Leak Detective II Leak Detector<br />

Affordable <strong>the</strong>rmal conductivity leak detector—every analyst should have one.<br />

Compact, ergonomic design is easy to hold and operate.<br />

Detects helium, hydrogen, and nitrogen at 1x10 -4 cc/sec. or at an absolute concentration<br />

as low as 100ppm.*<br />

Fast results—responds in less than 2 seconds to trace leaks <strong>of</strong> gases with <strong>the</strong>rmal conductivities<br />

different than air.<br />

Microchip design improves sensitivity and response time over previous models.<br />

Auto zeroing with <strong>the</strong> touch <strong>of</strong> a button.<br />

Battery-operated for increased portability (one 9-volt).<br />

The compact, affordable tool that every analyst should have!<br />

Description qty. cat.#<br />

Leak Detective II Leak Detector ea. 20413<br />

*Never use liquid leak detectors on a capillary system because liquids can be drawn into <strong>the</strong> column.<br />

Caution: NOT designed for determining leaks <strong>of</strong> combustible gases. A combustible gas detector should<br />

be used for determining combustible gas leaks in possible hazardous conditions.<br />

Pre-Cleaned <strong>Volatile</strong> <strong>Organic</strong> Analyte Sampling Vials<br />

Container, liner and closure cleaned and assembled.<br />

Clear or amber.<br />

Open top caps.<br />

PTFE<br />

faced 0.125" silicone septa.<br />

Each case lot numbered.<br />

Description qty. cat.#<br />

20mL Clear Pre-Cleaned VOA Vials 72-pk. 21798<br />

20mL Amber Pre-Cleaned VOA Vials 72-pk. 21799<br />

40mL Clear Pre-Cleaned VOA Vials 72-pk. 21796<br />

40mL Amber Pre-Cleaned VOA Vials 72-pk. 21797<br />

1mm ID Liners<br />

for Agilent/Finnigan GCs<br />

1mm Split<br />

for Varian GCs<br />

1mm Split<br />

for Shimadzu GCs<br />

17A 1mm Split<br />

PSS Liners for PerkinElmer GCs<br />

PSS Split/Splitless (1mm ID)<br />

for Thermo Finnigan 8000 & TRACE Series GCs<br />

1mm Split<br />

ID*/OD &<br />

Length (mm)<br />

1.0 ID<br />

4.0 OD x 86.2<br />

ID**/OD &<br />

Length (mm)<br />

ID**/OD &<br />

Length (mm)<br />

Similar to<br />

PE part #<br />

ID**/OD &<br />

Length (mm)<br />

cat.#<br />

ea.<br />

cat.#<br />

ea.<br />

cat.#<br />

5-pk.<br />

cat.#<br />

5-pk.<br />

1.0 ID<br />

6.3 OD x 78.5 20972 20973<br />

ID**/OD &<br />

Length (mm)<br />

cat.#<br />

ea.<br />

cat.#<br />

5-pk.<br />

cat.#<br />

25-pk.<br />

1.0 ID<br />

5.0 OD x 95 20976 20977 20978<br />

cat.#<br />

25-pk.<br />

N612-1006 20738 20741 —<br />

Similar to<br />

TF Part #<br />

cat.#<br />

ea.<br />

cat.#<br />

ea.<br />

cat.#<br />

5-pk.<br />

1.0 ID<br />

6.3 OD x 72 20970 20971<br />

cat.#<br />

5-pk.<br />

1.0 ID<br />

8.0 OD x 105 453 20075 20916 20917<br />

all liners are<br />

10 0%<br />

deactivated<br />

65<br />

We deactivate Restek liners using our<br />

unique polymeric deactivation process to<br />

ensure accurate chromatographic data. We<br />

evaluate <strong>the</strong>m with an endrin breakdown<br />

test for complete inertness, and each liner<br />

is dimensionally checked for a perfect fit.<br />

Siltek and base deactivation are available<br />

for specialized analyses<br />