Operating Your <strong>ATEM</strong> Switcher<br />
Performing a Downstream Luma/Linear Key<br />
To set up a luma/linear key on downstream keyer 1 on the software control panel:<br />
Step 1. Select the downstream key 1 palette.<br />
Step 2. Use the drop down controls labeled fill source and key source to specify the fill and key<br />
sources.<br />
If performing a luma key, select the same source for both fill and key.<br />
Step 3. Adjust the key parameters to refine the key.<br />
Downstream Keyer Settings<br />
To set up a luma/linear key on downstream keyer 1 on the broadcast panel:<br />
Step 1. Press the DSK 1 TIE button to enable the downstream keyer on the preview output. The M/E 1<br />
system control will dynamically navigate to the DSK 1 menu. You can manually navigate to the<br />
DSK 1 menu by pressing HOME > DSK KEYS > DSK 1.<br />
Step 2. The destination display will say DSK1 fill on the On the <strong>ATEM</strong> 1 M/E Broadcast Panel. Select the<br />
fill source on the select bus.<br />
Step 3. On the <strong>ATEM</strong> 2 M/E Broadcast Panel, hold down the DEST SHIFT button and select the key<br />
source on the select bus. On the <strong>ATEM</strong> 1 M/E Broadcast Panel, hold down the CUT/FILL button<br />
so the destination display says DSK1 cut and select the key source on the select bus.<br />
If performing a linear key, select the same source for both fill and key.<br />
Step 4. Adjust the clip and gain controls to refine the key or press the pre-mult button for pre-multipled<br />
keys. The clip and gain controls are not available for pre-multipled keys.