Peripheral Units<br />

Plus Distributor 6<br />

Professional fuse protection of separate electric circuits at the plus side of the battery avoiding fire on cables and vehicles.<br />

The plus feed line serving for plus distribution is to be connected to the two-pole terminal screw (2 x 6 mm²) . Thus, 6 fuseprotected<br />

positive electric circuit connections with a large clamping range (4 mm², max. 16 A) are obtained. The electric<br />

circuits are marked with 1-6.<br />

The delivery includes 12 V / 24 V flat plug fuse 4x 8 A, 1 x 10 A and 1 x 15 A. Suitable for 12 V and 24 V operation.<br />

Execution A<br />

Minus Distributor 12<br />

Professional junction of 12 separate electric circuits at the minus side of the battery. Particularly recommendable for gro<strong>und</strong><br />

distribution in case of insulating (plastic) vehicle bodies. The minus feed line serving for minus distribution is to be connected<br />

to the two-pole terminal screw (2 x 6 mm²). Thus, 12 negative electric circuit connections with a large clamping range<br />

(4 mm², max. 16 A) are obtained. The electric circuits are marked with 1-12. Suitable for 12 V and 24 V operation.<br />

Execution B<br />

Plus Distributor 8<br />

Efficient plus distributor with 6 fuse-protected outputs of different capacity values. The plus feed line of the battery is connected<br />

to a solid terminal block with cable lug (16 mm²). The distribution is the following:<br />

Connection 1: Terminal block with cable lug (16 mm²) and strip fuse 40 A, 50 A or 60 A, with light-emitting diode indicator,<br />

as main protection, or for larger consumers, such as inverters up to 12 V/600 W or 24 V/1200 W, powerful chargers etc.<br />

Connection 2: Terminal 6 mm² with flat plug fuse 30 A, such as for average consumers or charger. This branch can either<br />

be supplied by the main circuit by means of an internal bridge, or separately from the other circuits over a second terminal<br />

6 mm².<br />

Connections 3 - 6: Terminals with large clamping range (4 mm² max. 16 A) and flat plug fuses 2 x 15 A and 2 x 10 A.<br />

The cover with cable guiding unit ensures safe fixing of the cables and neat appearance. The light-emitting diode for supervision<br />

of the strip fuse connection 1is also visible with the cover is installed. The plug-in type fuses are identified by labels.<br />

Suitable for 12 V and 24 V operation.<br />

Execution C<br />

Minus Distributor 14<br />

Efficient distributor at the minus side of the battery for 12 individual electric circuits. Particularly recommendable for gro<strong>und</strong><br />

distribution in case of insulating (plastic) vehicle bodies. The minus feed line is connected to a solid terminal block with<br />

cable lug (16 mm²). If required, a further terminal block serves for minus distribution (cable lug 16 mm²). The distribution<br />

is effected on 4 terminals (6 mm², max. 32 A), as well as 8 terminals (4 mm², max. 16 A). The electric circuits are marked<br />

with 1-12. The cover with cable guiding unit ensures safe fixing of the cables and neat appearance. Suitable for 12 V and<br />

24 V operation.<br />

Execution D<br />

Fig. Without Cover<br />

Unit Type Order No. Operating Voltage Dimensions (WxDxH) mm Execution<br />

Plus Distributor 6 3209 12 and 24 47x75x35 A<br />

Minus Distributor 12 3212 12 and 24 47x75x35 B<br />

Plus Distributor 8 1 3215 12 and 24 105x71x36 C<br />

Minus Distributor 14 2 3218 12 and 24 105x71x36 D<br />

Delivery Scope: Manual<br />

Delivery Scope 1 : 2 Pcs. cable lugs, 16 mm², stripe fuse 40 A, 50 A, 60 A,<br />

flat plug fuses 1 x 30 A, 2 x 15 A and 2 x 10 A, manual<br />

Delivery Scope 2 : 2 Pcs. cable lugs, 16 mm², manual<br />

* Dimensions incl. mounting flanges<br />

Fig. Without Cover<br />

37