01.11.2012 Views

Optimizing the Analysis of Volatile Organic Compounds

Optimizing the Analysis of Volatile Organic Compounds

Optimizing the Analysis of Volatile Organic Compounds

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Siltek -Deactivated Guard Columns/Transfer Lines<br />

Revolutionary deactivation process lowers endrin breakdown to less than 1%.<br />

Minimize bleed.<br />

Ideal for chlorinated pesticide analysis.<br />

Analyze tough samples quickly and accurately.<br />

Maximum temperature <strong>of</strong> 380°C.<br />

Reduces effects <strong>of</strong> dirty samples on column performance.<br />

Reduces downtime and maintenance.<br />

Ordering Information | Siltek -Deactivated Guard Columns<br />

Nominal ID Nominal OD 5-Meter<br />

0.32mm 0.45 ± 0.04mm 10027<br />

0.53mm 0.69 ± 0.05mm 10028<br />

Low-Volume Injector for Agilent 5890 Septum Packed Purge Port<br />

Allows syringe injections onto <strong>the</strong> column for purge & trap troubleshooting or<br />

calibration.<br />

Silcosteel ® treatment eliminates adsorption <strong>of</strong> active compounds.<br />

Attaches to GC inlet without cutting injection port lines.<br />

Everything you need for installation is provided, including a 1 /16-inch nut, a 1 /16-inch ferrule,<br />

a base nut and 1 /4-inch Vespel ® /graphite ferrule, a 1 /16-inch capillary nut, a 5-pack <strong>of</strong> lowbleed<br />

plug septa, and a special low-mass septum nut. Order appropriate capillary ferrules<br />

separately—see our catalog.<br />

Description qty. cat.#<br />

Low-Volume Injector for Agilent 5890 Septum Packed Purge Port kit 21698<br />

Low-Volume Injector for Agilent GCs<br />

Fits Agilent split/splitless injectors.<br />

Attaches to <strong>the</strong> GC inlet without cutting existing injection port lines.<br />

Allows injections from a syringe onto <strong>the</strong> column for purge & trap troubleshooting<br />

or calibration.<br />

Silcosteel ® treatment eliminates adsorption <strong>of</strong> active compounds.<br />

Our low-volume injector can be installed in a matter <strong>of</strong> minutes. Remove <strong>the</strong> septum nut or<br />

splitless weldment and insert <strong>the</strong> Restek low-volume injector through <strong>the</strong> split injector.<br />

Tighten <strong>the</strong> base nut and you’re ready! Includes a 1 /16-inch nut, a 1 /16-inch ferrule, a base nut<br />

and 1 /4-inch Vespel ® /graphite ferrule, a 1 /16-inch capillary nut, a 5-pack <strong>of</strong> low-bleed plug<br />

septa, and a low-mass septum nut. Order appropriate capillary ferrules separately—see our<br />

catalog.<br />

Description qty. cat.#<br />

Low-Volume Injector for Agilent Split/Splitless GC Inlets kit 21692<br />

Low-Volume Injector for Varian Split/Splitless Inlets<br />

Attaches to <strong>the</strong> GC inlet without cutting existing injection port lines.<br />

Allows injections from a syringe onto <strong>the</strong> column for purge & trap troubleshooting or<br />

calibration.<br />

Silcosteel ® treatment eliminates adsorption <strong>of</strong> active compounds.<br />

Order capillary ferrules separately—see our catalog.<br />

Description qty. cat.#<br />

Low-Volume Injector for Varian Split/Splitless GC Inlets kit 21693<br />

63<br />

www.restekcorp.com

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!