown is factory installed option<br />
See page 72 for factory installed modifications<br />
Coil Codes (✱) ➎<br />
D.C.<br />
Coil Code<br />
12D<br />
24D<br />
48D<br />
110D<br />
220D<br />
Voltage<br />
12V<br />
24V<br />
48V<br />
110V<br />
220V<br />
➊ Horsepower ratings shown in the table above are<br />
for reference. The final selection of the manual<br />
starter depends on the actual motor full load current<br />
and service factor.<br />
• For motor with service factor less than 1.15. Use<br />
motor nameplate full load current times 0.9 and<br />
choose the motor starter with the appropriate<br />
current range. Example: <strong>Motor</strong> FLC = 4.2A; S.F. =<br />
1.0. 4.2A x 0.9 = 3.78A. Select catalog number<br />
KTA7-25S-4.0A.<br />
➋ Magnetic trip is fixed at 13x the maximum value of the current adjustment range.<br />
➌ CX7 may be applied to single phase loads. See footnote 1 for device selection criteria.<br />
To order single phase unit, change “CX7” in catalog number to “CBX7”. Three<br />
pole series connection will be provided. Ex: Change CX7-9-10-✱-0.16A-A10-WG<br />
to CBX7-9-10-✱-0.16A-A10-WJ.<br />
➍ A red and yellow handle may be selected instead of the standard gray and black<br />
handle. Change “WG” suffix to “WJ”. Ex: Change CX7-9-10-✱-0.16A-A10-WG to<br />
CX7-9-10-✱-0.16A-A10-WJ.<br />
➎ Other voltages available, see Section A in this catalog. Non-standard coil voltages<br />
not listed here must be ordered and installed separately as renewal parts.<br />
➏ See F76 for dimensional information.<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />
F70<br />
Discount Schedule A-1
Reversing Combination Controller, DC<br />
Enclosed Series CXU7<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />
Enclosed Reversing Combination Controller, True DC Coil - Type 4 / 12<br />
Max. Horsepower ➊➋➌<br />
Three Phase<br />
Amp / Horsepower<br />
Rating<br />
200V 230V 460V 575V<br />
O/L Relay<br />
Ampere<br />
Range<br />
Magnetic<br />
Response<br />
Current<br />
Painted Steel, Type 4 / 12 Enclosure<br />
Catalog Number ➍<br />
KTA7-25S Standard Interrupting Capacity<br />
~ ~ ~ ~ 0.10…0.16 2.1 CXU7-9C-22-✱-AS0.16A-A10-WG 752 W6<br />
~ ~ ~ ~ 0.16…0.25 3.3 CXU7-9C-22-✱-AS0.25A-A10-WG 752 W6<br />
~ ~ ~ ~ 0.25…0.40 5.2 CXU7-9C-22-✱-AS0.4A-A10-WG 752 W6<br />
~ ~ ~ ~ 0.40…0.63 8.2 CXU7-9C-22-✱-AS0.63A-A10-WG 772 W6<br />
~ ~ 1/2 3/4 0.63…1.0 13 CXU7-9C-22-✱-AS1A-A10-WG 772 W6<br />
~ ~ 1 1 1.0…1.6 21 CXU7-9C-22-✱-AS1.6A-A10-WG 772 W6<br />
1/2 3/4 1-1/2 2 1.6…2.5 33 CXU7-9C-22-✱-AS2.5A-A10-WG 772 W6<br />
1 1 3 3 2.5…4 52 CXU7-9C-22-✱-AS4A-A10-WG 772 W6<br />
1-1/2 2 5 ~ 4…6.3 82 CXU7-9C-22-✱-AS6.3A-A10-WG 772 W6<br />
3 3 7-1/2 ~ 6.3…10 130 CXU7-12C-22-✱-AS10A-A10-WG 826 W6<br />
3 5 10 ~ 10…16 208 CXU7-16C-22-✱-AS16A-A10-WG 878 W6<br />
5 7-1/2 15 ~ 14.5…20 260 CXU7-23C-22-✱-AS20A-A10-WG 910 W6<br />
KTA7-25H Standard Interrupting Capacity<br />
1/2 3/4 1-1/2 2 1.6…2.5 33 CXU7-9C-22-✱-AH2.5A-A10-WG 810 W6<br />
1 1 3 3 2.5…4 52 CXU7-9C-22-✱-AH4A-A10-WG 810 W6<br />
1-1/2 2 5 5 4…6.3 82 CXU7-9C-22-✱-AH6.3A-A10-WG 810 W6<br />
3 3 7-1/2 10 6.3…10 130 CXU7-12C-22-✱-AH10A-A10-WG 891 W6<br />
3 5 10 15 10…16 208 CXU7-16C-22-✱-AH16A-A10-WG 921 W6<br />
5 7-1/2 15 ~ 14.5…20 260 CXU7-23C-22-✱-AH20A-A10-WG 953 W6<br />
7-1/2 7-1/2 15 ~ 18…25 325 CXU7-23C-22-✱-AH25A-A10-WG 953 W6<br />
KTA7-45H Standard Interrupting Capacity<br />
3 3 7-1/2 10 6.3…10 130 CXU7-30C-22-✱-AH10A-A10-WG 1118 W7<br />
3 5 10 15 10…16 208 CXU7-30C-22-✱-AH16A-A10-WG 1118 W7<br />
5 7-1/2 15 20 14.5…20 260 CXU7-30C-22-✱-AH20A-A10-WG 1118 W7<br />
5 7-1/2 20 25 18…25 325 CXU7-30C-22-✱-AH25A-A10-WG 1118 W7<br />
7-1/2 10 20 25 23…32 416 CXU7-30C-22-✱-AH32A-A10-WG 1200 W7<br />
10 10 25 30 32…45 585 CXU7-37C-22-✱-AH45A-A10-WG 1275 W7<br />
10 15 30 ~ 32…45 585 CXU7-43C-22-✱-AH45A-A10-WG 1319 W7<br />
Ordering Instructions<br />
Specify Catalog Number<br />
Replace (✱) with Coil Code<br />
Select modifications if required<br />
See Coil Code tables on<br />
this page for codes<br />
Price<br />
Dimension<br />
Code<br />
Includes:<br />
• Type 12 / 4 enclosure - watertight, dustight<br />
• <strong>KT7</strong> “Type E” <strong>Motor</strong> Controller with 1 NO<br />
front mount Auxiliary Contact<br />
(Cat #: <strong>KT7</strong>-PE1-10)<br />
• Terminal Adaptor for Type E Applications<br />
(Cat.# <strong>KT7</strong>-25[45]-TE)<br />
• CA7 contactors (for remote operation),<br />
true DC coil<br />
• Power wiring<br />
• Gray and black Type 4/4X/12; IP66 handle<br />
(Cat.# <strong>KT7</strong>-HTN) ➍<br />
• Control power transformer, pilot device,<br />
terminals and other equipment shown are<br />
factory installed options<br />
See page 72 for factory installed modifications<br />
Coil Codes (✱) ➎<br />
D.C.<br />
Coil Code<br />
12D<br />
24D<br />
48D<br />
110D<br />
220D<br />
Voltage<br />
12V<br />
24V<br />
48V<br />
110V<br />
220V<br />
➊ Horsepower ratings shown in the table above are<br />
for reference. The final selection of the manual<br />
starter depends on the actual motor full load current<br />
and service factor.<br />
• For motor with service factor less than 1.15. Use<br />
motor nameplate full load current times 0.9 and<br />
choose the motor starter with the appropriate<br />
current range. Example: <strong>Motor</strong> FLC = 4.2A; S.F. =<br />
1.0. 4.2A x 0.9 = 3.78A. Select catalog number<br />
KTA7-25S-4.0A.<br />
➋ Magnetic trip is fixed at 13x the maximum value of the current adjustment range.<br />
➌ CXU7 may be applied to single phase loads. Contact factory for these applications.<br />
➍ A red and yellow handle may be selected instead of the standard gray and black<br />
handle. Change “WG” suffix to “WJ”. Ex: Change CXU7-9-10-✱-0.16A-A10-WG to<br />
CXU7-9-10-✱-0.16A-A10-WJ.<br />
➎ Other voltages available, see Section A in this catalog. Non-standard coil voltages<br />
not listed here must be ordered and installed separately as renewal parts.<br />
➏ See F76 for dimensional information.<br />
F<br />
<strong>Motor</strong> <strong>Circuit</strong><br />
<strong>Controllers</strong><br />
Encl.<br />
Discount Schedule A-1<br />
F71
Enclosed Combination Controller<br />
Modifications<br />
F<br />
<strong>Motor</strong> <strong>Circuit</strong><br />
<strong>Controllers</strong><br />
Non-Reversing and Reversing Combination Controller Modifications (Factory Assembled)<br />
Description<br />
Pilot Devices ➊<br />
Add Suffix to<br />
Catalog Number<br />
Price<br />
Adder<br />
START-STOP multi-function pushbutton -3U 115<br />
ON-OFF multi-function pushbutton -4U 115<br />
FOR-STOP-REV multi-function pushbutton -3U 210<br />
UP-STOP-DOWN multi-function pushbutton -4U 210<br />
OPEN-STOP-CLOSE multi-function pushbutton -5U 210<br />
HAND-AUTO selector switch -5 115<br />
OFF-ON selector switch -6 115<br />
HAND-OFF-AUTO selector switch -7 115<br />
FOR-OFF-REV selector switch -6 115<br />
UP-OFF-DOWN selector switch -7 115<br />
OPEN-OFF-CLOSE selector switch -8 115<br />
Pilot light only -1 80<br />
Pilot lights only (2) -2 155<br />
Pilot light w/ START-STOP multi-function pushbutton -13U 195<br />
Pilot light w/ ON-OFF multi-function pushbutton -14U 195<br />
Pilot light w/ HAND-AUTO selector switch -15 195<br />
Pilot light w/ OFF-ON selector switch -16 195<br />
Pilot light w/ HAND-OFF-AUTO selector switch -17 195<br />
Control Power Transformer (with fused secondary)<br />
Primary volts Secondary volts<br />
50 watt<br />
Standard<br />
Capacity<br />
208 120 -XA 140<br />
240 120 -XB 140<br />
480 120 -XC 140<br />
575 120 -XD 140<br />
380 110 -XG 140<br />
240 24 -XE 140<br />
480 24 -XF 140<br />
<strong>KT7</strong> Auxiliaries & Trip Contacts - Front Mount<br />
1 NO Auxiliary -A10 33<br />
1 NC Auxiliary -A01 33<br />
1 NO + 1 NC Auxiliary -A11 37<br />
2 NO Auxiliaries -A20 37<br />
1 NO Trip + 1 NC Auxiliary -T10A01 47<br />
1 NO Trip + 1 NO Auxiliary -T10A10 47<br />
<strong>KT7</strong> Auxiliaries - Side Mount<br />
2 NC Auxiliaries -AS02 47<br />
2 NO Auxiliaries -AS20 47<br />
1 NO + 1 NC Auxiliary -AS11 47<br />
Additional <strong>KT7</strong> Trip Contacts - Side Mount<br />
1 NO Thermal-Mag + 1 NO Mag Only -R00 56<br />
1 NO Thermal-Mag + 1 NC Mag Only -R01 56<br />
1 NC Thermal-Mag + 1 NO Mag Only -R10 56<br />
<strong>KT7</strong> Accessories<br />
Undervoltage Release Module<br />
Select coil voltage<br />
from table at right -UA-✱ 75<br />
Description<br />
Add Suffix to<br />
Catalog Number<br />
Price<br />
Adder<br />
Shunt Release Module -<strong>AA</strong>-✱ 75<br />
CA7 Auxiliary Contacts<br />
1 NO Auxiliary -S10 27<br />
1 NC Auxiliary -S01 27<br />
1 NO + 1 NC Auxiliary -S11 34<br />
2 NO Auxiliaries -S20 34<br />
2 NC Auxiliaries -S02 34<br />
1 NO + 2 NC Auxiliary -S12 38<br />
2 NO + 1 NC Auxiliary -S21 38<br />
3 NO Auxiliaries -S30 38<br />
3 NC Auxiliaries -S03 38<br />
1 NO + 3 NC Auxiliary -S13 45<br />
3 NO + 1 NC Auxiliary -S31 45<br />
2 NO + 2 NC Auxiliary -S22 45<br />
4 NO Auxiliaries -S40 45<br />
4 NC Auxiliaries -S04 45<br />
Alternate Aux. Contact Arrangement (CA7 only)<br />
1 NC in lieu of standard 1 NO -SX10 10<br />
2 NC in lieu of standard 2 NO (on CXU7 only) -SX2 10<br />
CA7 Contactor Accessories<br />
Electronic Interface -JE 56<br />
Surge Suppressor RC -C 32<br />
Surge Suppressor Varistor -V 24<br />
Surge Suppressor Diode -D 31<br />
Unwired Terminal Blocks Specify quantity (▼) -▼TB 13<br />
Coil Selection (✱)<br />
Coil Voltage Range<br />
Code 50 Hz 60 Hz<br />
24V 21V 24V<br />
28V 24V 28V<br />
120V 105V 120V<br />
127V 110V 127V<br />
230V 220...230V ~<br />
240V ~ 240...260V<br />
277V 240V 277V<br />
460V 380...400V 400...460V<br />
480V 415V 480V<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />
Encl.<br />
➊ Multi-function pushbuttons with protective boots are supplied as standard (all<br />
suffix’s ending in “U”). See Section H in this catalog for description.<br />
F72<br />
Discount Schedule A-1
<strong>Manual</strong> <strong>Motor</strong> Controller<br />
Explosion-Proof Series KTA7<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />
KTA7 Explosion Proof <strong>Motor</strong> <strong>Controllers</strong> - Type 7 / 9<br />
Max. Horsepower ➊➋➌<br />
Three Phase<br />
200V 230V 460V 575V<br />
Amp / Horsepower<br />
Rating<br />
O/L Relay<br />
Ampere<br />
Range<br />
Modifications (Factory Assembled)<br />
Magnetic<br />
Response<br />
Current<br />
➊ Horsepower ratings shown in the table above are for reference. The final<br />
selection of the manual starter depends on the actual motor full load current<br />
and service factor.<br />
• For motor with service factor less than 1.15. Use motor nameplate full load<br />
current times 0.9 and choose the motor starter with the appropriate current<br />
range. Example: <strong>Motor</strong> FLC = 4.2A; S.F. = 1.0. 4.2A x 0.9 = 3.78A. Select<br />
catalog number KTA7-25S-4.0A.<br />
➋ Magnetic trip is fixed at 13x the maximum value of the current adjustment range.<br />
➌ KTA7 may be applied to single phase loads if 3 poles of device are wired in series.<br />
See footnote ➊ for device selection criteria.<br />
➍ KTA7-25S-25A is suitable for use as a manual motor starter only because the<br />
KTA7-25S-25A is not type E rated. Additional units on this page may be applicable<br />
as a manual motor starter only (i.e. @ 575V).<br />
➎ See F76 for dimensional information.<br />
Explosion Proof - Type 7 / 9 Enclosure<br />
Catalog Number<br />
Price<br />
KTA7-25S Standard Interrupting Capacity<br />
~ ~ ~ ~ 0.10…0.16 2.1 KTA7-25S-0.16A-EX 508 EX<br />
~ ~ ~ ~ 0.16…0.25 3.3 KTA7-25S-0.25A-EX 508 EX<br />
~ ~ ~ ~ 0.25…0.40 5.2 KTA7-25S-0.4A-EX 508 EX<br />
~ ~ ~ ~ 0.40…0.63 8.2 KTA7-25S-0.63A-EX 529 EX<br />
~ ~ 1/2 3/4 0.63…1.0 13 KTA7-25S-1A-EX 529 EX<br />
~ ~ 1 1 1.0…1.6 21 KTA7-25S-1.6A-EX 529 EX<br />
1/2 3/4 1-1/2 2 1.6…2.5 33 KTA7-25S-2.5A-EX 529 EX<br />
1 1 3 3 2.5…4 52 KTA7-25S-4A-EX 529 EX<br />
1-1/2 2 5 ~ 4…6.3 82 KTA7-25S-6.3A-EX 529 EX<br />
3 3 7-1/2 ~ 6.3…10 130 KTA7-25S-10A-EX 529 EX<br />
3 5 10 ~ 10…16 208 KTA7-25S-16A-EX 551 EX<br />
5 7-1/2 15 ~ 14.5…20 260 KTA7-25S-20A-EX 551 EX<br />
7-1/2 7-1/2 15 20 18…25 325 KTA7-25S-25-EX ➍ 551 EX<br />
Description<br />
<strong>KT7</strong> Auxiliaries & Trip Contacts - Front Mount<br />
1 NO Auxiliary<br />
1 NC Auxiliary<br />
1 NO + 1 NC Auxiliary<br />
2 NO Auxiliaries<br />
1 NO Trip + 1 NC Auxiliary<br />
1 NO Trip + 1 NO Auxiliary<br />
Add Suffix to<br />
Catalog Number<br />
-A10<br />
-A01<br />
-A11<br />
-A20<br />
-T10A01<br />
-T10A10<br />
Price<br />
Adder<br />
33<br />
33<br />
37<br />
37<br />
47<br />
47<br />
Enclosure Modifications<br />
Breather/Drain -BD 65<br />
Dimension<br />
Code<br />
Includes:<br />
• Class I, Group C & D –<br />
Class II, Group E, F & G enclosure<br />
• <strong>KT7</strong> “Type E” Self-protected <strong>Manual</strong> <strong>Motor</strong><br />
Controller (Standard interrupting capacity)<br />
• Terminal Adaptor for Type E Applications<br />
(Cat.# <strong>KT7</strong>-25-TE)<br />
F<br />
<strong>Motor</strong> <strong>Circuit</strong><br />
<strong>Controllers</strong><br />
Encl.<br />
Discount Schedule A-1<br />
F73
Self-protected <strong>Manual</strong> <strong>Motor</strong> Controller<br />
Explosion-Proof Series KTA7<br />
F<br />
<strong>Motor</strong> <strong>Circuit</strong><br />
<strong>Controllers</strong><br />
Encl.<br />
KTA7 Explosion Proof <strong>Motor</strong> <strong>Controllers</strong> – Type 7 / 9 with Type 4 Gaskets<br />
Max. Horsepower ➊➋➌<br />
Three Phase<br />
Amp / Horsepower<br />
Rating<br />
200V 230V 460V 575V<br />
O/L Relay<br />
Ampere<br />
Range<br />
Magnetic<br />
Response<br />
Current<br />
➊ Horsepower ratings shown in the table above are for reference. The final<br />
selection of the manual starter depends on the actual motor full load current<br />
and service factor.<br />
• For motor with service factor less than 1.15. Use motor nameplate full load<br />
current times 0.9 and choose the motor starter with the appropriate current<br />
range. Example: <strong>Motor</strong> FLC = 4.2A; S.F. = 1.0. 4.2A x 0.9 = 3.78A. Select<br />
catalog number KTA7-25S-4.0A.<br />
➋ Magnetic trip is fixed at 13x the maximum value of the current adjustment range.<br />
➌ KTA7 may be applied to single phase loads if 3 poles of device are wired in series.<br />
See footnote ➊ for device selection criteria.<br />
➍ See F76 for dimensional information.<br />
Explosion Proof - Type 7 / 9 Enclosure<br />
(with Type 4 Gaskets)<br />
Catalog Number<br />
KTA7-25S Standard Interrupting Capacity<br />
~ ~ ~ ~ 0.10…0.16 2.1 KTA7-25S-0.16A-EY 733 EY<br />
~ ~ ~ ~ 0.16…0.25 3.3 KTA7-25S-0.25A-EY 733 EY<br />
~ ~ ~ ~ 0.25…0.40 5.2 KTA7-25S-0.4A-EY 733 EY<br />
~ ~ ~ ~ 0.40…0.63 8.2 KTA7-25S-0.63A-EY 754 EY<br />
~ ~ 1/2 3/4 0.63…1.0 13 KTA7-25S-1A-EY 754 EY<br />
~ ~ 1 1 1.0…1.6 21 KTA7-25S-1.6A-EY 754 EY<br />
1/2 3/4 1-1/2 2 1.6…2.5 33 KTA7-25S-2.5A-EY 754 EY<br />
1 1 3 3 2.5…4 52 KTA7-25S-4A-EY 754 EY<br />
1-1/2 2 5 ~ 4…6.3 82 KTA7-25S-6.3A-EY 754 EY<br />
3 3 7-1/2 ~ 6.3…10 130 KTA7-25S-10A-EY 754 EY<br />
3 5 10 ~ 10…16 208 KTA7-25S-16A-EY 776 EY<br />
5 7-1/2 15 ~ 14.5…20 260 KTA7-25S-20A-EY 776 EY<br />
KTA7-25H Standard Interrupting Capacity<br />
1/2 3/4 1-1/2 2 1.6…2.5 33 KTA7-25H-2.5A-EY 793 EY<br />
1 1 3 3 2.5…4 52 KTA7-25H-4A-EY 793 EY<br />
1-1/2 2 5 5 4…6.3 82 KTA7-25H-6.3A-EY 793 EY<br />
3 3 7-1/2 10 6.3…10 130 KTA7-25H-10A-EY 820 EY<br />
3 5 10 15 10…16 208 KTA7-25H-16A-EY 820 EY<br />
5 7-1/2 15 ~ 14.5…20 260 KTA7-25H-20A-EY 820 EY<br />
7-1/2 7-1/2 15 ~ 18…25 325 KTA7-25H-25A-EY 820 EY<br />
KTA7-45H Standard Interrupting Capacity<br />
3 3 7-1/2 10 6.3…10 130 KTA7-45H-10A-EZ 1159 EZ<br />
3 5 10 15 10…16 208 KTA7-45H-16A-EZ 1159 EZ<br />
5 7-1/2 15 20 14.5…20 260 KTA7-45H-20A-EZ 1159 EZ<br />
5 7-1/2 20 25 18…25 325 KTA7-45H-25A-EZ 1159 EZ<br />
10 10 25 30 23…32 416 KTA7-45H-32A-EZ 1197 EZ<br />
15 15 30 ~ 32…45 585 KTA7-45H-45A-EZ 1197 EZ<br />
Price<br />
Dimension<br />
Code<br />
Includes:<br />
• Class I, Group B, C & D –<br />
Class II, Group E, F & G enclosure<br />
• <strong>KT7</strong> “Type E” Self-protected <strong>Manual</strong> <strong>Motor</strong><br />
Controller (Standard interrupting capacity)<br />
• Terminal Adaptor for Type E Applications<br />
(Cat.# <strong>KT7</strong>-25[45]-TE)<br />
Modifications (Factory Assembled)<br />
Description<br />
<strong>KT7</strong> Auxiliaries & Trip<br />
Contacts - Front Mount<br />
1 NO Auxiliary<br />
1 NC Auxiliary<br />
1 NO + 1 NC Auxiliary<br />
2 NO Auxiliaries<br />
1 NO Trip + 1 NC Auxiliary<br />
1 NO Trip + 1 NO Auxiliary<br />
<strong>KT7</strong> Auxiliaries - Side Mount<br />
2 NC Auxiliaries<br />
2 NO Auxiliaries<br />
1 NO + 1 NC Auxiliary<br />
Coil Selection (✱)<br />
Coil Voltage Range<br />
Code 50 Hz 60 Hz<br />
24V 21V 24V<br />
28V 24V 28V<br />
120V 105V 120V<br />
127V 110V 127V<br />
230V 220...230V ~<br />
240V ~ 240...260V<br />
277V 240V 277V<br />
460V 380...400V 400...460V<br />
480V 415V 480V<br />
Add Suffix to<br />
Cat. Number<br />
-A10<br />
-A01<br />
-A11<br />
-A20<br />
-T10A01<br />
-T10A10<br />
-AS02<br />
-AS20<br />
-AS11<br />
Additional <strong>KT7</strong> Trip Contacts,<br />
Side Mount<br />
1 NO Thermal-Mag+1 NO Mag -R00<br />
1 NO Thermal-Mag+1 NC Mag -R01<br />
1 NC Thermal-Mag+1 NO Mag -R10<br />
Accessories<br />
Undervoltage Release Module<br />
Shunt Release Module<br />
Select coil voltage from table below<br />
-UA-✱<br />
-<strong>AA</strong>-✱<br />
Price<br />
Adder<br />
33<br />
33<br />
37<br />
37<br />
47<br />
47<br />
47<br />
47<br />
47<br />
56<br />
56<br />
56<br />
75<br />
75<br />
Enclosure Modifications<br />
Breather/Drain -BD 65<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />
F74<br />
Discount Schedule A-1
Combination Controller<br />
Explosion-Proof Series CX7<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />
CX7 Explosion Proof Combination <strong>Controllers</strong> - Type 7 / 9<br />
Max. Horsepower ➊➋➌<br />
Three Phase<br />
Amp / Horsepower<br />
Rating<br />
200V 230V 460V 575V<br />
O/L Relay<br />
Ampere<br />
Range<br />
Magnetic<br />
Response<br />
Current<br />
➊ Horsepower ratings shown in the table above are for reference. The final<br />
selection of the manual starter depends on the actual motor full load current<br />
and service factor.<br />
• For motor with service factor less than 1.15. Use motor nameplate full load<br />
current times 0.9 and choose the motor starter with the appropriate current<br />
range. Example: <strong>Motor</strong> FLC = 4.2A; S.F. = 1.0. 4.2A x 0.9 = 3.78A. Select<br />
catalog number KTA7-25S-4.0A.<br />
➋ Magnetic trip is fixed at 13x the maximum value of the current adjustment range.<br />
➌ CX7 may be applied to single phase loads. See footnote 1 for device selection criteria.<br />
To order single phase unit, change “CX7” in catalog number to “CBX7”. Three<br />
pole series connection will be provided. Ex: Change CX7-9-10-✱-0.16A-A10-WG<br />
to CBX7-9-10-✱-0.16A-A10-WJ.<br />
➍ See F76 for dimensional information.<br />
Explosion Proof - Type 7 / 9 Enclosure<br />
(with Type 4 Gaskets)<br />
Catalog Number<br />
KTA7-25S Standard Interrupting Capacity<br />
~ ~ ~ ~ 0.10…0.16 2.1 CX7-9-10-✱-AS0.16A-A10-EZ 1071 EZ<br />
~ ~ ~ ~ 0.16…0.25 3.3 CX7-9-10-✱-AS0.25A-A10-EZ 1071 EZ<br />
~ ~ ~ ~ 0.25…0.40 5.2 CX7-9-10-✱-AS0.4A-A10-EZ 1071 EZ<br />
~ ~ ~ ~ 0.40…0.63 8.2 CX7-9-10-✱-AS0.63A-A10-EZ 1092 EZ<br />
~ ~ 1/2 3/4 0.63…1.0 13 CX7-9-10-✱-AS1A-A10-EZ 1092 EZ<br />
~ ~ 1 1 1.0…1.6 21 CX7-9-10-✱-AS1.6A-A10-EZ 1092 EZ<br />
1/2 3/4 1-1/2 2 1.6…2.5 33 CX7-9-10-✱-AS2.5A-A10-EZ 1092 EZ<br />
1 1 3 3 2.5…4 52 CX7-9-10-✱-AS4A-A10-EZ 1092 EZ<br />
1-1/2 2 5 ~ 4…6.3 82 CX7-9-10-✱-AS6.3A-A10-EZ 1092 EZ<br />
3 3 7-1/2 ~ 6.3…10 130 CX7-12-10-✱-AS10A-A10-EZ 1112 EZ<br />
3 5 10 ~ 10…16 208 CX7-16-10-✱-AS16A-A10-EZ 1146 EZ<br />
5 7-1/2 15 ~ 14.5…20 260 CX7-23-10-✱-AS20A-A10-EZ 1158 EZ<br />
KTA7-25H Standard Interrupting Capacity<br />
1/2 3/4 1-1/2 2 1.6…2.5 33 CX7-9-10-✱-AH2.5A-A10-EZ 1131 EZ<br />
1 1 3 3 2.5…4 52 CX7-9-10-✱-AH4A-A10-EZ 1131 EZ<br />
1-1/2 2 5 5 4…6.3 82 CX7-9-10-✱-AH6.3A-A10-EZ 1131 EZ<br />
3 3 7-1/2 10 6.3…10 130 CX7-12-10-✱-AH10A-A10-EZ 1178 EZ<br />
3 5 10 15 10…16 208 CX7-16-10-✱-AH16A-A10-EZ 1190 EZ<br />
5 7-1/2 15 ~ 14.5…20 260 CX7-23-10-✱-AH20A-A10-EZ 1202 EZ<br />
7-1/2 7-1/2 15 ~ 18…25 325 CX7-23-10-✱-AH25A-A10-EZ 1202 EZ<br />
KTA7-45H Standard Interrupting Capacity<br />
3 3 7-1/2 10 6.3…10 130 CX7-30-10-✱-AH10A-A10-EZ 1318 EZ<br />
3 5 10 15 10…16 208 CX7-30-10-✱-AH16A-A10-EZ 1318 EZ<br />
5 7-1/2 15 20 14.5…20 260 CX7-30-10-✱-AH20A-A10-EZ 1318 EZ<br />
5 7-1/2 20 25 18…25 325 CX7-30-10-✱-AH25A-A10-EZ 1318 EZ<br />
7-1/2 10 20 25 23…32 416 CX7-30-10-✱-AH32A-A10-EZ 1340 EZ<br />
10 10 25 30 32…45 585 CX7-37-10-✱-AH45A-A10-EZ 1381 EZ<br />
15 15 30 ~ 32…45 585 CX7-43-10-✱-AH45A-A10-EZ 1393 EZ<br />
Price<br />
Dimension<br />
Code<br />
Includes:<br />
• Class I, Group B, C & D –<br />
Class II, Group E, F & G enclosure<br />
• <strong>KT7</strong> “Type E” Self-protected <strong>Manual</strong> <strong>Motor</strong><br />
Controller with 1 NO front mount auxiliary<br />
contact (Cat.# <strong>KT7</strong>-PE1-10)<br />
• Terminal Adaptor for Type E Applications<br />
(Cat.# <strong>KT7</strong>-25[45]-TE)<br />
• CA7 contactor (for remote operation), AC coil<br />
• Power wiring<br />
Coil Codes (✱) ➍<br />
A.C.<br />
Coil Code<br />
Voltage Range<br />
50 Hz 60 Hz<br />
24Z 24V 24V<br />
120 110V 120V<br />
208 ~ 208V<br />
220W ~ 208V-240V<br />
240 220V 240V<br />
277 240V 277V<br />
380 380...400V 440V<br />
480 440V 480V<br />
600 550V 600V<br />
Modifications (Factory Assembled)<br />
Description<br />
<strong>KT7</strong> Auxiliaries & Trip<br />
Contacts - Front Mount<br />
1 NO Auxiliary<br />
1 NC Auxiliary<br />
1 NO + 1 NC Auxiliary<br />
2 NO Auxiliaries<br />
1 NO Trip + 1 NC Auxiliary<br />
1 NO Trip + 1 NO Auxiliary<br />
Description<br />
CA7 Contactor Auxiliaries<br />
1 NC Auxiliary<br />
1 NO Auxiliary<br />
CA7 Contactor Accessories<br />
Electronic Interface<br />
Surge Suppressor RC<br />
Surge Suppressor Varistor<br />
Surge Suppressor Diode<br />
Enclosure Modifications<br />
Dual START/STOP pushbutton<br />
ON/OFF selector switch<br />
H-O-A<br />
Breather/Drain<br />
Change “A10”<br />
in Cat. # to...<br />
-A10<br />
-A01<br />
-A11<br />
-A20<br />
-T10A01<br />
-T10A10<br />
Add Suffix to<br />
Cat. Number<br />
-S01<br />
-S10<br />
-JE<br />
-R<br />
-V<br />
-D<br />
Price<br />
Adder<br />
33<br />
33<br />
37<br />
37<br />
47<br />
47<br />
Price<br />
Adder<br />
➍ Other voltages available, see Section A in this catalog. Non-standard coil voltages<br />
not listed here must be ordered and installed separately as renewal parts.<br />
Ordering Instructions<br />
Specify Catalog Number<br />
Replace (✱) with Coil Code<br />
Select modifications if required<br />
-3<br />
-6<br />
-7<br />
-BD<br />
27<br />
27<br />
56<br />
32<br />
24<br />
31<br />
115<br />
115<br />
115<br />
65<br />
See Coil Code tables on<br />
this page for codes<br />
F<br />
<strong>Motor</strong> <strong>Circuit</strong><br />
<strong>Controllers</strong><br />
Encl.<br />
Discount Schedule A-1<br />
F75
Dimensions<br />
Enclosed Series <strong>KT7</strong> <strong>Motor</strong> Controller<br />
F<br />
<strong>Motor</strong> <strong>Circuit</strong><br />
<strong>Controllers</strong><br />
• Dimensions are shown in decimal inches.<br />
• Dimensions are not intended to be used for manufacturing purposes.<br />
Enclosures<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />
Encl.<br />
F76<br />
Discount Schedule A-1
Wiring Diagrams<br />
<strong>KT7</strong> <strong>Motor</strong> <strong>Circuit</strong> Controller<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />
Single, Two and Three Phase Connection Diagram<br />
F<br />
<strong>Motor</strong> <strong>Circuit</strong><br />
<strong>Controllers</strong><br />
Encl.<br />
Discount Schedule A-1<br />
F77
Technical Information<br />
IP Ratings Definitions<br />
IP Ratings Definitions<br />
F<br />
<strong>Motor</strong> <strong>Circuit</strong><br />
<strong>Controllers</strong><br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />
Encl.<br />
F78<br />
Discount Schedule A-1
Technical Information<br />
Ratings Definitions<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />
NEMA / UL Type Definitions<br />
NEMA / UL Type<br />
Indoor Use Outdoor Use Indoor or Outdoor Use<br />
For a degree of protection against: 1 12 13 3R 3 4 4X 6P 6<br />
Incidental contact with enclosed equipment • • • • • • • • •<br />
Falling dirt • • • • • • • • •<br />
Rust • • • • • • • • •<br />
Circulating dust, lint, fibers and flyings • • • • • • •<br />
Windblown dust • • • • •<br />
Falling liquids and light splashing • • • • • • •<br />
Rain (limited water allowed inside) • • • • • •<br />
Rain (no water allowed inside) • • • • •<br />
Snow and sleet • • • • • •<br />
Hosedown and splashing water • • • •<br />
Occasional prolonged submersion • •<br />
Oil or coolant spraying or splashing<br />
•<br />
Corrosive agents • •<br />
Occasional temporary submersion • •<br />
F<br />
<strong>Motor</strong> <strong>Circuit</strong><br />
<strong>Controllers</strong><br />
Encl.<br />
Discount Schedule A-1<br />
F79
<strong>Motor</strong> Current Rating Chart<br />
F<br />
<strong>Motor</strong> <strong>Circuit</strong><br />
<strong>Controllers</strong><br />
Encl.<br />
60 Hz AC Induction <strong>Motor</strong><br />
Horsepower<br />
Single Phase<br />
Three Phase<br />
115 Volt 230 Volt 200 Volt 230 Volt 380-415 Volt 460 Volt 575 Volt<br />
1/6 4.4 2.2 ~ ~ ~ ~<br />
1/4 5.8 2.9 ~ ~ ~ ~<br />
1/3 7.2 3.6 ~ ~ ~ ~<br />
1/2 9.8 4.9 2.5 2.2 1.3 1.1 0.9<br />
3/4 13.8 6.9 3.7 3.2 1.8 1.6 1.3<br />
1 16.0 8.0 4.8 4.2 2.3 2.1 1.7<br />
1 1/2 20.0 10.0 6.9 6.0 3.3 3.0 2.4<br />
2 24.0 12.0 7.8 6.8 4.3 3.4 2.7<br />
3 34.0 17.0 11.0 9.6 6.1 4.8 3.9<br />
5 56.0 28.0 17.5 15.2 9.7 7.6 6.1<br />
7 1/2 80.0 40.0 25.0 22.0 14.0 11.0 9.0<br />
10 100 50.0 32.0 28.0 18.0 14.0 11.0<br />
15 135 68.0 48.0 42.0 27.0 21.0 17.0<br />
20 ~ 88.0 62.0 54.0 34.0 27.0 22.0<br />
25 ~ 110 78.0 68.0 43.0 34.0 27.0<br />
30 ~ 136 92.0 80.0 51.0 40.0 32.0<br />
40 ~ 176 120 104 66.0 52.0 41.0<br />
50 ~ 216 150 130 83.0 65.0 52.0<br />
60 ~ ~ 177 154 103 77.0 62.0<br />
75 ~ ~ 221 192 128 96.0 77.0<br />
100 ~ ~ 285 248 165 124 99.0<br />
125 ~ ~ 359 312 125 156 125<br />
150 ~ ~ 414 360 150 180 144<br />
175 ~ ~ 475 413 275 207 168<br />
200 ~ ~ 552 480 320 240 192<br />
250 ~ ~ 692 602 403 302 242<br />
300 ~ ~ ~ ~ 482 361 289<br />
350 ~ ~ ~ ~ 560 414 336<br />
400 ~ ~ ~ ~ 636 477 382<br />
450 ~ ~ ~ ~ 711 515 412<br />
500 ~ ~ ~ ~ 786 590 472<br />
The information in this chart was derived from Table 430-148 &<br />
430-150 of the NEC and Table 50.1 of UL standard 508A. The voltages<br />
listed are rated motor voltages. The currents listed shall be permitted<br />
for system voltage ranges of 110-120, 220-240, 380-415, 440-480<br />
and 550-600 volts.<br />
The full-load current values are for motors running at usual speeds and<br />
motors with normal torque characteristics. <strong>Motor</strong>s built for especially<br />
low speeds or high torques may have higher full-load currents, and<br />
multi-speed motors will have full-load currents varying with speed. In<br />
these cases, the nameplate current ratings shall be used.<br />
Caution: The actual motor amps may be higher or lower than the<br />
average values listed above. For more reliable motor protection,<br />
use the actual motor current as listed on the motor nameplate.<br />
Use this table as a guide only<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />
F80<br />
Discount Schedule A-1
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />
Methods of Applying<br />
<strong>KT7</strong> <strong>Motor</strong> <strong>Circuit</strong> <strong>Controllers</strong><br />
This information is provided to aid in proper system design and utilization<br />
of the new <strong>KT7</strong> <strong>Motor</strong> <strong>Circuit</strong> Controller in North American applications. Be<br />
sure to consider all applicable local and national codes for your particular<br />
installation.<br />
F<br />
<strong>Motor</strong> <strong>Circuit</strong><br />
<strong>Controllers</strong><br />
Apps.<br />
F81
Application Notes<br />
Series <strong>KT7</strong> <strong>Motor</strong> <strong>Circuit</strong> <strong>Controllers</strong><br />
Methods of Applying <strong>KT7</strong> <strong>Motor</strong> <strong>Circuit</strong> <strong>Controllers</strong><br />
F<br />
<strong>Motor</strong> <strong>Circuit</strong><br />
<strong>Controllers</strong><br />
The <strong>KT7</strong> <strong>Motor</strong> <strong>Circuit</strong> Controller provides Class 10 overload protection,<br />
as well as, current limiting short-circuit protection for individual<br />
motor loads. <strong>KT7</strong>s are also approved for use as circuit breakers (per<br />
IEC 947-6-2) for applications outside of North America. In the United<br />
States and Canada, however, they are UL/CSA listed as <strong>Manual</strong> <strong>Starters</strong><br />
with optional approvals for <strong>Motor</strong> Disconnecting and Group <strong>Motor</strong><br />
applications.<br />
<strong>KT7</strong> <strong>Motor</strong> <strong>Circuit</strong> <strong>Controllers</strong> are also UL/CSA listed as <strong>Manual</strong> Combination<br />
(Type E) <strong>Starters</strong> eliminating the requirement for additional<br />
short-circuit protection in many applications. This reduces both panel<br />
space and cost in multi-motor installations and eliminates the restrictive<br />
NEC/CEC rules that pertained to <strong>Manual</strong> <strong>Starters</strong> used in Group <strong>Motor</strong><br />
applications.<br />
The following information is provided to aid in proper system design and<br />
utilization of the capabilities of the new <strong>KT7</strong> <strong>Motor</strong> <strong>Circuit</strong> Controller<br />
in North American applications. Please be sure to consider all applicable<br />
local and national codes for your particular installation.<br />
<strong>Circuit</strong> Breaker Applications – IEC<br />
<strong>KT7</strong> <strong>Motor</strong> <strong>Circuit</strong> <strong>Controllers</strong> are current limiting IEC circuit breakers<br />
(lEC 947-6-2) that also provide Class 10 motor overload protection. Additionally,<br />
they meet IEC requirements for applications such as:<br />
• Disconnector (lEC 947-2)<br />
• Main Switch (lEC 204-1)<br />
• Emergency Off (lEC 204-1)<br />
• Revision Service Switch (lEC 947)<br />
<strong>KT7</strong> <strong>Motor</strong> <strong>Circuit</strong> <strong>Controllers</strong> cannot be applied in North America as<br />
circuit breakers, since they do not meet the UL specifications for circuit<br />
breakers (UL 489).<br />
<strong>Manual</strong> Starter Applications — UL/CSA<br />
<strong>KT7</strong> <strong>Motor</strong> <strong>Circuit</strong> <strong>Controllers</strong> are an excellent choice for manual<br />
starting applications. As UL/CSA listed manual motor controllers, they<br />
provide motor overload protection, however, a separate short-circuit<br />
protective device must still be used. The fuse or circuit breaker used for<br />
the short-circuit protection may be sized to the maximum allowable per<br />
NEC Article 430-52 in the U.S., and CEC Rule 28-200 in Canada. The<br />
<strong>KT7</strong> as a manual motor starter is available in a general purpose enclosure,<br />
water tight enclosure or Type 7/9 enclosure. Undervoltage or shunt<br />
trip relays are also available.<br />
Traditional Group <strong>Motor</strong> Applications<br />
UL/CSA<br />
<strong>KT7</strong> <strong>Motor</strong> <strong>Circuit</strong> <strong>Controllers</strong> are also UL/CSA listed as manual starters<br />
for use in Group <strong>Motor</strong> installations. This listing (and application) has<br />
been the most popular in the United States because of the reduced panel<br />
space and cost savings it provides.<br />
NEC article 430-52 states that each motor must have a Branch <strong>Circuit</strong><br />
Protective Device (BCPD) consisting of a fused disconnect, fuse block &<br />
set of fuses, or a circuit breaker. A typical circuit is illustrated in Figure 1.<br />
Figure 1<br />
Classic Group <strong>Motor</strong> <strong>Circuit</strong> (NEC 430-52)<br />
Even though this method is highly effective and widely used, it has<br />
several drawbacks.<br />
• Breakers or fuse blocks for each motor circuit are<br />
expensive<br />
• The panel space required to house many components like this is<br />
substantial<br />
• Installations of this type are labor intensive and therefore<br />
more costly<br />
NEC 430-53 [CEC 28-206] however, provides several exceptions to 430-<br />
52 [CEC 28-204] that allow you to connect a group of motors under<br />
one BCPD. These exceptions can be found under:<br />
• 430-53(a) - For <strong>Motor</strong>s 1 HP or Less<br />
• 430-53(b) - The Smallest <strong>Motor</strong> is Protected<br />
• 430-53(c) - Other Group Installations<br />
For example, Figure 2 illustrates how a circuit would look utilizing provision<br />
(a) or (b) above. What was once three branch circuits, with three<br />
BCPD’s, is now one branch circuit with one BCPD.<br />
Figure 2<br />
NEC Article 430-53 circuitry without <strong>KT7</strong><br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />
Apps.<br />
F82<br />
Discount Schedule A-1
Application Notes<br />
Series <strong>KT7</strong> <strong>Motor</strong> <strong>Circuit</strong> <strong>Controllers</strong><br />
Methods of Applying <strong>KT7</strong> <strong>Motor</strong> <strong>Circuit</strong> <strong>Controllers</strong> (continued)<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />
It appears that the exceptions in 430-53 address the expensive drawbacks<br />
to having one BCPD for each motor. Expensive fuses (or circuit breakers)<br />
have been eliminated. Panel space has been significantly reduced, as well<br />
as, the labor to install the circuit.<br />
Unfortunately, NEC 430-53 (a) or (b) [CEC 28-602 (3)(b)] limits the<br />
group to a few small motors. However, by applying the <strong>KT7</strong> under 430-<br />
53 (c) (Figure 3), the problems associated with 430-53 (a) and (b) are<br />
overcome.<br />
Figure 3<br />
Article 430-53 <strong>Circuit</strong>ry With <strong>KT7</strong><br />
• Only one fuse block (or circuit breaker) is used as the BCPD<br />
• Panel size has been significantly reduced<br />
• Wiring and installation time has been significantly reduced<br />
• We have assured protection against low level faults that the BCPD<br />
would pass<br />
• Larger horsepower motors can be grouped with smaller ones<br />
Group Installation under 430-53(c) requires that the BCPD be calculated<br />
and either supplied within the control panel or, if mounted<br />
externally, the BCPD value must be specified by a label within the panel.<br />
Always refer to the NEC code before applying the <strong>KT7</strong> in Group <strong>Motor</strong><br />
Installations.<br />
As stated earlier, Group Installations are the most popular applications<br />
for KTA <strong>Motor</strong> <strong>Circuit</strong> <strong>Controllers</strong> in North America. They greatly reduce<br />
cost when compared to using fuses or circuit breakers in each motor<br />
branch circuit.<br />
<strong>Motor</strong> Disconnecting Applications - UL/CSA<br />
The new <strong>KT7</strong> <strong>Motor</strong> <strong>Circuit</strong> <strong>Controllers</strong> are also UL/CSA listed as<br />
manual motor controllers with the optional approval “Suitable for use as<br />
a motor disconnect.” This UL Listing (UL508, Part III) is new in 1999<br />
and allows <strong>KT7</strong>s to meet the requirements for applications as “at-motor”<br />
disconnects. All manual starters used in such applications must be<br />
marked as “Suitable for use as a motor disconnect”. The <strong>KT7</strong> can be used<br />
in an enclosure with a lockable handle as a manual motor starter and is<br />
an approved means of motor disconnect.<br />
Under the provisions of UL508 Part III, a <strong>Manual</strong> <strong>Motor</strong> Controller can<br />
be labeled “Suitable for use as motor disconnect” and does not require<br />
compliance with UL 98 Disconnect Rules. The primary difference between<br />
UL98 and UL 508 Part III is that the <strong>Manual</strong> <strong>Motor</strong> Controller must bear<br />
a maximum KAIC rating. This rating must be considered in the application<br />
of <strong>KT7</strong> as a motor disconnect.<br />
Corresponding to this new section of UL, the NEC code Article 430-109<br />
a1b6 [CEC 28-602 (3)(b)] permits the use of a manual motor controller<br />
when installed between the BCPD and the motor.<br />
SeIf-Protected <strong>Manual</strong> Combination Starter<br />
Applications (Type E) - UL/CSA<br />
UL508, Part IV, Sections A–E (17th Edition) cover combination motor<br />
controllers that provide a disconnecting means, a load switching means,<br />
overload and short-circuit protection all incorporated within the same<br />
device or assembly. Under these provisions, the new <strong>KT7</strong> <strong>Motor</strong> <strong>Circuit</strong><br />
<strong>Controllers</strong>, with improved current limiting and breaking capacity<br />
(KAIC rating), are now UL/CSA Listed as self-protected (Construction<br />
Type E) manual combination motor controllers. This Type E rating<br />
eliminates the need for individual branch fuses (per UL 198) or a thermal-magnetic<br />
circuit breaker or magnetic-only circuit breaker (per UL<br />
489) as the Branch <strong>Circuit</strong> Protection Device (BCPD). See Figure 4.<br />
Figure 4<br />
Classic Combo Starter (NEC Article 430-52)<br />
Further, the Type E rating eliminates the need for a disconnecting means<br />
(per UL 98) for enclosed and dead-front switches or UL 1087 molded<br />
case switches or UL 489 molded case circuit breakers.<br />
Corresponding to this UL Type E rating, NEC code (Article 430-52<br />
c6) now allows a self-protected combination controller to be used as the<br />
BCPD instead of the classic devices listed in Table 430-152.<br />
Simply stated this new Type E listing allows the <strong>KT7</strong> <strong>Manual</strong> Combination<br />
<strong>Motor</strong> <strong>Controllers</strong> to be used as short-circuit protection, overload<br />
protection and as the motor disconnect on motor branch circuits. See<br />
Figure 5.<br />
F<br />
<strong>Motor</strong> <strong>Circuit</strong><br />
<strong>Controllers</strong><br />
Apps.<br />
Discount Schedule A-1<br />
F83
Application Notes<br />
Series <strong>KT7</strong> <strong>Motor</strong> <strong>Circuit</strong> <strong>Controllers</strong><br />
Methods of Applying <strong>KT7</strong> <strong>Motor</strong> <strong>Circuit</strong> <strong>Controllers</strong> (continued)<br />
F<br />
<strong>Motor</strong> <strong>Circuit</strong><br />
<strong>Controllers</strong><br />
Apps.<br />
Figure 5<br />
<strong>KT7</strong> <strong>Manual</strong> <strong>Motor</strong> Controller and “At motor” Disconnect<br />
It should be noted that <strong>KT7</strong> <strong>Manual</strong> <strong>Motor</strong> <strong>Circuit</strong> Controller, when listed as<br />
self-protected (Type E) device, is rated for Wye-connected power systems for<br />
voltages above 240 volts (i.e. 480Y / 277 volts common in the United States or<br />
600Y/ 347 volts common in Canada).<br />
Effective July 16, 2001<br />
UL made changes to its specifications for self-protected Type E combination<br />
controllers. Among them is a required increase in space between<br />
line side terminals, which directly affects <strong>KT7</strong> controllers in specific<br />
applications.<br />
<strong>KT7</strong> controllers used as Branch <strong>Circuit</strong> Protection Devices (BCPDs)<br />
in Type E applications will be required to meet the new specifications,<br />
provided they were produced after July 16, 2001. <strong>KT7</strong>s produced prior<br />
to that date (including those currently in inventory) may be sold and<br />
installed without alteration. <strong>KT7</strong> controllers applied as manual motor<br />
starters, or part of a group installation, are exempt from the new requirement,<br />
regardless of production date.<br />
• <strong>KT7</strong> controllers produced prior to July 16, 2001, will be used in CL7,<br />
CK7, enclosed <strong>KT7</strong>, CX7, or any custom control panel without the new<br />
terminal adaptors, as allowed by UL, until inventory is depleted.<br />
• All CL7, CK7, enclosed <strong>KT7</strong> and CX7 starters assembled with new <strong>KT7</strong><br />
controllers (with locking notch) in our Houston or Mississauga facilities<br />
will include the new terminal adaptors. No list price change will be made<br />
to these assemblies.<br />
• When applicable, all assemblies shipped from the factory will be Type E<br />
compliant with the change effective July 16, 2001.<br />
Individual Combination Starter Applications<br />
The next logical step is to combine a CA7 contactor to the new (Type E)<br />
self-protected manual combination <strong>KT7</strong> controller. The <strong>KT7</strong> starter provides<br />
the overload and short circuit protection, as well as, the disconnecting<br />
function for the motor, while the CA7 contactor allows for remote<br />
operation via pushbuttons. By contrast, the traditional fusible combination<br />
starter consists of an L10 fusible disconnect switch, short-circuit<br />
protection (alternately an MCP or MCCB), a contactor for remote<br />
operation and a CEP7 overload relay (see Figure 4). The <strong>KT7</strong> Type E<br />
manual controller + CA7 contactor combination can now be compared<br />
with a traditional fusible or circuit breaker Combination Starter including<br />
the means of disconnect.<br />
<strong>KT7</strong><br />
<strong>Motor</strong> <strong>Circuit</strong><br />
Controller<br />
(disconnect)<br />
CA7<br />
Contactor<br />
Figure 6<br />
Type E Combo <strong>Motor</strong> Controller<br />
(starter) and “At motor” Disconnect<br />
(NEC Article 430-52 (c6)<br />
Multi-motor Starter Combination<br />
Applications<br />
The <strong>KT7</strong> Construction Type E rating also eliminates concern for all of<br />
the NEC 430-53 [CEC 28-206] rules for installations involving multiple<br />
motor starters in a single control panel. The result is maximum flexibility<br />
and minimum panel size without the restrictive and cumbersome rules<br />
involved with typical multi-motor (Group Installation) applications.<br />
This means that the main fuses or circuit breaker are no longer necessary<br />
to meet the requirement of a Group Installation Branch<br />
<strong>Circuit</strong> Protection Device (BCPD). A non-fused disconnect may be<br />
needed to meet the safety disconnect rules for the multi-motor starter<br />
control panel. It is important to separate the code requirements for<br />
BCPD’s from the safety codes requiring a panel disconnect to be “in<br />
sight and within 50 feet” to protect the maintenance electrician. <strong>KT7</strong>s<br />
perform the function of BCPD’s under the Type E combination motor<br />
controller approval and may simply be selected according to the motor<br />
full-load current with consideration for the potential fault-current.<br />
Figure 7<br />
Multi-motor Starter Panel using <strong>KT7</strong> as Type E Combo Starter (B.C.P.D.s)<br />
per NEC Article 430-52 (c6)<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />
F84<br />
Discount Schedule A-1
Application Notes<br />
Series <strong>KT7</strong> <strong>Motor</strong> <strong>Circuit</strong> <strong>Controllers</strong><br />
Methods of Applying <strong>KT7</strong> <strong>Motor</strong> <strong>Circuit</strong> <strong>Controllers</strong> (continued)<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />
Short-circuit Coordination<br />
The concept of Type 1 and Type 2 coordination are European based but<br />
are certainly not new to the North American market. Fuse companies<br />
have been at the forefront of advancing the concepts and advantages of<br />
Type 2 protection. An appreciation for the advancements offered by selfprotected<br />
combination motor controllers like <strong>KT7</strong> must start with a firm<br />
understanding of Type 1 and Type 2 protection versus Construction Type<br />
E standards.<br />
Type 1<br />
• Under short-circuit conditions, the contactor or<br />
starter shall cause no danger to persons or installation.<br />
• Damage to the contactor and the overload relay is acceptable.<br />
• It may not be suitable for further service without repair and<br />
replacement of parts.<br />
A UL listing of a device or combination of devices like a contactor and<br />
an overload relay would be equivalent to Type 1 coordination in European<br />
(IEC) terminology.<br />
Type 2<br />
• Under short-circuit conditions, the contactor or starter shall<br />
cause no danger to persons or installation and shall be suitable<br />
for further use.<br />
• The risk of contact welding is recognized, in which case the<br />
manufacturer shall indicate the measures to be taken in regards<br />
to maintenance of the equipment.<br />
Most of the above is European terminology that has worked its way into<br />
North American terminology.<br />
UL508E is the UL “Outline of Investigation for Type 2 Coordination.”<br />
It is important to note that UL508E is NOT the same as Construction<br />
Type E Self-protected Combination <strong>Motor</strong> <strong>Controllers</strong> (which falls<br />
under the UL508 Safety Standard for Industrial Control in Section 76 as<br />
we have outlined). This means that UL does not give a “Listing” under<br />
UL508E but rather is a performance standard and not a safety issue.<br />
Companies who publish Type 2 coordination application tables in accordance<br />
with investigation procedures outlined in UL508E must be backed<br />
by self certified tests to verify compliance.<br />
Type 1 and Type 2 coordination have historically been applied to the<br />
combination of a circuit breaker or a set of fuses protecting a contactor<br />
(i.e.: CA7) and an overload (i.e.: CEP7 or CT7). If you select a particular<br />
UL approved contactor and UL Approved overload from the standard<br />
selection tables in our catalog then you have Type 1 coordination. Similarly,<br />
when you combine a CA7 contactor with a <strong>KT7</strong> Type E <strong>Manual</strong><br />
Self-protected Combination Controller by selecting from standard<br />
<strong>KT7</strong> selection tables then you may only have Type 1 protection for the<br />
combination. If your customer wants Type 2 protection then we supply<br />
coordination tables. You must go to the Type 2 protection tables in the<br />
technical section of the <strong>KT7</strong> literature to insure Type 2 protection.<br />
Type E<br />
Construction Type E Self-protected Combination <strong>Motor</strong> <strong>Controllers</strong><br />
• Do not require branch circuit short circuit protective device (fuse or<br />
circuit breaker) upstream<br />
• Includes coordinated overload and short circuit protection<br />
• No welding of contacts is allowed<br />
• Incorporates a motor disconnect rating<br />
• Includes an endurance standard after interrupting a short-circuit<br />
exceeding that specified for Type 2 (UL508E).<br />
This means the test for self-protected combination controllers is more<br />
stringent than Type 2; therefore, many people refer to Type E with implication<br />
not only to the construction type as defined under UL508 Part III<br />
Table 76.2 and applied in accordance with NEC 430-52C Option 6 but<br />
also to the type of coordinated short-circuit protection achieved.<br />
Short-circuit coordination is about the level of damage allowed to the<br />
control equipment under a short circuit condition and the speed of<br />
operation is the key to current limitation.<br />
Suitability for Tap Conductor Protection<br />
For several years, the industry has been applying manual motor circuit<br />
controllers in Group Installations under NEC 430-53C. Many of you<br />
have been aware of the vagueness of the current NEC with respect to<br />
NEC 430-53D concerning “Single <strong>Motor</strong> Taps.” The 2002 NEC added<br />
a new provision which clarifies the sizing of wires in a Group Installation<br />
where the wires feeding each motor circuit controller is considered to be<br />
a tap conductor<br />
NEC-430-53-D-1 restricts the wire feeding the motor circuit controller<br />
to be equal to the wire connected to the BCPD which is extremely limiting.<br />
NEC-430-53-D-2 allows reduction of the sizing of the wire leading<br />
to the BCPD to not less than 1/3 of the wire connected to the B.C.P.D.<br />
Since most 25 ampere frame motor circuit controller only allow for #10<br />
wire maximum (which is rated for 40 amperes) per UL508A “Internal<br />
Wiring Standard”; it follows that the B.C.P.D. must be limited to 120<br />
amperes maximum. Note that the actual FLA connected is limited to<br />
80% of the wire rating. It has been the position of many in the industry<br />
since the introduction of motor circuit controllers in the early 1980’s that<br />
NEC 430-53D was never intended to apply to multiple motor starter<br />
control panels per NEC 430-53C part 1&3, but rather to separately<br />
mounted units with wire duct and gutter taps as described in NEC 430-<br />
53C part 2. This claim was largely based on the maximum BCPD rating<br />
given to Group Rated <strong>Controllers</strong> under UL508 which often exceed the<br />
120 ampere wire limits. The 2002 NEC further clarified that wire size inside<br />
the multiple motor starter panel under Group Installation is covered<br />
by the provisions of Single <strong>Motor</strong> Taps under NEC430-53D.<br />
F<br />
<strong>Motor</strong> <strong>Circuit</strong><br />
<strong>Controllers</strong><br />
Apps.<br />
Discount Schedule A-1<br />
F85
Application Notes<br />
Series <strong>KT7</strong> <strong>Motor</strong> <strong>Circuit</strong> <strong>Controllers</strong><br />
F<br />
<strong>Motor</strong> <strong>Circuit</strong><br />
<strong>Controllers</strong><br />
Methods of Applying <strong>KT7</strong> <strong>Motor</strong> <strong>Circuit</strong> <strong>Controllers</strong> (continued)<br />
The 2002 NEC has new provisions for Single <strong>Motor</strong> Taps under Section<br />
430-53D-3, which clearly provides for sizing motor circuit controller<br />
wires at 1/10 if the length does not exceed 10 feet. This means most 25<br />
ampere frame motor circuit controller that only allow for #10 wire maximum<br />
might be as large as 400 amperes. Further that 45 ampere frame<br />
motor circuit controllers that allow for #4 wire maximum (which is rated<br />
for 105 amperes) might be as large as 1050 amperes. It should be noted<br />
that mini-bus bars are often used to inter-connect the line side of motor<br />
circuit controllers may increase the capacity of the allowable wire size.<br />
This change in the 2002 NEC does require some additional testing of the<br />
motor circuit controller under UL508 in order to mark the device “Suitable<br />
for Tap Conductor Protection in a Group Installation.” The testing<br />
associated with single motor taps is nearly as difficult as those associated<br />
with the test for Self-protected Combination <strong>Motor</strong> <strong>Controllers</strong> (described<br />
elsewhere in this white paper). This means that the Tap Conductor<br />
Protection ratings may well align with the ratings for Self-protected<br />
Combination <strong>Motor</strong> <strong>Controllers</strong>.<br />
It is the opinion of this writer that the strict enforcement of the wire sizing<br />
options defined by NEC 430-53D-1, -2, or -3 will force the industry<br />
to apply Self-protected Combination <strong>Motor</strong> <strong>Controllers</strong> (Construction<br />
Type E or Type F) in multiple motor starter panels under the provisions<br />
of NEC 430-52-C- 6 as opposed to applying simple Group Rated<br />
<strong>Manual</strong> <strong>Motor</strong> <strong>Circuit</strong> <strong>Controllers</strong> under Group Installations as defined<br />
under NEC 430-53-C.<br />
Assemblies Using <strong>KT7</strong><br />
Since devices like KTA7 do not include a magnetic coil contactor in the<br />
assembly, they are considered to be manual motor controllers. If you are<br />
building a multi-motor starter panel you probably need to provide for<br />
remote control and so you add a contactor to the assembly. Sprecher +<br />
Schuh has combined the <strong>KT7</strong> Self-protected Combination Controller<br />
(Construction Type E) into assemblies with appropriately sized contactors.<br />
These assemblies are available in three varieties:<br />
• CL4 = <strong>KT7</strong> + Connector + CA4 Mini-contactor<br />
• CL7 = <strong>KT7</strong> + Connector + CA7 Contactor<br />
• CK7 = <strong>KT7</strong> + CA7 mounted on a DIN adapter socket with<br />
terminal blocks<br />
CL4 and CL7 use connectors (i.e: <strong>KT7</strong>-25S-PEC23) to mate the <strong>KT7</strong><br />
with CA4 and CA7 contactors. Sprecher + Schuh is pleased to announce<br />
that we now have cUL Approval of our –PEC and –PNC connectors.<br />
The recognition of these connectors paves the way to testing and approval<br />
of assemblies using <strong>KT7</strong>.<br />
Type E Self-protected Combination <strong>Motor</strong><br />
Controller Assemblies<br />
An assembly of a Construction Type E <strong>KT7</strong> <strong>Manual</strong> Controller plus a<br />
contactor can be tested as a Self-protected Combination Controller. This<br />
means the assembly must meet all of the same rigid standards including<br />
Type E coordination as described above. Sprecher + Schuh provides additional<br />
tables showing the KAIC ratings of CK7 starters already approved<br />
by UL as Type E assemblies as well as the CL4 & CL7 ratings that are<br />
pending UL approval at the time of this printing.<br />
Type F Combination <strong>Motor</strong> <strong>Controllers</strong><br />
Manufacturers of Construction Type E controllers have been working<br />
closely with UL concerning the addition of a Construction Type F Combination<br />
<strong>Motor</strong> Controller to their specifications and test procedures.<br />
Recently UL did add Type F to UL508 Part III Section 76. Construction<br />
Type F is defined as a Type E <strong>Manual</strong> Self-protected Combination<br />
Controller combined with a magnetic contactor but allowing damage to<br />
the contactor under a short circuit. The damage allowed to the contactor<br />
is similar to that allowed to Construction Type A, B, C or D Combination<br />
<strong>Starters</strong>, which are circuit breakers, fused disconnect, magnetic<br />
only circuit breaker or motor circuit protectors (MCP) combined with a<br />
standard contactor and overload relay better known as the classic Combo<br />
<strong>Starters</strong>.<br />
It is important to point out that you start with a UL Approved Type E<br />
<strong>Manual</strong> Self-protected <strong>Motor</strong> controller and the contactor as an assembly<br />
but test to the same standards as Type 1 protection (just as you would<br />
for a Classic Type A-D Combo). UL has chosen to call this new device a<br />
Combination <strong>Motor</strong> Controller which is more exactly defined as Construction<br />
Type F under to UL508 Part III Section 76.<br />
Note that the Type F designation ‘Combination <strong>Motor</strong> Controller’ is<br />
missing the term ‘Self-protected’ which is reserved for an assembly that<br />
is fully Type E Approved as described above. This means that Type E<br />
assemblies are superior to Type F assemblies with respect to coordinated<br />
protection. Both Type F and Type E are valid selections for customers to<br />
make an informed price versus performance choice.<br />
Once again, if the customer wants Type 2 protection, the manufacturer<br />
must back their recommendations with self-certify testing. Sprecher +<br />
Schuh provides additional tables for the customer to select Type 2 KAIC<br />
ratings for Type F Combination <strong>Motor</strong> <strong>Controllers</strong> in the technical<br />
data section of this chapter. It might be said that Construction Type F<br />
Coordination Type 2 ratings are very close to those of Type E. It is important<br />
to note that the difference is that Type E provides the assurance<br />
of an endurance standard after interrupting a short-circuit exceeding that<br />
specified for Type 2 (UL508E).<br />
In short, you could say that Type F1 is good, Type F2 is better and<br />
Type E is the best.<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />
Apps.<br />
F86<br />
Discount Schedule A-1
Application Notes<br />
Series <strong>KT7</strong> <strong>Motor</strong> <strong>Circuit</strong> <strong>Controllers</strong><br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />
Methods of Applying <strong>KT7</strong> <strong>Motor</strong> <strong>Circuit</strong> <strong>Controllers</strong> (continued)<br />
A Note About UL1077 Mini-<strong>Circuit</strong> Breakers<br />
All too often we see UL1077 DIN rail mounted Mini-circuit breakers<br />
applied as branch circuit short-circuit protection ahead of a standard<br />
contactor and overload relay. UL1077 Supplemental <strong>Circuit</strong> Breakers<br />
were never intended to replace UL489 Approved <strong>Circuit</strong> Breakers as<br />
short-circuit protection for a motor branch circuit. It is important for<br />
customers who have been employing the use UL1077 circuit breakers<br />
to “protect” motor circuits that the practice is not approved for this purpose<br />
nor is it in compliance with NEC 430-52. Sprecher + Schuh sells<br />
UL1077 Mini-circuit breakers as well <strong>KT7</strong> <strong>Motor</strong> <strong>Circuit</strong> controllers<br />
and it our desire to help customers apply each in accordance with applicable<br />
codes and standards. Please reference our technical application<br />
notes for the proper application of UL1077 Mini-CBs.<br />
There are UL489 Approved Mini-CBs in the marketplace that can be applied<br />
on 240 volt motor applications in accordance with UL and NEC.<br />
Note that these 240 volt UL489 circuit breakers are often seen improperly<br />
applied to 480 volt applications. This DOES NOT comply with UL<br />
and NEC as would the KTA7 <strong>Motor</strong> <strong>Circuit</strong> Controller, which can be<br />
applied for this purpose in applications up to 600 volts.<br />
It should be noted that UL489 Mini-CB’s do not comply with UL508<br />
as an overload relay. Therefore anyone applying a UL489 Mini-CB must<br />
also add a true overload relay to each motor circuit.<br />
Neither UL1077 or UL489 Mini-CBs have the ability to interrupt a high<br />
ampere short-circuit with the speed of a <strong>KT7</strong> <strong>Motor</strong> <strong>Circuit</strong> Controller,<br />
nor do they have the KAIC withstand rating, the ability to provide Type<br />
2 coordination and certainly not Construction Type E approvals or level<br />
of equipment protection.<br />
For additional information concerning the proper application of UL1077<br />
Mini-CB’s, please refer to our White Paper located in the Mini-CB’s section<br />
of the Sprecher + Schuh catalog.<br />
Summary<br />
<strong>KT7</strong> can be applied as a:<br />
• <strong>Manual</strong> <strong>Motor</strong> Controller<br />
• Group Installation Overload Relay<br />
• <strong>Manual</strong> Self-Protected Combination <strong>Motor</strong> Controller (Type E)<br />
CL4, CL7 and CK7 can be applied as a:<br />
• Self-Protected Combination <strong>Motor</strong> Controller assembly (Type E)<br />
• Combination <strong>Motor</strong> Controller (Type F)<br />
The main fuses or circuit breaker are no longer necessary to meet the<br />
requirement of a Group Installation BCPD. A label within the panel<br />
specifying the BCPD outside the panel is a thing of the past. Multi-motor<br />
starter panels using the new <strong>KT7</strong> verses Sprecher + Schuh’s previous<br />
<strong>Motor</strong> <strong>Circuit</strong> Controller (KTA3) probably won’t look much different.<br />
The real difference is the NEC rules applied to accomplish the task, along<br />
with an increased level of KAIC Type 2 protection against the possibility<br />
of a short-circuit fault.<br />
Applying these state-of-the-art controllers properly in North America<br />
requires a working knowledge of UL, CSA, and NEC. It is our objective<br />
to assist customers in keeping pace with developments that can impact<br />
the cost effective protection of their control systems, reduce downtime<br />
and increase production for their customers. We encourage customers<br />
to contact their local Sprecher + Schuh representative or the factory to<br />
discuss issues about applications of these devices.<br />
F<br />
<strong>Motor</strong> <strong>Circuit</strong><br />
<strong>Controllers</strong><br />
Apps.<br />
Discount Schedule A-1<br />
F87
KTA3-25<br />
(Now obsolete)<br />
Sprecher + Schuh <strong>KT4</strong> has replaced the KTA3-25.<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />
<strong>KT4</strong> <strong>Manual</strong> <strong>Motor</strong> Starter
<strong>KT4</strong> <strong>Manual</strong> <strong>Motor</strong> <strong>Starters</strong><br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />
<strong>Manual</strong> <strong>Motor</strong> Staters – General Description ................................................................................. F90<br />
Quick Selection Guide ................................................................................................................... F91<br />
Accessories .............................................................................................................................F92-95<br />
Contact Blocks ........................................................................................................................ F92<br />
Adaptor Plates ......................................................................................................................... F92<br />
Release Modules ..................................................................................................................... F93<br />
Connecting Modules ................................................................................................................ F93<br />
Mounting ................................................................................................................................ F94<br />
Enclosures .............................................................................................................................. F94<br />
Push Button Sets ..................................................................................................................... F94<br />
Indicator Lights ....................................................................................................................... F94<br />
Bus Bars ................................................................................................................................. F95<br />
Supply Block ........................................................................................................................... F95<br />
Space Cover ............................................................................................................................ F95<br />
Explosion Proof <strong>Manual</strong> Starter Type EV3 ........................................................................................96<br />
Technical Information ...............................................................................................................F97-99<br />
Time Current Curves ................................................................................................................... F100<br />
Diagrams .................................................................................................................................... F101<br />
Dimensions ..........................................................................................................................F102-103<br />
F<br />
<strong>Motor</strong> <strong>Circuit</strong><br />
<strong>Controllers</strong><br />
<strong>KT4</strong><br />
F89
F<br />
<strong>Motor</strong> <strong>Circuit</strong><br />
<strong>Controllers</strong><br />
<strong>KT4</strong><br />
<strong>Manual</strong> <strong>Motor</strong><br />
Starter<br />
Ideal for use as a manual<br />
starter<br />
The <strong>KT4</strong> is a manual motor starter<br />
that employs the features of power<br />
switching, thermal overload protection<br />
and control circuit signaling in<br />
one compact unit. This manual motor<br />
starter has the advantage of a high<br />
speed magnetic trip mechanism which<br />
limits the let-through current under<br />
short-circuit conditions. The <strong>KT4</strong><br />
can be supplied with field installable<br />
shunt trip or an under voltage trip<br />
unit which exceeds the capabilities of<br />
the classic manual motor starter. This<br />
manual motor starter is available in a<br />
variety of enclosures including general<br />
purpose, watertight and explosion<br />
proof (the most compact on the market<br />
today).<br />
<strong>KT4</strong> Reduces panel space<br />
and saves money in Group<br />
<strong>Motor</strong> Installations<br />
The <strong>KT4</strong> can eliminate the need for<br />
larger and more expensive fuse blocks<br />
and fused disconnects, or circuit<br />
breakers. The potential cost savings in<br />
group motor installations according<br />
NEC 430-53c can be as much as 35%<br />
over conventional methods of branch<br />
circuit protection. And, because so<br />
many features are combined into one<br />
small unit, panel space can be slashed<br />
by as much as 60%.<br />
In addition, the <strong>KT4</strong> line offers a wide<br />
application range from 0.1 to 16 FLA<br />
in installations up to 600V. For group<br />
motor applications, the <strong>KT4</strong> series has<br />
a 250A group installation rating, with<br />
a withstand rating as high as 42 KAIC.<br />
Excellent short circuit and<br />
thermal overload protection<br />
In the event of a short-circuit, the<br />
contacts are opened by magnetic, nonadjusting<br />
tripping elements in times<br />
approaching 2/1000 of a second. This<br />
results in the extremely rapid build-up<br />
of an arc voltage which limits the current<br />
of the short-circuit to a very low<br />
level. Because of this superb current<br />
limiting capability the let-through<br />
current is significantly reduced and the<br />
potential for damage is limited.<br />
Because each <strong>KT4</strong> is individually<br />
calibrated at the factory for the smallest<br />
and largest current, very accurate<br />
thermal overload protection is also<br />
obtained. In addition, the <strong>KT4</strong> is a<br />
Class 10 device ... it trips within 10<br />
seconds under a locked rotor condition<br />
(6 x FLA). Every <strong>KT4</strong> <strong>Manual</strong> <strong>Motor</strong><br />
Starter is equipped with automatic<br />
ambient temperature compensation,<br />
which continually adjusts to surrounding<br />
temperatures. As a result, trip<br />
times remain constant and accurate.<br />
Accessories add versatility<br />
Whether in group motor installations<br />
or as a manual motor starter, numerous<br />
field installable accessories are<br />
available to enhance the <strong>KT4</strong>’s performance:<br />
● Auxiliary Contact Blocks<br />
– are available for internal or<br />
external mounting providing<br />
signal switching capability for<br />
control circuits.<br />
● Shunt trip and Undervoltage<br />
Release Modules<br />
– provides the ability to re<br />
motely actuate the <strong>KT4</strong> in<br />
emergency situations or<br />
continuously monitor the line<br />
voltage.<br />
●<br />
Enclosures – are available in<br />
general protection (IP41),<br />
watertight (IP55), as well as<br />
explosion-proof (Type 7/9)<br />
complete with lockable acces<br />
sories.<br />
● Compact Bus Bar System –<br />
reduces the task of line side wiring<br />
in multiple motor starter installations<br />
which reduces the labor cost<br />
of installation.<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />
<strong>KT4</strong><br />
F90
<strong>KT4</strong> <strong>Manual</strong> <strong>Motor</strong> Starter<br />
<strong>KT4</strong> <strong>Manual</strong> <strong>Motor</strong> Starter ➊<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />
Maximum Horsepower ➊➋<br />
Ordering Information ➊<br />
Single Ø ➋<br />
Three Ø<br />
O/L Relay<br />
Ampere<br />
Magnetic<br />
Response<br />
115V 230V 200V 230V 460V 575V Response ➍ Current Catalog Number Price<br />
~ ~ ~ ~ ~ ~ 0.1 - 0.16 1.8 <strong>KT4</strong>-C2A-A16 133<br />
~ ~ ~ ~ ~ ~ 0.16 - 0.25 2.8 <strong>KT4</strong>-C2A-A25 133<br />
~ ~ ~ ~ ~ ~ 0.25 - 0.4 4.4 <strong>KT4</strong>-C2A-A40 133<br />
~ ~ ~ ~ ~ ~ 0.4 - 0.63 6.9 <strong>KT4</strong>-C2A-A63 154<br />
~ ~ ~ ~ 1/2 3/4 0.63 - 1.0 11 <strong>KT4</strong>-C2A-B10 154<br />
~ 1/10 ~ ~ 1 1 1.0 - 1.6 18 <strong>KT4</strong>-C2A-B16 154<br />
1/10 1/6 1/2 3/4 1 1/2 2 1.6 - 2.5 28 <strong>KT4</strong>-C2A-B25 154<br />
1/8 1/3 3/4 1 3 3 2.5 - 4.0 44 <strong>KT4</strong>-C2A-B40 154<br />
1/4 3/4 1 1/2 2 5 5 4.0 - 6.3 69 <strong>KT4</strong>-C2A-B63 154<br />
1/2 1 1/2 2 3 7 1/2 10 6.3 - 10 110 <strong>KT4</strong>-C2A-C10 154<br />
1 2 3 5 10 15 10 - 16 176 <strong>KT4</strong>-C2A-C16 176<br />
Short <strong>Circuit</strong> Ratings ➌<br />
Catalog Number<br />
<strong>Manual</strong> <strong>Motor</strong> Starter / Group Installation Ratings<br />
Short <strong>Circuit</strong> Rating (kA)<br />
Maximum Branch <strong>Circuit</strong><br />
Protection Rating ➎<br />
480V 600V Amperes<br />
<strong>KT4</strong>-C2A-A16 42 42 250<br />
<strong>KT4</strong>-C2A-A25 42 42 250<br />
<strong>KT4</strong>-C2A-A40 42 42 250<br />
<strong>KT4</strong>-C2A-A63 42 42 250<br />
<strong>KT4</strong>-C2A-B10 42 42 250<br />
<strong>KT4</strong>-C2A-B16 42 42 250<br />
<strong>KT4</strong>-C2A-B25 42 10 250<br />
<strong>KT4</strong>-C2A-B40 18 5 250<br />
<strong>KT4</strong>-C2A-B63 18 5 250<br />
<strong>KT4</strong>-C2A-C10 10 5 250<br />
<strong>KT4</strong>-C2A-C16 10 5 250<br />
➊ Horsepower ratings shown are the maximum rating of the switching capacity of<br />
the main contactors. The final selection of the manual starter depends on the<br />
actual motor full load amps and service factor.<br />
Example #1:<br />
For a motor with a service factor of 1.15 or greater, use the motor nameplate full<br />
load amps and choose the motor starter with the appropriate current range.<br />
<strong>Motor</strong> F.L.A. 4.2A<br />
Service Factor x 1.15<br />
Effective Current = 6.3A<br />
Select catalog number <strong>KT4</strong>-C2A-A63<br />
Example #2:<br />
For a motor with a service factor less than 1.15, use the motor nameplate full load<br />
amps times 0.9 and choose the motor starter with the appropriate current range.<br />
<strong>Motor</strong> F.L.A. 4.2A<br />
Service Factor x 1.0<br />
Multiplier x 0.9<br />
Effective Current = 3.78A<br />
Select catalog number <strong>KT4</strong>-C2A-A40<br />
➋ Single phase horsepower ratings are based on wiring the 3 poles of the device in<br />
series.<br />
➌ The <strong>KT4</strong> motor circuit controller is approved for use in group installation according<br />
to NEC 430-53C. Reference Sprecher+Schuh UL file #E54612.<br />
➍ The actual trip current is 120% of the dial setting.<br />
➎ Although UL Testing of <strong>Manual</strong> <strong>Motor</strong> <strong>Starters</strong> allows for Group Installation with<br />
upstream Branch <strong>Circuit</strong> Protection maximum ratings as high as 250 amperes;<br />
it should be noted that NEC 2002 contains new restrictions under NEC 430-53D<br />
“Single <strong>Motor</strong> Taps”. <strong>KT4</strong> should be applied as outlined in NEC 430-53D-1 or 430-<br />
53-D-2 to be in compliance. <strong>KT4</strong> does not qualify as “Tap Conductor Protection” as<br />
required under NEC 430-53-D-3. Please refer to the Application notes located at<br />
the end of the <strong>KT7</strong> section for more details on compliance.<br />
F<br />
<strong>Motor</strong> <strong>Circuit</strong><br />
<strong>Controllers</strong><br />
<strong>KT4</strong><br />
Discount Schedule A-1<br />
F91
Accessories<br />
<strong>KT4</strong> <strong>Manual</strong> <strong>Motor</strong> Starter<br />
F<br />
<strong>Motor</strong> <strong>Circuit</strong><br />
<strong>Controllers</strong><br />
Accessories for <strong>KT4</strong><br />
Accessory Description Wiring Diagram Catalog Number Price<br />
Auxiliary Contact Block (NO)<br />
13<br />
- mounts internally. <strong>KT4</strong>-C-AEA10 15<br />
Auxiliary Contact Block (NO)<br />
- mounts internally, terminal markings<br />
appropriate when also using “PA” type<br />
auxiliary contact.<br />
<strong>KT4</strong>-C-AEA210 15<br />
Auxiliary Contact Block (NC)<br />
11<br />
- mounts internally. <strong>KT4</strong>-C-AEA01<br />
Auxiliary Contact Block (NC)<br />
- mounts internally, terminal markings<br />
appropriate when also using “PA” type<br />
auxiliary contact.<br />
Two pole Auxiliary Contact Block<br />
(NO/NC) - for side mounting. If using<br />
Compact Bus Bar System, choose bus<br />
bar with 54mm spacing<br />
Two pole Auxiliary Contact Block -<br />
(NO/NO) - for side mounting. If using<br />
Compact Bus Bar System, choose bus<br />
bar with 54mm spacing.<br />
Two pole Auxiliary Contact Block<br />
- (NC/NC) - for side mounting. If using<br />
Compact Bus Bar System, choose bus<br />
bar with 54mm spacing.<br />
15<br />
<strong>KT4</strong>-C-AEA201 15<br />
<strong>KT4</strong>-C-ASA11 28<br />
<strong>KT4</strong>-C-ASA20 28<br />
<strong>KT4</strong>-C-ASA02 28<br />
Accessory Description Catalog Number Price<br />
Accessories for <strong>KT4</strong> continued on next page ➟<br />
Adaptor Plate<br />
Provides capability to base mount one <strong>KT4</strong><br />
Locking Fixture<br />
Padlocking attachment for one <strong>KT4</strong>-25. Locks in the OFF position only.<br />
Metal construction. Holds one to three padlocks with 6mm hasps.<br />
14<br />
33<br />
34<br />
12<br />
31<br />
32<br />
13 21<br />
14 22<br />
13 23<br />
14 24<br />
11 21<br />
12 22<br />
<strong>KT4</strong>-C-N12 11<br />
<strong>KT4</strong>-C-M3 11<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />
<strong>KT4</strong><br />
F92<br />
Discount Schedule A-1
Accessories<br />
<strong>KT4</strong> <strong>Manual</strong> <strong>Motor</strong> Starter<br />
Accessories for <strong>KT4</strong> (continued from previous page)<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />
Accessory Description Wiring Diagram<br />
Accessory<br />
Undervoltage Release Module<br />
- mounts on right hand side,<br />
Prevents <strong>KT4</strong> from operating<br />
unless voltage is present.<br />
Shunt Release Module<br />
- mounts on right hand side.<br />
Remotely trips the <strong>KT4</strong> .<br />
Accessories for <strong>KT4</strong> continued on next page ➟<br />
Description<br />
Connecting Module ➋<br />
- Provides a solid “wireless”<br />
connection between a <strong>KT4</strong><br />
<strong>Motor</strong> <strong>Circuit</strong> Controller and all<br />
CA4 contactors.<br />
Connecting Module - Provides<br />
a solid “wireless” connection<br />
between a <strong>KT4</strong> <strong>Motor</strong> <strong>Circuit</strong><br />
Controller and a CA7 contactor.<br />
<br />
<br />
<br />
C1<br />
F1<br />
Q1<br />
<br />
Voltage /<br />
Rated Current<br />
AC Coil Voltage Catalog<br />
50 HZ 60 HZ Number<br />
24V<br />
<strong>KT4</strong>-C-UXK<br />
24V <strong>KT4</strong>-C-UXJ<br />
48V <strong>KT4</strong>-C-UXX<br />
110V 110V <strong>KT4</strong>-C-UXKD<br />
110V 120V <strong>KT4</strong>-C-UXD<br />
220...230V 240V <strong>KT4</strong>-C-UXF<br />
240...260V <strong>KT4</strong>-C-UXA<br />
240V 277V <strong>KT4</strong>-C-UXT<br />
400V 460V <strong>KT4</strong>-C-UXN<br />
415V 480V <strong>KT4</strong>-C-UXB<br />
500V 575V <strong>KT4</strong>-C-UXM<br />
24V<br />
<strong>KT4</strong>-C-SXK<br />
24V <strong>KT4</strong>-C-SXJ<br />
48V <strong>KT4</strong>-C-SXX<br />
110V 110V <strong>KT4</strong>-C-SXKD<br />
110V 120V <strong>KT4</strong>-C-SXD<br />
220...230V 240V <strong>KT4</strong>-C-SXF<br />
240...260V <strong>KT4</strong>-C-SXA<br />
240V 277V <strong>KT4</strong>-C-SXT<br />
400V 460V <strong>KT4</strong>-C-SXN<br />
415V 480V <strong>KT4</strong>-C-SXB<br />
500V 575V <strong>KT4</strong>-C-SXM<br />
Catalog Number<br />
Price<br />
12A KCD4 7<br />
Connects CA7-9…23 20A KT3-NW23 12<br />
<br />
C2<br />
Price<br />
65<br />
65<br />
F<br />
<strong>Motor</strong> <strong>Circuit</strong><br />
<strong>Controllers</strong><br />
<strong>KT4</strong><br />
Discount Schedule A-1<br />
F93
Accessories<br />
<strong>KT4</strong> <strong>Manual</strong> <strong>Motor</strong> Starter<br />
Accessories for <strong>KT4</strong> (continued from previous page)<br />
F<br />
<strong>Motor</strong> <strong>Circuit</strong><br />
<strong>Controllers</strong><br />
<strong>KT4</strong><br />
<strong>KT4</strong>-C-EA55<br />
Accessory Description Enclosure Rating Catalog No. Price<br />
Accessory Description Kit Catalog No.<br />
<strong>KT4</strong>-C-MT55<br />
<strong>KT4</strong>-C-MK55<br />
<strong>KT4</strong>-C-EE55<br />
Enclosures for Surface Mounting -<br />
With knockouts for two type “DL” pilot lights. Includes ground<br />
and neutral terminals.<br />
Enclosure for Flush Mounting - includes protective earth<br />
and neutral wire terminals.<br />
Emergency Stop Kit<br />
Twist-To-Release<br />
IN STOCK<br />
NOW<br />
Emergency Stop Kit<br />
Key Release<br />
Kit<br />
Price<br />
<strong>KT4</strong>-C-MT 30<br />
<strong>KT4</strong>-C-MK 48<br />
General Purpose (IP41)<br />
For Use With<br />
<strong>KT4</strong>-C-EA41<br />
Watertight (IP55) <strong>KT4</strong>-C-EA55 90<br />
General Purpose (IP41) <strong>KT4</strong>-C-EE41 30<br />
Watertight (IP55) <strong>KT4</strong>-C-EE55 35<br />
Accessory Description Voltage / Rated Current Catalog No. Price<br />
Indicator Lights - mounting in upper part of<br />
enclosure. Length of connection leads: 180 mm<br />
includes lamp.<br />
Enclosure Locking Fixture - Holds one to three<br />
padlocks with 6mm hasps.<br />
Enclosure Membrane - Replacement membrane.<br />
Includes 4 mounting screws (membrane only, does<br />
not include mounting frame).<br />
➊ <strong>KT4</strong> <strong>Manual</strong> <strong>Motor</strong> Starter Not Included. Consult a Sprecher + Schuh<br />
representative for an assembly including a <strong>KT4</strong>.<br />
green<br />
red<br />
white<br />
yellow<br />
120V<br />
240V<br />
400V<br />
415V<br />
480V<br />
120V<br />
240V<br />
400V<br />
415V<br />
480V<br />
120V<br />
240V<br />
400V<br />
415V<br />
480V<br />
120V<br />
240V<br />
400V<br />
415V<br />
480V<br />
For use with<br />
<strong>KT4</strong>-C-EA41 enclosures<br />
For use with<br />
<strong>KT4</strong>-C-EA55 and<br />
<strong>KT4</strong>-C-EE55 enclosures<br />
<strong>KT4</strong>-LG120<br />
<strong>KT4</strong>-LG240<br />
<strong>KT4</strong>-LG400<br />
<strong>KT4</strong>-LG415<br />
<strong>KT4</strong>-LG480<br />
<strong>KT4</strong>-LR120<br />
<strong>KT4</strong>-LR240<br />
<strong>KT4</strong>-LR400<br />
<strong>KT4</strong>-LR415<br />
<strong>KT4</strong>-LR480<br />
<strong>KT4</strong>-LW120<br />
<strong>KT4</strong>-LW240<br />
<strong>KT4</strong>-LW400<br />
<strong>KT4</strong>-LW415<br />
<strong>KT4</strong>-LW480<br />
<strong>KT4</strong>-LY120<br />
<strong>KT4</strong>-LY240<br />
<strong>KT4</strong>-LY400<br />
<strong>KT4</strong>-LY415<br />
<strong>KT4</strong>-LY480<br />
Assembled<br />
Cat No. ➊<br />
50<br />
28<br />
<strong>KT4</strong>-C-M3E 11<br />
<strong>KT4</strong>-C-N18 5<br />
Price<br />
<strong>KT4</strong>-C-EA41 <strong>KT4</strong>-C-MT-EA41 85<br />
<strong>KT4</strong>-C-EE41 <strong>KT4</strong>-C-MT-EE41 65<br />
<strong>KT4</strong>-C-EA55 <strong>KT4</strong>-C-MT-EA55 125<br />
<strong>KT4</strong>-C-EE55 <strong>KT4</strong>-C-MT-EE55 70<br />
<strong>KT4</strong>-C-EA41 <strong>KT4</strong>-C-MK-EA41 103<br />
<strong>KT4</strong>-C-EE41 <strong>KT4</strong>-C-MK-EE41 83<br />
<strong>KT4</strong>-C-EA55 <strong>KT4</strong>-C-MK-EA55 143<br />
<strong>KT4</strong>-C-EE55 <strong>KT4</strong>-C-MK-EE55 88<br />
IN STOCK<br />
NOW<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />
F94<br />
Discount Schedule A-1
Accessories<br />
<strong>KT4</strong> <strong>Manual</strong> <strong>Motor</strong> Starter<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />
Compact Bus Bar System for <strong>KT4</strong><br />
Accessory Description Catalog Number Price<br />
Compact Bus Bar - 45mm spacing<br />
- Bus bar with 45mm spacing accepts<br />
<strong>KT4</strong>’s with or without internally<br />
mounted auxiliary or trip signal contact.<br />
Rated to 65A (UL)/63A (IEC).<br />
Connects two <strong>KT4</strong>’s <strong>KT4</strong>-C-W452 27<br />
Connects three <strong>KT4</strong>’s <strong>KT4</strong>-C-W453 31<br />
Connects four <strong>KT4</strong>’s <strong>KT4</strong>-C-W454 35<br />
Connects five <strong>KT4</strong>’s <strong>KT4</strong>-C-W455 39<br />
Compact Bus Bar - 54mm spacing<br />
- Bus bar with 54mm spacing<br />
accepts <strong>KT4</strong>’s with side mounted<br />
auxiliary contact (type PA-11).<br />
Rated to 65A (UL)/63A (IEC).<br />
Connects two <strong>KT4</strong>’s <strong>KT4</strong>-C-W542 27<br />
Connects three <strong>KT4</strong>’s <strong>KT4</strong>-C-W543 31<br />
Connects four <strong>KT4</strong>’s <strong>KT4</strong>-C-W544 35<br />
Connects five <strong>KT4</strong>’s <strong>KT4</strong>-C-W545 39<br />
Supply Block - Provides connection<br />
from bus bar to power.<br />
Blank Space Cover - Covers bus<br />
bar connections where no <strong>KT4</strong> is<br />
mounted.<br />
<strong>KT4</strong>-C-WT 22<br />
<strong>KT4</strong>-C-WS 3<br />
F<br />
<strong>Motor</strong> <strong>Circuit</strong><br />
<strong>Controllers</strong><br />
<strong>KT4</strong><br />
Discount Schedule A-1<br />
F95
<strong>KT4</strong> <strong>Manual</strong> <strong>Motor</strong> Starter<br />
<strong>KT4</strong> Explosion Proof <strong>Manual</strong> Starter - Type “EV3” ➊<br />
F<br />
<strong>Motor</strong> <strong>Circuit</strong><br />
<strong>Controllers</strong><br />
Class I, Division 1 & 2, Group C & D<br />
Class II, Division 1 & 2, Group #, F & G<br />
Class III<br />
NEMA 7CD & 9EFG<br />
<strong>KT4</strong> Modifications (Factory Assembled)<br />
Single Ø<br />
Description Catalog Number Suffix Adder<br />
Auxiliary Contacts<br />
1 NO - Internal -AEA10 15<br />
1 NC - Internal -AEA01 15<br />
Maximum<br />
Horsepower<br />
Three Ø<br />
115V 230V 200V 230V 460V 575V<br />
1/10 1/6 1/2 3/4 1 1/2 2<br />
1 3 3 5 10 15<br />
O/L Relay<br />
Ampere<br />
Range<br />
Magnetic<br />
Response<br />
Current<br />
Ordering<br />
Information<br />
Catalog Number<br />
Price<br />
0.1 - 0.16 1.8 <strong>KT4</strong>-C2A-A16-EV3 425<br />
0.16 - 0.25 2.8 <strong>KT4</strong>-C2A-A25-EV3 425<br />
0.25 - 0.4 4.4 <strong>KT4</strong>-C2A-A40-EV3 450<br />
0.4 - 0.63 6.9 <strong>KT4</strong>-C2A-A63-EV3 450<br />
0.63 - 1.0 11 <strong>KT4</strong>-C2A-B10-EV3 450<br />
1.0 - 1.6 18 <strong>KT4</strong>-C2A-B16-EV3 450<br />
1.6 - 2.5 28 <strong>KT4</strong>-C2A-B25-EV3 450<br />
2.5 - 4.0 44 <strong>KT4</strong>-C2A-B40-EV3 450<br />
4.0 - 6.3 69 <strong>KT4</strong>-C2A-B63-EV3 450<br />
6.3 - 10 110 <strong>KT4</strong>-C2A-C10-EV3 450<br />
10 - 16 176 <strong>KT4</strong>-C2A-C16-EV3 475<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />
<strong>KT4</strong><br />
➊ “Feed Through” type conduit hubs provided as standard.<br />
F96<br />
Discount Schedule A-1
Technical Information<br />
<strong>KT4</strong> <strong>Manual</strong> <strong>Motor</strong> Starter<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />
Technical Information<br />
<strong>KT4</strong>…<br />
Standards Approvals UL 508; CSA22.2; EN/IEC 60947-1/-2/-4/-5-1/<br />
UL, CSA, CE, SEV, Germ. Lloyd, CEBEC, PTB,<br />
DEMKO, SEMKO, SETI, NEMKO, Bureau Veritas,<br />
Lloyd’s Register of Shipping, Maritime Register<br />
of Shipping, RINA, KEMA<br />
Approvals / Markings<br />
CE, cULus Listed<br />
Rated Insulation Voltage<br />
IEC, SEV, VDE0660 [V] 690<br />
UL, CSA [V] 600<br />
Rated Impulse Withstand Voltage<br />
Main circuits<br />
6 kV<br />
Auxiliary circuits<br />
6 kV<br />
Rated Frequency [Hz] 40…60<br />
Rated Operating Current [A] 0.1…16 (11 ranges)<br />
Life<br />
Mechanical [operations] 100,000<br />
<strong>Electric</strong>al [operations] 50,000<br />
Switching Frequency<br />
Max. 30 operating cycles/hour<br />
Ambient Temperature<br />
Storage<br />
-25°C to +80°C<br />
Operation<br />
-25°C to +60°C<br />
Resistance to climatic change<br />
Humid heat<br />
40°C, 92%, 56 days<br />
Alternating climatic conditions<br />
23°C, 83%/40°C, 93%, 56 cycles<br />
Degree of Protection<br />
IP20 (when wired)<br />
Impact Resistance (shock)<br />
50g, 11ms<br />
Vibration Strength<br />
Frequency Range<br />
10…150Hz<br />
In all directions<br />
>7.5g<br />
Overload Protection<br />
Tripping Time Class 10<br />
Phase failure protection<br />
See time/current curve<br />
Temperature Compensation<br />
-20°C… +60°C (70°C=15% current reduction<br />
of upper rated current)<br />
Magnetic Response<br />
11 x Ie max. (fixed setting)<br />
(Ie max. = max value of the setting range)<br />
Total Power dissipation<br />
<strong>Manual</strong> motor starter at rated load [W] 7<br />
Terminal Connections<br />
Type of terminals<br />
Screwdriver Position No. 2/Blade No. 3<br />
1. conductor 1 to 4 mm 2 / 16 to 12 AWG<br />
2. conductor 1 to 4 mm 2 / 16 to 12 AWG<br />
1. conductor 1 to 6 mm 2 / 16 to 12 AWG<br />
2. conductor 1 to 6 mm 2 / 16 to 12 AWG<br />
1. conductor 1.5 to 6 mm 2 / 16 to 12 AWG<br />
2. conductor 1.5 to 6 mm 2 / 16 to 12 AWG<br />
Tightening torque<br />
2 to 2.5 Nm / 18 to 22 fb-in<br />
Mounting Position - <strong>KT4</strong><br />
Weights<br />
Description Catalog Number Weight<br />
<strong>Manual</strong> <strong>Motor</strong> Starter <strong>KT4</strong>-C2A... 290 g<br />
Auxiliary Contact Blocks<br />
for Flush Mounting<br />
<strong>KT4</strong>-C-AEA 12 g<br />
Auxiliary Contact Blocks<br />
for Left-side Mounting<br />
<strong>KT4</strong>-C-ASA 35 g<br />
Undervoltage Release <strong>KT4</strong>-C-UX 104 g<br />
Shunt Release <strong>KT4</strong>-C-SX 100 g<br />
Bus Bar Feeder Terminal <strong>KT4</strong>-C-WT 36 g<br />
<strong>KT4</strong>-C-W452 42 g<br />
<strong>KT4</strong>-C-W453 69 g<br />
<strong>KT4</strong>-C-W454 94 g<br />
Compact Bus Bar<br />
<strong>KT4</strong>-C-W455 119 g<br />
<strong>KT4</strong>-C-W542 45 g<br />
<strong>KT4</strong>-C-W543 76 g<br />
<strong>KT4</strong>-C-W545 104 g<br />
<strong>KT4</strong>-C-W545 135 g<br />
Blank Space Cover <strong>KT4</strong>-C-WS 3.3 g<br />
Emergency-Stop<br />
<strong>KT4</strong>-C-MT g<br />
Push Button<br />
<strong>KT4</strong>-C-MK g<br />
Enclosure for<br />
Surface Mounting<br />
<strong>KT4</strong>-C-EA41 250 g<br />
Enclosure for<br />
Flush Mounting<br />
<strong>KT4</strong>-C-EA55 258 g<br />
Button Membrane<br />
<strong>KT4</strong>-C-EE41 126 g<br />
<strong>KT4</strong>-C-EE55 134 g<br />
Indicator Light <strong>KT4</strong>-L... 10 g<br />
Hut (DIN) rail Adapter<br />
<strong>KT4</strong>-C-N12 16 g<br />
<strong>KT4</strong>-C-M3E 19 g<br />
Locking Arrangement <strong>KT4</strong>-C-M3 11 g<br />
F<br />
<strong>Motor</strong> <strong>Circuit</strong><br />
<strong>Controllers</strong><br />
<strong>KT4</strong><br />
Discount Schedule A-1<br />
F97
Technical Information<br />
<strong>KT4</strong> <strong>Manual</strong> <strong>Motor</strong> Starter<br />
F<br />
<strong>Motor</strong> <strong>Circuit</strong><br />
<strong>Controllers</strong><br />
Technical Information<br />
Specifications of Accessories<br />
<strong>KT4</strong>-C-AEA...<br />
Auxiliary Contact Block for<br />
Flush Mounting<br />
<strong>KT4</strong>-C-ASA...<br />
Auxiliary Contact Block for<br />
Left-side Mounting<br />
Rated Thermal Current I th<br />
at 40°C ambient temperature [A] 6 10<br />
at 60°C ambient temperature [A] 4 6<br />
Contact Class Coordination According to NEMA<br />
(UL/CSA Standards)<br />
[AC] B 600 Standard Pilot Duty B 600 Standard Pilot Duty<br />
[DC] R 300 Light Pilot Duty R 300 Light Pilot Duty<br />
Back-Up Fuses gG, gL [A] 16 16<br />
Rated Supply current [V] 230/240 400/415 500 690 230/240 400/415 500 690<br />
AC-15 [A] 2 1 0.8 0.5 2 1 0.8 0.5<br />
DC-13 [V] 24 48 110 220 24 48 110 220<br />
[A] 2 0.6 0.2 0.1 2 0.6 0.2 0.1<br />
Terminal Parts<br />
Type of terminals<br />
Screwdriver Pozidrive No. 2 / Blade No. 3<br />
1. conductor 0.75 to 2.5 mm2 / 18 to 14 AWG 0.75 to 2.5 mm2 / 18 to 14 AWG<br />
2. conductor 0.75 to 2.5 mm2 / 18 to 14 AWG 0.75 to 2.5 mm2 / 18 to 14 AWG<br />
1. conductor 0.75 to 4 mm2 / 18 to 14 AWG 0.75 to 4 mm2 / 18 to 14 AWG<br />
2. conductor 0.75 to 4 mm2 / 18 to 14 AWG 0.75 to 4 mm2 / 18 to 14 AWG<br />
1. conductor 0.75 to 4 mm2 / 18 to 14 AWG 0.75 to 4 mm2 / 18 to 14 AWG<br />
2. conductor 0.75 to 4 mm2 / 18 to 14 AWG 0.75 to 4 mm2 / 18 to 14 AWG<br />
Tightening torque 1 to 1.5 Nm / 9 to 13 fb-in 1 to 1.5 Nm / 9 to 13 fb-in<br />
<strong>KT4</strong>-C-UX...<br />
Undervoltage Release Unit<br />
for Right-side Mounting<br />
<strong>KT4</strong>-C-SX...<br />
Shunt Release for<br />
Right-side Mounting<br />
<strong>KT4</strong>-C-WT<br />
Supply Block<br />
Actuating Voltage<br />
Pull-in 0.8 to 1.1 x U s<br />
0.7 to 1.1 x U s<br />
Drop-out 0.7 to 0.35 x U s<br />
~<br />
Rated Control Voltage min. 12V 50 Hz, 14V 60 Hz 12V 50 Hz, 14V 60 Hz<br />
max. 600V 50 Hz 600V 50 Hz<br />
On-Time 100 % 100%<br />
Coil Rating Pull-in 8.5 VA, 6 W 8.5 VA, 6 W<br />
Hold 3 VA, 1.2 W 3 VA, 1.2 W<br />
Terminal Parts<br />
Type of terminals<br />
Screwdriver Pozidrive No. 2/Blade No. 3 Pozidrive No. 2/Blade No. 3 Pozidrive No. 2/Blade No. 3<br />
1. conductor 0.75 to 2.5 mm 2 / 18 to 14 AWG 0.75 to 2.5 mm 2 / 18 to 14 AWG 4 to 16 mm 2 / 14 to 6 AWG<br />
2. conductor 0.75 to 2.5 mm 2 / 18 to 14 AWG 0.75 to 2.5 mm 2 / 18 to 14 AWG 4 to 16 mm 2 / 14 to 6 AWG<br />
1. conductor 0.75 to 4 mm 2 / 18 to 14 AWG 0.75 to 4 mm 2 / 18 to 14 AWG 4 to 16 mm 2 / 14 to 6 AWG<br />
2. conductor 0.75 to 4 mm 2 / 18 to 14 AWG 0.75 to 4 mm 2 / 18 to 14 AWG 4 to 16 mm 2 / 14 to 6 AWG<br />
1. conductor 0.75 to 4 mm 2 / 18 to 14 AWG 0.75 to 4 mm 2 / 18 to 14 AWG 4 to 16 mm 2 / 14 to 6 AWG<br />
2. conductor 0.75 to 4 mm 2 / 18 to 14 AWG 0.75 to 4 mm 2 / 18 to 14 AWG 4 to 16 mm 2 / 14 to 6 AWG<br />
Tightening torque 1 to 1.5 Nm / 9 to 13 fb-in 1 to 1.5 Nm / 9 to 13 fb-in 4 Nm / 36 fb-in<br />
<strong>KT4</strong>-C-W45...<br />
Compact Bus Bar<br />
<strong>KT4</strong>-C-W54...<br />
Compact Bus Bar<br />
Rated Insulation Voltage U i<br />
[V] 690 690<br />
Rated Thermal Current I th<br />
[A} 63 63<br />
<strong>KT4</strong>-C-EA41 / -EE41<br />
Enclosure<br />
<strong>KT4</strong>-C-EA55 / -EE55<br />
Enclosure<br />
<strong>KT4</strong>-C-L...<br />
Indicator Light<br />
IP Protection IP41 IP55 (with seal and protective membrane) IP54<br />
Ambient Temperature [°C] - 25...+ 40 - 25...+ 40 ~<br />
Rated Operating Voltage [V] ~ ~ 120, 240, 415, 480<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />
<strong>KT4</strong><br />
F98<br />
Discount Schedule A-1
Technical Information<br />
<strong>KT4</strong> <strong>Manual</strong> <strong>Motor</strong> Starter<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />
IEC Performance Data (<strong>KT4</strong>-C2A)<br />
-A16 -A25 -A40 -A63 -B10 -B16 -B25 -B40 -B63 -C10 -C16<br />
Switching of standard three phase motors<br />
AC-2, AC-3<br />
230/240V [kW] ~ ~ ~ 0.06/0.09 0.12 0.18/0.25 0.37 0.55/0.75 1.1/1.5 2.2 3.0/4.0<br />
400/415V [kW] 0.02 0.06 0.09 0.18/.25 0.25 0.37/0.55 .75 1.1/1.5 2.2 3.0/4.0 5.5/7.5<br />
500V [kW] ~ ~ ~ 0.18 0.25/0.37 0.55/0.75 1.1 1.5/2.2 2.5/3.0 4.0/6.3 7.5/10<br />
690V [kW] ~ ~ ~ 0.25 0.37/0.55 0.75/1.1 1.8 2.2/3.0 ~ ~ ~<br />
Back-up fuses<br />
gG, aM, only if Icc > Icu<br />
230/240V [A]<br />
~ ~ ~ ~ 50<br />
400/415V [A] ~ ~ ~ 63 50<br />
No Fuses Required<br />
500V [A] ~ ~ 63 50 50<br />
690V [A] 25 35 ~ ~ ~<br />
Ultimate short-circuit breaking capacity Icu<br />
230/240V [kA] 65 65 65 65 65 65 50 50 50 50 3<br />
400/415V [kA] 65 65 65 65 65 65 50 10 10 8 6<br />
500V [kA] 50 50 50 50 50 50 50 3 10 4.5 4.5<br />
690V [kA] 50 50 50 50 50 50 4.5 2 ~ ~ ~<br />
CSA Performance Data (<strong>KT4</strong>-C2A)<br />
-A16 -A25 -A40 -A63 -B10 -B16 -B25 -B40 -B63 -C10 -C16<br />
Maximum short-circuit current<br />
480V [kA] 42 42 42 42 42 42 42 18 18 10 5<br />
600V [kA] 42 42 42 42 42 42 10 5 5 5 5<br />
<strong>Motor</strong> load<br />
1-phase<br />
115V [HP] ~ ~ ~ ~ ~ ~ 1/10 1/8 1/4 1/2 1<br />
230V [HP] ~ ~ ~ ~ ~ 1/10 1/6 1/3 3/4 1 1/2 3<br />
3-phase<br />
200V [HP] ~ ~ ~ ~ ~ ~ 1/2 3/4 1 1/2 2 3<br />
230V [HP] ~ ~ ~ ~ ~ ~ 3/4 1 2 3 5<br />
460V [HP] ~ ~ ~ ~ 1/2 1 1 1/2 3 5 7 1/2 10<br />
575V [HP] ~ ~ ~ ~ 3/4 1 2 3 5 10 15<br />
Auxiliary Contact & Trip Indicator Contact Development<br />
Contact Open<br />
Contact Closed<br />
Auxiliary Contacts<br />
<strong>KT4</strong>-C-ASA (NO)<br />
<strong>KT4</strong>-C-ASA (NC)<br />
F<br />
<strong>Motor</strong> <strong>Circuit</strong><br />
<strong>Controllers</strong><br />
<strong>KT4</strong><br />
Discount Schedule A-1<br />
F99
<strong>KT4</strong> <strong>Manual</strong> <strong>Motor</strong> <strong>Starters</strong><br />
F<br />
<strong>Motor</strong> <strong>Circuit</strong><br />
<strong>Controllers</strong><br />
<strong>KT4</strong><br />
10000<br />
2 h<br />
1 h<br />
Tripping time t A [s]<br />
1000<br />
100<br />
10<br />
1<br />
0.1<br />
0.01<br />
<strong>KT4</strong>-C2A<br />
Time / current characteristics<br />
asymmetrical<br />
symmetrical<br />
Specified limits in compliance<br />
with IEC 60947-4-1 from the<br />
warm state<br />
0.001<br />
0.1 1 10 100<br />
Multiple of the set current I eF<br />
Dispersion: t A ±20%, I eF ±10%<br />
1)<br />
Mean value from<br />
the cold state<br />
2)<br />
The <strong>KT4</strong>-C2A manual motor starter limits short-circuit current I cc<br />
(prospective shortcircuit<br />
current). I D<br />
is the maximum cut-off current (highest instantaneous value of the<br />
limited short-circuit current). This value is indicated in the following diagram as a<br />
function of the system short-circuit current.<br />
Correspondingly the maximum forward j 2 dt energy is limited. This value is indicated in<br />
the following diagram as a function of the system short-circuited current.<br />
<strong>KT4</strong>-C2A<br />
1) Operating Current of Thermal Releases:<br />
The adjustable inverse bimetal trip reliability protects motors against overloads. The<br />
curve shows the mean operating current at an ambient temperature of 20°C<br />
starting from cold.<br />
In equipment at operating temperature, release time is less than or equal to release<br />
time from the cold state.<br />
2) Operating Current of Magnetic Releases:<br />
Electromagnetic instantaneous releases react at a fixed tripping current.<br />
At the upper thermal release setting, this tripping current is 11 times the set cur<br />
rent.<br />
Current To Be Set:<br />
Thermal releases meet the requirements for a thermal release of a starter in accordance<br />
with IEC 60947-4-1 f. If a different value is specified (such as reduced I e<br />
in motors with an ambient temperature higher than 40°C or a site altitude >2000 m<br />
above sea level), the rated operating current I e<br />
must be adjusted.<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />
F100<br />
Discount Schedule A-1
<strong>KT4</strong> Wiring Diagrams<br />
<strong>KT4</strong> <strong>Manual</strong> <strong>Motor</strong> Starter<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />
Single, Two and Three Phase Connection Diagram<br />
F<br />
<strong>Motor</strong> <strong>Circuit</strong><br />
<strong>Controllers</strong><br />
<strong>KT4</strong><br />
Discount Schedule A-1<br />
F101
<strong>KT4</strong> Dimensions<br />
<strong>KT4</strong> <strong>Manual</strong> <strong>Motor</strong> Starter<br />
Dimensions in millimeters except where noted<br />
F<br />
<strong>Motor</strong> <strong>Circuit</strong><br />
<strong>Controllers</strong><br />
1) DIN rail (EN 50022-35)<br />
2) <strong>KT4</strong> w/<strong>KT4</strong>-C-AEA<br />
3) <strong>KT4</strong>-C-ASA<br />
4) <strong>KT4</strong>-C-SXB or <strong>KT4</strong>-C-UXA<br />
<strong>KT4</strong> <strong>Motor</strong> <strong>Circuit</strong> Controller<br />
<strong>KT4</strong>-C-WT<br />
<strong>KT4</strong>-C-N12<br />
<strong>KT4</strong> with Compact Bus Bar<br />
<strong>KT4</strong>-C2A with <strong>KT4</strong>-C-WT<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />
<strong>KT4</strong><br />
F102<br />
Discount Schedule A-1
Dimensions<br />
<strong>KT4</strong> <strong>Manual</strong> <strong>Motor</strong> Starter<br />
Dimensions in millimeters except where noted<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />
<strong>KT4</strong>-C-EA55 Enclosure<br />
<strong>KT4</strong> Explosion Proof Starter - Type “EV3”<br />
<strong>KT4</strong>-C-EE41 Enclosure<br />
F<br />
<strong>Motor</strong> <strong>Circuit</strong><br />
<strong>Controllers</strong><br />
<strong>KT4</strong><br />
Discount Schedule A-1<br />
F103
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />
<strong>Circuit</strong> Protection<br />
Sprecher+Schuh L8 Supplementary Protectors – General Description ............ M2<br />
Series L8 Supplementary Protectors – Trip curve “B” ............................................ M4<br />
Series L8 Supplementary Protectors – Trip curve “C” ............................................ M6<br />
Series L8 Supplementary Protectors – Trip curve “D” ............................................ M8<br />
Accessories .................................................................................................... M10<br />
Technical Information ...................................................................................... M12<br />
Dimensions ..................................................................................................... M17<br />
Sprecher+Schuh L9 Miniature <strong>Circuit</strong> Breakers – General Description .......... M18<br />
Series L9 UL489 <strong>Circuit</strong> Breakers – Trip curve “C” .............................................. M20<br />
Series L9 UL489 <strong>Circuit</strong> Breakers – Trip curve “D” .............................................. M21<br />
Accessories .................................................................................................... M22<br />
Technical Information ...................................................................................... M23<br />
Dimensions ..................................................................................................... M24<br />
<strong>Circuit</strong> Protection Methods ............................................................................... M25<br />
Applying L8 Supplementary Protectors with UL and NEC Guidelines ................ M26<br />
Applying L9 Miniature <strong>Circuit</strong> Breakers with UL and NEC Guidelines ................ M28<br />
Defining <strong>Electric</strong>al Standards .......................................................................... M31<br />
Sprecher + Schuh DIN-rail Mounted Fuse Holders – General Description .... M33<br />
Series FH7 Fuse Holders – Midget Fuses ............................................................ M34<br />
Series FH7 Fuse Holders – Class CC Fuses ......................................................... M35<br />
Series FH7 Fuse Holders – Class J Fuses, 30A .................................................... M36<br />
Series FH7 Fuse Holders – Class J Fuses, 60A .................................................... M37<br />
Fuse Block Selection Guide ............................................................................. M38<br />
M<br />
<strong>Circuit</strong><br />
Protection<br />
M1
M<br />
<strong>Circuit</strong><br />
Protection<br />
Series L8<br />
Supplementary<br />
Protectors<br />
Supplemental short<br />
circuit protection for a<br />
variety of applications<br />
Sprecher+Schuh Series L8 Supplementary<br />
Protectors provide supplemental<br />
overcurrent protection for control<br />
circuits, solenoids, actuators, appliances,<br />
business equipment and a range<br />
of other applications where a high<br />
performance current limiting device is<br />
required. Advanced features and global<br />
approvals make them ideal for use in<br />
equipment installed throughout the<br />
world.<br />
Broad product range<br />
Series L8 Supplementary Protectors are<br />
available in up to 20 different current<br />
ratings from 0.5A to 63A, in one, two<br />
and three pole configurations. Over<br />
180 base models are available with a<br />
full compliment of accessories.<br />
Devices can be used in applications up<br />
to 480V AC and 48V DC with interrupting<br />
capacities up to 10kA.<br />
Safety features provide<br />
enhanced protection<br />
The terminals of Series L8 Supplementary<br />
Protectors provide IP20<br />
protection to guard against accidental<br />
contact with live parts.<br />
To aid troubleshooting, a color-coded<br />
indicator provides positive visual indication<br />
of the device status (green for<br />
OFF, red for ON) and isolation function.<br />
Sprecher+Schuh Supplementary<br />
Protectors also incorporate a trip-free<br />
mechanism - ensuring that the device<br />
operation cannot be defeated by holding<br />
the operator in the ON position.<br />
Easy installation<br />
Sprecher+Schuh Supplementary Protectors<br />
mount on a standard 35mm<br />
DIN-rail. Wire terminals accept<br />
multiple conductors, and bus bars can<br />
be used to quickly distribute power<br />
to many Supplementary Protectors<br />
simultaneously. In addition, power to<br />
the circuit breakers can be fed from<br />
the line or load side.<br />
Global approvals for worldwide<br />
acceptance<br />
Series L8 Supplementary Protectors<br />
are UL Recognized for use in<br />
the United States in accordance with<br />
NFPA 79 (NEC, National <strong>Electric</strong>al<br />
Code). The devices comply with UL<br />
1077 and CSA 22.2 No.235, meeting<br />
the requirements for supplementary<br />
protectors intended for use as overcurrent<br />
protection where branch circuit<br />
protection is not required, or is provided<br />
by another device such as a fuse<br />
or molded case circuit breaker. These<br />
Supplementary Protectors also comply<br />
with IEC 60898 for use in commercial<br />
and residential applications and are CE<br />
marked.<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />
L8<br />
17.5mm 35mm 52.5mm<br />
(≈11/16˝) (≈1-3/8˝) (≈2-1/8˝)<br />
One Pole Two Pole Three Pole<br />
M2
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />
Three trip characteristics<br />
All Sprecher+Schuh L8 Supplementary<br />
Protectors are available with three<br />
different tripping characteristics, Type<br />
“B”, “C”, and “D”. The tripping characteristic<br />
defines the device’s speed of<br />
response (trip-time) to various levels of<br />
overcurrent. Figure 1 shows trip-time<br />
versus overcurrent for Type B, C, and<br />
D devices. The time-current characteristics<br />
enable the device to be optimally<br />
matched to the application. For<br />
example, PLC outputs that can only<br />
tolerate minimal overcurrents are best<br />
protected by Supplementary Protectors<br />
with Type B trip characteristics.<br />
Sprecher+Schuh L8 Supplementary<br />
Protectors are also current limiting<br />
- interrupting fault currents within one<br />
half cycle. Current limiting devices<br />
protect circuit components from damage<br />
by reducing the peak let-through<br />
current which causes damaging<br />
magnetic forces and let-through energy<br />
which generates heat.<br />
Compare these advanced features<br />
Box lug terminals accept #18…#4<br />
(1.0…25mm 2 ) wire as standard<br />
Current limiting and interrupting capacity up<br />
to 5kA at 480VAC.<br />
Trip-free mechanism; device operation<br />
cannot be defeated by holding the operator<br />
in the ON position<br />
Color coded indicator provides visual<br />
indication of the device status and isolation<br />
function<br />
Available in one, two and three pole;<br />
one pole + neutral and three pole + neutral<br />
t [sec] t [min]<br />
120<br />
60<br />
20<br />
10<br />
5<br />
2<br />
1<br />
30<br />
10<br />
5<br />
2<br />
1<br />
0.5<br />
0.2<br />
0.1<br />
0.05<br />
0.02<br />
0.01<br />
0.005<br />
0.002<br />
0.001<br />
0.0005<br />
(Curves at 30° C)<br />
1 2 3 4 5 6 7 8 9 10 15 20 30 40 50<br />
I / I N<br />
Figure 1<br />
Sprecher+Schuh Series L8<br />
Supplementary Protector<br />
Trip Characteristics<br />
Type “B” Characteristic<br />
Developed primarily to protect conductors<br />
and low level signal devices such as PLCs.<br />
Instantaneous trip is three to five times<br />
the rated current of the Supplementary<br />
Protector (3~5 x I n ). The fast trip time of<br />
these devices minimizes damage to control<br />
circuit conductors from low-level faults.<br />
Type “C” Characteristic<br />
Developed primarily for applications with<br />
moderate inrush currents such as lighting,<br />
control circuits and coils, computers and<br />
appliances. Instantaneous trip is five to<br />
ten times the rated current of the Supplementary<br />
Protector (5~10 x I n ). The<br />
higher instantaneous trip level prevents<br />
nuisance tripping, and components being<br />
protected can typically withstand higher<br />
fault currents without being damaged.<br />
Type “D” Characteristic<br />
Developed primarily for applications with<br />
high inrush currents, i.e., transformers,<br />
power supplies and heaters. Instantaneous<br />
trip is ten to twenty times the rated current<br />
of the Supplementary Protector<br />
(10~20 x I n ). The high instantaneous<br />
trip level prevents nuisance tripping, and<br />
components being protected can typically<br />
withstand higher fault currents without<br />
being damaged.<br />
Line and load side terminals accept bus bar<br />
connections for reduced costs and more<br />
efficient installation of multiple devices.<br />
Guarded posidrive terminal screws with<br />
finger-safe protection to IEC 947-1<br />
Devices install on standard 35mm DIN-rail<br />
(EN 50022)<br />
Magnetic trip elements provide Type B,<br />
C and D trip characteristics (IEC and EN<br />
60898), while bimetallic elements protect<br />
against slight overloads.<br />
Amp rating and trip curve characteristic<br />
clearly marked on the device for easy<br />
identification<br />
M<br />
<strong>Circuit</strong><br />
Protection<br />
L8<br />
M3
L8 Supplementary Protectors<br />
Trip Characteristic B<br />
M<br />
<strong>Circuit</strong><br />
Protection<br />
Trip Characteristic B (3~5 x I N ) – Resistive or slightly inductive loads<br />
Rated<br />
Current<br />
(A)<br />
Catalog Number<br />
1 Pole 2 Pole 3 Pole<br />
Price<br />
Std.<br />
Pkg. Catalog Number Price<br />
Std.<br />
Pkg. Catalog Number Price<br />
1 L8-1/1/B 36 12 L8-1/2/B 78 6 L8-1/3/B 118 4<br />
2 L8-2/1/B 36 12 L8-2/2/B 78 6 L8-2/3/B 118 4<br />
3 L8-3/1/B 36 12 L8-3/2/B 78 6 L8-3/3/B 118 4<br />
4 L8-4/1/B 36 12 L8-4/2/B 78 6 L8-4/3/B 118 4<br />
5 L8-5/1/B 36 12 L8-5/2/B 78 6 L8-5/3/B 118 4<br />
6 L8-6/1/B 36 12 L8-6/2/B 78 6 L8-6/3/B 118 4<br />
7 L8-7/1/B 36 12 L8-7/2/B 78 6 L8-7/3/B 118 4<br />
8 L8-8/1/B 36 12 L8-8/2/B 78 6 L8-8/3/B 118 4<br />
10 L8-10/1/B 36 12 L8-10/2/B 78 6 L8-10/3/B 118 4<br />
13 L8-13/1/B 36 12 L8-13/2/B 78 6 L8-13/3/B 118 4<br />
15 L8-15/1/B 36 12 L8-15/2/B 78 6 L8-15/3/B 118 4<br />
16 L8-16/1/B 36 12 L8-16/2/B 78 6 L8-16/3/B 118 4<br />
20 L8-20/1/B 38 12 L8-20/2/B 86 6 L8-20/3/B 130 4<br />
25 L8-25/1/B 38 12 L8-25/2/B 88 6 L8-25/3/B 132 4<br />
30 L8-30/1/B 38 12 L8-30/2/B 88 6 L8-30/3/B 132 4<br />
32 L8-32/1/B 40 12 L8-32/2/B 94 6 L8-32/3/B 142 4<br />
40 L8-40/1/B 42 12 L8-40/2/B 98 6 L8-40/3/B 148 4<br />
50 L8-50/1/B 48 12 L8-50/2/B 112 6 L8-50/3/B 170 4<br />
63 L8-63/1/B 56 12 L8-63/2/B 128 6 L8-63/3/B 194 4<br />
Std.<br />
Pkg.<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />
L8<br />
M4<br />
Discount Schedule B-8
L8 Supplementary Protectors<br />
Trip Characteristic B<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />
Trip Characteristic B (3~5 x I N ) – Resistive or slightly inductive loads<br />
Rated<br />
Current<br />
(A)<br />
1 Pole + Neutral 3 Pole + Neutral<br />
Catalog Number<br />
Price<br />
Std.<br />
Pkg. Catalog Number<br />
Price<br />
1 L8-1/1N-2/B 62 6 L8-1/3N/B 142 3<br />
2 L8-2/1N-2/B 62 6 L8-2/3N/B 142 3<br />
4 L8-4/1N-2/B 62 6 L8-4/3N/B 142 3<br />
6 L8-6/1N-2/B 62 6 L8-6/3N/B 142 3<br />
8 L8-8/1N-2/B 62 6 L8-8/3N/B 142 3<br />
10 L8-10/1N-2/B 62 6 L8-10/3N/B 142 3<br />
13 L8-13/1N-2/B 62 6 L8-13/3N/B 142 3<br />
16 L8-16/1N-2/B 62 6 L8-16/3N/B 142 3<br />
20 L8-20/1N-2/B 74 6 L8-20/3N/B 166 3<br />
25 L8-25/1N-2/B 74 6 L8-25/3N/B 166 3<br />
32 L8-32/1N-2/B 74 6 L8-32/3N/B 166 3<br />
40 L8-40/1N-2/B 74 6 L8-40/3N/B 166 3<br />
50 L8-50/1N-2/B 94 8 L8-50/3N/B 216 3<br />
63 L8-63/1N-2/B 102 8 L8-63/3N/B 240 3<br />
All Supplementary Protectors + neutral are special order.<br />
Std.<br />
Pkg.<br />
M<br />
<strong>Circuit</strong><br />
Protection<br />
L8<br />
Discount Schedule B-8<br />
M5
L8 Supplementary Protectors<br />
Trip Characteristic C<br />
M<br />
<strong>Circuit</strong><br />
Protection<br />
Trip Characteristic C (5~10 x I N ) – Inductive loads<br />
Rated<br />
Current<br />
(A)<br />
Catalog Number<br />
1 Pole 2 Pole 3 Pole<br />
Price<br />
Std.<br />
Pkg. Catalog Number<br />
Price<br />
Std.<br />
Pkg. Catalog Number<br />
0.5 L8-.5/1/C 42 12 L8-.5/2/C 96 6 L8-.5/3/C 138 4<br />
1 L8-1/1/C 42 12 L8-1/2/C 96 6 L8-1/3/C 138 4<br />
2 L8-2/1/C 42 12 L8-2/2/C 96 6 L8-2/3/C 138 4<br />
3 L8-3/1/C 42 12 L8-3/2/C 96 6 L8-3/3/C 138 4<br />
4 L8-4/1/C 42 12 L8-4/2/C 96 6 L8-4/3/C 138 4<br />
5 L8-5/1/C 42 12 L8-5/2/C 96 6 L8-5/3/C 138 4<br />
6 L8-6/1/C 42 12 L8-6/2/C 96 6 L8-6/3/C 138 4<br />
7 L8-7/1/C 42 12 L8-7/2/C 96 6 L8-7/3/C 138 4<br />
8 L8-8/1/C 42 12 L8-8/2/C 96 6 L8-8/3/C 138 4<br />
10 L8-10/1/C 42 12 L8-10/2/C 96 6 L8-10/3/C 138 4<br />
13 L8-13/1/C 42 12 L8-13/2/C 96 6 L8-13/3/C 138 4<br />
15 L8-15/1/C 42 12 L8-15/2/C 96 6 L8-15/3/C 138 4<br />
16 L8-16/1/C 42 12 L8-16/2/C 96 6 L8-16/3/C 138 4<br />
20 L8-20/1/C 42 12 L8-20/2/C 96 6 L8-20/3/C 138 4<br />
25 L8-25/1/C 46 12 L8-25/2/C 106 6 L8-25/3/C 156 4<br />
30 L8-30/1/C 46 12 L8-30/2/C 106 6 L8-30/3/C 156 4<br />
32 L8-32/1/C 48 12 L8-32/2/C 106 6 L8-32/3/C 158 4<br />
40 L8-40/1/C 52 12 L8-40/2/C 116 6 L8-40/3/C 174 4<br />
50 L8-50/1/C 60 12 L8-50/2/C 136 6 L8-50/3/C 200 4<br />
63 L8-63/1/C 68 12 L8-63/2/C 152 6 L8-63/3/C 228 4<br />
Price<br />
Std.<br />
Pkg.<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />
L8<br />
M6<br />
Discount Schedule B-8
L8 Supplementary Protectors<br />
Trip Characteristic C<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />
Trip Characteristic C (5~10 x I N ) – Inductive loads<br />
Rated<br />
Current<br />
(A)<br />
Catalog Number<br />
1 Pole + Neutral 3 Pole + Neutral<br />
Price<br />
Std.<br />
Pkg. Catalog Number<br />
Price<br />
1 L8-1/1N-2/C 84 6 L8-1/3N/C 200 3<br />
2 L8-2/1N-2/C 84 6 L8-2/3N/C 200 3<br />
4 L8-4/1N-2/C 84 6 L8-4/3N/C 200 3<br />
5 L8-5/1N-2/C 84 6 Not Available ~ ~<br />
6 L8-6/1N-2/C 84 6 L8-6/3N/C 200 3<br />
8 L8-8/1N-2/C 84 6 L8-8/3N/C 200 3<br />
10 L8-10/1N-2/C 84 6 L8-10/3N/C 200 3<br />
13 L8-13/1N-2/C 84 6 L8-13/3N/C 200 3<br />
16 L8-16/1N-2/C 84 6 L8-16/3N/C 200 3<br />
20 L8-20/1N-2/C 84 6 L8-20/3N/C 200 3<br />
25 L8-25/1N-2/C 90 6 L8-25/3N/C 210 3<br />
32 L8-32/1N-2/C 92 6 L8-32/3N/C 212 3<br />
40 L8-40/1N-2/C 96 6 L8-40/3N/C 228 3<br />
50 L8-50/1N-2/C 122 8 L8-50/3N/C 276 3<br />
63 L8-63/1N-2/C 130 8 L8-63/3N/C 304 3<br />
All Supplementary Protectors + neutral are special order.<br />
Std.<br />
Pkg.<br />
M<br />
<strong>Circuit</strong><br />
Protection<br />
L8<br />
Discount Schedule B-8<br />
M7
L8 Supplementary Protectors<br />
Trip Characteristic D<br />
M<br />
<strong>Circuit</strong><br />
Protection<br />
Trip Characteristic D (10~20 x I N ) – Highly inductive loads<br />
Rated<br />
Current<br />
(A)<br />
Catalog Number<br />
1 Pole 2 Pole 3 Pole<br />
Price<br />
Std.<br />
Pkg. Catalog Number<br />
Price<br />
Std.<br />
Pkg. Catalog Number<br />
0.5 L8-.5/1/D 42 12 L8-.5/2/D 96 6 Not Available ~ ~<br />
1 L8-1/1/D 42 12 L8-1/2/D 96 6 L8-1/3/D 138 4<br />
2 L8-2/1/D 42 12 L8-2/2/D 96 6 L8-2/3/D 138 4<br />
3 L8-3/1/D 42 12 L8-3/2/D 96 6 L8-3/3/D 138 4<br />
4 L8-4/1/D 42 12 L8-4/2/D 96 6 L8-4/3/D 138 4<br />
5 L8-5/1/D 42 12 L8-5/2/D 96 6 L8-5/3/D 138 4<br />
6 L8-6/1/D 42 12 L8-6/2/D 96 6 L8-6/3/D 138 4<br />
7 L8-7/1/D 42 12 L8-7/2/D 96 6 L8-7/3/D 138 4<br />
8 L8-8/1/D 42 12 L8-8/2/D 96 6 L8-8/3/D 138 4<br />
10 L8-10/1/D 42 12 L8-10/2/D 96 6 L8-10/3/D 138 4<br />
13 L8-13/1/D 42 12 L8-13/2/D 96 6 L8-13/3/D 138 4<br />
15 L8-15/1/D 42 12 L8-15/2/D 96 6 L8-15/3/D 138 4<br />
16 L8-16/1/D 42 12 L8-16/2/D 96 6 L8-16/3/D 138 4<br />
20 L8-20/1/D 42 12 L8-20/2/D 96 6 L8-20/3/D 138 4<br />
25 L8-25/1/D 46 12 L8-25/2/D 106 6 L8-25/3/D 156 4<br />
30 L8-30/1/D 46 12 L8-30/2/D 106 6 L8-30/3/D 156 4<br />
32 L8-32/1/D 48 12 L8-32/2/D 106 6 L8-32/3/D 158 4<br />
40 L8-40/1/D 52 12 L8-40/2/D 116 6 L8-40/3/D 174 4<br />
Price<br />
Std.<br />
Pkg.<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />
L8<br />
M8<br />
Discount Schedule B-8
L8 Supplementary Protectors<br />
Trip Characteristic D<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />
Trip Characteristic D (10~20 x I N ) – Highly inductive loads<br />
Rated<br />
Current<br />
(A)<br />
Catalog Number<br />
1 Pole + Neutral 3 Pole + Neutral<br />
Price<br />
Std.<br />
Pkg. Catalog Number<br />
Price<br />
1 L8-1/1N-2/D 84 6 L8-1/3N/D 200 3<br />
2 L8-2/1N-2/D 84 6 L8-2/3N/D 200 3<br />
4 L8-4/1N-2/D 84 6 L8-4/3N/D 200 3<br />
6 L8-6/1N-2/D 84 6 L8-6/3N/D 200 3<br />
8 L8-8/1N-2/D 84 6 L8-8/3N/D 200 3<br />
10 L8-10/1N-2/D 84 6 L8-10/3N/D 200 3<br />
13 L8-13/1N-2/D 84 6 L8-13/3N/D 200 3<br />
16 L8-16/1N-2/D 84 6 L8-16/3N/D 200 3<br />
20 L8-20/1N-2/D 84 6 L8-20/3N/D 200 3<br />
25 L8-25/1N-2/D 90 6 L8-25/3N/D 210 3<br />
32 L8-32/1N-2/D 92 6 L8-32/3N/D 212 3<br />
40 L8-40/1N-2/D 96 6 L8-40/3N/D 228 3<br />
All Supplementary Protectors + neutral are special order.<br />
Std.<br />
Pkg.<br />
M<br />
<strong>Circuit</strong><br />
Protection<br />
L8<br />
Discount Schedule B-8<br />
M9
Accessories<br />
Series L8 Supplementary Protectors<br />
Accessories<br />
M<br />
<strong>Circuit</strong><br />
Protection<br />
Module<br />
Description<br />
Selectable Two Pole Auxiliary Contact or<br />
Auxiliary / Signal Alarm Module –<br />
• Small set-screw alternates between<br />
operational modes<br />
• Two Form C (two changeover contacts)<br />
• Installs on left side of L8<br />
• Auxiliary contact switches when L8 is<br />
operated manually or tripped electrically<br />
• Signal Alarm contact switches only when<br />
L8 is tripped electrically<br />
Shunt Trip –<br />
• Remotely trips the device<br />
• Installs on left side of L8<br />
Undervoltage Release –<br />
• Prevents device from operating unless<br />
voltage is present<br />
• Installs on left side of L8<br />
• Test button<br />
For use<br />
with…<br />
All L8s<br />
& Shunt<br />
Trip<br />
All L8s<br />
12…110VAC<br />
110…415VAC<br />
All L8s<br />
115 VAC<br />
230 VAC<br />
Connection<br />
Diagrams Catalog Number Price<br />
Two pole auxiliary mode<br />
Auxiliary / Signal alarm mode<br />
LX-AHS3 71<br />
Z8-ASA24<br />
Z8-ASA230<br />
Z8-USA115<br />
Z8-USA230<br />
Allowable Combinations of Field Installed Modules<br />
(1) Auxiliary Contact Module<br />
(1) Selectable Two Pole Auxiliary Contact Module / Auxiliary & Signal Alarm<br />
Contact Module<br />
(1) Shunt Trip Module<br />
(1) Undervoltage Release Module<br />
(1) Auxiliary Contact Module + (1) Shunt Trip Module<br />
All modules install on the left side of the L8.<br />
186<br />
186<br />
292<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />
L8<br />
M10<br />
Discount Schedule B-8
Accessories<br />
Series L8 Supplementary Protectors<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />
Accessories<br />
Accessory Description For use with… Catalog Number Price<br />
Bus Bar – ➊<br />
• Connects one, two and three pole L8s<br />
• Connects one pole + neutral and three<br />
pole + neutral MCBs<br />
• Rated to 80A<br />
• Available in 1 meter lengths<br />
• IEC rated only<br />
End Caps – ➋<br />
• Covers end of Bus Bar to provide touch<br />
safe protection (minimum order quantity<br />
10)<br />
Padlock Hasp –<br />
• Fits securely over switch handle. Prevents<br />
unauthorized activation of L8 during<br />
maintenance<br />
• Provision for one padlock<br />
DIN-rail - 2 meter lengths (6' 6")<br />
All L8 one pole devices<br />
All L8 two pole devices &<br />
one pole + neutral<br />
All L8 three pole devices<br />
All L8 three pole +<br />
neutral devices<br />
Fits ZV7-16-1P+N-2TE &<br />
ZV7-16-3P-3TE<br />
Fits ZV7-16-3P+N-4TE<br />
ZV7-16-1P-1TE<br />
ZV7-16-1P+N-2TE<br />
ZV7-16-3P-3TE<br />
ZV7-16-3P+N-4TE<br />
ZV7-16-AK/2+3P<br />
ZV7-16-AK/4P<br />
51<br />
140<br />
176<br />
238<br />
All L8 MCBs HA7-SPE 12<br />
Top Hat, low profile (price per rail) 3F 28.50<br />
Top Hat, high profile (price per rail) 3AF 43.75<br />
➊ Each bus bar accommodates:<br />
1 pole bus connects 57 devices<br />
2 pole bus connects 28 devices<br />
3 pole bus connects 19 devices<br />
Total current must not exceed 80A per bus.<br />
➋ Sold in packages of 10. Price indicated is price per piece.<br />
Minimum order quantity 10.<br />
3<br />
3<br />
M<br />
<strong>Circuit</strong><br />
Protection<br />
L8<br />
Discount Schedule B-8<br />
M11
Technical Data<br />
Series L8 Supplementary Protectors<br />
M<br />
<strong>Circuit</strong><br />
Protection<br />
L8<br />
Technical Data<br />
General Data B Curve C Curve D Curve<br />
Resistive or slightly resistive Inductive Loads Highly Inductive Loads<br />
Tripping Characteristic I n 3…5 x I n 5…10 x I n 10…20 x I n<br />
Approvals UR, CSA, VDE, CE UR, CSA, VDE, CE UR, VDE, CE<br />
Maximum Voltage Ratings<br />
UL/CSA<br />
IEC<br />
(All models ) IEC-EN 60 898 / VDE 0641 / DIN 43 880<br />
1-pole [V] 277VAC; 48VDC 277VAC; 48VDC 277VAC; 48VDC<br />
1-pole + neutral [V] 277VAC 277VAC 277VAC<br />
2-pole [V] 480Y/277VAC; 125VDC 480Y/277VAC; 125VDC 480Y/277VAC; 125VDC<br />
3-pole [V] 480Y/277VAC 480Y/277VAC 480Y/277VAC<br />
3-pole + neutral [V] 480Y/277VAC 480Y/277VAC 480Y/277VAC<br />
1-pole [V] 240/415VAC 240/415VAC 240/415VAC<br />
1-pole + neutral [V] 240VAC 240VAC 240VAC<br />
2-pole [V] 415VAC 415VAC 415VAC<br />
3-pole [V] 415VAC 415VAC 415VAC<br />
3-pole + neutral [V] 415VAC 415VAC 415VAC<br />
Supplementary Protector<br />
Approvals UL 1077, CSA 22.2 No. 235<br />
Current Range [A] 1…63 0.5…63 0.5…40<br />
Thermal Tripping Characteristic 1.55 x I n @ 30°C Cu 75°C<br />
Withstand Rating, 1-pole without Series Fuse [kA] 5 @ 277VAC U1<br />
Withstand Rating, Multi-pole with Series Fuse [kA] 5 @ 480Y / 277VAC C1<br />
Withstand Rating, All poles without Series Fuse [kA] 1 pole 10 @ 48VDC U1; 2 pole in series 10 @ 125VDC U1<br />
Miniature <strong>Circuit</strong> Breaker<br />
Approvals<br />
IEC / EN 60 898 (VDE) IEC / EN 60 947-2 (GL)<br />
Current Range [A] 1…63 0.5…63 0.5…40<br />
Thermal Tripping Characteristic<br />
>1 hr. at 1.13 x I n<br />
Technical Data<br />
Series L8 Supplementary Protectors<br />
Technical Data (continued)<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />
<strong>Circuit</strong> Diagrams<br />
1 pole 1 pole + neutral 2 pole 3 pole 3 pole + neutral<br />
Back up Protection<br />
Supplementary Protectors / Fuses: The following table shows the maximum short<br />
circuit current when fuses meeting the requirements of IEC 60269-1 are used as<br />
backup protection to MCBs.<br />
Miniature <strong>Circuit</strong><br />
Breaker<br />
Characteristic B<br />
Characteristic C<br />
Mechanical Data<br />
Degree of Protection<br />
Rated<br />
Current (I n )<br />
Upstream Fuse<br />
100A 160A 200A<br />
1…10A 40kA 25kA 25kA<br />
10…50A 50kA 40kA 25kA<br />
63A 50kA 40kA 10kA<br />
Mechanical endurance [ops.] 6,000 (1 operation = 2 switching movements – ON/OFF<br />
Method of mounting<br />
Supply connection<br />
Terminations<br />
Terminal type<br />
Wire size<br />
360˚<br />
360˚<br />
IP20<br />
35mm mounting rail (EN50022<br />
Line or load side<br />
solid / stranded [mm 2 ] / (AWG) 1.0…2.5 (18…8<br />
Recommended Wire Strip Length [mm] / (in.) 13 / 0.5<br />
Tightening torque [Nm] / [lb-in] 2.4 / 21.2<br />
Weight / pole [g] / [lb] 120 / 0.32<br />
Mounting Position<br />
M<br />
<strong>Circuit</strong><br />
Protection<br />
L8<br />
Discount Schedule B-8<br />
M13
Technical Data<br />
Series L8 Supplementary Protectors<br />
M<br />
<strong>Circuit</strong><br />
Protection<br />
L8<br />
Technical Data (continued)<br />
Continuous Current Rating Factor<br />
Accessories<br />
➊ When using two wires, use same cross section.<br />
Rated Diversity Factor<br />
When multiple supplementary protectors are mounted side by side, they must be<br />
derated to determine the load carrying capacity.<br />
Auxiliaries Undervoltage Release Shunt Trip<br />
Z8-AHK, NHK Z8-USA… Z8-ASA…<br />
Degree of protection (Field Wiring Terminals) IP20 (IP 00) IP20 (IP 00) IP20 (IP 00)<br />
Minimum Impulse Duration [ms] ~ ~ >15<br />
Minimum Command Time [ms] ~ ~ ≤200<br />
Operating Voltage [V] ~ U n - 115V (Z7-USA115) 12…110VAC (Z7-ASA24)<br />
U min - 50V<br />
12…60VDC<br />
~ U n - 230/240 (Z7-USA230) 110…415VAC (Z7-ASA230)<br />
U min - 110V<br />
110…230VDC<br />
Inrush Current [mA] ~ 3.6 / 44 (AC/DC) 25 / 12 (AC<br />
Dropout ~ 0.7…0.35 x U s ~<br />
15 / 2 (DC)<br />
Voltage Range [V] ~ ~ 0.7…1.1 x U s<br />
Max. operational current I e ~ ~<br />
AC13 250V [A] 3 ~ ~<br />
IEC AC15 250V [A] 2 ~ ~<br />
DC12 110V [A] 0.5 ~ ~<br />
UL1077 / AC 230V [A] 2 ~ ~<br />
CSA22.2 DC 110V [A] 0.5 ~ ~<br />
Auxiliaries Undervoltage Release Shunt Trip<br />
Z8-AHK, NHK Z8-USA… Z8-ASA…<br />
Mechanical Life-span [ops] 6000 10000 4000<br />
Terminations ➊<br />
Terminal type<br />
Wire size<br />
solid / stranded<br />
1 conductor<br />
2 conductors<br />
0.5…2.5 (18…14)<br />
0.5…2.5 (18…14)<br />
0.5…4 (18…14)<br />
0.5…2.5 (18…14)<br />
1.0…25 (18…8)<br />
1.0…4 (18…12)<br />
Tightening torque [Nm] / [lb-in] 0.8 / 7 1.1 / 10 2.4 / 21<br />
Weight [g] / [lbs] 45 / 0.1 155 / 0.4 155 / 0.4<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />
M14<br />
Discount Schedule B-8
Dimensions<br />
Series L8 Supplementary Protectors<br />
Technical Data (continued)<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />
Let-through energy I 2 t [A 2 sec]<br />
Let-through energy I 2 t [A 2 sec]<br />
80000<br />
70000<br />
60000<br />
50000<br />
40000<br />
30000<br />
20000<br />
15000<br />
10000<br />
9000<br />
8000<br />
7000<br />
6000<br />
5000<br />
4000<br />
3000<br />
2000<br />
1500<br />
1000<br />
900<br />
800<br />
700<br />
600<br />
500<br />
400<br />
300<br />
80000<br />
70000<br />
60000<br />
50000<br />
40000<br />
30000<br />
20000<br />
15000<br />
10000<br />
9000<br />
8000<br />
7000<br />
6000<br />
5000<br />
4000<br />
3000<br />
2000<br />
1500<br />
1000<br />
900<br />
800<br />
700<br />
600<br />
500<br />
400<br />
300<br />
500<br />
1000<br />
Maximum let-through energy L8<br />
Type B<br />
1500<br />
2000<br />
3000<br />
4000<br />
5000<br />
Available short-circuit current [A]<br />
Maximum let-through energy L8<br />
Type C<br />
6000<br />
7000<br />
8000<br />
9000<br />
10000<br />
15000<br />
B63<br />
B50<br />
B40<br />
B13 B16<br />
B20<br />
B25 B32<br />
B10<br />
B6<br />
B4<br />
B2<br />
C63<br />
C50<br />
C32<br />
C25 C40<br />
C16<br />
C20<br />
C13<br />
C10<br />
C6<br />
C4<br />
C3.5<br />
C3<br />
C2<br />
C2.5<br />
C1.5<br />
C1<br />
C0.5<br />
Let-through current [A]<br />
Let-through current [A]<br />
10000<br />
9000<br />
8000<br />
7000<br />
6000<br />
5000<br />
4000<br />
3000<br />
2000<br />
1500<br />
1000<br />
500<br />
10000<br />
9000<br />
8000<br />
7000<br />
6000<br />
5000<br />
4000<br />
3000<br />
2000<br />
1500<br />
1000<br />
500<br />
500<br />
Maximum let-through current L8<br />
Type B<br />
1000<br />
1500<br />
2000<br />
3000<br />
4000<br />
6000<br />
Available short circuit current [A]<br />
Maximum let-through current L8<br />
Type C<br />
7000<br />
8000<br />
9000<br />
10000<br />
15000<br />
B20B25B32B40B50B63<br />
B13<br />
B16<br />
B10<br />
B4 B6<br />
B2<br />
C63<br />
C50<br />
C40<br />
C32<br />
C25<br />
C20<br />
C16<br />
C13<br />
C10<br />
C4 C6<br />
C3 C3.5<br />
C2.5<br />
C2<br />
C1.5<br />
C1<br />
M<br />
<strong>Circuit</strong><br />
Protection<br />
500<br />
1000<br />
1500<br />
2000<br />
3000<br />
4000<br />
5000<br />
Available short-circuit current [A]<br />
6000<br />
7000<br />
8000<br />
9000<br />
10000<br />
15000<br />
500<br />
1000<br />
1500<br />
2000<br />
3000<br />
4000<br />
6000<br />
Available short circuit current [A]<br />
7000<br />
8000<br />
9000<br />
10000<br />
15000<br />
L8<br />
Discount Schedule B-8<br />
M15
Technical Data<br />
Series L8 Supplementary Protectors<br />
Technical Data (continued)<br />
M<br />
<strong>Circuit</strong><br />
Protection<br />
Let-through energy I 2 t [A 2 sec]<br />
80000<br />
70000<br />
60000<br />
50000<br />
40000<br />
30000<br />
20000<br />
15000<br />
10000<br />
9000<br />
8000<br />
7000<br />
6000<br />
5000<br />
4000<br />
3000<br />
2000<br />
1500<br />
1000<br />
900<br />
800<br />
700<br />
600<br />
500<br />
400<br />
300<br />
500<br />
1000<br />
Maximum let-through energy L8<br />
Type D<br />
1500<br />
2000<br />
3000<br />
4000<br />
5000<br />
Available short-circuit current [A]<br />
6000<br />
7000<br />
8000<br />
9000<br />
10000<br />
15000<br />
D6<br />
D40<br />
D32<br />
D20<br />
D16<br />
D25<br />
D13<br />
D10<br />
D4<br />
D2<br />
Let-through current [A]<br />
10000<br />
9000<br />
8000<br />
7000<br />
6000<br />
5000<br />
4000<br />
3000<br />
2000<br />
1500<br />
1000<br />
500<br />
500<br />
Maximum let-through current L8<br />
Type D<br />
1000<br />
1500<br />
2000<br />
3000<br />
4000<br />
6000<br />
Available short circuit current [A]<br />
7000<br />
8000<br />
9000<br />
10000<br />
15000<br />
D40<br />
D32<br />
D25<br />
D20<br />
D16<br />
D13<br />
D10<br />
D6<br />
D4<br />
D2<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />
L8<br />
M16<br />
Discount Schedule B-8
Dimensions<br />
Series L8 Supplementary Protectors<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />
• Dimensions are in millimeters<br />
• Dimensions not intended for manufacturing purposes<br />
• Dimensions are in millimeters<br />
• Dimensions not intended for manufacturing purposes<br />
• Dimensions are in millimeters<br />
• Dimensions not intended for manufacturing purposes<br />
L8 Supplementary Protectors (Series L8…B, C & D)<br />
1-pole 2-pole and 3-pole 3-pole + neutral<br />
1-pole + neutral<br />
One & Two Pole Auxiliary Contact, Signal Alarm Contact (LX-AHS3)<br />
Shunt Trip & Undervoltage Release Modules (Z8-ASA…& Z8-USA…)<br />
Shunt Trip<br />
Undervoltage Release Module<br />
M<br />
<strong>Circuit</strong><br />
Protection<br />
L8<br />
Discount Schedule B-8<br />
M17
M<br />
Series L9<br />
UL-489 Miniature<br />
<strong>Circuit</strong> Breakers<br />
Industrial <strong>Circuit</strong><br />
Breakers for Branch<br />
<strong>Circuit</strong> Protection<br />
up to 40 Amps<br />
Sprecher+Schuh includes a new line of<br />
circuit breakers approved for branch<br />
circuit applications in the United<br />
States and Canada and certified as a<br />
Miniature <strong>Circuit</strong> Breaker for IEC<br />
applications. The Sprecher + Schuh<br />
Breakers are UL489 listed and CSA<br />
22.2 No. 5.1 to provide branch <strong>Circuit</strong><br />
Breakers to IEC 60 947-2.<br />
Broad product range &<br />
flexibility<br />
The Sprecher + Schuh L9 Miniature<br />
<strong>Circuit</strong> Breakers provide a variety<br />
of product configurations by offering<br />
current ranges of 0.5A to 40A<br />
with voltage ranges of 240V AC and<br />
480Y/277V AC. The Series L9 DIN<br />
Rail-mounted circuit breakers are<br />
similar in width and current range to<br />
circuit breakers with the added benefit<br />
of providing listed branch circuit protection<br />
circuit breaker for US/Canada<br />
applications.<br />
Also available for control circuit applications<br />
are add-on auxiliary and<br />
signal contacts plus shunt trip modules<br />
to provide modern control circuit<br />
applications. A lock-off attachment is<br />
available for applications requiring that<br />
feature.<br />
Safety features provide<br />
enhanced protection<br />
The series L9 Miniature <strong>Circuit</strong> Breakers<br />
feature finger-safe IPX/2 from the<br />
front of the circuit breaker to guard<br />
against accidental contact with live<br />
parts.<br />
To aid troubleshooting, a color-coded<br />
indicator provides positive visual indication<br />
of the device status (green for OFF,<br />
red for ON and isolation function).<br />
The Series L9 also incorporate a trip<br />
free mechanism - ensuring that the<br />
device operation cannot be defeated<br />
by holding the operator in the ON<br />
position.<br />
Easy installation<br />
The Series L9 Miniature <strong>Circuit</strong> Breakers<br />
mount on a standard 35mm DINrail.<br />
Wire terminals accept multiple<br />
conductors. In addition, power to the<br />
circuit breakers can be fed from the<br />
line or load side.<br />
Global approvals for<br />
worldwide acceptance<br />
The Sprecher + Schuh L9 <strong>Circuit</strong><br />
Breakers are UL489 listed, CSA 22.2<br />
No. 5.1 approved and meets IEC<br />
60 947-2. The Series L9 also have<br />
an HACR rating (heating and air<br />
conditioning) as well as a "Switching<br />
Duty" (SWD) rating from 0.5 to 20A.<br />
Switching Duty ratings are related to<br />
fluorescent light applications only, not<br />
High intensity discharge (HID) lights<br />
or any other types of loads. Advanced<br />
features and global approvals make<br />
the Series L9 an ideal product for<br />
use in industrial equipment installed<br />
throughout the world.<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />
<strong>Circuit</strong><br />
Protection<br />
L9<br />
M18<br />
17.5mm 35mm 52.5mm<br />
(≈11/16˝) (≈1-3/8˝) (≈2-1/8˝)<br />
One Pole Two Pole Three Pole
L9 UL489 Miniature <strong>Circuit</strong> Breakers<br />
Series L9<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />
Product Design &<br />
Application<br />
The Series L9 products are thermalmagnetic<br />
(inverse time) circuit breakers<br />
offering the benefits of a modern<br />
circuit breaker design in a compact<br />
size. The L9 is used mainly in control<br />
circuit applications where branch<br />
circuit approved circuit breakers are<br />
required.<br />
Because of its range of protection<br />
(from 0.5 to 40A) many customers<br />
may use this product for protection<br />
of load devices where fuses or<br />
other supplementary protector devices<br />
previously were used in the U.S. and<br />
Canada.<br />
Protection of PLC I/O, solenoids,<br />
power supplies and control transformers<br />
along with providing the listed<br />
branch circuit protection is available in<br />
one device.<br />
Box lug terminals accept<br />
#18…#6 AWG wire as<br />
standard<br />
Current limiting and<br />
interrupting capacity up to<br />
10kA at 480Y/277V AC.<br />
Trip-free mechanism;<br />
device operation cannot<br />
be defeated by holding the<br />
operator in the ON position<br />
Color coded indicator<br />
provides visual indication<br />
of the device status and<br />
isolation function<br />
Available in one, two and<br />
three pole;<br />
Description<br />
L9 <strong>Circuit</strong> Breakers for Branch <strong>Circuit</strong><br />
protection are available one (1)-, two<br />
(2-), and three (3-) pole construction<br />
and are rated 0.5 to 40A at 240VC AC<br />
and 0.5 to 20A at 480Y/277V AC for<br />
North American applications (UL 489<br />
and CSA 22.2 No. 5.1). For IEC applications,<br />
the products are rated 415V<br />
AC 0.5 to 40A.<br />
Continuous Current Rating<br />
Standard current ratings are: 0.5A, 1A,<br />
1.5A, 2A, 3A, 4A, 5A, 6A, 7A, 8A,<br />
10A, 15A, 16A, 20A, 25A, 30A, 32A,<br />
35A and 40A.<br />
The L9 circuit breakers are rated in<br />
RMS amperes at 40°C (104°F) ambient<br />
temperature per the UL 489 (XSA<br />
22.2 No. 5.1) standard. This temperature<br />
is generally used as the average<br />
temperature within an industrial<br />
enclosure. If a circuit breaker is applied<br />
in a temperature that exceeds 40°C<br />
(104°F) ambient, then the circuit<br />
Compare these advanced features<br />
Line and load side terminals<br />
accept bus bar connections<br />
for reduced costs and more<br />
efficient installation of<br />
multiple devices.<br />
Guarded posidrive terminal<br />
screws with finger-safe<br />
protection to IEC 947-1<br />
Devices install on standard<br />
35mm DIN-rail (EN 50022)<br />
Magnetic trip elements<br />
provide Type C and D trip<br />
characteristics (IEC and EN<br />
60898), while bimetallic<br />
elements protect against<br />
slight overloads.<br />
Amp rating and trip curve<br />
characteristic clearly marked<br />
on the device for easy<br />
identification.<br />
breaker should be derated. For IEC 60<br />
947-2 standard, the products carry an<br />
ambient rating of 30 C. Follow standard<br />
IEC application considerations<br />
for temperature rating in different<br />
ambient temperatures.<br />
The characteristic trip curves are<br />
shown on page M29. The trip bands<br />
shown for each breaker represent<br />
current tripping limits for a circuit<br />
breaker and are within the limits established<br />
by UL. For a specific current<br />
at 40°C (104°F), a circuit breaker will<br />
open ("clear the circuit") automatically<br />
at some total time that will be within<br />
the "Minimum" and "Maximum"<br />
time shown on the curves.<br />
Example: The L9 time-current graph<br />
on page M29 shows that a one-pole,<br />
15 A, L9 circuit breaker trips in not<br />
less than 10 sec, and not more than<br />
120 sec. on a 30 A current. Because<br />
the UL standard defines this time<br />
spread, users should not specify exact<br />
tripping time. The lower current portion<br />
of the curves (upper left) depict<br />
the time to trip due to thermal action<br />
and reflect overload protection of the<br />
wire and connect load. The higher<br />
current portion of the curves (lower<br />
right) depicts the trip due to the magnetic<br />
action of the circuit breaker and<br />
reflects protection due to short circuit<br />
level currents.<br />
M<br />
<strong>Circuit</strong><br />
Protection<br />
L9<br />
M19
L9 UL489 Miniature <strong>Circuit</strong> Breakers<br />
Trip Characteristic C<br />
M<br />
<strong>Circuit</strong><br />
Protection<br />
Trip Characteristic C (5~10 x I N ) – Inductive loads<br />
➊<br />
UL/CSA<br />
Max.<br />
Volt.<br />
480Y/277<br />
240<br />
Rated<br />
Current<br />
(A)<br />
Catalog Number<br />
1 Pole 2 Pole 3 Pole<br />
Price<br />
Std.<br />
Pkg. Catalog Number Price<br />
Std.<br />
Pkg. Catalog Number Price<br />
0.5 L9-.5/1/C 97 2 L9-.5/2/C 185 1 L9-.5/3/C 251 1<br />
1 L9-1/1/C 97 2 L9-1/2/C 185 1 L9-1/3/C 251 1<br />
1.5 L9-1.5/1/C 97 2 L9-1.5/2/C 185 1 L9-1.5/3/C 251 1<br />
2 L9-2/1/C 97 2 L9-2/2/C 185 1 L9-2/3/C 251 1<br />
3 L9-3/1/C 97 2 L9-3/2/C 185 1 L9-3/3/C 251 1<br />
4 L9-4/1/C 97 2 L9-4/2/C 185 1 L9-4/3/C 251 1<br />
5 L9-5/1/C 97 2 L9-5/2/C 185 1 L9-5/3/C 251 1<br />
6 L9-6/1/C 97 2 L9-6/2/C 185 1 L9-6/3/C 251 1<br />
7 L9-7/1/C 97 2 L9-7/2/C 185 1 L9-7/3/C 251 1<br />
8 L9-8/1/C 97 2 L9-8/2/C 185 1 L9-8/3/C 251 1<br />
10 L9-10/1/C 97 2 L9-10/2/C 185 1 L9-10/3/C 251 1<br />
13 L9-13/1/C 97 2 L9-13/2/C 185 1 L9-13/3/C 251 1<br />
15 L9-15/1/C 97 2 L9-15/2/C 185 1 L9-15/3/C 251 1<br />
16 L9-16/1/C 97 2 L9-16/2/C 185 1 L9-16/3/C 251 1<br />
20 L9-20/1/C 97 2 L9-20/2/C 185 1 L9-20/3/C 251 1<br />
25 L9-25/1/C 107 2 L9-25/2/C 198 1 L9-25/3/C 251 1<br />
30 L9-30/1/C 110 2 L9-30/2/C 211 1 L9-30/3/C 279 1<br />
32 L9-32/1/C 110 2 L9-32/2/C 211 1 L9-32/3/C 279 1<br />
35 L9-35/1/C 110 2 L9-35/2/C 211 1 L9-35/3/C 279 1<br />
40 L9-40/1/C 115 2 L9-40/2/C 227 1 L9-40/3/C 292 1<br />
L9 Miniature <strong>Circuit</strong> Breaker Features:<br />
• UL-489 listed for Branch <strong>Circuit</strong> protection and CSSA 22.2 No. 5.1 Approved<br />
• Thermal magnetic protection<br />
• Trip characterisitc based on 40°C ambient for UL/CSA<br />
• 10kA interrupting rating<br />
• All ratings are HACR rated (SWD rated up to 20 A)<br />
• Finger safe design (front)<br />
• DIN rail mounting<br />
Std.<br />
Pkg.<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />
L9<br />
➊ Rated 415V AC IEC max/min meets IEC 60947-2 for miniature circuit breakers.<br />
M20 Discount Schedule B-8
L9 UL489 Miniature <strong>Circuit</strong> Breakers<br />
Trip Characteristic D<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />
Trip Characteristic D (10~20 x I N ) – Highly inductive loads<br />
➊<br />
UL/CSA<br />
Max.<br />
Volt.<br />
480Y/277<br />
240<br />
Rated<br />
Current<br />
(A)<br />
Catalog Number<br />
1 Pole 2 Pole 3 Pole<br />
Price<br />
Std.<br />
Pkg. Catalog Number Price<br />
Std.<br />
Pkg. Catalog Number Price<br />
0.5 L9-.5/1/D 97 2 L9-.5/2/D 186 1 L9-1,5/3/D 256 1<br />
1 L9-1/1/D 97 2 L9-1/2/D 186 1 L9-1/3/D 256 1<br />
1.5 L9-1.5/1/D 97 2 L9-1.5/2/D 186 1 L9-1.5/3/D 256 1<br />
2 L9-2/1/D 97 2 L9-2/2/D 186 1 L9-2/3/D 256 1<br />
3 L9-3/1/D 97 2 L9-3/2/D 186 1 L9-3/3/D 256 1<br />
4 L9-4/1/D 97 2 L9-4/2/D 186 1 L9-4/3/D 256 1<br />
5 L9-5/1/D 97 2 L9-5/2/D 186 1 L9-5/3/D 256 1<br />
6 L9-6/1/D 97 2 L9-6/2/D 186 1 L9-6/3/D 256 1<br />
7 L9-7/1/D 97 2 L9-7/2/D 186 1 L9-7/3/D 256 1<br />
8 L9-8/1/D 97 2 L9-8/2/D 186 1 L9-8/3/D 256 1<br />
10 L9-10/1/D 97 2 L9-10/2/D 186 1 L9-10/3/D 256 1<br />
13 L9-13/1/D 97 2 L9-13/2/D 186 1 L9-13/3/D 256 1<br />
15 L9-15/1/D 97 2 L9-15/2/D 186 1 L9-15/3/D 256 1<br />
16 L9-16/1/D 97 2 L9-16/2/D 186 1 L9-16/3/D 256 1<br />
20 L9-20/1/D 97 2 L9-20/2/D 186 1 L9-20/3/D 256 1<br />
25 L9-25/1/D 107 2 L9-25/2/D 199 1 L9-25/3/D 285 1<br />
30 L9-30/1/D 110 2 L9-30/2/D 199 1 L9-30/3/D 285 1<br />
32 L9-32/1/D 110 2 L9-32/2/D 199 1 L9-32/3/D 285 1<br />
35 L9-35/1/D 115 2 L9-35/2/D 199 1 L9-35/3/D 285 1<br />
40 L9-40/1/D 115 2 L9-40/2/D 212 1 L9-40/3/D 310 1<br />
L9 Miniature <strong>Circuit</strong> Breaker Features:<br />
• UL-489 listed for Branch <strong>Circuit</strong> protection and CSSA 22.2 No. 5.1 Approved<br />
• Thermal magnetic protection<br />
• Trip characterisitc based on 40°C ambient for UL/CSA<br />
• 10kA interrupting rating<br />
• All ratings are HACR rated (SWD rated up to 20 A)<br />
• Finger safe design (front)<br />
• DIN rail mounting<br />
Std.<br />
Pkg.<br />
M<br />
<strong>Circuit</strong><br />
Protection<br />
➊ Rated 415V AC IEC max/min meets IEC 60947-2 for miniature circuit breakers.<br />
L9<br />
Discount Schedule B-8<br />
M21
Accessories<br />
Series L9 UL489 Miniature <strong>Circuit</strong> Breakers<br />
M<br />
<strong>Circuit</strong><br />
Protection<br />
L9<br />
Accessories<br />
Module<br />
Auxiliary<br />
LX-AHS3<br />
X<br />
X<br />
+<br />
Shunt<br />
L9-<strong>AA</strong>ST...<br />
X<br />
X<br />
Description<br />
Selectable Two Pole Auxiliary Contact or<br />
Auxiliary / Signal Alarm Module –<br />
• Small set-screw alternates between<br />
operational modes<br />
• Two Form C (two changeover contacts)<br />
• Installs on left side of L9<br />
• Auxiliary contact switches when L9 is<br />
operated manually or tripped electrically<br />
• Signal Alarm contact switches only when<br />
L9 is tripped electrically<br />
Shunt Trip –<br />
• Remotely trips the device<br />
• Installs on left side of L9<br />
Padlock Hasp –<br />
• Fits securely over switch handle. Prevents<br />
unauthorized activation of L9 during<br />
maintenance<br />
DIN-rail - 2 meter lengths (6' 6")<br />
For use<br />
with…<br />
All L9s<br />
& Shunt<br />
Trip<br />
All L9s<br />
110…415VAC<br />
12…110VAC<br />
Connection<br />
Diagrams Catalog Number Price<br />
Two pole auxiliary mode<br />
Auxiliary / Signal alarm mode<br />
LX-AHS3 71<br />
L9-ASTA1<br />
L9-ASTA2<br />
All L9s L9-<strong>AA</strong>LOA 20<br />
Top Hat, low profile (price per rail) 3F 28.50<br />
Top Hat, high profile (price per rail) 3AF 43.75<br />
L9-...<br />
Allowable Combinations of Accessories per Supplementary Protectors →<br />
(read left to right)<br />
X<br />
X<br />
X<br />
Allowable Combinations of Field Installed Modules<br />
(1) Selectable Two Pole Auxiliary Contact Module / Auxiliary & Signal Alarm<br />
Contact Module<br />
(1) Shunt Trip Module<br />
(1) Auxiliary Contact Module + (1) Shunt Trip Module<br />
All modules install on the left side of the Supplementary Protectors.<br />
76<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />
M22 Discount Schedule B-8
Technical Data<br />
Series L9 UL489 Miniature <strong>Circuit</strong> Breakers<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />
Technical Data<br />
General Data<br />
Number of Poles 1, 2 and 3<br />
Standards UL 489<br />
Certifications<br />
CSA 22.2 No. 5.1<br />
IEC 60 947-2<br />
UL Listed <strong>Circuit</strong> Breaker<br />
CSA Certified, CE<br />
HACR Rating (USA/Canada)<br />
Yes<br />
SWD Rating (USA/Canada) Yes (0.5...20 A)<br />
Calibration Temperature 40°C<br />
Rated Interrupting Capacity<br />
Rated Tripping Current<br />
Degree of Protection<br />
Normal Operating Environment<br />
Trip Curves<br />
Shipment and Short-Term Storage Limits<br />
Wire Size<br />
Terminal Torque<br />
Recommended Wire Strip Length<br />
Auxillaries<br />
Auxiliary Contact,<br />
2 sets, each are Form C,<br />
1 NO & 1 NC<br />
LX-AHS3<br />
UL/CSA: 10 000 AIC<br />
IEC - lcu: 10 000 A<br />
UL/CSA: 0.5...20 A, 480Y/277V AC<br />
0.5...40 A, 240V AC<br />
IEC: 0.5...40 A, 415V AC<br />
Finger-safe from front:<br />
-IP20 per IEC 529 from front<br />
-IP00 at wire terminals<br />
-25...55°C (23...104°F) (non-condensing)<br />
C curve (inductive) 5...10 IN<br />
D curve (Highly inductive) 10...20 IN<br />
-40..85°C (-40...185°F)<br />
1 wire: #18...6 AWG<br />
2 wire: #18...10 AWG<br />
#18...12 AWG: 21 lb-in<br />
#10...8 AWG: 25 lb-in<br />
#6 AWG: 36 lb-in<br />
0.5 in<br />
Shunt Trip Module<br />
L9-ASTA1<br />
Shunt Trip Module<br />
L9-ASTA2<br />
CSA/UL Certifications Yes Yes Yes<br />
IEC 60 947-2 Compliance Yes Yes Yes<br />
CE Yes Yes Yes<br />
IEC Max. Voltage 250V AC 110...415V AC 12...110V AC<br />
UL/CSA Max. Voltage 240V AC ➊ 110...415V AC 12...110V AC<br />
Connection Cable Cable Cable<br />
Mechanical Life-span<br />
Aux...LX-AHS3<br />
Shunt Trip L9-<strong>AA</strong>STA...<br />
Terminations [ops) 6000 4000<br />
Terminal type<br />
Wire size<br />
1 conductor 0.5...2.5 (18...14) 1.0...6 (18...10)<br />
solid /stranded 2 conductors 0.5...2.5 (18...14) 1.0...6 (18...10)<br />
Tightening torque [Nm] / [lb-in] 0.8 / 7 2.8 / 25<br />
Weight [g] / [lbs] 45 / 0.1 155 / 0.4<br />
M<br />
<strong>Circuit</strong><br />
Protection<br />
➊ Use of auxiliary or signal contact limits the circuit breaker to a maximum voltage of 240V AC for UL/CSA applications.<br />
L9<br />
Discount Schedule B-8<br />
M23
Dimensions<br />
Series L9 UL489 Miniature <strong>Circuit</strong> Breakers<br />
M<br />
<strong>Circuit</strong><br />
Protection<br />
L9<br />
• Dimensions are in millimeters<br />
• Dimensions not intended for manufacturing purposes<br />
1 pole 2 pole 3 pole<br />
• Dimensions are in millimeters<br />
• Dimensions not intended for manufacturing purposes<br />
• Dimensions are in millimeters<br />
• Dimensions not intended for manufacturing purposes<br />
L9 Miniature <strong>Circuit</strong> Breakers (Series L9…C & D)<br />
Two Pole Auxiliary Contact, Signal Alarm Contact (LX-AHS3)<br />
Shunt Trip (L9-<strong>AA</strong>STA...)<br />
Shunt Trip<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />
M24 Discount Schedule B-8
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />
Methods of Applying<br />
<strong>Circuit</strong> Protection<br />
This information is provided to aid in proper system design and utilization<br />
of circuit protection devices in North American applications.<br />
Be sure to consider all applicable local and national codes for your<br />
particular installation.<br />
M<br />
<strong>Circuit</strong><br />
Protection<br />
M25
<strong>Circuit</strong> Protection Methods<br />
Series L8 Supplementary Protectors<br />
Applying L8 Supplementary Protectors in accordance with UL & NEC Guidelines (continued)<br />
M<br />
<strong>Circuit</strong><br />
Protection<br />
Secondary Supplementary Protectors Selection<br />
• 50VA/120V = 0.42A rated transformer secondary current<br />
• 0.42A is less than 9, therefore may increase up to 167%<br />
• 0.42A x 167% =0.70A, Select L8-1/1/D or L8-1/1/C<br />
(1 amp 1-Pole)<br />
Secondary Control Transformer Calculations (120 / 24V)<br />
Transformer<br />
VA<br />
Secondary<br />
Volts<br />
Rated<br />
Amps ➊<br />
Selected<br />
L8 Mini-CB<br />
50 120 0.42 1<br />
100 120 0.83 2<br />
150 120 1.25 2<br />
200 120 1.67 3<br />
250 120 2.08 4<br />
300 120 2.50 4<br />
500 120 4.17 7<br />
1000 120 8.33 13<br />
50 24 2.08 4<br />
100 24 4.17 7<br />
150 24 6.25 10<br />
200 24 8.33 13<br />
250 24 10.42 13<br />
300 24 12.50 16<br />
500 24 20.83 30<br />
1000 24 41.67 50<br />
Protection of Control <strong>Circuit</strong> Devices<br />
Control circuit devices can also generate inrush currents during<br />
startup, though not as intense as control transformers. Devices such as<br />
control relays, starter coils, and solenoids exhibit typical inrush levels<br />
between 6~10 x In. Also, protection of conductor wires or low-level<br />
signal devices such as PLCs may exhibit even lower inrush levels<br />
ranging from 3~5 x In. Depending on the inrush, an Mini-CB with a<br />
type “B” or “C” trip characteristic will perform the task.<br />
Control <strong>Circuit</strong> Conductor Protection<br />
The relationship between the control circuit conductor size and<br />
rating of the protective device must be in compliance with the<br />
tabulated data per UL 508.<br />
(Reference: UL 508A procedure prescribed only)<br />
Where can supplementary overcurrent<br />
protectors not be used?<br />
• Branch <strong>Circuit</strong> Protection Device (BCPD)<br />
• Power Transformer Primary Protection<br />
• Power Transformer Secondary Protection<br />
• Protection of Loads such as for <strong>Motor</strong>s, Heater, Lamps, and<br />
General use<br />
Supplementary protectors may be submitted to UL for further investigation<br />
for other uses.<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />
FH7<br />
➊ If the rated secondary current is less than 9 amps, the maximum rating of the overcurrent<br />
device is 167%. If 9 amps or more, the maximum rating of the overcurrent<br />
device is 125%.<br />
M26<br />
Discount Schedule B-7
<strong>Circuit</strong> Protection Methods<br />
Series L8 Supplementary Protectors<br />
Applying L8 Supplementary Protectors in accordance with UL & NEC Guidelines<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />
Sprecher+Schuh Series L8 Supplementary Protectors are recognized<br />
by Underwriters Laboratories (UL). Representative samples of this<br />
product have been evaluated by UL and meet applicable US safety<br />
standards. In general, the UL Component Recognition service covers<br />
the evaluation of components that will later be used in a complete<br />
product or system. L8 Supplementary Protectors are defined as UL<br />
Recognized supplementary overcurrent protective devices under the<br />
standard of UL 1077.<br />
UL 508A, a procedure covering industrial control panels, offers guidelines<br />
in applying supplementary overcurrent protective devices. The<br />
general areas of acceptability are in the primary and secondary protection<br />
of control transformers, and also control circuit protection. Other<br />
uses of Mini-CB’s may be submitted to UL for further investigation.<br />
Per UL 508A, before utilizing a supplementary device for control<br />
transformer overcurrent protection, the supplementary device<br />
must meet the following restrictions:<br />
Unless otherwise specified it is used with protection, either fuse or<br />
circuit breakers upstream from the supplementary device, rated<br />
at 400 percent of the supplementary protector rating but not less<br />
than 20A for device rated 150V or less and 15A for devices rated<br />
150V or more.<br />
(Reference: UL 508A procedure prescribed only)<br />
Protection of Control Transformers<br />
Control transformers can generate an almost infinite current spike<br />
on start-up while attempting to overcome core saturation. Only the<br />
resistance of the control transformer windings and the inductance of<br />
the circuit limit the large current draw. The inrush spikes are of short<br />
duration (1/8 to 1/4 of a cycle), typically reaching between 8~20 x<br />
I n . Therefore, selecting a Mini-CB with the proper current rating and<br />
high inrush trip characteristics is ideal to avoid nuisance tripping.<br />
Sprecher+Schuh Series L8 “C” & “D” type Supplementary Protectors<br />
offer high inrush capabilities from 5~10 x I n and 10~20 x I n respectively.<br />
Selecting the proper Mini-CB current ratings for the primary and secondary<br />
protection of control transformers (per UL/NEC) is as follows:<br />
Primary Overcurrent Protection for Control Transformers<br />
Control <strong>Circuit</strong>s: If the rated primary current is less than 2<br />
amps, the maximum rating of the overcurrent device is 500%.<br />
If the rated primary current is more than 2 amps, the maximum<br />
rating of the overcurrent device is 250%.<br />
Secondary Overcurrent Protection for Control Transformers<br />
Control <strong>Circuit</strong>s: If the rated secondary current is less than 9<br />
amps, the maximum rating of the overcurrent device is 167%.<br />
If 9 amps or more, the maximum rating of the overcurrent<br />
device is 125%. The next larger size of an overcurrent device<br />
may be used if 125% does not correspond to a standard size.<br />
(Reference: UL 508 32.7, UL 845 11.16 & 11.17, NEC 430-72(c)<br />
exception No. 2, 450-3(b) 1 & 2)<br />
Example (see table for more calculated results)<br />
Primary & Secondary Protection of a Control Transformer:<br />
50VA Pri. 480/ Sec. 120V<br />
Primary Mini-CB Selection<br />
• 50VA/480V = 0.10A rated transformer primary current<br />
• 0.10A is less than 2, therefore may increase up to 500%<br />
• 0.10A x 500% = 0.52A, Select L8-.5/2/D (0.5 amp 2-Pole)<br />
• Upstream BCPD must be rated at 400% of the selected Mini-CB<br />
rating<br />
• 0.5A x 400% = 2A, since rated below 15A at 150V or more, the<br />
minimum BCPD is 15A per NEC-240.6<br />
Primary Control Transformer Calculations (480 / 240V)<br />
Transformer<br />
VA<br />
Primary<br />
Volts<br />
Rated<br />
Amps ➊<br />
Selected<br />
L8 Mini-CB<br />
Maximum<br />
Upstream<br />
BCPD ➋<br />
50 480 0.10 0.5 15A<br />
100 480 0.21 1 15A<br />
150 480 0.31 1 15A<br />
200 480 0.42 2 15A<br />
250 480 0.52 2 15A<br />
300 480 0.63 3 15A<br />
500 480 1.04 5 25A<br />
1000 480 2.08 5 25A<br />
50 240 0.21 1 15A<br />
100 240 0.42 2 15A<br />
150 240 0.63 3 15A<br />
200 240 0.83 4 15A<br />
250 240 1.04 5 25A<br />
300 240 1.25 6 25A<br />
500 240 2.08 5 25A<br />
1000 240 4.17 10 60A<br />
➊ If the rated primary current is less than 2 amps, the maximum rating of the<br />
overcurrent device is 500%. If the rated primary current is more than 2 amps, the<br />
maximum rating of the overcurrent device is 250%.<br />
➋ Minimum standard BCPD ampere rating is 15A per NEC-240.6.<br />
M<br />
<strong>Circuit</strong><br />
Protection<br />
L8<br />
Discount Schedule B-8<br />
M27
<strong>Circuit</strong> Protection Methods<br />
Series L9 UL489 Miniature <strong>Circuit</strong> Breakers<br />
M<br />
<strong>Circuit</strong><br />
Protection<br />
Applying L9 UL489 Miniature <strong>Circuit</strong> Breakers in accordance with UL & NEC Guidelines<br />
Description<br />
L9 <strong>Circuit</strong> Breakers for Branch <strong>Circuit</strong> protection are available one (1)-,<br />
two (2-), and three (3-) pole construction and are rated 0.5 to 40A at<br />
240VC AC and 0.5 to 20A at 480Y/277V AC for North American<br />
applications (UL 489 and CSA 22.2 No. 5.1). For IEC applications, the<br />
products are rated 415V AC 0.5 to 40A.<br />
Thermal Magnetic <strong>Circuit</strong> Breakers<br />
The L9 Thermal Magnetic <strong>Circuit</strong> Breakers are general-purpose devices suitable<br />
for the majority of industrial, inverse time circuit breaker applications.<br />
<strong>Circuit</strong> Breaker Application Information<br />
Selection of a L9 circuit breaker with appropriate circuit protection includes<br />
consideration of:<br />
● <strong>Circuit</strong> Voltage<br />
● <strong>Circuit</strong> Frequency<br />
● Available Short <strong>Circuit</strong> Current<br />
● Continuous Current Rating<br />
● Application Considerations<br />
● Special Operating Conditions<br />
<strong>Circuit</strong> Voltage<br />
The L9 circuit breakers are rated by voltage class. Applications should not<br />
exceed the listed voltage and current range.<br />
<strong>Circuit</strong> Frequency<br />
The L9 circuit breakers may be applied to frequencies of 50 and 60 Hz without<br />
derating. For applications above 60 Hz, contact Sprecher + Schuh with<br />
specific application information for the derating of the circuit breakers.<br />
Available Short <strong>Circuit</strong> Current<br />
The L9 circuit breakers should only be applied in those applications in<br />
which the available short-circuit (or fault) current is less than or equal to<br />
10,000 A.<br />
Region Max. Voltage Current Range<br />
IEC Regions 415V AC 0.5..40A<br />
North America 240V AC 0.5...40A<br />
(UL 489 & CSA<br />
22.2 No. 5.1) 480Y/277V AC 0.5...20A<br />
Application Considerations<br />
The selection of a specific ampere rating for a specific application is<br />
dependent on the type of load and duty cycle and is governed by the<br />
National <strong>Electric</strong> Code (Canadian <strong>Electric</strong> Code) and UL/CSA. In<br />
general, the codes require that overcurrent protection is at the current<br />
supply and at points where wire sizes are reduced. In addition, the<br />
codes state that conductors be protected according to their current<br />
carrying capacity. There are specific situations that require application<br />
consideration, such as motor circuit, and guidelines for the selection<br />
for transformer protection.<br />
The L9 circuit breakers are "non 100% rated" as defined UL 489, para<br />
7.1.4.2. As such, the circuit breaker's rating should be loaded to no<br />
more than 80% if used with continuous loads.<br />
Branch <strong>Circuit</strong>s<br />
L9 circuit breakers may be used to protect branch circuits. A branch<br />
circuit is the wiring portion of a system extending beyond the final<br />
overcurrent device protecting the circuit. Guidelines established in<br />
NEC, CED, UL and CSA should be used to determine the specific<br />
device.<br />
1. <strong>Motor</strong> Branch <strong>Circuit</strong><br />
L9 circuit breakers are not horsepower rated because they are able<br />
to safely interrupt currents far in excess of the locked rotor value<br />
for a selected motor. This ability is recognized in the codes and<br />
standards and is also established by the UL and CSA tests described<br />
in UL 489 and CSA 22.2 No 5.1 standards.<br />
2. Transformer Protection<br />
L9 circuit breakers may be used for transformer protection following<br />
the guidelines established. References: NEC 450 and UL 489.<br />
Also see CEC and appropriate Canadian Standards. References:<br />
NEC 450 and UL 489. Also see CEC and appropriate Canadian<br />
Standards.<br />
3. Heater Load, Lighting, and Other Load Protection<br />
L9 circuit breakers may be used for protection of heater loads,<br />
lighting loads and other loads following the guidelines established.<br />
References: NED Article 31 and UL 508A. Also see CEC and appropriate<br />
Canadian Standards.<br />
Coordinated Overcurrent Protection<br />
Where an orderly shutdown is required to minimize the hazards to<br />
personnel and equipment, a system of coordination based upon the<br />
faulted or overloaded circuit is isolated by selective operation of only<br />
the overcurrent protective device closest to the overcurrent condition.<br />
The user should select devices that meet this requirement. References:<br />
NEC 240.12. Also see CEC.<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />
L9<br />
M28
<strong>Circuit</strong> Protection Methods<br />
Series L9 UL489 Miniature <strong>Circuit</strong> Breakers<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />
Applying L9 UL489 Miniature <strong>Circuit</strong> Breakers in accordance with UL & NEC Guidelines (continued)<br />
Determining Ratings<br />
The standard tripping characteristics for the L9 Series is Type C Type C has a magnetic trip activated at 5...10 times the rated current of the circuit<br />
breaker. The reference temperature for the thermal tripping characteristics is 40°C. The Type C characteristics will suit most applications.<br />
In rare occurrences when the Type C characteristics does not fully meet the application, the following additional magnetic trip characteristics is available.<br />
Type D allows for transient approximately twice as high as the standard Type C. Use the table and graphs to determine the current rating for the<br />
breaker if the ambient is significantly different than 40°C.<br />
Load Factor K T [I/I n ]<br />
Device Marked<br />
In (A) at higher Ambient Temperature<br />
Current Rating in<br />
(A) @ 40°C<br />
15°C 20°C 25°C 30°C 40°C 50°C 55°C<br />
0.5 0.6 0.5 0.5 0.5 0.5 0.5 0.5<br />
1.0 1.1 1.1 1.1 1.0 1 1.0 0.9<br />
1.5 1.7 1.6 1.6 1.6 1.5 1.4 1.4<br />
2.0 2.2 2.2 2.1 2.1 2 1.9 1.9<br />
3.0 3.3 3.2 3.2 3.1 3 2.9 2l.8<br />
4.0 4.4 4.3 4.2 4.2 4 3.8 3.8<br />
5.0 5.5 5.4 5.3 5.2 5 4.8 4.7<br />
6.0 6.6 6.5 6.4 6.2 6 5.8 5.6<br />
7.0 7.7 7.6 7.4 7.3 7 6.7 6.6<br />
8.0 8.8 8.6 8.5 8.3 8 7.7 7.5<br />
10.0 11.0 10.8 10.6 10.4 10 9.6 9.4<br />
13.0 14.3 14.0 13.8 13.5 13 12.5 12.2<br />
15.0 16.5 16.2 15.9 15.6 15 14.4 14.1<br />
16.0 17.6 17.3 17.0 16.6 16 15.4 15.0<br />
20.0 22.0 21.6 21.2 20.8 20 19.2 18.8<br />
25.0 27.5 27.0 26.5 26.0 25 24.0 23.5<br />
30.0 33.0 32.4 31.8 31.2 30 28.8 28.2<br />
32.0 35.2 34.6 33.9 33.3 32 30.7 30.1<br />
40.0 44.0 43.2 42.4 41.6 40 38.4 37.6<br />
Note: The table shows the corrected values of the rated current dependent on the ambient temperature.<br />
1.40<br />
1.30<br />
1.20<br />
1.10<br />
1.00<br />
0.90<br />
Influence of Ambient Temperature (T)<br />
on Load-Carrying Capacity<br />
-20 -10 0 10 20 30 50 50<br />
Ambient Temperature T [°C]<br />
Maximum load I at Ambient Temperature T:<br />
L<br />
I L(T) = I n K T (T)<br />
t [sec]<br />
7200<br />
3600<br />
1<br />
1200<br />
600<br />
300<br />
120<br />
60<br />
30<br />
10<br />
5<br />
2<br />
1<br />
0.5<br />
0.2<br />
0.1<br />
0.05<br />
0.02<br />
0.01<br />
0.005<br />
0.002<br />
0.001<br />
0.0005<br />
2<br />
3<br />
3<br />
Time-Current Characteristic L9<br />
Type C and D<br />
Ambient Temperature 40°C<br />
4 5<br />
4 5<br />
Tripping characteristic<br />
acc. to UL 489<br />
1 conventional non-tripping current<br />
Int = 1.0 I (TN =40°C)<br />
2 conventional tripping current<br />
It = 1.35 I : tN < 1 h (T=25°C)<br />
3 2.0 I : tN = 12- 120 s (T=25°C)<br />
4<br />
6<br />
Instantaneous Tripping<br />
acc. to IEC 60898-1<br />
type C: 5 I : t > 0.1N s<br />
10 I : t < 0.1N s<br />
type D: 10 I : t > 0.1N s<br />
20 I : t < 0.1N s<br />
M<br />
<strong>Circuit</strong><br />
Protection<br />
L9<br />
1 2 3 4 5 6 7 8 9 10 15 20 30 40 50<br />
I / I<br />
N<br />
M29
<strong>Circuit</strong> Protection Methods<br />
Series L8 and L9<br />
Defining <strong>Electric</strong>al Standards Relating to Supplementary Protectors<br />
M<br />
<strong>Circuit</strong><br />
Protection<br />
➊<br />
➐<br />
➊ Branch <strong>Circuit</strong> Protection Device (BCPD)<br />
Acceptable components<br />
• Branch circuit protection device (UL489)<br />
• Self-protected Type E manual motor controller<br />
➋ Control Transformer Primary Protection<br />
Acceptable components<br />
• UL-1077 supplementary protective device<br />
• Self-protected Type E manual motor controller<br />
• UL-listed fuses<br />
➌ Control Transformer Secondary Protection<br />
Acceptable components<br />
• UL-1077 supplementary protective device<br />
• Self-protected Type E manual motor controller<br />
• Miscellaneous, miniature and micro fuses<br />
➍ Supplementary <strong>Circuit</strong> Protection<br />
Acceptable components<br />
• UL-1077 supplementary protective device<br />
• Miscellaneous, miniature and micro fuses<br />
➌<br />
➍<br />
➎ Power Transformer Fuse/Branch <strong>Circuit</strong><br />
Protection<br />
Acceptable components<br />
• Branch circuit protection device or power-related transformer<br />
fuses (UL489)<br />
• Self-protected Type E manual motor controller<br />
➏ Power Transformer Fuse/Branch <strong>Circuit</strong><br />
Protection<br />
Acceptable components<br />
• Branch circuit protection device or power-related transformer<br />
fuses (UL489)<br />
• Self-protected Type E manual motor controller<br />
➋<br />
➊<br />
➊<br />
➎<br />
➏<br />
➐<br />
➌<br />
➍<br />
L10 Disconnect Switch<br />
<strong>KT7</strong> <strong>Motor</strong> <strong>Circuit</strong> Protector<br />
V7 Fuse Blocks<br />
➏<br />
➐<br />
➎<br />
Sprecher + Schuh Products<br />
➋<br />
➌<br />
➍<br />
➎<br />
➏<br />
➋<br />
➍<br />
➊<br />
➋<br />
➎<br />
➏<br />
FH7 Fuse Holder<br />
L8 Supplementary Protector<br />
L9 Miniature <strong>Circuit</strong> Breaker<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />
L9<br />
➐ <strong>Motor</strong> Load Protection<br />
• <strong>Manual</strong> motor controllers (UL508)<br />
M30 Discount Schedule B-8
<strong>Circuit</strong> Protection Methods<br />
Series L8 and L9<br />
Defining <strong>Electric</strong>al Standards Relating to Supplementary Protectors<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />
<strong>Circuit</strong> protection devices should be applied in accordance with the<br />
product specifications, as well as local and national electrical codes.<br />
Sprecher+Schuh breakers offer equipment manufacturers a product<br />
that meets both US and international protection standards. A variety<br />
of Sprecher+Schuh Supplementary Protectors are approved by Underwriters<br />
Laboratory’s UL 1077 supplementary standards and are<br />
applicable for use under the guidelines of the National <strong>Electric</strong> Code<br />
(NEC). Internationally, Sprecher+Schuh Supplementary Protectors<br />
are CE marked and meet CSA and IEC standards for worldwide acceptance.<br />
Sprecher+Schuh Supplementary Protectors are an excellent choice<br />
for supplementary protection. See the listings below to gain a<br />
broader understanding of additional electrical standards pertaining to<br />
other types of Supplementary Protectors.<br />
UL 508 <strong>Manual</strong> <strong>Motor</strong> <strong>Controllers</strong><br />
A manual motor controller is suitable for use as an ON/OFF<br />
R<br />
(make/break) controller for motors and other loads. These<br />
devices also have an overload tripping function which must be<br />
compliant with applicable tests for an overload relay. In addition, an<br />
overload tripping device must operate independently of the manipulation<br />
of the handle (trip free).<br />
A listed <strong>Manual</strong> <strong>Motor</strong> Controller, additionally marked “Suitable as<br />
a <strong>Motor</strong> Disconnect,” shall be permitted as a disconnecting means<br />
where installed between the final motor branch-circuit short-circuit,<br />
transformer protection, device and the motor. General uses: control<br />
circuit, transformer protection, motor loads, general use loads, lighting<br />
loads, resistive loads.<br />
Although Sprecher+Schuh Supplementary Protectors are not listed as<br />
UL 508 manual motor controllers, Sprecher + Schuh offers our <strong>KT7</strong><br />
<strong>Motor</strong> Controller series, which does meet the UL 508 standard at a<br />
competitive price.<br />
UL 489 Branch <strong>Circuit</strong> Protection<br />
Products UL Listed for Branch <strong>Circuit</strong> Protection, which are<br />
approved and evaluated according to the UL 489 Standard<br />
R<br />
for “Molded Case <strong>Circuit</strong> Breakers” (usually applicable at 240V<br />
maximum when associated with Supplementary Protectors). General<br />
uses: Branch <strong>Circuit</strong> Protection Device (BCPD), protect motor loads,<br />
protect external loads such as receptacles or HVAC & refrigeration<br />
equipment.<br />
Although Sprecher+Schuh Supplementary Protectors are not listed as<br />
UL 489 branch circuit protectors, Sprecher + Schuh offers our <strong>KT7</strong><br />
<strong>Motor</strong> Controller series which is approved as a self-protected combination<br />
motor controller under UL 508 and therefore can be applied as<br />
a branch circuit protection device.<br />
CSA C22.2 No. 5.1<br />
Products evaluated according to the Canadian Standards<br />
Association (CSA), which are intended to protect branch circuits<br />
in accordance with the Canadian <strong>Electric</strong> Code (CEC). The CSA<br />
C22.2 No. 5.1 standard is closely related to the UL 489 standard.<br />
UL 1077 Supplementary Protection<br />
UL recognized supplementary protectors evaluated according<br />
to UL 1077 standard. Supplementary protectors are intended<br />
for use as overcurrent protection within an appliance or other electrical<br />
equipment where branch circuit protectors shall not be used as<br />
substitutes for UL 489 branch circuit protective devices. General uses:<br />
control circuit components such as relay coils, starter coils, timers and<br />
remote solenoids... etc.; control transformers protection (primary &<br />
secondary); sensitive internal electronic circuitry.<br />
CSA C22.2 No. 235<br />
The CSA C22.2 No. 235 Standard is closely related to the UL<br />
1077 Supplementary Protector standard.<br />
IEC 60947-2 Standard<br />
<strong>Electric</strong>al standards for industrial applications using circuit<br />
protection.<br />
M<br />
<strong>Circuit</strong><br />
Protection<br />
L9<br />
Discount Schedule B-8<br />
M31
Notes<br />
Series L8 and L9<br />
Notes<br />
M<br />
<strong>Circuit</strong><br />
Protection<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />
L9<br />
M32 Discount Schedule B-8
R<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />
Series FH7<br />
DIN-rail Mounted<br />
Fuse Holders<br />
The new design<br />
standard for fuse block<br />
overcurrent protection<br />
New FH7 Fuse Holders have a<br />
completely enclosed design that<br />
makes changing fuses simple<br />
and safe<br />
Sprecher + Schuh’s new FH7 Fuse<br />
Blocks feature the latest enclosed design<br />
for the ultimate in safety and convenience.<br />
Built for control and power<br />
circuits, the FH7 line is DIN-rail<br />
mountable, compact and reliable. Both<br />
AC and DC models are available, with<br />
and without blown fuse indication.<br />
Sized for many applications<br />
FH7 Fuse Blocks are available in one,<br />
two and three pole configurations for<br />
the following fuse types:<br />
• Class CC<br />
• Midget; 1-1/2 x 13/32<br />
• DC rated fuses up to 30A<br />
• Class J 30A fuses<br />
• Class J 60A fuses<br />
All AC fuse blocks are rated to 600V,<br />
with 24 and 48V DC models available<br />
for midget fuses. All devices carry<br />
a withstand rating to 200kA. Midget<br />
fuse blocks are rated to 100kA.<br />
New enclosed design offers<br />
many advantages<br />
Unlike “open” fuse blocks of the past<br />
that were extremely dangerous, the<br />
enclosed design of the FH7 series<br />
features IP2 dead-front construction<br />
under IEC and DIN standards. In<br />
operation, there is no access to live<br />
fuses or fuse clips. With the flick of<br />
a finger, fuse access is gained via a levered<br />
compartment on the front of the<br />
holder that isolates the fuse from the<br />
line power. This makes fuse changeout<br />
quick, easy, convenient... and safe.<br />
Other great features<br />
The FH7 line is compact, saving up to<br />
15% in panel space over conventional<br />
fuse blocks. The entire line is also<br />
DIN-rail mountable, resulting in extra<br />
savings in panel building time. All<br />
models are available with blown fuse<br />
indication, saving time on maintenance<br />
and troubleshooting. The bodies<br />
are made up of tough and durable<br />
polyamide, known for its exceptional<br />
insulating properties.<br />
International approvals<br />
Class CC and J fuse holders are UL<br />
listed for branch circuit protection in<br />
electrical distribution systems. They<br />
are excellent for small motor loads<br />
and group protection of small motors.<br />
Midget holders are UL recognized.<br />
The entire line is CSA Approved and<br />
carries the CE Mark for use in international<br />
markets.<br />
M<br />
<strong>Circuit</strong><br />
Protection<br />
17.5mm 17.5mm 37.5mm 40mm<br />
(≈11/16˝) (≈11/16˝) (≈1-15/32˝) (≈1-9/16˝)<br />
Midget Class CC Class J (30A) Class J (60A)<br />
M33<br />
FH7
Series FH7 Fuse Holders<br />
For Midget Fuses<br />
M<br />
<strong>Circuit</strong><br />
Protection<br />
DIN-rail Mounted Fuse Holders – Midget Fuses (13/32 x 1-1/2) ➊<br />
Ordering and<br />
Technical<br />
Information<br />
Fuse Block -<br />
Without Blown Fuse LED<br />
With Blown Fuse LED<br />
24V DC (with LED indicator)<br />
48V DC (with LED indicator)<br />
DIN-rail<br />
Top Hat, low profile (priced per rail)<br />
Top Hat, high profile (priced per rail)<br />
End Anchors<br />
DIN Rail — Normal Duty<br />
DIN Rail — Heavy Duty<br />
Catalog Number<br />
FH7-1PM30<br />
FH7-1PM30-L<br />
FH7-1PM30-D1<br />
FH7-1PM30-D2<br />
3F<br />
3AF<br />
V7-EA35<br />
V7-EAH35<br />
One Pole<br />
2.13"<br />
0.69" (17.5mm) (54mm)<br />
Price Ea.<br />
(Std Pkg)<br />
11.40<br />
16.90<br />
16.90<br />
16.90<br />
17.00<br />
26.00<br />
1.15<br />
4.35<br />
Pkg<br />
Qty<br />
6<br />
6<br />
6<br />
6<br />
Catalog Number<br />
FH7-2PM30<br />
FH7-2PM30-L<br />
Accessories<br />
12<br />
12<br />
50<br />
10<br />
3F<br />
3AF<br />
V7-EA35<br />
V7-EAH35<br />
Two Pole<br />
2.13"<br />
1.38" (35mm) (54mm)<br />
Price Ea.<br />
(Std Pkg)<br />
23.30<br />
34.80<br />
17.00<br />
26.00<br />
1.15<br />
4.35<br />
Pkg<br />
Qty<br />
3<br />
3<br />
12<br />
12<br />
50<br />
10<br />
Catalog Number<br />
FH7-3PM30<br />
FH7-3PM30-L<br />
3F<br />
3AF<br />
V7-EA35<br />
V7-EAH35<br />
Three Pole<br />
2.13"<br />
2.07" (52.5mm) (54mm)<br />
Price Ea.<br />
(Std Pkg)<br />
Fuse Block Specifications<br />
Approvals<br />
Voltage Rating 600V AC/DC 600V AC/DC 600V AC/DC 600V AC/DC 600V AC/DC 600V AC/DC<br />
Maximum Current 30 A 30 A 30 A 30 A 30 A 30 A<br />
Wire Range (Rated Cross Section) #14–#6 AWG<br />
2.5…16mm 2<br />
#14–#6 AWG<br />
2.5…16mm 2<br />
#14–#6 AWG<br />
2.5…16mm 2<br />
#14–#6 AWG<br />
2.5…16mm 2<br />
#14–#6 AWG<br />
2.5…16mm 2<br />
#14–#6 AWG<br />
2.5…16mm 2<br />
Wire Strip Length 0.5" (12.7 mm) 0.5" (12.7 mm) 0.5" (12.7 mm)<br />
Recommended Tightening Torque 15 lb-in. (1.7 Nm) 15 lb-in. (1.7 Nm) 15 lb-in. (1.7 Nm)<br />
Working Voltage (indicating circuit)<br />
FH7-1PM30-D1<br />
FH7-1PM30-D2<br />
Leakage Current (indicating circuit)<br />
FH7-1PM30-D1<br />
FH7-1PM30-D2<br />
95…600V AC; 115…600V DC<br />
12…24V DC<br />
35…48V DC<br />
0.8mA max. @ 600V<br />
10mA @ 24V<br />
10mA @ 48V<br />
95…600V AC; 115…600V DC<br />
~<br />
~<br />
0.8mA max. @ 600V<br />
~<br />
~<br />
35.00<br />
52.20<br />
17.00<br />
26.00<br />
1.15<br />
4.35<br />
95…600V AC; 115…600V DC<br />
~<br />
~<br />
0.8mA max. @ 600V<br />
~<br />
~<br />
Withstand Rating 100kA 100kA 100kA<br />
Fuse Type Midget fuses only ➊ Midget fuses only ➊ Midget fuses only ➊<br />
Temperature Range –40°…+221°F (–40°…+105°C) –40°…+221°F (–40°…+105°C) –40°…+221°F (–40°…+105°C)<br />
Common Midget Fuse Applications<br />
• Transformer secondary protection<br />
• Supplemental protection of:<br />
- Control circuits<br />
- Lighting<br />
- Solenoids<br />
3.07" (78mm)<br />
3.07" (78mm)<br />
Typical Midget Fuse Dimensions<br />
3.07" (78mm)<br />
Pkg<br />
Qty<br />
2<br />
2<br />
12<br />
12<br />
50<br />
10<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />
FH7<br />
➊ Fuses not offered by Sprecher + Schuh.<br />
M34<br />
Discount Schedule B-7
R R R<br />
Series FH7 Fuse Holders<br />
For Class CC Fuses<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />
DIN-rail Mounted Fuse Holders – Class CC Fuses ➊<br />
Ordering and<br />
Technical<br />
Information<br />
Fuse Block -<br />
Without Blown Fuse LED<br />
With Blown Fuse LED<br />
DIN-rail<br />
Top Hat, low profile (priced per rail)<br />
Top Hat, high profile (priced per rail)<br />
End Anchors<br />
DIN Rail — Normal Duty<br />
DIN Rail — Heavy Duty<br />
Catalog Number<br />
FH7-1PC30<br />
FH7-1PC30-L<br />
3F<br />
3AF<br />
V7-EA35<br />
V7-EAH35<br />
One Pole<br />
2.13"<br />
0.69" (17.5mm) (54mm)<br />
Price Ea.<br />
(Std Pkg)<br />
10.70<br />
16.10<br />
17.00<br />
26.00<br />
1.15<br />
4.35<br />
Pkg<br />
Qty<br />
6<br />
6<br />
Catalog Number<br />
FH7-2PC30<br />
FH7-2PC30-L<br />
Accessories<br />
12<br />
12<br />
50<br />
10<br />
3F<br />
3AF<br />
V7-EA35<br />
V7-EAH35<br />
Two Pole<br />
2.13"<br />
1.38" (35mm) (54mm)<br />
Price Ea.<br />
(Std Pkg)<br />
23.10<br />
34.30<br />
17.00<br />
26.00<br />
1.15<br />
4.35<br />
Pkg<br />
Qty<br />
3<br />
3<br />
12<br />
12<br />
50<br />
10<br />
Catalog Number<br />
FH7-3PC30<br />
FH7-3PC30-L<br />
3F<br />
3AF<br />
V7-EA35<br />
V7-EAH35<br />
Three Pole<br />
2.13"<br />
2.07" (52mm) (54mm)<br />
Price Ea.<br />
(Std Pkg)<br />
Fuse Block Specifications<br />
Approvals<br />
Voltage Rating 600V AC/DC 600V AC/DC 600V AC/DC 600V AC/DC 600V AC/DC 600V AC/DC<br />
Maximum Current 30 A 30 A 30 A 30 A 30 A 30 A<br />
Wire Range (Rated Cross Section) #14–#6 AWG<br />
2.5…16mm 2<br />
#14–#6 AWG<br />
2.5…16mm 2<br />
#14–#6 AWG<br />
2.5…16mm 2<br />
#14–#6 AWG<br />
2.5…16mm 2<br />
#14–#6 AWG<br />
2.5…16mm 2<br />
#14–#6 AWG<br />
2.5…16mm 2<br />
Wire Strip Length 0.5" (12.7 mm) 0.5" (12.7 mm) 0.5" (12.7 mm)<br />
Recommended Tightening Torque 15 lb-in. (1.7 Nm) 15 lb-in. (1.7 Nm) 15 lb-in. (1.7 Nm)<br />
Working Voltage (indicating circuit) 95…600V AC; 115…600V DC 95…600V AC; 115…600V DC 95…600V AC; 115…600V DC<br />
Leakage Current (indicating circuit) 0.8mA max. @ 600V 0.8mA max. @ 600V 0.8mA max. @ 600V<br />
Withstand Rating 200kA 200kA 200kA<br />
Fuse Type Class CC fuses only ➊ Class CC fuses only ➊ Class CC fuses only ➊<br />
Temperature Range –40°…+221°F (–40°…+105°C) –40°…+221°F (–40°…+105°C) –40°…+221°F (–40°…+105°C)<br />
Common Class CC Applications<br />
• Control transformer protection<br />
• <strong>Motor</strong> circuits<br />
• Branch circuit protection<br />
• Lighting loads<br />
• General purpose loads<br />
• Heating loads<br />
3.07" (78mm)<br />
3.07" (78mm)<br />
Typical Class CC Fuse Dimensions<br />
3.07" (78mm)<br />
34.90<br />
52.00<br />
17.00<br />
26.00<br />
1.15<br />
4.35<br />
Pkg<br />
Qty<br />
2<br />
2<br />
12<br />
12<br />
50<br />
10<br />
M<br />
<strong>Circuit</strong><br />
Protection<br />
➊ Fuses not offered by Sprecher + Schuh.<br />
FH7<br />
Discount Schedule B-7<br />
M35
R R R<br />
Series FH7 Fuse Holders<br />
For Class J Fuses, 30A<br />
M<br />
<strong>Circuit</strong><br />
Protection<br />
DIN-rail Mounted Fuse Holders – Class J Fuses, 30A ➊<br />
Ordering and<br />
Technical<br />
Information<br />
Fuse Block -<br />
Without Blown Fuse LED<br />
With Blown Fuse LED<br />
DIN-rail<br />
Top Hat, low profile (priced per rail)<br />
Top Hat, high profile (priced per rail)<br />
End Anchors<br />
DIN Rail — Normal Duty<br />
DIN Rail — Heavy Duty<br />
4.41" (112mm)<br />
Catalog Number<br />
FH7-1PJ30<br />
FH7-1PJ30-L<br />
3F<br />
3AF<br />
V7-EA35<br />
V7-EAH35<br />
One Pole<br />
2.59"<br />
1.48" (37.5mm) (73.5mm)<br />
Price Ea.<br />
(Std Pkg)<br />
23.40<br />
27.30<br />
17.00<br />
26.00<br />
1.15<br />
4.35<br />
Pkg<br />
Qty<br />
6<br />
6<br />
Catalog Number<br />
FH7-2PJ30<br />
FH7-2PJ30-L<br />
Accessories<br />
12<br />
12<br />
50<br />
10<br />
3F<br />
3AF<br />
V7-EA35<br />
V7-EAH35<br />
Two Pole<br />
2.89"<br />
2.56" (65mm) (73.5mm)<br />
Price Ea.<br />
(Std Pkg)<br />
48.50<br />
56.00<br />
17.00<br />
26.00<br />
1.15<br />
4.35<br />
Pkg<br />
Qty<br />
3<br />
3<br />
12<br />
12<br />
50<br />
10<br />
Catalog Number<br />
FH7-3PJ30<br />
FH7-3PJ30-L<br />
3F<br />
3AF<br />
V7-EA35<br />
V7-EAH35<br />
Three Pole<br />
2.89"<br />
3.86" (98mm) (73.5mm)<br />
Price Ea.<br />
(Std Pkg)<br />
Fuse Block Specifications<br />
Approvals<br />
Voltage Rating 600V AC/DC 600V AC/DC 600V AC/DC 600V AC/DC 600V AC/DC 600V AC/DC<br />
Maximum Current 30 A 30 A 30 A 30 A 30 A 30 A<br />
Wire Range (Rated Cross Section) #14–#6 AWG<br />
2.5…16mm 2<br />
#14–#6 AWG<br />
2.5…16mm 2<br />
#14–#6 AWG<br />
2.5…16mm 2<br />
#14–#6 AWG<br />
2.5…16mm 2<br />
#14–#6 AWG<br />
2.5…16mm 2<br />
#14–#6 AWG<br />
2.5…16mm 2<br />
Wire Strip Length 0.5" (12.7 mm) 0.5" (12.7 mm) 0.5" (12.7 mm)<br />
Recommended Tightening Torque 35 lb-in. (3.95 Nm) 35 lb-in. (3.95 Nm) 35 lb-in. (3.95 Nm)<br />
Working Voltage (indicating circuit) 95…600V AC; 115…600V DC 95…600V AC; 115…600V DC 95…600V AC; 115…600V DC<br />
Leakage Current (indicating circuit) 0.8mA max. @ 600V 0.8mA max. @ 600V 0.8mA max. @ 600V<br />
Withstand Rating 200kA 200kA 200kA<br />
Fuse Type Class J fuses only ➊ Class J fuses only ➊ Class J fuses only ➊<br />
Temperature Range –40°…+221°F (–40°…+105°C) –40°…+221°F (–40°…+105°C) –40°…+221°F (–40°…+105°C)<br />
Common Class J Applications<br />
• <strong>Motor</strong> circuits<br />
• Feeders and mains<br />
• Branch circuit protection<br />
• Lighting, heating and general loads<br />
• Power transformers<br />
• Control transformers<br />
• Control circuits<br />
4.41" (112mm)<br />
4.41" (112mm)<br />
Typical Class J (1-30A) Fuse Dimensions<br />
72.80<br />
83.90<br />
17.00<br />
26.00<br />
1.15<br />
4.35<br />
Pkg<br />
Qty<br />
2<br />
2<br />
12<br />
12<br />
50<br />
10<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />
FH7<br />
➊ Fuses not offered by Sprecher + Schuh.<br />
M36<br />
Discount Schedule B-7
R R R<br />
Series FH7 Fuse Holders<br />
For Class J Fuses, 60A<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />
DIN-rail Mounted Fuse Holders – Class J Fuses, 60A ➊<br />
Ordering and<br />
Technical<br />
Information<br />
Fuse Block -<br />
Without Blown Fuse LED<br />
With Blown Fuse LED<br />
DIN-rail<br />
Top Hat, low profile (priced per rail)<br />
Top Hat, high profile (priced per rail)<br />
End Anchors<br />
DIN Rail — Normal Duty<br />
DIN Rail — Heavy Duty<br />
4.80" (122mm)<br />
Catalog Number<br />
FH7-1PJ60<br />
FH7-1PJ60-L<br />
3F<br />
3AF<br />
V7-EA35<br />
V7-EAH35<br />
One Pole<br />
3.23"<br />
1.57" (40mm) (82mm)<br />
Price Ea.<br />
(Std Pkg)<br />
26.70<br />
30.30<br />
17.00<br />
26.00<br />
1.15<br />
4.35<br />
Pkg<br />
Qty<br />
6<br />
6<br />
Catalog Number<br />
FH7-2PJ60<br />
FH7-2PJ60-L<br />
Accessories<br />
12<br />
12<br />
50<br />
10<br />
3F<br />
3AF<br />
V7-EA35<br />
V7-EAH35<br />
Two Pole<br />
3.23"<br />
3.15" (80mm) (82mm)<br />
Price Ea.<br />
(Std Pkg)<br />
54.90<br />
62.30<br />
17.00<br />
26.00<br />
1.15<br />
4.35<br />
Pkg<br />
Qty<br />
3<br />
3<br />
12<br />
12<br />
50<br />
10<br />
Catalog Number<br />
FH7-3PJ60<br />
FH7-3PJ60-L<br />
3F<br />
3AF<br />
V7-EA35<br />
V7-EAH35<br />
Three Pole<br />
3.23"<br />
4.72" (120mm) (82mm)<br />
Price Ea.<br />
(Std Pkg)<br />
Fuse Block Specifications<br />
Approvals<br />
Voltage Rating 600V AC/DC 600V AC/DC 600V AC/DC 600V AC/DC 600V AC/DC 600V AC/DC<br />
Maximum Current 60 A 60 A 60 A 60 A 60 A 60 A<br />
Wire Range (Rated Cross Section) #14–#6 AWG<br />
2.5…16mm 2<br />
#14–#6 AWG<br />
2.5…16mm 2<br />
#14–#6 AWG<br />
2.5…16mm 2<br />
#14–#6 AWG<br />
2.5…16mm 2<br />
#14–#6 AWG<br />
2.5…16mm 2<br />
#14–#6 AWG<br />
2.5…16mm 2<br />
Wire Strip Length 0.5" (12.7 mm) 0.5" (12.7 mm) 0.5" (12.7 mm)<br />
Recommended Tightening Torque 45 lb-in. (5.0 Nm) 45 lb-in. (5.0 Nm) 45 lb-in. (5.0 Nm)<br />
Working Voltage (indicating circuit) 95…600V AC; 115…600V DC 95…600V AC; 115…600V DC 95…600V AC; 115…600V DC<br />
Leakage Current (indicating circuit) 0.8mA max. @ 600V 0.8mA max. @ 600V 0.8mA max. @ 600V<br />
Withstand Rating 200kA 200kA 200kA<br />
Fuse Type Class J fuses only ➊ Class J fuses only ➊ Class J fuses only ➊<br />
Temperature Range –40°…+221°F (–40°…+105°C) –40°…+221°F (–40°…+105°C) –40°…+221°F (–40°…+105°C)<br />
Common Class J Applications<br />
• <strong>Motor</strong> circuits<br />
• Feeders and mains<br />
• Branch circuit protection<br />
• Lighting, heating and general loads<br />
• Power transformers<br />
• Control transformers<br />
• Control circuits<br />
4.80" (122mm)<br />
4.80" (122mm)<br />
Typical Class J (31-60A) Fuse Dimensions<br />
82.30<br />
93.50<br />
17.00<br />
26.00<br />
1.15<br />
4.35<br />
Pkg<br />
Qty<br />
2<br />
2<br />
12<br />
12<br />
50<br />
10<br />
M<br />
<strong>Circuit</strong><br />
Protection<br />
➊ Fuses not offered by Sprecher + Schuh.<br />
FH7<br />
Discount Schedule B-7<br />
M37
Fuse Block Selection Guide<br />
Series FH7 Fuse Holders<br />
M<br />
<strong>Circuit</strong><br />
Protection<br />
FH7<br />
Control Transformers - Primary ➊<br />
Transformer Max.<br />
Value<br />
Fuse<br />
Block<br />
Max.<br />
Value<br />
Fuse<br />
Block<br />
Max.<br />
Value<br />
Fuse<br />
Block<br />
Max.<br />
Value<br />
Fuse<br />
Block<br />
VA 208V 240V 480 575V<br />
50 1.125 30A 1.0 30A 0.5 30A 0.4 30A<br />
100 2.25 30A 2.0 30A 1.0 30A 0.6 30A<br />
150 3.5 30A 3.0 30A 1.5 30A 1.25 30A<br />
200 4.5 30A 4.0 30A 2.0 30A 1.6 30A<br />
250 6.0 30A 5.0 30A 2.5 30A 2.0 30A<br />
300 7.0 30A 6.25 30A 3.0 30A 2.5 30A<br />
500 6.0 30A 5.0 30A 5.0 30A 4.0 30A<br />
1000 12.0 30A 10.0 30A 5.0 30A 8.0 30A<br />
1500 17.5 30A 15.0 30A 7.5 30A 6.25 30A<br />
2000 20.0 30A 20.0 30A 10.0 30A 8.0 30A<br />
3000 35.0 60A 30.0 60A 15.0 30A 12.0 30A<br />
5000 60.0 60A 50.0 60A 25.0 30A 20.0 30A<br />
7500 ~ ~ ~ ~ 35.0 60A 30.0 60A<br />
10000 ~ ~ ~ ~ 50.0 60A 40.0 60A<br />
Control Transformers - Secondary<br />
Transformer Max.<br />
Value<br />
Fuse<br />
Block<br />
Max.<br />
Value<br />
Fuse<br />
Block<br />
VA 24V 120V<br />
50 3.2 30A 0.6 30A<br />
100 6.25 30A 1.25 30A<br />
150 10.0 30A 2.0 30A<br />
200 12.0 30A 2.5 30A<br />
250 15.0 30A 3.2 30A<br />
300 20.0 30A 4.0 30A<br />
500 30.0 30A 6.25 30A<br />
1000 60.0 60A 12.0 30A<br />
1500 ~ ~ 17.5 30A<br />
2000 ~ ~ 25.0 30A<br />
3000 ~ ~ 35.0 60A<br />
5000 ~ ~ 60.0 60A<br />
7500 ~ ~ ~ ~<br />
10000 ~ ~ ~ ~<br />
➊ Class CC and Class J fuses may be used for Primary Protection,<br />
contact fuse manufacturer for specific use.<br />
The Maximum Values listed in the tables are calculated from the following<br />
procedures, which can be found in the NEC . Always compute the Max.<br />
Value for your specific application prior to selecting a fuse block.<br />
Calculating NEC Maximum Values<br />
Selecting the proper fuse block current ratings for the primary and secondary protection<br />
of control transformers (per UL/NEC) is as follows:<br />
Primary Overcurrent Protection for Control Transformers<br />
Control <strong>Circuit</strong>s: If the rated primary current is less than 2 amps, the maximum<br />
rating of the overcurrent device is 500%. If the rated primary current is<br />
more than 2 amps, the maximum rating of the overcurrent device is 250%.<br />
Secondary Overcurrent Protection for Control Transformers<br />
Control <strong>Circuit</strong>s: If the rated secondary current is less than 9 amps, the<br />
maximum rating of the overcurrent device is 167%. If 9 amps or more, the<br />
maximum rating of the overcurrent device is 125%. The next larger size of an<br />
overcurrent device may be used if 125% does not correspond to a standard<br />
size.<br />
Reference: UL 508 19.3, NEC 430-72(c) exception No. 2, 450-3(b) 1 & 2<br />
Primary Fuse Block Selection Example:<br />
1000VA Transformer<br />
480V Primary<br />
1000/480 = 2.08 Amps [May increase by 250% if above 2A]<br />
2.08 x 250% = 5.21 Amps<br />
Select 30A FH7 Class CC fuse block for 5A Class CC Fuse<br />
Secondary Fuse Block Selection Example:<br />
5000VA Transformer<br />
120V Secondary<br />
5000/120 = 41.7 Amps [May increase by 125% if above 9A]<br />
41.7 x 125% = 52.1 Amps<br />
Select 60A FH7 Class J fuse block for 50A Class J Fuse<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />
M38<br />
Discount Schedule B-7
Fuse Block Selection Guide<br />
Series FH7 Fuse Holders<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />
Three Phase <strong>Motor</strong> Loads ➊➋➌<br />
Horsepower<br />
FLA<br />
Fuse<br />
Block<br />
FLA<br />
Fuse<br />
Block<br />
FLA<br />
Fuse<br />
Block<br />
FLA<br />
208V 240V 480V 575V<br />
Fuse<br />
Block<br />
1/2 2.4 30A 2.2 30A 1.1 30A 0.9 30A<br />
3/4 3.5 30A 3.2 30A 1.6 30A 1.3 30A<br />
1 4.6 30A 4.2 30A 2.1 30A 1.7 30A<br />
1-1/2 6.6 30A 6.0 30A 3.0 30A 2.4 30A<br />
2 7.5 30A 6.8 30A 3.4 30A 2.7 30A<br />
3 10.6 30A 9.6 30A 4.8 30A 3.9 30A<br />
5 16.8 30A 15.2 30A 7.6 30A 6.1 30A<br />
7-1/2 24.2 60A 22.0 60A 11.0 30A 9.0 30A<br />
10 30.8 60A 28.0 60A 14.0 30A 11.0 30A<br />
15 ~ ~ 42.0 60A 21.0 30A 17.0 30A<br />
20 ~ ~ ~ ~ 27 60A 22.0 60A<br />
25 ~ ~ ~ ~ 34 60A 27.0 60A<br />
30 ~ ~ ~ ~ 40 60A 32.0 60A<br />
40 ~ ~ ~ ~ ~ ~ 41.0 60A<br />
Single Phase <strong>Motor</strong> Loads ➊➋➌<br />
Horsepower<br />
FLA<br />
115V<br />
Fuse<br />
Block<br />
FLA<br />
230V<br />
Fuse<br />
Block<br />
1/6 4.4 30A 2.2 30A<br />
1/4 5.8 30A 2.9 30A<br />
1/3 7.2 30A 3.6 30A<br />
1/2 9.8 30A 4.9 30A<br />
3/4 13.8 30A 6.9 30A<br />
1 16 30A 8 30A<br />
1-1/2 20 30A 10 30A<br />
2 24 60A 12 30A<br />
3 34 60A 17 30A<br />
5 ~ ~ 28 60A<br />
7-1/2 ~ ~ 40 60A<br />
10 ~ ~ 50 60A<br />
➊ Fuse block size is based on Class J Type time-delay fuses for typical motor<br />
acceleration up to 5 seconds. Limited use of Class CC fuse blocks may be used for<br />
motor loads, contact fuse manufacturer for acceptance.<br />
➋ FLA Data is in accordance with UL-508 Table 42.2 & NEC Tables 430-148 & 150.<br />
➌ Selection of fuse block should be based on selected fuse manufacturer data.<br />
M<br />
<strong>Circuit</strong><br />
Protection<br />
FH7<br />
Discount Schedule B-7<br />
M39
Series FH7 Fuse Holders<br />
Notes Page<br />
Notes<br />
M<br />
<strong>Circuit</strong><br />
Protection<br />
Sold by <strong>AA</strong> <strong>Electric</strong> 1-800-237-8274 Lakeland, FL • Lawrenceville, GA • Greensboro, NC • East Rutherford, NJ www.A-Aelectric.com<br />
FH7<br />
M40<br />
Discount Schedule B-7