No. Sr. Mgr(P)/326/10-11/ Squirrel Cage Induction Motor /11 Dated:18.04.2012 (b) To purchase elsewhere, after due notice to the successful tenderer on the account and at the risk of the defaulting supplier the stores not supplied or others of a similar description without canceling the supply order in respect of the consignment not yet due for supply or (c) To cancel the supply order or a portion thereof, and if so desired to purchase the stores at the risk and cost of the defaulting supplier and also (d) To extend the period of delivery with or without penalty as may be considered fit and proper, the penalty, if imposed shall not be more than the agreed Liquidated Damages referred to in clause (a) above. (e) To forfeit the security deposit full or in part. (f) Whenever under this contract a sum of money is recoverable from and payable by the supplier, Central Coalfields Ltd. shall be entitled to recover such sum by appropriating, in part or in whole, by deducting any sum or which at any time thereafter may become due to the successful tenderer in this or any other contract. Should this sum be not sufficient to cover the full amount recoverable, the successful tenderer shall pay Central Coalfields on demand the remaining balance. The supplier shall not be entitled to any gain on any such purchase. 22 . Other terms and conditions of contract will also be governed by the General Terms & Conditions of supply of Stores enclosed with the NIT and also enclosed with this order as Annexure 'IV' and all terms and condition thereof will be applicable unless otherwise specified in this order. The supplier shall warrant that the item(s) supplied under this contract /supply order : a) Is new, unused and or current design not likely to be discontinued or become obsolete in near future . b) Is in accordance with contract specification c) Shall have no defects arising out of design, materials and workmanship. The contract is concluded with this acceptance. We enclose herewith two copies of the Supply order. One copy of the same may please be returned within 7-days from the date of receipt of this order duly signed and stamped on the seal of your company as a token of acceptance and acknowledgement, otherwise, it will be presumed that you have accepted the contract as per terms and conditions stipulated above for execution. Enclosures : 1 .General Terms & Conditions of supply of stores - Annexure 'IV'. Yours faithfully, For & on behalf of CENTRAL COALFIELDS LIMITED ( S.K.Agrawal ) ( N.K.Dutta ) Chief Manager(P) Chief Manager(P) Copy forwarded to:- 1. The GM ( Ws. ) CCL , Ranchi. 2. The GM , CCL, Rajrappa/ Kathara. 4. The Area Finance Manager , CCL, Rajrappa/Kathara: This has been concurred in by Sr.Mgr(F-P) vide conc. No. Sr.Mgr(F-P)/2011-12/264 dtd.07.03.2012 and approved by competent authority. Fund for Rs. 15.14 Lakhs only has been provided / certified vide no. BGT/PP/P&M/Sawang(W)/Rajrappa(W)/CB/12-13/1/111 dtd.10.04.12. 6. The Depot Officer, Regional Stores, Rajrappa Washery/ Sawang Washery. 8. The Project Officer, Rajrappa Washery/ Sawang Washery. 10. The ES to CMD, CCL, Ranchi. 11. The TS to D(T)(P&P) / Secy. to D(T)(O),CCL, Ranchi. 13. Sr.M(F-P) / Sr.M(F-O) / Chief Finance Manager(Hq),CCL,Ranchi. 16. Progress Cell ( M.I.S. ) Cell / Master File / Guard File. : In reference to Ind. Regn. No.326 dated 31.03.2011. 19. ES to CGM(MM) ,CCL,Ranchi. 20. M/s C.M.P.D.I. Ltd., Gondwana Place, Kanke Road, Ranchi-834008. This issues with the approval of the competent authority. Chief Manager(P) Chief Manager(P) :4:

No. Sr. Mgr(P)/326/10-11/ Squirrel Cage Induction Motor /11 Dated:18.04.2012 ANNEXURE-A TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS FOR SQURREL CAGE INDUCTION MOTORS FOR RAJRAPPA(W) AND SAWANG (W) : Sl. No Description Motor‐1 SGW Motor‐2 RRW + SGW Motor‐3 RRW+ SGW Motor‐4 RRW Motor‐5 SGW Motor‐7 RRW 1. Required Quantity 2 4 + 2 = 6 2 + 2 = 4 1 1 2 2. KW 6.3KW 15KW 18.5KW 66 KW 76KW 132 KW 3 Voltage +/‐10% 415V 415V 415V 415V 440V 415V 4. Type Sq.Cage Induction, TEFC 5. RPM at rated load 6. Connected M/C Conveyor belt / vertical pump 7. Drive Direct‐ gear box / V belt Sq.Cage Induction, T E F C Sq.Cage Induction, TEFC Sq.Cage Induction, TEFC Sq.Cage Induction, T E F C Sq.Cage Induction, TEFC 1450 1460 970 1485 1480 1480 Vertical pump/ Conveyor belt V belt Vibrating screen Direct coupled Slurry pump D/R Crusher Slurry pump V belt Direct‐ gear box – V belt 8. Mounting Horizontal/Vertical Vertical/Horizontal Horizontal Horizontal Horizontal Horizontal 9. Max. Ambient Temp V belt 50 deg.C 50 deg.C 50 deg.C 50 deg.C 50 deg.C 50 deg.C 10 Insulation class F F F F F F 11 Frequency +/‐5% 50 50 50 50 50 50 12 No of phases 3 3 3 3 3 3 13 Rated load 28 34.5 116 132 230 current (Amps) 14 Enclosure Non FLP NFLP NFLP NFLP NFLP NFLP 15 Duty condition Continuous Continuous Continuous Continuous Continuous Continuous 16 Type of protection 1P55 1P55 1P55 1P55 1P55 1P55 17 Frame Size Base bolt details enclosed AMW160L4 200L AM280S4 AM 280 MZ4 ADX604S4 Chief Manager(P) Chief Manager(P)

No. Sr. Mgr(P)/326/10-11/ Squirrel Cage Induction Motor /11<br />

Dated:18.04.2012<br />

ANNEXURE-A<br />

TECHNICAL SPECIFICATIONS<br />

TECHNICAL SPECIFICATIONS FOR SQURREL CAGE INDUCTION MOTORS FOR RAJRAPPA(W) AND SAWANG (W) :<br />

Sl. No Description Motor‐1<br />

SGW<br />

Motor‐2<br />

RRW + SGW<br />

Motor‐3<br />

RRW+ SGW<br />

Motor‐4<br />

RRW<br />

Motor‐5<br />

SGW<br />

Motor‐7<br />

RRW<br />

1. Required<br />

Quantity<br />

2 4 + 2 = 6 2 + 2<br />

= 4<br />

1 1 2<br />

2. KW 6.3KW 15KW 18.5KW 66 KW 76KW 132 KW<br />

3 Voltage +/‐10% 415V 415V 415V 415V 440V 415V<br />

4. Type Sq.Cage Induction,<br />

TEFC<br />

5. RPM at rated<br />

load<br />

6. Connected M/C Conveyor belt /<br />

vertical pump<br />

7. Drive Direct‐ gear box /<br />

V belt<br />

Sq.Cage Induction,<br />

T E F C<br />

Sq.Cage<br />

Induction,<br />

TEFC<br />

Sq.Cage<br />

Induction,<br />

TEFC<br />

Sq.Cage<br />

Induction,<br />

T E F C<br />

Sq.Cage<br />

Induction, TEFC<br />

1450 1460 970 1485 1480 1480<br />

Vertical pump/<br />

Conveyor belt<br />

V belt<br />

Vibrating<br />

screen<br />

Direct<br />

coupled<br />

Slurry pump D/R Crusher Slurry pump<br />

V belt<br />

Direct‐ gear<br />

box – V belt<br />

8. Mounting Horizontal/Vertical Vertical/Horizontal Horizontal Horizontal Horizontal Horizontal<br />

9. Max. Ambient<br />

Temp<br />

V belt<br />

50 deg.C 50 deg.C 50 deg.C 50 deg.C 50 deg.C 50 deg.C<br />

10 Insulation class F F F F F F<br />

11 Frequency +/‐5% 50 50 50 50 50 50<br />

12 No of phases 3 3 3 3 3 3<br />

13 Rated load<br />

28 34.5 116 132 230<br />

current (Amps)<br />

14 Enclosure Non FLP NFLP NFLP NFLP NFLP NFLP<br />

15 Duty condition Continuous Continuous Continuous Continuous Continuous Continuous<br />

16 Type of<br />

protection<br />

1P55 1P55 1P55 1P55 1P55 1P55<br />

17 Frame Size Base bolt details<br />

enclosed<br />

AMW160L4 200L AM280S4 AM 280<br />

MZ4<br />

ADX604S4<br />

Chief Manager(P)<br />

Chief Manager(P)