*******************************************************<br />

Command code => A0h = CARD_RE<strong>SE</strong>T_PARA_CMD<br />

Parameter #1 = > 30h=reset current parameter, 31h=reset all user<br />

--- Answer ---<br />

Parameter #1 = > 30h=reset current parameter, 31h=reset all user<br />

*******************************************************<br />

Command code => A2h = CARD_STORE_RECALL_CMD<br />

Parameter #1 = > 30h=store, 31h=recall<br />

Parameter #2 = > User No.: 31h~33h (3 users)<br />

--- Answer ---<br />

Parameter #1 = > 30h=store, 31h=recall<br />

Parameter #2 = > User No.: 31h~33h (3 users)<br />

Example: Set the CH6’s name to “BKG-2”.<br />

The control data stream: F0h,1Ah,10h,08h,68h,36h,31h,42h,4Bh,47h,2Dh,32h,00h,34h,32h,FFh<br />

F0h,ID(1AH),length(10h),08h,command code(68h),CH No.(36h),on/off(31h),B(42h),K(4Bh),<br />

G(47h),-(2Dh),2(32h),00h,CHECKSUM_L(34h),CHECKSUM_M(32h),FFh<br />

Checksum= F0h+1Ah+10h+08h+68h+36h+31h+42h+4Bh+47h+2Dh+32h+00h=24h<br />

The Answer from <strong>SE</strong><strong>900</strong>’s preview board:<br />

FCh,1Ah,10h,08h,68h,36h,31h,42h,4Bh,47h,2Dh,32h,00h,30h,33h,FFh<br />