Using the <strong>ATEM</strong> 2 M/E Broadcast Panel<br />
However if you need quick access to switch auxiliary outputs using the panel buttons, we suggest assigning<br />
System Control M/E 2 to the <strong>ATEM</strong> 1 M/E Production Switcher. This will let you take advantage of the Aux<br />
buttons which only appear in the 2 M/E block. The <strong>ATEM</strong> Television Studio does not have Aux outputs and<br />
so doesn't use Aux buttons.<br />
If using the default IP settings when using two switchers on the same network, their IP address will initially<br />
be the same, i.e. 192.168.10.240. You should change one of them to 192.168.10.241, or use an IP address<br />
somewhere in the 192.168.10.24_ range to keep all your switchers neatly together. Please follow the steps<br />
detailed in the earlier section "Changing the Switcher Network Settings".<br />
When connecting the <strong>ATEM</strong> 2 M/E Broadcast Panel to two switchers, you need to change the switcher IP<br />
on one of the system control blocks to connect to the switcher whose IP address you have just changed. By<br />
default the System Control M/E 1 block connects to 192.168.10.240 and so you will only need to change the<br />
System Control M/E 2 block if you are using default settings.<br />
To set network location of multiple switchers on the <strong>ATEM</strong> 2 M/E Broadcast Panel, simply follow these steps<br />
for each System Control M/E block:<br />
Step 1. When there is no communication with the switcher, the NETWRK SETUP menu will appear<br />
on the broadcast panel system control. Select the NETWRK SETUP menu button. If there is<br />
communication with a switcher, hold down SHIFT and DEST SHIFT and select the NETWRK<br />
SETUP button.<br />
Step 2.<br />
Step 3.<br />
Select the SWITCHR IP menu button and use the knobs or the numeric keypad to edit each field<br />
as required.<br />
When a field is changed, SAVE and REVERT menu buttons become available. Select SAVE to save<br />
the changed IP address. The system control display will show it is connecting to the switcher and<br />
will display the model of switcher once it has successfully connected.<br />
This does not change the IP address of the switcher itself. It just changes where the control panel is looking<br />
to find the switcher. If the control panel cannot find the switcher, then you might need to check the switcher<br />
processor to see if it's been set correctly. To change the IP address of the switcher, connect the switcher via<br />
USB to a computer and run the <strong>ATEM</strong> Setup Utility software as described previously in this manual.