62<br />

www.restekcorp.com<br />

Rtx ® -502.2<br />

Recommended for <strong>the</strong> analysis <strong>of</strong> volatile organic compounds (VOCs) in EPA Methods.<br />

Specified in many GRO methods for monitoring leaking underground storage tanks.<br />

Crossbond ® technology. Reduced bleed, Increased column lifetime, Solvent rinsability.<br />

Similar to DB-502.2 columns.<br />

Ordering Information | Rtx ® -502.2 (Fused Silica)<br />

(EPA <strong>Volatile</strong>s in Methods 502.2, 524.2)<br />

ID df (µm) temp. limits 30-Meter 60-Meter 75-Meter 105-Meter<br />

0.25mm 1.40 -20 to 250/270°C 10915 10916<br />

0.45mm 2.55 -20 to 250/270°C 10986<br />

0.53mm 3.00 -20 to 250/270°C 10908 10909 10910<br />

ID df (µm) temp. limits 20-Meter 40-Meter<br />

0.18mm 1.00 -20 to 250/270°C 40914 40915<br />

Ordering Information | Rtx ® Rtx<br />

-<strong>Volatile</strong>s (Fused Silica)<br />

(EPA <strong>Volatile</strong> <strong>Organic</strong> Methods)<br />

*The maximum temperatures listed are for 15- and 30-meter lengths.<br />

Longer lengths may have a slightly reduced maximum temperature.<br />

® -<strong>Volatile</strong>s<br />

Analyze volatile organic compounds (VOCs) in EPA methods.<br />

Crossbond ® technology.<br />

280°C <strong>the</strong>rmal stability.<br />

Similar to VOCOL ® columns.<br />

ID df (µm) temp. limits* 30-Meter 60-Meter 105-Meter<br />

0.25mm 1.00 -20 to 270/280°C 10900 10903<br />

0.53mm 2.00 -20 to 270/280°C 10902 10905 10906<br />

Rtx ® -1<br />

Ideal for analysis <strong>of</strong> solvents and petrochemicals.<br />

Available in unbreakable Silcosteel ® (MXT ® ) tubing.<br />

Thermally stable to 350°C (MXT ® stable to 400°C).<br />

Similar to DB-1, SPB-1, HP-1, and Ultra-1 phases.<br />

Ordering Information | Rtx ® -1 (Fused Silica)<br />

(Crossbond ® 100% dimethyl polysiloxane)<br />

ID df (µm) temp. limits 75-Meter 105-Meter<br />

0.45mm 2.55 -60 to 270/290°C 10992<br />

0.53mm 3.00 -60 to 270/290°C 10189<br />

The maximum temperatures listed are for 15- and 30-meter lengths.<br />

Longer lengths may have a slightly reduced maximum temperature.<br />

Intermediate-Polarity Deactivated Guard Columns & Transfer Lines<br />

Useful for a wide range <strong>of</strong> applications.<br />

Use with most common solvents.<br />

Maximum temperature: 325°C<br />

Reduce effects <strong>of</strong> dirty samples on column performance.<br />

Reduce downtime and maintenance.<br />

Ordering Information | Fused Silica<br />

Nominal ID Nominal OD 5-Meter 5-Meter/6-pk.<br />

0.32mm 0.45 ± 0.04mm 10044 10044-600<br />

0.53mm 0.69 ± 0.05mm 10045 10045-600<br />

Ordering Information | MXT ® (Silcosteel ® )<br />

Nominal ID Nominal OD 5-Meter 5-Meter/6-pk. 10-Meter<br />

0.53mm 0.74 ± 0.025mm 70045 70045-600 70047<br />

* Not tested with <strong>the</strong> Grob test mix because <strong>of</strong> a large pressure drop.<br />

** 30- and 60-meter lengths are banded in 5-meter sections.