01.11.2012 Views

Optimizing the Analysis of Volatile Organic Compounds

Optimizing the Analysis of Volatile Organic Compounds

Optimizing the Analysis of Volatile Organic Compounds

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

64<br />

www.restekcorp.com<br />

MXT ® -Union Connector Kits—For Fused Silica Columns<br />

Low-dead-volume, leak-free connection.<br />

Reusable.<br />

Silcosteel ® treatment ensures maximum inertness.<br />

Ideal for connecting a guard column or transfer line to an analytical column.<br />

Use to oven temperatures <strong>of</strong> 350°C.<br />

Available in union and “Y” configurations.<br />

Each kit contains <strong>the</strong> MXT ® union, two 1/32-inch nuts and two one-piece fused silica<br />

adaptors.<br />

Description qty. cat.#<br />

For 0.25mm ID Fused Silica Columns<br />

kit<br />

21386<br />

For 0.32mm ID Fused Silica Columns kit 21385<br />

For 0.53mm ID Fused Silica Columns kit 21384<br />

Valco ® Connectors—One-Piece Fused Silica Adaptor Ferrule<br />

For connecting fused silica or 1/16- or 1/8-inch metal tubing.<br />

Use with Mxt ® -Union Connectors<br />

Use to oven temperature <strong>of</strong> 350°C<br />

Made from graphite-reinforced polyimide<br />

1/32-Inch Adaptor Ferrule<br />

Tubing OD Tubing ID Valco<br />

Valcon Polyimide<br />

0.25–0.4mm 0.25mm<br />

FS.4-5<br />

5-pk.<br />

20137<br />

® # qty. cat.#<br />

0.4–0.5mm 0.32mm FS.5-5 5-pk. 20140<br />

0.5–0.8mm 0.53mm ZF.5V-5 5-pk. 20141<br />

1<br />

/32" Replacement Nut 5-pk. 20389<br />

Heavy Duty Purge & Trap Syringe (Dynatech Precision Sampling)<br />

Heavy-duty glass barrel with metal front and rear flanges.<br />

Luer-Lock tip.<br />

Can fill and empty sparge tubes.<br />

Accepts standard Luer-Lock ® ®<br />

PTFE<br />

needles.<br />

2mL 5mL 10mL<br />

Syringe cat.# cat.# cat.#<br />

without Sample-Lok 21205 21206 21209<br />

with Sample-Lok — 21208 21207<br />

PTFE Tip, Gas-Tight Syringe Replacement<br />

Needles for Luer-Lock Syringes<br />

Hub Needle Needle Point SGE Restek<br />

Material Gauge Length Style cat.# qty. cat.#<br />

metal 23 50mm 2 039802 5-pk. 24763<br />

metal 22 2"/51mm 3 039895** 2-pk. 24765<br />

metal 18 50mm 2 039842 5-pk. 24764<br />

**For Rheodyne ® /Valco ® valves.