5.2.6 Analog Video output & DV output Board Command<br />
*******************************************************<br />
Command code => 61h = ASK_CARD_TYPE_CMD<br />
Parameter #1 = >NC<br />
--- Answer ---<br />
Parameter #1 =>38h=Analog & DV OUT,<br />
*******************************************************<br />
Command code => 63h = ASK_WORK_STATUS_CMD<br />
Parameter #1 = > NC<br />
--- Answer ---<br />
Parameter #1 = > Card Type: 30h~40h. (Ref. to command 61h)<br />
Parameter #2 = > Status flag: (b0=0=off, 1=on); (b1=0=NTSC, 1=PAL);<br />
Parameter #3 = >Output mode: normal=30h<br />
Parameter #4 = > 7.5IRE: 30h=off, 31h=on<br />
Parameter #5 = > Analog Color Bar: 30h=off (normal)<br />
Parameter #6 = > DV Output Mode: 30h~33h, default=31h<br />
Parameter #7 = > Aspect Ratio: 30h=4:3, 31h=16:9 (Analog output only)<br />
*******************************************************<br />
Command code => 92h = <strong>SE</strong>T_OUT_7IRE5_CMD (NTSC only)<br />
Parameter #1 = > Set method: 30h=set by parameter #2 directly, 31h=Increase, 32h=Decrease<br />
When (para#1=30h)<br />
Parameter #2 = > 7.5 IRE on/off: 30h= off, 31h =on<br />
--- Answer ---<br />
Parameter #1 = > Set method: 30h=set by parameter #2 directly, 31h=Increase, 32h=Decrease<br />
Parameter #2 = > 7.5 IRE on/off: 30h= off, 31h =on<br />
*******************************************************<br />
Command code => 93h = ASK_OUT_7IRE5_CMD<br />
Parameter #1 = > NC<br />
--- Answer ----<br />
Parameter #1 = > NC<br />
Parameter #2 = > 7.5 IRE on/off: 30h= off, 31h =on<br />
46