*******************************************************<br />

Command code => 98h = <strong>SE</strong>T_ASPECT_RATIO_FLAG_CMD<br />

Parameter #1 = > Set method: 30h=set by parameter #2 directly, 31h=Increase, 32h=Decrease<br />

When (para#1=30h)<br />

Parameter #2 = > Aspect Ratio Flag: 30h= 4:3, 31h =16:9<br />

--- Answer ---<br />

Parameter #1 = > Set method: 30h=set by parameter #2 directly, 31h=Increase, 32h=Decrease<br />

Parameter #2 = > Aspect Ratio Flag: 30h= 4:3, 31h =16:9<br />

*******************************************************<br />

Command code => 99h = ASK_ASPECT_RATIO_FLAG_CMD<br />

Parameter #1 = > NC<br />

--- Answer ----<br />

Parameter #1 = > NC<br />

Parameter #2 = > Aspect Ratio Flag: 30h= 4:3, 31h =16:9<br />

*******************************************************<br />

Command code => 9Ah = <strong>SE</strong>T_DV_OUT_MODE_CMD<br />

Parameter #1 = > Set method: 30h=set by parameter #2 directly, 31h=Increase, 32h=Decrease<br />

When (para#1=30h)<br />

Parameter #2 = > DV output mode: 30h~33h, default=31h<br />

--- Answer ---<br />

Parameter #1 = > Set method: 30h=set by parameter #2 directly, 31h=Increase, 32h=Decrease<br />

Parameter #2 = > DV output mode: 30h~33h<br />

*******************************************************<br />

Command code => 9Bh= ASK_DV_OUT_MODE_CMD<br />

Parameter #1 = > NC<br />

--- Answer ----<br />

Parameter #1 = > NC<br />

Parameter #2 = > DV output mode: 30h~33h<br />

*******************************************************<br />

Command code => A0h = CARD_RE<strong>SE</strong>T_PARA_CMD<br />

Parameter #1 = > 30h=reset current parameter, 31h=reset all user<br />

--- Answer ---<br />

Parameter #1 = > 30h=reset current parameter, 31h=reset all user<br />

*******************************************************<br />

Command code => A2h = CARD_STORE_RECALL_CMD<br />

Parameter #1 = > 30h=store, 31h=recall<br />

Parameter #2 = > User No.: 31h~33h (3 users)<br />

--- Answer ---<br />

Parameter #1 = > 30h=store, 31h=recall<br />

Parameter #2 = > User No.: 31h~33h (3 users)<br />