*******************************************************<br />

Command code => 6Ah = <strong>SE</strong>T_BRIGHTNESS_CMD<br />

Parameter #1 = > Set method: 30h=set by parameter #2 directly, 31h=Increase, 32h=Decrease<br />

When (para#1=30h)<br />

Parameter #2 = > Brightness value: -99~+99, default=0(80h)<br />

--- Answer ---<br />

Parameter #1 = > Set method: 30h=set by parameter #2 directly, 31h=Increase, 32h=Decrease<br />

Parameter #2 = > Brightness value: -99~+99, default=0(80h)<br />

*******************************************************<br />

Command code => 6Bh = ASK_BRIGHTNESS_CMD<br />

Parameter #1 = > NC<br />

--- Answer ----<br />

Parameter #1 = > NC<br />

Parameter #2 = >Brightness value: -99~+99, default=0(80h)<br />

*******************************************************<br />

Command code => 6Ch = <strong>SE</strong>T_CONTRAST_CMD<br />

Parameter #1 = > Set method: 30h=set by parameter #2 directly, 31h=Increase, 32h=Decrease<br />

When (para#1=30h)<br />

Parameter #2 = > Contrast value: -99~+99, default=0(80h)<br />

--- Answer ---<br />

Parameter #1 = > Set method: 30h=set by parameter #2 directly, 31h=Increase, 32h=Decrease<br />

Parameter #2 = > Contrast value: -99~+99, default=0(80h)<br />

*******************************************************<br />

Command code => 6Dh = ASK_ CONTRAST_CMD<br />

Parameter #1 = > NC<br />

--- Answer ---<br />

Parameter #1 = > NC<br />

Parameter #2 = > Contrast value: -99~+99 (2’s C) , default=0(80h)<br />

*******************************************************<br />

Command code => 6Eh = <strong>SE</strong>T_ SATURATION _CMD<br />

Parameter #1 = > Set method: 30h=set by parameter #2 directly, 31h=Increase, 32h=Decrease<br />

When (para#1=30h)<br />

Parameter #2 = > Saturation value: -99~+99, default=0(80h)<br />

--- Answer ---<br />

Parameter #1 = > Set method: 30h=set by parameter #2 directly, 31h=Increase, 32h=Decrease<br />

Parameter #2 = > Saturation value: -99~+99, default=0(80h)<br />

*******************************************************<br />

Command code => 6Fh = ASK_ SATURATION _CMD<br />

Parameter #1 = > NC<br />

--- Answer ---<br />

Parameter #1 = > NC<br />

Parameter #2 = > Saturation value: -99~+99, default=0(80h)<br />